TY - JOUR A1 - Liu, Dan A1 - Hu, Kai A1 - Störk, Stefan A1 - Herrmann, Sebastian A1 - Kramer, Bastian A1 - Cikes, Maja A1 - Gaudron, Philipp Daniel A1 - Knop, Stefan A1 - Ertl, Georg A1 - Bijnens, Bart A1 - Weidemann, Frank T1 - Predictive Value of Assessing Diastolic Strain Rate on Survival in Cardiac Amyloidosis Patients with Preserved Ejection Fraction JF - PLOS ONE N2 - Objectives: Since diastolic abnormalities are typical findings of cardiac amyloidosis (CA), we hypothesized that speckle-tracking-imaging (STI) derived longitudinal early diastolic strain rate (LSRdias) could predict outcome in CA patients with preserved left ventricular ejection fraction (LVEF >50%). Background: Diastolic abnormalities including altered early filling are typical findings and are related to outcome in CA patients. Reduced longitudinal systolic strain (LSsys) assessed by STI predicts increased mortality in CA patients. It remains unknown if LSRdias also related to outcome in these patients. Methods: Conventional echocardiography and STI were performed in 41 CA patients with preserved LVEF (25 male; mean age 65±9 years). Global and segmental LSsys and LSRdias were obtained in six LV segments from apical 4-chamber views. Results: Nineteen (46%) out of 41 CA patients died during a median of 16 months (quartiles 5–35 months) follow-up. Baseline mitral annular plane systolic excursion (MAPSE, 6±2 vs. 8±3 mm), global LSRdias and basal-septal LSRdias were significantly lower in non-survivors than in survivors (all p<0.05). NYHA class, number of non-cardiac organs involved, MAPSE, mid-septal LSsys, global LSRdias, basal-septal LSRdias and E/LSRdias were the univariable predictors of all-cause death. Multivariable analysis showed that number of non-cardiac organs involved (hazard ratio [HR] = 1.96, 95% confidence interval [CI] 1.17–3.26, P = 0.010), global LSRdias (HR = 7.30, 95% CI 2.08–25.65, P = 0.002), and E/LSRdias (HR = 2.98, 95% CI 1.54–5.79, P = 0.001) remained independently predictive of increased mortality risk. The prognostic performance of global LSRdias was optimal at a cutoff value of 0.85 S−1 (sensitivity 68%, specificity 67%). Global LSRdias <0.85 S−1 predicted a 4-fold increased mortality in CA patients with preserved LVEF. Conclusions: STI-derived early diastolic strain rate is a powerful independent predictor of survival in CA patients with preserved LVEF. KW - diagnostic medicine KW - echocardiography KW - prognosis KW - calcium imaging KW - ejection fraction KW - death rates KW - amyloidosis KW - deformation Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-118024 SN - 1932-6203 VL - 9 IS - 12 ER - TY - JOUR A1 - Liu, Dan A1 - Hu, Kai A1 - Niemann, Markus A1 - Herrmann, Sebastian A1 - Cikes, Maja A1 - Störk, Stefan A1 - Beer, Meinrad A1 - Gaudron, Philipp Daniel A1 - Morbach, Caroline A1 - Knop, Stefan A1 - Geissinger, Eva A1 - Ertl, Georg A1 - Bijnens, Bart A1 - Weidemann, Frank T1 - Impact of Regional Left Ventricular Function on Outcome for Patients with AL Amyloidosis JF - PLoS ONE N2 - Objectives The aim of this study was to explore the left ventricular (LV) deformation changes and the potential impact of deformation on outcome in patients with proven light-chain (AL) amyloidosis and LV hypertrophy. Background Cardiac involvement in AL amyloidosis patients is associated with poor outcome. Detecting regional cardiac function by advanced non-invasive techniques might be favorable for predicting outcome. Methods LV longitudinal, circumferential and radial peak systolic strains (Ssys) were assessed by speckle tracking imaging (STI) in 44 biopsy-proven systemic AL amyloidosis patients with LV hypertrophy (CA) and in 30 normal controls. Patients were divided into compensated (n = 18) and decompensated (n = 26) group based on clinical assessment and followed-up for a median period of 345 days. Results Ejection fraction (EF) was preserved while longitudinal Ssys (LSsys) was significantly reduced in both compensated and decompensated groups. Survival was significantly reduced in decompensated group (35% vs. compensated 78%, P = 0.001). LSsys were similar in apical segments and significantly reduced in basal segments between two patient groups. LSsys at mid-segments were significantly reduced in