TY - JOUR A1 - Maniuc, Octavian A1 - Salinger, Tim A1 - Anders, Fabian A1 - Müntze, Jonas A1 - Liu, Dan A1 - Hu, Kai A1 - Ertl, Georg A1 - Frantz, Stefan A1 - Nordbeck, Peter T1 - Impella CP use in patients with non‐ischaemic cardiogenic shock JF - ESC Heart Failure N2 - Aims From the various mechanical cardiac assist devices and indications available, the use of the percutaneous intraventricular Impella CP pump is usually restricted to acute ischaemic shock or prophylactic indications in high‐risk interventions. In the present study, we investigated clinical usefulness of the Impella CP device in patients with non‐ischaemic cardiogenic shock as compared with acute ischaemia. Methods and results In this retrospective single‐centre analysis, patients who received an Impella CP at the University Hospital Würzburg between 2013 and 2017 due to non‐ischaemic cardiogenic shock were age‐matched 2:1 with patients receiving the device due to ischaemic cardiogenic shock. Inclusion criteria were therapy refractory haemodynamic instability with severe left ventricular systolic dysfunction and serum lactate >2.0 mmol/L at implantation. Basic clinical data, indications for mechanical ventricular support, and outcome were obtained in all patients with non‐ischaemic as well as ischaemic shock and compared between both groups. Continuous variables are expressed as mean ± standard deviation or median (quartiles). Categorical variables are presented as count and per cent. Twenty‐five patients had cardiogenic shock due to non‐ischaemic reasons and were compared with 50 patients with cardiogenic shock due to acute myocardial infarction. Resuscitation rates before implantation of Impella CP were high (32 vs. 42%; P = 0.402). At implantation, patients with non‐ischaemic cardiogenic shock had lower levels of high‐sensitive troponin T (110.65 [57.87–322.1] vs. 1610 [450.8–3861.5] pg/mL; P = 0.001) and lactate dehydrogenase (377 [279–608] vs. 616 [371.3–1109] U/L; P = 0.007), while age (59 ± 16 vs. 61.7 ± 11; P = 0.401), glomerular filtration rate (43.5 [33.2–59.7] vs. 48 [35.75–69] mL/min; P = 0.290), C‐reactive protein (5.17 [3.27–10.26] vs. 10.97 [3.23–17.2] mg/dL; P = 0.195), catecholamine index (30.6 [10.6–116.9] vs. 47.6 [11.7–90] μg/kg/min; P = 0.663), and serum lactate (2.6 [2.2–5.8] vs. 2.9 [1.3–6.6] mmol/L; P = 0.424) were comparable between both groups. There was a trend for longer duration of Impella support in the non‐ischaemic groups (5 [2–7.5] vs. 3 [2–5.25] days, P = 0.211). Rates of haemodialysis (52 vs. 47%; P = 0.680) and transition to extracorporeal membrane oxygenation (13.6 vs. 22.2%; P = 0.521) were comparable. No significant difference was found regarding both 30 day survival (48 vs. 30%; P = 0.126) and in‐hospital mortality (66.7 vs. 74%; P = 0.512), although there was a trend for better survival in the non‐ischaemic group. Conclusions These data suggest that temporary use of the Impella CP device might be a useful therapeutic option for bridge to recovery not only in ischaemic but also in non‐ischaemic cardiogenic shock. KW - Impella KW - Non‐ischaemic cardiogenic shock Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-202794 VL - 6 IS - 4 ER - TY - JOUR A1 - Heidenreich, Julius F. A1 - Weng, Andreas M. A1 - Donhauser, Julian A1 - Greiser, Andreas A1 - Chow, Kelvin A1 - Nordbeck, Peter A1 - Bley, Thorsten A. A1 - Köstler, Herbert T1 - T1- and ECV-mapping in clinical routine at 3 T: differences between MOLLI, ShMOLLI and SASHA JF - BMC Medical Imaging N2 - Background T1 mapping sequences such as MOLLI, ShMOLLI and SASHA make use of different technical approaches, bearing strengths and weaknesses. It is well known that obtained T1 relaxation times differ between the sequence techniques as well as between different hardware. Yet, T1 quantification is a promising tool for myocardial tissue characterization, disregarding the absence of established reference values. The purpose of this study was to evaluate the feasibility of native and post-contrast T1 mapping methods as well as ECV maps and its diagnostic benefits in a clinical environment when scanning patients with various cardiac diseases at 3 T. Methods Native and post-contrast T1 mapping data acquired on a 3 T full-body scanner using the three pulse sequences 5(3)3 MOLLI, ShMOLLI and SASHA in 19 patients with clinical indication for contrast enhanced MRI were compared. We analyzed global and segmental T1 relaxation times as well as respective extracellular volumes and compared the emerged differences between the used pulse sequences. Results T1 times acquired with MOLLI and ShMOLLI exhibited systematic T1 deviation compared to SASHA. Myocardial MOLLI T1 times were 19% lower and ShMOLLI T1 times 25% lower compared to SASHA. Native blood T1 times from MOLLI were 13% lower than SASHA, while post-contrast MOLLI T1-times were only 5% lower. ECV values exhibited comparably biased estimation with MOLLI and ShMOLLI compared to SASHA in good agreement with results reported in literature. Pathology-suspect segments were clearly differentiated from remote myocardium with all three sequences. Conclusion Myocardial T1 mapping yields systematically biased pre- and post-contrast T1 times depending on the applied pulse sequence. Additionally calculating ECV attenuates this bias, making MOLLI, ShMOLLI and SASHA better comparable. Therefore, myocardial T1 mapping is a powerful clinical tool for classification of soft tissue abnormalities in spite of the absence of established reference values. KW - T1 mapping KW - MOLLI KW - ShMOLLI KW - SASHA KW - Extracellular volume KW - 3 T Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-201999 VL - 19 ER -