TY - JOUR A1 - Gruschwitz, Philipp A1 - Hartung, Viktor A1 - Ergün, Süleyman A1 - Peter, Dominik A1 - Lichthardt, Sven A1 - Huflage, Henner A1 - Hendel, Robin A1 - Pannenbecker, Pauline A1 - Augustin, Anne Marie A1 - Kunz, Andreas Steven A1 - Feldle, Philipp A1 - Bley, Thorsten Alexander A1 - Grunz, Jan-Peter T1 - Comparison of ultrahigh and standard resolution photon-counting CT angiography of the femoral arteries in a continuously perfused in vitro model JF - European Radiology Experimental N2 - Background With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies. Methods After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode. Images were reconstructed with dedicated convolution kernels (soft: Body-vascular (Bv)48; sharp: Bv60; ultrasharp: Bv76). Six radiologists evaluated the image quality by means of a pairwise forced-choice comparison tool. Kendall’s concordance coefficient (W) was calculated to quantify interrater agreement. Image quality was further assessed by measuring intraluminal attenuation and image noise as well as by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR). Results UHR yielded lower noise than SR for identical reconstructions with kernels ≥ Bv60 (p < 0.001). UHR scans exhibited lower intraluminal attenuation compared to SR (Bv60: 406.4 ± 25.1 versus 418.1 ± 30.1 HU; p < 0.001). Irrespective of scan mode, SNR and CNR decreased while noise increased with sharper kernels but UHR scans were objectively superior to SR nonetheless (Bv60: SNR 25.9 ± 6.4 versus 20.9 ± 5.3; CNR 22.7 ± 5.8 versus 18.4 ± 4.8; p < 0.001). Notably, UHR scans were preferred in subjective assessment when images were reconstructed with the ultrasharp Bv76 kernel, whereas SR was rated superior for Bv60. Interrater agreement was high (W = 0.935). Conclusions Combinations of UHR scan mode and ultrasharp convolution kernel are able to exploit the full image quality potential in photon-counting CT angiography of the femoral arteries. Relevance statement The UHR scan mode offers improved image quality and may increase diagnostic accuracy in CT angiography of the peripheral arterial runoff when optimized reconstruction parameters are chosen. Key points • UHR photon-counting CT improves image quality in combination with ultrasharp convolution kernels. • UHR datasets display lower image noise compared with identically reconstructed standard resolution scans. • Scans in UHR mode show decreased intraluminal attenuation compared with standard resolution imaging. KW - CT angiography KW - femoral arteries KW - photon-counting computed tomography (CT) KW - small pixel effect KW - ultrahigh resolution Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357905 VL - 7 ER - TY - JOUR A1 - Gruschwitz, Philipp A1 - Hartung, Viktor A1 - Kleefeldt, Florian A1 - Peter, Dominik A1 - Lichthardt, Sven A1 - Huflage, Henner A1 - Grunz, Jan-Peter A1 - Augustin, Anne Marie A1 - Ergün, Süleyman A1 - Bley, Thorsten Alexander A1 - Petritsch, Bernhard T1 - Continuous extracorporeal femoral perfusion model for intravascular ultrasound, computed tomography and digital subtraction angiography JF - PLoS One N2 - Objectives We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS). Methods The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers. In all specimens, the common femoral and popliteal arteries were prepared, introducer sheaths inserted, and perfusion established by a peristaltic pump. Subsequently, we performed CTA and bilateral DSA in five cadavers and IVUS on both legs of four donors. Examination time without unintentional interruption was measured both with and without non-contrast planning CT. Percutaneous transluminal angioplasty and stenting was performed by two interventional radiologists on nine extremities (five donors) using a broad spectrum of different intravascular devices. Results The perfusion of the upper leg arteries was successfully established in all fresh-frozen but not in the formalin-fixed cadaver. The experimental setup generated a stable circulation in each procedure (ten upper legs) for a period of more than six hours. Images acquired with CT, DSA and IVUS offered