TY - JOUR A1 - Stefanakis, Mona A1 - Bassler, Miriam C. A1 - Walczuch, Tobias R. A1 - Gerhard-Hartmann, Elena A1 - Youssef, Almoatazbellah A1 - Scherzad, Agmal A1 - Stöth, Manuel Bernd A1 - Ostertag, Edwin A1 - Hagen, Rudolf A1 - Steinke, Maria R. A1 - Hackenberg, Stephan A1 - Brecht, Marc A1 - Meyer, Till Jasper T1 - The impact of tissue preparation on salivary gland tumors investigated by Fourier-transform infrared microspectroscopy JF - Journal of Clinical Medicine N2 - Due to the wide variety of benign and malignant salivary gland tumors, classification and malignant behavior determination based on histomorphological criteria can be difficult and sometimes impossible. Spectroscopical procedures can acquire molecular biological information without destroying the tissue within the measurement processes. Since several tissue preparation procedures exist, our study investigated the impact of these preparations on the chemical composition of healthy and tumorous salivary gland tissue by Fourier-transform infrared (FTIR) microspectroscopy. Sequential tissue cross-sections were prepared from native, formalin-fixed and formalin-fixed paraffin-embedded (FFPE) tissue and analyzed. The FFPE cross-sections were dewaxed and remeasured. By using principal component analysis (PCA) combined with a discriminant analysis (DA), robust models for the distinction of sample preparations were built individually for each parotid tissue type. As a result, the PCA-DA model evaluation showed a high similarity between native and formalin-fixed tissues based on their chemical composition. Thus, formalin-fixed tissues are highly representative of the native samples and facilitate a transfer from scientific laboratory analysis into the clinical routine due to their robust nature. Furthermore, the dewaxing of the cross-sections entails the loss of molecular information. Our study successfully demonstrated how FTIR microspectroscopy can be used as a powerful tool within existing clinical workflows. KW - formalin KW - fixation KW - tissue preparation KW - salivary gland neoplasia KW - FTIR spectroscopy KW - principal component analysis KW - discriminant analysis Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-304887 SN - 2077-0383 VL - 12 IS - 2 ER - TY - JOUR A1 - Jordan, Martin C. A1 - Jäckle, Veronika A1 - Scheidt, Sebastian A1 - Eden, Lars A1 - Gilbert, Fabian A1 - Heintel, Timo M. A1 - Jansen, Hendrik A1 - Meffert, Rainer H. T1 - Ergebnisse nach Plattenstabilisierung der Symphysensprengung JF - Der Unfallchirurg N2 - Hintergrund Die Symphysensprengung mit entsprechender Diastase kann durch eine Symphysenplatte stabilisiert werden. Fragestellung Welche Beckenverletzungen werden mit einer Symphysenplatte stabilisiert und wie ist das Outcome? Material und Methoden Retrospektive Auswertung von 64 Patienten über einen Untersuchungszeitraum von 24 Monaten. Ergebnisse Es waren 56 Patienten männlich, 8 weiblich und das mittlere Alter betrug 44 Jahre (SD ± 17). Unfälle im Straßenverkehr waren der führende Grund für die Beckenverletzung. Die Verteilung nach AO-Klassifikation zeigte sich wie folgt: 14-mal B1-, 10-mal B2-, 5‑mal B3-, 23-mal C1-, 9‑mal C2- und 3‑mal C3-Verletzungen. Die Verteilung nach Young und Burgess ergab: 9‑mal APC-I-, 18-mal APC-II-, 13-mal APC-III-, 9‑mal LC-I-, 3‑mal LC-II-, 2‑mal LC-III- und 10-mal VS-Verletzungen. Der mittlere Injury Severity Score (ISS) betrug 32 und die mittlere stationäre Verweildauer 29 Tage (pos. Korrelation p ≤ 0,001). Im Verlauf war eine radiologische Implantatlockerung bei 52 Patienten nachweisbar. Therapierelevante Komplikationen gab es in 14 Fällen. Hierbei war das Implantatversagen (n = 8) der Hauptgrund für eine operative Revision. Diskussion Obwohl die radiologische Implantatlockerung häufig beobachtet wird, ist sie nur selten Grund für einen Revisionseingriff. Kommt es hingegen zum vollständigen Implantatversagen, tritt dies meist innerhalb der ersten postoperativen Wochen auf und ist revisionsbedürftig. Eine frühzeitige Abklärung durch Röntgenbildgebung sollte bei Verdacht erfolgen. N2 - Background Separation of the