TY - THES A1 - Gromova, Kira V. T1 - Visualization of the Smad direct signaling response to Bone Morphogenetic Protein 4 activation with FRET-based biosensors T1 - Visualisierung der Smad-vermittelten Signaltransduktion nach Aktivierung mit "Bone Morphogenetic Protein" 4 mittels FRET-basierter Biosensoren N2 - The Transforming Growth Factor (TGF) superfamily of cytokines and their serine/threonine kinase receptors play an important role in the regulation of cell division, differentiation, adhesion, migration, organization, and death. Smad proteins are the major intracellular signal transducers for the TGF receptor superfamily that mediate the signal from the membrane into the nucleus. Bone Morphogenetic Protein-4 (BMP-4) is a representative of the TGF superfamily, which regulates the formation of teeth, limbs and bone, and also plays a role in fracture repair. Binding of BMP-4 to its receptor stimulates phosphorylation of Smad1, which subsequently recruits Smad4. A hetero-oligomeric complex consisting of Smad1 and Smad4 then translocates into the nucleus and regulates transcription of target genes by interacting with transcription factors. Although the individual steps of the signaling cascade from the receptor to the nucleus have been identified, the exact kinetics and the rate limiting step(s) have remained elusive. Standard biochemical techniques are not suitable for resolving these issues, as they do not offer sufficiently high sensitivity and temporal resolution. In this study, advanced optical techniques were used for direct visualization of Smad signaling in live mammalian cells. Novel fluorescent biosensors were developed by fusing cyan and yellow fluorescent proteins to the signaling molecules Smad1 and Smad4. By measuring Fluorescence Resonance Energy Transfer (FRET) between the two fluorescent proteins, the kinetics of BMP/Smad signaling was unraveled. A rate-limiting delay of 2 - 5 minutes occurred between BMP receptor stimulation and Smad1 activation. A similar delay was observed in the complex formation between Smad1 and Smad4. Further experimentation indicated that the delay is dependent on the Mad homology 1 (MH1) domain of Smad1. These results give new insights into the dynamics of the BMP receptor – Smad1/4 signaling process and provide a new tool for studying Smads and for testing inhibitory drugs. N2 - Die Transforming Growth Factor" (TGF)-Superfamilie der Cytokine und ihrer Serin/Threonin-Kinase-Rezeptoren spielt eine bedeutende Rolle bei der Regulierung der Zellteilung, -differenzierung, -adhäsion, -migration, -organisation, und beim Zelltod. Die Smad-Proteine sind die wichtigsten intrazellulären Signalüberträger für die TGF-Rezeptor-Familie, da sie das Signal von der Zellmembran zum Kern übermitteln. Das ,,Bone Morphogenetic Protein4" (BMP-4) ist ein Vertreter der TGF-Familie, der die Bildung von Zähnen, Gliedmaßen und Knochen reguliert und darüber hinaus eine Rolle bei der Frakturheilung spielt. Das Binden von BMP-4 an seinen Rezeptor stimuliert die Phosphorylierung von Smad1, welches in der Folge Smad4 rekrutiert. Ein hetero-oligomerer Komplex bestehend aus Smad1 und Smad4 verlagert sich dann in den Zellkern, wo er durch Interaktion mit Transkriptionsfaktoren die Transkription von Zielgenen reguliert. Obwohl die einzelnen Schritte der Signalkaskade vom Rezeptor bis in den Zellkern bereits identifiziert wurden, blieben die Kinetik und die geschwindigkeitsbegrenzenden Schritte bisher unbekannt. Gängige biochemische Methoden eignen sich nicht um diese Fragen zu lösen, da sie nicht über ausreichende Empfindlichkeit und zeitliches Auflösungsvermögen verfügen. In der vorliegenden Arbeit wurden hochentwickelte optische Techniken angewandt, um die Smad-vermittelte Signaltransduktion direkt in lebenden Zellen sichtbar zu machen. Neue fluoreszierende Biosensoren wurden konstruiert, indem gelb- und cyan-fluoreszierende Proteine mit den Signalmoleküle Smad1 und Smad4 fusioniert wurden. Durch Messung des "Fluorescent Resonance Energy Transfer" (FRET) zwischen den zwei fluoreszierenden Proteinen konnte die Kinetik der BMP-Smad-Signalkaskade bestimmt werden. Zwischen der Stimulation des Rezeptors und der Aktivierung von Smad1 trat eine geschwindigkeitsbegrenzende Verzögerung von 2-5 Minuten auf. Eine ähnliche Verzögerung wurde bei der Bildung des Komplexes aus Smad1 und Smad4 beobachtet. Weitere Experimente zeigten, dass die Verzögerung von der Mad-Homologie-Domäne 1 (MH1) von Smad1 abhängt. Die Ergebnisse dieser Arbeit geben neue Einblicke in die Dynamik der BMP-Rezeptor-Smad1/4 Signaltransduktion und stellen neue Werkzeuge zur Untersuchung von Smads und zur Austestung inhibitorischer Wirkstoffe zur Verfügung. KW - FRET KW - Mikroskopie KW - Signaltransduktion KW - Smad KW - BMP KW - FRET KW - microscopy KW - signaling KW - Smad KW - bone morphogenetic protein KW - fluorescent protein Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-25855 ER - TY - JOUR A1 - Nanguneri, Siddharth A1 - Flottmann, Benjamin A1 - Horstmann, Heinz A1 - Heilemann, Mike A1 - Kuner, Thomas T1 - Three-Dimensional, Tomographic Super-Resolution Fluorescence Imaging of Serially Sectioned Thick Samples JF - PLoS One N2 - Three-dimensional fluorescence imaging of thick tissue samples with near-molecular resolution remains a fundamental challenge in the life sciences. To tackle this, we developed tomoSTORM, an approach combining single-molecule localization-based super-resolution microscopy with array tomography of structurally intact brain tissue. Consecutive sections organized in a ribbon were serially imaged with a lateral resolution of 28 nm and an axial resolution of 40 nm in tissue volumes of up to 50 \(\mu\)mx50\(\mu\)mx2.5\(\mu\)m. Using targeted expression of membrane bound (m)GFP and immunohistochemistry at the calyx of Held, a model synapse for central glutamatergic