TY - CHAP A1 - Werner, Rudolf A1 - Chen, Xinyu A1 - Lapa, Constantin A1 - Robinson, Simon A1 - Higuchi, Takahiro T1 - Intracellular behavior of the novel sympathetic nerve agent \(^{18}\)F-LMI1195 T2 - Journal of Nuclear Cardiology N2 - No abstract available. KW - Herz KW - PET KW - sympathetic nerve KW - autonomic nervous system KW - 18F-LMI1195 KW - positron emission tomography KW - heart KW - cardiac Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-161137 SN - 1071-3581 N1 - This is a post-peer-review, pre-copyedit version of an article published in J Nucl Cardiol. ISSN: 1071-3581. Supplement (2017) Aug;24;4: 1461-1496. The final authenticated version is available online at: http://dx.doi.org/10.1007/s12350-017-0984-y VL - 24 IS - 4 Supplement (2017) Aug ER - TY - INPR A1 - Werner, Rudolf A. A1 - Bundschuh, Ralph A. A1 - Bundschuh, Lena A1 - Javadi, Mehrbod S. A1 - Leal, Jeffrey P. A1 - Higuchi, Takahiro A1 - Pienta, Kenneth J. A1 - Buck, Andreas K. A1 - Pomper, Martin G. A1 - Gorin, Michael A. A1 - Lapa, Constantin A1 - Rowe, Steven P. T1 - Interobserver Agreement for the Standardized Reporting System PSMA-RADS 1.0 on \(^{18}\)F-DCFPyL PET/CT Imaging T2 - Journal of Nuclear Medicine N2 - Objectives: Recently, the standardized reporting and data system for prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging studies, termed PSMA-RADS version 1.0, was introduced. We aimed to determine the interobserver agreement for applying PSMA-RADS to imaging interpretation of 18F-DCFPyL PET examinations in a prospective setting mimicking the typical clinical work-flow at a prostate cancer referral center. Methods: Four readers (two experienced readers (ER, > 3 years of PSMA-targeted PET interpretation experience) and two inexperienced readers (IR, < 1 year of experience)), who had all read the initial publication on PSMA-RADS 1.0, assessed 50 18F-DCFPyL PET/computed tomography (CT) studies independently. Per scan, a maximum of 5 target lesions were selected by the observers and a PSMA-RADS score for every target lesion was recorded. No specific pre-existing conditions were placed on the selection of the target lesions, although PSMA-RADS 1.0 suggests that readers focus on the most highly avid or largest lesions. An overall scan impression based on PSMA-RADS was indicated and interobserver agreement rates on a target lesion-based, on an organ-based, and on an overall PSMA-RADS score-based level were computed. Results: The number of target lesions identified by each observer were as follows: ER 1, 123; ER 2, 134; IR 1, 123; and IR 2, 120. Among those selected target lesions, 125 were chosen by at least two individual observers (all four readers selected the same target lesion in 58/125 (46.4%) instances, three readers in 40/125 (32%) and two observers in 27/125 (21.6%) instances). The interobserver agreement for PSMA-RADS scoring among identical target lesions was good (intraclass correlation coefficient (ICC) for four, three and two identical target lesions, ≥0.60, respectively). For lymph nodes, an excellent interobserver agreement was derived (ICC=0.79). The interobserver agreement for an overall scan impression based on PSMA-RADS was also excellent (ICC=0.84), with a significant difference for ER (ICC=0.97) vs. IR (ICC=0.74, P=0.005). Conclusions: PSMA-RADS demonstrates a high concordance rate in this study, even among readers with different levels of experience. This suggests that PSMA-RADS can be effectively used for communication with clinicians and can be implemented in the collection of data for large prospective trials. KW - 18F-DCFPyL KW - Positronen-Emissions-Tomografie KW - PSMA-RADS KW - interreader KW - interobserver KW - PSMA KW - prostate cancer KW - RADS KW - reporting and data system KW - PET Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-167788 SN - 0161-5505 N1 - This research was originally published in JNM. Rudolf