TY - JOUR A1 - Rudert, Maximilian A1 - Holzapfel, Boris Michael A1 - Jakubietz, Michael T1 - Adjuvant Radiotherapy JF - Deutsches Ärzteblatt International N2 - No abstract available. KW - Soft-tissue sarcoma Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-133571 VL - 108 IS - 33 ER - TY - JOUR A1 - Lüdemann, Martin A1 - Jakuscheit, Axel A1 - Ewald, Andrea A1 - Frühmann, Leena A1 - Hölscher-Doht, Stefanie A1 - Rudert, Maximilian A1 - von Hertzberg-Boelch, Sebastian Philipp T1 - Influence of Tranexamic Acid on Elution Characteristics and Compressive Strength of Antibiotic-Loaded PMMA-Bone Cement with Gentamicin JF - Materials N2 - Purpose: The topical application of tranexamic acid (TXA) into the joint space during total joint arthroplasty (TJA) with no increase of complications, has been widely reported. We investigated the influence of TXA on antibiotic release, activity of the released antibiotic against a clinical isolate of S. aureus, and compressive strength of a widely used commercially prepared gentamicin-loaded cement brand (PALACOS R + G). Method: 12 bone cement cylinders (diameter and height = 6 and 12 mm, respectively) were molded. After curing in air for at least 1 h, six of the cylinders were completely immersed in 5 mL of fetal calf serum (FCS) and the other six were completely immersed in a solution consisting of 4.9 mL of FCS and 0.1 mL (10 mg) of TXA. Gentamicin elution tests were performed over 7 d. Four hundred µL of the gentamicin eluate were taken every 24 h for the first 7 d without renewing the immersion fluid. The gentamicin concentration was determined in a clinical analyzer using a homogeny enzyme immuno-assay. The antimicrobial activity of the eluate, obtained after day 7, was tested. An agar diffusion test regime was used with Staphylococcus aureus. Bacteria were grown in a LB medium and plated on LB agar plates to get a bacterial lawn. Fifty µL of each eluate were pipetted on 12-mm diameter filter discs, which were placed in the middle of the agar gel. After 24 h of cultivation at 37 °C, the zone of inhibition (ZOI) for each specimen was measured. The compressive strength of the cements was determined per ISO 5833. Results: At each time point in the gentamicin release test, the difference in gentamicin concentration, obtained from specimens immersed in the FCS solution only and those immersed in the FCS + TXA solution was not significant (p = 0.055–0.522). The same trend was seen in each of the following parameters, after 7 d of immersion: (1) Cumulative gentamicin concentration (p < 0.297); (2) gentamicin activity against S. aureus (strongly visible); (3) ZOI size (mostly > 20 mm) (p = 0.631); and (4) compressive strength (p = 0.262). Conclusions: For the PALACOS R + G specimens, the addition of TXA to FCS does not produce significant decreases in gentamicin concentration, in the activity of the gentamicin eluate against a clinical isolate of S. aureus, the zone of inhibition of S. aureus, and in the compressive strength of the cement, after 7 d of immersion in the test solution. KW - gentamicin-loaded poly (methyl methacrylate) bone cement KW - total joint arthroplasty KW - total knee arthroplasty KW - tranexamic acid Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-246236 SN - 1996-1944 VL - 14 IS - 19 ER - TY - JOUR A1 - Jakuscheit, Axel A1 - Schaefer, Nina A1 - Roedig, Johannes A1 - Luedemann, Martin A1 - Hertzberg-Boelch, Sebastian Philipp von A1 - Weissenberger, Manuel A1 - Schmidt, Karsten A1 - Holzapfel, Boris Michael A1 - Rudert, Maximilian T1 - Modifiable individual risks of perioperative blood transfusions and acute postoperative complications in total hip and knee arthroplasty JF - Journal of Personalized Medicine N2 - Background: The primary aim of this study was to identify modifiable patient-related predictors of blood transfusions and perioperative complications in total hip and knee arthroplasty. Individual predictor-adjusted risks can be used to define preoperative treatment thresholds. Methods: We performed this retrospective monocentric study in orthopaedic patients who underwent primary total knee or hip arthroplasty. Multivariate logistic regression models were used to assess the predictive value of patient-related characteristics. Predictor-adjusted individual risks of blood transfusions and the occurrence of any perioperative adverse event were calculated for potentially modifiable risk factors. Results: 3754 patients were included in this study. The overall blood transfusion and complication rates were 4.8% and 6.4%, respectively. Haemoglobin concentration (Hb, p < 0.001), low body mass index (BMI, p < 0.001) and estimated glomerular filtration rate (eGFR, p = 0.004) were the strongest potentially modifiable predictors of a blood transfusion. EGFR (p = 0.001) was the strongest potentially modifiable predictor of a complication. Predictor-adjusted risks of blood transfusions and acute postoperative complications were calculated for Hb and eGFR. Hb = 12.5 g/dL, BMI = 17.6 kg/m\(^2\), and eGFR = 54 min/mL were associated, respectively, with a 10% risk of a blood transfusion, eGFR = 59 mL/min was associated with a 10% risk of a complication. Conclusion: The individual risks for blood transfusions and acute postoperative complications are strongly increased in patients with a low preoperative Hb, low BMI or low eGFR. We recommend aiming at a preoperative Hb ≥ 13g/dL, an eGFR ≥ 60 mL/min and to avoid a low BMI. Future studies must show if a preoperative increase of eGFR and BMI is feasible and truly