@article{FreyGassenmaierHofmannetal.2020, author = {Frey, Anna and Gassenmaier, Tobias and Hofmann, Ulrich and Schmitt, Dominik and Fette, Georg and Marx, Almuth and Heterich, Sabine and Boivin-Jahns, Val{\´e}rie and Ertl, Georg and Bley, Thorsten and Frantz, Stefan and Jahns, Roland and St{\"o}rk, Stefan}, title = {Coagulation factor XIII activity predicts left ventricular remodelling after acute myocardial infarction}, series = {ESC Heart Failure}, volume = {7}, journal = {ESC Heart Failure}, number = {5}, doi = {10.1002/ehf2.12774}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-236013}, pages = {2354-2364}, year = {2020}, abstract = {Aims Acute myocardial infarction (MI) is the major cause of chronic heart failure. The activity of blood coagulation factor XIII (FXIIIa) plays an important role in rodents as a healing factor after MI, whereas its role in healing and remodelling processes in humans remains unclear. We prospectively evaluated the relevance of FXIIIa after acute MI as a potential early prognostic marker for adequate healing. Methods and results This monocentric prospective cohort study investigated cardiac remodelling in patients with ST-elevation MI and followed them up for 1 year. Serum FXIIIa was serially assessed during the first 9 days after MI and after 2, 6, and 12 months. Cardiac magnetic resonance imaging was performed within 4 days after MI (Scan 1), after 7 to 9 days (Scan 2), and after 12 months (Scan 3). The FXIII valine-to-leucine (V34L) single-nucleotide polymorphism rs5985 was genotyped. One hundred forty-six patients were investigated (mean age 58 ± 11 years, 13\% women). Median FXIIIa was 118 \% (quartiles, 102-132\%) and dropped to a trough on the second day after MI: 109\%(98-109\%; P < 0.001). FXIIIa recovered slowly over time, reaching the baseline level after 2 to 6 months and surpassed baseline levels only after 12 months: 124 \% (110-142\%). The development of FXIIIa after MI was independent of the genotype. FXIIIa on Day 2 was strongly and inversely associated with the relative size of MI in Scan 1 (Spearman's ρ = -0.31; P = 0.01) and Scan 3 (ρ = -0.39; P < 0.01) and positively associated with left ventricular ejection fraction: ρ = 0.32 (P < 0.01) and ρ = 0.24 (P = 0.04), respectively. Conclusions FXIII activity after MI is highly dynamic, exhibiting a significant decline in the early healing period, with reconstitution 6 months later. Depressed FXIIIa early after MI predicted a greater size of MI and lower left ventricular ejection fraction after 1 year. The clinical relevance of these findings awaits to be tested in a randomized trial.}, language = {en} } @article{BeyhoffLohrThieleetal.2020, author = {Beyhoff, Niklas and Lohr, David and Thiele, Arne and Foryst-Ludwig, Anna and Klopfleisch, Robert and Schreiber, Laura M. and Kintscher, Ulrich}, title = {Myocardial Infarction After High-Dose Catecholamine Application—A Case Report From an Experimental Imaging Study}, series = {Frontiers in Cardiovascular Medicine}, volume = {7}, journal = {Frontiers in Cardiovascular Medicine}, doi = {10.3389/fcvm.2020.580296}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-217959}, year = {2020}, abstract = {Although heart failure following myocardial infarction (MI) represents a major health burden, underlying microstructural and functional changes remain incompletely understood. Here, we report on a case of unexpected MI after treatment with the catecholamine isoproterenol in an experimental imaging study in mice using different state-of-the-art imaging modalities. The decline in cardiac function was documented by ultrahigh-frequency echocardiography and speckle-tracking analyses. Myocardial microstructure was studied ex vivo at a spatial resolution of 100 × 100 × 100 μm\(^{3}\) using diffusion tensor magnetic resonance imaging (DT-MRI) and histopathologic analyses. Two weeks after ISO treatment, the animal showed an apical aneurysm accompanied by reduced radial strain in corresponding segments and impaired global systolic function. DT-MRI revealed a loss of contractile fiber tracts together with a disarray of remaining fibers as corresponding microstructural correlates. This preclinical case report provides valuable insights into pathophysiology and morphologic-functional relations of heart failure following MI using emerging imaging technologies.