TY - JOUR A1 - Boelch, S. P. A1 - Jansen, H. A1 - Meffert, R. H. A1 - Frey, S. P. T1 - Six Sesamoid Bones on Both Feet: Report of a Rare Case JF - Journal of Clinical and Diagnostic Research N2 - There is a variation of the total number of distinct bones in the human in the literature. This difference is mainly caused by the variable existence of sesamoid bones. Sesamoid bones at the first MTP are seen regularly. In contrast additional sesamoid bones at the divond to fifth MTP are rare. We report a case of additional sesamoid bones at every metatarsophalangeal joint (MTP) of both feet. A 22-year-old female Caucasian presented with weight-dependent pain of the divond MTP of the left foot. In the radiographs of both feet additional sesamoid bones at every MTP could be seen. This case reports a very rare variation in human anatomy. A similar case has not been displayed to the academic society and therefore should be acknowledged. KW - anatomy KW - genetics KW - variation Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126073 VL - 9 IS - 8 ER - TY - JOUR A1 - Jordan, Martin C. A1 - Jäckle, Veronika A1 - Scheidt, Sebastian A1 - Gilbert, Fabian A1 - Hölscher-Doht, Stefanie A1 - Ergün, Süleyman A1 - Meffert, Rainer H. A1 - Heintel, Timo M. T1 - Trans-obturator cable fixation of open book pelvic injuries JF - Scientific Reports N2 - Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications. KW - anatomy KW - medical research Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-261212 VL - 11 IS - 1 ER -