TY - THES A1 - Mandel, Philipp T1 - Entstehung von oxidativen Stressmarkern in DNA und RNA nach der Behandlung mit den Hormonen Angiotensin II und Aldosteron in vitro und in vivo : Vergleich von drei Analysemethoden zum Nachweis von 8-Oxo-2'-desoxyguanosin in LLC-PK1-Zellen T1 - Formation of oxidative stress markers in DNA and RNA after treatment with aldosterone and angiotensin II in vitro and in vivo N2 - The detection of oxidative stress markers has gained increasing importancy in the early investigation of diseases like diabetes, cancer or hypertension. 8 oxo 2' deoxyguanosine (8-oxodG) is the main marker, which is used for the intracellular detection of oxidative stress levels. However, the oxidative stress markers 8 oxoguanine (8-oxoGua), a product of the DNA base excision repair and 8 oxoguanosine (8-oxoGuo), a marker for oxidative damaged RNA have received less attention up to now. The renin-angiotensin-aldosterone system (RAAS) plays an important role in the regulation processes of the blood pressure system. During hypertension angiotensin II (Ang II) and aldosterone (Aldo) are released in high concentrations over a longer period leading to non-physiological effects of the RAAS hormones. Subsequently, an increase of the intracellular oxidative stress level in kidney cells can be measured. The aim of this thesis is the in vitro and in vivo detection of the oxidative damage in DNA and RNA by measuring oxidative stress markers, especially 8-oxodG which is triggered by Ang II and Aldo. In vitro experiments were carried out in LLC-PK1, a cell line originated from porcine kidney cells. It could been shown that Ang II and Aldo led to a dose-dependent increase of DNA damage in the cells. A time-dependent increase was detected for the first 30 minutes of the treatment. For the rest of the experimental set up (4 h) the level of detected DNA damage remained constant. The FPG comet assay and the immunocytochemical staining showed a significant increase of 8-oxodG in the cells, whereas the HPLC-MS/MS measurement only detected a small increase of 8-oxodG in the DNA. The FPG enzyme, which recognises also other oxidized purines besides 8-oxodG, which led to an overestimation of 8-oxodG in the comet assay. Also, the 8 oxodG antibody, which was used in the immunocytochemical analysis, detected higher amounts of 8-oxodG most likely due to its side reactions with other oxidized DNA structures. One of the main advantages of the last mentioned methods is the direct measurement in damaged cells, whereas the HPLC-MS/MS requires an isolation of the DNA. During this isolation process the oxidative stress markers can be oxidized and the detection can become imprecise. The main purpose of the in vivo experiments was the detection of the oxidative stress marker 8-oxoGua, 8-oxodG and 8-oxoGuo in the urine of test animals. The treatment of C57BL/6 mice and Sprague Dawley (SD) rats with the RAAS hormones led to an increase of the blood pressure, higher DNA damage due to oxidative stress as well as an increased excretion rate of oxidative stress markers. The inhibition of the angiotensin II type 1- or mineralocorticoid receptor and a mutation of the AT1a gene could show, that the DNA damage is independent from the hypertension. In addition, it was shown that the NOX4 is not alone responsible for the oxidative stress. Other NADPH oxidases must contribute to the induction of oxidative stress inside the cell. Moreover, the activation of the Nrf2 pathway has an influence on the effect of Aldo in SD rats. The excretion rate of the oxidative stress markers in the 20 h urine of the treated animals showed how the equilibrium between the DNA repair and the oxidative stress level was changing over time. The measurement of 8-oxoGuo became more and more popular, because up to the fact that 80 % of the DNA is translated into RNA. Overall, the detection of 8-oxodG and 8-oxoGuo is feasible for monitoring the disease or the healing process, because the measurement is non-invasive. The detection of 8-oxodG and 8-oxoGuo in nucleic acids is a first step into the field of basic research methods, because it reveals a snapshot of the nucleic acid damage in the cell at a specific time point. Usually, there will