TY - JOUR A1 - Werner, Rudolf A1 - Solnes, Lilja A1 - Javadi, Mehrbod A1 - Weich, Alexander A1 - Gorin, Michael A1 - Pienta, Kenneth A1 - Higuchi, Takahiro A1 - Buck, Andreas A1 - Pomper, Martin A1 - Rowe, Steven A1 - Lapa, Constantin T1 - SSTR-RADS Version 1.0 as a Reporting System for SSTR-PET Imaging and Selection of Potential PRRT Candidates: A Proposed Standardization Framework JF - Journal of Nuclear Medicine N2 - Reliable standards and criteria for somatostatin receptor (SSTR) positron emission tomography (PET) are still lacking. We herein propose a structured reporting system on a 5-point scale for SSTR-PET imaging, titled SSTR-RADS version 1.0, which might serve as a standardized assessment for both diagnosis and treatment planning in neuroendocrine tumors (NET). SSTR-RADS could guide the imaging specialist in interpreting SSTR-PET scans, facilitate communication with the referring clinician so that appropriate work-up for equivocal findings is pursued, and serve as a reliable tool for patient selection for planned Peptide Receptor Radionuclide Therapy. KW - Radionuclide Therapy KW - Standardisierung KW - Positronen-Emissions-Tomografie KW - 68Ga-DOTATATE/-TOC KW - Gastrointestinal KW - Neuroendocrine KW - Neuroendocrine Tumor KW - Oncology KW - GI KW - PET KW - PET/CT KW - PRRT KW - RADS KW - SSTR Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-161298 SN - 0161-5505 N1 - This research was originally published in JNM. Rudolf A. Werner, Lilja B. Solnes, Mehrbod Som Javadi, Alexander Weich, Michael A. Gorin, Kenneth J. Pienta, Takahiro Higuchi, Andreas K. Buck, Martin G. Pomper, Steven P. Rowe, Constantin Lapa. SSTR-RADS Version 1.0 as a Reporting System for SSTR-PET Imaging and Selection of Potential PRRT Candidates: A Proposed Standardization Framework. J. Nucl. Med. July 1, 2018, vol. 59, no. 7, 1085-1091. © SNMMI ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Weich, Alexander A1 - Kircher, Malte A1 - Solnes, Lilja B. A1 - Javadi, Mehrbod S. A1 - Higuchi, Takahiro A1 - Buck, Andreas K. A1 - Pomper, Martin G. A1 - Rowe, Steven A1 - Lapa, Constantin T1 - The theranostic promise for neuroendocrine tumors in the late 2010s – Where do we stand, where do we go? JF - Theranostics N2 - More than 25 years after the first peptide receptor radionuclide therapy (PRRT), the concept of somatostatin receptor (SSTR)-directed imaging and therapy for neuroendocrine tumors (NET) is seeing rapidly increasing use. To maximize the full potential of its theranostic promise, efforts in recent years have expanded recommendations in current guidelines and included the evaluation of novel theranostic radiotracers for imaging and treatment of NET. Moreover, the introduction of standardized reporting framework systems may harmonize PET reading, address pitfalls in interpreting SSTR-PET/CT scans and guide the treating physician in selecting PRRT candidates. Notably, the concept of PRRT has also been applied beyond oncology, e.g. for treatment of inflammatory conditions like sarcoidosis. Future perspectives may include the efficacy evaluation of PRRT compared to other common treatment options for NET, novel strategies for closer monitoring of potential side effects, the introduction of novel radiotracers with beneficial pharmacodynamic and kinetic properties or the use of supervised machine learning approaches for outcome prediction. This article reviews how the SSTR-directed theranostic concept is currently applied and also reflects on recent developments that hold promise for the future of theranostics in this context. KW - theranostics KW - Positronen-Emissions-Tomografie KW - PRRT KW - somatostatin receptor KW - peptide receptor radionuclide therapy KW - neuroendocrine tumor Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-170264 VL - 8 IS - 22 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Weich, Alexander A1 - Higuchi, Takahiro A1 - Schmid, Jan S. A1 - Schirbel, Andreas