@article{DuekingGiessingFrenkeletal.2020, author = {D{\"u}king, Peter and Giessing, Laura and Frenkel, Marie Ottilie and Koehler, Karsten and Holmberg, Hans-Christer and Sperlich, Billy}, title = {Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study}, series = {JMIR mhealth and uhealth}, volume = {8}, journal = {JMIR mhealth and uhealth}, number = {5}, doi = {10.2196/16716}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229413}, year = {2020}, abstract = {Background: Physical activity reduces the incidences of noncommunicable diseases, obesity, and mortality, but an inactive lifestyle is becoming increasingly common. Innovative approaches to monitor and promote physical activity are warranted. While individual monitoring of physical activity aids in the design of effective interventions to enhance physical activity, a basic prerequisite is that the monitoring devices exhibit high validity. Objective: Our goal was to assess the validity of monitoring heart rate (HR) and energy expenditure (EE) while sitting or performing light-to-vigorous physical activity with 4 popular wrist-worn wearables (Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa). Methods: While wearing the 4 different wearables, 25 individuals performed 5 minutes each of sitting, walking, and running at different velocities (ie, 1.1 m/s, 1.9 m/s, 2.7 m/s, 3.6 m/s, and 4.1 m/s), as well as intermittent sprints. HR and EE were compared to common criterion measures: Polar-H7 chest belt for HR and indirect calorimetry for EE. Results: While monitoring HR at different exercise intensities, the standardized typical errors of the estimates were 0.09-0.62, 0.13-0.88, 0.62-1.24, and 0.47-1.94 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 0.9\%-4.3\%, 2.2\%-6.7\%, 2.9\%-9.2\%, and 4.1\%-19.1\%, respectively, for the 4 wearables. While monitoring EE at different exercise intensities, the standardized typical errors of the estimates were 0.34-1.84, 0.32-1.33, 0.46-4.86, and 0.41-1.65 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 13.5\%-27.1\%, 16.3\%-28.0\%, 15.9\%-34.5\%, and 8.0\%-32.3\%, respectively. Conclusions: The Apple Watch Series 4 provides the highest validity (ie, smallest error rates) when measuring HR while sitting or performing light-to-vigorous physical activity, followed by the Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, in that order. The Apple Watch Series 4 and Polar Vantage V are suitable for valid HR measurements at the intensities tested, but HR data provided by the Garmin Fenix 5 and Fitbit Versa should be interpreted with caution due to higher error rates at certain intensities. None of the 4 wrist-worn wearables should be employed to monitor EE at the intensities and durations tested."}, language = {en} } @article{EngelWagnerSchelhornetal.2019, author = {Engel, Florian A. and Wagner, Matthias Oliver and Schelhorn, Franziska and Deubert, Felix and Leutzsch, Sascha and Stolz, Alexander and Sperlich, Billy}, title = {Classroom-Based Micro-Sessions of Functional High-Intensity Circuit Training Enhances Functional Strength but Not Cardiorespiratory Fitness in School Children — A Feasibility Study}, series = {Frontiers in Public Health}, volume = {7}, journal = {Frontiers in Public Health}, number = {291}, issn = {2296-2565}, doi = {10.3389/fpubh.2019.00291}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-195669}, year = {2019}, abstract = {The present study assessed the short-term effect of 6 min classroom-based micro-sessions of multi-joint functional high-intensity circuit training (FunctionalHIIT) performed by students during regular classes on parameters related to functional strength and cardiorespiratory fitness. In this randomized controlled 4-week study, 17 students (11 male; 6 female; age: 11.6 ± 0.2 years) performed 6 min of FunctionalHIIT (targeting >17 on the Borg scale) 4 days per week during regular school classes and 18 students (11 male; 7 female; age: 11.7 ± 0.3 years) served as control group (CG) without any additional in-class physical activity. The FunctionalHIIT group completed 86\% of all planned sessions (mean duration: 6.0 ± 1.5 min) with a mean RPE of 17.3 ± 2.1. Body height, mass and BMI did not differ between the groups at baseline or between pre- and post-testing (p > 0.05; eta2 ≤ 0.218). The performances in lateral jumping (p < 0.000; part eta2 = 0.382; Δ\% 4.6 ± 8.6), sit-ups (p < 0.000; part eta2 = 0.485; Δ\% 3.1 ± 8.6) and 20-m sprints (p < 0.000; part eta2 = 0.691; Δ\% 15.8 ± 5.4) improved in both groups with greater increase following FunctionalHIIT. No baseline differences and no interaction effects occurred in performance of 6 min run, flexibility, push-ups, balance, and long jump. Classroom-based FunctionalHIIT sessions, performed 4 days per week during 4 weeks did not improve variables related to aerobic endurance performance but enhanced certain parameters of functional strength in schoolchildren. As time is limited in the educational system of schools, FunctionalHIIT during regular school classes could offer a new perspective for increasing functional strength in schoolchildren.