TY - THES A1 - Ames, Christopher T1 - Molecular Beam Epitaxy of 2D and 3D HgTe, a Topological Insulator T1 - Molekularstrahlepitaxie von 2D und 3D HgTe, ein topologischer Isolator N2 - In the present thesis the MBE growth and sample characterization of HgTe structures is investigated and discussed. Due to the first experimental discovery of the quantum Spin Hall effect (QSHE) in HgTe quantum wells, this material system attains a huge interest in the spintronics society. Because of the long history of growing Hg-based heterostructures here at the Experimentelle Physik III in Würzburg, there are very good requirements to analyze this material system more precisely and in new directions. Since in former days only doped HgTe quantum wells were grown, this thesis deals with the MBE growth in the (001) direction of undoped HgTe quantum wells, surface located quantum wells and three dimensional bulk layers. All Hg-based layers were grown on CdTe substrates which generate strain in the layer stack and provide therefore new physical effects. In the same time, the (001) CdTe growth was investigated on n-doped (001) GaAs:Si because the Japanese supplier of CdTe substrates had a supply bottleneck due to the Tohoku earthquake and its aftermath in 2011. After a short introduction of the material system, the experimental techniques were demonstrated and explained explicitly. After that, the experimental part of this thesis is displayed. So, the investigation of the (001) CdTe growth on (001) GaAs:Si is discussed in chapter 4. Firstly, the surface preparation of GaAs:Si by oxide desorption is explored and analyzed. Here, rapid thermal desorption of the GaAs oxide with following cool down in Zn atmosphere provides the best results for the CdTe due to small holes at the surface, while e.g. an atomic flat GaAs buffer deteriorates the CdTe growth quality. The following ZnTe layer supplies the (001) growth direction of the CdTe and exhibits best end results of the CdTe for 30 seconds growth time at a flux ratio of Zn/Te ~ 1/1.2. Without this ZnTe layer, CdTe will grow in the (111) direction. However, the main investigation is here the optimization of the MBE growth of CdTe. The substrate temperature, Cd/Te flux ratio and the growth time has to be adjusted systematically. Therefore, a complex growth process is developed and established. This optimized CdTe growth process results in a RMS roughness of around 2.5 nm and a FWHM value of the HRXRD w-scan of 150 arcsec. Compared to the literature, there is no lower FWHM value traceable for this growth direction. Furthermore, etch pit density measurements show that the surface crystallinity is matchable with the commercial CdTe substrates (around 1x10^4 cm^(-2)). However, this whole process is not completely perfect and offers still room for improvements. The growth of undoped HgTe quantum wells was also a new direction in research in contrast to the previous n-doped grown HgTe quantum wells. Here in chapter 5, the goal of very low carrier densities was achieved and therefore it is now possible to do transport experiments in the n - and p - region by tuning the gate voltage. To achieve this high sample quality, very precise growth of symmetric HgTe QWs and their HRXRD characterization is examined. Here, the quantum well thickness can now determined accurate to under 0.3 nm. Furthermore, the transport analysis of different quantum well thicknesses shows that the carrier density and mobility increase with rising HgTe layer thickness. However, it is found out that the band gap of the HgTe QW closes indirectly at a thickness of 11.6 nm. This is caused by the tensile strained growth on CdTe substrates. Moreover, surface quantum wells are studied. These quantum wells exhibit no or a very thin HgCdTe cap. Though, oxidization and contamination of the surface reduces here the carrier mobility immensely and a HgCdTe layer of around 5 nm provides the pleasing results for transport experiments with superconductors connected to the topological insulator [119]. A completely new achievement is the realization of MBE growth of HgTe quantum wells on CdTe/GaAs:Si substrates. This is attended by the optimization of the CdTe growth on GaAs:Si. It exposes that HgTe quantum wells grown in-situ on optimized CdTe/GaAs:Si show very nice transport data with clear Hall plateaus, SdH oscillations, low carrier densities and carrier mobilities up to 500 000 cm^2/Vs. Furthermore, a new oxide etching process is developed and analyzed which should serve as an alternative to the standard HCl process which generates volcano defects at some time. However, during the testing time the result does not differ in Nomarski, HRXRD, AFM and transport measurements. Here, long-time tests or etching and mounting in nitrogen atmosphere may provide new elaborate results. The main focus of this thesis is on the MBE growth and standard characterization of HgTe bulk layers and is discussed in chapter 6. Due to the tensile strained growth on lattice mismatched CdTe, HgTe bulk opens up a band gap of around 22 meV at the G-point and exhibits therefore its topological surface states. The analysis of surface condition, roughness, crystalline quality, carrier density and mobility via Nomarski, AFM, XPS, HRXRD and transport measurements is therefore included in this work. Layer thickness dependence of carrier density and mobility is identified for bulk layer grown directly on CdTe substrates. So, there is no clear correlation visible between HgTe layer thickness and carrier density or mobility. So, the carrier density is almost constant around 1x10^11 cm^(-2) at 0 V gate voltage. The carrier mobility of these bulk samples however scatters between 5 000 and 60 000 cm^2/Vs almost randomly. Further experiments should be made for a clearer understanding and therefore the avoidance of unusable bad samples.But, other topological insulator materials show much higher carrier densities and lower mobility values. For example, Bi2Se3 exhibits just density values around 1019 cm^(-2) and mobility values clearly below 5000 cm2/Vs. The carrier density however depends much on lithography and surface treatment after growth. Furthermore, the relaxation behavior and critical thickness of HgTe grown on CdTe is determined and is in very good agreement with theoretical prediction (d_c = 155 nm). The embedding of the HgTe bulk layer between HgCdTe layers created a further huge improvement. Similar to the quantum well structures the carrier mobility increases immensely while the carrier density levels at around 1x10^11 cm^(-2) at 0 V gate voltage as well. Additionally, the relaxation behavior and critical thickness of these barrier layers has to be determined. HgCdTe grown on commercial CdTe shows a behavior as predicted except the critical thickness which is slightly higher than expected (d_c = 850 nm). Otherwise, the relaxation of HgCdTe grown on CdTe/GaAs:Si occurs in two parts. The layer is fully strained up to 250 nm. Between 250 nm and 725 nm the HgCdTe film starts to relax randomly up to 10 %. The relaxation behavior for thicknesses larger than 725 nm occurs than linearly to the inverse layer thickness. A explanation is given due to rough interface conditions and crystalline defects of the CdTe/GaAs:Si compared to the commercial CdTe substrate. HRXRD and AFM data support this statement. Another point is that the HgCdTe barriers protect the active HgTe layer and because of the high carrier mobilities the Hall measurements provide new transport data which have to be interpreted more in detail in the future. In addition, HgTe bulk samples show very interesting transport data by gating the sample from the top and the back. It is now possible to manipulate the carrier densities of the top and bottom surface states almost separately. The back gate consisting of the n-doped GaAs substrate and the thick insulating CdTe buffer can tune the carrier density for Delta(n) ~ 3x10^11 cm^(-2). This is sufficient to tune the Fermi energy from the p-type into the n-type region [138]. In this thesis it is shown that strained HgTe bulk layers exhibit superior transport data by embedding between HgCdTe barrier layers. The n-doped GaAs can here serve as a back gate. Furthermore, MBE growth of high crystalline, undoped HgTe quantum wells shows also new and extended transport output. Finally, it is notable that due to the investigated CdTe growth on GaAs the Hg-based heterostructure MBE growth is partially independent from commercial suppliers. N2 - In der vorliegenden Dissertation wurde das MBE-Wachstum von HgTe Strukturen erforscht und die anschließende Probencharakterisierung durchgeführt und diskutiert. Durch die erste experimentelle Entdeckung des Quanten-Spin-Hall-Effekts (QSHE) in HgTe Quantentrögen hat dieses Materialsystem großes Interesse im Gebiet der Spintronics erfahren. Aufgrund der langen Wachstumshistorie von quecksilberbasierenden Heterostrukturen am Lehrstuhl Experimentelle Physik III der Universität Würzburg sind die Voraussetzungen ausgesprochen gut, um dieses Materialsystem sehr ausführlich und auch in neue Richtungen hin zu untersuchen. Da vor dieser Doktorarbeit fast ausschließlich dotierte HgTe Quantentröge auf verschiedenen Substratorientierungen gewachsen