TY - JOUR A1 - Chen, Xinyu A1 - Werner, Rudolf A. A1 - Javadi, Mehrbod S. A1 - Maya, Yoshifumi A1 - Decker, Michael A1 - Lapa, Constantin A1 - Herrmann, Ken A1 - Higuchi, Takahiro T1 - Radionuclide imaging of neurohormonal system of the heart JF - Theranostics N2 - Heart failure is one of the growing causes of death especially in developed countries due to longer life expectancy. Although many pharmacological and instrumental therapeutic approaches have been introduced for prevention and treatment of heart failure, there are still limitations and challenges. Nuclear cardiology has experienced rapid growth in the last few decades, in particular the application of single photon emission computed tomography (SPECT) and positron emission tomography (PET), which allow non-invasive functional assessment of cardiac condition including neurohormonal systems involved in heart failure; its application has dramatically improved the capacity for fundamental research and clinical diagnosis. In this article, we review the current status of applying radionuclide technology in non-invasive imaging of neurohormonal system in the heart, especially focusing on the tracers that are currently available. A short discussion about disadvantages and perspectives is also included. KW - SPECT KW - radiotracer KW - heart failure KW - cardiac neurohormonal system KW - nuclear cardiology KW - PET Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-149205 VL - 5 IS - 6 ER - TY - JOUR A1 - Chen, Xinyu A1 - Kudo, Takashi A1 - Lapa, Constantin A1 - Buck, Andreas A1 - Higuchi, Takahiro T1 - Recent advances in radiotracers targeting norepinephrine transporter: structural development and radiolabeling improvements JF - Journal of Neural Transmission N2 - The norepinephrine transporter (NET) is a major target for the evaluation of the cardiac sympathetic nerve system in patients with heart failure and Parkinson's disease. It is also used in the therapeutic applications against certain types of neuroendocrine tumors, as exemplified by the clinically used \(^{123/131}\)I-MIBG as theranostic single-photon emission computed tomography (SPECT) agent. With the development of more advanced positron emission tomography (PET) technology, more radiotracers targeting NET have been reported, with superior temporal and spatial resolutions, along with the possibility of functional and kinetic analysis. More recently, fluorine-18-labelled NET tracers have drawn increasing attentions from researchers, due to their longer radiological half-life relative to carbon-11 (110 min vs. 20 min), reduced dependence on on-site cyclotrons, and flexibility in the design of novel tracer structures. In the heart, certain NET tracers provide integral diagnostic information on sympathetic innervation and the nerve status. In the central nervous system, such radiotracers can reveal NET distribution and density in pathological conditions. Most radiotracers targeting cardiac NET-function for the cardiac application consistent of derivatives of either norepinephrine or MIBG with its benzylguanidine core structure, e.g. \(^{11}\)C-HED and \(^{18}\)F-LMI1195. In contrast, all NET tracers used in central nervous system applications are derived from clinically used antidepressants. Lastly, possible applications of NET as selective tracers over organic cation transporters (OCTs) in the kidneys and other organs controlled by sympathetic nervous system will also be discussed. KW - norepinephrine transporter KW - benzylguanidine KW - phenethylguanidine KW - antidepressant KW - organic cation transporter Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-241148 VL - 127 ER - TY - JOUR A1 - Buder, Kristina A1 - Lapa, Constantin A1 - Kreissl, Michael C. A1 - Schirbel, Andreas A1 - Herrmann, Ken A1 - Schnack, Alexander A1 - Bröcker, Eva-Bettina A1 - Goebeler, Matthias A1 - Buck, Andreas K. A1 - Becker, Jürgen C. T1 - "Somatostatin receptor expression in Merkel cell carcinoma as target for molecular imaging" N2 - Background Merkel cell carcinoma (MCC) is a rare cutaneous neoplasm with increasing incidence, aggressive behavior and poor prognosis. Somatostatin receptors (SSTR) are expressed in MCC and represent a potential target for both imaging and treatment. Methods To non-invasively assess SSTR expression in MCC using PET and the radiotracers [68Ga]DOTA-D-Phe1-Tyr3-octreotide (DOTATOC) or -octreotate (DOTATATE) as surrogate for tumor burden. In 24 patients with histologically proven MCC SSTR-PET was performed and compared to results of computed tomography (CT). Results SSTR-PET detected primary and metastatic MCC lesions. On a patient-based analysis, sensitivity of SSTR-PET was 73% for nodal metastases, 100% for bone, and 67% for soft-tissue metastases, respectively. Notably, brain metastases were initially detected by SSTR-PET in 2 patients, whereas liver and lung metastases were diagnosed exclusively by CT. SSTR-PET showed concordance to CT results in 20 out of 24 patients. Four patients (17%) were up-staged due to SSTR-PET and patient management