a realistic impression and enabled the sufficient visualization of all examined vessel segments. Arterial cannulating, percutaneous transluminal angioplasty as well as stent deployment were feasible in a way that is comparable to a vascular intervention in vivo. The perfusion model allowed for introduction and testing of previously not used devices. Conclusions The continuous femoral perfusion model can be established with moderate effort, works stable, and is utilizable for medical imaging of the peripheral arterial system using CTA, DSA and IVUS. Therefore, it appears suitable for research studies, developing skills in interventional procedures and testing of new or unfamiliar vascular devices. KW - continuous extracorporeal femoral perfusion model KW - novel human cadaveric perfusion model KW - computed tomography angiography (CTA) KW - digital subtraction angiography (DSA) KW - intravascular ultrasound (IVUS) Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-350136 SN - 1932-6203 VL - 18 IS - 5 ER - TY - JOUR A1 - Madrahimov, Nodir A1 - Mutsenko, Vitalii A1 - Natanov, Ruslan A1 - Radaković, Dejan A1 - Klapproth, André A1 - Hassan, Mohamed A1 - Rosenfeldt, Mathias A1 - Kleefeldt, Florian A1 - Aleksic, Ivan A1 - Ergün, Süleyman A1 - Otto, Christoph A1 - Leyh, Rainer G. A1 - Bening, Constanze T1 - Multiorgan recovery in a cadaver body using mild hypothermic ECMO treatment in a murine model JF - Intensive Care Medicine Experimental N2 - Background Transplant candidates on the waiting list are increasingly challenged by the lack of organs. Most of the organs can only be kept viable within very limited timeframes (e.g., mere 4–6 h for heart and lungs exposed to refrigeration temperatures ex vivo). Donation after circulatory death (DCD) using extracorporeal membrane oxygenation (ECMO) can significantly enlarge the donor pool, organ yield per donor, and shelf life. Nevertheless, clinical attempts to recover organs for transplantation after uncontrolled DCD are extremely complex and hardly reproducible. Therefore, as a preliminary strategy to fulfill this task, experimental protocols using feasible animal models are highly warranted. The primary aim of the study was to develop a model of ECMO-based cadaver organ recovery in mice. Our model mimics uncontrolled organ donation after an “out-of-hospital” sudden unexpected death with subsequent “in-hospital” cadaver management post-mortem. The secondary aim was to assess blood gas parameters, cardiac activity as well as overall organ state. The study protocol included post-mortem heparin–streptokinase administration 10 min after confirmed death induced by cervical dislocation under full anesthesia. After cannulation, veno-arterial ECMO (V–A ECMO) was started 1 h after death and continued for 2 h under mild hypothermic conditions followed by organ harvest. Pressure- and flow-controlled oxygenated blood-based reperfusion of a cadaver body was accompanied by blood gas analysis (BGA), electrocardiography, and histological evaluation of ischemia–reperfusion injury. For the first time, we designed and implemented, a not yet reported, miniaturized murine hemodialysis circuit for the treatment of severe hyperkalemia and metabolic acidosis post-mortem. Results BGA parameters confirmed profound ischemia typical for cadavers and incompatible with normal physiology, including extremely low blood pH, profound negative base excess, and enormously high levels of lactate. Two hours after ECMO implantation, blood pH values of a cadaver body restored from < 6.5 to 7.3 ± 0.05, pCO2 was lowered from > 130 to 41.7 ± 10.5 mmHg, sO2, base excess, and HCO3 were all elevated from below detection thresholds to 99.5 ± 0.6%, − 4 ± 6.2 and 22.0 ± 6.0 mmol/L, respectively (Student T test, p < 0.05). A substantial decrease in hyperlactatemia (from > 20 to 10.5 ± 1.7 mmol/L) and hyperkalemia (from > 9 to 6.9 ± 1.0 mmol/L) was observed when hemodialysis was implemented. On balance, the first signs of regained heart activity appeared on average 10 min after ECMO initiation without cardioplegia or any inotropic and vasopressor support. This was followed by