TY - JOUR A1 - Helmer, Philipp A1 - Hottenrott, Sebastian A1 - Rodemers, Philipp A1 - Leppich, Robert A1 - Helwich, Maja A1 - Pryss, Rüdiger A1 - Kranke, Peter A1 - Meybohm, Patrick A1 - Winkler, Bernd E. A1 - Sammeth, Michael T1 - Accuracy and Systematic Biases of Heart Rate Measurements by Consumer-Grade Fitness Trackers in Postoperative Patients: Prospective Clinical Trial JF - Journal of Medical Internet Research N2 - Background: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports. Objective: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date. Methods: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography). Results: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute). Conclusions: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate. KW - Withings ScanWatch KW - health tracker KW - smartwatch KW - internet of things KW - personalized medicine KW - photoplethysmography KW - wearable KW - Garmin Fenix 6 Pro KW - Apple Watch 7 KW - Fitbit Sense Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-299679 VL - 24 IS - 12 ER - TY - JOUR A1 - Düking, Peter A1 - Giessing, Laura A1 - Frenkel, Marie Ottilie A1 - Koehler, Karsten A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study JF - JMIR mhealth and uhealth N2 - Background: Physical activity reduces the incidences of noncommunicable diseases, obesity, and mortality, but an inactive lifestyle is becoming increasingly common. Innovative approaches to monitor and promote physical activity are warranted. While individual monitoring of physical activity aids in the design of effective interventions to enhance physical activity, a basic prerequisite is that the monitoring devices exhibit high validity. Objective: Our goal was to assess the validity of monitoring heart rate (HR) and energy expenditure (EE) while sitting or performing light-to-vigorous physical activity with 4 popular wrist-worn wearables (Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa). Methods: While wearing the 4 different wearables, 25 individuals performed 5 minutes each of sitting, walking, and running at different velocities (ie, 1.1 m/s, 1.9 m/s, 2.7 m/s, 3.6 m/s, and 4.1 m/s), as well as intermittent sprints. HR and EE were compared to common criterion measures: Polar-H7 chest belt for HR and indirect calorimetry for EE. Results: While monitoring HR at different exercise intensities, the standardized typical errors of the estimates were 0.09-0.62, 0.13-0.88, 0.62-1.24, and 0.47-1.94 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 0.9%-4.3%, 2.2%-6.7%, 2.9%-9.2%, and 4.1%-19.1%, respectively, for the 4 wearables. While monitoring EE at different exercise intensities, the standardized typical errors of the estimates were 0.34-1.84, 0.32-1.33, 0.46-4.86, and 0.41-1.65 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 13.5%-27.1%, 16.3%-28.0%, 15.9%-34.5%, and 8.0%-32.3%, respectively. Conclusions: The Apple Watch Series 4 provides the highest validity (ie, smallest error rates) when measuring HR while sitting or performing light-to-vigorous physical activity, followed by the Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, in that order. The Apple Watch Series 4 and Polar Vantage V are suitable for valid HR measurements at the intensities tested, but HR data provided by the Garmin Fenix 5 and Fitbit Versa should be interpreted with caution due to higher error rates at certain intensities. None of the 4 wrist-worn wearables should be employed to monitor EE at the intensities and durations tested." KW - cardiorespiratory fitness KW - innovation KW - smartwatch KW - technology KW - wearable KW - digital health Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229413 VL - 8 IS - 5 ER - TY - JOUR A1 - Davidson, Padraig A1 - Düking, Peter A1 - Zinner, Christoph A1 - Sperlich, Billy A1 - Hotho, Andreas T1 - Smartwatch-Derived Data and Machine Learning Algorithms Estimate Classes of Ratings of Perceived Exertion in Runners: A Pilot Study JF - Sensors N2 - The rating of perceived exertion (RPE) is a subjective load marker and may assist in individualizing training prescription, particularly by adjusting running intensity. Unfortunately, RPE has shortcomings (e.g., underreporting) and cannot be monitored continuously and automatically throughout a training sessions. In this pilot study, we aimed to predict two classes of RPE (≤15 “Somewhat hard to hard” on Borg’s 6–20 scale vs. RPE >15 in runners by analyzing data recorded by a commercially-available smartwatch with machine learning algorithms. Twelve trained and untrained runners performed long-continuous runs at a constant self-selected pace to volitional exhaustion. Untrained runners reported their RPE each kilometer, whereas trained runners reported every five kilometers. The kinetics of heart rate, step cadence, and