neurotransmission, we delineated the course of the membrane and fine-structure of mitochondria. This method allows multiplexed super-resolution imaging in large tissue volumes with a resolution three orders of magnitude better than confocal microscopy. KW - architecture KW - rat calyx KW - in-vivo KW - microscopy KW - resolution KW - proteins KW - transmission KW - ultrastructure KW - reconstruction KW - localization Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-134434 VL - 7 IS - 5 ER - TY - JOUR A1 - Grimm, Jonathan B. A1 - Klein, Teresa A1 - Kopek, Benjamin G. A1 - Shtengel, Gleb A1 - Hess, Harald F. A1 - Sauer, Markus A1 - Lavis, Luke D. T1 - Synthesis of a far-red photoactivatable silicon-containing rhodamine for super-resolution microscopy JF - Angewandte Chemie International Edition N2 - The rhodamine system is a flexible framework for building small‐molecule fluorescent probes. Changing N‐substitution patterns and replacing the xanthene oxygen with a dimethylsilicon moiety can shift the absorption and fluorescence emission maxima of rhodamine dyes to longer wavelengths. Acylation of the rhodamine nitrogen atoms forces the molecule to adopt a nonfluorescent lactone form, providing a convenient method to make fluorogenic compounds. Herein, we take advantage of all of these structural manipulations and describe a novel photoactivatable fluorophore based on a Si‐containing analogue of Q‐rhodamine. This probe is the first example of a “caged” Si‐rhodamine, exhibits higher photon counts compared to established localization microscopy dyes, and is sufficiently red‐shifted to allow multicolor imaging. The dye is a useful label for super‐resolution imaging and constitutes a new scaffold for far‐red fluorogenic molecules. KW - fluorophore KW - microscopy KW - photoactivation KW - Si-rhodamine KW - super-resolution imaging Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-191069 VL - 55 IS - 5 ER - TY - THES A1 - Kastner, Matthias J. T1 - Spectroscopic investigation of molecular adsorption and desorption from individual single-wall carbon nanotubes T1 - Spektroskopische Untersuchung von molekularer Adsorption und Desorption an einzelnen einwandigen Kohlenstoffnanoröhren N2 - Nanoelectronics is an essential technology for down-scaling beyond the limit of silicon-based electronics. Single-Wall Carbon Nanotubes (SWNT) are semiconducting components that exhibit a large variety of properties that make them usable for sensing, telecommunication, or computational tasks. Due to their high surface to volume ratio, carbon nanotubes are strongly affected by molecular adsorptions, and almost all properties depend on surface adsorption. SWNT with smaller diameters (0.7-0.9nm) show a stronger sensitivity to surface effects. An optimized synthesis route was developed to produce these nanotubes directly. They were produced with a clean surface, high quality, and large lengths of 2 μ m. The results complement previous studies on larger diameters (0.9-1.4nm). They allow performing statistically significant assumptions for a perfect nanotube, which is selected from a subset of nanotubes with good emission intensity, and high mechanical durability. The adsorption of molecules on the surface of carbon nanotubes influences the motion and binding strength of chargeseparated states in this system. To gain insight into the adsorption processes on the surface with a minimum of concurrent overlapping effects, a microscopic setup, and a measurement technique were developed. The system was estimated to exhibit excellent properties like long exciton diffusion lengths (>350nm), and big exciton sizes (8.5(5)nm), which was substantiated by a simulation. We studied the adsorption processes at the surface of Single-Wall Carbon Nanotubes for molecules in the gas phase, solvent molecules, and surfactant molecules. The experiments were all carried out on suspended individualized carbon nanotubes on a silicon wafer substrate. The experiments in the gas-phase showed that the excitonic emission energy and intensity experiences a rapid blue shift during observation. This shift was associated with the spontaneous desorption of large clusters of gaseous molecules caused by laser heat up. The measurement of this desorption was essential for creating a reference to an initially clean surface and allows us to perform a comparison with previous measurements on this topic. Furthermore, the adsorption of hydrogen on the nanotube surface at high temperatures was investigated. It was found that a new emission mode arises slightly red-shifted to the excitonic emission in these systems. The new signal is almost equally strong as the main excitonic peak and was associated with the brightening of dark excitons at sp3-defects through a K-phonon assisted pathway. The finding is useful for the direct synthesis of spintronic devices as these systems are known to act as single-photon emitters. The suspended nanotubes were further studied to estimate the effect of solvent adsorption on the excitonic states during nanotube dispersion for each nanotube individually. A significant quantum yield loss is observable for hexane and acetonitrile, while the emission intensity was found to be the strongest in toluene. The reference to a clean surface allowed us to estimate the exact influence of the dielectric environment of adsorbing solvents on the excitonic emission energy. Solvent adsorption was found to lead to an energy shift that is almost twice as high as suggested in previous studies. The amount of this energy shift, however, was comparably similar for all solvents, which suggests that the influence of the distinct dielectric constant in the outer environment less significantly influences the energy shift than previously thought. An interesting phenomenon was found when using acetonitrile as a solvent, which