TY - JOUR A1 - Brumberg, Joachim A1 - Blazhenets, Ganna A1 - Schröter, Nils A1 - Frings, Lars A1 - Jost, Wolfgang H. A1 - Lapa, Constantin A1 - Meyer, Philipp T. T1 - Imaging cardiac sympathetic innervation with MIBG: linear conversion of the heart-to-mediastinum ratio between different collimators JF - EJNMMI Physics N2 - Background The heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible. Methods We included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure. Results H/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R\(^2\) = 0.99, p < 0.001 and R\(^2\) = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 × H/M-ME + 0.63, R\(^2\) = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 ± 0.04; mean relative absolute error 3.2 ± 2.6%). Conclusions The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions. KW - MIBG KW - collimator KW - heart-to-mediastinum ratio KW - linear conversion Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-221675 VL - 6 ER - TY - JOUR A1 - Rasche, Leo A1 - Kumar, Manoj A1 - Gershner, Grant A1 - Samant, Rohan A1 - Van Hemert, Rudy A1 - Heidemeier, Anke A1 - Lapa, Constantin A1 - Bley, Thorsten A1 - Buck, Andreas A1 - McDonald, James A1 - Hillengass, Jens A1 - Epstein, Joshua A1 - Thanendrarajan, Sharmilan A1 - Schinke, Carolina A1 - van Rhee, Frits A1 - Zangari, Maurizio A1 - Barlogie, Bart A1 - Davies, Faith E. A1 - Morgan, Gareth J. A1 - Weinhold, Niels T1 - Lack of Spleen Signal on Diffusion Weighted MRI is associated with High Tumor Burden and Poor Prognosis in Multiple Myeloma: A Link to Extramedullary Hematopoiesis? JF - Theranostics N2 - Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM. KW - multiple myeloma KW - diffusion weighted mri KW - spleen KW - tumor burden KW - high risk KW - extramedullary hematopoiesis Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-224982 VL - 9 IS - 16 ER - TY - JOUR A1 - Scherthan, Harry A1 - Lee, Jin-Ho A1 - Maus, Emanuel A1 - Schumann, Sarah A1 - Muhtadi, Razan A1 - Chojowski, Robert A1 - Port, Matthias A1 - Lassmann, Michael A1 - Bestvater, Felix A1 - Hausmann, Michael T1 - Nanostructure of clustered DNA damage in leukocytes after in-solution irradiation with the alpha emitter Ra-223 JF - Cancers N2 - Background: Cancer patients are increasingly treated with alpha-particle-emitting radiopharmaceuticals. At the subcellular level, alpha particles induce densely spaced ionizations and molecular damage. Induction of DNA lesions, especially clustered DNA double-strand breaks (DSBs), threatens a cell's survival. Currently, it is under debate to what extent the spatial topology of the damaged chromatin regions and the repair protein arrangements are contributing. Methods: Super-resolution light microscopy (SMLM) in combination with cluster analysis of single molecule signal-point density regions of DSB repair markers was applied to investigate the nano-structure of DNA damage foci tracks of Ra-223 in-solution irradiated leukocytes. Results: Alpha-damaged chromatin tracks were efficiently outlined by γ-H2AX that formed large (super) foci composed of numerous 60–80 nm-sized nano-foci. Alpha damage tracks contained 60–70% of all γ-H2AX point signals in a nucleus, while less than 30% of 53BP1, MRE11 or p-ATM signals were located inside γ-H2AX damage tracks. MRE11 and p-ATM protein fluorescent tags formed focal nano-clusters of about 20 nm peak size. There were, on average, 12 (±9) MRE11 nanoclusters in a typical γ-H2AX-marked alpha track, suggesting a minimal number of MRE11-processed DSBs per track. Our SMLM data suggest regularly arranged nano-structures during DNA repair in the damaged chromatin domain. KW - complex DNA damage KW - DNA repair KW - high LET irradiation KW - Single Molecule Localization Microscopy (SMLM) KW - DSB focus substructure Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-193038 SN - 2072-6694 VL - 11 IS - 12 ER - TY - JOUR A1 - Da Vià, Matteo Claudio A1 - Solimando, Antonio Giovanni A1 - Garitano-Trojaola, Andoni A1 - Barrio, Santiago A1 - Munawar, Umair A1 - Strifler, Susanne A1 - Haertle, Larissa A1 - Rhodes, Nadine A1 - Vogt, Cornelia A1 - Lapa, Constantin A1 - Beilhack, Andreas A1 - Rasche, Leo A1 - Einsele, Hermann A1 - Kortüm, K. Martin T1 - CIC Mutation as a Molecular Mechanism of Acquired Resistance to Combined BRAF‐MEK Inhibition in Extramedullary Multiple Myeloma with Central Nervous System Involvement JF - The Oncologist N2 - Combined MEK‐BRAF inhibition is a well‐established treatment strategy in BRAF‐mutated cancer, most prominently in malignant melanoma with durable responses being achieved through this targeted therapy. However, a subset of patients face primary unresponsiveness despite presence of the activating mutation at position V600E, and others acquire resistance under treatment. Underlying resistance mechanisms are largely unknown, and diagnostic tests to predict tumor response to BRAF‐MEK inhibitor treatment are unavailable. Multiple myeloma represents the second most common hematologic malignancy, and point mutations in BRAF are detectable in about 10% of patients. Targeted inhibition has been successfully applied, with mixed responses observed in a substantial subset of patients mirroring the widespread spatial heterogeneity in this genomically complex disease. Central nervous system (CNS) involvement is an extremely rare, extramedullary form of multiple myeloma that can be diagnosed in less than 1% of patients. It is considered an ultimate high‐risk feature, associated with unfavorable cytogenetics, and, even with intense treatment applied, survival is short, reaching less than 12 months in most cases. Here we not only describe the first patient with an extramedullary CNS relapse responding to targeted dabrafenib and trametinib treatment, we furthermore provide evidence that a point mutation within the capicua transcriptional repressor (CIC) gene mediated the acquired resistance in this patient. KW - Multiple myeloma KW - Extramedullary disease KW - Capicua transcriptional repressor KW - Drug resistance KW - BRAF mutation Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-219549 VL - 25 IS - 2 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Wakabayashi, Hiroshi A1 - Chen, Xinyu A1 - Hayakawa, Nobuyuki A1 - Lapa, Constantin A1 - Rowe, Steven P. A1 - Javadi, Mehrbod S. A1 - Robinson, Simon A1 - Higuchi, Takahiro T1 - Ventricular distribution pattern of the novel sympathetic nerve PET radiotracer \(^{18}\)F-LMI1195 in Rabbit Hearts JF - Scientific Reports N2 - We aimed to determine a detailed regional ventricular distribution pattern of the novel cardiac nerve PET radiotracer \(^{18}\)F-LMI1195 in healthy rabbits. Ex-vivo high resolution autoradiographic imaging was conducted to identify accurate ventricular distribution of \(^{18}\)F-LMI1195. In healthy rabbits, \(^{18}\)F-LMI1195 was administered followed by the reference perfusion marker \(^{201}\)Tl for a dual-radiotracer analysis. After 20 min of \(^{18}\)F-LMI1195 distribution time, the rabbits were euthanized, the hearts were extracted, frozen, and cut into 20-μm short axis slices. Subsequently, the short axis sections were exposed to a phosphor imaging plate to determine \(^{18}\)F-LMI1195 distribution (exposure for 3 h). After complete \(^{18}\)F decay, sections were re-exposed to determine 201Tl distribution (exposure for 7 days). For quantitative analysis, segmental regions of Interest (ROIs) were divided into four left ventricular (LV) and a right ventricular (RV) segment on mid-ventricular short axis sections. Subendocardial, mid-portion, and subepicardial ROIs were placed on the LV lateral wall. \(^{18}\)F-LMI1195 distribution was almost homogeneous throughout the LV wall without any significant differences in all four LV ROIs (anterior, posterior, septal and lateral wall, 99 ± 2, 94 ± 5, 94 ± 4 and 97 ± 3%LV, respectively, n.s.). Subepicardial \(^{201}\)Tl uptake was significantly lower compared to the subendocardial