@article{EdenZieglerGilbertetal.2015, author = {Eden, Lars and Ziegler, Dirk and Gilbert, Fabian and Fehske, Kai and Fenwick, Annabel and Meffert, Rainer H.}, title = {Significant pain reduction and improved functional outcome after surgery for displaced midshaft clavicular fractures}, series = {Journal of Orthopaedic Surgery and Research}, volume = {10}, journal = {Journal of Orthopaedic Surgery and Research}, number = {190}, doi = {10.1186/s13018-015-0336-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-146357}, year = {2015}, abstract = {Purpose Displaced midshaft clavicular fractures can be treated conservatively as well as operatively by titan elastic nail (TEN) or plate fixation. This survey was performed to evaluate the clinical results of each treatment method and elaborate advantages or possible complications of each modality. Methods Between 2008 and 2013, 102 patients were prospectively included in our study—37 patients for conservative treatment with a rucksack bandage for 4 to 6 weeks, 41 patients for plate osteosynthesis, and 24 for intramedullary stabilization with TEN. Disabilities of the Arm, Shoulder and Hand (DASH), Constant Murley Score (CMS), and visual analog scale (VAS) for pain and function as well as time of invalidity were recorded over a 1-year period. Results The clinical data collected reveals that all three different therapies lead to good or excellent clinical results after 1 year. However, one can observe advantages of operative treatment in comparison to conservative therapy in some characteristics. Conclusion Our data shows that there are several indications where operative treatment has advantages compared to conservative treatment. In special fracture types (Robinson 2B1), TEN gives the best results. Plate fixation is extraordinarily sufficient in pain reduction within the first 5 weeks and indicated in more-part fractures (Robinson 2B2). Nevertheless, conservative treatment is always a good and promising way to treat clavicular fractures, so that individual indications and thorough patient informative talks are inevitable.}, language = {en} } @article{GilbertBoehmEdenetal.2016, author = {Gilbert, Fabian and B{\"o}hm, Dirk and Eden, Lars and Schmalzl, Jonas and Meffert, Rainer H. and K{\"o}stler, Herbert and Weng, Andreas M. and Ziegler, Dirk}, title = {Comparing the MRI-based Goutallier Classification to an experimental quantitative MR spectroscopic fat measurement of the supraspinatus muscle}, series = {BMC Musculoskeletal Disorders}, volume = {17}, journal = {BMC Musculoskeletal Disorders}, number = {355}, doi = {10.1186/s12891-016-1216-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-147788}, year = {2016}, abstract = {Background The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy. Methods MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman's rank correlation. Results Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01). Conclusion The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.}, language = {en} } @article{JordanHoelscherDohtFehskeetal.2015, author = {Jordan, Martin C. and Hoelscher-Doht, Stefanie and Fehske, Kai and Gilbert, Fabian and Jansen, Hendrik and Meffert, Rainer H.}, title = {Bunnell or cross-lock Bunnell suture for tendon repair? Defining the biomechanical role of suture pretension}, series = {Journal of Orthopaedic Surgery and Research}, volume = {10}, journal = {Journal of Orthopaedic Surgery and Research}, number = {192}, doi = {10.1186/s13018-015-0331-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126262}, year = {2015}, abstract = {Background Suture pretension during tendon repair is supposed to increase the resistance to gap formation. However, its effects on the Bunnell suture technique are unknown. The purpose of this study was to determine the biomechanical effects of suture pretension on the Bunnell and cross-lock Bunnell techniques for tendon repair. Methods Eighty porcine hindlimb tendons were randomly assigned to four different tendon repair