}, language = {en} } @article{BeckerSperlichZinneretal.2020, author = {Becker, Manuel and Sperlich, Billy and Zinner, Christoph and Achtzehn, Silvia}, title = {Intra-Individual and Seasonal Variation of Selected Biomarkers for Internal Load Monitoring in U-19 Soccer Players}, series = {Frontiers in Physiology}, volume = {11}, journal = {Frontiers in Physiology}, number = {838}, issn = {1664-042X}, doi = {10.3389/fphys.2020.00838}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-209616}, year = {2020}, abstract = {The aim of this study was to investigate inter-day and -week as well as intra- and inter-individual variation of selected biomarkers in high-performance youth soccer players to assist practitioners interpreting player's internal load to counteract underperformance and unwanted health risks. Eleven male youth soccer players were tested multiple times during two 3-week periods at midpoint (3-wkmid) and at the end (3-wkend) of the first half of a German under-19 1. Bundesliga season. The levels of creatine kinase (CK), urea, and C-reactive protein (CRP) were measured during 3-wkmid and 3-wkend each Monday, Wednesday, and Friday. In 3-wkmid the CK median was 14\% higher (241 vs. 212 U/L) compared to 3-wkend (P = 0.26, ES = 0.16). Overall, the medians of CK, urea (P = 0.59, ES = 0.08), and CRP (P = 0.56, ES = 0.10) during 3-wkmid did not differ to the values of 3-wkend. Daily coefficient of variations (CVs) ranged from 22 to 71\% (CK), 17 to 37\% (urea), and 9 to 164\% (CRP). Individual medians ranged from 101 to 350 U/L (CK), 23 to 50 mg/dL (urea), and 0.6 to 1.1 mg/L (CRP). High intra-individual variability was demonstrated by large intra-individual CVs (medians: CK 50\%, urea 18\%, and CRP 45\%). Our data show (i) large inter-day and inter-week variability of all biomarkers, depending on the external load and (ii) considerable inter- and intra-individual parameter variations. Creatine kinase concentrations could sensitively reflect soccer-specific loads during the season.}, language = {en} } @article{McIlroyPassfieldHolmbergetal.2021, author = {McIlroy, Benjamin and Passfield, Louis and Holmberg, Hans-Christer and Sperlich, Billy}, title = {Virtual training of endurance cycling - A summary of strengths, weaknesses, opportunities and threats}, series = {Frontiers in Sports and Active Living}, volume = {3}, journal = {Frontiers in Sports and Active Living}, doi = {10.3389/fspor.2021.631101}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-258876}, year = {2021}, abstract = {Virtual online training has emerged as one of the top 20 worldwide fitness trends for 2021 and continues to develop rapidly. Although this allows the cycling community to engage in virtual training and competition, critical evaluation of virtual training platforms is limited. Here, we discuss the strengths, weaknesses, opportunities and threats associated with virtual training technology and cycling in an attempt to enhance awareness of such aspects. Strengths include immersive worlds, innovative drafting mechanics, and versatility. Weaknesses include questionable data accuracy, inadequate strength and reliability of power-speed algorithms. Opportunities exist for expanding strategic partnerships with major cycling races, brands, and sponsors and improving user experience with the addition of video capture and "e-coaching." Threats are present in the form of cheating during competition, and a lack of uptake and acceptance by a broader community.}, language = {en} } @article{DavidsonDuekingZinneretal.2020, author = {Davidson, Padraig and D{\"u}king, Peter and Zinner, Christoph and Sperlich, Billy and Hotho, Andreas}, title = {Smartwatch-Derived Data and Machine Learning Algorithms Estimate Classes of Ratings of Perceived Exertion in Runners: A Pilot Study}, series = {Sensors}, volume = {20}, journal = {Sensors}, number = {9}, issn = {1424-8220}, doi = {10.3390/s20092637}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-205686}, year = {2020}, abstract = {The rating of perceived exertion (RPE) is a subjective load marker and may assist in individualizing training prescription, particularly by adjusting running intensity. Unfortunately, RPE has shortcomings (e.g., underreporting) and cannot be monitored continuously and automatically throughout a training sessions. In this pilot study, we aimed to predict two classes of RPE (≤15 "Somewhat hard to hard" on Borg's 6-20 scale vs. RPE >15 in runners by analyzing data recorded by a commercially-available smartwatch with machine learning algorithms. Twelve trained and untrained runners performed long-continuous runs at a constant self-selected pace to volitional exhaustion. Untrained runners reported their RPE each kilometer, whereas trained runners reported every five kilometers. The kinetics of heart rate, step cadence, and running velocity were recorded continuously ( 1 Hz ) with a commercially-available smartwatch (Polar V800). We trained different machine learning algorithms to estimate the two classes of RPE based on the time series sensor data derived from the smartwatch. Predictions were analyzed in different settings: accuracy overall and per runner type; i.e., accuracy for trained and untrained runners independently. We achieved top accuracies of 84.8 \% for the whole dataset, 81.8 \% for the trained runners, and 86.1 \% for the untrained runners. We predict two classes of RPE with high accuracy using machine learning and smartwatch data. This approach might aid in individualizing training prescriptions.