A. Werner, Ralph A. Bundschuh, Lena Bundschuh, Mehrbod S. Javadi, Jeffrey P. Leal, Takahiro Higuchi, Kenneth J. Pienta, Andreas K. Buck, Martin G. Pomper, Michael A. Gorin, Constantin Lapa and Steven P. Rowe. Interobserver Agreement for the Standardized Reporting System PSMA-RADS 1.0 on 18F-DCFPyL PET/CT Imaging. J Nucl Med 2018;59:1857-1864 © SNMMI. ER - TY - JOUR A1 - Serfling, Sebastian E. A1 - Lapa, Constantin A1 - Dreher, Niklas A1 - Hartrampf, Philipp E. A1 - Rowe, Steven P. A1 - Higuchi, Takahiro A1 - Schirbel, Andreas A1 - Weich, Alexander A1 - Hahner, Stefanie A1 - Fassnacht, Martin A1 - Buck, Andreas K. A1 - Werner, Rudolf A. T1 - Impact of tumor burden on normal organ distribution in patients imaged with CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT JF - Molecular Imaging and Biology N2 - Background CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs. Methods Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden. Results Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found. Conclusions In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged. KW - CXCR4 KW - C-X-C motif chemokine receptor 4 KW - PET KW - [68Ga]PentixaFor KW - [177Lu]/[90Y]PentixaTher KW - theranostics KW - endoradiotherapy Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324622 VL - 24 IS - 4 ER - TY - JOUR A1 - Israel, Ina A1 - Riehl, Gabriele A1 - Butt, Elke A1 - Buck, Andreas K. A1 - Samnick, Samuel T1 - Gallium-68-labeled KISS1-54 peptide for mapping KISS1 receptor via PET: initial evaluation in human tumor cell lines and in tumor-bearing mice JF - Pharmaceuticals N2 - Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7% radiochemical yield and at a >99% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6–4.4% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET. KW - [\(^{68}\)]KISS1-54 KW - KISS1 receptor KW - GPR54 KW - kisspeptin KW - human tumor cell lines KW - positron emission tomography KW - PET KW - KISS1-54 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-355898 SN - 1424-8247 VL - 17 IS - 1 ER - TY - JOUR A1 - Werner, Rudolf A1 - Wakabyashi, Hiroshi A1 - Chen, Xinyu A1 - Hirano, Mitsuru A1 - Shinaji, Tetsuya A1 - Lapa, Constantin A1 - Rowe, Steven A1 - Javadi, Mehrbod A1 - Higuchi, Takahiro T1 - Functional renal imaging with \(^{18}\)F-FDS PET in rat models of renal disorders JF - Journal of Nuclear Medicine N2 - Background: Precise regional quantitative assessment of renal function is limited with conventional \(^{99m}\)Tc-labeled renal radiotracers. A recent study reported that the positron emission tomography (PET) radiotracer 2-deoxy-2-(\(^{18}\)F-fluorosorbitol (\(^{18}\)F-FDS) has ideal pharmacokinetics for functional renal imaging. Furthermore, (\(^{18}\)F-FDS is available via simple reduction from routinely used 2-deoxy-2-(\(^{18}\)F-fluoro-D-glucose ((\(^{18}\)F-FDG). We aimed to further investigate the potential of (\(^{18}\)F-FDS PET as a functional renal imaging agent using rat models of kidney diseases. Methods: Two different rat models of renal impairment were investigated: Glycerol induced acute renal failure (ARF) by intramuscular administration of glycerol in hind legs and unilateral ureteral obstruction (UUO) by ligation of the left ureter. 24h after these treatments, dynamic 30 min 18F-FDS PET data were acquired using a dedicated small animal PET system. Urine 18F-FDS radioactivity 30 min after radiotracer injection was measured together with co-injected \(^{99m}\)Tc-diethylenetriaminepentaacetic acid (\(^{99m}\)Tc-DTPA) urine activity. Results: Dynamic PET imaging demonstrated rapid (\(^{18}\)F-FDS accumulation in the renal cortex and rapid radiotracer excretion via kidneys in control healthy rats. On the other hand, significantly delayed renal radiotracer uptake (continuous slow uptake) was observed in ARF rats and UUO-treated kidneys. Measured urine radiotracer concentrations of (\(^{18}\)F-FDS and \(^{99m}\)Tc-DTPA were well correlated (R=0.84, P<0.05). Conclusions: (\(^{18}\)F-FDS PET demonstrated favorable kinetics for functional renal imaging in rat models of kidney diseases. Advantages of high spatiotemporal resolution of PET imaging and simple tracer production could potentially complement or replace conventional renal scintigraphy in select cases and significantly improve the diagnostic performance of renal functional imaging. KW - unilateral ureteral obstruction KW - Nierenfunktionsstörung KW - Positronen-Emissions-Tomografie KW - 18F-FDS KW - 99mTc-DTPA KW - PET KW - renal failure KW - Glomerular filtration Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-161279 SN - 0161-5505 N1 - This research was originally published in JNM. Rudolf A. Werner, Hiroshi Wakabayashi, Xinyu Chen, Mitsuru Hirano, Tetsuya Shinaji, Constantin Lapa, Steven P. Rowe, Mehrbod S. Javadi and Takahiro Higuchi. Functional renal imaging with 18F-FDS PET in rat models of renal disorders. J Nucl Med. May 1, 2018;vol. 59 no. 5: 828-832. © SNMMI. ER - TY - THES A1 - Schadt, Fabian T1 - Entwicklung und erste Validierung eines innovativen Analysen-Tools für präklinische Bewertungen von PET-Radiopharmazeutika zur \(in\) \(vivo\) Untersuchungen neurologischer Erkrankungen T1 - Development and initial validation of an innovative analytical tool for preclinical evaluations of PET radiopharmaceuticals for \(in\) \(vivo\) investigations of neurological disease N2 - Die präklinische Forschung stellt den ersten wichtigen Meilenstein in der Klärung und Untersuchung klinisch-relevanter Erkrankungen dar. Darüber hinaus unterstützt die präklinische Forschung erheblich die Entwicklung von Therapien. Die Kleintier-Positronenemissionstomographie (µ-PET) spielt dabei eine wichtige Rolle, da sie in der Lage ist, funktionelle, physiologische und biochemische Prozesse in vivo darzustellen und zu quantifizieren. Trotz diverser etablierter PET-Datenauswertungs-Programme bleibt die Analyse von in vivo akquirierten Bilddaten aufgrund der Vielzahl an medizinischen Fragestellungen, der Komplexität der Krankheitsbilder, sowie der Etablierung neuer Radiotracer weiterhin eine große Herausforderung in der Medizin. Ziel dieser Doktorarbeit ist es daher, ein geeignetes, brauchbares Auswertungstool für eine einfache und effiziente Analyse von akquirierten µ-PET-Daten zu entwickeln und zu etablieren, welches das Spektrum bereits vorhandener Programme erweitert. Das entwickelte nuklearmedizinische Datenverarbeitungs-Analyseprogramm (engl. nuclear medicine data processing analysis tool, NU_DPA) wurde in Matlab implementiert und anhand dreier präklinischer Versuchs- bzw. Testreihen erprobt und etabliert. Bei den Datenreihen handelt es sich um µ-PET-Datensätze verschiedener Schlaganfall-Rattenhirnmodelle unter Verwendung folgender Radiotracer. Zum einen die im Gehirn homogen akkumulierende 2-[18F]Fluor-2-desoxy-glukose ([18F]FDG) zum anderen das spezifisch an P-Selektin anreichernde [68Ga]Fucoidan. Das NU_DPA umfasst die automatische Selektion des Zielvolumens (volume-of-interest, VOI) aus dem vollständigen PET-Bild und die anschließende Ausrichtung des VOI mit Hilfe eines PET-Templates (gemittelter PET-Datensatz). Dieses PET Template wird aus den eigenen akquirierten PET-Daten erstellt. Durch das Einbinden eines geeigneten anatomischen MRT-Atlas‘ (anpassbar) können die ausgerichteten PET-Daten einzelnen, Atlas-spezifischen Teilregionen zugeordnet werden. Eine solche Subklassifikation des VOI erlaubt eine genauere Betrachtung und Auswertung der Radiotracer-Akkumulation. Des Weiteren bietet NU_DPA die Möglichkeit einer semiquantitativen Auswertung der PET-Bilddaten anhand von drei unterschiedlichen Parametern, der normalisierten Aktivität, dem Standardized Uptake Value und der Uptake Ratio. Durch die Matlab-integrierten Statistik-Algorithmen ist zusätzlich eine Möglichkeit der statistischen Auswertung der