groups: those repaired with or without suture pretension using either a simple Bunnell or cross-lock Bunnell technique. Pretension was applied as a 10 \% shortening of the sutured tendon. After measuring the cross-sectional diameter at the repair site, static and cyclic biomechanical tests were conducted to evaluate the initial and 5-mm gap formation forces, elongation during cyclic loading, maximum tensile strength, and mode of failure. The suture failure mechanism was also separately assessed fluoroscopically in two tendons that were repaired with steel wire. Results Suture pretension was accompanied by a 10 to 15 \% increase in the tendon diameter at the repair site. Therefore, suture pretension with the Bunnell and cross-lock Bunnell repair techniques noticeably increased the resistance to initial gap formation and 5-mm gap formation. The tension-free cross-lock Bunnell repair demonstrated more resistance to initial and 5-mm gap formation, less elongation, and higher maximum tensile strength than the tension-free Bunnell repair technique. The only difference between the tensioned cross-lock Bunnell and tensioned Bunnell techniques was a larger resistance to 5-mm gap formation with the cross-lock Bunnell technique. Use of the simple instead of cross-lock suture configuration led to failure by suture cut out, as demonstrated fluoroscopically. Conclusion Based on these results, suture pretension decreases gapping and elongation after tendon repair, and those effects are stronger when using a cross-lock, rather than a regular Bunnell suture. However, pretension causes an unfavorable increase in the tendon diameter at the repair site, which may adversely affect wound healing.}, language = {en} } @article{SchmidtJordanHoelscherDohtetal.2014, author = {Schmidt, Karsten and Jordan, Martin C. and H{\"o}lscher-Doht, Stefanie and Jakubietz, Michael G. and Jakubietz, Rafael G. and Meffert, Rainer H.}, title = {Suture material for flexor tendon repair: 3-0 V-Loc versus 3-0 Stratafix in a biomechanical comparison ex vivo}, doi = {10.1186/s13018-014-0072-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-110419}, year = {2014}, abstract = {Background Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materials for primary stability under static and cyclic loading in a biomechanical ex vivo model. Methods Forty fresh porcine flexor digitorum profundus tendons were randomized in two groups. A four-strand modified Kessler suture technique was used to repair the tendon either with a 3-0 V-Loc™ or 3-0 Stratafix™ without a knot. Parameters of interest were mode of failure, 2-mm gap formation force, displacement, stiffness and maximum load under static and cyclic testing. Results The maximum load was 42.3 ± 7.2 for the Stratafix™ group and 50.7 ± 8.8 N for the V-Loc™ group. Thus, the ultimate tensile strength was significantly higher for V-Loc™ (p < 0.05). The 2-mm gap occurred at 24.8 ± 2.04 N in the Stratafix™ group in comparison to 26.5 ± 2.12 N in the V-Loc™ group (n.s.). Displacement was 2.65 ± 0.56 mm in the V-Loc™ group and 2.71 ± 0.59 mm in the Stratafix™ group (n.s.). Stiffness was 4.24 ± 0.68 (N/mm) in the V-Loc™ group and 3.85 ± 0.55 (N/mm) the Stratafix™ group (n.s.). Those measured differences were not significant. Conclusion V-Loc™ demonstrates a higher maximum load in tendon reconstruction. The differences in 2-mm gap formation force, displacement and stiffness were not significant. Hereby, the V-Loc™ has an advantage when used as unidirectional barbed suture for knotless flexor tendon repair.