TY - THES A1 - Glaab, Fabian T1 - Simulationen zur transienten Absorptionsspektroskopie an Energie- und Ladungstransfersystemen T1 - Simulations on transient absorption spectroscopy of energy and charge transfer systems N2 - Anregungsinduzierte Ladungstransferprozesse gemischtvalenter Verbindungen in einem, bzw. zwei Vibrationsfreiheitsgraden werden mithilfe vibronischer Modellsysteme untersucht. Anhand transienter und linearer Absorptionsspektren werden die berechneten mit experimentell bestimmten Daten verglichen. Eine detailliertere theoretische Analyse erfolgt unter den Gesichtspunkten der Populations- und Wellenpaketdynamik. Darüber hinaus wird der Prozess der Exziton-Exziton-Annihilierung mithilfe eines elektronischen Modellsystems untersucht. Zu diesem Zweck werden, zusätzlich zu den oben genannten Methoden, spektroskopische Signale unterschiedlicher Emissionsrichtungen zum Vergleich herangezogen. N2 - Optically induced charge transfer processes of mixed-valence compounds in one or two vibrational degrees of freedom respectively are studied using vibronic model systems. Calculated and experimentally determined data are compared based on transient as well as linear absorptions spectra. By means of population and wave-packet dynamics a more detailed theoretical analysis is performed. Furthermore, the process of exciton-exciton annihilation is studied using an electronic model system. Therefore, in addition to the methods mentioned above, spectroscopic signals in different directions of emission are compared. KW - Absorptionsspektroskopie KW - Monte-Carlo-Simulation KW - Ladungstransfer KW - Exziton KW - Transiente Absorptionsspektroskopie KW - Exziton-Exziton-Anihillierung KW - Nicht-Störungstheoretisch Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-253400 ER - TY - THES A1 - Scheuermann, Julian T1 - Interbandkaskadenlaser für Anwendungen in der Absorptionsspektroskopie T1 - Interband cascade lasers for applications in absorption spectroscopy N2 - Das Ziel dieser Arbeit war die Entwicklung und Weiterentwicklung von Laserlichtquellen basierend auf der Interbandkaskadentechnologie in einem Wellenlängenbereich von ca. 3 bis 6 µm. Der Fokus lag dabei auf der Entwicklung von Kantenemitter-Halbleiterlasern, welche bei verschiedensten Emissionswellenlängen erfolgreich hergestellt werden konnten. Dabei wurde auf jeweilige Herausforderungen eingegangen, welche entweder durch die Herstellung selbst oder der anwendungstechnischen Zielsetzung bedingt war. Im Rahmen dieser Arbeit wurden verschiedene, spektral einzelmodige Halbleiterlaser im angesprochenen Wellenlängenbereich entwickelt und hergestellt. Basierend auf dem jeweiligen Epitaxiematerial und der angestrebten Emissionswellenlänge wurden Simulationen der optischen Lasermode durchgeführt und die grundlegenden für die Herstellung notwendigen Parameter bestimmt und experimentell umgesetzt. Des Weiteren wurden die verwendeten Verfahren für den jeweiligen Herstellungsprozess angepasst und optimiert. Das umfasst die in den ersten Kapiteln beschriebenen Schritte wie optische Lithografie, Elektronenstrahllithografie, reaktives Trockenätzen und verschiedene Arten der Materialdeposition. Mit einer Emissionswellenlänge von 2,8 µm wurde beispielsweise der bislang kurzwelligste bei Raumtemperatur im Dauerstrichbetrieb betriebene einzelmodige Interbandkaskadenlaser hergestellt. Dessen Leistungsmerkmale sind mit Diodenlasern im entsprechenden Emissionsbereich vergleichbar. Somit ergänzt die Interbandkaskadentechnologie bestehende Technologien nahtlos und es ist eine lückenlose Wellenlängenabdeckung bis in den mittleren Infrarotbereich möglich. Je nach Herstellungsprozess wurde außerdem auf die verteilte Rückkopplung eingegangen und die Leistungsfähigkeit des verwendeten Metallgitterkonzeptes anhand von Messungen an spektral einzelmodigen Bauteile aufgezeigt. Es wurden aber auch die je nach Zielsetzung unterschiedlichen Herausforderungen aufgezeigt und diskutiert. Für eine Anwendung wurden spezielle Laserchips mit zwei einzelmodigen Emissionswellenlängen bei 3928 nm und 4009 nm entwickelt. Die beiden Wellenlängen sind für die Detektion von Schwefeldioxid und Schwefelwasserstoff geeignet, welche zur Überwachung und Optimierung der Schwefelgewinnung durch das Claus-Verfahren notwendig sind. Bei der Umsetzung wurden auf einzelnen Chips zwei Laseremitter in einem Abstand von 70 µm platziert und mit je einem Metallgitter versehen. Das verwendete Epitaxiematerial war so konzipiert, dass es optimal für beide Zielwellenlängen verwendet werden kann. Die geforderten Eigenschaften wurden