portion (subendocardial, mid-portion, and subepicardial activity: 90 ± 3, 96 ± 2 and *80 ± 5%LV, respectively, *p < 0.01 vs. mid-portion). This was in contradistinction to the transmural wall profile of \(^{18}\)F-LMI1195 (90 ± 4, 96 ± 5 and 84 ± 4%LV, n.s.). A slight but significant discrepant transmural radiotracer distribution pattern of \(^{201}\)Tl in comparison to \(^{18}\)F-LMI1195 may be a reflection of physiological sympathetic innervation and perfusion in rabbit hearts. KW - Cardiovascular diseases KW - Heart failure Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-202707 VL - 9 ER - TY - JOUR A1 - Breun, Maria A1 - Monoranu, Camelia M. A1 - Kessler, Almuth F. A1 - Matthies, Cordula A1 - Löhr, Mario A1 - Hagemann, Carsten A1 - Schirbel, Andreas A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Buck, Andreas K. A1 - Wester, Hans-Jürgen A1 - Ernestus, Ralf-Ingo A1 - Lapa, Constantin T1 - [\(^{68}\)Ga]-Pentixafor PET/CT for CXCR4-mediated imaging of vestibular schwannomas JF - Frontiers in Oncology N2 - We have recently demonstrated CXCR4 overexpression in vestibular schwannomas (VS). This study investigated the feasibility of CXCR4-directed positron emission tomography/computed tomography (PET/CT) imaging of VS using the radiolabeled chemokine ligand [\(^{68}\)Ga]Pentixafor. Methods: 4 patients with 6 primarily diagnosed or pre-treated/observed VS were enrolled. All subjects underwent [\(^{68}\)Ga]Pentixafor PET/CT prior to surgical resection. Images were analyzed visually and semi-quantitatively for CXCR4 expression including calculation of tumor-to-background ratios (TBR). Immunohistochemistry served as standard of reference in three patients. Results: [\(^{68}\)Ga]Pentixafor PET/CT was visually positive in all cases. SUV\(_{mean}\) and SUV\(_{max}\) were 3.0 ± 0.3 and 3.8 ± 0.4 and TBR\(_{mean}\) and TBR\(_{max}\) were 4.0 ± 1.4 and 5.0 ± 1.7, respectively. Histological analysis confirmed CXCR4 expression in tumors. Conclusion: Non-invasive imaging of CXCR4 expression using [\(^{68}\)Ga]Pentixafor PET/CT of VS is feasible and could prove useful for in vivo assessment of CXCR4 expression. KW - vestibular schwannoma KW - CXCR4 KW - PET/CT KW - molecular imaging KW - Pentixafor Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-201863 VL - 9 IS - 503 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Kircher, Stefan A1 - Higuchi, Takahiro A1 - Kircher, Malte A1 - Schirbel, Andreas A1 - Wester, Hans-Jürgen A1 - Buck, Andreas K. A1 - Pomper, Martin G. A1 - Rowe, Steven P. A1 - Lapa, Constantin T1 - CXCR4-directed imaging in solid tumors JF - Frontiers in Oncology N2 - Despite histological evidence in various solid tumor entities, available experience with CXCR4-directed diagnostics and endoradiotherapy mainly focuses on hematologic diseases. With the goal of expanding the application of CXCR4 theranostics to solid tumors, we aimed to elucidate the feasibility of CXCR4-targeted imaging in a variety of such neoplasms. Methods: Nineteen patients with newly diagnosed, treatment-naïve solid tumors including pancreatic adenocarcinoma or neuroendocrine tumor, cholangiocarcinoma, hepatocellular carcinoma, renal cell carcinoma, ovarian cancer, and prostate cancer underwent [\(^{68}\)Ga]Pentixafor PET/CT. CXCR4-mediated uptake was assessed both visually and semi-quantitatively by evaluation of maximum standardized uptake values (SUV\(_{max}\)) of both primary tumors and metastases. With physiologic liver uptake as reference, tumor-to-background ratios (TBR) were calculated. [\(^{68}\)Ga]Pentixafor findings were further compared to immunohistochemistry and [\(^{18}\)F]FDG PET/CT. Results: On [\(^{68}\)Ga]Pentixafor PET/CT, 10/19 (52.6%) primary tumors were visually detectable with a median SUVmax of 5.4 (range, 1.7–16.0) and a median TBR of 2.6 (range, 0.8–7.4), respectively. The highest level of radiotracer uptake was identified in a patient with cholangiocarcinoma (SUVmax, 16.0; TBR, 7.4). The relatively