running velocity were recorded continuously ( 1 Hz ) with a commercially-available smartwatch (Polar V800). We trained different machine learning algorithms to estimate the two classes of RPE based on the time series sensor data derived from the smartwatch. Predictions were analyzed in different settings: accuracy overall and per runner type; i.e., accuracy for trained and untrained runners independently. We achieved top accuracies of 84.8 % for the whole dataset, 81.8 % for the trained runners, and 86.1 % for the untrained runners. We predict two classes of RPE with high accuracy using machine learning and smartwatch data. This approach might aid in individualizing training prescriptions. KW - artificial intelligence KW - endurance KW - exercise intensity KW - precision training KW - prediction KW - wearable Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-205686 SN - 1424-8220 VL - 20 IS - 9 ER - TY - JOUR A1 - Düking, Peter A1 - Tafler, Marie A1 - Wallmann-Sperlich, Birgit A1 - Sperlich, Billy A1 - Kleih, Sonja T1 - Behavior Change Techniques in Wrist-Worn Wearables to Promote Physical Activity: Content Analysis JF - JMIR Mhealth and Uhealth N2 - Background: Decreasing levels of physical activity (PA) increase the incidences of noncommunicable diseases, obesity, and mortality. To counteract these developments, interventions aiming to increase PA are urgently needed. Mobile health (mHealth) solutions such as wearable sensors (wearables) may assist with an improvement in PA. Objective: The aim of this study is to examine which behavior change techniques (BCTs) are incorporated in currently available commercial high-end wearables that target users’ PA behavior. Methods: The BCTs incorporated in 5 different high-end wearables (Apple Watch Series 3, Garmin Vívoactive 3, Fitbit Versa, Xiaomi Amazfit Stratos 2, and Polar M600) were assessed by 2 researchers using the BCT Taxonomy version 1 (BCTTv1). Effectiveness of the incorporated BCTs in promoting PA behavior was assessed by a content analysis of the existing literature. Results: The most common BCTs were goal setting (behavior), action planning, review behavior goal(s), discrepancy between current behavior and goal, feedback on behavior, self-monitoring of behavior, and biofeedback. Fitbit Versa, Garmin Vívoactive 3, Apple Watch Series 3, Polar M600, and Xiaomi Amazfit Stratos 2 incorporated 17, 16, 12, 11, and 11 BCTs, respectively, which are proven to effectively promote PA. Conclusions: Wearables employ different numbers and combinations of BCTs, which might impact their effectiveness in improving PA. To promote PA by employing wearables, we encourage researchers to develop a taxonomy specifically designed to assess BCTs incorporated in wearables. We also encourage manufacturers to customize BCTs based on the targeted populations. KW - cardiorespiratory fitness KW - innovation KW - smartwatch KW - technology KW - wearable KW - eHealth KW - mHealth Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230556 VL - 8 IS - 11 ER - TY - JOUR A1 - Düking, Peter A1 - Zinner, Christoph A1 - Reed, Jennifer L. A1 - Holmberg, Hans‐Christer A1 - Sperlich, Billy T1 - Predefined vs data‐guided training prescription based on autonomic nervous system variation: A systematic review JF - Scandinavian Journal of Medicine & Science in Sports N2 - Monitoring variations in the functioning of the autonomic nervous system may help personalize training of runners and provide more pronounced physiological adaptations and performance improvements. We systematically reviewed the scientific literature comparing physiological adaptations and/or improvements in performance following training based on responses of the autonomic nervous system (ie, changes in heart rate variability) and predefined training. PubMed, SPORTDiscus, and Web of Science were searched systematically in July 2019. Keywords related to endurance, running, autonomic nervous system, and training. Studies were included if they (a) involved interventions consisting predominantly of running training; (b) lasted at least 3 weeks; (c) reported pre‐ and post‐intervention assessment of running performance and/or physiological parameters; (d) included an experimental group performing training adjusted continuously on the basis of alterations in HRV and a control group; and (e) involved healthy runners. Five studies involving six interventions and 166 participants fulfilled our inclusion criteria. Four HRV‐based interventions reduced the amount of moderate‐ and/or high‐intensity training significantly. In five interventions, improvements in performance parameters (3000 m, 5000 m, Loadmax, Tlim) were more pronounced following HRV‐based training. Peak oxygen uptake (VO\(_{2peak}\)) and submaximal running parameters (eg, LT1, LT2) improved following both