TY - JOUR A1 - Sperlich, Billy A1 - Düking, Peter A1 - Leppich, Robert A1 - Holmberg, Hans-Christer T1 - Strengths, weaknesses, opportunities, and threats associated with the application of artificial intelligence in connection with sport research, coaching, and optimization of athletic performance: a brief SWOT analysis JF - Frontiers in Sports and Active Living N2 - Here, we performed a non-systematic analysis of the strength, weaknesses, opportunities, and threats (SWOT) associated with the application of artificial intelligence to sports research, coaching and optimization of athletic performance. The strength of AI with regards to applied sports research, coaching and athletic performance involve the automation of time-consuming tasks, processing and analysis of large amounts of data, and recognition of complex patterns and relationships. However, it is also essential to be aware of the weaknesses associated with the integration of AI into this field. For instance, it is imperative that the data employed to train the AI system be both diverse and complete, in addition to as unbiased as possible with respect to factors such as the gender, level of performance, and experience of an athlete. Other challenges include e.g., limited adaptability to novel situations and the cost and other resources required. Opportunities include the possibility to monitor athletes both long-term and in real-time, the potential discovery of novel indicators of performance, and prediction of risk for future injury. Leveraging these opportunities can transform athletic development and the practice of sports science in general. Threats include over-dependence on technology, less involvement of human expertise, risks with respect to data privacy, breaching of the integrity and manipulation of data, and resistance to adopting such new technology. Understanding and addressing these SWOT factors is essential for maximizing the benefits of AI while mitigating its risks, thereby paving the way for its successful integration into sport science research, coaching, and optimization of athletic performance. KW - XAI and explainable artificial intelligence KW - XAI KW - elite sport KW - performance KW - exercise science KW - SWOT KW - artifical inteligence Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357973 VL - 5 ER - TY - JOUR A1 - Bayer, Daniel A1 - Pruckner, Marco T1 - A digital twin of a local energy system based on real smart meter data JF - Energy Informatics N2 - The steadily increasing usage of smart meters generates a valuable amount of high-resolution data about the individual energy consumption and production of local energy systems. Private households install more and more photovoltaic systems, battery storage and big consumers like heat pumps. Thus, our vision is to augment these collected smart meter time series of a complete system (e.g., a city, town or complex institutions like airports) with simulatively added previously named components. We, therefore, propose a novel digital twin of such an energy system based solely on a complete set of smart meter data including additional building data. Based on the additional geospatial data, the twin is intended to represent the addition of the abovementioned components as realistically as possible. Outputs of the twin can be used as a decision support for either system operators where to strengthen the system or for individual households where and how to install photovoltaic systems and batteries. Meanwhile, the first local energy system operators had such smart meter data of almost all residential consumers for several years. We acquire those of an exemplary operator and discuss a case study presenting some features of our digital twin and highlighting the value of the combination of smart meter and geospatial data. KW - digital twin KW - simulation KW - local energy system KW - decision support system KW - smart meter data utilization KW - future energy grid exploration Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357456 VL - 6 ER - TY - JOUR A1 - Krenzer, Adrian A1 - Heil, Stefan A1 - Fitting, Daniel A1 - Matti, Safa A1 - Zoller, Wolfram G. A1 - Hann, Alexander A1 - Puppe, Frank T1 - Automated classification of polyps using deep learning architectures and few-shot learning JF - BMC Medical Imaging N2 - Background Colorectal cancer is a leading cause of cancer-related deaths worldwide. The best method to prevent CRC is a colonoscopy. However, not all colon polyps have the risk of becoming cancerous. Therefore, polyps are classified using different classification systems. After the classification, further treatment and procedures are based on the classification of the polyp. Nevertheless, classification is not easy. Therefore, we suggest two novel automated classifications system assisting gastroenterologists in classifying polyps based on the NICE and Paris classification. Methods We build two classification systems. One is classifying polyps based on their shape (Paris). The other classifies polyps based on their texture and surface patterns (NICE). A two-step process