low uptake on [\(^{68}\)Ga]Pentixafor was also noted in metastases, exhibiting a median SUVmax of 4.5 (range, 2.3–8.8; TBR, 1.7; range, 1.0–4.1). A good correlation between uptake on [\(^{68}\)Ga]Pentixafor and histological derived CXCR4 expression was noted (R = 0.62, P < 0.05). In the 3 patients in whom [\(^{18}\)F]FDG PET/CT was available, [\(^{68}\)Ga]Pentixafor exhibited lower uptake in all lesions. Conclusions: In this cohort of newly diagnosed, treatment-naïve patients with solid malignancies, CXCR4 expression as detected by [\(^{68}\)Ga]Pentixafor-PET/CT and immunohistochemistry was rather moderate. Thus, CXCR4-directed imaging may not play a major role in the management of solid tumors in the majority of patients. KW - CXCR4 KW - [68Ga]Pentixafor KW - theranostics KW - solid tumors KW - chemokine receptor Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-195678 SN - 2234-943X VL - 9 IS - 770 ER - TY - THES A1 - Soares Machado, Jéssica T1 - Dosimetry-based Assessment of Radiation-associated Cancer risk for \(^9\)\(^9\)\(^m\)Tc-MAG3 Scans in Infants and Optimization of Administered Activities for \(^6\)\(^8\)Ga-labelled Peptides in Children and Adolescents T1 - Dosimetrie-basierte Abschätzung des strahlungsassoziierten Krebsrisikos für \(^9\)\(^9\)\(^m\)Tc-MAG3-Scans bei Säuglingen und Optimierung der verabreichten Aktivitäten für \(^6\)\(^8\)Ga-markierte Peptide bei Kindern und Jugendlichen N2 - In 2006, 0.18 Mio pediatric nuclear medicine diagnostic exams were performed worldwide. However, for most of the radiopharmaceuticals used data on biokinetics and, as a consequence on dosimetry, are missing or have not been made publicly available. Therefore, most of the dosimetry assessments presented today for diagnostic agents in children and adolescents rely on the biokinetics data of adults. Even for one of the most common nuclear medicine exams for this patient group, renal scintigraphy with 99mTc-MAG3 for assessing renal function measured data on biokinetics is available only from a study performed on four children of different ages. In particular, renal scans are among the most frequent exams performed on infants and toddlers. Due to the young age, this patient group can be classified as a risk group with a higher probability of developing stochastic radiation effects compared to adults. As there are only limited data on biokinetics and dosimetry in this patient group, the aim of this study is to reassess the dosimetry and the associated radiation risk for a larger number of infants undergoing 99mTc-MAG3 renal scans based on a retrospective analysis of existing patient data. Data were collected retrospectively from 34 patients younger than 20 months with normal (20 patients) and abnormal renal function (14 patients) undergoing 99mTc-MAG3 scans. The patient-specific organ activity was estimated based on a retrospective calibration which was performed based on a set of two 3D-printed infant kidneys (newborns: 8.6 ml; 1-year-old: 23.4 ml) filled with known activities. Both phantoms were scanned at different positions along the anteroposterior axis inside a water phantom, providing depth- and size-dependent attenuation correction factors for planar imaging. Time-activity curves were determined by drawing kidney, bladder, and whole body regions-of-interest for each patient, and subsequently applying the calibration factor for conversion of counts to activity. Patient-specific time-integrated activity coefficients were obtained by integrating the organ-specific time-activity curves. Absorbed and effective dose coefficients for each patient were assessed with OLINDA/EXM for the provided newborn and 1-year-old phantom. Based on absorbed dose values, the radiation risk estimation was performed individually for each of the 34 patients with the National Cancer Institute’s Radiation Risk Assessment Tool. The patients’ organ-specific mean absorbed dose coefficients for the patients with normal renal function were 0.04±0.03 