TY - THES A1 - Dakroub, Mohamad T1 - Coarsened Exact Matching of Excisional to Plasma-Ablative Ab Interno Trabeculectomy T1 - Vergröbertes genaues Matching von exzisionaler zu plasmaablativer Ab-Interno-Trabekulektomie N2 - Abstract Purpose: To compare ab interno trabeculectomy by trabecular meshwork excision to plasma-mediated ablation in primary open-angle glaucoma. Methods: Retrospectively collected data of TrabEx+ (n=56) and Trabectome (n=99) were compared by coarsened exact matching to reduce confounding and matched based on baseline intraocular pressure and age. Primary outcomes were intraocular pressure and the number of glaucoma medications. Complications and the need for additional glaucoma surgery were assessed. Patients were followed for up to one year. Results: 53 TrabEx+ could be matched to Trabectome. Baseline intraocular pressure was 16.5 ± 4.6 mmHg in both; age was 73.7 ± 8.8 years and 71.5 ± 9.9 years in TrabEx+ and Trabectome, respectively. TrabEx+ were taking more medications than Trabectome (p<0.001). Intraocular pressure was reduced to 14.8±4.3 in TrabEx+ and 13.4±3.4 in Trabectome at 6 months, and to 14.9±6.0 (p=0.13) in TrabEx+ and to 14.1±3.8 mmHg (all p<0.05) in Trabectome at 12 months. Medications were reduced at both 6 and 12 months (p< 0.05). No differences were seen between both groups at 6 and 12 months. In TrabEx+, only one serious complication occurred, and two patients required further glaucoma surgery. Conclusion: Although both groups had a baseline intraocular pressure considered low for ab interno trabeculectomy, intraocular pressure and medications were reduced further at 6 and 12 months. Intraocular pressure reduction did not reach significance in TrabEx+ at 12 months. The inter-group comparison did not reveal any significant differences. Both had a low complication rate. N2 - Das Glaukom wird initial häufig mit topischen Medikamenten behandelt. Es ist jedoch oft der Fall, dass Patienten im Verlauf operiert werden. Ablation, Exzision und Disruption des Trabekelmaschenwerks senken bei einem primären Offenwinkelglaukom den Augeninnendruck effektiv, wenn der Ausflusswiderstand im proximalsten Anteil des konventionellen Ausflusstraktes liegt. Die plasma-vermittelte Ablation des Trabekelmaschenwerks mit dem Trabektom steht Chirurgen seit 2004 zur Verfügung, während die Exzision mit dem TrabEx+ 2014 erstmals eingeführt wurde. Diese Studie zielte darauf ab, beide Geräte zu vergleichen und verwendete Coarsened Exact Matching, um kleine, gerätespezifische Unterschiede zwischen Trabektom und TrabEx+ festzustellen. Trotz eines relativ niedrigen Augeninnendrucks reduzierten beide Geräte diesen Parameter nach 6 Monaten signifikant, aber nur das Trabektom schaffte dies nach 12 Monaten. Beide reduzierten die Anzahl der drucksenkenden Medikamente zu beiden Zeitpunkten (6 und 12 Monate) signifikant. Definiert man den chirurgischen Erfolg als Abnahme des Augeninnendrucks um mehr als 20%, so waren die Erfolgsraten in beiden Gruppen relativ niedrig. Erklärbar ist dies am ehesten durch die niedrigen Ausgangswerte des Augeninnendrucks. In Bezug auf Augeninnendruck, Sehschärfe, Erfolgsraten und Komplikationen gab es keine wesentlichen Unterschiede zwischen beiden Geräten. TrabEx+ Patienten applizierten zu allen Zeitpunkten mehr drucksenkende Augentropfen als Trabektom-Patienten. KW - Glaukom KW - glaucoma KW - glaucoma surgery KW - trabex+ KW - trabectome Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-296805 ER - TY - JOUR A1 - Strzalkowska, A. A1 - Strzalkowski, P. A1 - Al Yousef, Y. A1 - Grehn, F. A1 - Hillenkamp, J. A1 - Loewen, Nils A. T1 - Exact matching of trabectome-mediated ab interno trabeculectomy to conventional trabeculectomy with mitomycin C followed for 2 years JF - Graefe's Archive for Clinical and Experimental Ophthalmology N2 - Purpose We used exact matching for a highly balanced comparison of ab interno trabeculectomy (AIT) with the trabectome to trabeculectomy with mitomycin C (TRAB). Methods A total of 5485 patients who underwent AIT were exact-matched to 196 TRAB patients by baseline intraocular pressure (IOP), number of glaucoma medications, and glaucoma type. Nearest-neighbor–matching was applied to age. Success was defined as a final IOP of less than 21 mmHg, IOP reduction of at least 20% reduction from baseline, and no secondary surgical interventions. Outcomes were measured at 1, 3, 6, 12, 18, and 24 months. Results A total of 165 AIT could be matched to 165 TRAB. The mean baseline IOP was 22.3 ± 5.6 mmHg, and the baseline number of glaucoma medications was 2.7 ± 1.1 in both groups. At 24 months, IOP was reduced to 15.8 ± 5.2 mmHg in AIT and 12.4 ± 4.7 mmHg in TRAB. IOP was lower than baseline at all visits (p < 0.01) and lower in TRAB than AIT (p < 0.01). Glaucoma medications were reduced to 2.1 ± 1.3 in AIT and 0.2 ± 0.8 in TRAB. Compared to baseline, patients used fewer drops postoperatively (p < 0.01) and more infrequently in TRAB than in AIT (p > 0.01). Secondary surgical interventions had the highest impact on success and became necessary in 15 AIT and 59 TRAB patients. Thirty-two challenging events occurred in TRAB and none in AIT. Conclusion Both AIT and TRAB reduced IOP and medications. This reduction was more significant in TRAB but at the expense of four times as many secondary interventions. KW - trabeculectomy KW - Ab interno trabeculectomy KW - trabectome KW - exact matching Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235224 SN - 0721-832X VL - 259 ER - TY - JOUR A1 - Yousef, Yousef Al A1 - Strzalkowska, Alicja A1 - Hillenkamp, Jost A1 - Rosentreter, André A1 - Loewen, Nils A. T1 - Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching JF - Graefe's Archive for Clinical and Experimental Ophthalmology N2 - Purpose To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching. Methods Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification. Results A total of 78 eyes (39 in each group) could be matched as exact pairs with a baseline IOP of 18.3 ± 5.1 mmHg and glaucoma medications of 2.7 ± 1.2 in each. IOP in IS2 was reduced to 14.6 ± 4.2 mmHg at 3 months and in T to a minimum of 13.1 ± 3.2 mmHg at 1 month. In IS2, IOP began to rise again at 6 months, eventually exceeding baseline. At 24 months, IOP in IS2 was 18.8 ± 9.0 mmHg and in T 14.2 ± 3.5 mmHg. IS2 had a higher average IOP than T at all postoperative visits (p < 0.05 at 1, 12, 18 months). Glaucoma medications decreased to 2.0 ± 1.5 in IS2 and to 1.5 ± 1.4 in T. Conclusion T resulted in a larger and sustained IOP reduction compared with IS2 where a rebound occurred after 6 months to slightly above preoperative values. KW - glaucoma surgery KW - iStent KW - trabecular bypass stent KW - trabectome KW - ab interno trabeculectomy KW - exact matching Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-232613 SN - 0721-832X VL - 258 ER -