leads to greatly enhanced emission properties. The emission is more than twice as high as in the same air-suspended nanotubes, which suggests a process that depends on the laser intensity. In this study, it was reasonably explained how an energy down-conversion is possible through the coupling of the excitonic states with solvent vibrations. The strength of this coupling, however, also suggests adsorptions to the inside of the tubular nanotube structure leading to a coupled vibration of linear acetonitrile molecules that are adsorbed to the inner surface. The findings are important for the field of nanofluidics and provide an excellent system for efficient energy down-conversion in the transmission window of biological tissue. Having separated the pure effect of solvent adsorption allowed us to study the undisturbed molecular adsorption of polymers in these systems. The addition of polyfluorene polymer leads to a slow but stepwise intensity increase. The intensity increase is overlapping with a concurrent process that leads to an intensity decrease. Unfortunately, observing the stepwise process has a low spacial resolution of only 100-250nm, which is in the range of the exciton diffusion length in these systems and hinders detailed analysis. The two competing and overlapping processes processes are considered to originate from slow π-stacking and fast side-chain binding. Insights into this process are essential for selecting suitably formed polymers. However, the findings also emphasize the importance of solvent selection during nanotube dispersion since solvent effects were proven to be far more critical on the quantum yield in these systems. These measurements can shed light on the ongoing debate on polymers adsorption during nanotube individualization and allow us to direct the discussion more towards the selection of suitable solvents. This work provides fundamental insights into the adsorption of various molecules on the surface of individually observed suspended Single-Wall Carbon Nanotubes. It allows observing the adsorption of individual molecules below the optical limit in the solid, liquid, and gas phases. Nanotubes are able to act as sensing material for detecting changes in their direct surrounding. These fundamental findings are also crucial for increasing the quantum yield of solvent-dispersed nanotubes. They can provide better light-harvesting systems for microscopy in biological tissue and set the base for a more efficient telecommunication infrastructure with nano-scale spintronics devices and lasing components. The newly discovered solvent alignment in the nanotube surrounding can potentially also be used for supercapacitors that are needed for caching the calculation results in computational devices that use polymer wrapped nanotubes as transistors. Although fundamental, these studies develop a strategy to enlighten this room that is barely only visible at the bottom of the nano-scale. N2 - Nanoelektronik ist eine wichtige Technologie um das Größen-Limit gegenwärtiger Silizium-basierter Technologie zu überwinden. Einwandige Kohlenstoffnanoröhren sind halbleitende Moleküle, die eine Reihe von Eigenschaften dafür zur Verfügung stellen. Sie sind einsetzbar als Sensoren, in der Fernmeldetechnik und für elektronische Rechenoperationen. Aufgrund ihres hohen Verhältnisses von Oberfläche zu Volumen werden nahezu alle Eigenschaften von Kohlenstoffnanoröhren stark von Adsorption beeinflusst. Einwandige Kohlenstoffnanoröhren mit kleineren Durchmessern (0.7-0.9nm) zeigen einen stärkeren Einfluss auf Phänomene, die an der Oberfläche auftreten. Um speziell diese Nanoröhren genauer zu untersuchen wurde eine Synthese Strategie entwickelt, die Nanoröhren mit hoher Qualität und Länge herstellen kann und dabei eine saubere Oberfläche gewährleisten ohne ihre Emissions-Stärke durch Bündelung zu verlieren. Die erhaltenen Ergebnisse unterstützen Studien aus der Literatur, die zumeist an Röhren mit größeren Durchmessern durchgeführt wurden. Die Größe des Datensatzes erlaubt es, Nanoröhren mit perfekten Emissions-Eigenschaften und großer mechanischer Stabilität auszuwählen. Adsorptionen beeinflussen die Bewegung und Bindungs-Stärke der Excitonen, da sie ein Coulomb Potential an der Außenseite der Röhre ausbilden. Um die Adsorptionsprozess an der Oberfläche mit minimalen konkurrierenden Effekten zu untersuchen, wurde ein spezielles mikroskopisches Setup gewählt und eine Messmethode entwickelt um dieses System zu untersuchen. Das System wurde mit Hilfe von Bildern und Spektren charakterisiert. Über eine Simulation wurde außerdem gezeigt dass die untersuchten Nanoröhren große Diffusionslängen (>350nm) und Exciton Größen (<8.5nm) besitzen müssen. Der Adsorptions Prozess an Kohlenstoffnanoröhren wurde sowohl mit Molekülen in der Gas-Phase untersucht, also auch in Lösungsmitteln und mit Feststoffen. Alle Experimente wurde dabei an frei hängenden Röhren durchgeführt, die auf einem Silizium Wafer Substrat aufgebracht wurden. Die Experimente in der Gas Phase zeigten, dass die excitonische Emissions-Energie eine instantane und schnelle Blauverschiebung erfährt wenn die Nanoröhren mit einem Laser angeregt werden. Diese Verschiebung wurde auf die Desorption von Oberflächenverunreinigungen zurückgeführt, die an Luft inhärent die Messung beeinflussen. Durch die Annahme, nach der Untersuchung eine reine Oberfläche zu erhalten, konnte die Referenz der Vakkum-Emission erstellt werden, was es ermöglicht, den Einfluss der dielektrischen Umgebung genauer zu bestimmen. In einem weitern Experiment wurde die Adsorption von Wasserstoff getestet. In diesen Systemen bildet sich durch die Ausbildung von sp 3 -Defekten eine neue Emissionsbande aus. Solche Emissionen werden derzeit für die Anwendung als Einzelphotonenemitter diskutiert. Die hier vorgestellte Methode erlaubt die direkte Synthese