TY - JOUR A1 - Lohr, David A1 - Terekhov, Maxim A1 - Weng, Andreas Max A1 - Schroeder, Anja A1 - Walles, Heike A1 - Schreiber, Laura Maria T1 - Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T JF - PLoS ONE N2 - Purpose of this work was to assess feasibility of cardiac diffusion tensor imaging (cDTI) at 7 T in a set of healthy, unfixed, porcine hearts using various parallel imaging acceleration factors and to compare SNR and derived cDTI metrics to a reference measured at 3 T. Magnetic resonance imaging was performed on 7T and 3T whole body systems using a spin echo diffusion encoding sequence with echo planar imaging readout. Five reference (b = 0 s/mm\(^2\)) images and 30 diffusion directions (b = 700 s/mm\(^2\)) were acquired at both 7 T and 3 T using a GRAPPA acceleration factor R = 1. Scans at 7 T were repeated using R = 2, R = 3, and R = 4. SNR evaluation was based on 30 reference (b = 0 s/mm\(^2\)) images of 30 slices of the left ventricle and cardiac DTI metrics were compared within AHA segmentation. The number of hearts scanned at 7 T and 3 T was n = 11. No statistically significant differences were found for evaluated helix angle, secondary eigenvector angle, fractional anisotropy and apparent diffusion coefficient at the different field strengths, given sufficiently high SNR and geometrically undistorted images. R≥3 was needed to reduce susceptibility induced geometric distortions to an acceptable amount. On average SNR in myocardium of the left ventricle was increased from 29±3 to 44±6 in the reference image (b = 0 s/mm\(^2\)) when switching from 3 T to 7 T. Our study demonstrates that high resolution, ex vivo cDTI is feasible at 7 T using commercial hardware. KW - Heart KW - Diffusion tensor imaging KW - Eigenvectors KW - Cardiac ventricles KW - Tractography KW - Magnetic resonance imaging KW - Data acquisition KW - Swine Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-201376 VL - 14 IS - 3 ER - TY - THES A1 - Slawig, Anne T1 - Reconstruction methods for the frequency-modulated balanced steady-state free precession MRI-sequence T1 - Rekonstruktionsmethoden für die frequenz-modulierte balanced steady-state free precession MRT-Sequenz N2 - This work considered the frequency-modulated balanced steady-state free precession (fm-bSSFP) sequence as a tool to provide banding free bSSFP MR images. The sequence was implemented and successfully applied to suppress bandings in various in vitro and in vivo examples. In combination with a radial trajectory it is a promising alternative for standard bSSFP applications. First, two specialized applications were shown to establish the benefits of the acquisition strategy in itself. In real time cardiac imaging, it was shown that the continuous shift in frequency causes a movement of the bandings across the FOV. Thus, no anatomical region is constantly impaired, and a suitable timeframe can be found to examine all important structures. Furthermore, a combination of images with different artifact positions, similar to phase-cycled acquisitions is possible. In this way, fast, banding-free imaging of the moving heart was realized. Second, acquisitions with long TR were shown. While standard bSSFP suffers from increasing incidence of bandings with higher TR values, the frequency-modulated approach provided banding free images, regardless of the TR. A huge disadvantage of fm-bSSFP, in combination with the radial trajectory, is the decrease in signal intensity. In this work a specialized reconstruction method, the multifrequency reconstruction for frequency-modulated bSSFP (Muffm), was established, which successfully compensated that phenomena. The application of Muffm to several anatomical sites, such as inner ear, legs and cardiac acquisitions, proofed the advantageous SNR of the reconstruction. Furthermore, fm-bSSFP was applied to the clinically highly relevant task of water-fat separation. Former approaches of a phase-sensitive separation procedure in combination with standard bSSFP showed promising results but failed in cases of high inhomogeneity or high field strengths where banding artifacts become a major issue. The novel approach of using the fm-bSSFP acquisition strategy with the separation approach