TY - JOUR A1 - Sterkenburg, Anthe S. A1 - Hoffmann, Anika A1 - Reichel, Julia A1 - Lohle, Kristin A1 - Eveslage, Maria A1 - Warmuth-Metz, Monika A1 - Müller, Hermann L. T1 - Nuchal skinfold thickness: A novel parameter for assessment of body composition in childhood craniopharyngioma JF - Journal of Clinical Endocrinology & Metabolism N2 - Context: Hypothalamic obesity, cardiovascular disease (CVD), and relapse/progression have a major impact on prognosis in childhood-onset craniopharyngioma (CP). We analyzed nuchal skinfold thickness (NST) on magnetic resonance imaging performed for follow-up monitoring as a novel parameter for body composition (BC) and CVD in CP. Objective: The objective of the study was to identify the association of NST with body mass index (BMI), waist to height ratio (WHtR), functional capacity, and blood pressure (BP) in CP and controls. Design: This was a cross-sectional and longitudinal prospective study in CP patients. Setting: The study was conducted at HIT-Endo, KRANIOPHARYNGEOM 2000/2007. Patients: Participants included 94 CP patients and 75 controls. Interventions: There were no interventions. Main Outcome Measures: Association of NST with BC and BP in 43 CP and 43 controls was measured. Results: NST correlated with BMI SD score (SDS; r = 0.78; P = .001; n = 169) and WHtR (r = 0.85; P = .001; n = 86) in the total cohort and CP patients (NST-BMI SDS: r = 0.77, P = .001, n = 94); NST-WHtR: r = 0.835, P = .001, n = 43) and controls (NST-BMI SDS: r = 0.792, P = .001, n = 75; NST-WHtR: r = 0.671, P = .001, n = 43). In CP, systolic BP correlated with NST (r = 0.575, P = .001), BMI SDS (r = 0.434, P = .004), and WHtR (r = 0.386, P = .011). Similar results were observed for diastolic BP in CP. In multivariate analyses, NST had a predictive value for hypertension in postpubertal CP and controls (odds ratio 6.98, 95% confidence interval 1.65, 29.5], P = .008). During a longitudinal follow-up, changes in NST correlated with changes in BMI SDS (P = .001) and WHtR (P = .01) but not with changes in BP and functional capacity. Conclusions: Because monitoring of magnetic resonance imaging and BC is essential for follow-up in CP, NST could serve as a novel and clinically relevant parameter for longitudinal assessment of BC and CVD risk in CP. KW - to-height ratio KW - subcutaneous adipose-tissue KW - disease risk-factors KW - long-term survivors KW - guality-of-life KW - mass index KW - neck circumference KW - onset craniopharyngioma KW - german multicenter KW - visceral adiposity Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-186562 VL - 101 IS - 12 ER - TY - JOUR A1 - Stetter, Christian A1 - Weidner, Franziska A1 - Lilla, Nadine A1 - Weiland, Judith A1 - Kunze, Ekkehard A1 - Ernestus, Ralf-Ingo A1 - Muellenbach, Ralf Michael A1 - Westermaier, Thomas T1 - Therapeutic hypercapnia for prevention of secondary ischemia after severe subarachnoid hemorrhage: physiological responses to continuous hypercapnia JF - Scientific Reports N2 - Temporary hypercapnia has been shown to increase cerebral blood flow (CBF) and might be used as a therapeutical tool in patients with severe subarachnoid hemorrhage (SAH). It was the aim of this study was to investigate the optimum duration of hypercapnia. This point is assumed to be the time at which buffer systems become active, cause an adaptation to changes of the arterial partial pressure of carbon dioxide (PaCO2) and annihilate a possible therapeutic effect. In this prospective interventional study in a neurosurgical ICU the arterial partial pressure of carbon dioxide (PaCO\(_2\)) was increased to a target range of 55 mmHg for 120 min by modification of the respiratory minute volume (RMV) one time a day between day 4 and 14 in 12 mechanically ventilated poor-grade SAH-patients. Arterial blood gases were measured every 15 min. CBF and brain tissue oxygen saturation (StiO\(_2\)) were the primary and secondary end points. Intracranial pressure (ICP) was controlled by an external ventricular drainage. Under continuous hypercapnia (PaCO\(_2\) of 53.17 ± 5.07), CBF was significantly elevated between 15 and 120 min after the start of hypercapnia. During the course of the trial intervention, cardiac output also increased significantly. To assess the direct effect of hypercapnia on brain perfusion, the increase of CBF was corrected by the parallel increase of cardiac output. The maximum direct CBF enhancing effect of hypercapnia of 32% was noted at 45 min after the start of hypercapnia. Thereafter, the CBF enhancing slowly declined. No relevant adverse effects were observed. CBF and StiO\(_2\) reproducibly increased by controlled hypercapnia in all patients. After 45 min, the curve of CBF enhancement showed an inflection point