TY - THES A1 - Mausolf, Nils Henrik T1 - Klinische und radiologische Ergebnisse nach Hüftprothesenwechsel durch Implantation eines kranial aufgesockelten Revisionspfannensystems T1 - Clinical and radiological outcome of acetabular cup revisions by using a cranial raised press-fit cup N2 - Background and issue: During the last years there was an increase of acetabular cup revisions. Furthermore the quality of life in elderly patients gains importance. Particularly challenging for orthopaedic surgeons is the treatment of extended acetabular defects. This study examines the clinical and radiological outcome of acetabular cup revisions by using a cranial raised press-fit cup. Additionally potential influencing factors were surveyed. Methods: In a retrospective monocentric study 155 patients, who underwent an acetabular cup revision by implanting an oval press-fit cup between 2009 and 2016 were reviewed and scored. An ethical clearance certificate of the University of Wuerzburg was given. Results: The mean follow-up was 53 months. 9 AAOS I defects, 25 AAOS II defects, 100 AAOS III defects and 21 AAOS IV defects were examined. The cumulative cup survival rate by using the Kaplan-Meier-Method was 93,4% (CI 89,1-97,6%). The survival rate without any revision was 84,0% (CI 77,9-90,1%). A significant reduction of pain on a numeric analogue scale could be proven (5,9 preoperative vs. 1,1 postoperative). The Harris-Hip Score increased significantly from 56,4 preoperative to 73,2 postoperative. In addition an improvement of all dimensions of the Euroqol could be confirmed. The overall state of health was measured by using the SF-12. As a result there was a slightly lower physical health and a slightly higher mental health compared to the reference population. Significant factors of influence on the outcome were detected: Male gender is associated with a higher functional outcome (HHS 87,7 vs. 74,2). Moreover, men numbered their level of pain lower than women did (NAS 0,65 vs. 1,5). Furthermore an association between more extended types of acetabular defects and a lower functional outcome could be confirmed. Additionally the factor age was found to create a significant influence on the functional outcome of the surgery. Patients below the age of 70 years upon the time of surgery reached higher results in Harris-Hip Score than older patients (82,2 vs. 77,3). Septic loosening was associated with a lower functional outcome than aseptic loosening (HHS 74,6 vs. 81,9). Conclusion: By analysing the survival rate, the improvement of function and the reduction of pain, good short- to midterm results were calculated for the surveyed implant system. Factors with a significant influence on the functional outcome were found to be: Gender, underlying type of defect, age upon surgery, septic or aseptic loosening. N2 - Fragestellung: Epidemiologisch zeigt sich seit einigen Jahren ein Anstieg der Fallzahlen von Hüftpannenrevisionen. Zudem gewinnt die Lebensqualität der älter werdenden Bevölkerung zunehmend an Bedeutung. Eine Herausforderung für den behandelnden Chirurgen stellt insbesondere die Versorgung von größeren acetabulären Defekten dar. In dieser Studie wurden klinische und radiologische Ergebnisse von Hüftpfannenrevisionen, die durch ein kranial aufgesockeltes, längsovales Revisionspfannensystem versorgt wurden, untersucht. Ferner sollten mögliche Einflussfaktoren auf das Operationsergebnis ermittelt werden. Methodik: In einer retrospektiven monozentrischen Studie wurden 155 Patienten, die im Zeitraum von 2009 bis 2016 mit Kranialpfannen versorgt wurden, nachuntersucht und Scores erhoben. Ein Unbedenklichkeitsbescheid der Ethikkommission der Universität Würzburg lag vor. Ergebnisse: Das Follow-up lag im Durchschnitt bei 53 Monaten. Es wurden 9 AAOS I Defekte, 25 AAOS II Defekte, 100 AAOS III Defekte und 21 AAOS IV-Defekte nachuntersucht. Das kumulative Gesamtüberleben nach Kaplan-Meier betrug für diesen Follow-up Zeitraum 93,4% (CI 89,1-97,6%). Das revisionsfreie Überleben lag bei 