provided robust, reliable images of high quality. Again, losses in signal intensity could be regained by Muffm, as both approaches are completely compatible. Opposed to conventional banding suppression techniques, like frequency-scouts or phase-cycling, all reconstruction methods established in this work rely on a single radial acquisition, with scan times similar to standard bSSFP scans. No prolonged measurement times occur and patient time in the scanner is kept as short as possible, improving patient comfort, susceptibility to motion or physiological noise and cost of one scan. All in all, the frequency-modulated acquisition in combination with specializes reconstruction methods, leads to a completely new quality of images with short acquisition times. N2 - In dieser Arbeit wird eine Modifikation der balanced steady-state free precession (bSSFP) Sequenz betrachtet. Die frequenzmodulierte bSSFP-Sequenz (fm-bSSFP) kann die sonst typischen Band-Artefakte in bSSFP-MR-Bildern verhindern. Die Sequenz wurde im Rahmen der Arbeit am MR-Scanner implementiert und erfolgreich in verschiedenen in-vitro- und in-vivo-Beispielen angewendet. In Kombination mit einer radialen Trajektorie erwies es sich als eine vielversprechende Alternative für alle Standard-bSSFP Anwendungen. Zuerst wurden zwei spezialisierte Anwendungen gezeigt, um die Vorteile der Akquisitionsstrategie an sich darzustellen. Am Beispiel der Echtzeit-Herzbildgebung konnte mit Hilfe der kontinuierlichen Frequenzverschiebung eine Bewegung der Bänder über das FOV erzeugt werden. Somit wird keine anatomische Region ständig von Artefakten überlagert und für jeden Bereich kann ein geeigneter Zeitrahmen gefunden werden, um die wichtigen Strukturen darzustellen und zu untersuchen. Darüber hinaus ist eine Kombination von Bildern mit verschiedenen Artefaktpositionen möglich, ähnlich zu mehreren Aufnahmen mit verschiedenen Phasenzyklen. Auf diese Weise wurde eine schnelle Bildgebung des sich bewegenden Herzens ohne Bandartefakte realisiert. Zusätzlich wurden Aufnahmen mit langen Repetitionszeiten (TR) untersucht. Während in der Standard-bSSFP die Häufigkeit von Bandartefakten mit steigendem TR-Wert zunimmt, lieferte der frequenzmodulierte Ansatz Banding-freie Bilder unabhängig vom TR. Ein großer Nachteil von fm-bSSFP in Kombination mit der radialen Trajektorie ist der Verlust von Signalintensität bei der Rekonstruktion. In dieser Arbeit wurde eine spezielle Rekonstruktionsmethode namens Muffm (mulitfrequency reconstruction for frequency-modulated bSSFP) etabliert, die diesen Verlust erfolgreich kompensieren kann. Die Anwendung von Muffm an verschiedenen anatomischen Strukturen, wie Innenohr, Bein und Herzaufnahmen, bestätigte das vorteilhafte Signal-zu-Rausch-Verhältnis, dass durch die spezielle Rekonstruktion gewonnen werden kann. Darüber hinaus wurde die fm-bSSFP auf die klinisch interessante Wasser-Fett-Trennung angewandt. Frühere Ansätze eines phasenempfindlichen Trennverfahrens in Kombination mit Standard-bSSFP zeigten vielversprechende Ergebnisse, scheiterten jedoch in Fällen hoher Inhomogenität oder hoher Feldstärken an den auftretenden Bandartefakten. Der neue Ansatz, diesen Separationsalgorithmus mit der fm-bSSFP-Akquisitionsstrategie zu verbinden, lieferte robuste, zuverlässige Bilder von hoher Qualität. Auch hier konnten entstehende Verluste in der Signalintensität durch Muffm zurückgewonnen werden, da beide Ansätze vollständig kompatibel sind. Im Gegensatz zu herkömmlichen Bandunterdrückungstechniken, wie Frequenz-Scouts oder die Aufnahme mehrerer Bilder mit verschiedenen Phasenzyklen, beruhen alle in dieser Arbeit etablierten Rekonstruktionsverfahren auf einer einzigen radialen Aufnahme. Die Messzeiten sind daher identisch zur Aufnahme einer Standard-bSSFP Messung. Das Verfahren ermöglicht eine deutliche Verkürzung der Aufenthaltsdauer im Scanner bei einer gleichzeitigen Garantie ein artefaktfreies Bild zu erhalten. Damit ist es insbesondere für Patienten von Vorteil, die unter Platzangst oder sonstigen Beschwerden leiden, die ein langes Stillliegen erschweren. Außerdem werden Bewegungsartefakte, physiologisches Rauschen und nicht zuletzt die Kosten eines Scans minimiert. Insgesamt bietet die