}, language = {en} } @article{DuekingTaflerWallmannSperlichetal.2020, author = {D{\"u}king, Peter and Tafler, Marie and Wallmann-Sperlich, Birgit and Sperlich, Billy and Kleih, Sonja}, title = {Behavior Change Techniques in Wrist-Worn Wearables to Promote Physical Activity: Content Analysis}, series = {JMIR Mhealth and Uhealth}, volume = {8}, journal = {JMIR Mhealth and Uhealth}, number = {11}, doi = {10.2196/20820}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230556}, year = {2020}, abstract = {Background: Decreasing levels of physical activity (PA) increase the incidences of noncommunicable diseases, obesity, and mortality. To counteract these developments, interventions aiming to increase PA are urgently needed. Mobile health (mHealth) solutions such as wearable sensors (wearables) may assist with an improvement in PA. Objective: The aim of this study is to examine which behavior change techniques (BCTs) are incorporated in currently available commercial high-end wearables that target users' PA behavior. Methods: The BCTs incorporated in 5 different high-end wearables (Apple Watch Series 3, Garmin V{\´i}voactive 3, Fitbit Versa, Xiaomi Amazfit Stratos 2, and Polar M600) were assessed by 2 researchers using the BCT Taxonomy version 1 (BCTTv1). Effectiveness of the incorporated BCTs in promoting PA behavior was assessed by a content analysis of the existing literature. Results: The most common BCTs were goal setting (behavior), action planning, review behavior goal(s), discrepancy between current behavior and goal, feedback on behavior, self-monitoring of behavior, and biofeedback. Fitbit Versa, Garmin V{\´i}voactive 3, Apple Watch Series 3, Polar M600, and Xiaomi Amazfit Stratos 2 incorporated 17, 16, 12, 11, and 11 BCTs, respectively, which are proven to effectively promote PA. Conclusions: Wearables employ different numbers and combinations of BCTs, which might impact their effectiveness in improving PA. To promote PA by employing wearables, we encourage researchers to develop a taxonomy specifically designed to assess BCTs incorporated in wearables. We also encourage manufacturers to customize BCTs based on the targeted populations.}, language = {en} } @article{DuekingHothoHolmbergetal.2016, author = {D{\"u}king, Peter and Hotho, Andreas and Holmberg, Hans-Christer and Fuss, Franz Konstantin and Sperlich, Billy}, title = {Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable Technologies}, series = {Frontiers in Physiology}, volume = {7}, journal = {Frontiers in Physiology}, number = {71}, doi = {10.3389/fphys.2016.00071}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-165516}, year = {2016}, abstract = {Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables) provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete's training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health.}, language = {en} } @article{TrabelsiAmmarBoukhrisetal.2020, author = {Trabelsi, Khaled and Ammar, Achraf and Boukhris, Omar and Glenn, Jordan M. and Bott, Nick and Stannard, Stephen R. and Engel, Florian A. and Sperlich, Billy and Garbarino, Sergio and Bragazzi, Nicola L. and Shephard, Roy J. and Chtourou, Hamdi}, title = {Effects of Ramadan observance on dietary intake and body composition of adolescent athletes: systematic review and meta-analysis}, series = {Nutrients}, volume = {12}, journal = {Nutrients}, number = {6}, issn = {2072-6643}, doi = {10.3390/nu12061574}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-205856}, year = {2020}, abstract = {To evaluate the effects of Ramadan observance on dietary intake, body mass and body composition of adolescent athletes (design: systematic review and meta-analysis; data sources: PubMed and Web of Science; eligibility criteria for selecting studies: single-group, pre-post, with or without control-group studies, conducted in athletes aged <19 years, training at least 3 times/week, and published in any language before 12 February 2020). Studies assessing body mass and/or body composition and/or dietary intake were deemed eligible. The methodological quality was assessed using 'QualSyst'. Of the twelve selected articles evaluating body mass and/or body composition, one was of strong quality and eleven were rated as moderate. Ten articles evaluated dietary intake; four were rated as strong and the remaining moderate in quality. Continuation of training during Ramadan did not change body mass from before to the first week (trivial effect size (ES) = -0.011, p = 0.899) or from before to the fourth week of Ramadan (trivial ES = 0.069, p = 0.277). Additionally, Ramadan observance did not change body fat content from before to the first week (trivial ES = -0.005, p = 0.947) and from before to the fourth week of Ramadan (trivial ES = -0.057, p = 0.947). Lean body mass remained unchanged from before to the fourth week of Ramadan (trivial ES = -0.025, p = 0.876). Dietary data showed the intake of energy (small ES = -0.272, p = 0.182), fat (trivial ES = 0.044, p = 0.842), protein (trivial ES = 0.069, p = 0.720), carbohydrate (trivial ES = 0.075, p = 0.606) and water (trivial ES = -0.115, p = 0.624) remained essentially unchanged during as compared to before Ramadan. Continued training of adolescent athletes at least three times/week during Ramadan observance has no effect on body mass, body composition or dietary intake.