when corrected by cardiac output. It is concluded that 45 min might be the optimum duration for a therapeutic use and may provide an optimal balance between the benefits of hypercapnia and risks of a negative rebound effect after return to normal ventilation parameters. KW - cerebrovascular disorders KW - clinical trials KW - neurology KW - neurovascular disorders KW - Phase II trials Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260779 VL - 11 IS - 1 ER - TY - JOUR A1 - Strinitz, Marc A1 - Pham, Mirko A1 - März, Alexander G. A1 - Feick, Jörn A1 - Weidner, Franziska A1 - Vogt, Marius L. A1 - Essig, Fabian A1 - Neugebauer, Hermann A1 - Stoll, Guido A1 - Schuhmann, Michael K. A1 - Kollikowski, Alexander M. T1 - Immune cells invade the collateral circulation during human stroke: prospective replication and extension JF - International Journal of Molecular Sciences N2 - It remains unclear if principal components of the local cerebral stroke immune response can be reliably and reproducibly observed in patients with acute large-vessel-occlusion (LVO) stroke. We prospectively studied a large independent cohort of n = 318 consecutive LVO stroke patients undergoing mechanical thrombectomy during which cerebral blood samples from within the occluded anterior circulation and systemic control samples from the ipsilateral cervical internal carotid artery were obtained. An extensive protocol was applied to homogenize the patient cohort and to standardize the procedural steps of endovascular sample collection, sample processing, and laboratory analyses. N = 58 patients met all inclusion criteria. (1) Mean total leukocyte counts were significantly higher within the occluded ischemic cerebral vasculature (I) vs. intraindividual systemic controls (S): +9.6%, I: 8114/µL ± 529 vs. S: 7406/µL ± 468, p = 0.0125. (2) This increase was driven by neutrophils: +12.1%, I: 7197/µL ± 510 vs. S: 6420/µL ± 438, p = 0.0022. Leukocyte influx was associated with (3) reduced retrograde collateral flow (R\(^2\) = 0.09696, p = 0.0373) and (4) greater infarct extent (R\(^2\) = 0.08382, p = 0.032). Despite LVO, leukocytes invade the occluded territory via retrograde collateral pathways early during ischemia, likely compromising cerebral hemodynamics and tissue integrity. This inflammatory response can be reliably observed in human stroke by harvesting immune cells from the occluded cerebral vascular compartment. KW - ischemic stroke KW - cerebral ischemia KW - mechanical thrombectomy KW - large vessel occlusion KW - leukocytes KW - neutrophils KW - collateral circulation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-284281 SN - 1422-0067 VL - 22 IS - 17 ER - TY - JOUR A1 - Taeger, Johannes A1 - Müller-Graff, Franz-Tassilo A1 - Lukas, Ilgen A1 - Schendzielorz, Philipp A1 - Hagen, Rudolf A1 - Neun, Tilman A1 - Rak, Kristen T1 - Cochlear duct length measurements in computed tomography and magnetic resonance imaging using newly developed techniques JF - OTO Open N2 - Objective Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). Study Design Retrospective data analyses of 42 cochleae. Setting Tertiary care medical center. Methods Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. Results CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). Conclusion In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established. KW - CDL KW - cochlear implantation KW - temporal bone KW - CT KW - MRI Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-263922 VL - 5 IS - 3 ER - TY - JOUR A1 - Taeger, Johannes A1 - Müller-Graff, Franz-Tassilo A1 - Neun, Tilmann A1 - Köping, Maria A1 - Schendzielorz, Philipp A1 - Hagen, Rudolf A1 - Rak, Kristen T1 - Highly precise navigation at the lateral skull base by the combination of flat-panel volume CT and electromagnetic navigation JF - Science Progress N2 - This study aimed to evaluate the feasibility and accuracy of electromagnetic navigation at the lateral skull base in combination with flat panel volume computed tomography (fpVCT) datasets. A mastoidectomy and a posterior tympanotomy were performed on 10 samples of fresh frozen temporal bones. For registration, four self-drilling titanium screws were applied as fiducial markers. Multi-slice computed tomography (MSCT; 600 µm), conventional flat panel volume computed tomography (fpVCT; 466 µm), micro-fpVCT (197 µm) and secondary reconstructed fpVCT (100 µM) scans were performed and data were loaded into the navigation system. The resulting fiducial registration error (FRE) was analysed, and control of the navigation accuracy was performed. The registration process was very quick and reliable with the screws as fiducials. Compared to using the MSCT data, the micro-fpVCT data led to significantly lower FRE values, whereas