wurden, beschäftigte sich diese Dissertation nun mit dem MBE-Wachstum von undotierten HgTe Quantentrögen, oberflächennahen Quantentrögen und dreidimensionalen Volumenkristallen. Alle quecksilberbasierenden Schichten wurden hierzu auf CdTe Substraten gewachsen, welche tensile Verspannung in den Schichten erzeugten und lieferten daher neue physikalische Effekte. In der selben Zeit wurde weiterhin das Wachstum von (001) CdTe auf n-dotiertem (001) GaAs:Si erforscht, da der japanische Zulieferer der CdTe Substrate eine Lieferengpass hatte aufgrund des Tohoku Erdbebens und seinen verheerenden Folgen im Jahr 2011. Die Erforschung des MBE-Wachstums von (001) CdTe auf (001) GaAs:Si wird im Kapitel 4 behandelt. Zuerst wurde hier die Oberflächenvorbereitung des GaAs:Si Substrates durch thermische Desorption untersucht und ausgewertet. Es stellte sich heraus, dass schnelle, thermische Desorption des GaAs - Oxides mit anschließendem Abkühlen in Zn Atmosphäre die besten Ergebnisse für das spätere CdTe durch kleine Löcher an der Oberfläche liefert, während zum Beispiel ein glatter GaAs Puffer das CdTe Wachstum verschlechtert. Der folgende ZnTe Film verschafft die gewünschte (001) Wachstumsrichtung für CdTe und weist bei 30 Sekunden Wachstumszeit bei einem Flussverhältnis von Zn/Te ~ 1/1.2 die besten Endergebnisse für CdTe auf. Jedoch war die Haupterneuerung hier die Optimierung des CdTe Wachstums. Dafür wurde ein komplexer Wachstumsprozess entwickelt und etabliert. Dieser optimierte CdTe Wachstumsprozess lieferte Ergebnisse von einer RMS Rauigkeit von ungefähr 2.5 nm und FWHMWerte der HRXRD w-Scans von 150 arcsec. Die Defektätzdichte-Messung zeigte weiterhin, dass die Oberflächenkristallinität vergleichbar mit kommerziell erwerbbaren CdTe Substraten ist (um 1x10^4 cm^(-2)). Des Weiteren ist kein niedrigerer Wert für die Halbwertsbreite des w-Scans in der Literatur für diese Wachstumsrichtung aufgeführt. Dies spiricht ebenfalls für die hohe Qualität der Schichten. Jedoch ist dieser Wachstumsprozess noch nicht endgültig ausgereift und bietet weiterhin noch Platz für Verbesserungen. Das Wachstum von undotierten HgTe Quantentrögen war ebenso eine neue Forschungsrichtung im Gegensatz zu den dotierten HgTe Quantentrögen, die in der Vergangenheit gewachsen wurden. Das Ziel hierbei, die Ladungsträgerdichte zu verringern, wurde erreicht und daher ist es nun möglich, Transportexperimente sowohl im n- als auch im p-Regime durchzuführen, indem eine Gatespannung angelegt wird. Des Weiteren experimentierten andere Arbeitsgruppen mit diesen Quantentrögen, bei denen die Fermi Energie in der Bandlücke liegt [143]. Außerdem wurde das sehr präzise MBE Wachstum anhand von symmetrischen HgTe Quantentrögen und ihren HRXRD Charakterisierungen behandelt. Daher kann nun die Quantentrogdicke präzise auf 0,3 nm angegeben werden. Die Transportergebnisse von verschieden dicken Quantentrögen zeigten, dass die Ladungsträgerdichte und Beweglichkeit mit steigender HgTe Schichtdicke zunimmt. Jedoch wurde auch herausgefunden, dass sich die Bandlücke von HgTe Quantentrögen indirekt bei einer Dicke von 11.6 nm schließt. Dies wird durch das verspannte Wachstum auf CdTe Substraten verursacht. Überdies wurden oberflächennahe Quantentröge untersucht. Diese Quantentröge besitzen keine oder nur eine sehr dünne HgCdTe Deckschicht. Allerdings verringerte Oxidation und Oberflächenverschmutzung hier die Ladungsträgerbeweglichkeit dramatisch und eine HgCdTe Schicht von ungefähr 5 nm lieferte ansprechende Transportergebnisse für Supraleiter, die den topologischen Isolator kontaktieren. Eine komplett neue Errungenschaft war die Realisierung, via MBE, HgTe Quantentröge auf CdTe/GaAs:Si Substrate zu wachsen. Dies ging einher mit der Optimierung des CdTe Wachstums auf GaAs:Si. Es zeigte sich, dass HgTe Quantentröge, die in-situ auf optimierten CdTe/GaAs:Si gewachsen wurden, sehr schöne Transportergebnisse mit deutlichen Hall Quantisierungen, SdH Oszillationen, niedrigen Ladungsträgerdichten und Beweglichkeiten bis zu 500 000 cm^2/Vs erreichen. Des Weiteren wurde ein neues Oxidätzverfahren entwickelt und untersucht, welches als Alternative zum Standard-HCl-Prozess dienen sollte, da dieses manchmal vulkan-artige Defekte hervorruft. Jedoch ergab sich kein Unterschied in den Nomarski, HRXRD, AFM und Transportexperimenten. Hier könnten vielleicht Langzeittests oder Ätzen und Befestigen in Stickstoffatmosphäre neue, gewinnbringende Ergbnisse aufzeigen. Der Hauptfokus dieser Doktorarbeit lag auf dem MBE Wachstum und der Standardcharakterisierung von HgTe Volumenkristallen und wurde in Kapitel 6 diskutiert. Durch das tensil verpannte Wachstum auf CdTe entsteht für HgTe als Volumenkristall eine Bandlücke von ungefähr 22 meV am G Punkt und zeigt somit seine topologischen Oberflächenzustände. Die Analyse der Oberfächenbeschaffenheit, der Rauigkeit, der kristallinen Qualität, der Ladungsdrägerdichte und Beweglichkeit mit Hilfe von Nomarski, AFM, XPS, HRXRD und Transportmessungen ist in dieser Arbeit anzutreffen. Außerdem wurde die Schichtdickenabhängigkeit von Ladungsträgerdichte und Beweglichkeit von HgTe Volumenkristallen, die direkt auf CdTe Substraten gewachsen wurden, ermittelt worden. So erhöhte sich durchschnittlich die Dichte und Beweglichkeit mit zunehmender HgTe Schichtdicke, aber die Beweglichkeit ging selten über μ ~ 40 000 cm^2/Vs hinaus. Die Ladungsträgerdichte n hing jedoch sehr von der Litographie und der Behandlung der Oberfläche nach dem Wachstum ab. Des Weiteren wurde das Relaxationsverhalten und die kritische Dicke bestimmt, welches sehr gut mit den theoretischen Vorhersagen übereinstimmt (dc = 155 nm). Das Einbetten des HgTe Volumenkristalls in HgCdTe Schichten brachte eine weitere große Verbesserung mit sich. Ähnlich wie bei den Quantentrögen erhörte sich die Beweglichkeit μ immens, während sich die Ladungsträgerdichte bei ungefähr 1x10^11 cm^(-2) einpendelte. Zusätzlich wurde auch hier das Relaxationsverhalten und die kritische Schichtdicke dieser Barrierenschichten ermittelt. HgCdTe, gewachsen auf kommerziellen CdTe Substraten, zeigte ein Verhalten ähnlich zu dem Erwarteten mit der Ausnahme, dass die kritische Schichtdicke leicht höher ist als die Vorhergesagte (dc = 850 nm). Auf der anderen Seite findet die Relaxation von HgCdTe auf CdTe/GaAs:Si zweigeteilt ab. Bis 250 nm ist die Schicht noch voll verspannt. Zwischen 250 nm und 725 nm beginnt die HgCdTe Schicht willkürlich bis zu 10 % zu relaxieren. Das Relaxationsverhalten für Dicken über 725 nm findet dann wieder linear zur invers aufgetragenen Schichtdicke statt. Eine Erklärung wurde durch das raue Interface der Schichten und der Defekte im Kristall von CdTe/GaAs:Si gegeben, im Vergleich zu den kommerziellen CdTe Substraten. HRXRD und AFM Ergebnisse belegten diese Aussage. Die HgCdTe Barrieren schützen die aktive HgTe Schicht und daher liegen nach Hall Messungen aufgrund der hohen Ladungsträgerbeweglichkeiten neue Transportergbnisse vor, welche in der Zukunft ausführlicher interpretiert werden müssen. Darüber hinaus zeigten HgTe Volumenkristalle neue, interessante Transportergebnisse durch das gleichzeitige Benutzen eines Top- und Backgates. Es ist nun möglich, die Ladungsträger der oberen und unteren Oberflächenzustände nahezu getrennt zu verändern und zu ermitteln. Das Backgate, bestehend aus dem n-dotierten GaAs:Si Substrate und dem dicken isolierenden CdTe Puffer, kann die Ladungsträgerdichte um ungefähr Delta(n) ~ 3x10^11 cm^(-2) varieren. Das ist ausreichend, um die Fermi Energie vom p- in den n-Bereich einzustellen [138]. In dieser Dissertation wurde also gezeigt, dass verspannte HgTe Volumenkristalle durch das Einbetten in HgCdTe Barrieren neue Transportergebnisse liefern. Das n-dotierte GaAs konnte hierbei als Backgate genutzt werden. Des Weiteren zeigte das MBE Wachstum von hochkristallinen , undotiereten HgTe Quantentrögen ebenso neue und erweiterte Transportergebnisse. Zuletzt ist es bemerkenswert, dass durch das erforschte CdTe Wachstum auf GaAs das MBE Wachstum von quecksilberbasierenden Heterostrukturen auf CdTe Substraten teilweise unabhänigig ist von kommerziellen Zulieferbetrieben. KW - Quecksilbertellurid KW - Topologischer Isolator KW - MBE KW - HgTe KW - topological insulator KW - Molekularstrahlepitaxie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-151136 ER - TY - THES A1 - Breuer [geb. Hemberger], Kathrin R. F. T1 - Effiziente 3D Magnetresonanzbildgebung schnell abfallender Signale T1 - Efficient 3D Magnetic Resonance Imaging of fast decaying signals N2 - In der vorliegenden Arbeit wird die Rotated-Cone-UTE-Sequenz (RC-UTE), eine 3D k-Raum-Auslesetechnik mit homogener Verteilung der Abtastdichte, vorgestellt. Diese 3D MR-Messtechnik ermöglicht die für die Detektion von schnell abfallenden Signalen notwendigen kurzen Echozeiten und weist eine höhere SNR-Effizienz als konventionelle radiale Pulssequenzen auf. Die Abtastdichte ist dabei in radialer und azimutaler Richtung angepasst. Simulationen und Messungen in vivo zeigen, dass die radiale Anpassung das T2-Blurring reduziert und die SNR-Effizienz erhöht. Die Drehung der Trajektorie in azimutale Richtung ermöglicht die Reduzierung der Unterabtastung bei gleicher Messzeit bzw. eine Reduzierung der Messzeit ohne Auflösungsverlust. Die