HRV‐based and predefined training, with no clear difference in the extent of improvement in VO\(_{2peak}\). Submaximal running parameters tended to improve more following HRV‐based training. Research findings to date have been limited and inconsistent. Both HRV‐based and predefined training improve running performance and certain submaximal physiological adaptations, with effects of the former training tending to be greater. KW - cardiorespiratory fitness KW - eHealth KW - endurance KW - innovation KW - technology KW - training KW - wearable Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217893 VL - 30 IS - 12 SP - 2291 EP - 2304 ER - TY - JOUR A1 - Sperlich, Billy A1 - Hahn, Lea-Sofie A1 - Edel, Antonia A1 - Behr, Tino A1 - Helmprobst, Julian A1 - Leppich, Robert A1 - Wallmann-Sperlich, Birgit A1 - Holmberg, Hans-Christer T1 - A 4-week intervention involving mobile-based daily 6-minute micro-sessions of functional high-intensity circuit training improves strength and quality of life, but not cardio-respiratory fitness of young untrained adults JF - Frontiers in Physiology N2 - The present study was designed to assess the psycho-physiological responses of physically untrained individuals to mobile-based multi-stimulating, circuit-like, multiple-joint conditioning (Circuit\(_{HIIT}\)) performed either once (1xCircuitHIIT) or twice (2xCircuit\(_{HIIT}\)) daily for 4 weeks. In this single-center, two-arm randomized, controlled study, 24 men and women (age: 25 ± 5 years) first received no training instructions for 4 weeks and then performed 4 weeks of either 1xCircuitHIIT or 2xCircuit\(_{HIIT}\) (5 men and 7 women in each group) daily. The 1xCircuitHIIT and 2xCircuit\(_{HIIT}\) participants carried out 90.7 and 85.7% of all planned training sessions, respectively, with average heart rates during the 6-min sessions of 74.3 and 70.8% of maximal heart rate. Body, fat and fat-free mass, and metabolic rate at rest did not differ between the groups or between time-points of measurement. Heart rate while running at 6 km⋅h\(^{-1}\) declined after the intervention in both groups. Submaximal and peak oxygen uptake, the respiratory exchange ratio and heart rate recovery were not altered by either intervention. The maximal numbers of push-ups, leg-levers, burpees, 45°-one-legged squats and 30-s skipping, as well as perception of general health improved in both groups. Our 1xCircuit\(_{HIIT}\) or 2xCircuit\(_{HIIT}\) interventions improved certain parameters of functional strength and certain dimensions of quality of life in young untrained individuals. However, they were not sufficient to enhance cardio-respiratory fitness, in particular peak oxygen uptake. KW - aerobic fitness KW - body composition KW - functional training KW - mHealth KW - power training KW - V800 KW - wearable KW - web-based apps Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176565 VL - 9 IS - 423 ER - TY - JOUR A1 - Sperlich, Billy A1 - Becker, Martin A1 - Hotho, Andreas A1 - Wallmann-Sperlich, Birgit A1 - Sareban, Mahdi A1 - Winkert, Kay A1 - Steinacker, Jürgen M. A1 - Treff, Gunnar T1 - Sedentary behavior among national elite rowers during off-training — a pilot study JF - Frontiers in Physiology N2 - The aim of this pilot study was to analyze the off-training physical activity (PA) profile in national elite German U23 rowers during 31 days of their preparation period. The hours spent in each PA category (i.e., sedentary: <1.5 metabolic equivalents (MET); light physical activity: 1.5–3 MET; moderate physical activity: 3–6 MET and vigorous intense physical activity: >6 MET) were calculated for every valid day (i.e., >480 min of wear time). The off-training PA during 21 weekdays and 10 weekend days of the final 11-week preparation period was assessed by the wrist-worn multisensory device Microsoft Band II (MSBII). A total of 11 rowers provided valid data (i.e., >480 min/day) for 11.6 week days and 4.8 weekend days during the 31 days observation period. The average sedentary time was 11.63 ± 1.25 h per day during the week and 12.49 ± 1.10 h per day on the weekend, with a tendency to be higher on the weekend compared to weekdays (p = 0.06; d = 0.73). The average time in light, moderate and vigorous PA during the weekdays was 1.27 ± 1.15, 0.76 ± 0.37, 0.51 ± 0.44 h per day, and 0.67 ± 0.43, 0.59 ± 0.37, 0.53 ± 0.32 h per weekend day. Light physical activity was higher during weekdays compared to the weekend (p = 0.04; d = 0.69). Based on our pilot study of 11 national elite rowers we conclude that rowers display a considerable sedentary off-training behavior of more than 11.5 h/day. KW - recovery KW - sedentary behavior KW - accelerometer KW - microsoft band 2 KW - multi-sensor KW - wearable Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158753 VL - 8 IS - 655 ER -