restoration of myocardial contractility with a heart rate of up to 200 beats per minute (bpm) as detected by an electrocardiogram (ECG). Histological examinations revealed no evidence of heart injury 3 h post-mortem, whereas shock-specific morphological changes relevant to acute death and consequent cardiac/circulatory arrest were observed in the lungs, liver, and kidney of both control and ECMO-treated cadaver mice. Conclusions Thus, our model represents a promising approach to facilitate studying perspectives of cadaveric multiorgan recovery for transplantation. Moreover, it opens new possibilities for cadaver organ treatment to extend and potentiate donation and, hence, contribute to solving the organ shortage dilemma. KW - extracorporeal membrane oxygenation KW - cadaver multiorgan preservation KW - mild hypothermia KW - post-mortem heart recovery Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357381 VL - 11 ER - TY - JOUR A1 - Kollmann, Catherine A1 - Buerkert, Hannah A1 - Meir, Michael A1 - Richter, Konstantin A1 - Kretzschmar, Kai A1 - Flemming, Sven A1 - Kelm, Matthias A1 - Germer, Christoph-Thomas A1 - Otto, Christoph A1 - Burkard, Natalie A1 - Schlegel, Nicolas T1 - Human organoids are superior to cell culture models for intestinal barrier research JF - Frontiers in Cell and Developmental Biology N2 - Loss of intestinal epithelial barrier function is a hallmark in digestive tract inflammation. The detailed mechanisms remain unclear due to the lack of suitable cell-based models in barrier research. Here we performed a detailed functional characterization of human intestinal organoid cultures under different conditions with the aim to suggest an optimized ex-vivo model to further analyse inflammation-induced intestinal epithelial barrier dysfunction. Differentiated Caco2 cells as a traditional model for intestinal epithelial barrier research displayed mature barrier functions which were reduced after challenge with cytomix (TNFα, IFN-γ, IL-1ß) to mimic inflammatory conditions. Human intestinal organoids grown in culture medium were highly proliferative, displayed high levels of LGR5 with overall low rates of intercellular adhesion and immature barrier function resembling conditions usually found in intestinal crypts. WNT-depletion resulted in the differentiation of intestinal organoids with reduced LGR5 levels and upregulation of markers representing the presence of all cell types present along the crypt-villus axis. This was paralleled by barrier maturation with junctional proteins regularly distributed at the cell borders. Application of cytomix in immature human intestinal organoid cultures resulted in reduced barrier function that was accompanied with cell fragmentation, cell death and overall loss of junctional proteins, demonstrating a high susceptibility of the organoid culture to inflammatory stimuli. In differentiated organoid cultures, cytomix induced a hierarchical sequence of changes beginning with loss of cell adhesion, redistribution of junctional proteins from the cell border, protein degradation which was accompanied by loss of epithelial barrier function. Cell viability was observed to decrease with time but was preserved when initial barrier changes were evident. In summary, differentiated intestinal organoid cultures represent an optimized human ex-vivo model which allows a comprehensive reflection to the situation observed in patients with intestinal inflammation. Our data suggest a hierarchical sequence of inflammation-induced intestinal barrier dysfunction starting with loss of intercellular adhesion, followed by redistribution and loss of junctional proteins resulting in reduced barrier function with consecutive epithelial death. KW - intestinal epithelial barrier KW - Caco2 cells KW - intestinal organoids KW - enteroids KW - gut barrier KW - inflammatory cell model KW - inflammation Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357317 SN - 2296-634X VL - 11 ER - TY - JOUR A1 - Döhler, Ida A1 - Röder, Daniel A1 - Schlesinger, Tobias A1 - Nassen, Christian Alexander A1 - Germer, Christoph-Thomas A1 - Wiegering, Armin A1 - Lock, Johan Friso T1 - Risk-adjusted perioperative bridging anticoagulation reduces bleeding complications without increasing thromboembolic events in general and visceral surgery JF - BMC Anesthesiology N2 - Background Perioperative bridging of oral anticoagulation increases the risk of bleeding complications after elective general and visceral surgery. The aim of this study was to explore, whether an individual risk-adjusted bridging regimen can reduce bleeding events, while still protecting against thromboembolic events. Methods We performed a quality improvement study comparing bridging parameters and postoperative outcomes before (period 1) and after implementation (period 2) of a new risk-adjusted bridging regimen. The primary endpoint of the study was overall incidence of postoperative bleeding complications during 30 days postoperatively. Secondary endpoints were major postoperative bleeding, minor bleeding, thromboembolic events, postoperative red blood cell transfusion, perioperative length-of-stay (LOS) and in-hospital mortality. Results A total of 263 patients during period 1 and 271 patients during period 2 were compared. The included elective operations covered the entire field of general and visceral surgery. The overall incidence of bleeding complications declined from 22.1% during period 1 to 10.3% in period 2 (p < 0.001). This reduction affected both major as well as minor bleeding events (8.4% vs. 4.1%; p = 0.039; 13.7% vs. 6.3%; p = 0.004). The incidence of thromboembolic events remained low (0.8% vs. 1.1%). No changes in mortality or length-of-stay were observed. Conclusion It is important to balance the individual thromboembolic and bleeding risks in perioperative bridging management. The risk adjusted bridging regimen reduces bleeding events in general and visceral surgery while the risk of thromboembolism remains comparably low. KW - low-molecular heparin KW - atrial fibrillation KW - postoperative bleeding KW - thromboembolism KW - anticoagulation KW - bridging Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357305 VL - 23 ER - TY - JOUR A1 - Gruschwitz, Philipp A1 - Hartung, Viktor A1 - Kleefeldt, Florian A1 - Ergün, Süleyman A1 - Lichthardt, Sven A1 - Huflage, Henner A1 - Hendel, Robin A1 - Kunz, Andreas Steven A1 - Pannenbecker, Pauline A1 - Kuhl, Philipp Josef A1 - Augustin, Anne Marie A1 - Bley, Thorsten Alexander A1 - Petritsch, Bernhard A1 - Grunz, Jan-Peter T1 - Standardized assessment of vascular reconstruction kernels in photon-counting CT angiographies of the leg using a continuous extracorporeal perfusion model JF - Scientific Reports N2 - This study evaluated the influence of different vascular reconstruction kernels on the image quality of CT angiographies of the lower extremity runoff using a 1st-generation photon-counting-detector CT (PCD-CT) compared with dose-matched examinations on a 3rd-generation energy-integrating-detector CT (EID-CT). Inducing continuous extracorporeal perfusion in a human cadaveric model, we performed CT angiographies of eight upper leg arterial runoffs with radiation dose-equivalent 120 kVp acquisition protocols (CTDIvol 5 mGy). Reconstructions were executed with different vascular kernels, matching the individual modulation transfer functions between scanners. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were computed to assess objective image quality. Six radiologists evaluated image quality subjectively using a forced-choice pairwise comparison tool. Interrater agreement was determined by calculating Kendall’s concordance coefficient (W). The intraluminal attenuation of PCD-CT images was significantly higher than of EID-CT (414.7 ± 27.3 HU vs. 329.3 ± 24.5 HU; p < 0.001). Using comparable kernels, image noise with PCD-CT was significantly lower than with EID-CT (p ≤ 0.044). Correspondingly, SNR and CNR were approximately twofold higher for PCD-CT (p < 0.001). Increasing the spatial frequency for PCD-CT reconstructions by one level resulted in similar metrics compared to EID-CT (CNRfat; EID-CT Bv49: 21.7 ± 3.7 versus PCD-CT Bv60: 21.4 ± 3.5). Overall image quality of PCD-CTA achieved ratings