@article{MirallesVargiuDauwalderetal.2015, author = {Miralles, Felip and Vargiu, Eloisa and Dauwalder, Stefan and Sol{\`a}, Marc and M{\"u}ller-Putz, Gernot and Wriessnegger, Selina C. and Pinegger, Andreas and K{\"u}bler, Andrea and Halder, Sebastian and K{\"a}thner, Ivo and Martin, Suzanne and Daly, Jean and Armstrong, Elaine and Guger, Christoph and Hinterm{\"u}ller, Christoph and Lowish, Hannah}, title = {Brain computer interface on track to home.}, series = {The Scientific World Journal}, volume = {2015}, journal = {The Scientific World Journal}, number = {623896}, doi = {10.1155/2015/623896}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-149575}, year = {2015}, abstract = {The novel BackHome system offers individuals with disabilities a range of useful services available via brain-computer interfaces (BCIs), to help restore their independence. This is the time such technology is ready to be deployed in the real world, that is, at the target end users' home. This has been achieved by the development of practical electrodes, easy to use software, and delivering telemonitoring and home support capabilities which have been conceived, implemented, and tested within a user-centred design approach. The final BackHome system is the result of a 3-year long process involving extensive user engagement to maximize effectiveness, reliability, robustness, and ease of use of a home based BCI system. The system is comprised of ergonomic and hassle-free BCI equipment; one-click software services for Smart Home control, cognitive stimulation, and web browsing; and remote telemonitoring and home support tools to enable independent home use for nonexpert caregivers and users. BackHome aims to successfully bring BCIs to the home of people with limited mobility to restore their independence and ultimately improve their quality of life.}, language = {en} } @article{SimonKaethnerRufetal.2015, author = {Simon, Nadine and K{\"a}thner, Ivo and Ruf, Carolin A. and Pasqualotto, Emanuele and K{\"u}bler, Andrea and Halder, Sebastian}, title = {An auditory multiclass brain-computer interface with natural stimuli: Usability evaluation with healthy participants and a motor impaired end user}, series = {Frontiers in Human Neuroscience}, volume = {8}, journal = {Frontiers in Human Neuroscience}, number = {1039}, doi = {10.3389/fnhum.2014.01039}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126450}, year = {2015}, abstract = {Brain-computer interfaces (BCIs) can serve as muscle independent communication aids. Persons, who are unable to control their eye muscles (e.g., in the completely locked-in state) or have severe visual impairments for other reasons, need BCI systems that do not rely on the visual modality. For this reason, BCIs that employ auditory stimuli were suggested. In this study, a multiclass BCI spelling system was implemented that uses animal voices with directional cues to code rows and columns of a letter matrix. To reveal possible training effects with the system, 11 healthy participants performed spelling tasks on 2 consecutive days. In a second step, the system was tested by a participant with amyotrophic lateral sclerosis (ALS) in two sessions. In the first session, healthy participants spelled with an average accuracy of 76\% (3.29 bits/min) that increased to 90\% (4.23 bits/min) on the second day. Spelling accuracy by the participant with ALS was 20\% in the first and 47\% in the second session. The results indicate a strong training effect for both the healthy participants and the participant with ALS. While healthy participants reached high accuracies in the first session and second session, accuracies for the participant with ALS were not sufficient for satisfactory communication in both sessions. More training sessions might be needed to improve spelling accuracies. The study demonstrated the feasibility of the auditory BCI with healthy users and stresses the importance of training with auditory multiclass BCIs, especially for potential end-users of BCI with disease.}, language = {en} } @article{KaethnerKueblerHalder2015, author = {K{\"a}thner, Ivo and K{\"u}bler, Andrea and Halder, Sebastian}, title = {Rapid P300 brain-computer interface communication with a head-mounted display}, series = {Frontiers in Neuroscience}, volume = {9}, journal = {Frontiers in Neuroscience}, number = {207}, doi = {10.3389/fnins.2015.00207}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-148520}, year = {2015}, abstract = {Visual ERP (P300) based brain-computer interfaces (BCIs) allow for fast and reliable spelling and are intended as a muscle-independent communication channel for people with severe paralysis. However, they require the presentation of visual stimuli in the field of view of the user. A head-mounted display could allow convenient presentation of visual stimuli in situations, where mounting a conventional monitor might be difficult or not feasible (e.g., at a patient's bedside). To explore if similar accuracies can be achieved with a virtual reality (VR) headset compared to a conventional flat screen monitor, we conducted an experiment with 18 healthy participants. We also evaluated it with a person in the locked-in state (LIS) to verify that usage of the headset is possible for a severely paralyzed person. Healthy participants performed online spelling with three different display methods. In one condition a 5 x 5 letter matrix was presented on a conventional 22 inch TFT monitor. Two configurations of the VR headset were tested. In the first (glasses A), the same 5 x 5 matrix filled the field of view of the user. In the second (glasses B), single letters of the matrix filled the field of view of the user. The participant in the LIS tested the VR headset on three different occasions (glasses A condition only). For healthy participants, average online spelling accuracies were 94\% (15.5 bits/min) using three flash sequences for spelling with the monitor and glasses A and 96\% (16.2 bits/min) with glasses B. In one session, the participant in the LIS reached an online spelling accuracy of 100\% (10 bits/min) using the glasses A condition. We also demonstrated that spelling with one flash sequence is possible with the VR headset for healthy users (mean: 32.1 bits/min, maximum reached by one user: 71.89 bits/min at 100\% accuracy). We conclude that the VR headset allows for rapid P300 BCI communication in healthy users and may be a suitable display option for severely paralyzed persons.}, language = {en} } @article{KueblerHolzRiccioetal.2014, author = {K{\"u}bler, Andrea and Holz, Elisa M. and Riccio, Angela and Zickler, Claudia and Kaufmann, Tobias and Kleih, Sonja C. and Staiger-S{\"a}lzer, Pit and Desideri, Lorenzo and Hoogerwerf, Evert-Jan and Mattia, Donatella}, title = {The User-Centered Design as Novel Perspective for Evaluating the Usability of BCI-Controlled Applications}, doi = {10.1371/journal.pone.0112392}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-111051}, year = {2014}, abstract = {Albeit research on brain-computer interfaces (BCI) for controlling applications has expanded tremendously, we still face a translational gap when bringing BCI to end-users. To bridge this gap, we adapted the user-centered design (UCD) to BCI research and development which implies a shift from focusing on single aspects, such as accuracy and information transfer rate (ITR), to a more holistic user experience. The UCD implements an iterative process between end-users and developers based on a valid evaluation procedure. Within the UCD framework usability of a device can be defined with regard to its effectiveness, efficiency, and satisfaction. We operationalized these aspects to evaluate BCI-controlled applications. Effectiveness was regarded equivalent to accuracy of selections and efficiency to the amount of information transferred per time unit and the effort invested (workload). Satisfaction was assessed with questionnaires and visual-analogue scales. These metrics have been successfully applied to several BCI-controlled applications for communication and entertainment, which were evaluated by end-users with severe motor impairment. Results of four studies, involving a total of N = 19 end-users revealed: effectiveness was moderate to high; efficiency in terms of ITR was low to high and workload low to medium; depending on the match between user and technology, and type of application satisfaction was moderate to high. The here suggested evaluation metrics within the framework of the UCD proved to be an applicable and informative approach to evaluate BCI controlled applications, and end-users with severe impairment and in the locked-in state were able to participate in this process.}, language = {en} } @article{HalderHammerKleihetal.2013, author = {Halder, Sebastian and Hammer, Eva Maria and Kleih, Sonja Claudia and Bogdan, Martin and Rosenstiel, Wolfgang and Birbaumer, Niels and K{\"u}bler, Andrea}, title = {Prediction of Auditory and Visual P300 Brain-Computer Interface Aptitude}, series = {PLoS ONE}, volume = {8}, journal = {PLoS ONE}, number = {2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-130327}, pages = {e53513}, year = {2013}, abstract = {Objective Brain-computer interfaces (BCIs) provide a non-muscular communication channel for patients with late-stage motoneuron disease (e.g., amyotrophic lateral sclerosis (ALS)) or otherwise motor impaired people and are also used for motor rehabilitation in chronic stroke. Differences in the ability to use a BCI vary from person to person and from session to session. A reliable predictor of aptitude would allow for the selection of suitable BCI paradigms. For this reason, we investigated whether P300 BCI aptitude could be predicted from a short experiment with a standard auditory oddball. Methods Forty healthy participants performed an