RC-UTE-Sequenz wurde erfolgreich für die Bildgebung des Signals des kortikalen Knochens und der Lunge in vivo angewendet. Im Vergleich mit der grundlegenden UTE-Sequenz wurden die Vorteile von RC-UTE in allen Anwendungsbeispielen aufgezeigt. Die transversalen Relaxationszeit T2* des kortikalen Knochen bei einer Feldstärke von 3.0T und der Lunge bei 1.5T und 3.0T wurde in 3D isotroper Auflösung gemessen. Außerdem wurde die Kombination von RC-UTE-Sequenz mit Methoden der Magnetisierungspräparation zur besseren Kontrasterzeugung gezeigt. Dabei wurden die Doppel-Echo-Methode, die Unterdrückung von Komponenten mit langer Relaxationszeit T2 durch Inversionspulse und der Magnetisierungstransfer-Kontrast angewendet. Die Verwendung der RC-UTE-Sequenz für die 3D funktionelle Lungenbildgebung wird ebenfalls vorgestellt. Mit dem Ziel der umfassenden Charakterisierung der Lungenfunktion in 3D wurde die simultane Messung T1-gewichteter Bilder und quantitativer T2*-Karten für verschiedene Atemzustände an sechs Probanden durchgeführt. Mit der hier vorgestellten Methode kann die Lungenfunktion in 3D über T1-Wichtung, quantitative T2*-Messung und Rekonstruktion verschiedener Atemzustände durch Darstellung von Ventilation, Sauerstofftransport und Volumenänderung beurteilt werden. N2 - In this thesis the Rotated-Cone-UTE-sequence (RC-UTE), a 3D k- space sampling scheme with uniform sampling density, is presented. 3D RC-UTE provides short echo times enabling the detection of fast decaying signals with higher SNR-efficiency than conventional UTE sequences. In RC-UTE the sampling density is adapted in radial and azimuthal direction. It is shown in simulations and measurements that the density adaption along the radial dimension reduces T2-blurring. By twisting the trajectory along the azimuthal direction fewer projections are needed to fulfill the Nyquist criterion. Thereby, undersampling artefacts or the measurement time is reduced without loss of resolution. RC-UTE has been successfully applied in vivo in cortical bone and the lung. It was shown that the RC-UTE sequence outperforms the standard UTE sequence in all presented applications. In addition, the transversal relaxation time T2* of cortical bone at field strength of 3.0T and the human lung at 1.5T und 3.0T was measured in 3D isotropic resolution. Moreover, the combination of RC-UTE with magnetization preparation techniques for improved image contrast was shown. To this end strategies such as double-echo readout, long T2 suppression by inversion pulses and magnetization transfer contrast imaging were employed. Furthermore, the application of RC-UTE for 3D functional lung imaging is presented. In order to provide broad information about pulmonary function T1-weighted images and quantitative T2*-maps in different breathing states were simultaneously measured in six healthy volunteers. The presented methodology enables the assessment of pulmonary function in 3D by indicating ventilation, oxygen transfer and lung volume changes during free breathing. KW - Kernspintomografie KW - Relaxationszeit KW - Dreidimensionale Bildverarbeitung KW - T2* KW - Ulrakurze Echozeit KW - T1-Wichtung KW - dichteangepasste k-Raum Abtastung KW - Lunge KW - Relaxation KW - Lungenfunktion Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150750 ER - TY - THES A1 - Rotem, Elam T1 - Early Basso Continuo Practice: Implicit Evidence in the Music of Emilio de' Cavalieri T1 - Frühe Basso Continuo-Praxis: Implizite Evidenz in der Musik Emilio de' Cavalieris N2 - In this work, Emilio de’ Cavalieri’s musical sources will serve as a platform in an attempt to overcome the lack of explicit original guidance and guidelines of performance practice of early basso continuo. It will offer a methodology that will allow the unraveling of implicit theory and practice hidden in the music sources themselves. The methodology of this work is based on the fact that Cavalieri’s Rappresentatione di Anima e di Corpo (Rome, 1600) is printed using a unique continuo notation, which is detailed, precise, and coherent—more so than any other contemporaneous printed source. Through thorough investigation of this continuo notation, it will be possible to enrich our practical as well as theoretical knowledge of the early basso continuo. A wide range of evidences will emerge, covering a wide spectrum, from general questions of instrumentation up to the very notes that should be played. Using a special notation for illustration, I will demonstrate how Cavalieri’s basso continuo figuration, when combined with the known rules of counterpoint, is at times equivalent to written-out realizations. As part of this study, different models of contrapuntal phenomena will be analyzed, mainly in the context of cadences but also in the context of other progressions that deserve to be recognized as formulas. Their theoretical structure will be uncovered as well as their actual application in music and their manner of execution. The prevalence of each phenomenon will be examined in order to distinguish common and recurrent phenomena from rarely-used formulas. In order to do this, and due to problematic historical terminology, it will be necessary to create a set of new terms inspired by Cavalieri’s notation. Those terms will not be solely relevant to Cavalieri’s music; the models were made flexible so that they may prove useful for future discussions or studies of early continuo in general. Out of the known early basso continuo sources, a “mini-compendium” of practical implications will be extracted in order to exhaust the practical knowledge implicit in them. This endeavor will be concluded with a list of rules and general advice drawn from the sources, but it will also reveal some problematic aspects of these sources. This endeavor will make it possible to compare the “new” implicit practical information deduced in this study with the explicit known continuo sources, and assess to what extant Cavalieri’s continuo practices illuminate and complement the known knowledge from previously-studied yet opaque sources of basso continuo. The focus of this dissertation is on Cavalieri’s music, but the findings proposed here will be traced so as to illuminate the broader realm of the early Baroque and the 17th century musical style at large. Finally, this new research about Cavalieri’s music and continuo, along reevaluating of its place among the common continuo sources, calls for redistribution of source materials on the traditional “shelf” of early basso continuo sources. N2 - Frühe Basso Continuo-Praxis: Implizite Evidenz in der Musik Emilio de' Cavalieris KW - Performance practice KW - Early Music KW - Early Basso Continuo Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-145079 N1 - eine 2., ergänzte Fassung der Arbeit finden Sie unter: http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-145696 ER - TY - THES A1 - Beitzen-Heineke, Antonia T1 - Invariant Natural Killer T cells possess immune-modulating functions during \(Aspergillus\) \(fumigatus\) infection T1 - Invariante Natürliche Killer T Zellen besitzen immunmodulierende Funktionen in der \(Aspergillus\) \(fumigatus\) Abwehr N2 - Aspergillus fumigatus is the most common cause for invasive fungal infections, a disease associated with high mortality in immune-compromised patients. CD1d-restricted invariant Natural Killer T (iNKT) cells compose a small subset of T cells known to impact the immune response towards various infectious pathogens. To investigate the role of human iNKT cells during A. fumigatus infection, we studied their activation as determined by CD69 expression and cytokine production in response to distinct fungal morphotypes in the presence of different CD1d⁺ antigen presenting cells using flow cytometry and multiplex ELISA. Among CD1d⁺ subpopulations, CD1d⁺CD1c⁺ mDCs showed the highest potential to activate iNKT cells on a per cell basis. The presence of A. fumigatus decreased this effect of CD1d⁺CD1c⁺ mDCs on iNKT cells and led to reduced secretion of TNF-α, G-CSF and RANTES. Production of other Th1 and Th2 cytokines was not affected by the fungus, suggesting an immune-modulating function for human iNKT cells during A. fumigatus infection. N2 - Aspergillus fumigatus ist der häufigste Erreger von invasiven Pilzinfektionen, welche bei immunsupprimierten Patienten mit einer hohen Mortalität einhergehen. CD1d-abhängige invariante Natürliche Killer T (iNKT) Zellen sind eine kleine Subpopulation von T-Zellen, die die Immunantwort auf verschiedene Erreger beeinflussen. Um die Rolle von humanen iNKT Zellen in der Aspergillus fumigatus Abwehr zu untersuchen, wurde in Ko-Kulturen mit iNKT Zellen und CD1d⁺ Antigen präsentierenden Zellen in Anwesenheit von verschiedenen fungalen Morphotypen der Aktivierungsmarker CD69 und die Zytokinproduktion mittels Durchflusszytometrie und Multiplex ELISA untersucht. Unter den CD1d⁺ Subpopulationen wiesen die CD1d⁺CD1c⁺mDCs das höchste aktivierende Potential auf iNKT Zellen auf. Die Anwesenheit von A. fumigatus reduzierte diesen Effekt von CD1d⁺CD1c⁺mDCs auf iNKT Zellen und führte zu einer reduzierten Sekretion von TNF-α, G-CSF und RANTES. Die Produktion von anderen Th1 und Th2 Zytokinen war nicht durch den Pilz beeinflusst. Diese Arbeit