solcher Systeme im CVD Ofen. Die frei hängenden Nanoröhren wurden weiter analysiert um den Effekt des Lösungsmittels auf die Emission detailiert zu untersuchen. Es wurde gezeigt, dass in Hexan und Acetonitril ein signifikant hoher Quantenausbeute-Verlust zu beobachten ist. Toluol hingegen zeigte sich hier am Besten. Die Energie-Verschiebungen waren insignifikant unterschiedlich zwischen den Lösungsmitteln. Ein Spezialfall war bei Acetonitril zu beobachten, in dem sich über den Zeitraum von 24h eine starke Emission herausbildet, die auf eine Kopplung mit Lösungsmittel-Schwingungen zurückgeführt wird. Die Stärke dieser Emission erlaubt die Vermutung, dass es sich um eine gekoppelte Schwingung von linear orientiertem Acetonitril in der Nanoröhre handelt. Eine solch starke Emission könnte zu Anwendungen in Zell-Gewebe führen, da weder Anregung noch Emission sich im Fenster der Blut- und Wasserabsorption befindet. Durch die eindeutige Identifizierung von Lösungsmitteleffekten auf die Dispergierung von Kohlenstoffnanoröhren war es möglich, den Prozess der Anlagerung von Polyfluorene Polymeren direkt zu beobachten. Das Hinzufügen von Polymer zur Lösung führt zu einem schrittweisen reversiblen Anstieg der Emissions Intensität. Dieser Anstieg wird von einem gleichzeitigen irreversiblen schrittweisen Abfall der Emissionsintensität begleitet. Leider ist das System nur geeignet, Adsorptionen bis maximal 100nm Länge aufzulösen. Eine detaillierte Analyse ist daher schwer. Trotzdem wird vermutet, dass es sich bei dem langsamen Prozess um das Ausbilden von π -Stapeln handelt, wobei der schnelle Prozess mit der nicht-kovalenten Bindung der Polymer-Seitenketten an die Oberfläche assoziiert wird. Obwohl über die eigentliche Bindung des Polymers nur Vermutungen angestellt werden können, so wirft die Untersuchung doch einen Fokus auf die Wahl des Lösungsmittels, da diese Entscheidung einen viel größeren Effekt verursacht, als die Bindung des Polymers selbst. Diese Arbeit stellt fundamentale Betrachtungen zur Adsorption von verschiedenen Molekülen an Kohlenstoffnanoröhren auf. Die Betrachtungen wurden mit festen, flüssigen und gasförmigen Molekülen durchgeführt. Die Ergebnisse zeigen, dass Nanoröhren geeignet sind, als Molekül-Sensoren verwendet zu werden, da sie stark auf Änderungen in ihrer Umgebung reagieren können. Weiterhin wurden Lösungsmittel und Eigenschaften aufgezeigt, die die Quanteneffizienz signifikant beeinflussen. Eine Anwendung in der biologischen Mikroskopie ist denkbar, genauso wie für eine effizientere und sicherere Fernmeldeinfrastruktur. Weiterhin wurden Wege aufgezeigt, Super-Kondensatoren auf Nanorohr-Basis zu bauen, die als Anwendung in einem Kohlenstoffnanorohr-basierenden Computer von Interesse sein könnten. Obwohl die Erkenntnisse fundamental sind, zeigen diese Studien, dass es mit bestimmten Tricks möglich ist, den Raum am unteren Ende der Nanometerskala zu erforschen und zu entdecken. KW - Kohlenstoff-Nanoröhre KW - Einwandige Kohlenstoff-Nanoröhre KW - Adsorption KW - Chemisorption KW - Physisorption KW - nanotube KW - microscopy KW - adsorption Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-211755 ER - TY - JOUR A1 - Winter, Patrick M. A1 - Andelovic, Kristina A1 - Kampf, Thomas A1 - Hansmann, Jan A1 - Jakob, Peter Michael A1 - Bauer, Wolfgang Rudolf A1 - Zernecke, Alma A1 - Herold, Volker T1 - Simultaneous measurements of 3D wall shear stress and pulse wave velocity in the murine aortic arch JF - Journal of Cardiovascular Magnetic Resonance N2 - Purpose Wall shear stress (WSS) and pulse wave velocity (PWV) are important parameters to characterize blood flow in the vessel wall. Their quantification with flow-sensitive phase-contrast (PC) cardiovascular magnetic resonance (CMR), however, is time-consuming. Furthermore, the measurement of WSS requires high spatial resolution, whereas high temporal resolution is necessary for PWV measurements. For these reasons, PWV and WSS are challenging to measure in one CMR session, making it difficult to directly compare these parameters. By using a retrospective approach with a flexible reconstruction framework, we here aimed to simultaneously assess both PWV and WSS in the murine aortic arch from the same 4D flow measurement. Methods Flow was measured in the aortic arch of 18-week-old wildtype (n = 5) and ApoE\(^{−/−}\) mice (n = 5) with a self-navigated radial 4D-PC-CMR sequence. Retrospective data analysis was used to reconstruct the same dataset either at low spatial and high temporal resolution (PWV analysis) or high spatial and low temporal resolution (WSS analysis). To assess WSS, the aortic lumen was labeled by semi-automatically segmenting the reconstruction with high spatial resolution. WSS was determined from the spatial velocity gradients at the lumen surface. For calculation of the PWV, segmentation data was interpolated along the temporal dimension. Subsequently, PWV was quantified from the through-plane flow data using the multiple-points transit-time method. Reconstructions with varying frame rates and spatial resolutions were performed to investigate the influence of spatiotemporal resolution on the PWV and WSS quantification. Results 4D flow measurements were conducted in an acquisition time of only 35 min. Increased peak flow and peak WSS values and lower errors in PWV estimation were observed in the reconstructions with high temporal resolution. Aortic PWV was significantly increased in ApoE\(^{−/−}\) mice compared to the control group (1.7 ± 0.2 versus 2.6 ± 0.2 m/s, p < 0.001). Mean WSS magnitude values averaged over the aortic arch were (1.17 ± 0.07) N/m\(^2\) in wildtype mice and (1.27 ± 0.10) N/m\(^2\) in ApoE\(^{−/−}\) mice. Conclusion The post processing algorithm using the flexible reconstruction framework developed in this study permitted quantification of global PWV and 