be an overestimation of the oxidative stress marker resulting from the analytical method. Although, it is possible to detect an underestimation of oxidative stress markers in tissue samples if not all cell types are damaged equally. Therefore, a primary goal should be the detection of a stable oxidation product of guanine to insure a reliable detection strategy and for a better understanding of the equilibrium of DNA oxidation and repair. N2 - Der Nachweis von oxidativen Stressmarkern hat bei der Untersuchung von Krankheiten wie Diabetes, Krebs und Hypertonie an großer Bedeutung gewonnen. Vor allem 8-Oxo-2’-desoxyguanosin (8-oxodG) wird gezielt mit verschiedenen Methoden gemessen und als Marker für oxidativen Stress herangezogen. Daneben haben 8 Oxoguanin (8-oxoGua), als Produkt aus der Basenexzisionsreparatur der DNA, sowie 8-Oxoguanosin (8-oxoGuo), als Biomarker für oxidativ geschädigte RNA, bisher weniger Aufmerksamkeit bekommen. Das Renin-Angiotensin Aldosteron System (RAAS) spielt eine wichtige Rolle in der Regulierung des Blutdrucks. Im Falle einer Hypertonie werden Angiotensin II (Ang II) und Aldosteron (Aldo) über einen langen Zeitraum in erhöhter Konzentration ausgeschüttet. Dieser Umstand bewirkt eine nicht physiologische Wirkung der Hormone des RAAS, welche zu einer Induktion von oxidativem Stress führt. Die Zielsetzung dieser Arbeit ist es, die oxidative Schädigung, ausgelöst durch Ang II und Aldo, in der DNA und der RNA in vitro und in vivo nachzuweisen und dabei speziell den Biomarker 8-oxodG zu untersuchen. In-vitro-Experimente wurden mit LLC PK1-Zellen, einer Schweinenierenzelllinie, durchgeführt. Ang II und Aldo lösten einen dosisabhängigen Anstieg der DNA Schäden in LLC PK1 Zellen aus. Eine Zeitabhängigkeit wurde für die ersten 30 Minuten gezeigt. Für die restliche Zeit (4 h) blieb der nachgewiesene DNA Schaden konstant. Der FPG Comet-Assay und die immunzytochemische Färbung zeigten jeweils eine signifikante Zunahme von 8-oxodG in LLC-PK1-Zellen an, während die HPLC MS/MS Messung nur geringe Veränderungen nachwies. Das FPG Enzym erkennt neben 8-oxodG auch andere oxidierte Purine und sorgte so für eine Überbestimmung des DNA-Schadens. Bei der immunzytochemischen Färbung entsteht die Überbestimmung durch Kreuzreaktionen des 8 oxodG Antikörpers mit oxidierten Strukturen in der DNA. Der Vorteil beider Analysemethoden ist die direkte Messung von Schädigungen in der Zelle, während die HPLC-MS/MS eine Isolierung der Nukleinsäuren voraussetzt. Bei diesem Schritt kann es zur Oxidation der Marker für oxidativen Stress kommen, welche einen genauen Nachweis erschwert. In vivo-Versuche hatten zum Ziel, die oxidativen Stressmarker 8-oxoGua, 8-oxodG und 8-oxoGuo im Urin nachzuweisen. Die Behandlung der C57BL/6-Mäuse und Sprague Dawley-Ratten (SD-Ratten) mit den Hormonen des RAAS zeigten einen Anstieg des Blutdrucks, erhöhte DNA Schäden durch oxidativen Stress sowie erhöhte Exkretionsraten der oxidativen Stressmarker. Durch eine Inhibierung des Angiotensin II-Typ1- oder Mineralkortikoidrezeptors sowie die Mutation des Gens AT1a konnte gezeigt werden, dass die Schädigungen unabhängig vom Blutdruck sind. Zudem konnte gezeigt werden, dass neben NOX4 auch andere NADPH Oxidasen für den oxidativen Stress verantwortlich sein müssen. Eine Aktivierung des Nrf2 Signalweges in den SD-Ratten hat Einfluss auf die Wirkung von Aldo. Die Exkretionsrate der oxidativen Biomarker im 20-h-Urin der behandelten Tiere zeigen, wie sich das Gleichgewicht zwischen DNA-Reparatur und oxidativem Stress verändert. Da 80 % der DNA in RNA umgeschrieben werden, ist der Nachweis von 8 oxoGuo in den Fokus gerückt. In der praktischen Anwendung kann mit der Messung von 8 oxodG und 8-oxoGuo ein Krankheits- oder Heilungsprozess auf nicht invasive Weise verfolgt werden. Der Nachweis von 8-oxodG und 8-oxoGuo in den Nukleinsäuren stellt einen Einstieg für die Grundlagenforschung dar, da sie nur eine Momentaufnahme der Nukleinsäureschädigung in der Zelle zeigen. Meist findet eine Überbestimmung, ausgelöst durch die Messmethode, statt. In Gewebeproben kann eine Unterbestimmung vorliegen, falls nicht alle Zelltypen vom oxidativen Stress betroffen sind. Daher sollte es ein vorrangiges Ziel sein, ein stabileres