all LV walls of decompensated group. Patients were further divided into 4 subgroups according to the presence or absence of reduced LSsys in no (normal), only basal (mild), basal and mid (intermediate) and all segments of the septum (severe). This staging revealed continuously worse prognosis in proportion to increasing number of segments with reduced LSsys (mortality: normal 14%, mild 27%, intermediate 67%, and severe 64%). Mid-septum LSsys<11% suggested a 4.8-fold mortality risk than mid-septum LSsys≥11%. Multivariate regression analysis showed NYHA class and mid-septum LSsys were independent predictors for survival. Conclusions Reduced deformation at mid-septum is associated with worse prognosis in systemic amyloidosis patients with LV hypertrophy. KW - regression analysis KW - ejection fraction KW - echocardiography KW - cardiac transplantation KW - deformation KW - amyloidosis KW - prognosis KW - stem cell transplantation Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-130293 VL - 8 IS - 3 ER - TY - JOUR A1 - Kraft, Peter A1 - Fleischer, Anna A1 - Wiedmann, Silke A1 - Rücker, Viktoria A1 - Mackenrodt, Daniel A1 - Morbach, Caroline A1 - Malzahn, Uwe A1 - Kleinschnitz, Christoph A1 - Störk, Stefan A1 - Heuschmann, Peter U. T1 - Feasibility and diagnostic accuracy of point-of-care handheld echocardiography in acute ischemic stroke patients - a pilot study JF - BMC Neurology N2 - Background: Standard echocardiography (SE) is an essential part of the routine diagnostic work-up after ischemic stroke (IS) and also serves for research purposes. However, access to SE is often limited. We aimed to assess feasibility and accuracy of point-of-care (POC) echocardiography in a stroke unit (SU) setting. Methods: IS patients were recruited on the SU of the University Hospital Würzburg, Germany. Two SU team members were trained in POC echocardiography for a three-month period to assess a set of predefined cardiac parameters including left ventricular ejection fraction (LVEF). Diagnostic agreement was assessed by comparing POC with SE executed by an expert sonographer, and intraclass correlation coefficient (ICC) or kappa (κ) with 95% confidence intervals (95% CI) were calculated. Results: In the 78 patients receiving both POC and SE agreement for cardiac parameters was good, with ICC varying from 0.82 (95% CI 0.71–0.89) to 0.93 (95% CI 0.87–0.96), and κ from 0.39 (−95% CI 0.14–0.92) to 0.79 (95% CI 0.67–0.91). Detection of systolic dysfunction with POC echocardiography compared to SE was very good, with an area under the curve of 0.99 (0.96–1.00). Interrater agreement for LVEF measured by POC echocardiography was good with κ 0.63 (95% CI 0.40–0.85). Conclusions: POC echocardiography in a SU setting is feasible enabling reliable quantification of LVEF and preliminary assessment of selected cardiac parameters that might be used for research purposes. Its potential clinical utility in triaging stroke patients who should undergo or do not necessarily require SE needs to be investigated in larger prospective diagnostic studies. KW - ischemic stroke KW - systolic dysfunction KW - point-of-care echocardiography KW - ejection fraction KW - stroke unit KW - feasibility KW - accuracy Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158081 VL - 17 IS - 159 ER - TY - JOUR A1 - Eissler, Cristoph A1 - Werner, Rudolf A. A1 - Arias-Loza, Paula A1 - Nose, Naoko A1 - Chen, Xinyu A1 - Pomper, Martin G. A1 - Rowe, Steven P. A1 - Lapa, Constantin A1 - Buck, Andreas K. A1 - Higuchi, Takahiro T1 - The number of frames on ECG-gated \(^{18}\)F-FDG small animal PET has a significant impact on LV systolic and diastolic functional parameters JF - Molecular Imaging N2 - Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. \(^{18}\)F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 & PLUSMN; 57.7 mu l*, 380.8 & PLUSMN; 57.2 mu l*, 398.0 & PLUSMN; 63.1 mu l*, and 444.8 & PLUSMN; 75.3 mu l at 4, 8, 12, and 16 frames, respectively; *P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed (P < 0.005), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used. KW - Myocardial-perfusion SPECT KW - left-ventricular function KW - ejection fraction KW - MRI Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-265778 VL - 2021 ER -