mGy/MBq for the kidneys and 0.27±0.24 mGy/MBq for the bladder. This resulted in a mean effective dose coefficient of 0.02±0.02 mSv/MBq. Based on the dosimetry results, the evaluation of the excess lifetime risk (ELR) for the development of radiation-induced cancer showed that the group of newborns has an ELR of 16.8 per 100,000 persons, which is higher in comparison with the 1-year-old group with an ELR of 14.7 per 100,000 persons. With regard to the 14 patients with abnormal renal function, the mean values for the organ absorbed dose coefficients for the patients were: 0.40±0.34 mGy/MBq for the kidneys and 0.46±0.37 mGy/MBq for the bladder. The corresponding effective dose coefficients (mSv/MBq) was: 0.05±0.02 mSv/MBq. The mean ELR (per 100,000 persons) for developing cancer from radiation exposure for patients with abnormal renal function was 29.2±18.7 per 100,000 persons. As a result, the radiation-associated stochastic risk increases with the organ doses, taking age- and gender-specific influences into account. Overall, the lifetime radiation risk associated with the 99mTc-MAG3 scans is very low in comparison to the general population risk for developing cancer. Furthermore, due to the increasing demand for PET-scans in children and adolescents with 68Ga-labelled peptides, in this work published data sets for those compounds were analyzed to derive recommendations for the administered activities in children and adolescents. The recommendation for the activities to be administered were based on the weight-independent effective dose model, proposed by the EANM Pediatric Dosage Card for application in pediatric nuclear medicine. The aim was to derive recommendations on administered activities for obtaining age-independent effective doses. Consequently, the corresponding weight-dependent effective dose coefficients were rescaled according to the formalism of the EANM dosage card, to determine the radiopharmaceutical class of 68Ga-labeled peptides (“multiples”), and to calculate the baseline activities based on the biokinetics of these compounds and an upper limit of the administered activity of 185 MBq for an adult. Analogous to 18F-fluoride, a minimum activity of 14 MBq is recommended. As a result, for those pediatric nuclear medicine applications involving 68Ga-labeled peptides, new values for the EANM dosage card were proposed and implemented based on the results derived in this work. Overall, despite the low additional radiation-related cancer risk, all efforts should be undertaken to optimize administered activities in children and adolescents for obtaining sufficient diagnostic information with minimal associated radiation risk. N2 - Im Jahr 2006 wurden weltweit 0,18 Mio. nuklearmedizinische Diagnostikuntersuchungen bei Kindern durchgeführt. Für die meisten Radiopharmazeutika fehlen jedoch Daten zur Biokinetik und damit zur Dosimetrie oder diese wurden nicht öffentlich zugänglich gemacht. Daher basieren die meisten der heute vorgestellten Dosimetriedaten für Diagnostika bei Kindern und Jugendlichen auf den biokinetischen Daten von Erwachsenen. Selbst für eine der häufigsten nuklearmedizinischen Untersuchungen für diese Patientengruppe, die Nierenszintigraphie mit 99mTc-MAG3 für Bestimmung der Nierenfunktion, wurden Daten zur Biokinetik bisher nur für vier Kinder unterschiedlichen Alters erhoben. Insbesondere Nierenuntersuchungen gehören zu den häufigsten Untersuchungen bei Säuglingen und Kleinkindern. Aufgrund des jungen Alters kann diese Patientengruppe als Hochrisikogruppe mit einer höheren Wahrscheinlichkeit für das Eintreten stochastischer Strahlenwirkungen im Vergleich zu Erwachsenen eingestuft werden. Da es in dieser Patientengruppe nur begrenzte Daten zur Biokinetik und Dosimetrie gibt, ist das Ziel dieser Arbeit, die Dosimetrie und das damit verbundene Strahlenrisiko für eine größere Anzahl von Kleinkindern, die sich 99mTc-MAG3-Nierenscans unterziehen, auf der Grundlage einer retrospektiven Analyse