electroencephalography (EEG) based visual and auditory P300-BCI spelling task in a single session. In addition, prior to each session an auditory oddball was presented. Features extracted from the auditory oddball were analyzed with respect to predictive power for BCI aptitude. Results Correlation between auditory oddball response and P300 BCI accuracy revealed a strong relationship between accuracy and N2 amplitude and the amplitude of a late ERP component between 400 and 600 ms. Interestingly, the P3 amplitude of the auditory oddball response was not correlated with accuracy. Conclusions Event-related potentials recorded during a standard auditory oddball session moderately predict aptitude in an audiory and highly in a visual P300 BCI. The predictor will allow for faster paradigm selection. Significance Our method will reduce strain on patients because unsuccessful training may be avoided, provided the results can be generalized to the patient population.}, language = {en} } @article{HalderVarkutiBogdanetal.2013, author = {Halder, Sebastian and Varkuti, Balint and Bogdan, Martin and K{\"u}bler, Andrea and Rosenstiel, Wolfgang and Sitaram, Ranganatha and Birbaumer, Niels}, title = {Prediction of brain-computer interface aptitude from individual brain structure}, series = {Frontiers in Human Neuroscience}, journal = {Frontiers in Human Neuroscience}, doi = {10.3389/fnhum.2013.00105}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-96558}, year = {2013}, abstract = {Objective: Brain-computer interface (BCI) provide a non-muscular communication channel for patients with impairments of the motor system. A significant number of BCI users is unable to obtain voluntary control of a BCI-system in proper time. This makes methods that can be used to determine the aptitude of a user necessary. Methods: We hypothesized that integrity and connectivity of involved white matter connections may serve as a predictor of individual BCI-performance. Therefore, we analyzed structural data from anatomical scans and DTI of motor imagery BCI-users differentiated into high and low BCI-aptitude groups based on their overall performance. Results: Using a machine learning classification method we identified discriminating structural brain trait features and correlated the best features with a continuous measure of individual BCI-performance. Prediction of the aptitude group of each participant was possible with near perfect accuracy (one error). Conclusions: Tissue volumetric analysis yielded only poor classification results. In contrast, the structural integrity and myelination quality of deep white matter structures such as the Corpus Callosum, Cingulum, and Superior Fronto-Occipital Fascicle were positively correlated with individual BCI-performance. Significance: This confirms that structural brain traits contribute to individual performance in BCI use.}, language = {en} } @article{HalderHammerKleihetal.2013, author = {Halder, Sebastian and Hammer, Eva Maria and Kleih, Sonja Claudia and Bogdan, Martin and Rosenstiel, Wolfgang and Birbaumer, Nils and K{\"u}bler, Andrea}, title = {Prediction of Auditory and Visual P300 Brain-Computer Interface Aptitude}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-77992}, year = {2013}, abstract = {Objective: Brain-computer interfaces (BCIs) provide a non-muscular communication channel for patients with late-stage motoneuron disease (e.g., amyotrophic lateral sclerosis (ALS)) or otherwise motor impaired people and are also used for motor rehabilitation in chronic stroke. Differences in the ability to use a BCI vary from person to person and from session to session. A reliable predictor of aptitude would allow for the selection of suitable BCI paradigms. For this reason, we investigated whether P300 BCI aptitude could be predicted from a short experiment with a standard auditory oddball. Methods: Forty healthy participants performed an electroencephalography (EEG) based visual and auditory P300-BCI spelling task in a single session. In addition, prior to each session an auditory oddball was presented. Features extracted from the auditory oddball were analyzed with respect to predictive power for BCI aptitude. Results: Correlation between auditory oddball response and P300 BCI accuracy revealed a strong relationship between accuracy and N2 amplitude and the amplitude of a late ERP component between 400 and 600 ms. Interestingly, the P3 amplitude of the auditory oddball response was not correlated with accuracy. Conclusions: Event-related potentials recorded during a standard auditory oddball session moderately predict aptitude in an audiory and highly in a visual P300 BCI. The predictor will allow for faster paradigm selection. Significance: Our method will reduce strain on patients because unsuccessful training may be avoided, provided the results can be generalized to the patient population.}, subject = {Psychologie}, language = {en} }