TY - JOUR A1 - Vogt, Marius L. A1 - Kollikowski, Alexander M. A1 - Weidner, Franziska A1 - Strinitz, Marc A1 - Feick, Jörn A1 - Essig, Fabian A1 - Neugebauer, Herrmann A1 - Haeusler, Karl Georg A1 - Pham, Mirko A1 - Maerz, Alexander T1 - Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke JF - Clinical Neuroradiology N2 - Background It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. Methods Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019–09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result. Results A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7%) treated with AP vs. 150 patients (50.3%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7% for AP vs. 79.3% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7% for AP and 16.0% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups. Conclusion In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness. KW - APERIO Hybrid KW - mechanical thrombectomy KW - stent-retriever device KW - stroke KW - APERIO Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-264817 VL - 32 IS - 1 ER - TY - JOUR A1 - Strinitz, Marc A1 - Pham, Mirko A1 - März, Alexander G. A1 - Feick, Jörn A1 - Weidner, Franziska A1 - Vogt, Marius L. A1 - Essig, Fabian A1 - Neugebauer, Hermann A1 - Stoll, Guido A1 - Schuhmann, Michael K. A1 - Kollikowski, Alexander M. T1 - Immune cells invade the collateral circulation during human stroke: prospective replication and extension JF - International Journal of Molecular Sciences N2 - It remains unclear if principal components of the local cerebral stroke immune response can be reliably and reproducibly observed in patients with acute large-vessel-occlusion (LVO) stroke. We prospectively studied a large independent cohort of n = 318 consecutive LVO stroke patients undergoing mechanical thrombectomy during which cerebral blood samples from within the occluded anterior circulation and systemic control samples from the ipsilateral cervical internal carotid artery were obtained. An extensive protocol was applied to homogenize the patient cohort and to standardize the procedural steps of endovascular sample collection, sample processing, and laboratory analyses. N = 58 patients met all inclusion criteria. (1) Mean total leukocyte counts were significantly higher within the occluded ischemic cerebral vasculature (I) vs. intraindividual systemic controls (S): +9.6%, I: 8114/µL ± 529 vs. S: 7406/µL ± 468, p = 0.0125. (2) This increase was driven by neutrophils: +12.1%, I: 7197/µL ± 510 vs. S: 6420/µL ± 438, p = 0.0022. Leukocyte influx was associated with (3) reduced retrograde collateral flow (R\(^2\) = 0.09696, p = 0.0373) and (4) greater infarct extent (R\(^2\) = 0.08382, p = 0.032). Despite LVO, leukocytes invade the occluded territory via retrograde collateral pathways early during ischemia, likely compromising cerebral hemodynamics and tissue integrity. This inflammatory response can be reliably observed in human stroke by harvesting immune cells from the occluded cerebral vascular compartment. KW - ischemic stroke KW - cerebral ischemia KW - mechanical thrombectomy KW - large vessel occlusion KW - leukocytes KW - neutrophils KW - collateral circulation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-284281 SN - 1422-0067 VL - 22 IS - 17 ER -