bestehender Patientendaten neu zu bewerten. Die Daten wurden retrospektiv von 34 Patienten unter 20 Monaten mit normaler (20 Patienten) und eingeschränkter Nierenfunktion (14 Patienten) erhoben, bei denen 99mTc-MAG3-Scans durchgeführt wurden. Die patientenspezifische Organaktivität wurde basierend auf einer retrospektiven Kalibrierung abgeschätzt. Diese Kalibrierung basiert auf einem Satz von zwei 3D-gedruckten Säuglingsnieren, die mit bekannten Aktivitäten gefüllt wurden. Beide Phantome wurden an verschiedenen Positionen entlang der anteroposterioren Achse innerhalb eines Wasserphantoms gescannt und lieferten tiefen- und größenabhängige Schwächungskorrekturfaktoren für die planare Bildgebung. Die Zeit-Aktivitäts-Kurven wurden bestimmt, indem für jeden Patienten Nieren-, Blasen- und Ganzkörperregionen eingezeichnet und anschließend der entsprechende Kalibrierfaktor für die Umwandlung der Zählraten in Aktivität angewendet wurde. Patientenspezifische zeitintegrierte Aktivitätskoeffizienten wurden durch Integration der organspezifischen Zeit-Aktivitätskurven ermittelt. Die Energie- und effektiven Dosiskoeffizienten für jeden Patienten wurden mit OLINDA/EXM für das bereitgestellte Neugeborenen- und 1-Jahres-Phantom ermittelt. Basierend auf diesen Werten für die Energiedosen wurde eine individuelle Abschätzung des Strahlenrisikos für jeden der 34 Patienten mit dem Radiation Risk Assessment Tool des National Cancer Institute durchgeführt. Die organspezifischen mittleren Energiedosiskoeffizienten der Patienten mit normaler Nierenfunktion lagen bei 0,04±0,03 mGy/MBq für die Nieren und 0,27±0,24 mGy/MBq für die Blase, was in einem mittleren effektiven Dosiskoeffizienten von 0,02±0,02 mSv/MBq resultiert. Basierend auf den Ergebnissen der Dosimetrie, zeigte die Auswertung des zusätzlichen Lebenszeitrisikos ("excess lifetime risk", ELR) für die Entwicklung von strahleninduziertem Krebs, dass die Gruppe der Neugeborenen ein ELR von 16,8 pro 100.000 Personen aufweist, was höher ist als das der Gruppe der 1-jährigen mit 14,7 pro 100.000 Personen. Bei den 14 Patienten mit abnormaler Nierenfunktion waren die Mittelwerte für die Koeffizienten der organspezifischen Energiedosen für die Patienten: 0,40±0,34 mGy/MBq für die Nieren; 0,46±0,37 mGy/MBq für die Blase. Der effektivendosiskoeffizienten (mSv/MBq) waren: 0,05±0,02 mSv/MBq. Der mittlere ELR (pro 100.000 Personen) für die Entstehung von Krebs durch die Strahlenexposition von Patienten mit abnormaler Nierenfunktion betrug 29,2±18,7 pro 100.000 Personen. Das mit der Strahlung verbundene stochastische Risiko steigt mit den Organdosen unter Berücksichtigung alters- und geschlechtsspezifischer Einflüsse. Im Allgemeinen ist das mit den 99mTc-MAG3-Scans verbundene lebenslange Strahlenrisiko im Vergleich zum allgemeinen Bevölkerungsrisiko für die Entstehung von Krebs sehr gering. Aufgrund der steigenden Nachfrage nach PET-Scans bei Kindern und Jugendlichen mit 68Ga-markierten Peptiden wurden zusätzlich publizierte Datensätze für diese Verbindungen analysiert, um Empfehlungen für zu verabreichende Aktivitäten bei Kindern und Jugendlichen abzuleiten. Die Dosisberechnungen dazu basierten auf dem Modell einer gewichtsunabhängigen effektiven Dosis, das von der EANM Pediatric Dosage Card für den Einsatz in der pädiatrischen Nuklearmedizin vorgeschlagen wurde. Ziel war es, Empfehlungen zu verabreichenden Aktivitäten so aufzuteilen, dass sich altersunabhängige effektive Dosen ergeben. Dazu wurden die entsprechenden gewichtsabhängigen effektiven Dosiskoeffizienten gemäß dem Formalismus der EANM-Dosierungsempfehlung neu berechnet, um die radiopharmazeutische Klasse der 68Ga-markierten Peptide ("Multiples") zu bestimmen und die Werte für Basisaktivität zu berechnen. Diese basierend auf den Biokinetiken dieser Verbindungen und einer Obergrenze der verabreichten Aktivität von 185 MBq für einen Erwachsenen. Analog zu 18F-Fluorid, wird eine Mindestaktivität von 14 MBq empfohlen. Darauf basierend wurden für