TY - JOUR A1 - Dorsch, Oliver A1 - Krieter, Detlef H. A1 - Lemke, Horst-Dieter A1 - Fischer, Stefan A1 - Melzer, Nima A1 - Sieder, Christian A1 - Bramlage, Peter A1 - Harenberg, Job T1 - A multi-center, prospective, open-label, 8-week study of certoparin for anticoagulation during maintenance hemodialysis – the membrane study JF - BMC Nephrology N2 - Background Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting. Methods Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary. Results 120 patients were screened, 109 enrolled (median age 71; range 26–90 years) and 106 available for efficacy analyses. The percentage of unsatisfactory dialysis results at 8 weeks due to clotting or bleeding, was 1.9% (n = 2/106; 95% confidence interval [CI] 0.23–6.65%); no major bleeding. 1.9% had moderate/severe clotting in the lines/bubble catcher and 2.8% in the dialyser at week 8. 15.7 ± 14.3% of the dialysis filters’ visual surface area was showing redness. In subgroups of patients receiving median doses of 3000 ± 0, 3000 (2400–6000) and 4200 (3000–6600) IU, plasma aXa levels at baseline, 4 and 8 weeks were 0.24 [95%CI 0.21–0.27], 0.33 [0.27–0.40] and 0.38 [0.33–0.45] aXa IU/ml at 2 h. \(C_{48h}\) was 0.01 [0.01–0.02] aXa IU at all visits. At baseline and 4 weeks \(AUC_{0-48h}\) was 2.66 [2.19–3.24] and 3.66 [3.00–4.45] aXa IU*h/ml. In 3.0% of dialyses (n = 83/2724) prolonged fistula compression times were documented. Eight patients (7.34%) had at least one episode of minor bleeding. 4) 85.3% of patients had any adverse event, 9.2% were serious without suspected drug relation; and in 32 patients a drug-relation was suspected. Conclusions Certoparin appears effective and safe for anticoagulation in patients undergoing maintenance hemodialysis. KW - hemodialysis Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124052 VL - 13 IS - 50 ER - TY - JOUR A1 - Dorsch, Oliver A1 - Krieter, Detlef H. A1 - Lemke, Horst-Dieter A1 - Fischer, Stefan A1 - Melzer, Nima A1 - Sieder, Christian A1 - Bramlage, Peter A1 - Harenberg, Job T1 - A multi-center, prospective, open-label, 8-week study of certoparin for anticoagulation during maintenance hemodialysis - the membrane study JF - BMC Nephrology N2 - Background: Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting. Methods: Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary. Results: 120 patients were screened, 109 enrolled (median age 71; range 26-90 years) and 106 available for efficacy analyses. The percentage of unsatisfactory dialysis results at 8 weeks due to clotting or bleeding, was 1.9% (n = 2/106; 95% confidence interval [CI] 0.23-6.65%); no major bleeding. 1.9% had moderate/severe clotting in the lines/bubble catcher and 2.8% in the dialyser at week 8.15.7 +/- 14.3% of the dialysis filters' visual surface area was showing redness. In subgroups of patients receiving median doses of 3000 +/- 0, 3000 (2400-6000) and 4200 (3000-6600) IU, plasma aXa levels at baseline, 4 and 8 weeks were 0.24 [ 95% CI 0.21-0.27], 0.33 [0.27-0.40] and 0.38 [0.33-0.45] aXa IU/ml at 2 h. C-48h was 0.01 [0.01-0.02] aXa IU at all visits. At baseline and 4 weeks AUC(0-48h) was 2.66 [2.19-3.24] and 3.66 [3.00-4.45] aXa IU*h/ml. In 3.0% of dialyses (n = 83/2724) prolonged fistula compression times were documented. Eight patients (7.34%) had at least one episode of minor bleeding. 4) 85.3% of patients had any adverse event, 9.2% were serious without suspected drug relation; and in 32 patients a drug-relation was suspected. Conclusions: Certoparin appears effective and safe for anticoagulation in patients undergoing maintenance hemodialysis. KW - XA KW - low molecular weight KW - severe renal insufficiency KW - unfractionated heparin KW - standard heparin KW - enoxaparin KW - metaanalysis KW - coagulation KW - fragmin KW - sodium Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-134845 VL - 13 IS - 50 ER - TY - JOUR A1 - Devine, Eric A1 - Krieter, Detlef H. A1 - Rüth, Marieke A1 - Jankovski, Joachim A1 - Lemke, Horst-Dieter T1 - Binding Affinity and Capacity for the Uremic Toxin Indoxyl Sulfate JF - Toxins N2 - Protein binding prevents uremic toxins from removal by conventional extracorporeal therapies leading to accumulation in maintenance dialysis patients. Weakening of the protein binding may enhance the dialytic elimination of these toxins. In ultrafiltration and equilibrium dialysis experiments, different measures to modify the plasma binding affinity and capacity were tested: (i), increasing the sodium chloride (NaCl) concentration to achieve a higher ionic strength; (ii), increasing the temperature; and (iii), dilution. The effects on the dissociation constant K-D and the protein bound fraction of the prototypical uremic toxin indoxyl sulfate (IS) in plasma of healthy and uremic individuals were studied. Binding of IS corresponded to one site binding in normal plasma. K-D increased linearly with the NaCl concentration between 0.15 (K-D = 13.2 +/- 3.7 mu M) and 0.75 M (K-D = 56.2 +/- 2.0 mu M). Plasma dilution further reduced the protein bound toxin fraction by lowering the protein binding capacity of the plasma. Higher temperatures also decreased the protein bound fraction of IS in human plasma. Increasing the NaCl concentration was effective to weaken the binding of IS also in uremic plasma: the protein bound fraction decreased from 89% +/- 3% to 81% +/- 3% at 0.15 and 0.75 M NaCl, respectively. Dilution and increasing the ionic strength and temperature enhance the free fraction of IS allowing better removal of the substance during dialysis. Applied during clinical dialysis, this may have beneficial effects on the long-term