frequenzmodulierte bSSFP Aufnahme in Kombination mit spezialisierten Rekonstruktionsverfahren neue Möglichkeiten zur schnellen Aufnahme von Bildern ohne Bandartefakte. KW - Kernspintomografie KW - Magnetic resonance imaging KW - MRI KW - MRT KW - bSSFP KW - Rekonstruktion KW - reconstruction KW - frequency modulation KW - water fat separation KW - Wasser Fett Trennung KW - balanced steady state free precession Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-162871 ER - TY - JOUR A1 - Triphan, Simon M. F. A1 - Jobst, Bertram J. A1 - Anjorin, Angela A1 - Sedlaczek, Oliver A1 - Wolf, Ursula A1 - Terekhov, Maxim A1 - Hoffmann, Christian A1 - Ley, Sebastian A1 - Düber, Christoph A1 - Biederer, Jürgen A1 - Kauczor, Hans-Ulrich A1 - Jakob, Peter M. A1 - Wielpütz, Mark O. T1 - Reproducibility and comparison of oxygen-enhanced T\(_1\) quantification in COPD and asthma patients JF - PLoS ONE N2 - T\(_1\) maps have been shown to yield useful diagnostic information on lung function in patients with chronic obstructive pulmonary disease (COPD) and asthma, both for native T\(_1\) and ΔT\(_1\), the relative reduction while breathing pure oxygen. As parameter quantification is particularly interesting for longitudinal studies, the purpose of this work was both to examine the reproducibility of lung T\(_1\) mapping and to compare T\(_1\) found in COPD and asthma patients using IRSnapShotFLASH embedded in a full MRI protocol. 12 asthma and 12 COPD patients (site 1) and further 15 COPD patients (site 2) were examined on two consecutive days. In each patient, T\(_1\) maps were acquired in 8 single breath-hold slices, breathing first room air, then pure oxygen. Maps were partitioned into 12 regions each to calculate average values. In asthma patients, the average T\(_{1,RA}\) = 1206ms (room air) was reduced to T\(_{1,O2}\) = 1141ms under oxygen conditions (ΔT\(_1\) = 5.3%, p < 5⋅10\(^{−4})\), while in COPD patients both native T\(_{1,RA}\) = 1125ms was significantly shorter (p < 10\(^{−3})\) and the relative reduction to T\(_{1,O2}\) = 1081ms on average ΔT\(_1\) = 4.2%(p < 10\(^{−5}\)). On the second day, with T\(_{1,RA}\) = 1186ms in asthma and T\(_{1,RA}\) = 1097ms in COPD, observed values were slightly shorter on average in all patient groups. ΔT\(_1\) reduction was the least repeatable parameter and varied from day to day by up to 23% in individual asthma and 30% in COPD patients. While for both patient groups T\(_1\) was below the values reported for healthy subjects, the T\(_1\) and ΔT\(_1\) found in asthmatics lies between that of the COPD group and reported values for healthy subjects, suggesting a higher blood volume fraction and better ventilation. However, it could be demonstrated that lung T\(_1\) quantification is subject to notable inter-examination variability, which here can be attributed both to remaining contrast agent from the previous day and the increased dependency of lung T\(_1\) on perfusion and thus current lung state. KW - Medicine KW - Chronic obstrusive pulmonary disease KW - Asthma KW - Oxygen KW - Magnetic resonance imaging KW - Breathing KW - Pulmonary imaging KW - Protons KW - Diagnostic medicine Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-171833 VL - 12 IS - 2 ER - TY - JOUR A1 - Gotschy, Alexander A1 - Bauer, Wolfgang R. A1 - Winter, Patrick A1 - Nordbeck, Peter A1 - Rommel, Eberhard A1 - Jakob, Peter M. A1 - Herold, Volker T1 - Local versus global aortic pulse wave velocity in early atherosclerosis: An animal study in ApoE\(^{-/-}\) mice using ultrahigh field MRI JF - PLoS ONE N2 - Increased aortic stiffness is known to be associated with atherosclerosis and has a predictive value for cardiovascular events. This study aims to investigate the local distribution of early arterial stiffening due to initial atherosclerotic lesions. Therefore, global and local pulse wave velocity (PWV) were measured in ApoE\(^{-/-}\) and wild type (WT) mice using ultrahigh field MRI. For quantification of global aortic stiffness, a new multi-point transit-time (TT) method was implemented and validated to determine the global PWV in the murine aorta. Local aortic stiffness was measured by assessing the local PWV in the upper abdominal aorta, using the