die pädiatrischen nuklearmedizinischen Anwendungen mit 68Ga-markierten Peptiden neue Werte für die EANM-Dosierungsempfehlung vorgeschlagen. Insgesamt sollten, trotz des geringen zusätzlichen strahlenbedingten Krebsrisikos, alle Anstrengungen unternommen werden, um die verabreichten Aktivitäten bei Kindern und Jugendlichen zu optimieren, um ausreichende diagnostische Informationen bei minimalem zusätzlichem Strahlenrisiko zu erhalten. KW - Biokinetics KW - Absorbed Doses KW - Risk Assessment KW - Pediatric Patients KW - Dosimetry KW - Nuclear Medicine KW - Pediatric Nuclear Medicine KW - Diagnostic Imaging Exams KW - Radiation Protection KW - Administered Activities KW - Radiation-associated Cancer Risk KW - Ga-68-labelled Peptides KW - Tc-99m-MAG3 Scans Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-192640 ER - TY - THES A1 - Brumberg [geb. Ichouh], Dalma T1 - \(^{11}\)C-MET und \(^{18}\)F-FDG: \(In\) \(vitro\) Vergleich zur Bildgebung beim Multiplen Myelom im Kontext biologischer Charakteristika T1 - Imaging multiple myeloma with \(^{11}\)C-MET and \(^{18}\)F-FDG: \(In\) \(vitro\) comparison in the context of biological characteristics N2 - Das Multiple Myelom ist eine hämatologische Erkrankung, die durch die Proliferation von Plasmazellen und die Produktion von Antikörpern oder deren Leichtketten gekennzeichnet ist. Eine frühe Diagnosestellung durch Detektion sowohl intra- als auch extramedullärer Manifestationen ist für die Einleitung einer effektiven Therapie von entscheidender Bedeutung. Ebenso bedeutsam ist ein wirksames Therapiemonitoring. Wichtige diagnostische Modalitäten sind bei beiden Fragestellungen tomografische, bildgebende Verfahren. Hierbei wurde die Effektivität der 18F-FDG-PET/CT im Rahmen der Diagnose, des Stagings und der Prognoseabschätzung bereits nachgewiesen. Dennoch ist ihr klinischer Nutzen durch die geringe Sensitivität bei Detektion von diffusem Knochenmarksbefall und Vorliegen sowohl falsch positiver als auch falsch negativer Befunde limitiert. Die vorliegende Arbeit hat untersucht, ob der aminosäurebasierte Tracer 11C-MET über spezifische Eigenschaften verfügt, die eine höhere Sensitivität und Spezifität in der Detektion von Myelomzellen ermöglichen und ob der Radioligand dem etablierten Glukoseanalogon 18F-FDG überlegen ist. Hierfür wurden drei etablierte humane Myelomzelllinien, sowohl nativ als auch nach 48-stündiger Therapie mit dem Proteasominhibitor Carfilzomib, mit 18F-FDG und 11C-MET inkubiert und mithilfe eines Gammastrahlungszählers beurteilt. Zudem wurde untersucht, ob die Traceraufnahme mit spezifischen Charakteristika der Tumorbiologie korreliert. So wurde die Oberflächenexpression von CD138 und CXCR4, die intrazelluläre Expression der Leichtketten κ/λ und die Proliferation der Zelllinien mittels Durchflusszytometrie vor und nach Behandlung mit Carfilzomib eruiert. Die unbehandelten Zellen zeigten, verglichen zu 18F-FDG, bereits nach kürzester Inkubationsdauer eine 3-3,5-fach höhere 11C-MET Retention. Weiterhin zeigte sich die 11C-MET-Aufnahme nach Behandlung aller Zellreihen insgesamt marginal höher als die 18F-FDG-Aufnahme, während die Reduktion der 11C-MET-Anreicherung im prä- zu posttherapeutischen Vergleich für alle drei Zelllinien signifikant war. Eine mögliche Erklärung für diese Beobachtungen liefert die Myelombiologie: eine erhöhte Aufnahme der radioaktiv markierten Aminosäure durch MM-Zellen könnte durch eine Zunahme der Zellproliferation und insbesondere durch eine Steigerung der Proteinsynthese im Rahmen der überschießenden Produktion von M-Protein bedingt sein. In Zusammenschau könnte 11C-MET mit höherer Sensitivität Myelommanifestationen detektieren, wodurch ggf. Läsionen mit geringem Metabolismus dargestellt und eine bessere Beurteilung des Krankheitspogresses erfolgen könnte. Zudem bietet für den klinischen Einsatz die – verglichen zu 18F-FDG – größere Differenz der 11C-MET-Retention zwischen prä- und posttherapeutischer Messung die Möglichkeit einer besseren Beurteilbarkeit des Therapieansprechens. 