erfüllt und die Bauteile konnten erfolgreich hergestellt werden. Die Emissionseigenschaften und das spektrale Verhalten wurde bei beiden Zielwellenlängen bestimmt. Einzeln betrachtet erfüllen beide Emitter die notwendigen Eigenschaften um für spektroskopische Anwendungen eingesetzt werden zu können. Ergänzend wurde zum einen das Abstimmverhalten der Emissionswellenlänge in Abhängigkeit der Modulationsfrequenz des Betriebsstromes untersucht und zusätzlich die thermische Abhängigkeit der Betriebsparameter beider Kanäle zueinander bestimmt. Diese Abhängigkeit ist für eine simultane Messung mit beiden Kanälen notwendig. Das Konzept mit mehreren Stegwellenleitern pro Laserchip wurde in einem weiteren Fall noch stärker ausgearbeitet. Denn je nach Komplexität eines Gasgemisches sind zur Bestimmung der einzelnen Komponenten mehr Messpunkte bzw. Wellenlängen notwendig. Im zweiten Fall ist die Analyse der Kohlenwasserstoffe Methan, Ethan, Propan, Butan, Iso-Butan, Pentan und Iso-Pentan von Interesse, welche als Hauptbestandteile von Erdgas z.B. in Erdgasaufbereitungsanlagen oder zur Bestimmung des Heizwertes analysiert werden müssen. Die genannten Kohlenwasserstoffe zeigen ein starkes Absorptionsverhalten im Wellenlängenbereich von 3,3 bis 3,5 µm. Auf dem entsprechend angepassten Interbandkaskadenmaterial wurden Bauteile mit neun Wellenleitern pro Laserchip hergestellt. Mithilfe der neun einzelmodigen Emissionskanäle konnte ein Bereich von bis zu 190 nm (21 meV, 167 cm-1) adressiert werden. Außerdem wurde der sich mit zunehmender Wellenlänge ändernde Schichtaufbau und dessen Einfluss auf die Bauteileigenschaften diskutiert. Die Leistungsdaten der langwelligsten Epitaxie waren im Vergleich deutlich schwächer. Um diesen Nachteil zu kompensieren, wurde eine spezielle Wellenleitergeometrie mit doppeltem Steg genutzt. Die Eigenschaften des Konzeptes wurden zuerst mittels Simulation untersucht und ein entsprechendes Herstellungsverfahren entwickelt. Mit der Simulation als Grundlage wurden die verschiedenen Prozessparameter über mehrere Prozessläufe iterativ optimiert und somit die Performance der Laser verbessert. Auch mit diesem Verfahren konnte ausreichende Kopplung an das Metallgitter erzielt werden. Abschließend wurden mit diesem Herstellungsverfahren einzelmodige Laser im Wellenlängenbereich von 5,9 bis über 6 Mikrometern realisiert. Diese Laser emittierten im Dauerstrichbetrieb bei einer maximalen Betriebstemperatur von -2 °C. Insgesamt wurde anhand der im Rahmen dieser Arbeit entwickelten Bauteilen und de ren Charakterisierung gezeigt, dass diese die Anforderungen von TLAS Anwendungen erfüllen. Jedoch konnte nur auf einen Teil der Möglichkeiten eingegangen werden, den die Interbandkaskadentechnologie bietet, denn die angesprochenen Einsatzgebiete stellen nur einzelne grundlegende Möglichkeiten dieser Technologie mit Schwerpunkt auf laserbasierte Lichtquellen dar. Zusammenfassend kann allerdings gesagt werden, dass sich die Interbandkaskadentechnologie etabliert hat. Gerade durch die gezeigten Leistungsdaten bei den Wellenlängen um 2,9 µm, 3,4 µm und 4,0 µm im Dauerstrichbetrieb bei Raumtemperatur wird ersichtlich, dass im Bereich der Sensorik die ICL Technologie in Bezug auf niedriger Strom- bzw. Leistungsaufnahme quasi konkurrenzlos ist. Sicherlich werden die Anwendungsgebiete in Zukunft noch vielfältiger. Denn es sind auf jeden Fall weitere Fortschritte in Richtung höherer Emissionswellenlängen, deutlich höherer Betriebstemperaturen, verbreiterte Emissionsbereiche oder gänzlich andere Bauteil Konzepte wie z.B. für Frequenzkämme bzw. Terahertz Anwendungen zu erwarten. Diese Entwicklung betrifft nicht nur den Einsatz als Lichtquelle, denn auch Interbandkaskadendetektoren bzw. Solarzellen wurden schon realisiert und werden weiterentwickelt. N2 - The work aimed for the development and enhancement of laser sources in the wavelength range from 3 to 6 μm, based on the interband cascade technology. The focus here was to work on edge-emitting semiconductor lasers, which were successfully realized at various wavelengths. In each chapter, the respective challenges were discussed, resulting either from the fabrication process itself or from the underlying application requirements. Within the scope of this work, various spectrally single-mode semiconductor lasers were developed and fabricated within the abovementioned wavelength range. Based on the particular epitaxial material and the targeted emission wavelength, optical mode simulations were performed, the basic processing parameters were derived and later experimentally realized. Furthermore, the