84,0% (CI 77,9-90,1%). Es konnte eine signifikante Schmerzreduktion auf einer visuellen Analogskala belegt werden (5,9 präoperativ vs. 1,1 postoperativ). Der Harris-Hip-Score verbesserte sich hochsignifikant von 56,4 präoperativ auf 73,2 postoperativ. Ferner konnte in allen Dimensionen des Euroqols eine signifikante Verbesserung nachgewiesen werden. Der Gesundheitszustand der Patienten wurde anhand des SF-12 bestimmt. Als Ergebnis zeigte sich verglichen mit der Referenzpopulation eine leicht erniedrigte physische Gesundheit und eine geringgradig erhöhte psychische Gesundheit. Im Rahmen dieser Arbeit konnten einige signifikante Einflussfaktoren auf das Operationsergebnis ermittelt werden: Das männliche Geschlecht ist mit einem signifikant besseren funktionellen Outcome assoziiert (HHS 87,7 vs. 74,2). Zudem gaben Männer auf der visuellen Analogskala eine signifikant geringere Schmerzintensität an (0,65 vs. 1,5). Darüber hinaus konnte belegt werden, dass höhergradige Defekttypen mit einem schlechteren funktionellen Outcome vergesellschaftet sind. Das funktionelle Outcome unterscheidet sich zudem signifikant in Abhängigkeit vom Alter der Patienten zum Zeitpunkt der Operation. Patienten unter 70 Jahren erreichten im Durchschnitt signifikant höhere Punktzahlen im Harris-Hip-Score (82,2 vs. 77,3). Septische Indikationen standen verglichen mit aseptischen Lockerungen ebenfalls in Assoziation mit einem schlechteren funktionellen Outcome (HHS 74,6 vs. 81,9). Schlussfolgerung: Anhand der im Zuge dieser Arbeit ermittelten Überlebensrate, einer Verbesserung der Funktionalität im Hüftgelenk und einer nachgewiesenen Schmerzreduktion konnten gute kurz- bis mittelfristige Ergebnisse für das vorliegende Implantatsystem gezeigt werden. Als Einflussfaktoren auf das klinische Outcome konnten das Geschlecht, der zugrunde liegende Defekttyp, das Alter zum OP-Zeitpunkt und eine septische oder aseptische Indikation ermittelt werden. KW - Hüftprothese KW - Hip KW - Revision KW - Acetabular KW - Press-fit KW - Hüfte KW - Hüftpfanne KW - Revision KW - Kranialpfanne Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217218 ER - TY - THES A1 - Roller, Christian T1 - Abriebverhalten der Harris-Galante-Pfanne in Kombination mit 28mm Keramik- und Metallköpfen T1 - Wear behavior of the Harris-Galante-Acetabular-Cup in Kombination with 28mm Ceramic- and Metal-Heads N2 - Obwohl Simulatoruntersuchungen geringere Abriebwerte für Keramik-Köpfe gezeigt haben, konnten klinische Studien diese Erkenntnisse bisher nicht bestätigen. Bisher existiert keine Studie mit einer angemessenen Teststärke, die das Abriebverhalten von 28 mm CoCr- und Biolox-Köpfen vergleicht. Ziel dieser Studie war es, das in-vivo-Abriebverhalten von Keramik- und Metall-Köpfen in Verbindung mit der Harris-Galante-Pfanne zu untersuchen. Bei allen Patienten wurde ein zementfreies Pfannenimplantat nach Harris-Galante (Zimmer) implantiert. Die Inlays bestanden aus konventionell gefertigtem UHMWPE. 108 Patienten erhielten CoCr-Köpfe, 99 weitere Patienten wurden mit Keramik-Köpfen (Biolox) versorgt. Die 2D-Abriebrate wurde mit der Hip-analysis-suite von Martell über einen Zeitraum von 5,2 Jahren bei den Biolox- beziehungsweise 8 Jahren bei den CoCr-Köpfen untersucht. Die Metall-Köpfe zeigten einen linearen Abrieb von 0,14  0,11 mm pro Jahr, verglichen mit 0,13  0,08 mm pro Jahr bei den Keramik-Köpfen. Dieser Unterschied war, insbesondere nach Anpassung an die klinischen Einflussfaktoren, nicht signifikant (p = 0,46). Die Power-Analyse zeigte eine Teststärke von 80%, einen Unterschied von 28% (0,038 mm pro Jahr) zu detektieren. Die vorliegende Studie ist die erste, die das Abriebverhalten von 28 mm Metall- und Keramik-Köpfen im gleichen Pfannenimplantat mit ausreichender Teststärke vergleicht. Mit einer Teststärke von 80%, eine Abriebreduktion um 28% zu erkennen, zeigt diese Studie keinen Unterschied zwischen Biolox- und Metall-Köpfen in Verbindung mit konventionellen UHMWPE-Inlays in einer modularen Pfanne. N2 - Although hip simulator testing shows decreased wear with alumina ceramic femoral heads, several clinical series have not supported this finding. To our knowledge, no published series exists with adequate power to compare 28 mm alumina vs. cobalt chrome wear rates. Our purpose is to compare the in-vivo clinical performance of alumina and cobalt chrome femoral bearings in the Harris-Galante-Acetabular -Cup. Patients underwent primary cementless hip replacement using the HGP-I and II acetabular components (Zimmer) with 28 mm bearings and conventional ultra high molecular weight polyethylene liners. 