3D-WSS in a single acquisition. The possibility to assess both parameters in only 35 min will markedly improve the analyses and information content of in vivo measurements. KW - 4D flow KW - pulse wave velocity KW - wall shear stress KW - radial KW - self-navigation KW - mouse KW - aortic arch KW - atherosclerosis KW - mice KW - flow KW - plaque KW - CMR KW - quantification KW - microscopy Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-259152 VL - 23 IS - 1 ER - TY - THES A1 - Schöppler, Friedrich Eugen T1 - Photolumineszenzmikroskopie und-spektroskopie halbleitender Kohlenstoffnanoröhren T1 - Photoluminescence microscopy and spectroscopy of semiconducting nanotubes N2 - Im Rahmen dieser Dissertation wurden optische Eigenschaften von halbleitenden, einwandigen Kohlenstoffnanoröhren (SWNTs) der (6,5)-Chiralität untersucht. Dies gelang durch Ensemblemessungen aber vor allem durch den Aufbau eines Mikroskops zur Messung an einzelnen SWNTs. Dieses Einzel- SWNT-Mikroskop ermöglichte nebst „normaler“ Bildgebung durch Sammlung und Abbildung der nahinfraroten Photolumineszenz (PL) der (6,5)-SWNTs auch die spektral- und zeitaufgelöste Untersuchung der PL. Durch Verwendung von Dichtegradientenultrazentrifugation (DGU) zur chiralen Aufreinigung des SWNT-Rohmaterials konnten alle Messungen unter Minimierung des störenden Einflusses von Aggregaten oder SWNTs anderer Chiralität durchgeführt werden. Untersucht und bestimmt wurde der Absorptionsquerschnitt und die Exzitonengröße, die PL-Eigenschaften aggregierter SWNTs und der Einfluß der Permittivität auf die PL einzelner SWNTs. N2 - Within the course of this work fundamental optical properties of semiconducting single-walled carbon nanotubes (SWNTs) of the (6,5)-chirality were examined by utilizing ensemble measurements and in particular a home-built microscope setup for measurements of individual SWNTs. This single-SWNTmicroscope allowed for „standard“ imaging of the near infrared photoluminescence (PL) signal of the (6,5)-SWNTs as well as for spectrally and timeresolved PL measurements. Facilitating density gradient ultracentrifugation (DGU) for chiral enrichment of the SWNT soot, all measurements were carried out with minimum influence of aggregates or minority species of other SWNT chiralities. The absorption cross section, the exciton size, PL-features of aggregated SWNTs and the influence of permittivity on SWNT-PL have been investigated. KW - Mikroskopie KW - Photolumineszenz KW - Photolumineszenzspektroskopie KW - Kohlenstoff-Nanoröhre KW - Halbleiter KW - Spektroskopie KW - NIR-Spektroskopie KW - Lebensdauer KW - Laserinduzierte Fluoreszenz KW - Aggregation KW - Exziton KW - Dielektrizitätszahl KW - microscopy KW - spectroscopy KW - carbon nanotubes KW - fluorescence Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-73329 ER - TY - THES A1 - Purea, Edmund Armin T1 - New Methods and Applications in Nuclear Magnetic Resonance Microscopy using small RF Coils T1 - Neue Methoden und Anwendungen kleiner HF-Spulen in der NMR-Mikroskopie N2 - Nuclear magnetic resonance (NMR) imaging is a well-established imaging technique. If the achieved spatial resolution is below 100 um, it is usually denoted as magnetic resonance microscopy (MRM). The spatial resolution limit is on the order of a few um. As a downside, high resolution imaging is usually time-consuming and technological requirements are very sumptuous. Furthermore, miniaturization of the radiofrequency (RF) coil leading to a so-called microcoil is necessary; it also brings along detrimental effects. Therefore, there is a high potential for optimizing present MRM methods. Hence it is the aim of this work to improve and further develop present methods in MRM with focus on the RF coil and to apply those methods on new biological applications. All experiments were conducted on a Bruker 17.6 T system with a maximum gradient strength of 1 T/m and four RF receiver channels. Minimizing the RF coil dimensions, leads to increased artefacts due to differences in magnetic susceptibility of the coil wire and surrounding air. Susceptibility matching by immersing the coil in FC-43 is the most common approach that fulfills the requirements of most applications. However, hardly any alternatives are known for cases where usage of FC-43 is not feasible due to its specific disadvantages. Two alternative substances (bromotricholoromethane and Fomblin Y25) were presented and their usability was checked by susceptibility determination and demonstration experiments after shimming under practical conditions. In a typical MRM microcoil experiment, the sample volume is significantly smaller than the maximum volume usable for imaging. This mismatch has been optimized in order to increase the experiment efficiency by increasing the number of probe coils and samples used. A four-channel probehead consisting of four individual solenoid coils suited for cellular imaging of Xenopus laevis oocytes was designed, allowing simultaneous acquisition from four samples. All coils were well isolated and allowed quantitative image acquisition with the same spatial resolution as in single coil operation. This method has also been applied in other studies for increased efficiency: using X. laevis oocytes as a single cell model, the effect of chemical fixation on intracellular NMR relaxation times T1 and T2 and on diffusion was studied for the first time. Significant reduction of relaxation times was found in all cell compartments; after reimmersion in buffer, values return close to the initial values, but there were small but statistically significant differences due to residual formaldehyde. Embryos of the same species have been studied morphologically in different developmental stages. Wild type embryos were compared to embryos that had experienced variations in protein levels of chromosomal proteins HMGN