methods for the respective manufacturing processes were varied and optimized. This includes processing steps like optical lithography, electron lithography, reactive ion etching and various kinds of material deposition, as described in the first chapters. For example, with an emission wavelength of 2.8 μm in continuous wave mode at room temperature, we demonstrated the shortest ICL DFB emission [SWE+15]. Its performance characteristics are comparable to conventional diode lasers in the same wavelength region. Therefore, the interband cascade technology supplements existing technologies and enables gap-free wavelength coverage up to the mid infrared region. Depending on the fabrication process, the distributed feedback and the efficiency of the used metal grating approach was shown by the demonstration of various spectrally singe mode devices and their performance figures. The various challenges were highlighted in terms of their individual requirements. Customized laser chips with two single-mode emission wavelengths at 3928 nm and 4009 nm were developed for one application [SWB+17]. Both wavelengths are useful for the detection of sulfur oxide and hydrogen sulfide within the Claus process, allowing monitoring and optimization when the concentration levels of these gases are known. Both emitters were realized on single chips, with a distance of 70 μm between each other and each ridge was provided with an individual metal grating. The underlying epitaxial material was designed that it could be optimally used for both target wavelengths. Ultimately, the requirements were met and the devices were fabricated successfully. The performance figures and the spectral behavior were determined at both target wavelengths. Individually, both emitters are capable of being used in spectroscopic applications. In addition, the tuning rate of the emission wavelength depending on the current modulation frequency and the thermal crosstalk between both emitters were investigated. Knowledge of the thermal crosstalk is of interest, when both emitters are used simultaneously. The concept of multiple ridge waveguides per laser chip was further elaborated in another case. Depending on the complexity of the gas mixture, more measurement points/wavelengths are required, to determine the individual components. In a second approach, mixtures of hydrocarbons such as methane, ethane, propane, butane, isobutene, pentane and isopentane are of interest. These main components of natural gas are tracked in natural gas processing plants, for example, or used to determine the calorific value. These hydrocarbons show strong absorption features in the 3.3 to 3.5 μm wavelength range. Devices with nine emitters per chip were fabricated on the appropriately adjusted epitaxial material. These nine single mode emission channels were able to cover a range of 190 nm (21 meV, 167 cm-1). In addition, the changes of the epitaxial structure with respect to increasing emission wavelength and their influence on the device behavior are discussed. The performance data of the longest wavelength epitaxy were significantly weaker in comparison. To compensate for that drawback, a special waveguide design with a double ridge structure was used. The properties of this concept were first investigated by means of simulation and an appropriate processing route was determined. Using the simulation as a basis, the design parameters were iteratively optimized over multiple fabrication runs and the performance of the lasers was improved. With this approach, sufficient coupling of the laser mode to the metal grating was also realized. Finally, single-mode lasers in the wavelength range from 5.9 to over 6 μm were realized using the double ridge fabrication technique. These lasers were operated in continuous wave mode at a maximum operation temperature of -2 °C. Overall, the devices developed within this work and their characteristics show, that the requirements for TLAS applications are met. However, only a part of the possibilities of the interband cascade technology could be addressed, since the discussed application areas are focused on laser-based light sources. In summary, interband cascade technology has established itself. In particular, the performance data at 2.9 μm, 3.4 μm and 4.0 μm in continuous wave operation at room temperature show that the ICL technology is almost unrivaled in terms of low current/power consumption. Certainly, the areas of application will be even more diverse in the future. Further progress in terms of higher emission wavelengths, higher operation