conventional fpVCT and secondary reconstructed fpVCT data had no advantage in terms of accuracy. For all imaging modalities, there was no relevant visual deviation when targeting defined anatomical points with a navigation probe. fpVCT data are very well suited for electromagnetic navigation at the lateral skull base. The use of titanium screws as fiducial markers turned out to be ideal for comparing different imaging methods. A further evaluation of this approach by a clinical trial is required. KW - electromagnetic navigation KW - fpVCT KW - fiducial registration error KW - lateral skull base KW - otology KW - cochlear implantation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-250268 SN - 2047-7163 VL - 104 IS - 3 ER - TY - JOUR A1 - Traub, Jan A1 - Otto, Markus A1 - Sell, Roxane A1 - Göpfert, Dennis A1 - Homola, György A1 - Steinacker, Petra A1 - Oeckl, Patrick A1 - Morbach, Caroline A1 - Frantz, Stefan A1 - Pham, Mirko A1 - Störk, Stefan A1 - Stoll, Guido A1 - Frey, Anna T1 - Serum phosphorylated tau protein 181 and neurofilament light chain in cognitively impaired heart failure patients JF - Alzheimer's Research & Therapy N2 - Background Chronic heart failure (HF) is known to increase the risk of developing Alzheimer’s dementia significantly. Thus, detecting and preventing mild cognitive impairment, which is common in patients with HF, is of great importance. Serum biomarkers are increasingly used in neurological disorders for diagnostics, monitoring, and prognostication of disease course. It remains unclear if neuronal biomarkers may help detect cognitive impairment in this high-risk population. Also, the influence of chronic HF and concomitant renal dysfunction on these biomarkers is not well understood. Methods Within the monocentric Cognition.Matters-HF study, we quantified the serum levels of phosphorylated tau protein 181 (pTau) and neurofilament light chain (NfL) of 146 extensively phenotyped chronic heart failure patients (aged 32 to 85 years; 15.1% women) using ultrasensitive bead-based single-molecule immunoassays. The clinical work-up included advanced cognitive testing and cerebral magnetic resonance imaging (MRI). Results Serum concentrations of NfL ranged from 5.4 to 215.0 pg/ml (median 26.4 pg/ml) and of pTau from 0.51 to 9.22 pg/ml (median 1.57 pg/ml). We detected mild cognitive impairment (i.e., T-score < 40 in at least one cognitive domain) in 60% of heart failure patients. pTau (p = 0.014), but not NfL, was elevated in this group. Both NfL (ρ = − 0.21; p = 0.013) and pTau (ρ = − 0.25; p = 0.002) related to the cognitive domain visual/verbal memory, as well as white matter hyperintensity volume and cerebral and hippocampal atrophy. In multivariable analysis, both biomarkers were independently influenced by age (T = 4.6 for pTau; T = 5.9 for NfL) and glomerular filtration rate (T = − 2.4 for pTau; T = − 3.4 for NfL). Markers of chronic heart failure, left atrial volume index (T = 4.6) and NT-proBNP (T = 2.8), were further cardiological determinants of pTau and NfL, respectively. In addition, pTau was also strongly affected by serum creatine kinase levels (T = 6.5) and ferritin (T = − 3.1). Conclusions pTau and NfL serum levels are strongly influenced by age-dependent renal and cardiac dysfunction. These findings point towards the need for longitudinal examinations and consideration of frequent comorbidities when using neuronal serum biomarkers. KW - Alzheimer’s dementia KW - heart failure KW - cognitive impairment KW - neurofilament light chain KW - phosphorylated tau protein KW - renal function KW - age Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300515 VL - 14 ER - TY - JOUR A1 - Traub, Jan A1 - Otto, Markus A1 - Sell, Roxane A1 - Homola, György A. A1 - Steinacker, Petra A1 - Oeckl, Patrick A1 - Morbach, Caroline A1 - Frantz, Stefan A1 - Pham, Mirko A1 - Störk, Stefan A1 - Stoll, Guido A1 - Frey, Anna T1 - Serum glial fibrillary acidic protein indicates memory impairment in patients with chronic heart failure JF - ESC Heart Failure N2 - Aims Cognitive dysfunction occurs frequently in patients with heart failure (HF), but early detection remains challenging. Serum glial fibrillary acidic protein (GFAP) is an emerging biomarker of cognitive decline in disorders of primary neurodegeneration such as Alzheimer's disease. We evaluated the utility of serum GFAP as a biomarker for cognitive dysfunction and structural brain damage in patients with stable chronic HF. Methods and results Using bead-based single molecule immunoassays, we quantified serum levels of GFAP in patients with HF participating in the prospective Cognition.Matters-HF study. Participants were extensively phenotyped, including cognitive testing of five separate domains