outcome of maintenance dialysis patients. KW - protein binding KW - hemodialysis KW - human serum albumin KW - dialyzer membrane KW - P-cresyl sulfate KW - removal KW - dialysate KW - progression KW - clearance KW - kidney disease; KW - protein-bound solutes KW - chronic kidney-disease KW - ionic strength KW - uremic toxin Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-117486 VL - 6 IS - 2 ER - TY - JOUR A1 - Krieter, Detlef H. A1 - Kerwagen, Simon A1 - Rüth, Marieke A1 - Lemke, Horst-Dieter A1 - Wanner, Christoph T1 - Differences in dialysis efficacy have limited effects on protein-bound uremic toxins plasma levels over time JF - Toxins N2 - The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied. The present prospective, randomized, cross-over trial tested dialysis efficacy and monitored pre-treatment pCS and IS concentrations in 15 patients on low-flux and high-flux hemodialysis and high-convective volume postdilution hemodiafiltration over six weeks each. Although hemodiafiltration achieved by far the highest toxin removal, only the mean total IS level was decreased at week three (16.6 ± 12.1 mg/L) compared to baseline (18.9 ± 13.0 mg/L, p = 0.027) and to low-flux dialysis (20.0 ± 12.7 mg/L, p = 0.021). At week six, the total IS concentration in hemodiafiltration reached the initial values again. Concentrations of free IS and free and total pCS remained unaltered. Highest beta2-microglobulin elimination in hemodiafiltration (p < 0.001) led to a persistent decrease of the plasma levels at week three and six (each p < 0.001). In contrast, absent removal in low-flux dialysis resulted in rising beta2-microglobulin concentrations (p < 0.001). In conclusion, this trial demonstrated that even large differences in instantaneous protein-bound toxin removal by current extracorporeal dialysis techniques may have only limited impact on IS and pCS plasma levels in the longer term. KW - protein-bound uremic toxins KW - end-stage renal disease KW - hemodialysis KW - hemodiafiltration KW - dialysis adequacy Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-201770 VL - 11 IS - 4 ER - TY - JOUR A1 - Krieter, Detlef H. A1 - Jeyaseelan, Jarline A1 - Rüth, Marieke A1 - Lemke, Horst-Dieter A1 - Wanner, Christoph A1 - Drechsler, Christiane T1 - Clinical hemocompatibility of double-filtration lipoprotein apheresis comparing polyethersulfone and ethylene-vinyl alcohol copolymer membranes JF - Artificial Organs N2 - Activation of the complement system and leukocytes by blood–membrane interactions may further promote arteriosclerosis typically present in patients on lipoprotein apheresis. As clinical data on the hemocompatibility of lipoprotein apheresis are scarce, a controlled clinical study comparing two different types of plasma separation and fractionation membranes used in double-filtration lipoprotein apheresis was urgently needed, as its outcome may influence clinical decision-making. In a prospective, randomized, crossover controlled trial, eight patients on double-filtration lipoprotein apheresis were subjected to one treatment with recent polyethersulfone (PES) plasma separation and fractionation membranes and one control treatment using a set of ethylene-vinyl alcohol copolymer (EVAL) membranes. White blood cell (WBC) and platelet (PC) counts, complement factor C5a and thrombin–antithrombin III (TAT) concentrations were determined in samples drawn at defined times from different sites of the extracorporeal blood and plasma circuit. With a nadir at 25 minutes, WBCs in EVAL decreased to 33.5 ± 10.7% of baseline compared with 63.8 ± 22.0% at 20 minutes in PES (P < .001). The maximum C5a levels in venous blood reentering the patients were measured at 30 minutes, being 30.0 ± 11.2 µg/L with EVAL and 12.3 ± 9.0 µg/L with PES (P < .05). The highest C5a concentrations were found in plasma after the plasma filters (EVAL 56.1 ± 22.0 µg/L at 15 minutes vs PES 23.3 ± 15.2 µg/L at 10 minutes; P < .001). PC did not significantly decrease over time with both membrane types, whereas TAT levels did not rise until the end of the treatment without differences between membranes. Regarding lipoprotein(a) and low-density lipoprotein (LDL) cholesterol removal, both membrane sets performed equally. Compared with EVAL, PES membranes cause less leukocyte and complement system activation, the classical parameters of hemocompatibility of extracorporeal treatment procedures, at identical treatment efficacy. Better hemocompatibility may avoid inflammation-promoting effects through blood–material interactions in patients requiring double-filtration lipoprotein apheresis. KW - lipoprotein(a) KW - biocompatibility KW - fractionation membranev KW - hypercholesterolemia KW - LDL cholesterol KW - lipoprotein apheresis Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-258307 VL - 45 IS - 9 ER - TY - JOUR A1 - Krieter, Detlef H. A1 - Rüth, Marieke A1 - Lemke, Horst-Dieter A1 - Wanner, Christoph T1 - Clinical performance comparison of two medium cut-off dialyzers JF - Therapeutic Apheresis and Dialysis N2 - Introduction Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis. Methods In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified. Results ELISIO-HX achieved slightly lower reduction ratios for β2-microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2%/g; p = 0.006) to ELISIO-HX. Conclusions The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis. KW - dialysis adequacy KW - medium cut-off dialyzer KW - hemodialysis KW - free light chains KW - end-stage kidney disease Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-318643 VL - 27 IS - 2 SP - 284 EP - 292 ER -