108 implants received cobalt-chrome bearings while 99 received alumina (Biolox) bearings. 2D linear wear rates were calculated using Hip-analysis-suite developed by Martell et al. The Biolox-heads were followed up for 5,2 years, the CoCR-heads were followed up for 8 years. The metal bearings demonstrated a mean linear wear rate of 0.14 mm/yr. +/- 0.11 mm/yr., compared to 0.13 mm/yr. +/- 0.08 mm/yr. for alumina. This difference was not significant after adjusting for covariates and using the non-parametric Mann-Whitney test (p= 0.46). Post-hoc power analysis indicated 80% power to detect a 0.038 mm/yr. (28%) difference in wear rates. This is the first study with adequate power to assess wear between 28 mm alumina and cobalt chrome femoral heads. With 80% power to detect a 28% wear reduction, our series shows no advantage in wear performance for alumina ceramics on conventional UHMWPE in a modular cup design. KW - Abrieb KW - Hüftgelenk KW - Harris-Galante KW - Osteolysen KW - Polyethylen KW - Wear KW - Hip KW - Harris-Galante KW - Oseolysis KW - Polyethelen Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-14197 ER - TY - THES A1 - Roth, Franz T1 - Verlauf des funktionellen Ergebnisses sowie der Lebensqualität der Patienten im ersten Jahr nach Implantation einer Hüfttotalendoprothese über den lateralen Standard-Zugang nach Bauer T1 - Functional results and qualitiy of life of patients in the first year after implantation of a total hip prosthesis using a transgluteal lateral approach (Bauer) N2 - Background: Diese prospektiv randomisierte kontrollierte Single-Center-Studie untersucht das klinische Outcome 3 bis 12 Monate nach Implantation einer Hüfttotalendoprothese über den transglutealen lateralen Hüftzugang (Bauer). Methods: 77 Patienten wurden in die transgluteale laterale Zugangsweg Kohorte randomisiert, wovon 50 Patienten die Studie beendeten. Alle Patienten wurden mit dem Harris Hip Score (HHS), dem Xtra Short Musculosceletal Functional Assesment Questionaire (XSFMA), dem 36-Item Short Form Survey (SF-36), einem Stepwatch™-Aktivitätsmonitor (SAM) und einem zeitabhängigen 25m-Gehtest bewertet. Mit Hilfe der postoperativen Standard- röntgenaufnahmen wurde die Inklination, Schaftpositionierung und das Offset bewertet. Results: Unsere Patienten verbesserten sich nach drei Monaten in Bezug auf den 25-m-Gehtest (prä-operativ 24 Sekunden, SD ± 6,07, 3 Monate 19,36 Sekunden, SD ± 3,80) und die vom Patienten geschätzte maximale Gehstrecke nicht signifikant (präoperativ 1187, SD ± 1809m und 12 Monate 5125m, SD ± 3867m). Mit der Stepwatch konnte ein postoperativer Anstieg der mittleren Gehzyklen pro Tag gemessen werden (präoperativ 4964, SD ± 2687, 3 Monate 5238, SD ± 2309, 12 Monate 5340, SD ± 1887). Der Bewegungsumfang verbesserte sich insbesondere für die Flexion (präoperativ 89°, 3 Monate 97,34°) und die Abduktion (präoperativ 25,31°, 3 Monate 37,45°) und blieb im weiteren Verlauf nahezu unverändert. Der HHS zeigte einen signifikanten Unterschied zwischen dem präoperativen Score (52,95, SD ± 15,69) und den Scores aller postoperativen Messzeitpunkte (3 Monate 88,40, SD ± 9,89, 6 Monate 89,05, SD ± 10,01, 12 Monate 91,43, SD ± 9,05, p <0,001). Gleiches gilt für den XSFMA-Funktionsindex, der sich zwischen dem präoperativen Score (40,50, SD ± 15,78) und den postoperativen Scores signifikant verbesserte (3 Monate 18,80, SD ± 16,12, 6 Monate 15,84, SD ± 15,39, 12 Monate 15,08, SD ± 16,33, p<0.001). Der