@article{SauerGoltzGassenmaieretal.2014, author = {Sauer, Stephanie and Goltz, Jan P. and Gassenmaier, Tobias and Kunz, Andreas S. and Bley, Thorsten A. and Klein, Detlef and Petritsch, Bernhard}, title = {Partial Segmental Thrombosis of the Corpus Cavernosum (PSTCC) diagnosed by contrast-enhanced ultrasound: a case report}, series = {BMC Urology}, volume = {14}, journal = {BMC Urology}, number = {100}, doi = {10.1186/1471-2490-14-100}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126495}, year = {2014}, abstract = {Background Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition. Case presentation We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid. Conclusion PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit.}, language = {en} } @article{FritzVanselowSaueretal.2015, author = {Fritz, Melanie and Vanselow, Jens and Sauer, Nadja and Lamer, Stephanie and Goos, Carina and Siegel, T. Nicolai and Subota, Ines and Schlosser, Andreas and Carrington, Mark and Kramer, Susanne}, title = {Novel insights into RNP granules by employing the trypanosome's microtubule skeleton as a molecular sieve}, series = {Nucleic Acids Research}, journal = {Nucleic Acids Research}, doi = {10.1093/nar/gkv731}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126180}, year = {2015}, abstract = {RNP granules are ribonucleoprotein assemblies that regulate the post-transcriptional fate of mRNAs in all eukaryotes. Their exact function remains poorly understood, one reason for this is that RNP granule purification has not yet been achieved. We have exploited a unique feature of trypanosomes to prepare a cellular fraction highly enriched in starvation stress granules. First, granules remain trapped within the cage-like, subpellicular microtubule array of the trypanosome cytoskeleton while soluble proteins are washed away. Second, the microtubules are depolymerized and the granules are released. RNA sequencing combined with single molecule mRNA FISH identified the short and highly abundant mRNAs encoding ribosomal mRNAs as being excluded from granules. By mass spectrometry we have identified 463 stress granule candidate proteins. For 17/49 proteins tested by eYFP tagging we have confirmed the localization to granules, including one phosphatase, one methyltransferase and two proteins with a function in trypanosome life-cycle regulation. The novel method presented here enables the unbiased identification of novel RNP granule components, paving the way towards an understanding of RNP granule function.}, language = {en} } @article{HaackBaikerSchlegeletal.2021, author = {Haack, Stephanie and Baiker, Sarah and Schlegel, Jan and Sauer, Markus and Sparwasser, Tim and Langenhorst, Daniela and Beyersdorf, Niklas}, title = {Superagonistic CD28 stimulation induces IFN-γ release from mouse T helper 1 cells in vitro and in vivo}, series = {European Journal of Immunology}, volume = {51}, journal = {European Journal of Immunology}, number = {3}, doi = {10.1002/eji.202048803}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-239028}, pages = {738 -- 741}, year = {2021}, abstract = {Like human Th1 cells, mouse Th1 cells also secrete IFN-γ upon stimulation with a superagonistic anti-CD28 monoclonal antibody (CD28-SA). Crosslinking of the CD28-SA via FcR and CD40-CD40L interactions greatly increased IFN-γ release. Our data stress the utility of the mouse as a model organism for immune responses in humans.}, language = {en} } @article{DiessnerAndersHerbertetal.2023, author = {Diessner, Joachim and Anders, Laura and Herbert, Saskia and Kiesel, Matthias and Bley, Thorsten and Schlaiss, Tanja and Sauer, Stephanie and W{\"o}ckel, Achim and Bartmann, Catharina}, title = {Evaluation of different imaging modalities for axillary lymph node staging in breast cancer patients to provide a personalized and optimized therapy algorithm}, series = {Journal of Cancer Research and Clinical Oncology}, volume = {149}, journal = {Journal of Cancer Research and Clinical Oncology}, number = {7}, doi = {10.1007/s00432-022-04221-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324047}, pages = {3457-3467}, year = {2023}, abstract = {Purpose The reliable detection of tumor-infiltrated axillary lymph nodes for breast cancer [BC] patients plays a decisive role in further therapy. We aimed to find out whether cross-sectional imaging techniques could improve sensitivity for pretherapeutic axillary staging in nodal-positive