@article{GilbertKleinWengetal.2017, author = {Gilbert, Fabian and Klein, Detlef and Weng, Andreas Max and K{\"o}stler, Herbert and Schmitz, Benedikt and Schmalzl, Jonas and B{\"o}hm, Dirk}, title = {Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration}, series = {BMC Muscoskeletal Disorders}, volume = {18}, journal = {BMC Muscoskeletal Disorders}, number = {549}, doi = {10.1186/s12891-017-1911-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-159378}, year = {2017}, abstract = {Background: Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly. Methods: Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson's correlation test. Results: Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0\% to 77.41\% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle. Conclusion: These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.}, language = {en} } @article{JakubietzJakubietzMeffertetal.2017, author = {Jakubietz, Michael G. and Jakubietz, Rafael G. and Meffert, Rainer H. and Schmidt, Karsten and Zahn, Robert K.}, title = {Biomechanical properties of first dorsal extensor compartment regarding adequacy as a bone-ligament-bone graft}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {7}, doi = {10.1097/GOX.0000000000001397}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158851}, pages = {e1397}, year = {2017}, abstract = {Background: Bone-ligament-bone grafts for reconstruction of the scapholunate ligament are a valuable tool to prevent disease progression to carpal collapse. Locally available grafts do not require an additional donor site. The first extensor compartment was evaluated biomechanically regarding its possible use as an autograft. Methods: Twelve native fresh-frozen, human cadaver specimens were tested by applying axial tension in a Zwick Roell machine. Load to failure, transplant elongation, and bony avulsion were recorded. The load to failure was quantitated in newtons (N) and the displacement in length (millimeters). Parameters were set at distinct points as start of tension, 1 mm stretch and 1.5 mm dissociation, failure and complete tear, and were evaluated under magnified visual control. Although actual failure occurred at higher tension, functional failure was defined at a stretch of 1.5 mm. Results: Mean load at 1 mm elongation was 44.1 ± 28 N and at 1.5 mm elongation 57.5 ± 42 N. Failure occurred at 111 ± 83.1 N. No avulsion of the bony insertion was observed. Half the transplants failed in the central part of the ligament, while the rest failed near the insertion but not at the insertion itself. Analysis of tension strength displayed a wide range from 3.8 to 83.7 N/mm at a mean of 33.4 ± 28.4 N/mm. Conclusions: The biomechanical tensile properties of the first dorsal extensor compartment are similar to those of the dorsal part of the scapholunate ligament. A transplant with a larger bone stock and a longer ligament may display an advantage, as insertion is possible in the dorsal, easily accessible part of the carpal bones rather than in the ar{\^e}te-like region adjacent to the insertion of the scapholunate ligament. In this study, 1.5 mm lengthening of the bone-ligament-bone transplant was defined as clinical failure, as such elongation will cause severe gapping and is considered as failure of the transplant.}, language = {en} } @article{JakubietzNickelNeshkovaetal.2017, author = {Jakubietz, Rafael G. and Nickel, Aljoscha and Neshkova, Iva and Schmidt, Karsten and Gilbert, Fabian and Meffert, Rainer H. and Jakubietz, Michael G.}, title = {Long-term patency of twisted vascular pedicles in perforator-based propeller flaps}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {10}, doi = {10.1097/GOX.0000000000001544}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158870}, pages = {e1544}, year = {2017}, abstract = {Background: Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps. Methods: In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap. Results: The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss. Conclusions: The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.}, language = {en} } @article{JakubietzJakubietzMeffertetal.2017, author = {Jakubietz, Rafael G. and Jakubietz, Michael G. and Meffert, Rainer H. and Schmidt, Karsten}, title = {Multiple-level replantation in elderly patients: risk versus benefit}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {4}, doi = {10.1097/GOX.0000000000001313}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158443}, pages = {e1313}, year = {2017}, abstract = {Multiple-level amputations of the upper extremity represent a surgical challenge generally only attempted in young patients. This case demonstrates a successful replantation in an elderly woman. The postoperative course was complicated by disseminated intravascular coagulopathy most likely due to inadequate resuscitation. Hand trauma is often underestimated in its general severity. Upper extremity amputations need to be handled similar to polytraumatized patients.}, language = {en} } @article{ArnholdtGilbertBlanketal.2017, author = {Arnholdt, J{\"o}rg and Gilbert, Fabian and Blank, Marc and Papazoglou, Jannis and Rudert, Maximilian and N{\"o}th, Ulrich and Steinert, Andre F.