Oxidationsprodukt des Guanins nachzuweisen, um das Gleichgewicht der DNA-Oxidation und Reparatur besser zu verstehen. KW - Oxidativer Stress KW - Aldosteron KW - Renin-Angiotensin-Aldosteron-System KW - Angiotensin II KW - LC-MS KW - oxidative Stressmarker KW - 8-Oxo-2’-desoxyguanosin KW - Hydroxylradikal KW - DNA-Reparatur KW - Mineralokortikoidrezeptor KW - 8-oxo-2'-deoxyguanosine KW - DNA base excision repair KW - hypertension KW - oxidative stress marker KW - RNA degradation Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-111190 ER - TY - THES A1 - Jakob-Rodamer, Verena T1 - Development and validation of LC-MS/MS methods to determine PK/PD parameters of anti-infectives T1 - Entwicklung und Validierung von LC-MS/MS Methoden zur Bestimmung von PK/PD-Parametern von Antiinfektiva N2 - In the present thesis the development and validation of bioanalytical LC-MS/MS methods for the quantification of erythromycin A, erythromycin ethylsuccinate, roxithromycin, clarithromycin, 14 hydroxy clarithromycin, flucloxacillin, piperacillin and moxifloxacin in human plasma and human urine (piperacillin) is introduced. All methods were applied to analyze human plasma and urine samples from clinical trials and therefore, have been validated according to international guidelines. The methods were reliable in these studies and fulfilled all regulatory requirements known at the time of the study conduct. Moreover, the validation data of the macrolides were compared on three different mass spectrometers (API III Plus, API 3000™, API 5000™). The new innovations in the ion source (horizontal versus vertical electrospray), the ionpath (skimmer, QJet) and the diameter of the orifice resulted in better sensitivity and a larger linearity range for the majority of the analytes. Sensitivity was improved up to a factor of 12 (for clarithromycin) between API III Plus to API 3000™ and up to a factor of 8 (for erythromycin and roxithromycin) between API 3000™ and API 5000™, keeping the accuracy and precision data at about the same level. The high sensitivity was a benefit for example for the flucloxacillin study, because concentrations from all subject samples were detectable up to approximately eight half-lives, i.e. no concentrations needed to be reported below the quantification limit. Also the linearity range were extended from two orders of magnitude to up to four orders of magnitude, which increases the likelihood to allow to analyze all samples from a pharmacokinetic study in the same run. This is especially useful if a large concentration range needs to be analysed, for example, if the method shall be applied in an ascending dose study. Then, all low concentrations from the beginning of the study can be determined, as well as all high concentrations, without the need to dilute and analyse single samples repeatedly. The pharmacokinetic data were compared to previously reported literature data and correlated graphically with MIC values of popular microorganisms which might be a starting point for further PK/PD investigations. The PK/PD theory is a very helpful tool for prediction of the efficacy of given drugs against certain micro-organisms. Depending on the pharmacodynamic processes, e. g. the mode of action, three classes of drugs have been identified. In the same way this applies to adverse effects, which need to be minimised by reducing plasma concentrations. These coherences are not well-investigated, yet, and are not discussed further in this thesis. Still, a lot of research has to be done in this interdisciplinary field to minimise uncertainty in single values, like an AUC/MIC. These include: Improve accuracy and precision of bioanalytical methods determining total and free concentration data in biological matrices for calculation of AUC and Cmax These parameters are related to the MIC in pharmacodynamic considerations. Since the determination of the MIC often underlies significant variations and also differences between microbiological laboratories, the determination of concentrations of anti-infectives is particular important, being achievable by scientific exact techniques. Finally, from the volume of distribution of antibiotics can be used to derive information about intracellular