suggeriert eine immunmodulierende Funktion von humanen iNKT Zellen in der Abwehr von A. fumigatus. KW - Aspergillus fumigatus KW - T Zelle KW - iNKT KW - CD1d KW - CD1c⁺ mDC Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-144966 ER - TY - THES A1 - Kutzer, Pia Elfriede Seyra T1 - Langzeitergebnisse einer steroidfreien Immunsuppression ein Jahr nach Nierentransplantation T1 - Long-term results of a steroid-free immunosuppressive regimen one year after renal transplantation N2 - Die Transplantation nimmt, mehr noch als die verschiedenen Dialyseverfahren, den höchsten Stellenwert in der Therapie eines terminalen Nierenversagens ein. Eine Transplantation erfordert jedoch auch immer eine suffiziente Immunsuppression, ohne die die Funktionalität des Transplantats nicht gewährleistet werden kann. Kortikosteroide werden dabei immer noch sehr häufig nach Nierentransplantation eingesetzt. Jedoch bringt diese Medikation auch Risiken mit sich. In der vorliegenden retrospektiven Analyse wurden die Daten von insgesamt 809 Patienten ausgewertet. Die Patienten wurden in zwei Gruppen aufgeteilt, wobei zwischen steroidfrei und nicht-steroidfrei in Jahr zwei nach Transplantation unterschieden wurde. Untersucht wurde, ob es Unterschiede im Patienten- und Transplantatüberleben, bei akuten Abstoßungen oder bei steroidtypischen Nebenwirkungen gibt. Wir konnten ein tendenziell besseres Patientenüberleben in der steroidfreien Gruppe feststellen, vor allem zu sehen an der Zehn-Jahres-Überlebensrate (86,0% vs. 79,8%). Bezüglich des Transplantatüberlebens zeigte sich ein statistisch signifikanter Unterschied zugunsten der steroidfreien Patienten (nach fünf Jahren 92,2% vs. 79,7%). Ein Transplantatverlust war in der steroidfreien Kohorte seltener zu beobachten (23,1% vs. 33,8%). Bei den in Jahr zwei steroidfreien Patienten ereigneten sich weniger akute Abstoßungsereignisse, sowohl bioptisch gesicherte als auch nur klinisch verdächtige Episoden. Steroidtypische Nebenwirkungen, zum Beispiel ein Posttransplantationsdiabetes sowie kardiovaskuläre Ereignisse wurden tendenziell häufiger in der Kohorte mit fortgesetzter Steroideinnahme diagnostiziert. Im Auftreten von Malignomen gab es keinen Unterschied zwischen den beiden Gruppen. Zu beachten ist die Möglichkeit eines Selektionsbias bei der retrospektiven Auswertung. Somit ergeben sich in unserer Analyse für eine verkürzte Einnahme von Steroiden nach Transplantation greifbare Vorteile für das Patienten- und Transplantatüberleben. Die Steroidtherapie sollte jedoch mindestens bis sechs Monate nach Transplantation beibehalten werden. Nach diesem Zeitraum erscheint das Absetzen der Steroide sicherer zu sein, da akute Abstoßungsepisoden seltener auftreten. Sowohl Patienten- und Transplantatüberleben werden durch das Absetzen der Steroidtherapie günstig beeinflusst. Ein früheres Absetzen, wie es in anderen Studien durchgeführt wurde, führte häufiger zu höheren Raten an akuten Rejektionen. Kortikosteroide waren und bleiben somit ein unverzichtbarer Teil der initialen immunsuppressiven Therapie nach Nierentransplantation. N2 - We analyzed the long-term results of a steroid-free immunosuppressive regimen one year after renal transplantation. In this retrospective analysis 809 patients were included who underwent renal transplantation between 1984 an 2012. The patients were divided into two groups: Patients who continued taking steroids one year after transplantation and patients who were withdrawn from steroids after one year after transplantation. Both groups were matched for baseline parameters. In the steroid withdrawal-group we found lower overall-mortality rates compared to steroid-continuation-patients. Also there were less graft losses in the CSW group. KW - Nierentransplantation KW - Immunsuppression KW - corticosteroid withdrawal KW - corticosteroid-free immunosuppression after renal transplantation Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-141586 ER - TY - THES A1 - Schwarz, Christoph Benjamin T1 - Full vector-field control of femtosecond laser pulses with an improved optical design T1 - Vollständige Kontrolle des Vektorfelds von Femtosekunden-Laserpulsen mit einem verbesserten optischen Design N2 - The controlled shaping of ultrashort laser pulses is a powerful technology and applied in many laser laboratories today. Most of the used pulse shapers are only able to produce linearly polarized pulses shaped in amplitude and phase. Some devices are also capable of producing limited time-varying polarization profiles, but they are not able to control the amplitude. However, for some state-of-the-art non-linear time-resolved methods, such as polarization-enhanced two-dimensional spectroscopy, the possibility of controlling the amplitude and the polarization simultaneously is desirable. Over the last years, different concepts have been developed to overcome these restrictions and to manipulate the complete vector-field of an ultrashort laser pulse with independent control over all four degrees of freedom - phase, amplitude, orientation, and ellipticity. The aim of this work was to build such a vector-field shaper. While the basic concept used for our setup is based on previous designs reported in the literature, the goal was to develop an optimized optical design that minimizes artifacts, allowing for the generation of predefined polarization pulse sequences with the highest achievable accuracy. In Chapter 3, different approaches reported in the literature for extended and unrestricted vector-field control were examined and compared in detail. Based on this analysis, we decided to follow the approach of modulating the spectral phase and amplitude of two perpendicularly polarized pulses independently from each other in two arms of an interferometer and recombining them to a single laser pulse to gain control over the complete vector field. As described in Chapter 4, the setup consists of three functional groups: i) an optical component to generate and recombine the two polarized beams, ii) a 4f setup, and iii) a refracting telescope to direct the two beams under two different angles of incidence onto the grating of the 4f setup in a common-path geometry. This geometry was chosen to overcome potential phase instabilities of an interferometric vector-field shaper. Manipulating the two perpendicularly polarized pulses simultaneously within one 4f setup and using adjacent pixel groups of the same liquid-crystal spatial light modulator (LC SLM) for the two polarizations has the advantages that only a single dual-layer LC SLM is required and that a robust and compact setup was achieved. The shaping capabilities of the presented design were optimized by finding the best parameters for the setup through numerical calculations to adjust the frequency distributions for a broad spectrum of 740 – 880 nm. Instead of using a Wollaston prism as in previous designs, a thin-film polarizer (TFP) is utilized to generate and recombine the two orthogonally polarized beams. Artifacts such as angular dispersion and phase distortions along the beam profile which arise when a Wollaston prism is used were discussed. Furthermore, it was shown by ray-tracing simulations that in combination with a telescope and the 4f setup, a significant deformation of the beam profile would be present when using a Wollaston prism since a separation of the incoming and outgoing beam in height is needed. The ray-tracing simulations also showed that most optical aberrations of the setup are canceled out when the incoming and outgoing beams propagate in the exact same plane by inverting the beam paths. This was realized by employing a TFP in the so-called crossed-polarizer arrangement which has also the advantage that the polarization-dependent efficiencies of the TFP and the other optics are automatically compensated and that a high extinction ratio in the order of 15000:1 is reached. Chromatic aberrations are, however, not compensated by the crossed-polarizer arrangement. The ray-tracing simulations confirmed that these chromatic aberrations are mainly caused by the telescope and not by the cylindrical lens of the 4f setup. Nevertheless, in the experimentally used wavelength range of 780 – 816 nm, only minor distortions of the beam profile were observed, which were thus considered to be negligible in the presented setup. The software implementation of the pulse shaper was reviewed in Chapter 5 of this thesis. In order to perform various experiments, five different parameterizations, accounting for the extended shaping capabilities of a vector-field shaper, were developed. The Pixel Basis, the Spectral Basis, and the Spectral Taylor Basis can generally be used in combination with an optimization algorithm and are therefore well suited for quantum control experiments. For multidimensional spectroscopy, the Polarized Four-Pulse Basis was established. With this parameterization pulse sequences with up to four subpulses can be created. The polarization state of each subpulse can be specified and the relative intensity, phase, and temporal delay between consecutive subpulses can be controlled. In addition, different software programs were introduced in Chapter 5 which are required to perform the experiments conducted in this