zuvor berechneten Parameter gegeben. Das NU_DPA-Programm stellt somit ein semi-automatisiertes Datenauswertungs-Programm dar, das sowohl die Registrierung als auch die semiquantitative Auswertung von PET-Bilddaten innerhalb einer Versuchsreihe ermöglicht und bereits erfolgreich für die Radiotracer [18F]FDG und [68Ga]Fucoidan in Tiermodellen getestet wurde. Nach derzeitigem Kenntnisstand ist kein Datenauswertungs-Programm bekannt, das PET-Bilddaten unter Verwendung des hinzugefügten Atlas‘ semi-automatisiert analysieren kann und potenziell für homogene und Target-spezifisch akkumulierende Radiotracer geeignet ist. N2 - Preclinical research represents the first important milestone in the clarification and investigation of clinically relevant diseases. In addition, preclinical research significantly supports the development of therapies. Small animal positron emission tomography (µ-PET) plays an important role in this context, as it is able to image and quantify functional, physiological and biochemical processes in vivo. Despite various established µ-PET data analysis programs, the analysis of in vivo acquired image data remains a major challenge in medicine due to the multitude of medical questions, the complexity of disease patterns, and the establishment of new radiotracers. Therefore, the aim of this PhD thesis is to develop and establish a suitable, usable evaluation tool for a simple and efficient analysis of acquired µ-PET data, which extends the spectrum of already existing programs. The developed nuclear medicine data processing analysis tool (NU_DPA) was implemented in Matlab and tested and established on the basis of three preclinical experimental or test series. The data series are µ-PET datasets of different stroke rat brain models using the following radiotracers: 2-[18F]fluoro-2-deoxy-glucose ([18F]FDG), which accumulates homogeneously in the brain and [68Ga]fucoidan, which specifically accumulates at p-selectin. The NU_DPA involves automatic segmentation of a volume-of-interest (VOI) from the full PET image and the subsequent alignment of the VOI using a PET template (averaged PET dataset). This PET template is created from the own acquired PET data. By embedding a suitable anatomical MR atlas (customizable), the aligned PET data can be assigned to individual atlas-specific sub-regions. Such a sub-classification of the VOI allows a more detailed analysis and evaluation of the radiotracer accumulation. Furthermore, NU_DPA offers the possibility of a semi-quantitative evaluation of the PET image data based on three different parameters, the normalized activity, the standardized uptake value and the uptake ratio. The Matlab-integrated statistical algorithms provide an additional option for statistical evaluation of the previously calculated semi-quantitative parameters. The NU_DPA program thus represents a semi-automatic data evaluation program that enables both the registration and the semi-quantitative evaluation of PET image data within a series of experiments and it has already been successfully tested for the radiotracers [18F]FDG and [68Ga]fucoidan in animal models. To the best of our current knowledge, there is no known data analysis program that can semi-automatically analyze PET image data using the added atlas and is potentially suitable for homogeneous and target-specific accumulating radiotracers. KW - PET KW - Präklinische Bildgebung Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-247499 ER - TY - THES A1 - Becker, Kilian T1 - Entwicklung eines 3D-Ganzkörper-Ultraschalls an Kleintieren für morphologische Bildgebung, Volumetrie und Bildfusion mit PET T1 - Development of a 3D whole-body ultrasound in small animals for morphological imaging, volumetry and image fusion with PET N2 - Einleitung: Ultraschall wird seit mehr als 50 Jahren in der Medizin eingesetzt und ist mittlerweile ein unverzichtbares diagnostisches