A1 - Lassmann, Michael A1 - Wild, Vanessa A1 - Rudelius, Martina A1 - Kudlich, Theodor A1 - Herrmann, Ken A1 - Scheurlen, Michael A1 - Buck, Andreas K. A1 - Kropf, Saskia A1 - Wester, Hans-Jürgen A1 - Lapa, Constantin T1 - Imaging of Chemokine Receptor 4 Expression in Neuroendocrine Tumors - a Triple Tracer Comparative Approach JF - Theranostics N2 - C-X-C motif chemokine receptor 4 (CXCR4) and somatostatin receptors (SSTR) are overexpressed in gastro-entero-pancreatic neuroendocrine tumors (GEP-NET). In this study, we aimed to elucidate the feasibility of non-invasive CXCR4 positron emission tomography/computed tomography (PET/CT) imaging in GEP-NET patients using [\(^{68}\)Ga]Pentixafor in comparison to \(^{68}\)Ga-DOTA-D-Phe-Tyr3-octreotide ([\(^{68}\)Ga]DOTATOC) and \(^{18}\)F-fluorodeoxyglucose ([\(^{18}\)F]FDG). Twelve patients with histologically proven GEP-NET (3xG1, 4xG2, 5xG3) underwent [\(^{68}\)Ga]DOTATOC, [\(^{18}\)F]FDG, and [\(^{68}\)Ga]Pentixafor PET/CT for staging and planning of the therapeutic management. Scans were analyzed on a patient as well as on a lesion basis and compared to immunohistochemical staining patterns of CXCR4 and somatostatin receptors SSTR2a and SSTR5. [\(^{68}\)Ga]Pentixafor visualized tumor lesions in 6/12 subjects, whereas [\(^{18}\)F]FDG revealed sites of disease in 10/12 and [\(^{68}\)Ga]DOTATOC in 11/12 patients, respectively. Regarding sensitivity, SSTR-directed PET was the superior imaging modality in all G1 and G2 NET. CXCR4-directed PET was negative in all G1 NET. In contrast, 50% of G2 and 80% of G3 patients exhibited [\(^{68}\)Ga]Pentixafor-positive tumor lesions. Whereas CXCR4 seems to play only a limited role in detecting well-differentiated NET, increasing receptor expression could be non-invasively observed with increasing tumor grade. Thus, [\(^{68}\)Ga]Pentixafor PET/CT might serve as non-invasive read-out for evaluating the possibility of CXCR4-directed endoradiotherapy in advanced dedifferentiated SSTR-negative tumors. KW - SSTR KW - peptide receptor radionuclide therapy KW - neuroendocrine tumor KW - [\(^{68}\)Ga]Pentixafor KW - CXCR4 KW - chemokine receptor KW - PET/CT KW - DOTATOC KW - PRRT KW - Positronen-Emissions-Tomografie Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158008 VL - 7 IS - 6 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Bundschuh, Ralph A. A1 - Bundschuh, Lena A1 - Javadi, Mehrbod S. A1 - Higuchi, Takahiro A1 - Weich, Alexander A1 - Sheikhbahaei, Sara A1 - Pienta, Kenneth J. A1 - Buck, Andreas K. A1 - Pomper, Martin G. A1 - Gorin, Michael A. A1 - Lapa, Constantin A1 - Rowe, Steven P. T1 - MI-RADS: Molecular Imaging Reporting and Data Systems – A Generalizable Framework for Targeted Radiotracers with Theranostic Implications JF - Annals of Nuclear Medicine N2 - Both prostate-specific membrane antigen (PSMA)- and somatostatin receptor (SSTR)-targeted positron emission tomography (PET) imaging agents for staging and restaging of prostate carcinoma or neuroendocrine tumors, respectively, are seeing rapidly expanding use. In addition to diagnostic applications, both classes of radiotracers can be used to triage patients for theranostic endoradiotherapy. While interpreting PSMA- or SSTR-targeted PET/computed tomography (CT) scans, the reader has to be aware of certain pitfalls. Adding to the complexity of the interpretation of those imaging agents, both normal biodistribution, and also false-positive and -negative findings differ between PSMA- and SSTR-targeted PET radiotracers. Herein summarized under the umbrella term molecular imaging reporting and data systems (MI-RADS), two novel RADS classifications for PSMA- and SSTR-targeted PET imaging are described (PSMA- and SSTR-RADS). Both framework systems may contribute to increase the level of a reader’s confidence and to navigate the imaging interpreter through indeterminate lesions, so that appropriate workup for equivocal