work. The experimental results were presented in Chapter 6. The frequency distribution across the LC SLM was measured proving that the optimal frequency distribution was realized experimentally. Furthermore, the excellent performance of the TFP was verified. In general, satellite pulses are emitted from the TFP due to multiple internal reflections. Various measurements demonstrated that these pulses are temporally separated by at least 4.05 ps from the main pulse and that they have vanishing intensity. The phase stability between the two arms of the presented common-path setup σ = 28.3 mrad (λ/222) over 60 minutes. To further improve this stability over very long measurement times, an on-the-fly phase reduction and stabilization (OPRAS) routine utilizing the pulse shaper itself was developed. This routine automatically produces a compressed pulse with a minimized relative phase between the two polarization components. A phase stability of σ = 31.9 mrad (λ/197) over nearly 24 hours was measured by employing OPRAS. Various pulse sequences exceeding the capabilities of conventional pulse shapers were generated and characterized. The experimental results proved that shaped pulses with arbitrary phase, amplitude, and polarization states can be created. In all cases very high agreement between the target parameters and the experimental data was achieved. For the future use of the setup also possible modifications were suggested. These are not strictly required, but all of them could further improve the performance and flexibility of the setup. Firstly, it was illustrated how a “dual-output” of the setup can be realized. With this modification it would be possible to use the main intensity of the shaped pulse for an experiment while using a small fraction to characterize the pulse or to perform OPRAS simultaneously. Secondly, the basic idea of replacing the telescope by focusing mirrors in order to eliminate the chromatic aberrations was presented. Regarding the different parameterizations for vector-field shaping, some modifications increasing the flexibility of the implemented bases and the realization of a von Neumann Basis for the presented setup were proposed. In future experiments, the vector-field shaper will be used in conjunction with a photoemission electron microscope (PEEM). This approach combines the temporal resolution provided by ultrashort laser pulses with the high spatial resolution gained by electron microscopy in order to perform two-dimensional spectroscopy and coherent control on nanostructures with polarization-shaped femtosecond laser pulses. In combination with other chiral-sensitive experimental setups implemented earlier in our group, the vector-field shaper opens up new perspectives for chiral femtochemistry and chiral control. The designed vector-field shaper meets all requirements to generate high-precision polarization-shaped multipulse sequences. These can be used to perform numerous polarization-sensitive experiments. Employing the OPRAS routine, a quasi-infinitely long phase stability is achieved and complex and elaborated long-term measurements can be carried out. The fact that OPRAS demands no additional hardware and that only a single dual-layer LC SLM and inexpensive optics are required allows the building of a vector-field shaper at comparatively low costs. We hope that with the detailed insights into the optical design process as well as into the software implementation given in this thesis, vector-field shaping will become a standard technique just as conventional pulse shaping in the upcoming years. N2 - Die gezielte Formung ultrakurzer Laserpulse ist eine leistungsstarke Technik, die heutzutage in vielen Laserlaboren eingesetzt wird. Die meisten Pulsformer können jedoch nur linear polarisierte, in Phase und Amplitude geformte Laserpulse erzeugen. Einige Pulsformer können auch sich zeitlich verändernde Polarisationszustände generieren. Die möglichen Polarisationszustände sind allerdings beschränkt und eine gleichzeitige Formung der Amplitude ist dann nicht mehr möglich. Für einige moderne, nicht-lineare, zeitaufgelöste, spektroskopische Methoden, wie z.B. die polarisationsunterstützte zweidimensionale Spektroskopie, ist aber die gleichzeitige Kontrolle über die Polarisation und die Amplitude erstrebenswert. In den letzten Jahren wurden verschiedene Konzepte entwickelt, um diese Beschränkungen zu überwinden und eine vollständige Kontrolle des Vektorfeldes über die vier Freiheitsgrade Phase, Amplitude, Orientierung und Elliptizität eines ultrakurzen Laserpulses zu erlangen. Ziel dieser Arbeit war es, einen solchen Vektorfeldformer zu konstruieren. Die Grundidee für das Design unseres Aufbaus basiert auf verschiedenen literaturbekannten Konzepten. Unser Ziel war es jedoch, ein optimiertes Design zu entwickeln, bei dem Formungsartefakte minimal sind und definierte polarisationsgeformte Mehrfachpulse mit der höchstmöglichen Genauigkeit erzeugt werden können. In Kapitel 3 wurden verschiedene vorherige Ansätze für die erweiterte und vollständige Vektorfeldkontrolle detailliert geprüft und verglichen. Basierend auf dieser Analyse haben wir uns dazu entschlossen, das Konzept eines interferometrischen Vektorfeldformers zu verwenden. Bei diesem werden die spektrale Phase und Amplitude zweier orthogonal polarisierter Pulse unabhängig voneinander in den zwei Armen eines Interferometers manipuliert und durch Überlagerung dieser zwei Pulse die vollständige Kontrolle über das Vektorfeld erlangt. Wie in Kapitel 4 beschrieben, besteht der Aufbau aus drei funktionellen Gruppen: i) einer optischen Komponente, um die zwei polarisierten Strahlen zu erzeugen und zu rekombinieren, ii) einem sog. 4f-Aufbau und iii) einem Linsenteleskop, um die zwei Strahlen unter unterschiedlichen Winkeln auf das Gitter des 4f-Aufbaus zu lenken, so dass beide Strahlen über dieselben Optiken propagieren. Diese Art der Strahlführung wurde gewählt, um die interferometrische Stabilität des Aufbaus zu verbessern. Beide Strahlen werden mit demselben 4f-Aufbau geformt, indem unterschiedliche benachbarte Pixelbereiche des Flüssigkristall-Lichtmodulators (LC SLM, engl. liquid-crystal spatial light modulator) für die zwei Polarisationskomponenten genutzt werden. Das hat den Vorteil, dass nur ein einzelnes zweilagiges LC SLM benötigt wird und so ein kompakter und robuster Aufbau realisiert werden konnte. Um die Frequenzverteilung für einen breiten Spektralbereich von 740 – 880 nm anzupassen, wurden die besten Parameter für den Aufbau anhand numerischer Berechnungen bestimmt, und somit die Formungsmöglichkeiten unseres Vektorfeldformers optimiert. Im Gegensatz zu anderen Designs wird ein Dünnschicht-Polarisator (TFP, engl. thin-film polarizer) anstelle eine Wollaston-Prismas verwendet, um die zwei senkrecht zueinander polarisierten Strahlen zu erzeugen und zu rekombinieren, da ein Wollaston-Prisma Artefakte wie Winkelchirp und eine über das Strahlprofiel variierende Phase verursacht. Bei Verwendung eines Wollaston-Prismas muss zudem der rekombinierte Strahl gegenüber des einfallenden Strahls in der Höhe verkippt werden, um beide räumlich trennen zu können. Raytracing-Simulationen haben gezeigt, dass dies in Kombination mit einem Teleskop und dem 4f-Aufbau zu einer erheblichen Deformierung des Strahlprofiles führt. Diese Simulationen haben auch gezeigt, dass die Abbildungsfehler des Aufbaus weitestgehend aufgehoben werden, wenn der eingehende und ausgehende Strahl in derselben Ebene propagieren und somit die Strahlwege genau invertiert werden. Dies konnte mit Hilfe des TFPs in einer Konfiguration, die gekreuzten Polarisatoren entspricht, realisiert werden. Diese Konfiguration hat zudem den Vorteil, dass dadurch die polarisationsabhängige Effizienz des TFPs und der anderen Optiken automatisch kompensiert wird und ein hohes Auslöschungsverhältnis in der Größenordnung 15000:1 erzielt wird. Die chromatische Aberration wird allerdings durch diese Polarisator-Konfiguration nicht aufgehoben. Durch Raytracing wurde bestätigt, dass diese primär durch das Teleskop verursacht wird und nicht durch die Zylinderlinse des 4f-Aufbaus. Allerdings wurden im experimentell genutzten Wellenlängenbereich von 780 – 816 nm nur geringe Störungen des Strahlprofiles beobachtet, die daher als vernachlässigbar angesehen wurden. Die softwareseitige Umsetzung der Vektorfeldkontrolle wurde in Kapitel 5 beschrieben. Um verschiedene Experimente durchführen zu können, wurden fünf Parametrisierungen entwickelt, bei denen die erweiterten Formungsmöglichkeiten eines Vektorfeldformers berücksichtigt wurden. Die Pixel Basis, die Spectral Basis und die Spectral Taylor Basis können zusammen mit einem Optimierungsalgorithmus verwendet werden und sind damit bestens für Experimente der Quantenkontrolle geeignet. Für die multidimensionale Spektroskopie wurde die Polarized Four-Pulse Basis eingeführt. Mit dieser Parametrisierung können Mehrfach-Pulssequenzen mit bis zu vier Pulsen erzeugt werden. Dabei kann der Polarisationszustand jedes Pulses vorgegeben und die relative Intensität, Phase und der zeitliche Abstand aufeinanderfolgender Pulse festgelegt werden. Zusätzlich wurden in Kapitel 5 verschieden Softwareprogramme vorgestellt, die für die in dieser Arbeit durchgeführten