superior to EID-CTA irrespective of the used reconstruction kernels (best: PCD-CT Bv60; worst: EID-CT Bv40; p < 0.001). Interrater agreement was good (W = 0.78). Concluding, PCD-CT offers superior intraluminal attenuation, SNR, and CNR compared to EID-CT in angiographies of the upper leg arterial runoff. Combined with improved subjective image quality, PCD-CT facilitates the use of sharper convolution kernels and ultimately bears the potential of improved vascular structure assessability. KW - experimental models of disease KW - preclinical research KW - translational research Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357912 VL - 13 ER - TY - JOUR A1 - Hankir, Mohammed K. A1 - Patt, Marianne A1 - Patt, Jörg T. W. A1 - Becker, Georg A. A1 - Rullmann, Michael A1 - Kranz, Mathias A1 - Deuther-Conrad, Winnie A1 - Schischke, Kristin A1 - Seyfried, Florian A1 - Brust, Peter A1 - Hesse, Swen A1 - Sabri, Osama A1 - Krügel, Ute A1 - Fenske, Wiebke T1 - Suppressed fat appetite after Roux-en-Y gastric bypass surgery associates with reduced brain mu-opioid receptor availability in diet-induced obese male rats JF - Frontiers in Neuroscience N2 - Brain μ-opioid receptors (MORs) stimulate high-fat (HF) feeding and have been implicated in the distinct long term outcomes on body weight of bariatric surgery and dieting. Whether alterations in fat appetite specifically following these disparate weight loss interventions relate to changes in brain MOR signaling is unknown. To address this issue, diet-induced obese male rats underwent either Roux-en-Y gastric bypass (RYGB) or sham surgeries. Postoperatively, animals were placed on a two-choice diet consisting of low-fat (LF) and HF food and sham-operated rats were further split into ad libitum fed (Sham-LF/HF) and body weight-matched (Sham-BWM) to RYGB groups. An additional set of sham-operated rats always only on a LF diet (Sham-LF) served as lean controls, making four experimental groups in total. Corresponding to a stage of weight loss maintenance for RYGB rats, two-bottle fat preference tests in conjunction with small-animal positron emission tomography (PET) imaging studies with the selective MOR radioligand [\(^{11}\)C]carfentanil were performed. Brains were subsequently collected and MOR protein levels in the hypothalamus, striatum, prefrontal cortex and orbitofrontal cortex were analyzed by Western Blot. We found that only the RYGB group presented with intervention-specific changes: having markedly suppressed intake and preference for high concentration fat emulsions, a widespread reduction in [\(^{11}\)C]carfentanil binding potential (reflecting MOR availability) in various brain regions, and a downregulation of striatal and prefrontal MOR protein levels compared to the remaining groups. These findings suggest that the suppressed fat appetite caused by RYGB surgery is due to reduced brain MOR signaling, which may contribute to sustained weight loss unlike the case for dieting. KW - bariatric surgery KW - caloric-restriction KW - fat appetite KW - Brain μ-opioid receptors KW - positron emission tomography imaging Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-181130 VL - 10 ER - TY - JOUR A1 - Silwedel, Christine A1 - Hütten, Matthias C. A1 - Speer, Christian P. A1 - Härtel, Christoph A1 - Haarmann, Axel A1 - Henrich, Birgit A1 - Tijssen, Maud P. M. A1 - Alnakhli, Abdullah Ahmed A1 - Spiller, Owen B. A1 - Schlegel, Nicolas A1 - Seidenspinner, Silvia A1 - Kramer, Boris W. A1 - Glaser, Kirsten T1 - Ureaplasma-driven neonatal neuroinflammation: novel insights from an ovine model JF - Cellular and Molecular Neurobiology N2 - Ureaplasma species (spp.) are considered commensals of the adult genitourinary tract, but have been associated with chorioamnionitis, preterm birth, and invasive infections in neonates, including meningitis. Data on mechanisms involved in Ureaplasma-driven neuroinflammation are scarce. The present study addressed brain inflammatory responses in preterm lambs exposed to Ureaplasma parvum (UP) in utero. 