concentrations and effectivity of antiinfectives. N2 - In der vorliegenden Arbeit wird die Entwicklung und Validierung von bioanalytischen LC-MS/MS-Methoden zur Quantifizierung von Erythromycin A, Erythromycin-ethylsuccinat, Roxithromycin, Clarithromycin, 14 Hydroxy-clarithromycin, Flucloxacillin, Piperacillin und Moxifloxacin in Humanplasma und Humanurin (Piperacillin) vorgestellt. Alle Methoden wurden für die Analyse von Plasma- und Urinproben aus klinischen Studien beim Menschen eingesetzt und deshalb nach international anerkannten Richtlinien validiert. In diesen Studien haben sich die Methoden bewährt und alle Anforderungen der zum Zeitpunkt der Studie bekannten behördlichen Ansprüche erfüllt. Die Validierungsdaten der Makrolid-Methoden konnten zudem an drei Massenspektrometern der selben Baureihe verglichen werden. Dabei zeigte sich, dass die Neuerungen an der Ionenquelle (horizontale versus vertikale ESI), dem Ionenpfad (Skimmer, QJet), sowie das immer größere Orifice in der Baureihe, nicht nur stetig verbesserte Sensitivität ermöglichen, sondern auch immer größere Linearitätsbereiche. So konnte ein Sensitivitätsgewinn bis zu Faktor 12 (Clarithromycin) von API III Plus auf API 3000™ und bis zu Faktor 8 (Erythromycin und Roxithromycin) von API 3000™ auf API 5000™ bei etwa gleichen Werten für die Präzision erreicht werden. Die hohe Sensitivität zeigte sich zum Beispiel bei der Flucloxacillin Studie von Vorteil, da alle Konzentrationen bis circa acht Halbwertszeiten nach Wirkstoffgabe bestimmt werden konnten, ohne dass einzelne Proben als „BLOQ“ (unter dem Quantifizierungslimit) berichtet werden mussten. Während früher noch Linearitätsbereiche um zwei Größenordnungen üblich waren, sind jetzt am API 5000™ Konzentrationsbereiche über bis zu vier Größenordnungen reproduzierbar linear. Das ist insbesondere von Nutzen, wenn bei einer Substanz ein größerer Konzentrationsbereich gemessen werden muss. Das ist beispielsweise dann der Fall, wenn die Methode für eine Dosissteigerungsstudie eingesetzt werden soll. Dann können sowohl alle kleinen Konzentrationen zu Beginn der Studie gemessen werden, als auch alle hohen Konzentrationen zum Ende der Studie, und zwar ohne, dass einzelne Proben gesondert verdünnt und wiederholt gemessen werden müssen. Die pharmakokinetischen Daten der Antibiotika wurden in den Kontext mit Literaturdaten gestellt und graphisch mit MHK-Werten für gängige Mikroorganismen verglichen, was den Ausgangspunkt für spätere PK/PD-Untersuchungen darstellt. Für die Vorhersage der Wirksamkeit einer verabreichten Substanz gegenüber bestimmten Mikroorganismen ist die PK/PD-Korrelation ein gutes Hilfsmittel. Anhand der pharmakodynamischen Parameter, wie der Wirkungsweise, können drei Antibiotikaklassen gebildet werden. In analoger Weise gilt für die Nebenwirkungen, dass die Plasma-Konzentrationen verringert werden müssen. Diese Zusammenhänge sind jedoch weniger gut untersucht und werden in dieser Dissertation nicht näher diskutiert. In diesem interdisziplinären Feld ist immer noch viel Forschung nötig um beispielsweise Unsicherheiten bei einzelnen Werten wie z.B. AUC/MIC zu minimieren. Diese beinhalten: Verbesserung der Genauigkeit und Präzision von bioanalytischen Methoden welche für die Bestimmung der Gesamtkonzentration und der freien Konzentration in biologischen Matrices verwendet werden um AUC und Cmax zu bestimmen. Diese Parameter werden in pharmakodynamischen Überlegungen in Beziehung zur MHK gesetzt. Da die MHK-Bestimmung oft erheblichen Schwankungen und auch Unterschieden zwischen verschiedenen mikrobiologischen Laboratorien unterliegt, kommt der Konzentrationsbestimmung der Antibiotika besondere Bedeutung zu, weil sie mit naturwissenschaftlich exakten Methoden möglich ist. Aus den Verteilungsvolumina von Antibiotika lassen sich schließlich auch noch Informationen über die intrazelluläre Konzentration und Wirksamkeit von Antibiotika ableiten. KW - Antimikrobieller Wirkstoff KW - Pharmakokinetik KW - Pharmakodynamik KW - LC-MS KW - LC-MS/MS KW - anti-infectives KW - Antiinfektiva KW - mass spectrometry KW - liquid chromatography KW - antibiotic KW - pharmacokinetic KW - clinical study Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-109215 ER -