flow/area (QA) method. Significant differences between age matched ApoE\(^{-/-}\) and WT mice were determined for global and local PWV measurements (global PWV: ApoE\(^{-/-}\): 2.7 ±0.2m/s vs WT: 2.1±0.2m/s, P<0.03; local PWV: ApoE\(^{-/-}\): 2.9±0.2m/s vs WT: 2.2±0.2m/s, P<0.03). Within the WT mouse group, the global PWV correlated well with the local PWV in the upper abdominal aorta (R\(^2\) = 0.75, P<0.01), implying a widely uniform arterial elasticity. In ApoE\(^{-/-}\) animals, however, no significant correlation between individual local and global PWV was present (R\(^2\) = 0.07, P = 0.53), implying a heterogeneous distribution of vascular stiffening in early atherosclerosis. The assessment of global PWV using the new multi-point TT measurement technique was validated against a pressure wire measurement in a vessel phantom and showed excellent agreement. The experimental results demonstrate that vascular stiffening caused by early atherosclerosis is unequally distributed over the length of large vessels. This finding implies that assessing heterogeneity of arterial stiffness by multiple local measurements of PWV might be more sensitive than global PWV to identify early atherosclerotic lesions. KW - MRI KW - Atherosclerosis KW - Aorta KW - Stiffness KW - Measurement KW - Time measurement KW - Magnetic resonance imaging KW - Mouse models KW - Systole Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-171824 VL - 12 IS - 2 ER - TY - JOUR A1 - Kaireit, Till F. A1 - Sorrentino, Sajoscha A. A1 - Renne, Julius A1 - Schoenfeld, Christian A1 - Voskrebenzev, Andreas A1 - Gutberlet, Marcel A1 - Schulz, Angela A1 - Jakob, Peter M. A1 - Hansen, Gesine A1 - Wacker, Frank A1 - Welte, Tobias A1 - Tümmler, Burkhard A1 - Vogel-Claussen, Jens T1 - Functional lung MRI for regional monitoring of patients with cystic fibrosis JF - PLoS ONE N2 - Purpose To test quantitative functional lung MRI techniques in young adults with cystic fibrosis (CF) compared to healthy volunteers and to monitor immediate treatment effects of a single inhalation of hypertonic saline in comparison to clinical routine pulmonary function tests. Materials and methods Sixteen clinically stable CF patients and 12 healthy volunteers prospectively underwent two functional lung MRI scans and pulmonary function tests before and 2h after a single treatment of inhaled hypertonic saline or without any treatment. MRI-derived oxygen enhanced T1 relaxation measurements, fractional ventilation, first-pass perfusion parameters and a morpho-functional CF-MRI score were acquired. Results Compared to healthy controls functional lung MRI detected and quantified significantly increased ventilation heterogeneity in CF patients. Regional functional lung MRI measures of ventilation and perfusion as well as the CF-MRI score and pulmonary function tests could not detect a significant treatment effect two hours after a single treatment with hypertonic saline in young adults with CF (p>0.05). Conclusion This study shows the feasibility of functional lung MRI as a non-invasive, radiation-free tool for monitoring patients with CF. KW - Physics KW - Magnetic resonance imaging KW - Functional magnetic resonance imaging KW - Cystic fibrosis KW - Oxygen KW - Pulmonary imaging KW - Hypertonic KW - Pulmonary function KW - Quantum chronodynamics Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-172457 VL - 12 IS - 12 ER - TY - JOUR A1 - Jarius, Sven A1 - Ruprecht, Klemens A1 - Kleiter, Ingo A1 - Borisow, Nadja A1 - Asgari, Nasrin A1 - Pitarokoili, Kalliopi A1 - Pache, Florence A1 - Stich, Oliver A1 - Beume, Lena-Alexandra A1 - Hümmert, Martin W. A1 - Ringelstein, Marius A1 - Trebst, Corinna A1 - Winkelmann, Alexander A1 - Schwarz, Alexander A1 - Buttmann, Mathias A1 - Zimmermann, Hanna A1 - Kuchling, Joseph A1 - Franciotta, Diego A1 - Capobianco, Marco A1 - Siebert, Eberhard A1 - Lukas, Carsten A1 - Korporal-Kuhnke, Mirjam A1 - Haas, Jürgen A1 - Fechner, Kai A1 - Brandt, Alexander U. A1 - Schanda, Kathrin A1 - Aktas, Orhan A1 - Paul, Friedemann A1 - Reindl, Markus A1 - Wildemann, Brigitte T1 - MOG-IgG in NMO and related disorders: a multicenter study of 50 patients. Part 2: Epidemiology, clinical presentation, radiological and