was changed in 3 patients (13%). Conclusion SSTR-PET showed high sensitivity for imaging bone, soft tissue and brain metastases, and particularly in combination with CT had a significant impact on clinical stage and patient management. KW - Merkel cell carcinoma KW - Molecular imaging KW - Somatostatin receptor expression KW - Positron emission tomography Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-110326 ER - TY - JOUR A1 - Brumberg, Joachim A1 - Schröter, Nils A1 - Blazhenets, Ganna A1 - Frings, Lars A1 - Volkmann, Jens A1 - Lapa, Constantin A1 - Jost, Wolfgang H. A1 - Isaias, Ioannis U. A1 - Meyer, Philipp T. T1 - Differential diagnosis of parkinsonism: a head-to-head comparison of FDG PET and MIBG scintigraphy JF - NPJ Parkinsons Disease N2 - [\(^{18}\)F]fluorodeoxyglucose (FDG) PET and [\(^{123}\)I]metaiodobenzylguanidine (MIBG) scintigraphy may contribute to the differential diagnosis of neurodegenerative parkinsonism. To identify the superior method, we retrospectively evaluated 54 patients with suspected neurodegenerative parkinsonism, who were referred for FDG PET and MIBG scintigraphy. Two investigators visually assessed FDG PET scans using an ordinal 6-step score for disease-specific patterns of Lewy body diseases (LBD) or atypical parkinsonism (APS) and assigned the latter to the subgroups multiple system atrophy (MSA), progressive supranuclear palsy (PSP), or corticobasal syndrome. Regions-of-interest analysis on anterior planar MIBG images served to calculate the heart-to-mediastinum ratio. Movement disorder specialists blinded to imaging results established clinical follow-up diagnosis by means of guideline-derived case vignettes. Clinical follow-up (1.7 +/- 2.3 years) revealed the following diagnoses: n = 19 LBD (n = 17 Parkinson's disease [PD], n = 1 PD dementia, and n = 1 dementia with Lewy bodies), n = 31 APS (n = 28 MSA, n = 3 PSP), n = 3 non-neurodegenerative parkinsonism; n = 1 patient could not be diagnosed and was excluded. Receiver operating characteristic analyses for discriminating LBD vs. non-LBD revealed a larger area under the curve for FDG PET than for MIBG scintigraphy at statistical trend level for consensus rating (0.82 vs. 0.69, p = 0.06; significant for investigator #1: 0.83 vs. 0.69, p = 0.04). The analysis of PD vs. MSA showed a similar difference (0.82 vs. 0.69, p = 0.11; rater #1: 0.83 vs. 0.69, p = 0.07). Albeit the notable differences in diagnostic performance did not attain statistical significance, the authors consider this finding clinically relevant and suggest that FDG PET, which also allows for subgrouping of APS, should be preferred. KW - clinical diagnosis KW - F-18-FDG PET KW - disease KW - dementia KW - accuracy KW - stimulation KW - guidelines KW - criteria KW - brain KW - risk Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230675 VL - 6 ER - TY - JOUR A1 - Brumberg, Joachim A1 - Kuzkina, Anastasia A1 - Lapa, Constantin A1 - Mammadova, Sona A1 - Buck, Andreas A1 - Volkmann, Jens A1 - Sommer, Claudia A1 - Isaias, Ioannis U. A1 - Doppler, Kathrin T1 - Dermal and cardiac autonomic fiber involvement in Parkinson's disease and multiple system atrophy JF - Neurobiology of Disease N2 - Pathological aggregates of alpha-synuclein in peripheral dermal nerve fibers can be detected in patients with idiopathic Parkinson's disease and multiple system atrophy. This study combines skin biopsy staining for p-alpha-synuclein depositions and radionuclide imaging of the heart with [\(^{123}\)I]-metaiodobenzylguanidine to explore peripheral denervation in both diseases. To this purpose, 42 patients with a clinical diagnosis of Parkinson's disease or multiple system atrophy were enrolled. All patients underwent a standardized clinical workup including neurological evaluation, neurography, and blood samples. Skin biopsies were obtained from the distal and proximal leg, back, and neck for immunofluorescence double labeling with anti-p-alpha-synuclein and anti-PGP9.5. All patients underwent myocardial [\(^{123}\)I]-metaiodobenzylguanidine scintigraphy. Dermal p-alpha-synuclein was observed in 47.6% of Parkinson's disease patients and was mainly found in autonomic structures. 81.0% of multiple system atrophy patients had deposits with most of cases in somatosensory fibers. The [\(^{123}\)I]-metaiodobenzylguanidine heart-to-mediastinum ratio was lower in Parkinson's disease than in multiple system atrophy patients (1.94 +/- 0.63 vs. 2.91 +/- 0.96; p < 0.0001). Irrespective of the diagnosis, uptake was lower in patients with than without p-alpha-synuclein in autonomic structures (1.42 +/- 0.51 vs. 2.74 +/- 0.83; p < 0.0001). Rare cases of Parkinson's disease with p-alpha-synuclein in somatosensory fibers and multiple system atrophy patients with deposits in autonomic structures or both fiber types presented with clinically overlapping features. In conclusion, this study suggests that alpha-synuclein contributes to peripheral neurodegeneration and mediates the impairment of cardiac sympathetic neurons in patients with