7 days after intra-amniotic injection of UP (n = 10) or saline (n = 11), lambs were surgically delivered at gestational day 128–129. Expression of inflammatory markers was assessed in different brain regions using qRT-PCR and in cerebrospinal fluid (CSF) by multiplex immunoassay. CSF was analyzed for UP presence using ureB-based real-time PCR, and MRI scans documented cerebral white matter area and cortical folding. Cerebral tissue levels of atypical chemokine receptor (ACKR) 3, caspases 1-like, 2, 7, and C–X–C chemokine receptor (CXCR) 4 mRNA, as well as CSF interleukin-8 protein concentrations were significantly increased in UP-exposed lambs. UP presence in CSF was confirmed in one animal. Cortical folding and white matter area did not differ among groups. The present study confirms a role of caspases and the transmembrane receptors ACKR3 and CXCR4 in Ureaplasma-driven neuroinflammation. Enhanced caspase 1-like, 2, and 7 expression may reflect cell death. Increased ACKR3 and CXCR4 expression has been associated with inflammatory central nervous system (CNS) diseases and impaired blood–brain barrier function. According to these data and previous in vitro findings from our group, we speculate that Ureaplasma-induced caspase and receptor responses affect CNS barrier properties and thus facilitate neuroinflammation. KW - Ureaplasma parvum KW - CNS integrity KW - neonatal meningitis KW - preterm birth KW - immaturity KW - animal model Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324285 VL - 43 IS - 2 ER - TY - JOUR A1 - Baur, Johannes A1 - Ramser, Michaela A1 - Keller, Nicola A1 - Muysoms, Filip A1 - Dörfer, Jörg A1 - Wiegering, Armin A1 - Eisner, Lukas A1 - Dietz, Ulrich A. T1 - Robotic hernia repair II. English version BT - Robotic primary ventral and incisional hernia repair (rv‑TAPP and r‑Rives or r‑TARUP). Video report and results of a series of 118 patients JF - Der Chirurg N2 - Endoscopic management of umbilical and incisional hernias has adapted to the limitations of conventional laparoscopic instruments over the past 30 years. This includes the development of meshes for intraperitoneal placement (intraperitoneal onlay mesh, IPOM), with antiadhesive coatings; however, adhesions do occur in a significant proportion of these patients. Minimally invasive procedures result in fewer perioperative complications, but with a slightly higher recurrence rate. With the ergonomic resources of robotics, which offers angled instruments, it is now possible to implant meshes in a minimally invasively manner in different abdominal wall layers while achieving morphologic and functional reconstruction of the abdominal wall. This video article presents the treatment of ventral and incisional hernias with mesh implantation into the preperitoneal space (robot-assisted transabdominal preperitoneal ventral hernia repair, r‑ventral TAPP) as well as into the retrorectus space (r-Rives and robotic transabdominal retromuscular umbilical prosthetic repair, r‑TARUP, respectively). The results of a cohort study of 118 consecutive patients are presented and discussed with regard to the added value of the robotic technique in extraperitoneal mesh implantation and in the training of residents. N2 - Die endoskopische Versorgung von Umbilikal- und Inzisionalhernien hat sich in den vergangenen 30 Jahren an die Limitationen der konventionellen laparoskopischen Instrumente angepasst. Dazu gehört die Entwicklung von Netzen für die intraperitoneale Lage (intraperitoneales Onlay-Mesh, IPOM) mit antiadhäsiven Beschichtungen; allerdings kommt es bei einem beträchtlichen Teil dieser Patienten doch zu Adhäsionen. Minimal-invasive Verfahren führen zu weniger perioperativen Komplikationen, bei einer etwas höheren Rezidivrate. Mit den ergonomischen Ressourcen der Robotik, die abgewinkelte Instrumente anbietet, besteht erstmals die Möglichkeit, Netze minimal-invasiv in unterschiedliche Bauchdeckenschichten zu implantieren und gleichzeitig eine morphologische und funktionelle Rekonstruktion der Bauchdecke zu erreichen. In diesem Videobeitrag wird die Versorgung von Ventral- und Inzisionalhernien mit Netzimplantation in den präperitonealen Raum (robotische ventrale transabdominelle präperitoneale