Verfahren, es erlaubt eine nicht-invasive Darstellung der Morphologie und Funktion von Organen in Echtzeit. In der Kleintierbildgebung dominieren bisher zur morphologischen Bildgebung Computertomographie (CT) und Magnetresonanztomographie (MRT). Daher wurde in der vorliegenden Arbeit die Idee entwickelt, die morphologischen Informationen des 3D-Ultraschalls (3D-US) für Untersuchungen an Kleintieren zu verwenden, außerdem sollten Methoden zur multimodalen Bildgebung und Bildfusion von 3D-US und Kleintier-Positronenemissionstomographie (PET) entwickelt werden. Der Vorteil des Ultraschalls gegenüber dem Kleintier-CT liegt in der fehlenden Strahlenbelastung und der guten Verfügbarkeit, was besonders für Verlaufsstudien von Interesse ist. Methoden und Ergebnisse: Zur Bildoptimierung wurde ein Fadenphantom entwickelt, welches aufgrund der feinen Strukturen die qualitative als auch quantitative Bestimmung der Auflösung ermöglicht. Die Vorarbeiten am Fadenphantom konnten exzellent die Probleme des 3D-Ultraschalls mit der achsenabhängigen Auflösung zeigen und ermöglichten eine schnelle Beurteilung der Bildqualität. Hier bestehen Einsatzmöglichkeiten in der Bewertung verschiedener Ultraschallgeräte bezüglich der Tauglichkeit für 3D-Datenaquisition. Zur reproduzierbaren Lagerung von Mäusen wurde eine Schallkopfführung ein sowohl für 3D-US als auch Kleintier-PET kompatibler Tierhalter entwickelt. Die Maus lag zur Untersuchung im angewärmten Wasserbad auf dem Tierhalter fixiert, mit Inhalationsanästhesie und Sauerstoff über eine Atemmaske versorgt. Der Zeitaufwand für eine 3D-US-Untersuchung betrug für die Akquisition etwa eine Minute. Die generierten Ultraschalldatensätze waren von guter Qualität, Strukturen wie Leber, Nieren, Blase, Wirbelsäule und Lunge konnten selbst bei kleinen Mäusen von unter 20 Gramm Körpergewicht gut dargestellt werden. Zur Validierung des 3D-Ultraschalls wurde das Volumen verschiedener Organe und Tumore bestimmt und mit dem Goldstandard verglichen. Um die Koregistrierung mit der Kleintier-PET zu ermöglichen, wurden auf dem Tierhalter drei „fiducial markers“ angebracht, die Position und Orientierung eindeutig definieren. Die Kleintier-PET-Untersuchungen wurden nach standardisierten Protokollen durchgeführt. Die anschließende Bildfusion erfolgte mittels der frei verfügbaren Software "Amide". Diskussion: Mit dem in dieser Arbeit beschriebenen Verfahren ist eine standardisierte Gewinnung von 3D-US-Datensätzen an Kleintieren möglich; zusätzlich konnte die Machbarkeit der Bildfusion mit PET-Datensätzen gezeigt werden. Der Einsatz des 3D-Ultraschalls in longitudinalen Studien, zum Beispiel zur Beurteilung der Tumorprogression, ist vorstellbar. Die Zuverlässigkeit der volumetrischen Berechnungen ist für größere Organvolumina gut, bei kleineren Volumina besteht noch Optimierungsbedarf. Weitere Verbesserungen könnten durch den Einsatz von speziellen Schallköpfen und höheren Schallfrequenzen erzielt werden. N2 - Introduction: Ultrasound has been used for more than 50 years in medicine and has become a indispensable diagnostic tool, it allows a non-invasive imaging of the morphology and function of organs in real time. Small animal morphological imaging is now dominated by CT and MRI. For present study the idea to use morphological information of the 3D-ultrasound for examination of small animals was developed, these data should be used for image fusion of 3D ultrasound and small-animal PET. The advantage of ultrasound compared to the small-animal CT is the lack of radiation exposure and the good availability, which is especially for longitudinal studies of interest. Methods and Results: For image enhancement, a thread phantom was developed, fine structures facilitate qualitative and quantitative analysis of spatial resolution. Preliminary work on the thread phantom was excellent for investigate problems of 3D ultrasound with the axis-dependent