synucleinopathies. Furthermore, it indicates that Parkinson's disease and multiple system atrophy share pathophysiologic mechanisms of peripheral nervous system dysfunction with a clinical overlap. KW - peripheral nervous system KW - Parkinson's disease KW - skin biopsy KW - MIBG scintigraphy KW - multiple system atrophy Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260061 VL - 153 ER - TY - JOUR A1 - Brumberg, Joachim A1 - Blazhenets, Ganna A1 - Schröter, Nils A1 - Frings, Lars A1 - Jost, Wolfgang H. A1 - Lapa, Constantin A1 - Meyer, Philipp T. T1 - Imaging cardiac sympathetic innervation with MIBG: linear conversion of the heart-to-mediastinum ratio between different collimators JF - EJNMMI Physics N2 - Background The heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible. Methods We included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure. Results H/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R\(^2\) = 0.99, p < 0.001 and R\(^2\) = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 × H/M-ME + 0.63, R\(^2\) = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 ± 0.04; mean relative absolute error 3.2 ± 2.6%). Conclusions The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions. KW - MIBG KW - collimator KW - heart-to-mediastinum ratio KW - linear conversion Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-221675 VL - 6 ER - TY - JOUR A1 - Brumberg, Joachim A1 - Beckl, Melanie A1 - Dierks, Alexander A1 - Schirbel, Andreas A1 - Krebs, Markus A1 - Buck, Andreas A1 - Kübler, Hubert A1 - Lapa, Constantin A1 - Seitz, Anna Katharina T1 - Detection Rate of \(^{68}\)Ga-PSMA Ligand PET/CT in Patients with Recurrent Prostate Cancer and Androgen Deprivation Therapy JF - Biomedicines N2 - Prostate-specific membrane antigen (PSMA) ligand PET/CT enables the localization of tumor lesions in patients with recurrent prostate cancer, but it is unclear whether androgen deprivation therapy (ADT) influences diagnostic accuracy. The aim of this study was to evaluate the effect of ADT on the detection rate of \(^{68}\)Ga-PSMA ligand PET/CT. Thus, 399 patients with initial radical prostatectomy and 68Ga-PSMA ligand PET/CT during PSA relapse were retrospectively evaluated. Propensity score matching was used to create two balanced groups of 62 subjects who either did or did not receive ADT within six months before imaging. All \(^{68}\)Ga-PSMA ligand PET/CT were evaluated visually and with semiquantitative measures. The detection rate of tumor recurrence was significantly higher in the group with ADT (88.7% vs. 72.6%, p = 0.02) and improved with increasing PSA-levels in both groups. In subjects with pathological PET/CT and ADT, whole-body total lesion PSMA (p < 0.01) and PSMA-derived tumor volume (p < 0.01) were significantly higher than in those without ADT. More PSMA-positive lesions and higher PSMA-derived volumetric parameters in patients with ADT suggest that a better detection rate is related to a (biologically) more advanced disease stage. Due to high detection rates in patients with PSA-levels < 2 ng/mL, the withdrawal of ADT before PSMA ligand PET/CT cannot be recommended. KW - 68Ga-PSMA ligand PET/CT KW - androgen deprivation therapy KW - detection rate KW - recurrent prostate cancer Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-219301 SN - 2227-9059 VL - 8 IS - 11 ER - TY - JOUR A1 - Breun, Maria A1 - Monoranu, Camelia M. A1 - Kessler, Almuth F. A1 - Matthies, Cordula A1 - Löhr, Mario A1 - Hagemann, Carsten A1 - Schirbel, Andreas A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Buck, Andreas K. A1 - Wester, Hans-Jürgen A1 - Ernestus, Ralf-Ingo A1 - Lapa, Constantin T1 - [\(^{68}\)Ga]-Pentixafor PET/CT for CXCR4-mediated imaging of vestibular schwannomas JF - Frontiers in Oncology N2 - We have recently demonstrated CXCR4 overexpression in vestibular schwannomas (VS). This study investigated the feasibility of CXCR4-directed positron emission tomography/computed tomography (PET/CT) imaging of VS using the radiolabeled chemokine ligand [\(^{68}\)Ga]Pentixafor. Methods: 4 patients with 6 primarily diagnosed or pre-treated/observed VS were enrolled. All subjects underwent [\(^{68}\)Ga]Pentixafor PET/CT prior to surgical resection. Images were analyzed visually and semi-quantitatively for CXCR4 expression including calculation of tumor-to-background ratios (TBR). Immunohistochemistry served as standard of reference in three patients. Results: [\(^{68}\)Ga]Pentixafor PET/CT was visually positive in all cases. SUV\(_{mean}\) and SUV\(_{max}\) were 3.0 ± 0.3 and 3.8 ± 0.4 and TBR\(_{mean}\) and TBR\(_{max}\) were 4.0 ± 1.4 and 5.0 ± 1.7, respectively. Histological analysis confirmed CXCR4 expression in tumors. Conclusion: Non-invasive imaging of CXCR4 expression using [\(^{68}\)Ga]Pentixafor PET/CT of VS is feasible and could prove useful for in vivo assessment of CXCR4 expression. KW - vestibular schwannoma KW - CXCR4 KW - PET/CT KW - molecular imaging KW - Pentixafor Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-201863 VL - 9 IS - 503 ER -