}, title = {The Mayo conservative hip: complication analysis and management of the first 41 cases performed at a University level 1 department}, series = {BMC Muskoskeletal Disorders}, volume = {18}, journal = {BMC Muskoskeletal Disorders}, number = {250}, doi = {10.1186/s12891-017-1613-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-157812}, year = {2017}, abstract = {Background: To prevent bone loss in hip arthroplasty, several short stem systems have been developed, including the Mayo conservative hip system. While there is a plethora of data confirming inherent advantages of these systems, only little is known about potential complications, especially when surgeons start to use these systems. Methods: In this study, we present a retrospective analysis of the patients' outcome, complications and the complication management of the first 41 Mayo conservative hips performed in 37 patients. For this reason, functional scores, radiographic analyses, peri- and postoperative complications were assessed at an average follow-up of 35 months. Results: The overall HHS improved from 61.2 pre-operatively to 85.6 post-operatively. The German Extra Short Musculoskeletal Function Assessment Questionnaire (XSFMA-D) improved from 30.3 pre-operatively to 12.2 post-operatively. The most common complication was an intraoperative non-displaced fracture of the proximal femur observed in 5 cases (12.1\%). Diabetes, higher BMI and older ages were shown to be risk factors for these intra-operative periprosthetic fractures (p < 0.01). Radiographic analysis revealed a good offset reconstruction in all cases. Conclusion: In our series, a high complication rate with 12.1\% of non-displaced proximal femoral fractures was observed using the Mayo conservative hip. This may be attributed to the flat learning curve of the system or the inherent patient characteristics of the presented cohort."}, language = {en} } @article{JakubietzMeffertSchmidtetal.2017, author = {Jakubietz, Michael G. and Meffert, Rainer H. and Schmidt, Karsten and Gruenert, Joerg G. and Jakubietz, Rafael G.}, title = {Acute A4 Pulley Reconstruction with a First Extensor Compartment Onlay Graft}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {6}, doi = {10.1097/GOX.0000000000001361}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158057}, pages = {e1361}, year = {2017}, abstract = {Background: The integrity of the flexor tendon pulley apparatus is crucial for unimpaired function of the digits. Although secondary reconstruction is an established procedure in multi-pulley injuries, acute reconstruction of isolated, closed pulley ruptures is a rare occurrence. There are 3 factors influencing the functional outcome of a reconstruction: gapping distance between tendon and bone (E-space), bulkiness of the reconstruction, and stability. As direct repair is rarely done, grafts are used to reinforce the pulley. An advantage of the first extensor retinaculum graft is the synovial coating providing the possibility to be used both as a direct graft with synovial coating or as an onlay graft after removal of the synovia when the native synovial layer is present. Methods: A graft from the first dorsal extensor compartment is used as an onlay graft to reinforce the sutured A4 pulley. This technique allows reconstruction of the original dimensions of the pulley system while stability is ensured by anchoring the onlay graft to the bony insertions of the pulley. Results: Anatomical reconstruction can be achieved with this method. The measured E-space remained 0 mm throughout the recovery, while the graft incorporated as a slim reinforcement of the pulley, displaying no bulkiness. Conclusions: The ideal reconstruction should provide synovial coating and sufficient strength with minimal bulk. Early reconstruction using an onlay graft offers these options. The native synovial lining is preserved and the graft is used to reinforce the pulley.}, language = {en} } @article{JordanBittrichFehskeetal.2017, author = {Jordan, Martin C. and Bittrich, Leonie A. and Fehske, Kai and Meffert, Rainer H. and Jansen, Hendrik}, title = {A rare case of Hoffa fracture combined with lateral patellar dislocation}, series = {Trauma Case Reports}, volume = {9}, journal = {Trauma Case Reports}, doi = {10.1016/j.tcr.2017.05.001}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158315}, pages = {13-16}, year = {2017}, abstract = {The coronal unicondylar fracture of the distal femur (AO 33-B3) is a rare intraarticular injury within the weight bearing area of the knee, initially described by Albert Hoffa in 1904. We report an unusual combination of a Hoffa fracture with lateral patellar dislocation in a young adult. Our patient sustained the injury by a sudden twist of his leg during sports. He presented clinically with knee swelling, dislocation of the patella, and localized tenderness; unable to bare weight. After plane radiograph confirmed the injury, manual reduction of the patella was done by hyperextension of the knee and medialward pressure. Afterwards, a CT scan and MRI were conducted. The injury was surgically treated with lag-screws, locking-plate and MPFL-reconstruction.}, language = {en} }