Experimente notwendig sind. Die experimentellen Ergebnisse wurden in Kapitel 6 präsentiert. Die Frequenzverteilung am LC SLM wurde gemessen und dabei bewiesen, dass die optimale Frequenzverteilung experimentell realisiert werden konnte. Des Weiteren wurden die exzellenten Eigenschaften des TFPs bestätigt. Im Allgemeinen emittiert der TFP Satellitenpulse durch interne Mehrfachreflexe. Mehrere Messungen haben jedoch gezeigt, dass diese Satellitenpulse einen zeitlichen Abstand von mindesten 4,05 ps vom Hauptpuls aufweisen und dass deren Intensität verschwindend gering ist. Die Phasenstabilität des Aufbaus beträgt σ = 28,3 mrad (λ/222) über einen Zeitraum von einer Stunde. Um die Stabilität für sehr lange Messzeiten zu verbessern, wurde eine Routine zur Phasenreduktion und zur Stabilisierung (OPRAS, engl. on-the-fly phase reduction and stabilization) unter Einbeziehung des Pulsformers entwickelt. Diese Routine erzeugt automatisiert einen komprimierten Puls mit minimierter relativer Phase zwischen den zwei Polarisationskomponenten und ermöglicht so eine Phasenstabilität von σ = 31,9 mrad (λ/197) über nahezu 24 Stunden. Ferner wurden verschieden Pulssequenzen erzeugt und charakterisiert, die die Möglichkeiten der konventionellen Pulsformung übertreffen. Die experimentellen Ergebnisse zeigen, dass geformte Pulse mit beliebigen Phasen, Amplituden und Polarisationszuständen generiert werden können. In allen Fällen wurde eine sehr hohe Übereinstimmung zwischen den Zielparametern und den experimentellen Daten erreicht. Für den zukünftigen Einsatz des Aufbaus wurden mögliche Erweiterungen vorgeschlagen. Diese sind nicht zwingend erforderlich, könnten aber die Leistung und die Einsatzmöglichkeiten des Vektorfeldformers weiter verbessern. Erstens wurde aufgezeigt, wie zwei Ausgangsstrahlen erzeugt werden könnten. Mit dieser Veränderung wäre es möglich, den größten Teil der Intensität des geformten Strahls für ein Experiment zu nutzen und gleichzeitig einen geringen Anteil für die Pulscharakterisierung oder für die Phasenstabilisierung mit der entwickelten Routine zu verwenden. Um chromatische Aberration zu vermeiden, wurde zweitens die prinzipielle Idee, das Linsenteleskop durch fokussierende Spiegel zu ersetzen, diskutiert. Für die verschiedenen erarbeiteten Parametrisierungen zur Vektorfeldkontrolle wurden einige Erweiterungen vorgeschlagen, um deren Einsatzmöglichkeiten noch weiter zu erhöhen. Außerdem wurde noch die Möglichkeit einer von Neumann Basis für den präsentierten Aufbau aufgezeigt. In zukünftigen Experimenten wird unser Aufbau mit einem Photoemissionselektronenmikroskop (PEEM) kombiniert. Dadurch kann die zeitliche Auflösung ultrakurzer Laserpulse mit der hohen räumlichen Auflösung der Elektronenmikroskopie vereint werden, was die zweidimensionale Spektroskopie und Quantenkontrolle von Nanostrukturen mit Hilfe polarisationsgeformter Femtosekunden-Laserpulse ermöglicht. Der Vektorfeldformer eröffnet in Verbindung mit anderen zuvor in unserer Gruppe implementierten chiral sensitiven Versuchsaufbauten neue Perspektiven für die chirale Femtochemie und Kontrolle. Der erarbeitete Vektorfeldformer erfüllt alle Anforderungen, um polarisationsgeformte Mehrfachpulssequenzen mit hoher Präzision zu erzeugen. Diese können verwendet werden, um zahlreiche polarisationssensitive Experimente durchzuführen. Durch die Stabilisierungsroutine OPRAS wird eine quasi unendlich lange Phasenstabilität des Aufbaus gewährleistet und komplexe und aufwendige Langzeitmessungen können ausgeführt werden. Die Tatsache, dass OPRAS keine weitere Hardware benötigt und der Aufbau nur einen einzigen zweilagigen Flüssigkristall-Lichtmodulator sowie ansonsten verhältnismäßig günstige Optiken erfordert, ermöglicht den Bau eines Vektorfeldformers zu vergleichsweise niedrigen Kosten. Wir hoffen, dass andere Forschergruppen von den detailreichen Einblicken in den Designprozess und die Software-Implementierung profitieren und dass die vollständige Vektorfeldformung in den nächsten Jahren genauso wie die konventionelle Pulsformung zu einer Standard-Technologie wird. KW - Ultrakurzer Lichtimpuls KW - vector-field shaper KW - vector-field control KW - polarization pulse shaping KW - femtosecond pulse shaping KW - Vektorfeldformer KW - Vektorfeldkontrolle KW - Polarisationspulsformung KW - Femtosekunden Pulsformung KW - Femtosekundenbereich KW - Impulsformung KW - Femtosekundenlaser Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142948 ER - TY - THES A1 - Dischinger, Ulrich Severin T1 - Auswirkungen unterschiedlicher Haltungsbedingungen auf Phänotyp und Genexpression im Mausmodell T1 - Effects of different environmental conditions on phenotype and gene expression in the mouse model N2 - In zahlreichen Untersuchungen konnte gezeigt werden, dass Umweltbedingungen im frühen Lebensalter einerseits die Entwicklung von Resilienz, d.h. Widerstandsfähigkeit gegenüber Stressoren, andererseits aber auch die Entwicklung physischer und psychischer Erkrankungen im weiteren Lebensverlauf beeinflussen können. Dabei wird angenommen, dass sich sowohl dezidiert positive als auch in Maßen aversive Umweltbedingungen mit rezidivierender Stressbelastung günstig auf die Resilienz im späteren Leben auswirken können. Auf neurobiologischer Ebene scheinen dabei das CRH und seine Rezeptoren (CRHR1 und CRHR2), das NPY-System sowie das NPS-System (insbesondere NPS-Rezeptor) eine besondere Rolle zu spielen. Jedoch sind die exakten Zusammenhänge und neurobiologischen Grundlagen weiterhin nur unzureichend aufgeklärt. Dies ist insbesondere insofern bedauernswert, da weiterer Erkenntnisgewinn auf diesem Gebiet möglicherweise Präventionsstrategien und Therapieoptionen für den Menschen begründen könnte. Um die Auswirkung der Umweltbedingungen im frühkindlichen Lebensalter auf die Resilienz im späteren Leben weiter aufzuklären, wurden im Rahmen dieser Arbeit insgesamt 310 Cd1-Mäuse den Haltungsbedingungen "Environmental Enrichment" (EE, Stimulation durch Spielobjekte) und "Maternal separation" (MS, wiederholte Stressbelastung durch Separation der Nachkommen vom Muttertier) sowie Standardhaltungsbedingungen unterworfen. Insgesamt 31 männlichen Tieren wurde im Alter von vier Wochen die Gehirne entnommen und aus diesen jeweils die Regionen Frontalcortex, Striatum, Nucleus accumbens, Hippocampus, Amygdala, dorsale Nuclei raphes und Hypothalamus herauspräpariert. Aus den gewonnenen Proben wurde RNA extrahiert, hieraus cDNA synthetisiert und abschließend - nach Ausschluss von Kontamination und Integritätsprüfung - die Expressionsraten der untersuchten Gene mittels RT-qPCR quantifiziert. Um auch verhaltensbiologische Konsequenzen der unterschiedlichen Haltungsbedingungen zu erfassen, wurden außerdem 30 weibliche sowie 30 männliche Tiere im weiteren Lebensverlauf verschiedenen Verhaltenstests zugeführt. In den Sucrose-Präferenz-Tests zeigten sich Effekte der Haltungsbedingung auf Sucrose-Konsum und Präferenz mit signifikant geringeren Werten der Haltungsgruppe EE. Bei der Auswertung der Openfield-Tests fanden sich Gruppen-Geschlechter-Interaktionseffekte mit signifikant geringeren Werten (Gesamtstrecke, Strecke und Aufenthaltsdauer im zentralen Bereich, Eintritte in den zentralen Bereich) der weiblichen EE-Tiere. In den Barnes Maze-Tests benötigten die Tiere der Haltungsgruppe EE an den meisten Testtagen signifikant weniger Zeit, um in die Escape-Box zu "entkommen". Auf neurobiologischer Ebene fanden sich signifikante Unterschiede der CRH-Expressionsraten in Amygdalae und Frontalcortex, der CRHR 1-Expressionsraten in Amygdalae und Hypothalamus sowie der CRHR2-Expressionsraten in Amygdalae und Hippocampus. Demgegenüber konnte kein signifikanter Effekt der Haltungsbedingung auf das NPY-System gefunden werden. Jedoch ließen sich signifikante Unterschiede der NPSR1-Expressionsraten in Amygdalae, Frontalcortex, dorsalen Nuclei raphes und Hypothalamus feststellen. Es kann also grundsätzlich von Auswirkungen unterschiedlich aversiver Haltungsbedingungen auf die Stress-Resilienz von Versuchstieren ausgegangen werden. Dies ist einerseits für Tierversuche allgemein von grundsätzlicher Bedeutung. Andererseits legen die Resultate eine entsprechende frühkindliche "Programmierung" auch im Menschen nahe. N2 - Chronic stress leads to several somatic and psychiatric diseases. Especially chronic stress in early stages of life predisposes to psychiatric disease in later life due to plasticity and therefore adaptability of the human brain in early life. On the other side repeated stress as well as decidedly positive conditions in early life potentially lead to resilience against stressors in later life. Data from animal studies suggest both options. Further insight into this matter could establish new prevention strategies in humans. The aim of this paper was to further examine the consequences of repeated stress on behaviour and gene expression in later life compared to decidedly positive conditions in a mouse model. Several genes, which play a role in stress processing, were examined, the CRH system, the NPY system and the NPS receptor. We found several effects of repeated stress vs. decidedly positive conditions in early life on behaviour and gene expression in later life, which were unfortunately not