resolution. There are potential applications for evaluating different ultrasonic devices in their suitability for 3D data acquisition. For the reproducible bedding of mice a guide bar for ultrasound transducer and a compatible holder for 3D-US and PET was developed. The mouse was bedded in the heated water bath fixed to the holder, applied inhalation anesthesia and oxygen through a breathing mask. The time required for a 3D ultrasound examination was for the acquisition of about one minute. The generated ultrasound data sets were of good quality, structures such as liver, kidney, bladder, spine and lungs were even in the case of small mice of 20 gram well represented. For validation of the 3D ultrasound volumes of various organs and tumors were determined and compared with gold standard. To allow coregistration with the microPET, three "fiducial markers" were attached to define the position and orientation. PET studies were performed according to standardized protocols. The subsequent image fusion was performed using the software "amide”. Discussion: In this study a standardized procedure for 3D-US of small animals was developed, in addition, the feasibility of image fusion with PET data sets was shown. The use of 3D ultrasound in longitudinal studies, for example, to assess tumor progression, is conceivable. The reliability of the volumetric calculations is good for large organ volumes, with smaller volumes, there is still need for improvement. Further improvements could be achieved through the use of special transducers and higher ultrasound frequencies. KW - Ultraschalldiagnostik KW - Nuklearmedizin KW - Würzburg / Klinik und Poliklinik für Nuklearmedizin KW - Molekulare Bildgebung KW - 3D-Ultraschall KW - dreidimensionaler Ultraschall KW - PET KW - Positronenemissionstomographie KW - Bildfusion KW - 3D ultrasound KW - three-dimensional ultrasound KW - PET KW - positron emission tomography KW - image fusion Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-55916 ER - TY - THES A1 - Omert, Leilah Marie-Luise T1 - Einfluss systemischer Therapie auf die funktionelle Bildgebung des Multiplen Myeloms T1 - Influence of systemic therapy on functional imaging of Multiple Myeloma N2 - Das Multiple Myelom (MM) ist eine maligne hämatologische Erkrankung, die trotz großer Fortschritte in der Therapie immer noch eine schlechte Prognose hat. Bisher ist es nicht möglich, mit einem bildgebenden Verfahren alle Fragen der Diagnostik, der Stadieneinteilung, des Therapiemonitorings und der Evaluation der Prognose des Multiplen Myeloms zu klären. Da es sich beim Multiplen Myelom aber um eine stark heterogene Erkrankung handelt, die eine frühzeitige individuelle Therapie erfordert, ist es unbedingt nötig Verfahren zu entwickeln, die eine spezifische Charakterisierung der Erkrankung bei jedem einzelnen Patienten ermöglichen. In der vorliegenden Arbeit wurden die MM-Zelllinien INA-6, MM.1S und OPM-2 mit dem Proteasominhibitor MLN9708 behandelt. Behandelte und unbehandelte Zellen wurden mit dem Standardtracer 2-[18F]-Fluoro-2-Desoxy-D-Glukose (18F-FDG) oder dem in der Anwendung beim Multiplen Myelom neuen Aminosäuretracer [11C]-Methionin (11C-MET) inkubiert und die Aufnahme der Tracer zu bestimmten Zeitpunkten gemessen. Des Weiteren wurde die Ausprägung biologischer Merkmale der MM-Pathogenese bei behandelten und unbehandelten Zellen untersucht. Anschließend wurde ermittelt, ob ein Zusammenhang zwischen der Höhe der Traceraufnahme und der Ausprägung biologischer Merkmale der MM-Pathogenese bei behandelten und unbehandelten Zellen besteht. Hierdurch soll geklärt werden, ob 11C-MET besser zur Diagnostik, dem Therapiemonitoring und der Evaluation der Prognose des Multiplen Myeloms geeignet ist als der Standardtracer 18F-FDG. Es zeigte sich eine signifikant höhere 11C-MET-Aufnahme sowohl unbehandelter als auch behandelter Zellen im Vergleich zu 18F-FDG. Außerdem war eine