}, language = {en} } @article{HuflageFieberFaerberetal.2022, author = {Huflage, Henner and Fieber, Tabea and F{\"a}rber, Christian and Knarr, Jonas and Veldhoen, Simon and Jordan, Martin C. and Gilbert, Fabian and Bley, Thorsten Alexander and Meffert, Rainer H. and Grunz, Jan-Peter and Schmalzl, Jonas}, title = {Interobserver reliability of scapula fracture classifications in intra- and extra-articular injury patterns}, series = {BMC Musculoskeletal Disorders}, volume = {23}, journal = {BMC Musculoskeletal Disorders}, number = {1}, doi = {10.1186/s12891-022-05146-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-299795}, year = {2022}, abstract = {Background Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and R{\"u}edi (ER) with regard to interobserver reliability and confidence in clinical practice. Methods Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers. Results In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95\% confidence interval [CI] 0.676-0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95\% CI 0.525-0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95\% CI 0.771-0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95\% CI 0.692-0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912). Conclusions The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and R{\"u}edi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.}, language = {en} } @article{FuchsEdenGilbertetal.2021, author = {Fuchs, Konrad F. and Eden, Lars and Gilbert, Fabian and Bernuth, Silvia and Wurmb, Thomas and Meffert, Rainer H. and Jordan, Martin C.}, title = {F{\"u}hrt eine COVID-19 bedingte Ausgangsbeschr{\"a}nkung zu einer Reduktion schwerverletzter Patienten an einem {\"u}berregionalen Traumazentrum?}, series = {Der Unfallchirurg}, volume = {124}, journal = {Der Unfallchirurg}, issn = {0177-5537}, doi = {10.1007/s00113-020-00924-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-232547}, pages = {352-357}, year = {2021}, abstract = {Hintergrund Intensiv- und Beatmungskapazit{\"a}ten sind f{\"u}r die Behandlung COVID-19-erkrankter Patienten essenziell. Unabh{\"a}ngig davon beanspruchen auch schwer verletzte Patienten h{\"a}ufig Intensiv- und Beatmungskapazit{\"a}ten. Daraus ergibt sich folgende Fragestellung: F{\"u}hrt eine Ausgangsbeschr{\"a}nkung zu einer Reduktion schwer verletzter Patienten, und kann hierdurch mit frei werdenden Intensivkapazit{\"a}ten gerechnet werden? Material und Methoden Es erfolgte eine retrospektive Auswertung schwer verletzter Patienten mit einem Injury Severity Score (ISS) ≥16 zwischen dem 17.03.2020 und 30.04.2020 (landesweiter Shutdown) an einem {\"u}berregionalen Traumazentrum. Erfasst wurden der Unfallmechanismus, ISS, Versicherungstr{\"a}ger (BG vs. GKV/PKV), ob es sich um einen dokumentierten Suizidversuch handelte, und ob eine operative Intervention innerhalb der ersten 24 h erforderlich war. Als Kontrollgruppe wurden die Daten des gleichen Zeitraums der Jahre 2018 und 2019 ausgewertet. Ergebnisse Es konnte keine wesentliche Ver{\"a}nderung bez{\"u}glich der Anzahl an schwer verletzten Patienten festgestellt werden (2018 n = 30, 2019 n = 23, 2020 n = 27). Es zeigten sich insgesamt keine deutlichen Ver{\"a}nderungen der absoluten Zahlen bez{\"u}glich der Intensivpflichtigkeit in den ersten 24 h und der Beatmungspflichtigkeit beim Verlassen des Schockraums. Die Anzahl an Patienten, die eine Operation innerhalb der ersten 24 h nach Eintreffen im Schockraum ben{\"o}tigten, war 2020 sogar leicht erh{\"o}ht, jedoch nicht statistisch signifikant. Der durchschnittliche ISS blieb konstant. Bez{\"u}glich der Unfallursache zeigte sich 2020 kein Motorradfahrer, der einen nicht berufsgenossenschaftlich versicherten Unfall erlitt (2018 n = 5, 2019 n = 4, 2020 n = 0). Es wurde 2020 ein erh{\"o}hter Anteil an Arbeitsunf{\"a}llen mit einem ISS ≥16 festgestellt (2018: 10 \%, 2019: 26,1 \%, 2020: 44,4 \%). Diskussion Eine Ausgangsbeschr{\"a}nkung f{\"u}hrte zu keiner Reduktion verletzter- und intensivpflichtiger Patienten am untersuchten Zentrum. Auch unter einer landesweiten Ausgangsbeschr{\"a}nkung muss f{\"u}r dieses Patientenkollektiv eine ausreichende Menge an Intensiv- und OP-Kapazit{\"a}ten vorgehalten werden. Die Best{\"a}tigung dieser Ergebnisse durch Auswertung nationaler Register steht noch aus.}, language = {de} } @article{BernuthVaterFuchsetal.2023, author = {Bernuth, Silvia and Vater, Adrian and Fuchs, Konrad F. and Meffert, Rainer H. and Jakubietz, Rafael G.