TY - JOUR A1 - Üçeyler, Nurcan A1 - Homola, György A. A1 - González, Hans Guerrero A1 - Kramer, Daniela A1 - Wanner, Christoph A1 - Weidemann, Frank A1 - Solymosi, László A1 - Sommer, Claudia T1 - Increased Arterial Diameters in the Posterior Cerebral Circulation in Men with Fabry Disease N2 - A high load of white matter lesions and enlarged basilar arteries have been shown in selected patients with Fabry disease, a disorder associated with an increased stroke risk. We studied a large cohort of patients with Fabry disease to differentially investigate white matter lesion load and cerebral artery diameters. We retrospectively analyzed cranial magnetic resonance imaging scans of 87 consecutive Fabry patients, 20 patients with ischemic stroke, and 36 controls. We determined the white matter lesion load applying the Fazekas score on fluid-attenuated inversion recovery sequences and measured the diameters of cerebral arteries on 3D-reconstructions of the time-of-flight-MR-angiography scans. Data of different Fabry patient subgroups (males – females; normal – impaired renal function) were compared with data of patients with stroke and controls. A history of stroke or transient ischemic attacks was present in 4/30 males (13%) and 5/57 (9%) females with Fabry disease, all in the anterior circulation. Only one man with Fabry disease showed confluent cerebral white matter lesions in the Fazekas score assessment (1%). Male Fabry patients had a larger basilar artery (p<0.01) and posterior cerebral artery diameter (p<0.05) compared to male controls. This was independent of disease severity as measured by renal function and did not lead to changes in arterial blood flow properties. A basilar artery diameter of >3.2 mm distinguished between men with Fabry disease and controls (sensitivity: 87%, specificity: 86%, p<0.001), but not from stroke patients. Enlarged arterial diameters of the posterior circulation are present only in men with Fabry disease independent of disease severity. KW - Arterial Diameters KW - ischemic stroke KW - magnetic resonance imaging KW - stroke KW - cerebral arteries KW - renal system KW - central nervous system KW - blood flow KW - lesions Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-112614 ER - TY - JOUR A1 - Zhou, Xiang A1 - Dierks, Alexander A1 - Kertels, Olivia A1 - Samnick, Samuel A1 - Kircher, Malte A1 - Buck, Andreas K. A1 - Haertle, Larissa A1 - Knorz, Sebastian A1 - Böckle, David A1 - Scheller, Lukas A1 - Messerschmidt, Janin A1 - Barakat, Mohammad A1 - Truger, Marietta A1 - Haferlach, Claudia A1 - Einsele, Hermann A1 - Rasche, Leo A1 - Kortüm, K. Martin A1 - Lapa, Constantin T1 - The link between cytogenetics/genomics and imaging patterns of relapse and progression in patients with relapsed/refractory multiple myeloma: a pilot study utilizing 18F-FDG PET/CT JF - Cancers N2 - Utilizing 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT), we performed this pilot study to evaluate the link between cytogenetic/genomic markers and imaging patterns in relapsed/refractory (RR) multiple myeloma (MM). We retrospectively analyzed data of 24 patients with RRMM who were treated at our institution between November 2018 and February 2020. At the last relapse/progression, patients had been treated with a median of three (range 1–10) lines of therapy. Six (25%) patients showed FDG avid extramedullary disease without adjacency to bone. We observed significantly higher maximum standardized uptake values (SUV\(_{max}\)) in patients harboring del(17p) compared with those without del(17p) (p = 0.025). Moreover, a high SUV\(_{max}\) of >15 indicated significantly shortened progression-free survival (PFS) (p = 0.01) and overall survival (OS) (p = 0.0002). One female patient exhibited biallelic TP53 alteration, i.e., deletion and mutation, in whom an extremely high SUV\(_{max}\) of 37.88 was observed. In summary, this pilot study suggested a link between del(17p)/TP53 alteration and high SUV\(_{max}\) on 18F-FDG PET/CT in RRMM patients. Further investigations are highly warranted at this point. KW - radiogenomics KW - 18F-FDG PET/CT KW - multiple myeloma KW - relapse KW - progression KW - pattern Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-211157 SN - 2072-6694 VL - 12 IS - 9 ER - TY - JOUR A1 - Zhou, Xiang A1 - Dierks, Alexander A1 - Kertels, Olivia A1 - Kircher, Malte A1 - Schirbel, Andreas A1 - Samnick, Samuel A1 - Buck, Andreas K. A1 - Knorz, Sebastian A1 - Böckle, David A1 - Scheller, Lukas A1 - Messerschmidt, Janin A1 - Barakat, Mohammad A1 - Kortüm, K. Martin A1 - Rasche, Leo A1 - Einsele, Hermann A1 - Lapa, Constantin T1 - 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor PET/CT in patients with smoldering multiple myeloma: imaging pattern and clinical features JF - Cancers N2 - This study aimed to explore the correlation between imaging patterns and clinical features in patients with smoldering multiple myeloma (SMM) who simultaneously underwent 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT). We retrieved and analyzed clinical characteristics and PET imaging data of 10 patients with SMM. We found a significant correlation between bone marrow (BM) plasma cell (PC) infiltration and mean standardized uptake values (SUV\(_{mean}\)) of lumbar vertebrae L2-L4 on 11C-Methionine PET/CT scans (r = 0.676, p = 0.031) and 68Ga-Pentixafor PET/CT scans (r = 0.839, p = 0.002). However, there was no significant correlation between BM involvement and SUV\(_{mean}\) of lumbar vertebrae L2-L4 on 18F-FDG PET/CT scans (r = 0.558, p = 0.093). Similarly, mean target-to-background ratios (TBR\(_{mean}\)) of lumbar vertebrae L2-L4 also correlated with bone marrow plasma cell (BMPC) infiltration in 11C-Methionine PET/CT (r = 0.789, p = 0.007) and 68Ga-Pentixafor PET/CT (r = 0.724, p = 0.018) PET/CT. In contrast, we did not observe a significant correlation between BMPC infiltration rate and TBR\(_{mean}\) in 18F-FDG PET/CT (r = 0.355, p = 0.313). Additionally, on 11C-Methionine PET/CT scans, we found a significant correlation between BMPC infiltration and TBR\(_{max}\) of lumbar vertebrae L2-L4 (r = 0.642, p = 0.045). In conclusion, 11C-Methionine and 68Ga-Pentixafor PET/CT demonstrate higher sensitivity than 18F-FDG PET/CT in detecting BM involvement in SMM. KW - 18F-FDG PET/CT KW - 11C-Methionine PET/CT KW - 68Ga-Pentixafor PET/CT KW - smoldering myeloma Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-211240 SN - 2072-6694 VL - 12 IS - 8 ER - TY - JOUR A1 - Zeller, Mario A1 - Müller, Alexander A1 - Gutberlet, Marcel A1 - Nichols, Thomas A1 - Hahn, Dietbert A1 - Köstler, Herbert A1 - Bartsch, Andreas J. T1 - Boosting BOLD fMRI by K-Space Density Weighted Echo Planar Imaging JF - PLoS ONE N2 - Functional magnetic resonance imaging (fMRI) has become a powerful and influential method to non-invasively study neuronal brain activity. For this purpose, the blood oxygenation level-dependent (BOLD) effect is most widely used. T2* weighted echo planar imaging (EPI) is BOLD sensitive and the prevailing fMRI acquisition technique. Here, we present an alternative to its standard Cartesian recordings, i.e. k-space density weighted EPI, which is expected to increase the signal-to-noise ratio in fMRI data. Based on in vitro and in vivo pilot measurements, we show that fMRI by k-space density weighted EPI is feasible and that this new acquisition technique in fact boosted spatial and temporal SNR as well as the detection of local fMRI activations. Spatial resolution, spatial response function and echo time were identical for density weighted and conventional Cartesian EPI. The signal-to-noise ratio gain of density weighting can improve activation detection and has the potential to further increase the sensitivity of fMRI investigations. KW - data acquisition KW - density KW - echo planar imaging KW - functional magnetic resonance imaging KW - imaging techniques KW - matched filters KW - signal filtering KW - statistical data Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-97233 ER - TY - THES A1 - Zeller, Mario T1 - Dichtegewichtete Magnetresonanz-Bildgebung mit Multi-Echo-Sequenzen T1 - Density Weighted Magnetic Resonance Imaging with Multi-Echo Sequences N2 - Das Signal-zu-Rausch-Verhältnis (SNR) stellt bei modernen Bildgebungstechniken in der Magnetresonanz-Tomographie heutzutage oftmals die entscheidende Limitation dar. Eine Verbesserung durch Modifikation der Hardware ist kostspielig und führt meistens zu einer Verstärkung anderer Probleme, wie zum Beispiel erhöhte Energiedeposition ins Gewebe. Im Gegensatz dazu ist Dichtegewichtung eine Methode, die eine SNR-Erhöhung durch Modifikation der Aufnahmetechnik ermöglicht. In der MR-Bildgebung erfolgt oftmals eine retrospektive Filterung des aufgenommenen Signalverlaufs, beispielsweise zur Artefaktreduktion. Damit einhergehend findet eine Veränderung der Modulationstransferfunktion (MTF) bzw. ihrer Fouriertransformierten, der räumlichen Antwortfunktion (SRF), statt. Optimales SNR wird nach dem Matched Filter-Theorem erzielt, wenn die nachträgliche Filterung dem aufgenommenen Signalverlauf proportional ist. Dies steht dem Ziel der Artefaktreduktion entgegen. Bei Dichtegewichtung steht durch nicht-kartesische Abtastung des k-Raums mit der k-Raum-Dichte ein zusätzlicher Freiheitsgrad zur Verfügung. Dieser ermöglicht es, im Falle eines konstanten Signalverlaufs eine gewünschte MTF ohne Filterung zu erreichen. Bei veränderlichem Signalverlauf kann ein SNR Matched Filter angewendet werden, dessen negative Einflüsse auf die MTF durch Dichtegewichtung kompensiert werden. Somit ermöglicht Dichtegewichtung eine vorgegebene MTF und gleichzeitig ein optimales SNR. In der vorliegenden Arbeit wurde Dichtegewichtung erstmals bei den schnellen Multi-Echo-Sequenzen Turbo-Spin-Echo und Echoplanar-Bildgebung (EPI) angewendet. Im Gegensatz zu bisherigen Implementierungen muss hier der Signalabfall durch T2- bzw. T2*-Relaxation berücksichtigt werden. Dies führt dazu, dass eine prospektiv berechnete dichtegewichtete Verteilung nur bei einer Relaxationszeit optimal ist. Bei Geweben mit abweichenden Relaxationszeiten können sich wie auch bei den kartesischen Varianten dieser Sequenzen Änderungen an SRF und SNR ergeben. Bei dichtegewichteter Turbo-Spin-Echo-Bildgebung des Gehirns konnte mit den gewählten Sequenzparametern ein SNR-Vorteil von 43 % gegenüber der kartesischen Variante erzielt werden. Die Akquisition wurde dabei auf die T2-Relaxationszeit von weißer Substanz optimiert. Da die meisten Gewebe im Gehirn eine ähnliche Relaxationszeit aufweisen, blieb der visuelle Gesamteindruck identisch zur kartesischen Bildgebung. Der SNR-Gewinn konnte in der dichtegewichteten Implementierung zur Messzeithalbierung genutzt werden. Dichtegewichtete EPI weist eine hohe Anfälligkeit für geometrische Verzerrungen, welche durch Inhomogenitäten des Hauptmagnetfeldes verursacht werden, auf. Die Verzerrungen konnten erfolgreich mit einer Conjugate Phase-Methode korrigiert werden. Dazu muss die räumliche Verteilung der Feldinhomogenitäten bekannt sein. Dazu ist zusätzlich zur eigentlichen EPI-Aufnahme die zeitaufwendige Aufnahme einer sogenannten Fieldmap erforderlich. Im Rahmen dieser Arbeit konnte eine Methode entwickelt werden, welche die zur Erlangung einer Fieldmap notwendige Aufnahmedauer auf wenige Sekunden reduziert. Bei dieser Art der Fieldmap-Aufnahme müssen jedoch durch Atmung hervorgerufene Effekte auf die Bildphase berücksichtigt werden. Die Fieldmap-Genauigkeit kann durch Aufnahme unter Atempause, Mittelung oder retrospektiver Phasenkorrektur erhöht werden. Für die gewählten EPI-Sequenzparameter wurde mit Dichtegewichtung gegenüber der kartesischen Variante ein SNR-Gewinn von 14 % erzielt. Anhand einer funktionellen MRT (fMRI)-Fingertapping-Studie konnte demonstriert werden, dass die SNR-Steigerung auch zu einer signifikant erhöhten Aktivierungsdetektion in Teilen der Hirnareale führt, die bei der Fingerbewegung involviert sind. Die Verwendung von zusätzlicher EPI-Phasenkorrektur und iterativer Optimierung der dichtegewichteten k-Raum-Abtastung führt zu weiteren Verbesserungen der dichtegewichteten Bildgebung mit Multi-Echo-Sequenzen. N2 - Magnetic resonance imaging (MRI) is often limited by the signal to noise ratio (SNR). In standard Cartesian acquisition methods, the SNR can be improved by applying a so-called matched filter to the acquired raw data, which correlates with the anticipated signal profile. Unfortunately, this