Unterscheidung zwischen behandelten und unbehandelten Zellen mit 11C-MET besser möglich als mit 18F-FDG. Zwischen Traceraufnahme und biologischen Merkmalen der MM-Pathogenese, wie Proliferation, Expression von intrazellulären Leichtketten, CXCR4 und CD138, ergaben sich für behandelte und unbehandelte Zellen variable Zusammenhänge. Die Ergebnisse legen nahe, dass 11C-MET besser zur Diagnostik und zum Therapiemonitoring des Multiplen Myeloms geeignet ist als der Standardtracer 18F-FDG. Ob 11C-MET auch zur Stadieneinteilung und zur Evaluation der Prognose des Multiplen Myeloms besser geeignet ist als 18F-FDG, muss in weiteren Studien untersucht werden. N2 - Despite new therapies Multiple Myeloma (MM) remains a hematologic malignancy with poor prognosis. Because of marked disease heterogeneity outcomes are extremely variable. The role of functional imaging, such as positron emission tomography for diagnosis, therapy monitoring, staging and prognostication is being investigated for a few years. This study evaluated the radiotracers 11C-Methionine (paraprotein-biosynthesis) and 18F-FDG (glucose-utilization) for diagnosis, therapy monitoring, staging and outcome prediction of MM. Influence of proteasome-inhibitor MLN9708 (Ixazomib) on radiotracer-uptake of different MM cell-lines was analyzed and related to tumor-biology. Both untreated and treated MM cells significantly took up more 11C-Methionine than 18F-FDG. Discrimination of treated and untreated cells was only possible with 11C-Methionine. Correlations between tracer uptake and tumor biology were variable for both tracers. These results suggest that 11C-Methionine is superior to 18F-FDG in diagnosis and therapy monitoring of MM. The suitability of 11C-Methionine for staging and prognostication has to be evaluated in further studies. KW - Multiples Myelom KW - Bildgebung KW - PET Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-154793 ER - TY - THES A1 - Herterich, Theresia Margarete Barbara T1 - Die Wertigkeit der PET/CT in der Detektion zervikaler Lymphknotenmetastasen beim oralen Plattenepithelkarzinom T1 - The value of PET/CT in the detection of cervical lymph node metastases in oral squamous cell carcinoma N2 - Das orale Plattenepithelkarzinom zählt zu den häufigen Krebserkrankungen in Deutschland. Das Vorhandensein von zervikalen Lymphknotenmetastasen ist dabei einer der wichtigsten prognostischen Faktoren. Für die Therapieplanung ist eine zuverlässige präoperative Diagnostik unerlässlich. Etablierte bildgebende Stagingverfahren (Sonographie, MRT, CT) orientieren sich allein an morphologischen Kriterien. Die PET/CT verspricht durch die Kombination funktioneller und morphologischer Verfahren die Detektion lymphoregionärer Metastasen. Ein weiterer Vorteil scheint der Nachweis simultaner Zweitmalignome und Fernmetastasen zu sein. 135 Patienten mit einem primären oralen Plattenepithelkarzinom erhielten im Rahmen der präoperativen Staginguntersuchungen eine PET/CT-Untersuchung. Untersucht wurde der korrekte Nachweis (Sensitivität) bzw. Ausschluss (Spezifität) zervikaler Lymphknotenmetastasen sowie die Detektion (Trefferquote) von simultanen Zweitmalignomen durch die PET/CT. Die PET/CT zeigte eine Sensitivität von 82,9 % und eine Spezifität von 84 %. Simultane Zweitmalignome wurden mit einer Trefferquote von 62,5 % durch die PET/CT erkannt. Das diagnostische Potenzial konnte in unserer Studie bestätigt werden. Vergleichende Studien zu den etablierten bildgebenden Verfahren wären wünschenswert. N2 - Oral squamous cell carcinoma is one of the most common cancers in Germany. The presence of cervical lymph node metastases is one of the most important prognostic factors. Reliable preoperative diagnostics are essential for therapy planning. Established imaging staging methods (sonography, MRI, CT) are based solely on morphological criteria. PET/CT promises the detection of lymphoregional metastases by combining functional and morphological methods. Another advantage seems to be the detection of simultaneous secondary malignancies and distant metastases. 