}, title = {Perfusion changes in perforator-based propeller flaps}, series = {Journal of Reconstructive Microsurgery Open}, volume = {8}, journal = {Journal of Reconstructive Microsurgery Open}, number = {1}, issn = {2377-0813}, doi = {10.1055/a-2086-4988}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-350491}, pages = {e45-e50}, year = {2023}, abstract = {Background  To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible. Methods  A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected. Results  Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day. Conclusion  Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.}, language = {en} } @article{PaulMiedenLeferingetal.2023, author = {Paul, Mila M. and Mieden, Hannah J. and Lefering, Rolf and Kupczyk, Eva K. and Jordan, Martin C. and Gilbert, Fabian and Meffert, Rainer H. and Sir{\´e}n, Anna-Leena and Hoelscher-Doht, Stefanie}, title = {Impact of a femoral fracture on outcome after traumatic brain injury — a matched-pair analysis of the TraumaRegister DGU\(^®\)}, series = {Journal of Clinical Medicine}, volume = {12}, journal = {Journal of Clinical Medicine}, number = {11}, issn = {2077-0383}, doi = {10.3390/jcm12113802}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-319363}, year = {2023}, abstract = {Traumatic brain injury (TBI) is the leading cause of death and disability in polytrauma and is often accompanied by concomitant injuries. We conducted a retrospective matched-pair analysis of data from a 10-year period from the multicenter database TraumaRegister DGU\(^®\) to analyze the impact of a concomitant femoral fracture on the outcome of TBI patients. A total of 4508 patients with moderate to critical TBI were included and matched by severity of TBI, American Society of Anesthesiologists (ASA) risk classification, initial Glasgow Coma Scale (GCS), age, and sex. Patients who suffered combined TBI and femoral fracture showed increased mortality and worse outcome at the time of discharge, a higher chance of multi-organ failure, and a rate of neurosurgical intervention. Especially those with moderate TBI showed enhanced in-hospital mortality when presenting with a concomitant femoral fracture (p = 0.037). The choice of fracture treatment (damage control orthopedics vs. early total care) did not impact mortality. In summary, patients with combined TBI and femoral fracture have higher mortality, more in-hospital complications, an increased need for neurosurgical intervention, and inferior outcome compared to patients with TBI solely. More investigations are needed to decipher the pathophysiological consequences of a long-bone fracture on the outcome after TBI.}, language = {en} } @article{FuchsEdenGilbertetal.2021, author = {Fuchs, Konrad F. and Eden, Lars and Gilbert, Fabian and Bernuth, Silvia and Wurmb, Thomas and Meffert, Rainer H. and Jordan, Martin C.}, title = {F{\"u}hrt eine COVID-19-bedingte Ausgangsbeschr{\"a}nkung zu einer Reduktion schwer verletzter Patienten an einem {\"u}berregionalen Traumazentrum?}, series = {Der Unfallchirurg}, volume = {124}, journal = {Der Unfallchirurg}, number = {5}, doi = {10.1007/s00113-020-00924-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-265268}, pages = {352-357}, year = {2021}, abstract = {Hintergrund Intensiv- und Beatmungskapazit{\"a}ten sind f{\"u}r die Behandlung COVID-19-erkrankter Patienten essenziell. Unabh{\"a}ngig davon beanspruchen auch schwer verletzte Patienten h{\"a}ufig Intensiv- und Beatmungskapazit{\"a}ten. Daraus ergibt sich folgende Fragestellung: F{\"u}hrt eine Ausgangsbeschr{\"a}nkung zu einer Reduktion schwer verletzter Patienten, und kann hierdurch mit frei werdenden Intensivkapazit{\"a}ten gerechnet werden? Material und Methoden Es erfolgte eine retrospektive Auswertung schwer verletzter Patienten mit einem Injury Severity Score (ISS) ≥16 zwischen dem 17.03.2020 und 30.04.2020 (landesweiter Shutdown) an einem {\"u}berregionalen Traumazentrum. Erfasst wurden der Unfallmechanismus, ISS, Versicherungstr{\"a}ger (BG vs. GKV/PKV), ob es sich um einen dokumentierten Suizidversuch handelte, und ob eine operative Intervention innerhalb der ersten 24 h erforderlich war. Als Kontrollgruppe wurden die Daten des gleichen Zeitraums der Jahre 2018 und 2019 ausgewertet. Ergebnisse Es konnte keine wesentliche Ver{\"a}nderung bez{\"u}glich der Anzahl an schwer verletzten Patienten festgestellt werden (2018 n = 30, 2019 n = 23, 2020 n = 27). Es zeigten sich insgesamt keine deutlichen Ver{\"a}nderungen der absoluten Zahlen bez{\"u}glich der Intensivpflichtigkeit in den ersten 24 h und der Beatmungspflichtigkeit beim Verlassen des Schockraums. Die Anzahl an Patienten, die eine Operation innerhalb der ersten 24 h nach Eintreffen im Schockraum ben{\"o}tigten, war 2020 sogar leicht erh{\"o}ht, jedoch nicht statistisch signifikant. Der durchschnittliche ISS blieb konstant. Bez{\"u}glich der Unfallursache zeigte sich 2020 kein Motorradfahrer, der einen nicht berufsgenossenschaftlich versicherten Unfall erlitt (2018 n = 5, 2019 n = 4, 2020 n = 0). Es wurde 2020 ein erh{\"o}hter Anteil an Arbeitsunf{\"a}llen mit einem ISS ≥16 festgestellt (2018: 10 \%, 2019: 26,1 \%, 2020: 44,4 \%). Diskussion Eine Ausgangsbeschr{\"a}nkung f{\"u}hrte zu keiner Reduktion verletzter- und intensivpflichtiger Patienten am untersuchten Zentrum. Auch unter einer landesweiten Ausgangsbeschr{\"a}nkung muss f{\"u}r dieses Patientenkollektiv eine ausreichende Menge an Intensiv- und OP-Kapazit{\"a}ten vorgehalten werden. Die Best{\"a}tigung dieser Ergebnisse durch Auswertung nationaler Register steht noch aus.}, language = {de} } @article{FrischholzBerberichBoecketal.2020, author = {Frischholz, Sebastian and Berberich, Oliver and B{\"o}ck, Thomas and Meffert, Rainer H. and Blunk, Torsten}, title = {Resveratrol counteracts IL-1β-mediated impairment of extracellular matrix deposition in 3D articular chondrocyte constructs}, series = {Journal of Tissue Engineering and Regenerative Medicine}, volume = {14}, journal = {Journal of Tissue Engineering and Regenerative Medicine}, number = {7}, doi = {10.1002/term.3031}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-215471}, pages = {897 -- 908}, year = {2020}, abstract = {When aiming at cell-based therapies in osteoarthritis (OA), proinflammatory conditions mediated by cytokines such as IL-1β need to be considered. In recent studies, the phytoalexin resveratrol (RSV) has exhibited potent anti-inflammatory properties. However, long-term effects on 3D cartilaginous constructs under inflammatory conditions with regard to tissue quality, especially extracellular matrix (ECM) composition, have remained unexplored. Therefore, we employed long-term model cultures for cell-based therapies in an in vitro OA environment and evaluated effects of RSV. Pellet constructs made from expanded porcine articular chondrocytes were cultured with either IL-1β (1-10 ng/ml) or RSV (50 μM) alone, or a cotreatment with both agents. Treatments were applied for 14 days, either directly after pellet formation or after a preculture period of 7 days. Culture with IL-1β (10 ng/ml) decreased pellet size and DNA amount and severely compromised glycosaminoglycan (GAG) and collagen content. Cotreatment with RSV distinctly counteracted the proinflammatory catabolism and led to partial rescue of the ECM composition in both culture systems, with especially strong effects on GAG. Marked MMP13 expression was detected in IL-1β-treated pellets, but none upon RSV cotreatment. Expression of collagen type I was increased upon IL-1β treatment and still observed when adding RSV, whereas collagen type X, indicating hypertrophy, was detected exclusively in pellets treated with RSV alone. In conclusion, RSV can counteract IL-1β-mediated degradation and distinctly improve cartilaginous ECM deposition in 3D long-term inflammatory cultures. Nevertheless, potential hypertrophic effects should be taken into account when considering RSV as cotreatment for articular cartilage repair techniques.}, language = {en} }