Patchplastik, rv-TAPP) sowie in den retrorektalen Raum (r-Rives bzw. robotische transabdominelle retromuskuläre umbilikale Patchplastik [r-TARUP]) präsentiert. Es werden die Ergebnisse einer Kohortenstudie an 118 konsekutiven Patienten vorgestellt und im Hinblick auf den Mehrwert der robotischen Technik in der Extraperitonealisierung der Netze und in der Weiterbildung diskutiert. T2 - Robotische Hernienchirurgie II: Robotische primär ventrale und inzisionale Hernienversorgung (rv-TAPP und r-Rives/r-TARUP). Videobeitrag und Ergebnisse einer Kohortenstudie an 118 Patienten KW - umbilical hernia KW - incisional hernia KW - primary ventral hernia KW - minimally invasive KW - retrorectus mesh KW - linea alba KW - Umbilikalhernie KW - Inzisionalhernie KW - primär ventrale Hernie KW - Minimalinvasiv KW - Retrorektus Netz KW - Linea alba Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-323866 VL - 92 IS - Suppl 1 ER - TY - JOUR A1 - Dewulf, Maxime A1 - Dietz, Ulrich A. A1 - Montgomery, Agneta A1 - Pauli, Eric M. A1 - Marturano, Matthew N. A1 - Ayuso, Sullivan A. A1 - Augenstein, Vedra A. A1 - Lambrecht, Jan R. A1 - Köhler, Gernot A1 - Keller, Nicola A1 - Wiegering, Armin A1 - Muysoms, Filip T1 - Robotic hernia surgery IV. English version BT - Robotic parastomal hernia repair. Video report and preliminary results JF - Chirurgie N2 - The surgical treatment of parastomal hernias is considered complex and is known to be prone to complications. Traditionally, this condition was treated using relocation techniques or local suture repairs. Since then, several mesh-based techniques have been proposed and are nowadays used in minimally invasive surgery. Since the introduction of robot-assisted surgery to the field of abdominal wall surgery, several adaptations to these techniques have been made, which may significantly improve patient outcomes. In this contribution, we provide an overview of available techniques in robot-assisted parastomal hernia repair. Technical considerations and preliminary results of robot-assisted modified Sugarbaker repair, robot-assisted Pauli technique, and minimally invasive use of a funnel-shaped mesh in the treatment of parastomal hernias are presented. Furthermore, challenges in robot-assisted ileal conduit parastomal hernia repair are discussed. These techniques are illustrated by photographic and video material. Besides providing a comprehensive overview of robot-assisted parastomal hernia repair, this article focuses on the specific advantages of robot-assisted techniques in the treatment of this condition. N2 - Die chirurgische Behandlung parastomaler Hernien gilt als komplex und ist bekanntermaßen komplikationsträchtig. In der Vergangenheit wurden diese Hernien durch die Relokation des Stomas oder Nahtverfahren der Austrittstelle versorgt. In den letzten Jahren wurden verschiedene netzbasierte Techniken vorgeschlagen, die heute in der minimal-invasiven Chirurgie eingesetzt werden. Mit der Verbreitung der roboterassistierten Hernienchirurgie wurden die Netzverfahren weiterentwickelt und die Ergebnisse für die Patienten erheblich verbessert. In diesem Beitrag wird ein Überblick über die verfügbaren Techniken der roboterassistierten Versorgung parastomaler Hernien präsentiert. Es werden technische Überlegungen und erste Ergebnisse des roboterassistierten modifizierten Sugarbaker-Verfahrens, der roboterassistierten Pauli-Technik und der Verwendung des trichterförmigen Netzes IPST vorgestellt. Darüber hinaus werden die Herausforderungen bei der roboterassistierten Versorgung parastomaler Hernien am Ileum-Conduit diskutiert. Die Operationstechniken werden durch Foto- und Videomaterial veranschaulicht. T2 - Robotische Hernienchirurgie Teil IV: Roboterassistierte endoskopische parastomale Hernienversorgung. Videobericht und Ergebnisse KW - parastomal hernia KW - Ileal conduit KW - Pauli procedure KW - funnel mesh (IPST) KW - modified Sugarbaker technique KW - Parastomale Hernie KW - Ileum-Conduit KW - Pauli-Verfahren KW - Trichternetz (IPST) KW - Modifizierte Sugarbaker-Technik Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-323875 VL - 93 IS - Suppl 2 ER -