consistent. Further studies should be undertaken to gain further insight into this matter. KW - Stress KW - Resilienz KW - Prävention KW - Stress KW - Resilienz KW - resilience KW - Prävention KW - Prevention Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142955 ER - TY - THES A1 - Sieker, Jakob Tobias T1 - Direkter adenoviraler Gentransfer von Bone morphogenetic protein-2 und Indian Hedgehog zur Knorpelregeneration im Kaninchenmodell T1 - Direct adenoviral bone morphogenetic protein 2 and Indian hedgehog gene transfer for articular cartilage repair in a rabbit model N2 - Einleitung Fokale Gelenkknorpeldefekte treten in der Deutschen Bevölkerung mit einer geschätzten Inzidenz von über 300 000 jährlichen Fällen auf. In der US-amerikanischen Bevölkerung wird jährlich von über 600 000 Fällen ausgegangen. Aufgrund der Insuffizienz körpereigener Heilungskapazitäten und verfügbarer Therapieverfahren, schreitet die Erkrankung regelhaft zur post-traumatischen Arthrose fort. Neben der individuellen Lebensqualitätseinschränkung besteht eine sozioökonomische Bedeutung mit geschätzten Krankheitskosten von jährlich über 10 Milliarden US Dollar in den Vereinigten Staaten. Das Versagen zellbasierter Therapieverfahren beruht unter anderem auf einer Insuffizienz der chondrogenen Differenzierung, sowie der hypertrophen Differenzierung der Chondrozyten mit nachfolgender Osteogenese analog den Vorgängen in der Wachstumsfuge. Für die Induktion der chondrogenen Differenzierung stehen insbesondere Mitglieder der TGF-β Superfamilie, wie BMP-2, zur Verfügung. Diese sind jedoch ebenso durch eine Induktion der hypertrophen Differenzierung gekennzeichnet. Zur Induktion der Chondrogenese unter Umgehung der TGF-β-Signalwege wurde IHH in-vitro als vielversprechend beschrieben. Bislang besteht jedoch kein Nachweis der in-vivo Effektivität von IHH zur Knorpelreparation. Die Schaffung eines Wachstumsfaktor-Milieus in der Gelenkknorpelläsion in-vivo stellt ebenso eine Herausforderung dar. Diesbezüglich wurde ein vereinfachtes Verfahren zum lokalisierten in-vivo Gentransfer mittels adenoviraler Vektoren und autologen Knochenmarkskoagulaten anhand von Markergenen beschrieben. Die Effektivität jenes Verfahrens zur in-vivo Knorpelreparation wurde noch nicht gezeigt. Zweck dieses kontrollierten in-vivo Experimentes ist es, mittels des oben genannten Gentransferverfahrens die Wirksamkeit von BMP-2 und IHH zur Reparation von osteochondralen Defekten in New Zealand White Rabbits nachzuweisen. Die zentrale Hypothese lautete, dass BMP2 beziehungsweise IHH Gentransfer in einer höheren langzeit-histologischen Qualität des Reparationsgewebes resultiert. Explorativ sollten dabei Unterschiede in den einzelnen Dimensionen der Gewebequalität anhand des ICRS-II Histology Scoring Systems, sowie der Grad der Typ I (als Faserknorpelmarker), Typ II (als Marker hyalinen Gelenkknorpels) und Typ X Kollagen Deposition (als Marker hypertropher Chondrozyten) beschrieben werden. Material und Methoden Als Tiermodel wurden bilaterale 3,2 mm durchmessende osteochondrale Bohrlochdefekte in der Trochlea von New Zealand White Rabbits verwendet (n=10 unabhängige Tiere, 20 Gelenke). Die Defekte wurden mit autologen Knochenmarkkoageln gefüllt, die nach vorheriger Beckenkammaspiration gewonnen wurden. In den experimentellen Gruppen wurden die Knochenmarkkoagel beladen mit jeweils 1 x 1011 infektiösen Partikeln adenoviraler Vektoren, die cDNA codierend für BMP2 (n=3 Tiere, entsprechend 6 Gelenken) oder IHH (n=4; 8) enthielten. In der Kontrollgruppe wurde das nicht-chondrogene Markergen GFP (n=3; 6) transferiert. Beide Gelenke eines Tieres wurden der gleichen Gruppe zugeordnet. Die histologische Gewebequalität wurde nach 13 Wochen anhand des ICRS-II Scoringsystems durch 3 unabhängige, verblindete Untersucher bewertet. Als primäre Outcomes wurden der ICRS-II Parameter „Generelles Assessment“, sowie die Typ II Kollagen positive Fläche designiert. Als explorative Outcomes wurden die verbleibenden ICRS-II Parameter, sowie die Typ I und Typ X Kollagen Deposition bewertet. Die Korrelation zwischen den Untersuchern wurde nach Pearson ermittelt. Zum Test auf Signifikanz der Gruppenunterschiede wurde ein lineares gemischtes Modell verwendet, welches einer mögliche Abhängigkeit beider Gelenke eines Tieres Rechnung trägt. Ergebnisse Qualitative Bewertung des Reparationsknorpels. Dreizehn Wochen nach der Intervention zeigten die meisten der BMP-2 behandelten Gelenke (4 von 6) und alle der IHH behandelten Gelenke (8 von 8) hyalin-artigen Reparationsknorpel, während alle GFP behandelten Kontrollgelenke (6 von 6) faserknorpel-artiges Reparationsgewebe zeigten. Zwei BMP-2 behandelten Gelenke zeigten eine ausgeprägte intraläsionale Knochenformation. Primäre Outcomes - ICRS-II „Generelles Assessment“ und Typ II Kollagen positive Fläche. IHH und BMP-2 behandelte Gelenke zeigten im Vergleich zu GFP höhere Punktzahlen in dem ICRS-II „Generelles Assessment“ Parameter: +33.0 (95% Konfidenzintervall: -0.4, +66.4) Punkte für IHH und +8.5 (-26.6, +43.7) Punkte für BMP-2. Beide Effekte erreichten nicht das Level statistischer Signifikanz (p=0.052 und 0.537). IHH erhöhte die Typ II Kollagen Deposition in der Defektregion, während BMP-2 Gelenke keinen Unterschied zu GFP Kontrollen zeigten: +18.7 (-4.5, +42.0) Punkte für IHH und +0.0 (-29.7, +29.8) Punkte für BMP-2. Die erhöhte Typ II Kollagendeposition erreichte nicht das konventionelle Level statistischer Signifikanz (p=0.093). Sekundäre Outcomes - ICRS-II Parameter. In dem Vergleich von BMP-2 mit GFP Kontrollen wurde in keinem der 12 untersuchten Parameter ein signifikanter Unterschied festgestellt. IHH Gentransfer resultierte hingegen in höheren Punktzahlen in allen untersuchten Parametern, wobei der Unterschied in 5 der 12 Parameter das Niveau statistischer Signifikanz erreichte. Ein um 21.5 Punkte (+3.6, +39.4) erhöhter Score wurde für den Parameter „Gewebemorphologie“ beobachtet, sowie +21.0 (+6.4, +35.7) für „Chondrozytäres Clustering“, +31.2 (+0.8, +61.5) für „Formation der Tidemark“, +17.3 (+0.2, +34.5) für „Abnorme Kalzifikation/Ossifikation“ und +35.0 (+4.6, +65.2) für das „Assessment der mittleren und tiefen Zone“. Sekundäre Outcomes - Marker chondrozytärer Hypertrophie. Eine perizelluläre Deposition von Typ X Kollagen wurde in allen Gruppen beobachtet. Eine deutlich gesteigerte Deposition wurde nur in den Gelenken beobachtet, die nach BMP2 Gentransfer eine ausgeprägte intraläsionale Knochenformation zeigten. Diskussion Das hier beschriebene Experiment stellt die erste Veröffentlichung der Wirksamkeit von IHH zur Verbesserung der histologischen Knorpelqualität von in-vivo therapierten Gelenkknorpeldefekten dar [175]. Die Hypothese, dass IHH zu einer verbesserten histologischen Knorpelqualität führt wurde bestätigt, während die Hypothese zu den positiven Effekten von BMP-2 wiederlegt wurde. IHH führte zu besseren Ergebnissen in allen Untersuchten Parametern, das Niveau statistischer Signifikanz wurde dabei in den Parametern „Gewebemorphologie“, „Chondrozytäres Clustering“, „Formation der Tidemark“, „Abnorme Kalzifikation/Ossifikation“ und „Assessment der mittleren und tiefen Zone“ erreicht. Das primäre Ziel dieses Experimentes war es, den „Proof of concept“ zu liefern, dass IHH auch in-vivo ein attraktiver Faktor für die Induktion der Chondrogenese darstellt. Das langfristige Ziel ist die Induktion der Chondrogenese unter Umgehung des TGF-β Signalweges zu erzielen, um eine folgende hypertrophe Differenzierung der Chondrozyten und die folgende Ossifikation des reparierten Defektes zu verhindern. Die Limitationen der Studie umfassen die ausschließlich histologische und immunhistochemische durchgeführte Bewertung der Knorpelqualität und eine eingeschränkte statistische Power. Ob IHH es vermag die hypertrophe Differenzierung zu umgehen und somit eine langfristige hyaline Knorpelreparation zu ermöglichen, ist in weiteren präklinischen Studien mit biochemischer und molekulargenetischer Analyse der Hypertrophie-Marker zu untersuchen. In Bezug auf den klinischen Einsatz zur Knorpelreparation erscheint der Einsatz der Wachstumsfaktoren als Protein auf funktionalisierten Matrices vielversprechend. BMP-2 wird aufgrund der hier beobachteten intraläsionalen Knochenformation nach BMP2 Gentransfer als nicht geeignet zur Unterstützung der Knorpelreparation in-vivo bewertet. N2 - Bone morphogenetic protein 2 (BMP-2, encoded by BMP2) and Indian hedgehog protein (IHH, encoded by IHH) are well known regulators of chondrogenesis and chondrogenic hypertrophy. Despite being a potent chondrogenic factor BMP-2 was observed to induce chondrocyte hypertrophy in osteoarthritis (OA), growth plate cartilage and adult mesenchymal stem cells (MSCs). IHH might induce chondrogenic differentiation through different intracellular signalling pathways without inducing subsequent chondrocyte hypertrophy. The primary objective of this study is to test the efficacy of direct BMP2 and IHH gene delivery via bone marrow coagulates to influence histological repair cartilage quality in vivo. Vector-laden autologous bone marrow coagulates with 10^11 adenoviral vector particles encoding BMP2, IHH or the Green fluorescent protein (GFP) were delivered to 3.2 mm osteochondral defects in the