}, language = {en} } @article{GabrielJirůHillmannKraftetal.2020, author = {Gabriel, Katharina M. A. and J{\´i}rů-Hillmann, Steffi and Kraft, Peter and Selig, Udo and R{\"u}cker, Victoria and M{\"u}hler, Johannes and D{\"o}tter, Klaus and Keidel, Matthias and Soda, Hassan and Rascher, Alexandra and Schneider, Rolf and Pfau, Mathias and Hoffmann, Roy and Stenzel, Joachim and Benghebrid, Mohamed and Goebel, Tobias and Doerck, Sebastian and Kramer, Daniela and Haeusler, Karl Georg and Volkmann, Jens and Heuschmann, Peter U. and Fluri, Felix}, title = {Two years' experience of implementing a comprehensive telemedical stroke network comprising in mainly rural region: the Transregional Network for Stroke Intervention with Telemedicine (TRANSIT-Stroke)}, series = {BMC Neurology}, volume = {20}, journal = {BMC Neurology}, doi = {10.1186/s12883-020-01676-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229214}, year = {2020}, abstract = {Background Telemedicine improves the quality of acute stroke care in rural regions with limited access to specialized stroke care. We report the first 2 years' experience of implementing a comprehensive telemedical stroke network comprising all levels of stroke care in a defined region. Methods The TRANSIT-Stroke network covers a mainly rural region in north-western Bavaria (Germany). All hospitals providing acute stroke care in this region participate in TRANSIT-Stroke, including four hospitals with a supra-regional certified stroke unit (SU) care (level III), three of those providing teleconsultation to two hospitals with a regional certified SU (level II) and five hospitals without specialized SU care (level I). For a two-year-period (01/2015 to 12/2016), data of eight of these hospitals were available; 13 evidence-based quality indicators (QIs) related to processes during hospitalisation were evaluated quarterly and compared according to predefined target values between level-I- and level-II/III-hospitals. Results Overall, 7881 patients were included (mean age 74.6 years +/- 12.8; 48.4\% female). In level-II/III-hospitals adherence of all QIs to predefined targets was high ab initio. In level-I-hospitals, three patterns of QI-development were observed: a) high adherence ab initio (31\%), mainly in secondary stroke prevention; b) improvement over time (44\%), predominantly related to stroke specific diagnosis and in-hospital organization; c) no clear time trends (25\%). Overall, 10 out of 13 QIs reached predefined target values of quality of care at the end of the observation period. Conclusion The implementation of the comprehensive TRANSIT-Stroke network resulted in an improvement of quality of care in level-I-hospitals.}, language = {en} } @article{MartensPanzervandenWijngaardetal.2020, author = {Martens, Johannes and Panzer, Sabine and van den Wijngaard, Jeroen and Siebes, Maria and Schreiber, Laura M.}, title = {Influence of contrast agent dispersion on bolus-based MRI myocardial perfusion measurements: A computational fluid dynamics study}, series = {Magnetic Resonance in Medicine}, volume = {84}, journal = {Magnetic Resonance in Medicine}, number = {1}, doi = {10.1002/mrm.28125}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-208698}, pages = {467-483}, year = {2020}, abstract = {Purpose: Bolus-based dynamic contrast agent (CA) perfusion measurements of the heart are subject to systematic errors due to CA bolus dispersion in the coronary arteries. To better understand these effects on quantification of myocardial blood flow and myocardial perfusion reserve (MPR), an in-silico model of the coronary arteries down to the pre-arteriolar vessels has been developed. Methods: In this work, a computational fluid dynamics analysis is performed to investigate these errors on the basis of realistic 3D models of the left and right porcine coronary artery trees, including vessels at the pre-arteriolar level. Using advanced boundary conditions, simulations