for the Paris classification is introduced: First, detecting and cropping the polyp on the image, and secondly, classifying the polyp based on the cropped area with a transformer network. For the NICE classification, we design a few-shot learning algorithm based on the Deep Metric Learning approach. The algorithm creates an embedding space for polyps, which allows classification from a few examples to account for the data scarcity of NICE annotated images in our database. Results For the Paris classification, we achieve an accuracy of 89.35 %, surpassing all papers in the literature and establishing a new state-of-the-art and baseline accuracy for other publications on a public data set. For the NICE classification, we achieve a competitive accuracy of 81.13 % and demonstrate thereby the viability of the few-shot learning paradigm in polyp classification in data-scarce environments. Additionally, we show different ablations of the algorithms. Finally, we further elaborate on the explainability of the system by showing heat maps of the neural network explaining neural activations. Conclusion Overall we introduce two polyp classification systems to assist gastroenterologists. We achieve state-of-the-art performance in the Paris classification and demonstrate the viability of the few-shot learning paradigm in the NICE classification, addressing the prevalent data scarcity issues faced in medical machine learning. KW - machine learning KW - deep learning KW - endoscopy KW - gastroenterology KW - automation KW - image classification KW - transformer KW - deep metric learning KW - few-shot learning Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357465 VL - 23 ER - TY - JOUR A1 - Rack, Christian A1 - Fernando, Tamara A1 - Yalcin, Murat A1 - Hotho, Andreas A1 - Latoschik, Marc Erich T1 - Who is Alyx? A new behavioral biometric dataset for user identification in XR JF - Frontiers in Virtual Reality N2 - Introduction: This paper addresses the need for reliable user identification in Extended Reality (XR), focusing on the scarcity of public datasets in this area. Methods: We present a new dataset collected from 71 users who played the game “Half-Life: Alyx” on an HTC Vive Pro for 45 min across two separate sessions. The dataset includes motion and eye-tracking data, along with physiological data from a subset of 31 users. Benchmark performance is established using two state-of-the-art deep learning architectures, Convolutional Neural Networks (CNN) and Gated Recurrent Units (GRU). Results: The best model achieved a mean accuracy of 95% for user identification within 2 min when trained on the first session and tested on the second. Discussion: The dataset is freely available and serves as a resource for future research in XR user identification, thereby addressing a significant gap in the field. Its release aims to facilitate advancements in user identification methods and promote reproducibility in XR research. KW - dataset KW - behaviometric KW - deep learning KW - physiological dataset KW - user identification Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-353979 SN - 2673-4192 VL - 4 ER - TY - JOUR A1 - Helmer, Philipp A1 - Rodemers, Philipp A1 - Hottenrott, Sebastian A1 - Leppich, Robert A1 - Helwich, Maja A1 - Pryss, Rüdiger A1 - Kranke, Peter A1 - Meybohm, Patrick A1 - Winkler, Bernd E. A1 - Sammeth, Michael T1 - Evaluating blood oxygen saturation measurements by popular fitness trackers in postoperative patients: a prospective clinical trial JF - iScience N2 - Summary Blood oxygen saturation is an important clinical parameter, especially in postoperative hospitalized patients, monitored in clinical practice by arterial blood gas (ABG) and/or pulse oximetry that both are not suitable for a long-term continuous monitoring of patients during the entire hospital stay, or beyond. Technological advances developed recently for consumer-grade fitness trackers could—at least in theory—help to fill in this gap, but benchmarks on the applicability and accuracy of these technologies in hospitalized patients are currently lacking. We therefore conducted at the postanaesthesia care unit under controlled settings a prospective clinical trial with 201 patients, comparing in total >1,000 oxygen blood saturation measurements by fitness trackers of three brands with the ABG gold standard and with pulse oximetry. Our results suggest that, despite of an overall still tolerable measuring accuracy, comparatively high dropout rates severely limit the possibilities of employing fitness trackers, particularly during the immediate postoperative period of hospitalized patients. Highlights •The accuracy of O2 measurements by fitness trackers is tolerable (RMSE ≲4%) •Correlation with arterial blood gas measurements is fair to moderate (PCC = [0.46; 0.64]) •Dropout rates of fitness trackers during O2 monitoring are high (∼1/3 values missing) •Fitness trackers cannot be recommended for O2 measuring during critical monitoring KW - multidisciplinary KW - health sciences KW - clinical measurement in health technology KW - bioelectronics