temperatures, and broadband wavelength emission can be expected. Other concepts such as frequency combs [BFS+18, SWP+17] or terahertz [VM99] emission can also be realized. This development does not only concern the light sources, also interband cascade detectors or solar cells [YTK+10, HTR+13, TK15, HLL+18, LLL+17a, LLL+17b] have already been realized and are being further developed. KW - Halbleiterlaser KW - Interbandkaskadenlaser KW - Absorptionsspektroskopie Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-251797 ER - TY - THES A1 - Hartleb, Holger Edgar Heinz Erich T1 - Spektroelektrochemische Untersuchung von halbleitenden Kohlenstoffnanoröhren T1 - Spectroelectrochemical investigation of semiconducting carbon nanotubes N2 - Der Schwerpunkt dieser Arbeit lag auf der spektroelektrochemischen Untersuchung von halbleitenden SWNTs. Hierbei wurden erstmalig Absorptions- und Photolumineszenzspektren ein und derselben SWNT-Probe simultan unter elektrochemischer Potentialkontrolle aufgenommen. Hierbei konnte gezeigt werden, dass die Messmethode einen entscheidenden Einfluss auf die erhaltene Bandlücke besitzt und der in der Literatur geprägte Begriff der Elektrochemischen Bandlücke aufgrund einer fehlenden allgemeingültigen Definition problembehaftet ist. So ergeben Photolumineszenzmessungen im Vergleich zu Raman- oder Absorptionsmessungen die kleinste Bandlücke. Dies wurde auf die diffusionskontrollierte Löschung der Exzitonen an Ladungszentren zurückgeführt. Weiterhin wurden die optischen Spektren von SWNTs unter Ladungseinfluss analysiert und die zugrundeliegenden Änderungen der elektronischen Eigenschaften diskutiert. Neben SWNTs wurden die Übergangsmetalldichalkogenide MoS2 und WS2 spektroelektrochemisch untersucht. Auffallend im Vergleich zu den Messungen an SWNTs war der breite Potentialbereich, über den die Abnahme der exzitonischen Signale zu beobachten war. Dies kann auf die unterschiedliche elektronische Struktur von TMDs und SWNTs und den geringen Anteil von Einzellagen in den TMD-Proben zurückgeführt werden. Weiterhin konnte in den Absorptionsspektren unter Ladungseinfluss ein Signal beobachtet werden, welches auf die Entstehung von Trionen hindeutet. In einem weiteren Teilprojekt wurde eine elektrochemische Zelle zur Untersuchung von metallischen SWNT-Filmen als Elektrode für die Wasserstoffproduktion entwickelt und getestet. Hierbei gelang es die von Das et al. publizierte Aktivierung von SWNTs mit Schwefelsäure erfolgreich nachzuvollziehen und einen katalytischen Effekt der SWNTs auf die Wasserstoffentwicklung zu beobachten. N2 - The main focus of this work was on spectroelectrochemical studies of semiconducting SWNTs. For the first time, absorption and photoluminescence spectra of one and the same sample were recorded simultaneous under electrochemical control of the potential. It was shown, that the optical method has a significant influence on the resulting band gap. Therefore, the term electrochemical band gap, which has developed in literature, is problematic due to a missing general definition. Photoluminescence measurements yield the smallest band gap in comparison to Raman or absorption measurements. This was attributed to the diffusion limited quenching of excitons at charges. Furthermore, the optical spectra of charged SWNTs were analysed and the underlying electronic changes were discussed. In addition to SWNTs, the transition metal dichalcogenides MoS2 and WS2 were studied with spectroelectrochemical methods as well. Striking, when compared to the measurements of SWNTs, was the broad potential range during which the decrease of the excitonic signals could be observed. This can be attributed to the different electronic structures of TMDs and SWNTs and the small amount of mono layers in the TMD samples. Under the influence of charges it was furthermore possible to observe a signal in the absorption spectra, which points to the formation of trions. In the last part of this work an electrochemical cell for the investigation of hydrogen production at metallic SWNT electrodes was developed and tested. The activation procedure of SWNTs with sulphuric acid, which was published by Das et al., was successfully reproduced, and a catalytic effect on the hydrogen production by the SWNTs was observed. KW - Kohlenstoff-Nanoröhre KW - Photolumineszenzspektroskopie KW - Absorptionsspektroskopie KW - Spektroelektrochemie KW - Übergangsmetalldichalkogenide KW - Elektrolyse KW - elektrochemische Bandlücke Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-116628 ER - TY - THES A1 - Margraf, Markus Johann T1 - Spektroskopie an π-konjugierten Molekülen T1 - Spectroscopy of π-conjugated molecules N2 - Femtosekunden-zeitaufgelöste transiente Absorptionsspektroskopie einer neutralen organischen gemischtvalenten Verbindung In einem Femtosekunden-zeitaufgelösten Anrege-Abfrage-Experiment wurde die Dynamik des Elektronentransfers einer neutralen organischen gemischtvalenten Verbindung untersucht. Neben der Abhängigkeit des Rückelektronentransfers von der Solvenspolarität wurde auch die Rotationsdiffusion in n-Hexan, Toluol, Dibutylether, tert-Butylmethylether und Benzonitril studiert. Die transiente Dynamik lässt sich mit einer Lebensdauer beschreiben, verursacht durch einen Rückelektronentransfer. Während dieser in unpolaren Lösemitteln relativ langsam verläuft, beobachtet man deutlich schnellere ET-Raten mit steigender Polarität des Lösemittels. Die Lebensdauer variiert von 1.2 ps für Benzonitril bis 260 ps für n-Hexan. Rotationsdiffusion konnte nicht beobachtet werden. Die gemessenen Raten wurden mit theoretischen Raten verglichen. Für unpolare Lösemittel konnte eine gute Übereinstimmung gefunden werden. In polaren Lösemitteln bewirkt eine Korrektur, die die Solvensrelaxationszeit berücksichtigt, eine sehr gute Übereinstimmung von berechneten und gemessenen Rückelektronentransferraten. Zeit- und frequenzaufgelöste Photoionisation des C 2A2-Zustandes des Benzylradikals Die Lebensdauer des C 2A2-Zustandes des Benzylradikals wurde in Abhängigkeit der Überschussenergie bestimmt. Die zeitabhängigen Ionensignale konnten dabei mit einer biexponentiellen Dynamik beschrieben werden. Bei einer Anregung am Ursprung (305nm) betragen die Lebensdauern τ1= 400 fs und τ2 = 4.5 ps. Die kürzere Lebensdauer τ1 beschreibt die interne Konversion vom C-Zustand zu den stark koppelnden A/B-Zuständen, die längere Lebensdauer τ2 die interne Konversion von den A/B-Zuständen in den elektronischen Grundzustand. Mit steigender Anregungsenergie beobachtet man eine stete Abnahme beider Lebensdauern. Bei einer Anregung mit einem Puls der Wellenlänge von 301 nm beobachtet man deutlich kürzere Lebensdauern mit τ1 = 350 fs und τ2 = 2.8 ps. Erfolgt die Anregung mit einem Puls der Wellenlänge von 298 nm, betragen die Zeitkonstanten τ1 = 180 fs und τ2 = 2.1 ps. Desweiteren konnte ein zeitabhängiges Ionensignal für eine Spezies mit der Zusammensetzung C7H5 beobachtet werden. Der Träger des Signals ist das Fulvenallenylradikal. N2 - Femtosecond time-resolved transient absorption spectroscopy of a neutral organic mixed-valenced compound The dynamics of electron transfer of a neutral organic mixed-valence compound was investigated by femtosecond transient absorption spectroscopy. Both dependence of back-electron transfer on solvent polarity and rotational diffusion was studied in n-hexane, toluene, dibutylether, methyl-tert-butyl ether and benzonitrile. The transient kinetics is governed by one time constant which is assigned to back-electron transfer. It ranges from 1.2 ps in benzonitrile to 260 ps in n-hexane. While back electron transfer is slow in non-polar solvents increasing back-electron transfer rates with increasing solvent polarity are observed. No rotational diffusion was observed. The measured rates for back-electron transfer were compared to rates derived from a Golden rule-type expression. Good agreement was achieved with non-polar solvents. In polar solvents, a correction using the solvent relaxation times yielded an excellent agreement between computed and observed back-electron transfer rates. Time- and frequency-resolved photoionization of the C 2A2 state of the benzyl radical The excited state lifetime of the C 2A2 state of the benzyl radical was determined as a function of excess energy. Time-dependent ion traces were fitted using a biexponential decay. At the origin of the C-state, excited state lifetimes of 400 fs and 4.5 ps were assigned to sequential internal conversion processes from the C-state to the A/B states and to the ground state. With increasing excitation, the lifetimes shorten considerably. With excitation at 301 nm the time constants are 350 fs and 2.8 ps. At 298 nm the time constants are 180 fs and 2.1 ps. In addition we observed a decay trace for a species with the composition C7H5. The carrier of the signal is fulvenallenyl. KW - Valenzgemischte Verbindungen KW - Absorptionsspektroskopie KW - Benzylradikal KW - Photoionisation KW - zeitaufgelöste Spektroskopie KW - gemischtvalente Verbindung KW - time-resolved spectroscopy KW - mixed-valence compound KW - benzyl radical Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-54032 ER -