filter changes the spatial response function (SRF), which characterizes the imaging properties of the imaging method, in an undesired way. For example, a matched filter often amplifies undesired image artifacts and is thus normally omitted. In contrast, filters which change the SRF are typically applied, e.g., for artifact reduction. These however do not provide an optimal SNR. Density weighting is a method which allows a desired SRF and an optimal SNR at the same time. This is achieved by introducing a new degree of freedom to the SRF; the density of the acquisition steps in k-space. In this work, density weighting was adapted to turbo spin echo (TSE) and echo planar imaging (EPI). In contrast to earlier implementations of density weighting, signal relaxation has to be taken into consideration with these multi-echo sequences. As a result, the desired SRF and SNR are only obtained for one prospectively determined relaxation time. For deviating relaxation times, changes in SRF and SNR may occur. In density weighted TSE brain imaging, an average SNR gain of 43 % over Cartesian imaging could be achieved for the chosen sequence parameters. The density weighted acquisition was optimized for the T2 relaxation time of white matter. Since the relaxation times of most other tissues in the brain did not significantly differ, the overall visual impression of density weighted and Cartesian images was identical. The achieved SNR gain could be used to halve the acquisition time of the density weighted implementation. Density weighted EPI is especially prone to geometric distortions caused by inhomogeneities of the main magnetic field. The distortions could be successfully corrected with a conjugate phase method. For these methods, a time-consuming acquisition of a so-called field map is typically required. A method could be developed which greatly reduces the field map acquisition time to a few seconds. It was found that phase changes caused by respiration influence the field map accuracy of this and similar methods. A significantly higher accuracy could be achieved by an acquisition under breath-hold or by retrospective phase correction or averaging. It was demonstrated in an fMRI group study that an average SNR gain of 14 % for density weighted EPI resulted in an increased detection power in the activated brain areas. First results involving additional EPI phase correction and iterative k-space sampling optimization demonstrate further improvements of density weighted imaging with multi-echo sequences. KW - Kernspintomografie KW - Störabstand KW - Dichtegewichtung KW - Echoplanar-Bildgebung KW - Turbo Spin Echo KW - B0-Korrektur KW - Density Weighting KW - Point Spread Function KW - Echo Planar Imaging KW - Turbo Spin Echo KW - B0 correction KW - Echo planar imaging KW - NMR-Tomographie Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-84142 ER - TY - JOUR A1 - Zeller, Daniel A1 - Heidemeier, Anke A1 - Grigoleit, Götz Ulrich A1 - Müllges, Wolfgang T1 - Case report: subacute tetraplegia in an immunocompromised patient JF - BMC Neurology N2 - Background: Clinical reasoning in Neurology is based on general associations which help to deduce the site of the lesion. However, even “golden principles” may occasionally be deceptive. Here, we describe the case of subacute flaccid tetraparesis due to motor cortical lesions. To our knowledge, this is the first report to include an impressive illustration of nearly symmetric motor cortical involvement of encephalitis on brain MRI. Case presentation: A 51 year old immunocompromized man developed a high-grade pure motor flaccid tetraparesis over few days. Based on clinical presentation, critical illness polyneuromyopathy was suspected. However, brain MRI revealed symmetrical hyperintensities strictly limited to the subcortical precentral gyrus. An encephalitis, possibly due to CMV infection, turned out to be the most likely cause. Conclusion: While recognition of basic clinical patterns is indispensable in neurological reasoning, awareness of central conditions mimicking peripheral nervous disease may be crucial to detect unsuspected, potentially treatable conditions. KW - tetraparesis KW - motor cortex KW - CMV KW - encephalitis KW - case report Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-157576 VL - 17 IS - 31 ER - TY - JOUR A1 - Wurmb, Thomas Erik A1 - Schlereth, Stefan A1 - Kredel, Markus A1 - Muellenbach, Ralf M. A1 - Wunder, Christian A1 - Brederlau, Jörg A1 - Roewer, Norbert A1 - Kenn, Werner A1 - Kunze, Ekkehard T1 - Routine Follow-Up Cranial Computed Tomography for Deeply Sedated, Intubated, and Ventilated Multiple Trauma Patients with Suspected Severe Head Injury JF - BioMed Research International N2 - Background. Missed or delayed detection of progressive neuronal damage after traumatic brain injury (TBI) may have negative impact on the outcome. We investigated whether routine follow-up CT is beneficial in sedated and mechanically ventilated trauma patients. Methods. The study design is a retrospective chart review. A routine follow-up cCT was performed 6 hours after the admission scan. We defined 2 groups of patients, group I: patients with equal or recurrent pathologies and group II: patients with new findings or progression of known pathologies. Results. A progression of intracranial injury was found in 63 patients (42%) and 18 patients (12%) had new findings in cCT 2 (group II). In group II a change in therapy was found in 44 out of 81 patients (54%). 55 patients with progression or new findings on the second cCT had no clinical signs of neurological deterioration. Of those 24 patients (44%) had therapeutic consequences due to the results of the follow-up cCT. Conclusion. We found new diagnosis or progression of intracranial pathology in 54% of the patients. In 54% of patients with new findings and progression of pathology, therapy was changed due to the results of follow-up cCT. In trauma patients who are sedated and ventilated for different reasons a routine follow-up CT is beneficial. KW - Computertomographie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-120084 IS - 361949 ER - TY - JOUR A1 - Woźnicki, Piotr A1 - Laqua, Fabian Christopher A1 - Messmer, Katharina A1 - Kunz, Wolfgang Gerhard A1 - Stief, Christian A1 - Nörenberg, Dominik A1 - Schreier, Andrea A1 - Wójcik, Jan A1 - Ruebenthaler, Johannes A1 - Ingrisch, Michael A1 - Ricke, Jens A1 - Buchner, Alexander A1 - Schulz, Gerald Bastian A1 - Gresser, Eva T1 - Radiomics for the prediction of overall survival in patients with bladder cancer prior to radical cystectomy JF - Cancers N2 - (1) Background: To evaluate radiomics features as well as a combined model with clinical parameters for predicting overall survival in patients with bladder cancer (BCa). (2) Methods: This retrospective study included 301 BCa patients who received radical cystectomy (RC) and pelvic lymphadenectomy. Radiomics features were extracted from the regions of the primary tumor and pelvic lymph nodes as well as the peritumoral regions in preoperative CT scans. Cross-validation was performed in the training cohort, and a Cox regression model with an elastic net penalty was trained using radiomics features and clinical parameters. The models were evaluated with the time-dependent area under the ROC curve (AUC), Brier score and calibration curves. (3) Results: The median follow-up time was 56 months (95% CI: 48–74 months). In the follow-up period from 1 to 7 years after RC, radiomics models achieved comparable predictive performance to validated clinical parameters with an integrated AUC of 0.771 (95% CI: 0.657–0.869) compared to an integrated AUC of 0.761 (95% CI: 0.617–0.874) for the prediction of overall survival (p = 0.98). A combined clinical and radiomics model stratified patients into high-risk and low-risk groups with significantly different overall survival (p < 0.001). (4) Conclusions: Radiomics features based on preoperative CT scans have prognostic value in predicting overall survival before RC. Therefore, radiomics may guide early clinical decision-making. KW - bladder cancer KW - radical cystectomy KW - radiomics KW - outcome prediction Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-288098 SN - 2072-6694 VL - 14 IS - 18 ER - TY - JOUR A1 - Woznicki, Piotr A1 - Laqua, Fabian Christopher A1 - Al-Haj, Adam A1 - Bley, Thorsten A1 - Baeßler, Bettina T1 - Addressing challenges in radiomics research: systematic review and repository of open-access cancer imaging datasets JF - Insights into Imaging N2 - Objectives Open-access cancer imaging datasets have become integral for evaluating novel AI approaches in radiology. However, their use in quantitative analysis with radiomics features presents unique challenges, such as incomplete documentation, low visibility, non-uniform data formats, data inhomogeneity, and complex preprocessing. These issues may cause problems with reproducibility and standardization in radiomics studies. Methods We systematically reviewed imaging datasets with public copyright licenses, published up to March 2023 across four large online cancer imaging archives. We included only datasets with tomographic images (CT, MRI, or PET), segmentations, and clinical annotations, specifically identifying those suitable for radiomics research. Reproducible preprocessing and feature extraction were performed for each dataset to enable their easy reuse. Results We discovered 29 datasets with corresponding segmentations and labels in the form of health outcomes, tumor pathology, staging, imaging-based scores, genetic markers, or repeated imaging. We compiled a repository encompassing 10,354 patients and 49,515 scans. Of the 29 datasets, 15 were licensed under Creative Commons licenses, allowing both non-commercial and commercial usage and redistribution, while others featured custom or restricted licenses. Studies spanned from the early 1990s to 2021, with the majority concluding after 2013. Seven different formats were used for the imaging data. Preprocessing and feature extraction were successfully performed for each dataset. Conclusion RadiomicsHub is a comprehensive public repository with radiomics features derived from a systematic review of public cancer imaging datasets. By converting all datasets to a standardized format and ensuring reproducible and traceable processing, RadiomicsHub addresses key reproducibility and standardization challenges in radiomics. Critical relevance statement This study critically addresses the challenges associated with locating, preprocessing, and extracting quantitative features from open-access datasets, to facilitate more robust and reliable evaluations of radiomics models. Key points - Through a systematic review, we identified 29 cancer imaging datasets suitable for radiomics research. - A public repository with collection overview and radiomics features, encompassing 10,354 patients and 49,515 scans, was compiled. - Most datasets can be shared, used, and built upon freely under a Creative Commons license. - All 29 identified datasets have been converted into a common format to enable reproducible radiomics feature extraction. KW - radiomics KW - radiology KW - cancer imaging KW - machine learning KW - reproducibility of results Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357936 SN - 1869-4101 VL - 14 ER - TY - JOUR A1 - Woznicki, Piotr A1 - Laqua, Fabian A1 - Bley, Thorsten A1 - Baeßler, Bettina T1 - AutoRadiomics: a framework for reproducible radiomics research JF - Frontiers in Radiology N2 - Purpose Machine learning based on radiomics features has seen huge success in a variety of clinical applications. However, the need for standardization and reproducibility has been increasingly recognized as a necessary step for future clinical translation. We developed a novel, intuitive open-source framework to facilitate all data analysis steps of a radiomics workflow in an easy and reproducible manner and evaluated it by reproducing classification results in eight available open-source datasets from different clinical entities. Methods The framework performs image preprocessing, feature extraction, feature selection, modeling, and model evaluation, and can automatically choose the optimal parameters for a given task. All analysis steps can be reproduced with a web application, which offers an interactive user interface and does not require programming skills. We evaluated our method in seven different