findings can be pursued. Notably, PSMA- and SSTR-RADS are structured in a reciprocal fashion, i.e. if the reader is familiar with one system, the other system can readily be applied as well. In the present review we will discuss the most common pitfalls on PSMA- and SSTR-targeted PET/CT, briefly introduce PSMA- and SSTR-RADS, and define a future role of the umbrella framework MI-RADS compared to other harmonization systems. KW - PET KW - Positronen-Emissions-Tomografie KW - prostate cancer KW - neuroendocrine tumor KW - prostate-specific membrane antigen (PSMA) KW - somatostatin receptor (SSTR) KW - positron emission tomography KW - theranostics KW - standardization KW - RADS KW - reporting and data systems KW - personalized medicine Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-166995 SN - 0914-7187 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Beykan, Seval A1 - Higuchi, Takahiro A1 - Lückerath, Katharina A1 - Weich, Alexander A1 - Scheurlen, Michael A1 - Bluemel, Christina A1 - Herrmann, Ken A1 - Buck, Andreas K. A1 - Lassmann, Michael A1 - Lapa, Constantin A1 - Hänscheid, Heribert T1 - The impact of \(^{177}\)Lu-octreotide therapy on \(^{99m}\)Tc-MAG3 clearance is not predictive for late nephropathy JF - Oncotarget N2 - Peptide Receptor Radionuclide Therapy (PRRT) for the treatment of neuroendocrine tumors may lead to kidney deterioration. This study aimed to evaluate the suitability of \(^{99m}\)Tc-mercaptoacetyltriglycine (\(^{99m}\)Tc-MAG3) clearance for the early detection of PRRT-induced changes on tubular extraction (TE). TE rate (TER) was measured prior to 128 PRRT cycles (7.6±0.4 GBq \(^{177}\)Lu-octreotate/octreotide each) in 32 patients. TER reduction during PRRT was corrected for age-related decrease and analyzed for the potential to predict loss of glomerular filtration (GF). The GF rate (GFR) as measure for renal function was derived from serum creatinine. The mean TER was 234 ± 53 ml/min/1.73 m² before PRRT (baseline) and 221 ± 45 ml/min/1.73 m² after a median follow-up of 370 days. The age-corrected decrease (mean: -3%, range: -27% to +19%) did not reach significance (p=0.09) but significantly correlated with the baseline TER (Spearman p=-0.62, p<0.001). Patients with low baseline TER showed an improved TER after PRRT, high decreases were only observed in individuals with high baseline TER. Pre-therapeutic TER data were inferior to plasma creatinine-derived GFR estimates in predicting late nephropathy. TER assessed by \(^{99m}\)Tc-MAG3­clearance prior to and during PRRT is not suitable as early predictor of renal injury and an increased risk for late nephropathy. KW - renal scintigraphy KW - neuroendocrine tumor KW - 177Lu KW - MAG3 KW - PRRT Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177318 VL - 7 IS - 27 ER - TY - JOUR A1 - Weich, Alexander A1 - Werner, Rudolf A. A1 - Buck, Andreas K. A1 - Hartrampf, Philipp E. A1 - Serfling, Sebastian E. A1 - Scheurlen, Michael A1 - Wester, Hans-Jürgen A1 - Meining, Alexander A1 - Kircher, Stefan A1 - Higuchi, Takahiro A1 - Pomper, Martin G. A1 - Rowe, Steven P. A1 - Lapa, Constantin A1 - Kircher, Malte T1 - CXCR4-Directed PET/CT in Patients with Newly Diagnosed Neuroendocrine Carcinomas JF - Diagnostics N2 - We aimed to elucidate the diagnostic potential of the C-X-C motif chemokine receptor 4 (CXCR4)-directed positron emission tomography (PET) tracer \(^{68}\)Ga-Pentixafor in patients with poorly differentiated neuroendocrine carcinomas (NEC), relative to the established reference standard \(^{18}\)F-FDG PET/computed tomography (CT). In our database, we retrospectively identified 11 treatment-naïve patients with histologically proven NEC, who underwent \(^{18}\)F-FDG and CXCR4-directed PET/CT for staging and therapy planning. The images were analyzed on a per-patient and per-lesion basis and compared to immunohistochemical staining (IHC) of CXCR4 from PET-guided biopsies. \(^{68}\)Ga-Pentixafor