trochlea of rabbit knees. After 13 weeks the histological repair cartilage quality was assessed using the International Cartilage Repair Society (ICRS) II scoring system and the type II collagen positive area. IHH treatment resulted in superior histological repair cartilage quality than GFP controls in all of the assessed parameters (with P < 0.05 in five of 14 assessed parameters). Results of BMP2 treatment varied substantially, including severe intralesional bone formation in two of six joints after 13 weeks. In conclusion, IHH gene transfer is effective to improve repair cartilage quality in vivo, whereas BMP2 treatment, carried the risk intralesional bone formation. Therefore IHH protein can be considered as an attractive alternative candidate growth factor for further preclinical research and development towards improved treatments for articular cartilage defects. KW - Bone morphogenetic protein-2 KW - Indian Hedgehog KW - Gelenkknorpel KW - Gentherapie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142622 ER - TY - THES A1 - Brill [geb. Schubert], Sabine T1 - Blutzuckerverlauf, hormonelle Gegenregulation und kognitive Leistungsfähigkeit unter definierter körperlicher Belastung bei Patienten mit Morbus Addison und Diabetes mellitus Typ 1 CANDI – Studie: Counterregulatory Hormone Production in Adrenal Insufficiency and Diabetes Type I T1 - Bloodglucose,counterregulatory hormone production and cognition under defined exercise in patients with Diabetes mellitus type 1 and adrenal insufficiciency : CANDI-Study Counterregulatory Hormone Production in Adrenal Insufficiency and Diabetes Type I N2 - Spiroergometrische Dauerbelastung von Probanden mit Morbus Addison, Diabetes mellitus Typ 1, Polyglandulärem Autoimmunsyndrom Typ 2 (erkrankt sowohl an Mb. Addison als auch an Diabetes mellitus Typ1) und gesunden Kontrollen. Blutzuckerverlauf, hormonelle Gegenregulation und kognitive Leistungsfähigkeit vor und nach Belastung wurden gemessen. Während einer spiroergometrischen Dauerbelastung von 23 Minuten zeigte sich bei keinem der 10 Probanden mit ausschließlich Morbus Addison eine Neigung zur Hypoglykämie trotz fehlender Einnahme der mittäglichen Glukokortikoiddosis. Die Blutzucker blieben bei sämtlichen Probanden stabil und es zeigte sich sogar ein leichter Anstieg in der der Ergometrie anschließenden Nachbeobachtungsphase, eventuell als Hinweis auf eine mögliche Entwicklung einer Inulin-Resistenz. Auf die erwartungsgemäße Mindersekretion von Adrenalin zeigte sich eine ame ehesten kompensatorisch leicht höhere Sekretion von Noradrenalin als bei den nebennierengesunden Gruppen. Die übrige Sekretion gegenregulatorischer Hormone entsprach den Vergleichsgruppen. Die geleistete Arbeit am Fahrradergometer war bei den Probandengruppen mit Morbus Addison und APS 2 nahezu identisch, die Morbus Addison – Probanden traten sogar minimal weniger Ergometerwiderstand über die 15 Minuten Dauerbelastung. Dennoch zeigten die Probanden mit ausschließlich M. Addison einen adäquaten Anstieg der gegenregulatorischen Hormone ohne starke Schwankungen der Plasmaglukose, wohingegen es bei den Probanden mit APS 2, zu einem deutlichen Abfall der Plasmaglukose kam trotz deutlich niedrigerer Insulinkonzentrationen im Vergleich zur Probandengruppe mit ausschließlich Diabetes mellitus Typ 1. Die unzureichende Sekretion von Adrenalin, sowie der geringste Konzentrationsanstieg von Noradrenalin und dieser Untersuchung auch Wachstumshormon aller Probandengruppen verhinderte einen adäquaten Wiederanstieg des Blutzuckers. Die Probanden mit Nebennierenrindeninsuffizienz verzeichneten teils signifikant schlechtere Ergebnisse bei einem Konzentrations- und einem Kurzzeitgedächtnistest im direkten Anschluss an die Ergometrie im Vergleich mit den anderen Probandengruppen. Es gab keine relevanten Unterschiede der Testergebnisse in Ruhe. Die nebenniereninsuffizienten Probanden verbesserten sich jedoch signifikant weniger nach der Ergometrie bzw. zeigten nach dem Dauertest teils sogar schlechtere Leistungen. Die Probandengruppen mit Diabetes mellitus Typ 1 und die Kontrollgruppe zeigten eine erwartungsgemäße Verbesserung ihrer Leistung als Reaktion auf die vorherige körperliche Aktivität. Die Unterschiede in der kognitiven Performance sind am ehesten mit der unzureichenden Adrenalinsekretion und einem fehlenden akuten Cortisolanstieg der nebenniereninsuffizienten Probanden zu erklären. Die Probanden mit Nebennierenrindeninsuffizienz wurden mit signifikant niedrigeren Widerständen am Fahrradergometer belastet als die nebennierengesunden Probanden. Ein möglicher Erklärungsansatz hierfür könnte eine gewisse cortisonbedingte Myopathie sein. Dies verdeutlicht nochmals die Notwendigkeit der Optimierung der Glukokortikoidsubstitutionstherapie. Neue Substitutionsregime sollten möglichst die physiologische circadiane Sekretionsrhythmik besser imitieren und im Optimalfall die Tagesdosis an Hydrocortison reduzieren, um glukokortikoidbedingte Nebenwirkungen wie Myopathie und Insulin-Resistenz zu reduzieren. Die Probanden mit polyglandulärem Autoimmunsyndrom Typ 2, welche sowohl an Morbus Addison als auch an Diabetes mellitus Typ 1 leiden, müssen im Rahmen von Patientenschulungen besonders auf das Risiko von Hypoglykämien bei vermehrter körperlicher Aktivität hingewiesen werden. Patienten mit Insulinpumpe sollten das Ausschalten währenddessen erwägen und darüber hinaus besondere Aufmerksamkeit auf die Einnahme einer zusätzlichen Kohlenhydrateinheit für den Sport walten lassen. Eine zusätzliche Einnahme des Glukokortikoids ist in diesem Zusammenhang nicht sinnvoll. [31] Ein vor dem Sport beispielsweise inhalativ appliziertes Epinephrinpräparat wäre eine mögliche Strategie zur Verbesserung des Plasmaglukose-Outcomes nach sportlicher Betätigung auf moderatem bzw. hohem Anstrengungslevel bei Patienten mit Morbus Addison und Diabetes mellitus Typ 1 und sollte Gegenstand weiterführender Studien sein. N2 - Bloodglucose,counterregulatory hormone production and cognition under defined exercise in patients with Diabetes mellitus type 1 and adrenal insufficiciency : CANDI-Study Counterregulatory Hormone Production in Adrenal Insufficiency and Diabetes Type I KW - Nebenniereninsuffizienz KW - Diabetes mellitusTyp 1 KW - Spiroergometrie KW - Blutzuckerverlauf KW - Kognition KW - adrenal KW - diabetes typ 1 KW - cognition Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142646 ER - TY - THES A1 - Kuck, Laura Katharina T1 - Nabelhernien im Kindesalter - eine retrospektive Analyse T1 - Umbilical hernia in children - a retrospective analysis N2 - Eine Nabelhernie stellt im Kindesalter eine angeborene Faszienlücke im Bereich der ventralen Bauchwand dar. Material und Methoden: Über einen Zeitraum von über zehn Jahren wurden in der kinderchirurgischen Abteilung der Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie der Universität Würzburg 518 Patienten mit Nabelhernien operiert, wobei 499 Patienten nach Ausschlusskriterien in der Studie evaluiert wurden. Ergebnisse: Durch die Direktnaht und Sicherung mittels einer zweiten Fasziennaht nach semizirkulärer, subumbilicaler Inzision nach Spitzy konnte eine niedrige Rezidivquote von 1% (n=5 von n=499) erzielt werden. Die jungen Patienten waren im Durchschnitt 33,8 Monate alt und zu 44,1% weiblich und zu 55,9% männlich. Im Vergleich hierzu lag die Rezidivquote in der Erwachsenenchirurgie nach Direktnaht bei 12,9% (n=4 von n=31 Direktnähten bei n=62 Nabelhernien). Das Durchschnittsalter der erwachsenen Patienten betrug 54,5 Jahre; 32,3% waren weiblich, 67,7% männlich. Schlussfolgerung: Aufgrund der Studienergebnisse stellt die Nabelhernienversorgung im Kindesalter durch Direktnaht und Zugang nach Spitzy das Mittel der Wahl und den Goldstandard dar, sobald dringliche Operationsindikationen wie eine Größenprogredienz, Schmerzsymptomatik oder Inkarzerationszeichen vorliegen. N2 - Umbilical hernia in children present a connatal gap in the adominal fascia localized in the ventral abdominal wall. Material and methods: In over 10 years 518 young patients with umbilical hernia were treated surgically in the University Clinic and Policlinic for General-, Visceral-, Vascular- and Child-Surgery Würzburg. After exclusion criteria, 499 patients were evaluated in the study. Results: By the use of direct suture and security measures such as a second fascia suture after semicircular, subumbilical incision after Spitzy, a lowest recurrence rate of 1% (n=5 out of n=499) could be achieved. The young patients had an average age of 33.8 months and were 44.1% female and 55.9% male. In comparison the recurrence rate in adults is 12.9% (n=4 out of n=31 direct sutures out of n=62 ubilical hernia patients) after direct suture. The average age of adult patients was 54.5 years; 32.3% were female, 67.7% male. Conclusion: As it is confirmed in the current study, umbilical herniotomy in children by direct suture and access after Spitzy is the agent of choice and presents the gold standard, as soon as urgent surgery indications such as progression of gapsize, painful symptomatology or signs of incarceration are present. KW - Nabelhernie KW - Kinderchirurgie KW - umbilical hernia KW - pediatric surgery Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-141424 ER -