KW - fitness trackers Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-349913 SN - 2589-0042 VL - 26 IS - 11 ER - TY - JOUR A1 - Hossfeld, Tobias A1 - Heegaard, Poul E. A1 - Kellerer, Wolfgang T1 - Comparing the scalability of communication networks and systems JF - IEEE Access N2 - Scalability is often mentioned in literature, but a stringent definition is missing. In particular, there is no general scalability assessment which clearly indicates whether a system scales or not or whether a system scales better than another. The key contribution of this article is the definition of a scalability index (SI) which quantifies if a system scales in comparison to another system, a hypothetical system, e.g., linear system, or the theoretically optimal system. The suggested SI generalizes different metrics from literature, which are specialized cases of our SI. The primary target of our scalability framework is, however, benchmarking of two systems, which does not require any reference system. The SI is demonstrated and evaluated for different use cases, that are (1) the performance of an IoT load balancer depending on the system load, (2) the availability of a communication system depending on the size and structure of the network, (3) scalability comparison of different location selection mechanisms in fog computing with respect to delays and energy consumption; (4) comparison of time-sensitive networking (TSN) mechanisms in terms of efficiency and utilization. Finally, we discuss how to use and how not to use the SI and give recommendations and guidelines in practice. To the best of our knowledge, this is the first work which provides a general SI for the comparison and benchmarking of systems, which is the primary target of our scalability analysis. KW - communication networks KW - performance KW - availability KW - scalability Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-349403 VL - 11 ER - TY - JOUR A1 - Müller, Konstantin A1 - Leppich, Robert A1 - Geiß, Christian A1 - Borst, Vanessa A1 - Pelizari, Patrick Aravena A1 - Kounev, Samuel A1 - Taubenböck, Hannes T1 - Deep neural network regression for normalized digital surface model generation with Sentinel-2 imagery JF - IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing N2 - In recent history, normalized digital surface models (nDSMs) have been constantly gaining importance as a means to solve large-scale geographic problems. High-resolution surface models are precious, as they can provide detailed information for a specific area. However, measurements with a high resolution are time consuming and costly. Only a few approaches exist to create high-resolution nDSMs for extensive areas. This article explores approaches to extract high-resolution nDSMs from low-resolution Sentinel-2 data, allowing us to derive large-scale models. We thereby utilize the advantages of Sentinel 2 being open access, having global coverage, and providing steady updates through a high repetition rate. Several deep learning models are trained to overcome the gap in producing high-resolution surface maps from low-resolution input data. With U-Net as a base architecture, we extend the capabilities of our model by integrating tailored multiscale encoders with differently sized kernels in the convolution as well as conformed self-attention inside the skip connection gates. Using pixelwise regression, our U-Net base models can achieve a mean height error of approximately 2 m. Moreover, through our enhancements to the model architecture, we reduce the model error by more than 7%. KW - Deep learning KW - multiscale encoder KW - sentinel KW - surface model Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-349424 SN - 1939-1404 VL - 16 ER - TY - JOUR A1 - Liman, Leon A1 - May, Bernd A1 - Fette, Georg A1 - Krebs, Jonathan A1 - Puppe, Frank T1 - Using a clinical data warehouse to calculate and present key metrics for the radiology department: implementation and performance evaluation JF - JMIR Medical Informatics N2 - Background: Due to the importance of radiologic examinations, such as X-rays or computed tomography scans, for many clinical diagnoses, the optimal use of the radiology department is 1 of the primary goals of many hospitals. Objective: This study aims to calculate the key metrics of this use by creating a radiology data warehouse solution, where data from radiology information systems (RISs) can be imported and then queried using a query language as well as a graphical user interface (GUI). Methods: Using a simple configuration file, the developed system allowed for the processing of radiology data exported from any kind of RIS into a Microsoft Excel, comma-separated value (CSV), or JavaScript Object Notation (JSON) file. These data were then imported into a clinical data warehouse. Additional values based on the radiology data were calculated during this import process by implementing 1 of several provided interfaces. Afterward, the query language and GUI of the data warehouse were used to configure and calculate reports on these data. For the most common types of