and H1A. Significant differences were found between wild type and HMGN-modified embryos, while no difference was observed between wild type and H1-modified embryos. These results were concordant with results obtained from light microscopy and histology. The technique of molecular imaging was also performed on X. laevis embryos. Commercially available antibodies coupled to ultrasmall superparamagnetic iron oxide (USPIO) dextrane coated particles (MACS) served as a specific probe detectable by MRM, the aim being the detection of tissue specific contrast variations. Initially, the relaxivity of MACS was studied and compared to Resovist and VSOP particles. The iron concentration was determined quantitatively by using a general theoretical approach and results were compared to values obtained from mass spectroscopy. After incubation with MACS antibodies, intraembryonal relaxation times were determined in different regions of the embryo. These values allowed determination of local iron oxide particle concentrations, and specific binding could be distinguished from unspecific binding. Although applications in this work were focused on X. laevis oocytes and embryos, 3D-imaging on a beewolf head was also carried out in order to visualize the postpharyngeal gland. Additionally, an isolated beewolf antenna was imaged with a spatial resolution of (8 um)^3 for depiction of the antennal glands by using a microcoil that was specially designed for this sample. The experiments carried out in this work show that commercially available MRM systems can be significantly optimized by using small sample-adapted RF coils and by parallel operation of multiple coils, by which the sample throughput and thus time-efficiency is increased. With this optimized setup, practical use was demonstrated in a number of new biological applications. N2 - Bildgebung mittels magnetischer Kernresonanz (NMR) ist eine etablierte Methode. Liegt die erreichte Ortsauflösung unter 100 um, wird sie allgemein als Magnetresonanz-Mikroskopie (MRM) bezeichnet. Die Untergrenze der Auflösung liegt in der Größenordnung weniger um. Da höchstaufgelöste Bildgebung meist sehr zeitintensiv ist, kostspielige Anforderungen an die zugrunde liegende Technologie setzt und zudem durch die notwendige Verkleinerung der Hochfrequenz (HF)-Spule auf sogenannte microcoils und Erhöhung der Bildauflösung auch nachteilige Effekte zunehmen, besteht viel Optimierungsbedarf bei bestehenden MRM-Methoden. Das Ziel dieser Arbeit war daher die Verbesserung und Weiterentwicklung bestehender Methoden der MRM mit besonderem Augenmerk auf die HF-Spule und ihre Anwendung auf neue biologische Fragestellungen. Alle Experimente wurden an einem Bruker 17.6T System mit einer maximalen Gradientenstärke von 1T/m und vier HF-Empfangskanälen durchgeführt. Die Miniaturisierung der HF-Spule führt zu Bildverzerrungen aufgrund des Unterschieds in magnetischer Suszeptibilität zwischen Luft und Spulendraht. Der übliche Ansatz der Suszeptibilitätsanpassung mit FC-43 ist für die meisten Anwendungen ausreichend, jedoch gibt es kaum bekannte Alternativen für den Fall, dass die Nachteile von FC-43 eine Verwendung verhindern. Es wurden zwei neue Substanzen (Bromtrichlormethan sowie Fomblin Y25) vorgestellt und ihre Verwendbarkeit mittels Suszeptibilitätsmessung und experimentellen Shim-Ergebnissen im praktischen Einsatz geprüft. Bei üblichen MRM-Experimenten mit ’microcoils’ ist das Probenvolumen deutlich kleiner als das maximal für Bildgebung zur Verfügung stehende Volumen. Dieses Ungleichgewicht wurde ausgenutzt, um die Effizienz von Mikroskopie-Experimenten durch parallelen Einsatz mehrerer ’microcoils’ zu erhöhen. Ein Probenkopf mit vier entkoppelten Solenoidspulen wurde für zelluläre Bildgebung an Xenopus laevis (Krallenfrosch)-Oozyten konstruiert. Ohne Auflösungsverlust konnten damit vier Proben zeitgleich quantitativ untersucht werden. Diese Methode wurde auch in weiteren Studien zur Steigerung der Effizienz eingesetzt: Am Modell einzelner Zellen (X. laevis-Oozyten) wurde die Auswirkung chemischer Fixierung auf NMR-Relaxationszeiten (T1, T2) sowie Diffusion erstmals intrazellulär untersucht. Es konnten erhebliche Verkürzungen der Relaxationszeiten in allen Zellkompartimenten festgestellt werden, die nach Spülung mit Pufferlösung bis auf geringe, statistisch signifikante Abweichungen bedingt durch verbleibendes Formaldehyd auf die Ausgangswerte der nichtfixierten Zelle zurückkehrten. In einem weiteren Projekt wurden Embryonen derselben Spezies in verschiedenen Entwicklungsstadien morphologisch untersucht. Wildtyp-Embryonen wurden mit Embryonen verglichen, deren natürlicher Gehalt an chromosomalen Proteinen HMGN und H1A verändert wurden. Signifikante Unterschiede zwischen Wildtyp und HMGN-veränderten Embryonen konnten festgestellt werden, während sich kein Unterschied zu H1A-veränderten Embryonen zeigte. Lichtmikroskopie und Histologie lieferten damit übereinstimmende Ergebnisse. Ebenfalls an Xenopus-Embryonen wurde die Technik der molekularen Bildgebung eingesetzt. Ziel war es, mit kommerziell erhältlichen Antikörpern, die an superparamagnetische Eisenoxidpartikel mit einer Größe von wenigen nm (USPIO) mit Dextranhülle gekoppelt sind (MACS), gewebespezifische Kontraständerungen zu erhalten. Zunächst wurde die Relaxivität von MACS untersucht und mit Resovist- sowie VSOP-Partikeln verglichen. Anschließend wurde die Eisenkonzentration quantitativ unter Zuhilfenahme eines allgemeinen theoretischen Modells bestimmt und mit Ergebnissen verglichen, die massenspektroskopisch gewonnen wurden. Nach Inkubation mit MACS wurden Relaxationszeiten intraembryonal in verschiedenen Regionen gemessen. Daraus wurden Konzentrationen von Eisenoxid-Partikeln berechnet; zusätzlich konnte zwischen spezifischer und unspezifischer Bindung differenziert werden. Obwohl der Anwendungsschwerpunkt