of blood flow and CA transport are conducted at rest and under stress. These are evaluated with regard to dispersion (assessed by the width of CA concentration time curves and associated vascular transport functions) and errors of myocardial blood flow and myocardial perfusion reserve quantification. Results: Contrast agent dispersion increases with traveled distance as well as vessel diameter, and decreases with higher flow velocities. Overall, the average myocardial blood flow errors are -28\% ± 16\% and -8.5\% ± 3.3\% at rest and stress, respectively, and the average myocardial perfusion reserve error is 26\% ± 22\%. The calculated values are different in the left and right coronary tree. Conclusion: Contrast agent dispersion is dependent on a complex interplay of several different factors characterizing the cardiovascular bed, including vessel size and integrated vascular length. Quantification errors evoked by the observed CA dispersion show nonnegligible distortion in dynamic CA bolus-based perfusion measurements. We expect future improvements of quantitative perfusion measurements to make the systematic errors described here more apparent.}, language = {en} } @phdthesis{Pickel2020, author = {Pickel, Simone}, title = {Role of the β subunit of L-type calcium channels in cardiac hypertrophy}, doi = {10.25972/OPUS-19282}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-192829}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2020}, abstract = {L-type calcium channels (LTCCs) control crucial physiological processes in cardiomyocytes such as the duration and amplitude of action potentials, excitation-contraction coupling and gene expression, by regulating the entry of Ca2+ into the cells. Cardiac LTCCs consist of one pore-forming α1 subunit and the accessory subunits Cavβ, Cavα2δ and Cavγ. Of these auxiliary subunits, Cavβ is the most important regulator of the channel activity; however, it can also have LTCC-independent cellular regulatory functions. Therefore, changes in the expression of Cavβ can lead not only to a dysregulation of LTCC activity, but also to changes in other cellular functions. Cardiac hypertrophy is one of the most relevant risk factors for congestive heart failure and depends on the activation of calcium-dependent prohypertrophic signaling pathways. However, the role of LTCCs and especially Cavβ in this pathology is controversial and needs to be further elucidated. Of the four Cavβ isoforms, Cavβ2 is the predominant one in cardiomyocytes. Moreover, there are five different splice variants of Cavβ2 (Cavβ2a-e), differing only in the N-terminal region. We reported that Cavβ2b is the predominant variant expressed in the heart. We also revealed that a pool of Cavβ2 is targeted to the nucleus in cardiomyocytes. The expression of the nuclear Cavβ2 decreases during in vitro and in vivo induction of cardiomyocyte hypertrophy and overexpression of a nucleus-targeted Cavβ2 completely abolishes the in vitro induced hypertrophy. Additionally, we demonstrated by shRNA-mediated protein knockdown that downregulation of Cavβ2 enhances the hypertrophy induced by the α1-adrenergic agonist phenylephrine (PE) without involvement of LTCC activity. These results suggest that Cavβ2 can regulate cardiac hypertrophy through LTCC-independent pathways. To further validate the role of the nuclear Cavβ2, we performed quantitative proteome analyses of Cavβ2-deficient neonatal rat cardiomyocytes (NRCs). The results show that downregulation of Cavβ2 influences the expression of various proteins, including a decrease of calpastatin, an inhibitor of the calcium-dependent cysteine protease calpain. Moreover, downregulation of Cavβ2 during cardiomyocyte hypertrophy drastically increases calpain activity as compared to controls after treatment with PE. Finally, the inhibition of calpain by calpeptin abolishes the increase in PE-induced hypertrophy in Cavβ2-deficient cells. These results suggest that nuclear Cavβ2 has Ca2+- and LTCC-independent functions during the development of hypertrophy. Overall, our results indicate a new role for Cavβ2 in antihypertrophic signaling in cardiac hypertrophy.