clinical applications using eight public datasets: six datasets from the recently published WORC database, and two prostate MRI datasets—Prostate MRI and Ultrasound With Pathology and Coordinates of Tracked Biopsy (Prostate-UCLA) and PROSTATEx. Results In the analyzed datasets, AutoRadiomics successfully created and optimized models using radiomics features. For WORC datasets, we achieved AUCs ranging from 0.56 for lung melanoma metastases detection to 0.93 for liposarcoma detection and thereby managed to replicate the previously reported results. No significant overfitting between training and test sets was observed. For the prostate cancer detection task, results were better in the PROSTATEx dataset (AUC = 0.73 for prostate and 0.72 for lesion mask) than in the Prostate-UCLA dataset (AUC 0.61 for prostate and 0.65 for lesion mask), with external validation results varying from AUC = 0.51 to AUC = 0.77. Conclusion AutoRadiomics is a robust tool for radiomic studies, which can be used as a comprehensive solution, one of the analysis steps, or an exploratory tool. Its wide applicability was confirmed by the results obtained in the diverse analyzed datasets. The framework, as well as code for this analysis, are publicly available under https://github.com/pwoznicki/AutoRadiomics. KW - radiomics KW - radiology KW - machine learning KW - reproducibility KW - workflow KW - image analysis Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-284813 SN - 2673-8740 VL - 2 ER - TY - THES A1 - Wirth, Clemens T1 - Klinische Wertigkeit der funktionellen Magnetresonanzurographie bei Kindern T1 - Value of semi-automated functional MR-Urography in clincal routine N2 - Die vorliegende retrospektive Arbeit zeigt die Einsatzmöglichkeiten der funktionellen Magnetresonanzurographie bei Kindern auf. Mit Hilfe der verwendeten Software lassen sich die funktionellen Aspekte der Untersuchung wenig zeitintensiv bearbeiten und die Ergebnisse anschaulich und verständlich darstellen. Die Beurteilung der funktionellen Ergebnisse erlaubt aus der Zusammenschau von errechneten definierten metrischen Daten der Untersuchung und der Kurvenanalyse eine Aussage zur seitengetrennten Nierenfunktion. Diese korreliert gut mit dem klinischen Ergebnis und der MAG 3 Szintigraphie als Standardverfahren. Als Funktionsparameter zur Unterscheidung zwischen normal funktionierender und dekompensierter obstruierter Nierenuretereinheit dient in erster Linie die renale Transitzeit des Kontrastmittels RTT. Durch Einführung einer Pseudonativsequenz konnten im Patientenkollektiv Untersuchungen der Auswertung zugeführt werden, die primär nicht auszuwerten waren. Eine Korrelation der errechneten Patlakzahl mit der geschätzten glomulären Filtrationsrate ließ sich in unserem Kollektiv nicht nachweisen. Insgesamt ist das Verfahren im klinischen Alltag weiter zu evaluieren, Prospektive Studien sollten eine eventuelle Überlegenheit dieser strahlenfreien Methode gegenüber der Szintigraphie als zentrale Fragestellung überprüfen. N2 - Retrospective functional assessment of MRU examinations between 2004 and 2011. Calculated functional parameters and curves were interpreted as normal (group 1), equivocal (group 2) or obstructed (group 3), followed by comparison with clinical outcome (SOR) and, if available, MAG 3 scintigraphy. CHOP-fMRU is a valuable tool to assess functional parameters in fMRU. CTT and RTT can help to differenciate between obstructed and normal KUU. Further prospective studies should evaluate the performance of fMRU compared to scintigraphy in children, in order to appraise the additional functional value of fMRU beyond morphological information. KW - Funktionelle NMR-Tomographie KW - Kinderradiologie KW - MR-Urography Pediatric Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-72593 ER - TY - JOUR A1 - Williams, Tatjana A1 - Machann, Wolfram A1 - Kühler, Leif A1 - Hamm, Henning A1 - Müller-Höcker, Josef A1 - Zimmer, Michael A1 - Ertl, Georg A1 - Ritter, Oliver A1 - Beer, Meinrad A1 - Schönberger, Jost T1 - Novel desmoplakin mutation: juvenile biventricular cardiomyopathy with left ventricular non-compaction and acantholytic palmoplantar keratoderma JF - Clinical Research in Cardiology N2 - Two sons of a consanguineous marriage developed biventricular cardiomyopathy. One boy died of severe heart failure at the age of 6 years, the other was transplanted because of severe heart failure at the age of 10 years. In addition, focal palmoplantar keratoderma and woolly hair were apparent in both boys. As similar phenotypes have been described in Naxos disease and Carvajal syndrome, respectively, the genes for plakoglobin (JUP) and desmoplakin (DSP) were screened for mutations using direct genomic sequencing. A novel homozygous 2 bp deletion was identified in an alternatively spliced region of DSP. The deletion 5208_5209delAG led to a frameshift downstream of amino acid 1,736 with a premature truncation of the predominant cardiac isoform DSP-1. This novel homozygous truncating mutation in the isoform-1 specific region of the DSP C-terminus caused Carvajal syndrome comprising severe early-onset heart failure with features of non-compaction cardiomyopathy, woolly hair and an acantholytic form of palmoplantar keratoderma in our patient. Congenital hair abnormality and manifestation of the cutaneous phenotype in toddler age can help to identify children at risk for cardiac death. KW - Desmoplakin KW - Juvenile biventricular cardiomyopathy KW - Palmoplantar keratoderma Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-141198 VL - 100 IS - 12 ER - TY - THES A1 - Wesemeier, Carmen Gudrun T1 - Eisenpartikelverstärkte Magnetresonanztomographie bei der Experimentellen-Autoimmun-Neuritis(EAN) T1 - Magnetic resonance imaging with Superparamagnetic iron oxide particels by experimental autoimmune neuritis N2 - In diesem experimentellen Ansatz ist es gelungen, durch Einsatz von eisenhaltigen Kontrastmittel die MRT-Spezifität bei peripheren autoimmunen Nervenentzündungen deutlich zu erhöhen. Es ist gelungen in vivo den zeitlichen Verlauf der Monozyten/Makropahgeninfiltration bei entzündliche Autoimmunerkrankungen des Peripheren Nervensystems zu demonstrieren. N2 - SPIO-enhanced MRI provides a novel in vivo tool to assess the timing of macrophage entry into target tissues during an immunopathologic attack and holds promise to monitor immunotherapeutic interventions. KW - Experimentelle allergische Neuritis KW - NMR-Tomographie KW - Peripheres Nervensystem KW - Makrophage KW - SPIO-Partikel KW - peripheral nervous system KW - superparamagnetic iron oxide particles KW - magnetic resonance imaging Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-24626 ER - TY - THES A1 - Werner, Alexander T1 - Vergleich verschiedener Kontrastmittelkonzentrationen für die Computertomographie des Abdomens T1 - Comparison of different iodine concentrations for multidetector row CT of the upper abdomen N2 - Das Ziel der vorliegenden Arbeit war es, die Auswirkungen von drei unter-schiedlichen Jodkonzentrationen eines Kontrastmittels sowohl bei gleicher In-jektionsgeschwindigkeit als auch bei gleicher Jodmenge/Zeiteinheit auf den Dichteanstieg in Leber, Pankreas, Milz und Aorta bei der Mehrzeilendetektor-Spiral-CT zu untersuchen. In die prospektive Studie wurden 120 Patienten im Alter von 706 Jahren mit einer bekannten oder vermuteten Leberraumforderung aufgenommen, die sich einer triphasischen Mehrzeilendetektor-Spiral-CT-Untersuchung des Abdomens unterzogen. Als Kontrastmittel wurde das nicht-ionische Iopromid verwendet. Die Patienten wurden in sechs gleich große Gruppen eingeteilt. Die Gruppen waren wie folgt charakterisiert: Gruppe I: 150 ml (KM-Volumen), 240 mg/ml (Jodkonzentration) bei 4 ml/s (Injektionsgeschwindigkeit); Gruppe II: 120 ml, 300 mg/ml bei 4 ml/s; Gruppe III: 100 ml, 370 mg/ml bei 4 ml/s; Gruppe IV: 150 ml, 240 mg/ml bei 5 ml/s; Gruppe V: 120 ml, 300 mg/ml, 60 ml bei 6 ml/s, 60 ml bei 3 ml/s; Gruppe VI: 100 ml, 370 mg/ml bei 3,3 ml/s. Die Gesamtjodmenge war stets konstant und betrug 36 g. Der Dichteanstieg wurde in der Leber (kra-nial, Mitte, kaudal, linker Leberlappen), im Pankreas, in der Milz und in der Aorta (kranial und kaudal) in der nativen, arteriellen, portal-venösen und Paren-chymphase mit Hilfe einer ROI gemessen. Für den statistischen Vergleich der Gruppen wurden der Kruskal-Wallis-Test (Vergleich von mehr als zwei Grup-pen) und der Mann-Whitney-Test (Vergleich von zwei Gruppen) verwendet. Beim Vergleich der Gruppen, die das Kontrastmittel mit gleicher Injektionsge-schwindigkeit erhielten (Gruppe I-III), zeigte sich ein signifikant höheres En-hancement (p=0,02) des Pankreas in der arteriellen Phase bei Gabe des Kon-trastmittels mit einer Konzentration von 370 mg/ml (7420 HE) im Vergleich zur Gabe von Kontrastmitteln mit Konzentrationen von 240 mg/ml (5815 HE) und 300 mg/ml (6212 HE). Sowohl beim Vergleich der Gruppen, die das Kon-trastmittel mit gleicher Jodmenge/Zeiteinheit erhielten (Gruppe II, IV und VI) als auch beim Vergleich aller Gruppen zeigten sich keine signifikanten Grup-penunterschiede hinsichtlich des Dichteanstiegs in den untersuchten Organen. Mit Hilfe der vorliegenden Arbeit konnte auf der einen Seite gezeigt werden, dass bei konstanter Jodgesamtmenge und konstanter Injektionsgeschwindig-keit das Kontrastmittel mit der höheren Jodkonzentration das Enhancement des Pankreas in der arteriellen Phase signifikant verbessert. Auf der anderen Seite konnte gezeigt werden, dass bei konstanter Jodgesamtmenge und konstanter Jodmenge/Zeiteinheit keine signifikanten Unterschiede zwischen den Jodkon-zentrationen hinsichtlich des Enhancements von Oberbauchorganen bestehen. N2 - The effect of different iodine concentrations at either constant injection or iodine administration rates but constant total iodine load on contrast enhancement of liver, pancreas and spleen by multidetector row CT was investigated. 120 consecutive patients (70±6 years) underwent triphasic liver CT at a 4-channel multidetector row CT using the non-ionic contrast medium iopromide. Patients were divided into six equal groups: I:150ml, 240mg/ml@4ml/s; II:120ml, 300mg/ml@4ml/s; III:97.3ml, 370mg/ml@4ml/s; IV:150ml, 240mg/ml@5ml/s; V:120ml, 300mg/ml, 60ml@6ml/s, 60ml@3ml/s; VI:97.3ml, 370mg/ml@3.3ml/s. ROIs were measured in the liver, the pancreas, and the spleen in unenhanced, arterial, portal venous, and equilibrium phase. At a constant injection rate of 4ml/s, pancreatic enhancement over baseline only in the arterial phase was significantly higher at 370mg/ml (58±15HU vs. 59±18HU vs. 74±20HU for group I-III, respectively (p<0.02)). Comparison of different iodine concentrations at constant iodine administration rate (group II, IV, VI) and of all six protocols revealed no significant differences at either phase. At a constant iodine load and constant injection rates, the high-iodinated contrast agent iopromide at 370 mg/ml improves pancreatic enhancement in the arterial phase. At constant iodine load and constant iodine administration rates, there is no significant effect of different iodine concentrations. KW - Computertomographie KW - Spiral-CT KW - Abdomen KW - Bauchspeicheldrüsentumor KW - Lebertumor KW - Nichtionisches Kontrastmittel KW - Liver CT KW - Pancreas CT KW - contrast media Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-24425 ER - TY - JOUR A1 - Weng, Andreas M. A1 - Köstler, Herbert A1 - Bley, Thorsten A. A1 - Ritter, Christian O. T1 - Effect of short-term smoking & L-arginine on coronary endothelial function assessed by cardiac magnetic resonance cold pressor testing: a pilot study JF - BMC Cardiovascular Disorders N2 - Background The effect of smoking on coronary vasomotion has been investigated in the past with various imaging techniques in both short- and long-term smokers. Additionally, coronary vasomotion has been shown to be normalized in long-term smokers by L-Arginine acting as a substrate for NO synthase, revealing the coronary endothelium as the major site of abnormal vasomotor response. Aim of the prospective cohort study was to investigate coronary vasomotion of young healthy short-term smokers via magnetic resonance cold pressor test with and without the administration of L-Arginine and compare obtained results with the ones from nonsmokers. Methods Myocardial blood flow (MBF) was quantified with first-pass perfusion MRI on a 1.5 T scanner in healthy short-term smokers (N = 10, age: 25.0 ± 2.8 years, 5.0 ± 2.9 pack years) and nonsmokers (N = 10, age: 34.3 ± 13.6) both at rest and during cold pressor test (CPT). Smokers underwent an additional examination after administration of L-Arginine within a median of 7 days of the naïve examination. Results MBF at rest turned out to be 0.77 ± 0.30 (smokers with no L-Arginine; mean ± standard deviation), 0.66 ± 0.21 (smokers L-Arginine) and 0.84 ± 0.08 (nonsmokers). Values under CPT were 1.21 ± 0.42 (smokers no L-Arginine), 1.09 ± 0.35 (smokers L-Arginine) and 1.63 ± 0.33 (nonsmokers). In all groups, MBF was significantly increased under CPT compared to the corresponding rest examination (p < 0.05 in all cases). Additionally, MBF under CPT was significantly different between the smokers and the nonsmokers (p = 0.002). MBF at rest was significantly different between the smokers when L-Arginine was given and the nonsmokers (p = 0.035). Conclusion Short-term smokers showed a reduced response to cold both with and without the administration of L-Arginine. However, absolute MBF values under CPT were lower compared to nonsmokers independently of L-Arginine administration. KW - MRI KW - myocardial perfusion KW - cold pressor test KW - endothelium KW - L-arginine KW - smoking Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260559 VL - 21 ER - TY - JOUR A1 - Weng, Andreas M. A1 - Heidenreich, Julius F. A1 - Metz, Corona A1 - Veldhoen, Simon A1 - Bley, Thorsten A. A1 - Wech, Tobias T1 - Deep learning-based segmentation of the lung in MR-images acquired by a stack-of-spirals trajectory at ultra-short echo-times JF - BMC Medical Imaging N2 - Background Functional lung MRI techniques are usually associated with time-consuming post-processing, where manual lung segmentation represents the most cumbersome part. The aim of this study was to investigate whether deep learning-based segmentation of lung images which were scanned by a fast UTE sequence exploiting the stack-of-spirals trajectory can provide sufficiently good accuracy for the calculation of functional parameters. Methods In this study, lung images were acquired in 20 patients suffering from cystic fibrosis (CF) and 33 healthy volunteers, by a fast UTE sequence with a stack-of-spirals trajectory and a minimum echo-time of 0.05 ms. A convolutional neural network was then trained for semantic lung segmentation using 17,713 2D coronal slices, each paired with a label obtained from manual segmentation. Subsequently, the network was applied to 4920 independent 2D test images and results were compared to a manual segmentation using the Sørensen–Dice similarity coefficient (DSC) and the Hausdorff distance (HD). Obtained lung volumes and fractional ventilation values calculated from both segmentations were compared using Pearson’s correlation coefficient and Bland Altman analysis. To investigate generalizability to patients outside the CF collective, in particular to those exhibiting larger consolidations inside the lung, the network was additionally applied to UTE images from four patients with pneumonia and one with lung cancer. Results The overall DSC for lung tissue was 0.967 ± 0.076 (mean ± standard deviation) and HD was 4.1 ± 4.4 mm. Lung volumes derived from manual and deep learning based segmentations as well as values for fractional ventilation exhibited a high overall correlation (Pearson’s correlation coefficent = 0.99 and 1.00). For the additional cohort with unseen pathologies / consolidations, mean DSC was 0.930 ± 0.083, HD = 12.9 ± 16.2 mm and the mean difference in lung volume was 0.032 ± 0.048 L. Conclusions Deep learning-based image segmentation in stack-of-spirals based lung MRI allows for accurate estimation of lung volumes and fractional ventilation values and promises to replace the time-consuming step of manual image segmentation in the future. KW - MRI KW - lung KW - deep learning KW - image segmentation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260520 VL - 21 ER - TY - THES A1 - Welsch, Stefan T1 - Die Rolle des iFlow-Algortithmus im Rahmen der endovaskulären Therapie von symptomatischen Nierenarterienstenosen T1 - The role of the iFlow-algorithm within the endovascular treatment of symptomatic renal artery stenosis N2 - Das Ziel dieser Arbeit war herauszufinden, ob der iFlow-Algorithmus als zusätzlicher Parameter zu Evaluierung des technischen Erfolgs einer Revaskularisation einer Nierenarterienstenose eingesetzt werden kann. Hierfür haben wir die „mean time to peak“ in Sekunden in den farbcodierten Bildern gemessen, um den Effekt einer Stentimplantation auf den Blutfluss zu eruieren. Im Verlauf haben wir dann getestet, ob unsere Ergebnisse den klinischen Verlauf unserer Patienten wiederspiegeln, um feststellen zu können, ob die syngo iFlow-Software den Erfolg der endovaskulären Therapie voraussagen kann. N2 - The goal of this Dissertation was to evaluate the application of the iFlow-Algorithm as a supplementary tool to predict the technical success of renal artery revascularization. To accomplish this, we measured the mean time to peak in color coded DSA images in seconds to evaluate the effect of the endovascular stent implantation on the arterial blood flow. We then tested, if our findings also represent the clinical progress of our patients to see if the syngo iFlow-Software can predict a successful endovascular treatment. KW - endovascular KW - Nierenarterie KW - renal artery KW - Bluthochdruck KW - high blood pressure Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-223324 ER - TY - THES A1 - Weiß, Sandra Elisabeth T1 - Erstmalige Sauerstoff-basierte MR-Lungenfunktionsanalyse im Schulkindesalter – lassen sich Veränderungen der Ventilation bei ehemals frühgeborenen Kindern nachweisen? T1 - First oxygen-enhanced functional MRI of the lung in school aged children - can changes in the ventilation of premature infants be proven? N2 - Oxygen-enhanced functional low-field MRI of the lung in formerly very low birth weight infants with and without bronchopulmonary dysplasia (BPD) Clemens Wirth1, Sandra Weiß1, Daniel Stäb1, Wolfgang Thomas2, Henning Neubauer1, Helge Hebestreit2, Herbert Köstler1, Dietbert Hahn1, Meinrad Beer1 1 Institute of Radiology, 2 Department of Pediatrics, University of Wuerzburg, Germany Purpose: To assess functional lung abnormalities in formerly very low birth weight infants (VLBW) with and without BPD compared with children born at term without lung pathology in an oxygen-enhanced open low-field MRI. Materials and methods: 40 children aged 7–12 years were included in this study. 10 children had BPD, 15 were VLBW without BPD (non-BPD) and 15 formerly term infants served as controls (CON). Sagittal T1-weighted single inversion multi-gradientecho sequences were acquired for both lungs at an open low-field MRI (Magnetom Open 0.2 Tesla, Siemens Medical Solutions, Erlangen, Germany). Acquisition was performed in 2 cycles: whilst breathing ambient air, then 100% oxygen via breathing mask. The mean relative change of the T1 relaxation time (ΔT1) between the two cycles was calculated after pixelwise subtraction of the parameter maps. ΔT1 of the different groups was compared statistically. Results: ΔT1 of the different groups was calculated as follows: CON 10.7 +/− 2.3%; Non-BPD 10.8 +/− 3.0%; BPD 9.2 +/− 3.1%. ΔT1 was significantly lower in the BPD group compared to both other groups (Mann–Whitney-U; p<0.05). There was no significant change of ΔT1 between the Non-BPD and the control group (p=0.93). Subanalysis of the lobes showed inhomogenieties of ΔT1 in the BPD group. Conclusion: Functional oxygen-enhanced MRI shows significant differences of ΔT1 in patients with BPD compared to children without BPD, reflecting probable long term functional sequelae of disturbed pulmonary vascular and alveolar development of the disease. N2 - Die T1-Relaxationszeiten der gesunden Kontrollgruppe (Reifgeborene) lag durchschnittlich bei 662 ± 55 ms bei Raumluft und 591 ± 48 ms bei reinem Sauerstoff, die relativen Differenzen bei 10,7 ± 2,3 %. Dies deckt sich mit in der Literatur angegebenen Werten. Die relative Differenz gibt Aufschluss über den Sauerstofftransfer im Blut: je mehr Sauerstoff gelöst im Blut vorliegt, desto niedriger wird der T1-Wert und desto höher die absolute Differenz. Bei der Gruppe der Frühgeborenen mit BPD (Bronchopulmonale Dysplasie) zeigte sich eine geringere relative Differenz (Mittelwert = 9,2 +/- 3,1%) im Vergleich zu dem Mittelwert der Frühgeborenen ohne BPD (10,8 +/- 3,0%) sowie der Reifgeborenen (10,7 +/-2,3%), was auf einen geringeren Sauerstofftransfer in der Lunge schließen lässt. Bei statistischer Auswertung der einzelnen Schichten zeigte sich lediglich in der medialen linken Schicht ein signifikanter Unterschied der relativen Differenz der T1-Werte. Die Differenz war in der Gruppe der Frühgeborenen mit BPD signifikant niedriger als in der Gruppe der Frühgeborenen ohne BPD bzw. der Kontrollgruppe. Bei den ausgewerteten T1-Karten konnten keine lokalen Auffälligkeiten festgestellt werden. Auch morphologisch ergaben sich keinerlei Auffälligkeiten. Es scheint ein globales Problem im Sauerstofftransfer vorzuliegen. Die Ergebnisse legen nahe, dass bei Kindern, die nach Geburt an einer schweren Form der BPD erkrankt sind, bis zumindest ins Schulkindesalter ein persistierend gestörter Sauerstofftransfer im Lungenparenchym gegeben ist. Diese funktionelle Einschränkung betrifft die gesamte Lunge, die höheren Abweichungen der Messergebnisse in einzelnen Lungenabschnitten bei den ehemaligen Frühgeborenen mit BPD legen eine höhere regionale Diversität nahe. Bei Frühgeborenen ohne chronische Lungenerkrankung sind in MRT-Messungen keine Unterschiede zu Reifgeborenen nachzuweisen. Es ist also anzunehmen, dass nicht allein durch die Frühgeburtlichkeit und das geringe Geburtsgewicht eine obstruktive Einschränkung in der Lungenfunktion als Langzeitfolge im Kindesalter weiter fort besteht, sondern der Faktor der BPD zusätzlich zu einem verminderten Gastransfer in der Lunge führt, welcher am ehesten durch eine verminderte Alveolarisierung und Vaskularisation in der Lunge bedingt ist. KW - MRT KW - BPD KW - Lungenfunktionsdiagnostik Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-143730 ER - TY - JOUR A1 - Weick, Stefan A1 - Breuer, Kathrin A1 - Richter, Anne A1 - Exner, Florian A1 - Ströhle, Serge-Peer A1 - Lutyj, Paul A1 - Tamihardja, Jörg A1 - Veldhoen, Simon A1 - Flentje, Michael A1 - Polat, Bülent T1 - Non-rigid image registration of 4D-MRI data for improved delineation of moving tumors JF - BMC Medical Imaging N2 - Background To increase the image quality of end-expiratory and end-inspiratory phases of retrospective respiratory self-gated 4D MRI data sets using non-rigid image registration for improved target delineation of moving tumors. Methods End-expiratory and end-inspiratory phases of volunteer and patient 4D MRI data sets are used as targets for non-rigid image registration of all other phases using two different registration schemes: In the first, all phases are registered directly (dir-Reg) while next neighbors are successively registered until the target is reached in the second (nn-Reg). Resulting data sets are quantitatively compared using diaphragm and tumor sharpness and the coefficient of variation of regions of interest in the lung, liver, and heart. Qualitative assessment of the patient data regarding noise level, tumor delineation, and overall image quality was performed by blinded reading based on a 4 point Likert scale. Results The median coefficient of variation was lower for both registration schemes compared to the target. Median dir-Reg coefficient of variation of all ROIs was 5.6% lower for expiration and 7.0% lower for inspiration compared with nn-Reg. Statistical significant differences between the two schemes were found in all comparisons. Median sharpness in inspiration is lower compared to expiration sharpness in all cases. Registered data sets were rated better compared to the targets in all categories. Over all categories, mean expiration scores were 2.92 +/- 0.18 for the target, 3.19 +/- 0.22 for nn-Reg and 3.56 +/- 0.14 for dir-Reg and mean inspiration scores 2.25 +/- 0.12 for the target, 2.72 +/- 215 0.04 for nn-Reg and 3.78 +/- 0.04 for dir-Reg. Conclusions In this work, end-expiratory and inspiratory phases of a 4D MRI data sets are used as targets for non-rigid image registration of all other phases. It is qualitatively and quantitatively shown that image quality of the targets