}, language = {en} } @article{DuekingAchtzehnHolmbergetal.2018, author = {D{\"u}king, Peter and Achtzehn, Silvia and Holmberg, Hans-Christer and Sperlich, Billy}, title = {Integrated framework of load monitoring by a combination of smartphone applications, wearables and point-of-care testing provides feedback that allows individual responsive adjustments to activities of daily living}, series = {Sensors}, volume = {18}, journal = {Sensors}, number = {5}, doi = {10.3390/s18051632}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-176506}, pages = {1632}, year = {2018}, abstract = {Athletes schedule their training and recovery in periods, often utilizing a pre-defined strategy. To avoid underperformance and/or compromised health, the external load during training should take into account the individual's physiological and perceptual responses. No single variable provides an adequate basis for planning, but continuous monitoring of a combination of several indicators of internal and external load during training, recovery and off-training as well may allow individual responsive adjustments of a training program in an effective manner. From a practical perspective, including that of coaches, monitoring of potential changes in health and performance should ideally be valid, reliable and sensitive, as well as time-efficient, easily applicable, non-fatiguing and as non-invasive as possible. Accordingly, smartphone applications, wearable sensors and point-of-care testing appear to offer a suitable monitoring framework allowing responsive adjustments to exercise prescription. Here, we outline 24-h monitoring of selected parameters by these technologies that (i) allows responsive adjustments of exercise programs, (ii) enhances performance and/or (iii) reduces the risk for overuse, injury and/or illness.}, language = {en} } @article{WallmannSperlichBippBuckschetal.2017, author = {Wallmann-Sperlich, Birgit and Bipp, Tanja and Bucksch, Jens and Froboese, Ingo}, title = {Who uses height-adjustable desks? - Sociodemographic, health-related, and psycho-social variables of regular users}, series = {International Journal of Behavioral Nutrition and Physical Activity}, volume = {14}, journal = {International Journal of Behavioral Nutrition and Physical Activity}, number = {26}, doi = {10.1186/s12966-017-0480-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-157888}, year = {2017}, abstract = {Background: Sit-to-stand height-adjustable desks (HAD) may promote workplace standing, as long as workers use them on a regular basis. The aim of this study was to investigate (i) how common HAD in German desk-based workers are, and how frequently HADs are used, (ii) to identify sociodemographic, health-related, and psycho-social variables of workday sitting including having a HAD, and (iii) to analyse sociodemographic, health-related, and psycho-social variables of users and non-users of HADs. Methods: A cross-sectional sample of 680 participants (51.9\% men; 41.0 ± 13.1 years) in a desk-based occupation was interviewed by telephone about their occupational sitting and standing proportions, having and usage of a HAD, and answered questions concerning psycho-social variables of occupational sitting. The proportion of workday sitting was calculated for participants having an HAD (n = 108) and not-having an HAD (n = 573), as well as for regular users of HAD (n = 54), and irregular/non-users of HAD (n = 54). Linear regressions were conducted to calculate associations between socio-demographic, health-related, psychosocial variables and having/not having an HAD, and the proportion of workday sitting. Logistic regressions were executed to examine the association of mentioned variables and participants' usage of HADs. Results: Sixteen percent report that they have an HAD, and 50\% of these report regular use of HAD. Having an HAD is not a correlate of the proportion of workday sitting. Further analysis restricted to participants having available a HAD highlights that only the 'perceived advantages of sitting less' was significantly associated with HAD use in the fully adjusted model (OR 1.75 [1.09; 2.81], p < 0.05). Conclusions: The present findings indicate that accompanying behavioral action while providing an HAD is promising to increase the regular usage of HAD. Hence, future research needs to address the specificity of behavioral actions in order to enhance regular HAD use, and needs to give more fundamental insights into these associations.}, language = {en} }