}, subject = {Herzhypertrophie}, language = {en} } @article{ElabyadTerekhovLohretal.2020, author = {Elabyad, Ibrahim A. and Terekhov, Maxim and Lohr, David and Stefanescu, Maria R. and Baltes, Steffen and Schreiber, Laura M.}, title = {A Novel Mono-surface Antisymmetric 8Tx/16Rx Coil Array for Parallel Transmit Cardiac MRI in Pigs at 7T}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, number = {1}, doi = {10.1038/s41598-020-59949-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229436}, year = {2020}, abstract = {A novel mono-surface antisymmetric 16-element transmit/receive (Tx/Rx) coil array was designed, simulated, constructed, and tested for cardiac magnetic resonance imaging (cMRI) in pigs at 7T. The cardiac array comprised of a mono-surface 16-loops with two central elements arranged antisymmetrically and flanked by seven elements on either side. The array was configured for parallel transmit (pTx) mode to have an eight channel transmit and 16-channel receive (8Tx/16Rx) coil array. Electromagnetic (EM) simulations, bench-top measurements, phantom, and MRI experiments with two pig cadavers (68 and 46 kg) were performed. Finally, the coil was used in pilot in-vivo measurements with a 60 kg pig. Flip angle (FA), geometry factor (g-factor), signal-to-noise ratio (SNR) maps, and high-resolution cardiac images were acquired with an in-plane resolution of 0.6 mm x 0.6 mm (in-vivo) and 0.3 mm x 0.3 mm (ex-vivo). The mean g-factor over the heart was 1.26 (R = 6). Static phase B-1(+) shimming in a pig body phantom with the optimal phase vectors makes possible to improve the B-1(+) homogeneity by factor > 2 and transmit efficiency by factor > 3 compared to zero phases (before RF shimming). Parallel imaging performed in the in-vivo measurements demonstrated well preserved diagnostic quality of the resulting images at acceleration factors up to R = 6. The described hardware design can be adapted for arrays optimized for animals and humans with a larger number of elements (32-64) while maintaining good decoupling for various MRI applications at UHF (e.g., cardiac, head, and spine).}, language = {en} } @article{KolokotronisPlutaKlopockietal.2020, author = {Kolokotronis, Konstantinos and Pluta, Natalie and Klopocki, Eva and Kunstmann, Erdmute and Messroghli, Daniel and Maack, Christoph and Tejman-Yarden, Shai and Arad, Michael and Rost, Simone and Gerull, Brenda}, title = {New Insights on Genetic Diagnostics in Cardiomyopathy and Arrhythmia Patients Gained by Stepwise Exome Data Analysis}, series = {Journal of Clinical Medicine}, volume = {9}, journal = {Journal of Clinical Medicine}, number = {7}, doi = {10.3390/jcm9072168}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-236094}, year = {2020}, abstract = {Inherited cardiomyopathies are characterized by clinical and genetic heterogeneity that challenge genetic diagnostics. In this study, we examined the diagnostic benefit of exome data compared to targeted gene panel analyses, and we propose new candidate genes. We performed exome sequencing in a cohort of 61 consecutive patients with a diagnosis of cardiomyopathy or primary arrhythmia, and we analyzed the data following a stepwise approach. Overall, in 64\% of patients, a variant of interest (VOI) was detected. The detection rate in the main sub-cohort consisting of patients with dilated cardiomyopathy (DCM) was much higher than previously reported (25/36; 69\%). The majority of VOIs were found in disease-specific panels, while a further analysis of an extended panel and exome data led to an additional diagnostic yield of 13\% and 5\%, respectively. Exome data analysis also detected variants in candidate genes whose functional profile suggested a probable pathogenetic role, the strongest candidate being a truncating variant in STK38. In conclusion, although the diagnostic yield of gene panels is acceptable for routine diagnostics, the genetic heterogeneity of cardiomyopathies and the presence of still-unknown causes favor exome sequencing, which enables the detection of interesting phenotype-genotype correlations, as well as the identification of novel candidate genes.