SF-36-Score mit der Subgruppe der körperlichen Verfassung betrug präoperativ 25,62, SD ± 8,74 und war postoperativ ebenfalls signifikant höher (3 Monate 40,67, SD ± 10,01, 6 Monate 42,76, SD ± 9,59, 12 Monate 42,91, SD ± 11,86, p < 0,05), während der Subscore der psychischen Beurteilung sich stets auf konstantem Niveau befand (präoperativ 56,26, SD ± 9,23, 3 Monate 56,68, SD ± 8,23, 6 Monate 55,81, SD ± 7,22, 12 Monate 56,23, SD ± 6,92, p <0,05). Die Bewertung der postoperativen Röntgenbildgebung ergab eine durchschnittliche Pfanneninklination von 40,28 ° und einen femorales Offset von 38,1mm ohne Anzeichen von Migration. Conclusion: Zusammenfassend zeigen unsere Ergebnisse, dass sich bereits drei Monate nach Implantation einer Totalhüftendoprothese über den transglutealen lateralen Zugang die Lebensqualität, das Aktivitätsniveau, die Patientenzufriedenheit und der postoperative Bewegungsumfang signifikant verbessert haben. Trial registration: DRKS00014808 (German Clinical Trial Register DRKS); date of registration: 31.05.2018. N2 - Background: This prospective randomized controlled single-centre study investigates the clinical outcome 3 up to 12 months after total hip arthroplasty using a transgluteal lateral approach (Bauer). Methods: 77 patients were randomized to the transgluteal lateral approach cohort and 50 of them completed the trial. All patients were evaluated using the Harris Hip Score (HHS), the extra short musculoskeletal functional assessment questionnaire (XSFMA), the Short Form 36 (SF-36) health survey, a Stepwatch™ Activity Monitor (SAM), and a timed 25 m walking test. On standard postoperative radiological x-rays the inclination and stem-positioning was evaluated. Results: Our patients improved non significantly after three months regarding to the 25 m walking test (pre-op 24 sec., SD ± 6.07, 3-months 19,36 sec., SD ± 3.80) and to the expected maximal walking distance, guessed by the patient (pre-op 1187, SD ± 1809m and 12-month 5125m, SD ± 3867m). Using the Stepwatch a postoperative increase of the mean walking cycles per day was measured (pre-op 4964, SD ± 2687, 3-month 5238, SD ± 2309, 12-month 5340, SD ± 1887). Range of motion improved especially in relation to flexion (pre-op 89°, 3-month 97,34°) and abduction (pre-op 25.31°, 3-month 37.45°) and showed just slight improvement during the 6- and 12-month follow up. The HHS showed a significant difference between the preoperative score (52.95, SD ± 15.69) and the scores to all postoperative measurement times (3-month 88.40, SD ± 9.89, 6-month 89.05, SD ± 10.01, 12-month 91.43, SD ± 9.05, p<0.001). Same did the XSFMA functional index score which improved significantly between the preoperative score (40.50, SD ± 15.78) and the postoperative scores (3-month 18.80, SD ± 16.12, 6-month 15.84, SD ± 15.39, 12-month 15.08, SD ± 16.33, p<0.001). The SF-36 physical component score was 25.62, SD ± 8.74 pre-operatively and rised significantly (3-month 40.67, SD ± 10.01, 6-month 42.76, SD ± 9.59, 12-month 42.91, SD ±11.86, p<0.05 ) while the mental component score was almost equal during the whole trial (pre-op 56.26, SD ± 9.23, 3-month 56.68, SD ± 8.23, 6-month 55.81, SD ± 7.22, 12-month 56.23, SD ± 6.92, p<0.05). The radiographic analysis revealed an average cup inclination of 40.28° and a femoral offset of 38.1mm without signs of migration. Conclusion: In summary, our outcomes show that already three months after the implantation of a total hip arthroplasty via a transgluteal lateral approach the patients improved significantly regarding to the quality of life, level of activity, satisfaction and postoperative range of motion. Trial registration: DRKS00014808 (German Clinical Trial Register DRKS); date of registration: 31.05.2018. KW - Hüftendoprothetik KW - Endoprothetik KW - Zugangswege KW - Total hip arthroplasty KW - Transgluteal approach KW - Prospective Study KW - Arthroplasty KW - Hip KW - Bauer KW - Transglutealer Zugang Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-203878 ER -