pubic symphysis with corresponding diastasis can be stabilized by symphyseal plating. Objective Which pelvic injuries are stabilized with symphyseal plating and what is their outcome? Material and methods A retrospective evaluation of 64 patients who underwent symphyseal plating over a period of 24 months was conducted. Results Of the patients 56 were male and 8 female with a mean age of 44 years (SD ± 17 years). The main cause of the pelvic injuries were traffic accidents. The distribution according to the AO fracture classification was 14 × B1, 10 × B2, 5 × B3, 23 × C1, 9 × C2 and 3 × C3 injuries. The distribution according to the Young and Burgess classification showed 9 × APC I, 18 × APC II, 13 × APC III, 9 × LC I, 3 × LC II, 2 × LC III and 10 × VS injuries. The mean Injury Severity Score (ISS) was 32 (SD ± 17) and the mean inpatient stay was 29 days (SD ± 16 days; positive correlation p ≤ 0.001). Radiological implant loosening occurred in 52 patients. 14 patients required treatment for severe complications. The leading reason for revision surgery was implant failure (n = 8). Conclusion These observations suggest that radiological signs of implant loosening are commonly observed but rarely the reason for revision surgery. Complete implant failures, however; occur mainly within the first postoperative weeks and require early revision. A timely clarification by additional X-ray imaging should be carried out if this is suspected. KW - Beckenring KW - Beckenfraktur KW - AO KW - Fixation KW - Trauma KW - pelvic ring KW - pelciv fracture KW - AO KW - fixation KW - trauma Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-232447 SN - 0177-5537 VL - 123 ER - TY - JOUR A1 - Fuchs, Konrad F. A1 - Heilig, Philipp A1 - McDonogh, Miriam A1 - Boelch, Sebastian A1 - Gbureck, Uwe A1 - Meffert, Rainer H. A1 - Hoelscher-Doht, Stefanie A1 - Jordan, Martin C. T1 - Cement-augmented screw fixation for calcaneal fracture treatment: a biomechanical study comparing two injectable bone substitutes JF - Journal of Orthopaedic Surgery and Research N2 - Background The role of cement-augmented screw fixation for calcaneal fracture treatment remains unclear. Therefore, this study was performed to biomechanically analyze screw osteosynthesis by reinforcement with either a calcium phosphate (CP)-based or polymethylmethacrylate (PMMA)-based injectable bone cement. Methods A calcaneal fracture (Sanders type IIA) including a central cancellous bone defect was generated in 27 synthetic bones, and the specimens were assigned to 3 groups. The first group was fixed with four screws (3.5 mm and 6.5 mm), the second group with screws and CP-based cement (Graftys (R) QuickSet; Graftys, Aix-en-Provence, France), and the third group with screws and PMMA-based cement (Traumacem (TM) V+; DePuy Synthes, Warsaw, IN, USA). Biomechanical testing was conducted to analyze peak-to-peak displacement, total displacement, and stiffness in following a standardized protocol. Results The peak-to-peak displacement under a 200-N load was not significantly different among the groups; however, peak-to-peak displacement under a 600- and 1000-N load as well as total displacement exhibited better stability in PMMA-augmented screw osteosynthesis compared to screw fixation without augmentation. The stiffness of the construct was increased by both CP- and PMMA-based cements. Conclusion Addition of an injectable bone cement to screw osteosynthesis is able to increase fixation strength in a biomechanical calcaneal fracture model with synthetic bones. In such cases, PMMA-based cements are more effective than CP-based cements because of their inherently higher compressive strength. However, whether this high strength is required in the clinical setting for early weight-bearing remains controversial, and the non-degradable properties of PMMA might cause difficulties during subsequent interventions in younger patients. KW - arthritis KW - bone KW - calcaneus KW - cement KW - fracture KW - fixation KW - osteoporosis KW - sanders KW - screw Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230336 VL - 15 ER -