laboratory features, treatment responses, and long-term outcome JF - Journal of Neuroinflammation N2 - Background A subset of patients with neuromyelitis optica spectrum disorders (NMOSD) has been shown to be seropositive for myelin oligodendrocyte glycoprotein antibodies (MOG-IgG). Objective To describe the epidemiological, clinical, radiological, cerebrospinal fluid (CSF), and electrophysiological features of a large cohort of MOG-IgG-positive patients with optic neuritis (ON) and/or myelitis (n = 50) as well as attack and long-term treatment outcomes. Methods Retrospective multicenter study. Results The sex ratio was 1:2.8 (m:f). Median age at onset was 31 years (range 6-70). The disease followed a multiphasic course in 80% (median time-to-first-relapse 5 months; annualized relapse rate 0.92) and resulted in significant disability in 40% (mean follow-up 75 ± 46.5 months), with severe visual impairment or functional blindness (36%) and markedly impaired ambulation due to paresis or ataxia (25%) as the most common long-term sequelae. Functional blindness in one or both eyes was noted during at least one ON attack in around 70%. Perioptic enhancement was present in several patients. Besides acute tetra-/paraparesis, dysesthesia and pain were common in acute myelitis (70%). Longitudinally extensive spinal cord lesions were frequent, but short lesions occurred at least once in 44%. Fourty-one percent had a history of simultaneous ON and myelitis. Clinical or radiological involvement of the brain, brainstem, or cerebellum was present in 50%; extra-opticospinal symptoms included intractable nausea and vomiting and respiratory insufficiency (fatal in one). CSF pleocytosis (partly neutrophilic) was present in 70%, oligoclonal bands in only 13%, and blood-CSF-barrier dysfunction in 32%. Intravenous methylprednisolone (IVMP) and long-term immunosuppression were often effective; however, treatment failure leading to rapid accumulation of disability was noted in many patients as well as flare-ups after steroid withdrawal. Full recovery was achieved by plasma exchange in some cases, including after IVMP failure. Breakthrough attacks under azathioprine were linked to the drug-specific latency period and a lack of cotreatment with oral steroids. Methotrexate was effective in 5/6 patients. Interferon-beta was associated with ongoing or increasing disease activity. Rituximab and ofatumumab were effective in some patients. However, treatment with rituximab was followed by early relapses in several cases; end-of-dose relapses occurred 9-12 months after the first infusion. Coexisting autoimmunity was rare (9%). Wingerchuk’s 2006 and 2015 criteria for NMO(SD) and Barkhof and McDonald criteria for multiple sclerosis (MS) were met by 28%, 32%, 15%, 33%, respectively; MS had been suspected in 36%. Disease onset or relapses were preceded by infection, vaccination, or pregnancy/delivery in several cases. Conclusion Our findings from a predominantly Caucasian cohort strongly argue against the concept of MOG-IgG denoting a mild and usually monophasic variant of NMOSD. The predominantly relapsing and often severe disease course and the short median time to second attack support the use of prophylactic long-term treatments in patients with MOG-IgG-positive ON and/or myelitis. KW - Myelin oligodendrocyte glycoprotein antibodies (MOG-IgG) KW - Aquaporin-4 antibodies (AQP4-IgG, NMO-IgG) KW - Optic neuritis KW - Transverse myelitis KW - Longitudinally extensive transverse myelitis KW - Magnetic resonance imaging KW - Autoantibodies KW - Neuromyelitis optica spectrum disorders (NMOSD) KW - Cerebrospinal fluid KW - Oligoclonal bands KW - Electrophysiology KW - Evoked potentials KW - Treatment KW - Therapy KW - Methotrexate KW - Azathioprine KW - Rituximab KW - Ofatumumab KW - Interferon beta KW - Glatiramer acetate KW - Natalizumab KW - Outcome KW - Pregnancy KW - Infections KW - Vaccination KW - Multiple sclerosis KW - Barkhof criteria KW - McDonald criteria KW - Wingerchuk criteria 2006 and 2015 KW - IPND criteria KW - International consensus diagnostic criteria for neuromyelitis optica spectrum disorders Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-165570 VL - 13 IS - 280 ER -