beneficial. KW - patient blood management KW - total joint arthroplasty KW - haemoglobin KW - perioperative management Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-250290 SN - 2075-4426 VL - 11 IS - 11 ER - TY - JOUR A1 - Boelch, Sebastian P. A1 - Rueckl, Kilian A1 - Fuchs, Clara A1 - Jordan, Martin A1 - Knauer, Markus A1 - Steinert, Andre A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Comparison of elution characteristics and compressive strength of biantibiotic-loaded PMMA bone cement for spacers: Copal\(^®\) spacem with gentamicin and vancomycin versus Palacos\(^®\) R+G with vancomycin JF - BioMed Research International N2 - Purpose. Copal\(^®\) spacem is a new PMMA bone cement for fabricating spacers. This study compares elution of gentamicin, elution of vancomycin, and compressive strength of Copal\(^®\) spacem and of Palacos\(^®\) R+G at different vancomycin loadings in the powder of the cements. We hypothesized that antibiotic elution of Copal\(^®\) spacem is superior at comparable compressive strength. Methods. Compression test specimens were fabricated using Copal\(^®\) spacem manually loaded with 0.5 g gentamicin and additionally 2 g, 4 g, and 6 g of vancomycin per 40 g of cement powder (COP specimens) and using 0.5 g gentamicin premixed Palacos\(^®\) R+G manually loaded with 2 g, 4 g, and 6 g of vancomycin per 40 g of cement powder (PAL specimens). These specimens were used for determination of gentamicin and vancomycin elution (in fetal calf serum, at 22°C) and for determination of compressive strength both prior and following the elution tests. Results. Cumulative gentamicin concentrations (p < 0.005) and gentamicin concentration after 28 days (p ≤ 0.043) were significantly lower for COP specimens compared to PAL specimens. Cumulative vancomycin concentrations were significantly higher (p ≤ 0.043) for COP specimens after the second day. Vancomycin concentrations after 28 days were not significantly higher for the Copal specimens loaded with 2 g and 4 g of vancomycin. Compressive strength was not significantly different between COP specimens and PAL specimens before elution tests. Compressive strength after the elution tests was significantly lower (p = 0.005) for COP specimens loaded with 2 g of vancomycin. Conclusion. We could not demonstrate consistent superior antibiotic elution from Copal\(^®\) spacem compared to Palacos\(^®\) R+G for fabricating gentamicin and vancomycin loaded spacers. The results do not favor Copal\(^®\) spacem over Palacos\(^®\) R+G for the use as a gentamicin and vancomycin biantibiotic-loaded spacer. KW - Copal\(^®\) spacem KW - PMMA bone cement KW - elution KW - compressive strength Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177435 VL - 2018 IS - 4323518 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Horas, Konstantin A1 - Holzapfel, Boris M. A1 - Gilbert, Fabian A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre F. T1 - Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty JF - BMC Musculoskeletal Disorders N2 - Background For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA). Methods We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses. Results On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching. Conclusion The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system. KW - total knee replacement KW - knee axis KW - patient-specific knee arthroplasty KW - knee osteoarthritis KW - implant positioning Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230012 VL - 21 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Gilbert, Fabian A1 - Blank, Marc A1 - Papazoglou, Jannis A1 - Rudert, Maximilian A1 - Nöth, Ulrich A1 - Steinert, Andre F. T1 - The Mayo conservative hip: complication analysis and management of the first 41 cases performed at a University level 1 department JF - BMC Muskoskeletal Disorders N2 - Background: To prevent bone loss in hip arthroplasty, several short stem systems have been developed, including the Mayo conservative hip system. While there is a plethora of data confirming inherent advantages of these systems, only little is known about potential complications, especially when surgeons start to use these systems. Methods: In this study, we present a retrospective analysis of the patients’ outcome, complications and the complication management of the first 41 Mayo conservative hips performed in 37 patients. For this reason, functional scores, radiographic analyses, peri- and postoperative complications were assessed at an average follow-up of 35 months. Results: The overall HHS improved from 61.2 pre-operatively to 85.6 post-operatively. The German Extra Short Musculoskeletal Function Assessment Questionnaire (XSFMA-D) improved from 30.3 pre-operatively to 12.2 post-operatively. The most common complication was an intraoperative non-displaced fracture of the proximal femur observed in 5 cases (12.1%). Diabetes, higher BMI and older ages were shown to be risk factors for these intra-operative periprosthetic fractures (p < 0.01). Radiographic analysis revealed a good offset reconstruction in all cases. Conclusion: In our series, a high complication rate with 12.1% of non-displaced proximal femoral fractures was observed using the Mayo conservative hip. This may be attributed to the flat learning curve of the system or the inherent patient characteristics of the presented cohort." KW - total hip arthroplasty KW - short hip stem KW - mayo stem KW - minimal invasive surgery Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-157812 VL - 18 IS - 250 ER -