dieser Arbeit auf der Bildgebung an X. laevis- Oozyten und Embryonen lag, wurde auch Bildgebung am Kopf eines Bienenwolfs zur 3D-Darstellung der Postpharyngealdrüse durchgeführt. Zusätzlich wurde mit einer speziell auf das Untersuchungsobjekt angepassten ’microcoil’ eine isolierte Bienenwolfantenne mit einer Auflösung von (8 um)^3 untersucht; Ziel war die Darstellung der Antennaldrüsen. Die durchgeführten Projekte zeigen, dass bei kommerziell erhältlichen MRM-Systemen deutliches Optimierungspotential existiert: zum einen durch verkleinerte und probenangepasste HF-Spulen, zum anderen durch die Parallelisierung mehrerer Spulen, wodurch der Probendurchsatz und damit die Zeiteffizienz gesteigert werden kann. Mit diesem optimierten Aufbau konnte anschließend die Nutzbarkeit der MRM bei neuen biologischen Anwendungen gezeigt werden. KW - Magnetische Resonanz KW - NMR-Bildgebung KW - Glatter Krallenfrosch KW - Bienenwolf KW - NMR-Mikroskopie KW - Simultanbildgebung KW - MRI KW - magnetic resonance KW - imaging KW - microscopy Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-31066 ER - TY - THES A1 - Haddad, Daniel T1 - Hochfeld 1H-NMR-Mikroskopie zur biophysikalischen Grundlagenforschung T1 - High Field 1H-NMR-Microscopy for Basic Biophysical Research N2 - Dank der mit modernen NMR-Spektrometern (Kernspintomographen) routinemäßig realisierbaren isotropen räumlichen Auflösungen von wenigen Mikrometern, ergeben sich für die 1H NMR-Mikroskopie zahlreiche neue Anwendungsgebiete. Allerdings sind die Möglichkeiten und Grenzen der NMR-Mikroskopie bezüglich ihrer praktischen Anwendbarkeit bisher nur wenig untersucht worden. Die vorliegende Arbeit ist im Bereich der biophysikalischen Grundlagenforschung angesiedelt und soll die praktische Anwendbarkeit der NMR-Mikroskopie auf neuen medizinischen und biologischen Anwendungsgebieten anhand von ausgewählten Beispielen aus diesen Bereichen demonstrieren. Die einzelnen Projekte besitzen deswegen immer auch den Charakter von Machbarkeitsstudien, die aufzeigen sollen, welche Möglichkeiten und Vorteile die NMR-Mikroskopie im Vergleich zu etablierten Untersuchungsmethoden bietet. Im Detail wurden unterschiedliche lebende und fixierte biologische Proben mittels NMR-Mikroskopie zerstörungsfrei und räumlich hochaufgelöst dargestellt. Dabei variierte die spezielle Zielsetzung von der Visualisierung der Invasion eines Tumorsphäroiden in ein Zellaggregat anhand von T2-Parameterkarten (Zeitkonstante der Spin-Spin-Relaxation) über die dreidimensionale Darstellung des Gehirns der Honigbiene in der intakten Kopfkapsel bis hin zur nicht-invassiven Abbildung der Anatomie prenataler Delphine. Für alle durchgeführten Projekte war der nicht-invasive Charakter der NMR-Experimente von entscheidender Bedeutung. Die zu beobachtende Tumorinvasion durfte nicht durch die Messung beeinflusst werden, das Bienengehirn sollte möglichst naturgetreu abgebildet werden, und die untersuchten Delphine sind seltene Museumsstücke, die nicht zerstört werden durften. Die verschiedenen Proben wurden mit der jeweils bestmöglichen räumlichen Auflösung visualisiert, die sich entweder durch das minimal nötige Signal-zu-Rausch-Verhältnis (SNR) oder durch die zur Verfügung stehende Messzeit ergab. Um einzelne feine Strukturen in den Bildern auflösen zu können, mussten sowohl das SNR, als auch das Kontrast-zu-Rausch-Verhältnis optimiert werden. Die Messungen wurden an Hochfeld-NMR-Spektrometern bei 500 und 750 MHz durchgeführt, um das für die hohe Auflösung notwendige SNR zu gewährleisten. Mit den Experimenten konnten zahlreiche Fragen bezüglich mikroskopischer Details der verschiedenen untersuchten Proben nicht-invasiv beantworten werden. Gleichzeitig führten sie zu neuen interessanten Fragestellungen bezüglich der NMR-Mikroskopie an fixierten Proben. Darüber hinaus konnte die praktische Anwendbarkeit der NMR-Mikroskopie als Alternative bzw. Ergänzung zu herkömmlichen Untersuchungsmethoden wie der konfokalen Lasermikroskopie bei der Visualisierung des Bienengehirns und der konventionellen Histologie bei der Untersuchung der Anatomie der prenatalen Delphine demonstriert werden. Durch die Untersuchung der speziellen Vorteile und der Grenzen der Anwendung der NMR-Mikroskopie gegenüber den herkömmlichen Untersuchungsmethoden konnte konkret der praktische Nutzen ihres Einsatzes aufgezeigt und Ergebnisse erzielt werden, die sonst nicht erzielbar wären. Gerade der Einsatz der NMR-Mikroskopie in Form der NMR-Histologie stellt einen vielversprechenden Weg zur Etablierung der NMR-Mikroskopie als Routineuntersuchungsmethode dar. Als ebenso erfolgreich hat sich die Anwendung der NMR-Mikroskopie als Untersuchungsmethode bei der Beobachtung der Tumorinvasion erwiesen, so dass sie auch in der medizinischen in-vitro Forschung und Therapiesimulation als sinnvolle Alternative zu den vorhandenen Methoden angesehen werden kann. Anhand der ausgewählten Anwendungsbeispiele ist es in dieser Arbeit somit gelungen, neue, konkrete Einsatzmöglichkeiten für die NMR-Mikroskopie zu eröffnen und ihre praktische Anwendbarkeit als Untersuchungsmethode für Fragestellungen im Bereich der medizinischen in-vitro Forschung und verschiedener neuro- und entwicklungsbiologischer Bereiche zu demonstrieren. N2 - With modern MR-spectrometers it is possible to achieve isotropic spatial resolutions in the range of only a few microns. Thus, several new fields of application for 1H-MR-Microscopy are being developed. Still, the practical possibilities and limitations of this technique have only been determined rarely. This work has a biophysical background and uses different examples to demonstrate the practical applicability of NMR-Microscopy in the medical and biological sector. Therefore, the different projects are feasibility studies which are used to compare the possibilities and advantages of NMR-Microscopy