135 patients with primary oral squamous cell carcinoma received a PET/CT scan as part of the preoperative staging examinations. The correct detection (sensitivity) or exclusion (specificity) of cervical lymph node metastases as well as the detection (hit rate) of simultaneous second malignancies by PET/CT were investigated. PET/CT showed a sensitivity of 82.9% and a specificity of 84%. Simultaneous second malignancies were detected by PET/CT with a hit rate of 62.5%. The diagnostic potential was confirmed in our study. Comparative studies on the established imaging techniques would be desirable. KW - Emissions-Computertomographie KW - Lymphknotenmetastase KW - PET/CT KW - zervikale Lymphknotenmetastasen KW - orales Plattenepithelkarzinom KW - Mundhöhlenkrebs KW - Mundhöhlenkarzinom KW - PET Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-314021 ER - TY - JOUR A1 - Schadt, Fabian A1 - Israel, Ina A1 - Samnick, Samuel T1 - Development and Validation of a Semi-Automated, Preclinical, MRI-Template Based PET Image Data Analysis Tool for Rodents JF - Frontiers in Neuroinformatics N2 - AimIn PET imaging, the different types of radiotracers and accumulations, as well as the diversity of disease patterns, make the analysis of molecular imaging data acquired in vivo challenging. Here, we evaluate and validate a semi-automated MRI template-based data analysis tool that allows preclinical PET images to be aligned to a self-created PET template. Based on the user-defined volume-of-interest (VOI), image data can then be evaluated using three different semi-quantitative parameters: normalized activity, standardized uptake value, and uptake ratio. Materials and MethodsThe nuclear medicine Data Processing Analysis tool (NU_DPA) was implemented in Matlab. Testing and validation of the tool was performed using two types of radiotracers in different kinds of stroke-related brain diseases in rat models. The radiotracers used are 2-[\(^{18}\)F]fluoro-2-deoxyglucose ([\(^{18}\)F]FDG), a metabol\(^{68}\)Ga]Ga-Fucoidan, a target-selective radioligand specifically binding to p-selectin. After manual image import, the NU_DPA tool automatically creates an averaged PET template out of the acquired PET images, to which all PET images are then aligned onto. The added MRI template-based information, resized to the lower PET resolution, defines the VOI and also allows a precise subdivision of the VOI into individual sub-regions. The aligned PET images can then be evaluated semi-quantitatively for all regions defined in the MRI atlas. In addition, a statistical analysis and evaluation of the semi-quantitative parameters can then be performed in the NU_DPA tool. ResultsUsing ischemic stroke data in Wistar rats as an example, the statistical analysis of the tool should be demonstrated. In this [\(^{18}\)F]FDG-PET experiment, three different experimental states were compared: healthy control state, ischemic stroke without electrical stimulation, ischemic stroke with electrical stimulation. Thereby, statistical data evaluation using the NU_DPA tool showed that the glucose metabolism in a photothrombotic lesion can be influenced by electrical stimulation. ConclusionOur NU_DPA tool allows a very flexible data evaluation of small animal PET data in vivo including statistical data evaluation. Using the radiotracers [\(^{18}\)F]FDG and [\(^{68}\)Ga]Ga-Fucoidan, it was shown that the semi-automatic MRI-template based data analysis of the NU_DPA tool is potentially suitable for both metabolic radiotracers as well as target-selective radiotracers. KW - data analysis KW - Matlab KW - MRI KW - PET KW - positron emission tomography KW - preclinical imaging Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-240289 SN - 1662-5196 VL - 15 ER -