visualized tumor lesions in 10/11 subjects, while \(^{18}\)F-FDG revealed sites of disease in all 11 patients. Although weak to moderate CXCR4 expression could be corroborated by IHC in 10/11 cases, \(^{18}\)F-FDG PET/CT detected significantly more tumor lesions (102 vs. 42; total lesions, n = 107; p < 0.001). Semi-quantitative analysis revealed markedly higher 18F-FDG uptake as compared to \(^{68}\)Ga-Pentixafor (maximum and mean standardized uptake values (SUV) and tumor-to-background ratios (TBR) of cancerous lesions, SUVmax: 12.8 ± 9.8 vs. 5.2 ± 3.7; SUVmean: 7.4 ± 5.4 vs. 3.1 ± 3.2, p < 0.001; and, TBR 7.2 ± 7.9 vs. 3.4 ± 3.0, p < 0.001). Non-invasive imaging of CXCR4 expression in NEC is inferior to the reference standard \(^{18}\)F-FDG PET/CT. KW - CXCR4 KW - NET KW - NEC KW - 68Ga-Pentixafor KW - 18F-FDG Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-234231 SN - 2075-4418 VL - 11 IS - 4 ER - TY - JOUR A1 - Weich, Alexander A1 - Rogoll, Dorothee A1 - Gawlas, Sophia A1 - Mayer, Lars A1 - Weich, Wolfgang A1 - Pongracz, Judit A1 - Kudlich, Theodor A1 - Meining, Alexander A1 - Scheurlen, Michael T1 - Wnt/β-catenin signaling regulates CXCR4 expression and [\(^{68}\)Ga] Pentixafor internalization in neuroendocrine tumor cells JF - Diagnostics N2 - Loss of Somatostatin Receptor 2 (SSTR2) expression and rising CXC Chemokine Receptor Type 4 (CXCR4) expression are associated with dedifferentiation in neuroendocrine tumors (NET). In NET, CXCR4 expression is associated with enhanced metastatic and invasive potential and worse prognosis but might be a theragnostic target. Likewise, activation of Wnt/β-catenin signaling may promote a more aggressive phenotype in NET. We hypothesized an interaction of the Wnt/β-catenin pathway with CXCR4 expression and function in NET. The NET cell lines BON-1, QGP-1, and MS-18 were exposed to Wnt inhibitors (5-aza-CdR, quercetin, and niclosamide) or the Wnt activator LiCl. The expressions of Wnt pathway genes and of CXCR4 were studied by qRT-PCR, Western blot, and immunohistochemistry. The effects of Wnt modulators on uptake of the CXCR4 ligand [\(^{68}\)Ga] Pentixafor were measured. The Wnt activator LiCl induced upregulation of CXCR4 and Wnt target gene expression. Treatment with the Wnt inhibitors had opposite effects. LiCl significantly increased [\(^{68}\)Ga] Pentixafor uptake, while treatment with Wnt inhibitors decreased radiopeptide uptake. Wnt pathway modulation influences CXCR4 expression and function in NET cell lines. Wnt modulation might be a tool to enhance the efficacy of CXCR4-directed therapies in NET or to inhibit CXCR4-dependent proliferative signaling. The underlying mechanisms for the interaction of the Wnt pathway with CXCR4 expression and function have yet to be clarified. KW - neuroendocrine tumor KW - NET KW - Wnt KW - β-catenin KW - CXCR4 KW - [\(^{68}\)Ga] Pentixafor KW - BON-1 KW - QGP-1 KW - MS-18 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-228914 SN - 2075-4418 VL - 11 IS - 2 ER - TY - JOUR A1 - Weich, Alexander A1 - Higuchi, Takahiro A1 - Bundschuh, Ralph A. A1 - Lapa, Constantin A1 - Serfling, Sebastian E. A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Herrmann, Ken A1 - Buck, Andreas K. A1 - Derlin, Thorsten A1 - Werner, Rudolf A. T1 - Training on reporting and data system (RADS) for somatostatin-receptor targeted molecular imaging can reduce the test anxiety of inexperienced readers JF - Molecular Imaging and Biology N2 - Purpose For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader’s anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader’s confidence, and its implementation in clinical routine. Procedures A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader’s confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen’s d was calculated (small, d = 0.20; large effect, d = 0.80). Results Of 22 participants, Pre and Post were returned by 21/22 (95.5%). In total, 14/21 (66.7%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d =  − 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader’s confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21). Conclusions A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results. KW - PET/CT KW - neuroendocrine tumor KW - PRRT KW - peptide receptor radionuclide therapy KW - reporting and data system KW - SSTR-RADS KW - RADS Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324645 VL - 24 IS - 4 ER - TY - JOUR A1 - Serfling, Sebastian E. A1 - Lapa, Constantin A1 - Dreher, Niklas A1 - Hartrampf, Philipp E. A1 - Rowe, Steven P. A1 - Higuchi, Takahiro A1 - Schirbel, Andreas A1 - Weich, Alexander A1 - Hahner, Stefanie A1 - Fassnacht, Martin A1 - Buck, Andreas K. A1 - Werner, Rudolf A. T1 - Impact of tumor burden on normal organ distribution in patients imaged with CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT JF - Molecular Imaging and Biology N2 - Background CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs. Methods Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden. Results Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found. Conclusions In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged. KW - CXCR4 KW - C-X-C motif chemokine receptor 4 KW - PET KW - [68Ga]PentixaFor KW - [177Lu]/[90Y]PentixaTher KW - theranostics KW - endoradiotherapy Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324622 VL - 24 IS - 4 ER - TY - JOUR A1 - Reimer, Stanislaus A1 - Seyfried, Florian A1 - Flemming, Sven A1 - Brand, Markus A1 - Weich, Alexander A1 - Widder, Anna A1 - Plaßmeier, Lars A1 - Kraus, Peter A1 - Döring, Anna A1 - Hering, Ilona A1 - Hankir, Mohammed K. A1 - Meining, Alexander A1 - Germer, Christoph-Thomas A1 - Lock, Johan F. A1 - Groneberg, Kaja T1 - Evolution of endoscopic vacuum therapy for upper gastrointestinal leakage over a 10-year period: a quality improvement study JF - Surgical Endoscopy N2 - Background Endoscopic vacuum therapy (EVT) is an effective treatment option for leakage of the upper gastrointestinal (UGI) tract. The aim of this study was to evaluate the clinical impact of quality improvements in EVT management on patients’ outcome. Methods All patients treated by EVT at our center during 2012–2021 were divided into two consecutive and equal-sized cohorts (period 1 vs. period 2). Over time several quality improvement strategies were implemented including the earlier diagnosis and EVT treatment and technical optimization of endoscopy. The primary endpoint was defined as the composite score MTL30 (mortality, transfer, length-of-stay > 30 days). Secondary endpoints included EVT efficacy, complications, in-hospital mortality, length-of-stay (LOS) and nutrition status at discharge. Results A total of 156 patients were analyzed. During the latter period the primary endpoint MTL30 decreased from 60.8 to 39.0% (P = .006). EVT efficacy increased from 80 to 91% (P = .049). Further, the need for additional procedures for leakage management decreased from 49.9 to 29.9% (P = .013) and reoperations became less frequent (38.0% vs.15.6%; P = .001). The duration of leakage therapy and LOS were shortened from 25 to 14 days (P = .003) and 38 days to 25 days (P = .006), respectively. Morbidity (as determined by the comprehensive complication index) decreased from 54.6 to 46.5 (P = .034). More patients could be discharged on oral nutrition (70.9% vs. 84.4%, P = .043). Conclusions Our experience confirms the efficacy of EVT for the successful management of UGI leakage. Our quality improvement analysis demonstrates significant changes in EVT management resulting in accelerated recovery, fewer complications and improved functional outcome. KW - anastomotic leak KW - gastrointestinal perforation KW - esophageal perforation KW - endoluminal KW - vacuum-assisted closure KW - negative pressure Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-323953 VL - 36 IS - 12 ER -