can be significantly enhanced leading to improved target delineation of moving tumors. KW - 4D-MRI KW - Non-rigid image registration KW - Radiotherapy treatment planning KW - Respiratory induced tumor motion Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229271 VL - 20 ER - TY - JOUR A1 - Wech, Tobias A1 - Ankenbrand, Markus Johannes A1 - Bley, Thorsten Alexander A1 - Heidenreich, Julius Frederik T1 - A data-driven semantic segmentation model for direct cardiac functional analysis based on undersampled radial MR cine series JF - Magnetic Resonance in Medicine N2 - Purpose Image acquisition and subsequent manual analysis of cardiac cine MRI is time-consuming. The purpose of this study was to train and evaluate a 3D artificial neural network for semantic segmentation of radially undersampled cardiac MRI to accelerate both scan time and postprocessing. Methods A database of Cartesian short-axis MR images of the heart (148,500 images, 484 examinations) was assembled from an openly accessible database and radial undersampling was simulated. A 3D U-Net architecture was pretrained for segmentation of undersampled spatiotemporal cine MRI. Transfer learning was then performed using samples from a second database, comprising 108 non-Cartesian radial cine series of the midventricular myocardium to optimize the performance for authentic data. The performance was evaluated for different levels of undersampling by the Dice similarity coefficient (DSC) with respect to reference labels, as well as by deriving ventricular volumes and myocardial masses. Results Without transfer learning, the pretrained model performed moderately on true radial data [maximum number of projections tested, P = 196; DSC = 0.87 (left ventricle), DSC = 0.76 (myocardium), and DSC =0.64 (right ventricle)]. After transfer learning with authentic data, the predictions achieved human level even for high undersampling rates (P = 33, DSC = 0.95, 0.87, and 0.93) without significant difference compared with segmentations derived from fully sampled data. Conclusion A 3D U-Net architecture can be used for semantic segmentation of radially undersampled cine acquisitions, achieving a performance comparable with human experts in fully sampled data. This approach can jointly accelerate time-consuming cine image acquisition and cumbersome manual image analysis. KW - undersampling KW - cardiovascular magnetic resonance (CMR) KW - deep learning KW - radial KW - semantic segmentation Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-257616 VL - 87 IS - 2 ER - TY - JOUR A1 - Weber, J. A1 - Glutsch, V. A1 - Geissinger, E. A1 - Haug, L. A1 - Lock, J.F. A1 - Schneider, F. A1 - Kneitz, H. A1 - Goebeler, M. A1 - Schilling, B. A1 - Gesierich, A. T1 - Neoadjuvant immunotherapy with combined ipilimumab and nivolumab in patients with melanoma with primary or in transit disease JF - British Journal of Dermatology N2 - The introduction of new therapeutic agents has revolutionized the treatment of metastatic melanoma. The approval of adjuvant anti‐programmed death‐1 monotherapy with nivolumab or pembrolizumab, and dabrafenib plus trametinib has recently set a new landmark in the treatment of stage III melanoma. Now, clinical trials have shown that immune checkpoint blockade can be performed in a neoadjuvant setting, an approach established as a standard therapeutic approach for other tumour entities such as breast cancer. Recent studies suggest that a pathological response achieved by neoadjuvant immunotherapy is associated with long‐term tumour control and that short neoadjuvant application of checkpoint inhibitors may be superior to adjuvant therapy. Most recently, neoadjuvant ipilimumab plus nivolumab in stage III melanoma was reported. With two courses of dose‐optimized ipilimumab (1 mg kg−1) combined with nivolumab (3 mg kg−1), pathological responses were observed in 77% of patients, while only 20% of patients experienced grade 3 or 4 adverse events. However, the neoadjuvant trials employing combined immune checkpoint blockade conducted so far have excluded patients with in transit metastases, a common finding in stage III melanoma. Here we report four patients with in transit metastases or an advanced primary tumour who have been treated with neoadjuvant ipilimumab plus nivolumab according to the OpACIN‐neo trial scheme (arm B). All patients achieved radiological disease control and a pathological response. None of the patients has relapsed so far. KW - Immunotherapy Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-213520 VL - 183 IS - 3 ER - TY - THES A1 - Völker, Nina T1 - Vakuumstanzbiopsie nonpalpabler mammographischer Befunde mit manueller Führung T1 - Manually guided vacuum-assisted biopsy of nonpalpable mammographic findings N2 - Zur Abklärung malignitätsverdächtiger Befunde in der Brust benötigt man eine effektive minimal-invasive Methode. Diese retrospektive Studie evaluiert die Wertigkeit der Vakuumstanzbiopsie mit manueller Führung. Es zeigt sich, dass hier eine unkomplizierte und ausreichende Gewinnung von Gewebe und somit eine zuverlässige Einschätzung von mammographischen Auffälligkeiten möglich ist. N2 - The clarification of suspect mammographic findings requires an efficient minimal-invasive method. In this dissertation the manually guided vacuum-assisted breast biopsy is evaluated. It proves to be an uncomplicated and sufficient tissue extraction technique allowing a reliable clarification of mammographic findings. KW - Biopsie KW - Mammographie KW - Vakuumstanzbiopsie KW - vacuum-assisted biopsy Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-24926 ER - TY - JOUR A1 - Vogt, Marius A1 - Girschick, Hermann A1 - Schweitzer, Tilmann A1 - Benoit, Clemens A1 - Holl-Wieden, Annette A1 - Seefried, Lothar A1 - Jakob, Franz A1 - Hofmann, Christine T1 - Pediatric hypophosphatasia: lessons learned from a retrospective single-center chart review of 50 children JF - Orphanet Journal of Rare Diseases N2 - Background Hypophosphatasia (HPP) is a rare, inherited metabolic disorder caused by loss-of-function mutations in the ALPL gene that encodes the tissue-nonspecific alkaline phosphatase TNAP (ORPHA 436). Its clinical presentation is highly heterogeneous with a remarkably wide-ranging severity. HPP affects patients of all ages. In children HPP-related musculoskeletal symptoms may mimic rheumatologic conditions and diagnosis is often difficult and delayed. To improve the understanding of HPP in children and in order to shorten the diagnostic time span in the future we studied the natural history of the disease in our large cohort of pediatric patients. This single centre retrospective chart review included longitudinal data from 50 patients with HPP diagnosed and followed at the University Children's Hospital Wuerzburg, Germany over the last 25 years. Results The cohort comprises 4 (8%) perinatal, 17 (34%) infantile and 29 (58%) childhood onset HPP patients. Two patients were deceased at the time of data collection. Diagnosis was based on available characteristic clinical symptoms (in 88%), low alkaline phosphatase (AP) activity (in 96%), accumulating substrates of AP (in 58%) and X-ray findings (in 48%). Genetic analysis was performed in 48 patients (31 compound heterozygous, 15 heterozygous, 2 homozygous mutations per patient), allowing investigations on genotype-phenotype correlations. Based on anamnestic data, median age at first clinical symptoms was 3.5 months (min. 0, max. 107), while median time to diagnosis was 13 months (min. 0, max. 103). Common symptoms included: impairment of motor skills (78%), impairment of mineralization (72%), premature loss of teeth (64%), musculoskeletal pain and craniosynostosis (each 64%) and failure to thrive (62%). Up to now 20 patients started medical treatment with Asfotase alfa. Conclusions Reported findings support the clinical perception of HPP being a chronic multi-systemic disease with often delayed diagnosis. Our natural history information provides detailed insights into the prevalence of different symptoms, which can help to improve and shorten diagnostics and thereby lead to an optimised medical care, especially with promising therapeutic options such as enzyme-replacement-therapy with Asfotase alfa in mind. KW - hypophosphatasia KW - alkaline phosphatase KW - asfotase alfa KW - rare bone disease KW - osteomalacia KW - rickets Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230505 VL - 15 ER - TY - THES A1 - Vogelsang, Carsten T1 - Optimierung der bolusgetriggerten Spiral-Computertomographie der Leber und Vergleich zum empirischen Bolustiming T1 - Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT N2 - In der vorliegenden Arbeit wurde eine Eignung des Bolus Tracking beim 4-Phasen Spiral CT insbesondere zur Ermittlung einer optimalen Frühphase des hepatobiliären Systems nachgewiesen. Die optimale Frühphase wurde definiert bei 20%-30% Leberenhancement im Vergleich zur portalvenösen Phase. 250 Untersuchungen des Abdomens wurden an einem Spiral CT mit identischem Tischvorschub und Schichtdicke durchgeführt, wobei 200 Patienten mit Bolus Tracking und 50 Patienten mit Standardverfahren untersucht wurden. Die Startverzögerung der Frühphase beim Standardverfahren betrug 25 Sekunden und bei allen 250 Untersuchungen wurde für die portalvenöse Phase ein Delay von 60 Sekunden nach Start der arteriellen Phase gewählt. Zu Beginn der Studie wurden 150 Untersuchungen mit Bolus Tracking untersucht, dabei wurden die Patienten randomisiert auf 6 verschiedene Protokolle mit Schwellenwerten von 50 HE, 75 HE und 100 HE bei Startverzögerungen von 5 und 10 Sekunden aufgeteilt. Es ergab sich ein signifikanter Vorteil für das Protokoll mit einem Schwellenwert von 75 HE und 10 Sekunden Startverzögerung. Weitere 50 Untersuchungen bei einem Schwellenwert von 75 HE und einer Startverzögerung von 10 Sekunden wurden mit 50 Patienten mit Standardverfahren verglichen. Hier zeigte sich kein signifikanter Unterschied Bolus Tracking versus Standardverfahren bei jedoch einem tendenziellen Vorteil des Bolus Tracking. N2 - The aim of this study was to optimize bolus tracking for timing of the arterial phase of biphasic helical liver CT and to compare optimized bolus tracking to a standard delay. One hundred fifty patients were examined with six protocols: 5-or 10-s delay after triggering at a threshold of 50 or 75 or 100 HU enhancement in the aorta at the origin of the celiac arteries after injection of 120 ml contrast material at 3 ml/s. Optimal arterial enhancement was defined as 20-30% of the hepatic enhancement in portal venous phase. Another 50 patients were examined with the optimized protocol and compared to 50 gender- and age-matched patients who underwent a 25-s standard delay. A 10-s delay after the 75-HU threshold resulted in the most patients with an optimal arterial phase (p< 0,01). Thirty-one of 75 patients examined with this protocol showed optimal early liver enhancement. Bolus tracking compared with standard delay revealed only a trend for a difference (p=0,07). The outcome of automatic bolus tracking differs depending on the protocol used;however, optimal arterial phase imaging was seen in only 41% of patients, indicating only a trend for superior timing compared with a standard delay. KW - Spiral-Computertomographie KW - Leber KW - Bolustriggerung KW - Frühphase KW - Computed tomography KW - liver KW - contrast media KW - bolus tracking Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-18527 ER - TY - JOUR A1 - Vogel, Patrick A1 - Markert, Jonathan A1 - Rückert, Martin A. A1 - Herz, Stefan A1 - Keßler, Benedikt A1 - Dremel, Kilian A1 - Althoff, Daniel A1 - Weber, Matthias A1 - Buzug, Thorsten M. A1 - Bley, Thorsten A. A1 - Kullmann, Walter H. A1 - Hanke, Randolf A1 - Zabler, Simon A1 - Behr, Volker C. T1 - Magnetic Particle Imaging meets computed tomography: first simultaneous imaging JF - Scientific Reports N2 - Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented. KW - Applied physics KW - Biomedical engineering KW - Imaging techniques Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-202501 VL - 9 ER - TY - JOUR A1 - Vogel, P. A1 - Rückert, M. A. A1 - Greiner, C. A1 - Günther, J. A1 - Reichl, T. A1 - Kampf, T. A1 - Bley, T. A. A1 - Behr, V. C. A1 - Herz, S. T1 - iMPI: portable human-sized magnetic particle imaging scanner for real-time endovascular interventions JF - Scientific Reports N2 - Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model. KW - biomedical engineering KW - electrical and electronic engineering KW - imaging KW - three-dimensional imaging Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357794 VL - 13 ER - TY - THES A1 - Viehrig, Marén T1 - Quantitative Analyse des Energiestoffwechsels bei Patienten mit Vorderwandinfarkt und Aortenklappenersatz mittels 31P-Magnetresonanzspektroskopie T1 - Quantitative analysis of energy metabolism in patients with anterior myocardial infarction and aortal valve prothesis by 31P-magnetic resonance spectroscopy N2 - Ziel der vorliegenden Arbeit war a)die Untersuchung eines Patientenkollektives vor und drei Monate sowie ein Jahr nach Aortenklappenersatz, d.h. von Patienten, bei denen eine globale Linksherzerkrankung vorliegt. Es sollte herausgefunden werden, ob sich aus dem Energiestatus vor der Operation auf deren Erfolg rückschließen läßt und man somit Empfehlungen für den Zeit-punkt des Klappenersatzes aus einer 31P - MRS ableiten kann. Damit sollte erstmals eine quantitative Beurteilung des Metabolismus bei Herzklappenvitien sowie eine Korrelation der so ermittelten Parameter mit dem klinischen Zustand der Patienten vor und nach der Operation versucht werden. Es wurden 21 Patienten mit Aortenklappenvitien untersucht, für 14 davon lagen auch die Werte der ersten Kontrolle nach einem Vierteljahr und für 5 die Werte nach einem Jahr vor. Aortenklappenvitien führen zu einer globalen Herzerkrankung (hier überwiegend linksventrikuläre Hypertro-phie bei Klappenstenose). Dies vereinfacht die spektroskopische Unter-suchung. Es wurde eine quantitative Untersuchung des Energiestoff-wechsels des Herzens dieser Patienten durchgeführt. Dabei ergaben sich Hinweise darauf, daß die Patienten um so mehr von der Operation profi-tieren, je schlechter ihre präoperativen Werte waren. Es konnte jedoch kein Parameter als Kriterium für den besten Operationszeitpunkt etabliert werden. Hierzu ist die Beurteilung der Nachkontrollen sowie generell ei-nes größeren Patientenkollektives abzuwarten. b) Das zweite Patientenkollektiv bildeten Patienten, die einen Herzinfarkt erlitten hatten, d.h. mit einer regionalen Herzschädigung. Sie wurden vor und ein halbes Jahr nach Therapie durch PTCA oder Bypass-Operation untersucht. Ziel war die Beurteilung der Untersuchung auf ihre Zuverlässigkeit bezüglich der Unterscheidung von vitalem und avi-talem Herzmuskel im Infarktbereich. Diese ist wichtig für die Entschei-dung, ob die Patienten von einer Operation profitieren können oder nicht. In dieser Studie wurden 50 Patienten untersucht, absolut eine geringe Anzahl, verglichen mit den Größen der bislang publizierten Studien je-doch eine sehr große Studie. Der Vergleich zwischen infarzierten und nichtinfarzierten Arealen mittels MRS sowie die quantitative Beurteilung metabolischer Schäden bei einem Infarkt wurde hier erstmalig durchge-führt. Dabei zeigte sich eine signifikante Unterscheidung der Absolutwerte von Patienten und Probanden. Ein Kriterium für die Unterscheidung zwi-schem avitalem und hibernating oder stunned myocardium konnte hier noch nicht gefunden werden, offensichtlich reicht hierfür das einfache Verhältnis PCr/g-ATP nicht aus. Eventuell kann eine Kombination von Pa-rametern gefunden werden. Im Vergleich der eigenen Ergebnisse mit de-nen des Goldstandards, d.h. den Dobutamin-Streß-MRI Untersuchungen wies die Spektroskopie eine Sensitivität von 47,1% gegenüber dem Gold-standard auf. Dies liegt unter anderem daran, daß bei der MRI-Untersuchung einzelne Segmente beurteilt werden konnten, während die Beurteilung einer regionalen Herzerkrankung aufgrund der geringen Ort-sauflösung der Spektroskopie noch Schwierigkeiten bereitet. Sollte es in Zukunft möglich sein, SLOOP-Spektren aus einzelnen Herzsegmenten zu erhalten, könnte sich dieser Wert verbessern. c) Die gemessenen 31P-Spektren wurden mit 3 verschiedenen Auswer-tungsprogrammen, LUISE, AMARES und SLOOP untersucht. Die so gewonnenen Ergebnisse sollten verglichen und die Verfahren hinsicht-lich Leistungsfähigkeit/Genauigkeit, Durchführbarkeit und Nutzen ver-glichen werden. Im Vergleich der drei Auswertungsverfahren stellte sich Folgendes her-aus: Kriterium LUISE AMARES SLOOP einfache Handha-bung/Erlernbarkeit ++ +++ + regionale Herzbeurtei-lung ++ ++ + Vergleichbarkeit der Ergebnisse + ++ +++ geringer Zeitaufwand ++ +++ + Abbildung 6﷓1: Vergleich der 3 Auswertungsverfahren Das während der Laufzeit dieser Arbeit entwickelte SLOOP-Verfahren brachte den Durchbruch zur Absolutquantifizierung. Damit wird eine Vergleichbarkeit der von zu verschiedenen Zeitpunkten, von verschiedenen Patienten und unter-schiedlichenn Arbeitsgruppen gewonnenen Daten ohne Korrekturfaktoren mög-lich. Die Güte der damit ermittelten Werte zeigt sich unter anderem darin, daß nur mit den SLOOP-Werten signifikante Ergebnisse im Vergleich mit den MRI-Daten erzielt werden konnten. Dies liegt an der Tatsache, daß bei den anderen Verfahren eine zu große Streuung der Werte auftritt. Im Vergleich der drei Auswertungsverfahren liefert aber derzeit AMARES am schnellsten und einfachsten verwertbare Daten. N2 - The purpose of this work was a)to investigate a collective of patients before and 3 months after implantation of a new aortal valve that is of patients with global myocardial damage. We wanted to find out if the level of HEP (High energetic phosphates) can predict the best date for operation. This was the first attempt to assess quantitatively the energy metabolism in patients with valvular problems by 31P-MRS and to correlate it to their clinical status. 21 patients with aortal valve stenosis were investigated, 14 of them again after 3 months and 5 a second time after 1 year. We found out that patients will benefit the more from the operation the worse their pre-operative HEP-values were. Unfortunately, there is no simple correlation, therefore a single parameter can not predict the best date of operation. b) The second study group consisted of patients with myocardial infarction that is with a regional wall damage. They were investigated before and half a year after PTCA or bypass surgery. The aim was to evaluate the MRS for capacity and reliability in distinguishing vital from avital myocardium after infarction. This is important for the decision about the benefit for the damaged myocardium by cardiac surgery. In this study we included 50 patients. A significant difference in absolute HEP-values between patients and healthy volunteers could be shown. The differentiation between avital and "stunned" or "hibernating" myocardium was more difficult, and PCr/ATP alone seems to be not a sufficient parameter. MRS showed a 47 % sensitivity in comparision to gold-standard MRI. This is due to the low spatial resolution of MRS which impairs segmental evaluation (which is possible with MRI). C) The 31P-spectra were processed with 3 programmes, LUISE, AMARES, and SLOOP. The results were compared for validity, reliability, needed time for calculation etc.. Only SLOOP yields absolute quantitative values. Absolute values make the results comparable between different patients, different dates of investigation and different teams. But it requires 2 hours per calculation, which is impossible in clinical context. AMARES is presently the fastest and easiest method for obtaining 31P-spectra. KW - Herzinfarkt KW - Vitalitätsdiagnostik KW - 31P-MR-Spektroskopie KW - Aortenklappenersatz KW - myocardial infarction KW - vitality of heart muscle KW - 31P-MR-spectroscopy KW - aortal valve stenosis Y1 - 2002 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-5574 ER - TY - JOUR A1 - Veldhoen, Simon A1 - Behzadi, Cyrus A1 - Lenz, Alexander A1 - Henes, Frank Oliver A1 - Rybczynski, Meike A1 - von Kodolitsch, Yskert A1 - Bley, Thorsten Alexander A1 - Adam, Gerhard A1 - Bannas, Peter T1 - Non-contrast MR angiography at 1.5 Tesla for aortic monitoring in Marfan patients after aortic root surgery JF - Journal of Cardiovascular Magnetic Resonance N2 - Background: Contrast-enhanced cardiovascular magnetic resonance angiography (CE-CMRA) is the established imaging modality for patients with Marfan syndrome requiring life-long annual aortic imaging before and after aortic root replacement. Contrast-free CMRA techniques avoiding side-effects of contrast media are highly desirable for serial imaging but have not been evaluated in the postoperative setup of Marfan patients. The purpose of this study was to assess the feasibility of non-contrast balanced steady-state free precession (bSSFP) magnetic resonance imaging for aortic monitoring of postoperative patients with Marfan syndrome. Methods: Sixty-four adult Marfan patients after aortic root replacement were prospectively included. Fourteen patients (22%) had a residual aortic dissection after surgical treatment of type A dissection. bSSFP imaging and CE-CMRA were performed at 1.5 Tesla. Two radiologists evaluated the images regarding image quality (1 = poor, 4 = excellent), artifacts (1 = severe, 4 = none) and aortic pathologies. Readers measured the aortic diameters at defined levels in both techniques. Statistics included observer agreement for image scoring and diameter measurements and ROC analyses for comparison of the diagnostic performance of bSSFP and CE-CMRA. Results: Both readers observed no significant differences in image quality between bSSFP and CE-CMRA and found a median image quality score of 4 for both techniques (all p > .05). No significant differences were found regarding the frequency of image artifacts in both sequences (all p > .05). Sensitivity and specificity for detection of aortic dissections was 100% for both readers and techniques. Compared to bSSFP imaging, CE-CMRA resulted in higher diameters (mean bias, 0.9 mm; p < .05). The inter-observer biases of diameter measurements were not significantly different (all p > .05), except for the distal graft anastomosis (p = .001). Using both techniques, the readers correctly identified a graft suture dehiscence with aneurysm formation requiring surgery. Conclusion: Unenhanced bSSFP CMR imaging allows for riskless aortic monitoring with high diagnostic accuracy in Marfan patients after aortic root surgery. KW - MR angiography Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158693 VL - 19 IS - 82 ER - TY - THES A1 - Tschammler, Sabina T1 - Individuelle Anpassung des Röhrenstroms zur Dosisreduktion bei CT-Untersuchungen T1 - Individual selection of the tube current for dose reduction N2 - In der vorliegenden Arbeit sollte untersucht werden, welcher individuelle Röhrenstrom für unterschiedliche anatomische Regionen (Schädel, Hals, Thorax und Abdomen) nötig ist um diagnostisch aussagekräftige CT-Aufnahmen zu erzeugen. In diese prospektive Studie wurden 262 erwachsene Patienten aufgenommen. Ausgehend von seit Jahren bewährten Standardparametern wurde für jede anatomische Region anhand eines Iterationsschemas der minimal notwendige Röhrenstrom durch mehrmalige Wiederholung des Referenzscans ermittelt und mit diesem Wert die Untersuchung durchgeführt. Drei voneinander unabhängige Radiologen beurteilten die Bildqualität vor und nach Röhrenstromanpassung ohne Kenntnis der Expositionsparameter. Für Untersuchungen des Schädels (n=50) ergab sich ein Einsparungspotentials von 13 %, bei Thoraxuntersuchungen (n=67) von 57 % und bei Untersuchungen des Abdomens (n=119) eine maximale Einsparung von 45 % der Standarddosis. Dabei lag die Standarddosis für Schädel- (CTDIW= 41,7 mGy), Thorax- (CTDIW= 9,7 mGy) und Abdomenuntersuchungen (CTDIW = 11,7 mGy) bereits im untersten Quartil der deutschen Expositionspraxis. Für Abdomenuntersuchungen fand sich eine lineare Beziehung zwischen dem erforderlichen Röhrenstrom und dem in der a.p.