TY - JOUR A1 - Kamawal, Yama A1 - Steinert, Andre F A1 - Holzapfel, Boris M A1 - Rudert, Maximilian A1 - Barthel, Thomas T1 - Case report - calcification of the medial collateral ligament of the knee with simultaneous calcifying tendinitis of the rotator cuff JF - BMC Muscoskeletal Disorders N2 - Calcification of the medial collateral ligament (MCL) of the knee is a very rare disease. We report on a case of a patient with a calcifying lesion within the MCL and simultaneous calcifying tendinitis of the rotator cuff in both shoulders. Case presentation: Calcification of the MCL was diagnosed both via x-ray and magnetic resonance imaging (MRI) and was successfully treated surgically. Calcifying tendinitis of the rotator cuff was successfully treated applying conservative methods. Conclusion: This is the first case report of a patient suffering from both a calcifying lesion within the medial collateral ligament and calcifying tendinitis of the rotator cuff in both shoulders. Clinical symptoms, radio-morphological characteristics and macroscopic features were very similar and therefore it can be postulated that the underlying pathophysiology is the same in both diseases. Our experience suggests that magnetic resonance imaging and x-ray are invaluable tools for the diagnosis of this inflammatory calcifying disease of the ligament, and that surgical repair provides a good outcome if conservative treatment fails. It seems that calcification of the MCL is more likely to require surgery than calcifying tendinitis of the rotator cuff. However, the exact reason for this remains unclear to date. KW - case report KW - calcification KW - medical collateral ligament KW - knee rotator cuff KW - open surgical repair Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-147669 VL - 17 IS - 283 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Holzapfel, Boris Michael A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre Friedrich T1 - Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants JF - Archives of Medical Science N2 - Introduction The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. Material and methods In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. Results On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). Conclusions Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease. KW - implant fit KW - bi-compartmental knee arthoplasty KW - bi-compartmental KW - implant positioning KW - knee osteoarthritis KW - knee arthroplasty KW - patient-specific KW - knee alignment Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159668 VL - 14 IS - 6 ER - TY - THES A1 - Kamawal, Yama T1 - Retrospektive Datenauswertung von radiologischen Ergebnissen nach patientenspezifischer Kniegelenksendoprothetik – ConforMIS iTotal® CR, iDuo® und iUni® G2 T1 - Retrospective evaluation of radiographic results after knee arthroplasty using patient-specific instruments and implants - ConforMIS iTotal® CR, iDuo® und iUni® G2 N2 - Retrospektive prä- und postoperative radiologische Datenauswertung patientenspezifischer Kniegelenksendoprothetik – ConforMIS iTotal® CR, iDuo® und iUni® G2. Vergleich und Diskussion der Daten hinsichtlich mechanischer Beinachse, Patellahöhe und -ausrichtung und Komponentendimensionierung und -ausrichtung. N2 - We report and discuss the radiographic results (implant fit, frontal and sagittal plane alignment) of patients who were treated with a novel patient-specific knee resurfacing system (ConforMIS iTotal® CR, iDuo® und iUni® G2) using custom-made implants and instruments. KW - Endoprothetik KW - Mechanische Beinachse Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-183490 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Horas, Konstantin A1 - Holzapfel, Boris M. A1 - Gilbert, Fabian A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre F. T1 - Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty JF - BMC Musculoskeletal Disorders N2 - Background For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA). Methods We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses. Results On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching. Conclusion The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system. KW - total knee replacement KW - knee axis KW - patient-specific knee arthroplasty KW - knee osteoarthritis KW - implant positioning Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230012 VL - 21 ER - TY - JOUR A1 - Eidmann, Annette A1 - Kamawal, Yama A1 - Luedemann, Martin A1 - Raab, Peter A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Demographics and etiology for lower extremity amputations — experiences of an university orthopaedic center in Germany JF - Medicina N2 - Background and Objectives: Currently, the worldwide incidence of major amputations in the general population is decreasing whereas the incidence of minor amputations is increasing. The purpose of our study was to analyze whether this trend is reflected among orthopaedic patients treated with lower extremity amputation in our orthopaedic university institution. Materials and Methods: We conducted a single-center retrospective study and included patients referred to our orthopaedic department for lower extremity amputation (LEA) between January 2007 and December 2019. Acquired data were the year of amputation, age, sex, level of amputation and cause of amputation. T test and Chi² test were performed to compare age and amputation rates between males and females; significance was defined as p < 0.05. Linear regression and multivariate logistic regression models were used to test time trends and to calculate probabilities for LEA. Results: A total of 114 amputations of the lower extremity were performed, of which 60.5% were major amputations. The number of major amputations increased over time with a rate of 0.6 amputation/year. Men were significantly more often affected by LEA than women. Age of LEA for men was significantly below the age of LEA for women (men: 54.8 ± 2.8 years, women: 64.9 ± 3.2 years, p = 0.021). Main causes leading to LEA were tumors (28.9%) and implant-associated complications (25.4%). Implant-associated complications and age raised the probability for major amputation, whereas malformation, angiopathies and infections were more likely to cause a minor amputation. Conclusions: Among patients in our orthopaedic institution, etiology of amputations of the lower extremity is multifactorial and differs from other surgical specialties. The number of major amputations has increased continuously over the past years. Age and sex, as well as diagnosis, influence the type and level of amputation. KW - lower extremity amputation KW - major amputation KW - minor amputation KW - orthopaedic surgery Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-304856 SN - 1648-9144 VL - 59 IS - 2 ER -