BC patients compared to conventional imaging such as mammography and sonography. Methods Data for breast cancer patients with tumor-infiltrated axillary lymph nodes having received surgery between 2014 and 2020 were included in this study. All examinations (sonography, mammography, computed tomography [CT] and magnetic resonance imaging [MRI]) were interpreted by board-certified specialists in radiology. The sensitivity of different imaging modalities was calculated, and binary logistic regression analyses were performed to detect variables influencing the detection of positive lymph nodes. Results All included 382 breast cancer patients had received conventional imaging, while 52.61\% of the patients had received cross-sectional imaging. The sensitivity of the combination of all imaging modalities was 68.89\%. The combination of MRI and CT showed 63.83\% and the combination of sonography and mammography showed 36.11\% sensitivity. Conclusion We could demonstrate that cross-sectional imaging can improve the sensitivity of the detection of tumor-infiltrated axillary lymph nodes in breast cancer patients. Only the safe detection of these lymph nodes at the time of diagnosis enables the evaluation of the response to neoadjuvant therapy, thereby allowing access to prognosis and improving new post-neoadjuvant therapies.}, language = {en} } @article{ZacherWollankaSaueretal.2023, author = {Zacher, Magdalena and Wollanka, Nele and Sauer, Christina and Haßtenteufel, Kathrin and Wallwiener, Stephanie and Wallwiener, Markus and Maatouk, Imad}, title = {Prenatal paternal depression, anxiety, and somatic symptom burden in different risk samples: an explorative study}, series = {Archives of Gynecology and Obstetrics}, volume = {307}, journal = {Archives of Gynecology and Obstetrics}, number = {4}, doi = {10.1007/s00404-022-06612-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324465}, pages = {1255-1263}, year = {2023}, abstract = {Purpose Growing evidence implies that transition to parenthood triggers symptoms of mental burden not only in women but likewise in men, especially in high-risk pregnancies. This is the first study that examined and compared the prevalence rates of depression, anxiety, and somatic symptom burden of expectant fathers who face different risk situations during pregnancy. Methods Prevalence rates of paternal depression (Edinburgh postnatal depression scale), anxiety (generalized anxiety disorder seven), and somatic symptom burden (somatic symptom scale eight) were examined in two risk samples and one control group in the third trimester of their partners' pregnancy: risk sample I (n = 41) consist of expectant fathers whose partners were prenatally hospitalized due to medical complications; risk sample II (n = 52) are fathers whose partners were prenatally mentally distressed; and control group (n = 70) are those non-risk pregnancies. Results On a purely descriptive level, the data display a trend of higher symptom burden of depression, anxiety, and somatic symptoms in the two risk samples, indicating that expectant fathers, whose pregnant partners were hospitalized or suffered prenatal depression, were more prenatally distressed. Exploratory testing of group differences revealed an almost three times higher prevalence rate of anxiety in fathers whose partner was hospitalized (12.2\%) compared to those non-risks (4.3\%). Conclusion Results underline the need for screening implementations for paternal prenatal psychological distress, as well as specific prevention and treatment programs, especially for fathers in risk situations, such as their pregnant partners' prenatal hospitalization. The study was registered with the German clinical trials register (DRKS00020131) on 2019/12/09.}, language = {en} } @article{HuflageKunzHendeletal.2023, author = {Huflage, Henner and Kunz, Andreas Steven and Hendel, Robin and Kraft, Johannes and Weick, Stefan and Razinskas, Gary and Sauer, Stephanie Tina and Pennig, Lenhard and Bley, Thorsten Alexander and Grunz, Jan-Peter}, title = {Obesity-related pitfalls of virtual versus true non-contrast imaging — an intraindividual comparison in 253 oncologic patients}, series = {Diagnostics}, volume = {13}, journal = {Diagnostics}, number = {9}, issn = {2075-4418}, doi = {10.3390/diagnostics13091558}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-313519}, year = {2023}, abstract = {Objectives: Dual-source dual-energy CT (DECT) facilitates reconstruction of virtual non-contrast images from contrast-enhanced scans within a limited field of view. This study evaluates the replacement of true non-contrast acquisition with virtual non-contrast reconstructions and investigates the limitations of dual-source DECT in obese patients. Materials and Methods: A total of 253 oncologic patients (153 women; age 64.5 ± 16.2 years; BMI 26.6 ± 5.1 kg/m\(^2\)) received both multi-phase single-energy CT (SECT) and DECT in sequential staging examinations with a third-generation dual-source scanner. Patients were allocated to one of three BMI clusters: non-obese: <25 kg/m\(^2\) (n = 110), pre-obese: 25-29.9 kg/m\(^2\) (n = 73), and obese: >30 kg/m\(^2\) (n = 70). Radiation dose and image quality were compared for each scan. DECT examinations were evaluated regarding liver coverage within the dual-energy field of view. Results: While arterial contrast phases in DECT were associated with a higher CTDI\(_{vol}\) than in SECT (11.1 vs. 8.1 mGy; p < 0.001), replacement of true with virtual non-contrast imaging resulted in a considerably lower overall dose-length product (312.6 vs. 475.3 mGy·cm; p < 0.001). The proportion of DLP variance predictable from patient BMI was substantial in DECT (R\(^2\) = 0.738) and SECT (R\(^2\) = 0.620); however, DLP of SECT showed a stronger increase in obese patients (p < 0.001). Incomplete coverage of the liver within the dual-energy field of view was most common in the obese subgroup (17.1\%) compared with non-obese (0\%) and pre-obese patients (4.1\%). Conclusion: DECT facilitates a 30.8\% dose reduction over SECT in abdominal oncologic staging examinations. Employing dual-source scanner architecture, the risk for incomplete liver coverage increases in obese patients.}, language = {en} } @article{HuflageGrunzPatzeretal.2023, author = {Huflage, Henner and Grunz, Jan-Peter and Patzer, Theresa Sophie and Pannenbecker, Pauline and Feldle, Philipp and Sauer, Stephanie Tina and Petritsch, Bernhard and Erg{\"u}n, S{\"u}leyman and Bley, Thorsten Alexander and Kunz, Andreas Steven}, title = {Potential of unenhanced ultra-low-dose abdominal photon-counting CT with tin filtration: a cadaveric study}, series = {Diagnostics}, volume = {13}, journal = {Diagnostics}, number = {4}, issn = {2075-4418}, doi = {10.3390/diagnostics13040603}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-304122}, year = {2023}, abstract = {Objectives: This study investigated the feasibility and image quality of ultra-low-dose unenhanced abdominal CT using photon-counting detector technology and tin prefiltration. Materials and Methods: Employing a first-generation photon-counting CT scanner, eight cadaveric specimens were examined both with tin prefiltration (Sn 100 kVp) and polychromatic (120 kVp) scan protocols matched for radiation dose at three different levels: standard-dose (3 mGy), low-dose (1 mGy) and ultra-low-dose (0.5 mGy). Image quality was evaluated quantitatively by means of contrast-to-noise-ratios (CNR) with regions of interest placed in the renal cortex and subcutaneous fat. Additionally, three independent radiologists performed subjective evaluation of image quality. The intraclass correlation coefficient was calculated as a measure of interrater reliability. Results: Irrespective of scan mode, CNR in the renal cortex decreased with lower radiation dose. Despite similar mean energy of the applied x-ray spectrum, CNR was superior for Sn 100 kVp over 120 kVp at standard-dose (17.75 ± 3.51 vs. 14.13 ± 4.02), low-dose (13.99 ± 2.6 vs. 10.68 ± 2.17) and ultra-low-dose levels (8.88 ± 2.01 vs. 11.06 ± 1.74) (all p ≤ 0.05). Subjective image quality was highest for both standard-dose protocols (score 5; interquartile range 5-5). While no difference was ascertained between Sn 100 kVp and 120 kVp examinations at standard and low-dose levels, the subjective image quality of tin-filtered scans was superior to 120 kVp with ultra-low radiation dose (p < 0.05). An intraclass correlation coefficient of 0.844 (95\% confidence interval 0.763-0.906; p < 0.001) indicated good interrater reliability. Conclusions: Photon-counting detector CT permits excellent image quality in unenhanced abdominal CT with very low radiation dose. Employment of tin prefiltration at 100 kVp instead of polychromatic imaging at 120 kVp increases the image quality even further in the ultra-low-dose range of 0.5 mGy.}, language = {en} }