-Richtung im Oberbauch gemessenen Körperdurchmesser. Der erforderliche Röhrenstrom variierte von 110 bis 325 mA (CTDIW=6,4-17,6 mGy) und die Körperdurchmesser von 16-35 cm. So ergibt sich, daß schlanke Patienten mit einem Durchmesser unter 27 cm bei den üblichen Expositionsparametern unnötig hohen Dosen ausgesetzt werden. Für diese Patienten kann man den notwendigen Röhrenstrom abschätzen, indem man den Körperdurchmesser mit ¾ multipliziert. Durch die individuelle Anpassung des Röhrenstroms an den Körperdurchmesser wird die Strahlenexposition bei Abdomen-CT-Untersuchungen um bis zu 45 % gesenkt ohne Beeinträchtigung der diagnostischen Aussagekraft. Für CT-Untersuchungen des Thorax ist das Einsparungspotential unabhängig vom Körperdurchmesser, im Mittel reicht ein Röhrenstrom von 73 mA (CTDIW= 4,2 mGy) aus. Bei CT-Untersuchungen des Gehirnschädels ergab sich das geringste Einsparpotential mit einer notwendigen Dosis CTDIW = 36,2 mGy bei durchschnittlich 174 mA. Der Studienarm Hals wurde vorzeitig wegen Zunahme von Aufhärtungsartefakten durch den Unterkiefer bzw. die Schulter abgebrochen. N2 - We searched for individual scan protocols which provide adequate diagnostic information with minimal radiation exposure in adult CT-examinations (cerebrum, neck, thorax and abdomen). In this prospective study 262 adults were examined using standard settings of each anatomical region. The individualised scan protocol was defined by repeating the reference scan with different tube current following a predefined iteration scheme. The examination was done with the lowest tube current which resulted a sufficient image quality. The image qualities with standard dose and with individual dose were evaluated independently by 3 different radiologists blinded to the exposition parameters. For the cerebrum (n=50) we found a dose reduction potential of 13 %, for the chest (n=67) of 57 % and for the abdomen a maximum reduction of up to 45 % compared with the standard settings without adverse affects on the diagnostic performance. The studies of the neck were untimely stopped due to artefacts caused in the mandible and the shoulder. The standard dose of the cerebrum (CTDIw = 41,7 mGy), of the thorax (CTDIw = 9,7 mGy) and of the abdomen (CTDIw = 11,7 mGy). We want to mention that our standard dose was in the lowest quartile of the actual German radiation dose survey. For abdominal examinations we found a linear relation between individualised dose and the anterior-posterior (a.p.) diameter of the patients. Patient diameters in a.p. direction varied from 16 to 35 cm and correlated with individualised tube currents from 110 to 325 mA (CTDIw = 6,4 - 17,6 mGy). Slim patients with a diameter lower than 27 cm in the epigastric area receive unnecessary high doses using the standard exposition parameters. For these patients you can estimate the necessary tube current multiplying the a.p. diameter with 3/4. For thoracal CT-examinations the dose reduction potential is independent on the physical diameter, on average a tube current of 73 mA (CTDIw = 4,2 mGy) is necessary. For examinations of the cerebrum there is the lowest dose reduction potential with a needed dose (CTDIw = 36,2 mGy) with an average value of 174 mA. KW - Dosisreduktion KW - Röhrenstromanpassung KW - Computertomographie KW - Strahlenexposition KW - Bildqualität KW - dose reduction KW - computed tomography KW - exposure of radiation KW - image quality KW - tube current modulation Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12273 ER - TY - THES A1 - Trumpp, Melanie Liane T1 - Vergleich verschiedener Auswerteverfahren für die Bestimmung der Myokardperfusion in der MRT T1 - Comparison of various parameters in the MRT assessment of myocardial perfusion N2 - In der Diagnostik der KHK und für die richtige Therapieentscheidung ist die myokardiale Perfusion von besonderem Interesse. Die verminderte Mikrozirkulation als funktionelle Folge einer Stenose korreliert mit den Beschwerden und der Prognose für einen Patienten mit KHK besser als die Morphologie der Stenose selbst. In der koronaren Angiographie wird die vaskuläre Situation der Herzkranzgefäße beurteilt und in Stenosegrade eingeteilt. Die Stenosen bedingen aber häufig nicht die entsprechende myokardiale Minderdurchblutung, so dass oft zusätzliche Untersuchungen der Ischämiediagnostik wie beispielsweise die Myokardszintigraphie oder die Stressechokardiographie erforderlich sind. Die MR-Perfusionsmessung kann bereits zur KHK-Primärdiagnostik eingesetzt werden. Die Bestimmung der hämodynamischen Relevanz einer Stenose und der Nachweis einer mikrovaskulärern Obstruktion nach Infarkt und die Therapiekontrolle nach Revaskularisierung ist möglich. Hier könnte in Zukunft die quantitative MR Perfusionsmessung den Vergleich von MR Perfusionsmessungen mit anderen Modalitäten erleichtern. Die Magnetresonanztomographie für die Bestimmung der Herzperfusion wird zunehmend in der Klinik angewendet. Die Auswertung erfolgt in der Regel nicht quantitativ, sondern rein visuell. Die quantitative Bestimmung der myokardialen Perfusion mittels MRT ist Gegenstand der aktuellen Forschung. In der vorliegenden Arbeit wurde die von Köstler beschriebene Präbolus Technik eingesetzt, die quantitative Aussagen über die myokardiale Perfusion mit einer geringen Variabilität ermöglicht. Diese Untersuchungstechnik wurde bei herzgesunden Probanden getestet. Für die quantitativen Perfusionsuntersuchungen wurde das Myokard in allen Bildern manuell segmentiert (d.h. markiert). Anschließend wurden aus den segmentierten Bildern Konzentrations-Zeit-Kurven im Myokard und im linken Ventrikel bestimmt. Aus diesen Kurven wurden durch Entfaltung mit der arteriellen Inputfunktion zu einer Modellfunktion quantitative Werte für die Perfusion gemessen. Das Ziel dieser Studie war die Untersuchung verschiedener Aspekte der Auswerteverfahren in der Herzperfusionsdiagnostik, um die Auswertung optimieren zu können. Die Untersuchungen für die quantitative Bestimmung der Myokardperfusion erfolgten mittels Präbolus-Technik und einer Multislice SSFP-Sequenz. Zur Bestimmung einer optimierten Segmentation des Myokards bei der quantitativen Bestimmung der Herzperfusion in der MRT ist es möglich, die tatsächlichen Myokardgrenzen zu verwenden, wenn eine Kontaminationskorrektur eingesetzt wird. Dabei wird das Signal-zu-Rausch-Verhältnis verbessert und die Variabilität der Perfusionswerte vermindert. Die subendokardiale und subepikardiale Perfusion können bestimmt werden. Die Untersuchung der Perfusion der subendo- und subepikardialen Schicht des menschlichen Herzens zeigte bei den untersuchten gesunden Probanden eine höhere Perfusion der subendokardialen Anteile. Künftig könnten auch in der klinischen Routine subendo- und subepikardiale Schichten getrennt ausgewertet werden, um somit eine Differenzierung eines Perfusionsdefizites zu ermöglichen. Ziel ist es, auch kleine Durchblutungsstörungen oder eine Minderdurchblutung nur der inneren Schichten des Herzmuskels quantitativ nachzuweisen. Hierzu müssen die Ergebnisse dieser Studie mit Ergebnissen von Patienten verglichen werden. Werden die Werte von quantitativen Perfusionsauswertungen mit einer Fermi- oder Exponentialfunktion ausgewertet, zeigt sich ein linearer Zusammenhang der Ergebnisse, die ineinander umgerechnet werden können. Beide Modellfunktionen sind somit für die Auswertung der Herzperfusionsuntersuchung einsetzbar. Des Weiteren wurde gezeigt, dass es durch die Entfaltung der Konzentrations-Zeit-Kurven möglich ist, die myokardiale Perfusion bei gesunden Probanden korrekt zu messen, auch wenn nur die Bilder jedes n-ten Herzschlages berücksichtigt werden. Patientenstudien müssen zeigen, ob dies auch für minderperfundierte Areale zutrifft und ob diese eindeutig determiniert werden können. Die Interobservervariabilität liegt in der Größenordung der Streuung der Flusswerte bei gesunden Probanden. Die Beurteilbarkeit unterschiedlicher Regionen des Herzens hinsichtlich der Mikrozirkulation und der daraus abzuleitenden therapeutischen Konsequenzen sind das primäre Ziel. Mit der quantitativen MR-Herz-Perfusionsmessung soll ein validiertes diagnostisches Instrumentarium für die Bestimmung der Herzdurchblutung zur Verfügung gestellt werden. Diese Arbeit liefert einen Beitrag zur Optimierung der Auswertung der Herzperfusion und hilft damit den Stellenwert der MR-Herzperfusionsmessung zu verbessern. Die MRT könnte auf Grund der hohen räumlichen Auflösung und der Möglichkeit der Quantifizierung in Zukunft zum Goldstandard bei Herzperfusionsuntersuchungen werden N2 - In the work-up of coronary artery disease (CAD) and in order to choose the right therapy, the assessment of myocardial perfusion is of special interest. The diminished mirco-circulation resulting from a stenotic coronary vessel correlates with the complaints and prognosis of patients better than the morphology of the stenosis. In coronary angiography, the vascular status is assessed and extend of the stenosis is graded. Since the grade of a stenosis does not always correlate with the extend of reduced myocardial perfusion, additional tests such as radionuclide myocardial perfusion imaging or stress echocardiography are necessary to further asses myocardial ischemia. The measurement of myocardial perfusion by MR can already be used for the initial work-up of CAD. It is possible to assess the hemodynamic relevance of a stenosis and to detect microvascular obstructions after infarction as well as to perform reassessment of the status after intervention. In the future, quantitative MR perfusion measurements could facilitate the correlation and comparison with other imaging modalities. MRT studies of myocardial perfusion are increasingly being used in clinical routine. The analysis of the studies is commonly not performed in a quantitative but visual way. The quantification of myocardial perfusion by MR is the focus of current research. In this work the prebolus technique introduced by Köstler was used to obtain quantitative low-variation data on myocardial perfusion. This technique has been tested already in healthy volunteers. For the quantitative assessment of perfusion the myocardium was manually segmented (marked) on all images. Subsequently the concentration-time-curves for the myocardium and the left ventricle were generated using the segmented images. By using deconvolution with the arterial input function on the myocardial curves quantitative values of myocardial perfusion could be obtained. The aim of this study was to optimize various parameters in the MRT assessment of myocardial perfusion. The studies for the quantification of myocardial perfusion were conducted using a prebolus technique and a multislice SSFP sequence. For the determination of the optimal segmentation of the myocardium it is possible to use the actual borders of the myocardium if a correction for contamination is applied. Thereby the signal-to-noise-ratio is being improved and the variability of the deteremined perfusion values is reduced. Both, subendocardial and subepicardial perfusion can be assessed When those parameters are determined in healthy volunteers, higher values are found in the subendocardial areas. In the future subendo- and subepicardial areas could also be analysed in clinical routine diagnostics for the identification of perfusion deficits. The goal is, to be able to detect and quantify even small perfusion deficits existing only in the inner layer of the myocardium. In order to achieve this, the results of this study need to be verified in patients. When the quantitative assessment of perfusion is performed using either the Fermi- or the exponential function a linear correlation of the respective results is observed. Both model functions therefore are suitable for the determination of myocardial perfusion. Furthermore it is shown, that using deconvolution of the concentration-time-curves it is possible to correctly measured myocardial perfusion in healthy volunteers by only using a fraction of the heart beats. Studies in patients are needed in order to be able to assess, if this holds true for areas of decreased perfusion. The inter-observer variability is in the same range as the variation of values in healthy volunteers. The assessability of various myocardial regions with regard to microcirculation and the corresponding therapeutic consequences are the primary goal. With the quantitative MR- measurement of myocardial perfusion a new validated tool should be provided as a new diagnostic tool. This work has a share in optimizing the analysis of myocardial perfusion and increases the value of the MR-based assessment of myocardial perfusion. MRT, due to the higher spatial resolution and the possibility of quantification, could become the gold standard in myocardial perfusion imaging. KW - MRT-Tomographie KW - Herzinfarkt KW - MRT KW - mikrovaskuläre Obstruktion KW - First pass KW - Präbolus Technik KW - MRI KW - microvascular obstruction KW - first pass KW - prebolus technique Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-29377 ER - TY - THES A1 - Trebin, Amelie T1 - Entwickelt sich eine Meningeose beim Medulloblastom gleichmäßig kranial und spinal? T1 - Is the development of meningeosis