with other, established examination techniques. In detail, using MR-Microscopy, different living and fixed biological samples have been visualized non-invasively with high spatial resolution. The specific purpose of the studies ranged from the visualization of the invasion of tumor-spheroids into cell aggregates using T2 parameter maps (time constant of the spin-spin relaxation) to the three-dimensional display of the honey bee brain in the intact head capsule and the non-invasive visualization of the anatomy of prenatal dolphins. For all these projects, the non-invasive character of MR-experiments was of utmost importance. The tumor invasion was not to be disturbed by the measurements, the bee brain should be visualized as close to its true natural shape as possible and the examined dolphins represent rare museum specimens which should not be destroyed. The different samples were all imaged with the best possible spatial resolution which was either limited by the necessary signal-to-noise ratio (SNR) or the available scan time. In order to resolve single details and fine structures in the images, it was necessary to optimize the SNR as well as the contrast-to-noise ratio. To guarantee the necessary SNR, the measurements were performed on high field MR-spectrometers with resonance frequencies of 500 and 750 MHz. Numerous questions about microscopic details of the examined samples could be answered non-invasively with the experiments performed. At the same time, the experiments led to new interesting questions about MR-Microscopy on fixed samples. Furthermore, the practical applicability of MR-Microscopy as an alternative or a supplement to conventional examination methods could be demonstrated. Here, these methods were confocal laser microscopy in the case of the honey bee brain and conventional histology in the case of the prenatal dolphins. By investigating the specific advantages and limitations of MR-Microscopy in these cases, it was possible to demonstrate the practical value of its application and to obtain results which would otherwise have been impossible. Especially the use of MR-Microscopy as MR-Histology is a promising application which will help to establish MR-Microscopy as a routine examination method. Since the tumor invasion process could also be observed very successfully using MR-Microscopy, this technique can as well be considered as a valuable tool for medical in-vitro research and therapy simulation and thus an alternative to existing methods. In summary, with the examples chosen in this work, it was possible to find new applications for MR-Microscopy and to demonstrate the practical applicability of this method in the fields of medical in-vitro research as well as neurological and developmental biology. KW - NMR-Spektroskopie KW - NMR-Bildgebung KW - Hochauflösendes Verfahren KW - NMR KW - Magnetresonanztomographie KW - Kernspintomographie KW - Mikroskopie KW - Bildgebung KW - MRI KW - magnetic resonance KW - imaging KW - microscopy Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12449 ER - TY - THES A1 - Köhler, Sascha T1 - Entwicklung hochaufgelöster NMR-Methoden zur morphologischen und funktionellen Charakterisierung des Herzmuskels T1 - Development of high resolution NMR techniques for morphological and functional characterization of heart muscle N2 - Das Ziel der vorliegenden Arbeit ist es, neue Messverfahren zu entwickeln, die eine umfassende Charakterisierung des Herzmuskels ermöglichen. Sowohl die Morphologie als auch die Funktion und der Gefäßstatus wurden am intakten und am krankhaft veränderten isolierten Herzmuskel der Ratte mit NMR-Mikroskopietechniken untersucht. N2 - The goal of the present work is the development of new NMR techniques, which can be used for a broad characterization of the heart muscle. The morphology as well as the function and the status of coronary arteries was investigated in intact and in chronic infarcted hearts. KW - Herzfunktionsdiagnostik KW - NMR-Bildgebung KW - NMR KW - Bildgebung KW - Mikroskopie KW - Herz KW - Muskelfaser KW - NMR KW - imaging KW - microscopy KW - heart KW - muscle fiber Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-9060 ER - TY - JOUR A1 - Sessi, Paolo A1 - Silkin, Vyacheslav M. A1 - Nechaev, Ilya A. A1 - Bathon, Thomas A1 - El-Kareh, Lydia A1 - Chulkov, Evgueni V. A1 - Echenique, Pedro M. A1 - Bode, Matthias T1 - Direct observation of many-body charge density oscillations in a two-dimensional electron gas JF - Nature Communications N2 - Quantum interference is a striking manifestation of one of the basic concepts of quantum mechanics: the particle-wave duality. A spectacular visualization of this effect is the standing wave pattern produced by elastic scattering of surface electrons around defects, which corresponds to a modulation of the electronic local density of states and can be imaged using a scanning tunnelling microscope. To date, quantum-interference measurements were mainly interpreted in terms of interfering electrons or holes of the underlying band-structure description. Here, by imaging energy-dependent standing-wave patterns at noble metal surfaces, we reveal, in addition to the conventional surface-state band, the existence of an 'anomalous' energy band with a well-defined dispersion. Its origin is explained by the presence of a satellite in the structure of the many-body spectral function, which is related to the acoustic surface plasmon. Visualizing the corresponding charge oscillations provides thus direct access to many-body interactions at the atomic scale. KW - scanning tunneling spectroscopy KW - acoustic surface plasmon KW - metal surfaces KW - Cu(111) KW - excitations KW - microscopy KW - local density KW - standing wave formation KW - states KW - steps Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-145246 VL - 6 IS - 8691 ER -