requested reports, a web interface was created to view their numbers as graphics. Results: The tool was successfully tested with the data of 4 different German hospitals from 2018 to 2021, with a total of 1,436,111 examinations. The user feedback was good, since all their queries could be answered if the available data were sufficient. The initial processing of the radiology data for using them with the clinical data warehouse took (depending on the amount of data provided by each hospital) between 7 minutes and 1 hour 11 minutes. Calculating 3 reports of different complexities on the data of each hospital was possible in 1-3 seconds for reports with up to 200 individual calculations and in up to 1.5 minutes for reports with up to 8200 individual calculations. Conclusions: A system was developed with the main advantage of being generic concerning the export of different RISs as well as concerning the configuration of queries for various reports. The queries could be configured easily using the GUI of the data warehouse, and their results could be exported into the standard formats Excel and CSV for further processing. KW - data warehouse KW - eHealth KW - hospital data KW - electronic health records KW - radiology KW - statistics and numerical data KW - medical records Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-349411 SN - 2291-9694 VL - 11 ER - TY - JOUR A1 - Seufert, Anika A1 - Poignée, Fabian A1 - Seufert, Michael A1 - Hoßfeld, Tobias T1 - Share and multiply: modeling communication and generated traffic in private WhatsApp groups JF - IEEE Access N2 - Group-based communication is a highly popular communication paradigm, which is especially prominent in mobile instant messaging (MIM) applications, such as WhatsApp. Chat groups in MIM applications facilitate the sharing of various types of messages (e.g., text, voice, image, video) among a large number of participants. As each message has to be transmitted to every other member of the group, which multiplies the traffic, this has a massive impact on the underlying communication networks. However, most chat groups are private and network operators cannot obtain deep insights into MIM communication via network measurements due to end-to-end encryption. Thus, the generation of traffic is not well understood, given that it depends on sizes of communication groups, speed of communication, and exchanged message types. In this work, we provide a huge data set of 5,956 private WhatsApp chat histories, which contains over 76 million messages from more than 117,000 users. We describe and model the properties of chat groups and users, and the communication within these chat groups, which gives unprecedented insights into private MIM communication. In addition, we conduct exemplary measurements for the most popular message types, which empower the provided models to estimate the traffic over time in a chat group. KW - communication models KW - group-based communication KW - mobile instant messaging KW - mobile messaging application KW - private chat groups KW - WhatsApp Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-349430 VL - 11 ER - TY - JOUR A1 - Salihoglu, Rana A1 - Srivastava, Mugdha A1 - Liang, Chunguang A1 - Schilling, Klaus A1 - Szalay, Aladar A1 - Bencurova, Elena A1 - Dandekar, Thomas T1 - PRO-Simat: Protein network simulation and design tool JF - Computational and Structural Biotechnology Journal N2 - PRO-Simat is a simulation tool for analysing protein interaction networks, their dynamic change and pathway engineering. It provides GO enrichment, KEGG pathway analyses, and network visualisation from an integrated database of more than 8 million protein-protein interactions across 32 model organisms and the human proteome. We integrated dynamical network simulation using the Jimena framework, which quickly and efficiently simulates Boolean genetic regulatory networks. It enables simulation outputs with in-depth analysis of the type, strength, duration and pathway of the protein interactions on the website. Furthermore, the user can efficiently edit and analyse the effect of network modifications and engineering experiments. In case studies, applications of PRO-Simat are demonstrated: (i) understanding mutually exclusive differentiation pathways in Bacillus subtilis, (ii) making Vaccinia virus oncolytic by switching on its viral replication mainly in cancer cells and triggering cancer cell apoptosis and (iii) optogenetic control of nucleotide processing protein networks to operate DNA storage. Multilevel communication between components is critical for efficient network switching, as demonstrated by a general census on prokaryotic and eukaryotic networks and comparing design with synthetic networks using PRO-Simat. The tool is available at https://prosimat.heinzelab.de/ as a web-based query server. KW - network simulation KW - protein analysis KW - signalling pathways KW - dynamic protein-protein interactions KW - optogenetics KW - oncolytic virus KW - DNA storage Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-350034 SN - 2001-0370 VL - 21 ER -