}, language = {en} } @article{HoffmannJanssenKannoetal.2020, author = {Hoffmann, Jan V. and Janssen, Jan P. and Kanno, Takayuki and Shibutani, Takayuki and Onoguchi, Masahisa and Lapa, Constantin and Grunz, Jan-Peter and Buck, Andreas K. and Higuchi, Takahiro}, title = {Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging}, series = {EJNMMI Physics}, volume = {7}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-020-00335-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230361}, year = {2020}, abstract = {Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT\(^+\)). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with \(^{99m}\)Tc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT\(^+\) for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT\(^+\). In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7\% (XUHR-M), 29.1\% (GP-M, U-SPECT5-E), 16.3\% (GP-M, U-SPECT\(^+\)) and 23.0\% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.}, language = {en} } @article{GrebeMalzahnDonhauseretal.2020, author = {Grebe, S{\"o}ren Jendrik and Malzahn, Uwe and Donhauser, Julian and Liu, Dan and Wanner, Christoph and Krane, Vera and Hammer, Fabian}, title = {Quantification of left ventricular mass by echocardiography compared to cardiac magnet resonance imaging in hemodialysis patients}, series = {Cardiovascular Ultrasound}, volume = {18}, journal = {Cardiovascular Ultrasound}, doi = {10.1186/s12947-020-00217-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229282}, year = {2020}, abstract = {Background: Left ventricular hypertrophy (LVH), defined by the left ventricular mass index (LVMI), is highly prevalent in hemodialysis patients and a strong independent predictor of cardiovascular events. Compared to cardiac magnetic resonance imaging (CMR), echocardiography tends to overestimate the LVMI. Here, we evaluate the diagnostic performance of transthoracic echocardiography (TTE) compared to CMR regarding the assessment of LVMI in hemodialysis patients. Methods: TTR and CMR data for 95 hemodialysis patients who participated in the MiREnDa trial were analyzed. The LVMI was calculated by two-dimensional (2D) TTE-guided M-mode measurements employing the American Society of Echocardiography (ASE) and Teichholz (Th) formulas, which were compared to the reference method, CMR. Results: LVH was present in 44\% of patients based on LVMI measured by CMR. LVMI measured by echocardiography correlated moderately with CMR, ASE: r = 0.44 (0.34-0.62); Th: r = 0.44 (0.32-0.62). Compared to CMR, both echocardiographic formulas overestimated LVMI (mean increment LVMI (ASE-CMR): 19.5 +/- 19.48 g/m(2),p < 0.001; mean increment LVMI (Th-CMR): 15.9 +/- 15.89 g/m(2),p < 0.001). We found greater LVMI overestimation in patients with LVH using the ASE formula compared to the Th formula. Stratification of patients into CMR LVMI quartiles showed a continuous decrease in increment LVMI with increasing CMR LVMI quartiles for the Th formula (p < 0.001) but not for the ASE formula (p = 0.772). Bland-Altman analysis showed that the Th formula had a constant bias independent of LVMI. Both methods had good discrimination ability for the detection of LVH (ROC-AUC: 0.819 (0.737-0.901) and 0.808 (0.723-0.892) for Th and ASE, respectively). Conclusions: The ASE and Th formulas overestimate LVMI in hemodialysis patients. However, the overestimation is less with the Th formula, particularly with increasing LVMI. The results suggest that the Th formula should be preferred for measurement of LVMI in chronic hemodialysis patients.}, language = {en} } @article{JanssenHoffmannKannoetal.2020, author = {Janssen, Jan P. and Hoffmann, Jan V. and Kanno, Takayuki and Nose, Naoko and Grunz, Jan-Peter and Onoguchi, Masahisa and Chen, Xinyu and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro}, title = {Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, doi = {10.1038/s41598-020-75696-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230616}, year = {2020}, abstract = {We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5\%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.}, language = {en} }