11C-MET birgt ggf. das Potential auch minimale aktive Restherde zu detektieren und damit Patienten einem individualisierten Therapiekonzept zuzuführen. Ein Zusammenhang zwischen den untersuchten Biomarkern und der 11C-MET Retention bzw. deren Abnahme nach Behandlung konnte nicht gezeigt werden. Somit sollten für 11C-MET andere Biomarker herangezogen werden, um diese mit der Bildgebung zu korrelieren und zu bewerten. N2 - Multiple myeloma is a heterogeneous lymphoproliferative disease, which is characterized by an uncontrolled proliferation of clonal plasma cells. It is both essential to diagnose the disease at an early stage in order to prevent organ damage and to monitor therapy to adjust and individualize it. Imaging modalities like 18F-FDG-PET/CT play an important role for these purposes. However, its clinical benefit is limited due to the low detection rate of diffuse bone marrow invasion and false positive or negative findings. To overcome these limitations, we analysed if the amino acid-based tracer 11C-MET has specific features to reach a higher sensitivity and specificity in detecting myeloma cells. Therefore, three established human myeloma cell lines were incubated with 18F-FDG and 11C-MET natively without and after therapy with the proteasome inhibitor Carfilzomib and evaluated via gamma counter. The results showed a higher 11C-MET-uptake in untreated cells after a short time, a higher uptake after treatment with Carfilzomib and a significant reduction pre- to post therapy compared to 18F-FDG. These results assume that 11C-MET has the potential to be more sensitive in detecting myeloma manifestations as well as for the monitoring of disease activity during and after treatment. Furthermore, it might also have the potential to visualize minimal residual disease after treatment. This could lead to an early adaption of therapy and thereby may extend progression free survival. This study also investigated the relationship between specific biological characteristics of multiple myeloma (surface expression of CD138 and CXCR4, intracellular light chain production and proliferation rate) and radioligand uptake. A correlation between the markers and the uptake could not be proven, so that we assume that other biomarkers should be considered and correlated with 11C-MET to reflect tumor biology and verify possible prognostic markers. KW - Multiples Myelom KW - 11C-Methionin KW - Positronenemissionstomographie KW - 18F-FDG KW - CD138 KW - CXCR4 Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-181843 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Ordonez, Alvaro A. A1 - Sanchez-Bautista, Julian A1 - Marcus, Charles A1 - Lapa, Constantin A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Leal, Jeffrey P. A1 - Lodge, Martin A. A1 - Javadi, Mehrbod S. A1 - Jain, Sanjay K. A1 - Higuchi, Takahiro T1 - Novel functional renal PET imaging with 18F-FDS in human subjects JF - Clinical Nuclear Medicine N2 - The novel PET probe 2-deoxy-2-18F-fluoro-D-sorbitol (18F-FDS) has demonstrated favorable renal kinetics in animals. We aimed to elucidate its imaging properties in two human volunteers. 18F-FDS was produced by a simple one-step reduction from 18F-FDG. On dynamic renal PET, the cortex was delineated and activity gradually transited in the parenchyma, followed by radiotracer excretion. No adverse effects were reported. Given the higher spatiotemporal resolution of PET relative to conventional scintigraphy, 18F-FDS PET offers a more thorough evaluation of human renal kinetics. Due to its simple production from 18F-FDG, 18F-FDS is virtually available at any PET facility with radiochemistry infrastructure. KW - 2-deoxy-2-18F-fluoro-D-sorbitol KW - Positronen-Emissions-Tomografie KW - 18F-FDS KW - renal imaging KW - Positron-Emission Tomography KW - split renal function KW - kidney Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-174634 SN - 0363-9762 VL - 44 IS - 5 ER -