and magnetic resonance imaging (MRI) of the brain. Univariable and multivariable models, also accounting for multiple testing, were run. One hundred and forty-six chronic HF patients with a mean age of 63.8 ± 10.8 years were included (15.1% women). Serum GFAP levels (median 246 pg/mL, quartiles 165, 384 pg/mL; range 66 to 1512 pg/mL) did not differ between sexes. In the multivariable adjusted model, independent predictors of GFAP levels were age (T = 5.5; P < 0.001), smoking (T = 3.2; P = 0.002), estimated glomerular filtration rate (T = −4.7; P < 0.001), alanine aminotransferase (T = −2.1; P = 0.036), and the left atrial end-systolic volume index (T = 3.4; P = 0.004). NT-proBNP but not serum GFAP explained global cerebral atrophy beyond ageing. However, serum GFAP levels were associated with the cognitive domain visual/verbal memory (T = −3.0; P = 0.003) along with focal hippocampal atrophy (T = 2.3; P = 0.025). Conclusions Serum GFAP levels are affected by age, smoking, and surrogates of the severity of HF. The association of GFAP with memory dysfunction suggests that astroglial pathologies, which evade detection by conventional MRI, may contribute to memory loss beyond ageing in patients with chronic HF. KW - Glial fibrillary acidic protein KW - GFAP KW - Chronic heart failure KW - Cognitive decline KW - Memory dysfunction KW - Brain atrophy Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-312736 VL - 9 IS - 4 ER - TY - JOUR A1 - Vogel, P. A1 - Rückert, M. A. A1 - Greiner, C. A1 - Günther, J. A1 - Reichl, T. A1 - Kampf, T. A1 - Bley, T. A. A1 - Behr, V. C. A1 - Herz, S. T1 - iMPI: portable human-sized magnetic particle imaging scanner for real-time endovascular interventions JF - Scientific Reports N2 - Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model. KW - biomedical engineering KW - electrical and electronic engineering KW - imaging KW - three-dimensional imaging Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357794 VL - 13 ER - TY - JOUR A1 - Vogel, Patrick A1 - Rückert, Martin Andreas A1 - Friedrich, Bernhard A1 - Tietze, Rainer A1 - Lyer, Stefan A1 - Kampf, Thomas A1 - Hennig, Thomas A1 - Dölken, Lars A1 - Alexiou, Christoph A1 - Behr, Volker Christian T1 - Critical Offset Magnetic PArticle SpectroScopy for rapid and highly sensitive medical point-of-care diagnostics JF - Nature Communications N2 - Magnetic nanoparticles (MNPs) have been adapted for many applications, e.g., bioassays for the detection of biomarkers such as antibodies, by controlled engineering of specific surface properties. Specific measurement of such binding states is of high interest but currently limited to highly sensitive techniques such as ELISA or flow cytometry, which are relatively inflexible, difficult to handle, expensive and time-consuming. Here we report a method named COMPASS (Critical-Offset-Magnetic-Particle-SpectroScopy), which is based on a critical offset magnetic field, enabling sensitive detection to minimal changes in mobility of MNP ensembles, e.g., resulting from SARS-CoV-2 antibodies binding to the S antigen on the surface of functionalized MNPs. With a sensitivity of 0.33 fmole/50 µl (≙7 pM) for SARS-CoV-2-S1 antibodies, measured with a low-cost portable COMPASS device, the proposed technique is competitive with respect to sensitivity while providing flexibility, robustness, and a measurement time of seconds per sample. In addition, initial results with blood serum demonstrate high specificity. KW - biochemical assays KW - characterization and analytical techniques KW - magnetic properties and materials KW - nanoparticles Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300893 VL - 13 ER - TY - JOUR A1 - Vogt, Marius L. A1 - Kollikowski, Alexander M. A1 - Weidner, Franziska A1 - Strinitz, Marc A1 - Feick, Jörn A1 - Essig, Fabian A1 - Neugebauer, Herrmann A1 - Haeusler, Karl Georg A1 - Pham, Mirko A1 - Maerz, Alexander T1 - Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke JF - Clinical Neuroradiology N2 - Background It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. Methods Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019–09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result. Results A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7%) treated with AP vs. 150 patients (50.3%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7% for AP vs. 79.3% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7% for AP and 16.0% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups. Conclusion In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness. KW - APERIO Hybrid KW - mechanical thrombectomy KW - stent-retriever device KW - stroke KW - APERIO Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-264817 VL - 32 IS - 1 ER -