in medulloblastomas uniformly cranial and spinal? N2 - In der Nachsorge des Medulloblastoms wird standardmäßig auf die Bildgebung mittels Magnetresonanztomographie zurück gegriffen. Da die Erkrankung vor allem entlang der Liquorwege in Form einer kranialen oder spinalen Meningeose metastasiert, wurde anhand Daten der Therapieoptimierungsstudie "HIT 2000" verglichen, welche Lokalisation am häufigsten betroffen ist. Es zeigte sich, dass zu einem hohen Prozentanteil vor allem eine kombinierte Meningeose im Rezidiv oder Progress auftritt, gefolgt von einer kranialen Metastasierung. Dennoch gibt es eine Gruppe an Patienten, die eine isolierte spinale Meningeose entwickeln. N2 - In the follow-up of patients with medulloblastoma, the MRI has been established as standard procedure. The tumor most often spreads via the cerebrospinal fluid as cranial oder spinal meningeoses. We compared the frequency of progress or relapse in children undergoing treatment according to the "HIT 2000" protocol. There could be shown, that the most common localization of meningeosis is both cranial and spinal, followed by isolated cranial meningeosis. Nevertheless there is a group of patients, developing an isolated spinal meningeosis. KW - Kernspintomographie KW - Metastase KW - Hirntumor KW - Meningeose KW - Medulloblastom KW - kranial KW - Meningeosis KW - Medulloblastoma KW - cranial KW - spinal Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-92226 ER - TY - JOUR A1 - Traub, Jan A1 - Grondey, Katja A1 - Gassenmaier, Tobias A1 - Schmitt, Dominik A1 - Fette, Georg A1 - Frantz, Stefan A1 - Boivin-Jahns, Valérie A1 - Jahns, Roland A1 - Störk, Stefan A1 - Stoll, Guido A1 - Reiter, Theresa A1 - Hofmann, Ulrich A1 - Weber, Martin S. A1 - Frey, Anna T1 - Sustained increase in serum glial fibrillary acidic protein after first ST-elevation myocardial infarction JF - International Journal of Molecular Sciences N2 - Acute ischemic cardiac injury predisposes one to cognitive impairment, dementia, and depression. Pathophysiologically, recent positron emission tomography data suggest astroglial activation after experimental myocardial infarction (MI). We analyzed peripheral surrogate markers of glial (and neuronal) damage serially within 12 months after the first ST-elevation MI (STEMI). Serum levels of glial fibrillary acidic protein (GFAP) and neurofilament light chain (NfL) were quantified using ultra-sensitive molecular immunoassays. Sufficient biomaterial was available from 45 STEMI patients (aged 28 to 78 years, median 56 years, 11% female). The median (quartiles) of GFAP was 63.8 (47.0, 89.9) pg/mL and of NfL 10.6 (7.2, 14.8) pg/mL at study entry 0–4 days after STEMI. GFAP after STEMI increased in the first 3 months, with a median change of +7.8 (0.4, 19.4) pg/mL (p = 0.007). It remained elevated without further relevant increases after 6 months (+11.7 (0.6, 23.5) pg/mL; p = 0.015), and 12 months (+10.3 (1.5, 22.7) pg/mL; p = 0.010) compared to the baseline. Larger relative infarction size was associated with a higher increase in GFAP (ρ = 0.41; p = 0.009). In contrast, NfL remained unaltered in the course of one year. Our findings support the idea of central nervous system involvement after MI, with GFAP as a potential peripheral biomarker of chronic glial damage as one pathophysiologic pathway. KW - myocardial infarction KW - STEMI KW - glial fibrillary acidic protein KW - GFAP KW - neurofilament light chain KW - NfL KW - glial damage KW - cardiac magnetic resonance imaging KW - MRI KW - infarction size Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-288261 SN - 1422-0067 VL - 23 IS - 18 ER - TY - JOUR A1 - Tran-Gia, Johannes A1 - Wech, Tobias A1 - Bley, Thorsten A1 - Köstler, Herbert T1 - Model-Based Acceleration of Look-Locker T1 Mapping JF - PLoS One N2 - Mapping the longitudinal relaxation time \(T_1\) has widespread applications in clinical MRI as it promises a quantitative comparison of tissue properties across subjects and scanners. Due to the long scan times of conventional methods, however, the use of quantitative MRI in clinical routine is still very limited. In this work, an acceleration of Inversion-Recovery Look-Locker (IR-LL) \(T_1\) mapping is presented. A model-based algorithm is used to iteratively enforce an exponential relaxation model to a highly undersampled radially acquired IR-LL dataset obtained after the application of a single global inversion pulse. Using the proposed technique, a \(T_1\) map of a single slice with 1.6mm in-plane resolution and 4mm slice thickness can be reconstructed from data acquired in only 6s. A time-consuming segmented IR experiment was used as gold standard for \(T_1\) mapping in this work. In the subsequent validation study, the model-based reconstruction of a single-inversion IR-LL dataset exhibited a \(T_1\) difference of less than 2.6% compared to the segmented IR-LL reference in a phantom consisting of vials with \(T_1\) values between 200ms and 3000ms. In vivo, the \(T_1\) difference was smaller than 5.5% in WM and GM of seven healthy volunteers. Additionally, the \(T_1\) values are comparable to standard literature values. Despite the high acceleration, all model-based reconstructions were of a visual quality comparable to fully sampled references. Finally, the reproducibility of the \(T_1\) mapping method was demonstrated in repeated acquisitions. In conclusion, the presented approach represents a promising way for fast and accurate \(T_1\) mapping using radial IR-LL acquisitions without the need of any segmentation. KW - algorithms KW - cerebrospinal fluid KW - NMR relaxation KW - data acquisition KW - relaxation (physics) KW - relaxation time KW - central nervous system KW - magnetic resonance imaging Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126436 VL - 10 IS - 4 ER - TY - THES A1 - Tran-Gia, Johannes T1 - Model-Based Reconstruction Methods for MR Relaxometry T1 - Modellbasierte Rekonstruktionsmethoden für die MR-Relaxometrie N2 - In this work, a model-based acceleration of parameter mapping (MAP) for the determination of the tissue parameter T1 using magnetic resonance imaging (MRI) is introduced. The iterative reconstruction uses prior knowledge about the relaxation behavior of the longitudinal magnetization after a suitable magnetization preparation to generate a series of fully sampled k-spaces from a strongly undersampled acquisition. A Fourier transform results in a spatially resolved time course of the longitudinal relaxation process, or equivalently, a spatially resolved map of the longitudinal relaxation time T1. In its fastest implementation, the MAP algorithm enables the reconstruction of a T1 map from a radial gradient echo dataset acquired within only a few seconds after magnetization preparation, while the acquisition time of conventional T1 mapping techniques typically lies in the range of a few minutes. After validation of the MAP algorithm for two different types of magnetization preparation (saturation recovery & inversion recovery), the developed algorithm was applied in different areas of preclinical and clinical MRI and possible advantages and disadvantages were evaluated. N2 - Im Rahmen dieser Arbeit wurde ein modellbasiertes Verfahren namens MAP (engl. Model-based Acceleration of Parameter mapping) für die Bestimmung des T1-Gewebeparameters mittels Magnetresonanztomographie (MRT) entwickelt. Dieser iterative Algorithmus verwendet das Vorwissen über den nach einer Magnetisierungspräparation zu erwartenden Signalverlauf, um aus einer im Anschluss an eine initiale Präparation aufgenommene zeitliche Serie stark unterabgetasteter k-Räume eine Serie voll abgetasteter k-Räume zu generieren.Eine Fourier-Transformation dieser Serie in den Bildraum zeigt den örtlich aufgelösten zeitlichen Verlauf der longitudinalen Relaxation, was eine Kartierung des Gewebeparameters T1 ermöglicht. In seiner schnellsten Form ermöglicht dieses Verfahren die Rekonstruktion einer T1-Karte aus einem innerhalb weniger Sekunden nach einer passenden Magnetisierungspräparation aufgenommenen radialen Gradienten-Echo-Datensatz, während die Messdauer herkömmlich verwendeter T1-Bestimmungstechniken üblicherweise im Bereich von einigen Minuten liegt. Nach der Validierung des MAP-Algorithmus für zwei unterschiedliche Arten der Magnetisierungspräparation (Sättigungspräparation, Inversion) wurde die entwickelte Technik im Rahmen dieser Arbeit in verschiedenen Bereichen der präklinischen und klinischen MRT angewendet und mögliche Vor- und Nachteile untersucht. KW - Kernspintomographie KW - Radiologische Diagnostik KW - Bildgebendes Verfahren KW - Magnetic Resonance Relaxometry KW - Magnetresonanz-Relaxometrie KW - Model Based Reconstruction Algorithms in Magnetic Resonance Imaging KW - Modellbasierte-Rekonstruktionsalgorithmen in der Magnetresonanztomografie KW - Relaxation Parameter Mapping in Magnetic Resonance Imaging KW - Bestimmung des Relaxations-Parameters in der Magnetresonanztomografie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-109774 ER - TY - JOUR A1 - Torkzad, Michael R. A1 - Masselli, Gabriele A1 - Halligan, Steve A1 - Oto, Aytek A1 - Neubauer, Henning A1 - Taylor, Stuart A1 - Gupta, Arun A1 - Frøkjær, Jens Brøndum A1 - Lawrance, Ian C. A1 - Welman, Christopher J. A1 - Negård, Anne A1 - Ekberg, Olle A1 - Patak, Michael A1 - Lauenstein, Thomas T1 - Indications and selection of MR enterography vs. MR enteroclysis with emphasis on patients who need small bowel MRI and general anaesthesia: results of a survey JF - Insights into Imaging N2 - Aims To survey the perceived indications for magnetic resonance imaging of the small bowel (MRE) by experts, when MR enteroclysis (MREc) or MR enterography (MREg) may be chosen, and to determine how the approach to MRE is modified when general anaesthesia (GA) is required. Materials and methods Selected opinion leaders in MRE completed a questionnaire that included clinical indications (MREg or MREc), specifics regarding administration of enteral contrast, and how the technique is altered to accommodate GA. Results Fourteen responded. Only the diagnosis and follow-up of Crohn’s disease were considered by over 80 % as a valid MRE indication. The remaining indications ranged between 35.7 % for diagnosis of caeliac disease and unknown sources of gastrointestinal bleeding to 78.6 % for motility disorders. The majority chose MREg over MREc for all indications (from 100 % for follow-up of caeliac disease to 57.7 % for tumour diagnosis). Fifty per cent of responders had needed to consider MRE under GA. The most commonly recommended procedural change was MRI without enteral distention. Three had experience with intubation under GA (MREc modification). Conclusion Views were variable. Requests for MRE under GA are not uncommon. Presently most opinion leaders suggest standard abdominal MRI when GA is required. KW - small bowel MRI KW - Crohn’s disease KW - general anaesthesia Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-149847 VL - 6 IS - 3 ER - TY - THES A1 - Toepell, Andreas Daniel T1 - Quantifizierung von kardialen Metaboliten mittels akquisitionsgewichteter 31P-MR-Spektroskopie: Optimierung der SLOOP-Auswertung N2 - Die 31P-MRS wird zur Diagnostik des Energiemetabolismus bei verschiedenen kardialen Erkrankungen eingesetzt. Die vorliegende Arbeit befasst sich mit einer Verbesserung und Vereinfachung der Quantifzierung kardialer Energiemetaboliten mittels der 31P-MRS. Durch Akquisitonsgewichtung kann eine genauere Beurteilung der Konzentrationen von PCr und ATP im gesunden Myokard durch Verbesserung der Effizienz und Sensitivität der 31P-MRS erreicht werden. Die Kontamination des MR-Signals durch die Brustwand wird mittels des CORRECT-SLIM-Algorithmus verringert. Eine Fallstudie am rechten Ventrikel zeigt die starke metabolische Aussagekraft der 31P-MRS vor, während und nach medikamentöser Therapie. Die 31P-MRS unter Verwendung räumlicher Sättigungspulse liefert einen unmittelbaren Einblick in den Energiemetabolismus des menschlichen Herzens mit einer deutlich kürzen Nachbearbeitungszeit. Durch diese Optimierungen ermöglicht die 31P-MRS des menschlichen Herzens eine exakte Beurteilung des Energiemetabolismus im gesunden wie erkrankten Myokard. KW - NMR-Tomographie KW - Herzstoffwechsel KW - Phosphor KW - Quantifizierung KW - MRI KW - myocardium KW - phosphor Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-43644 ER - TY - JOUR A1 - Thurner, Annette A1 - Augustin, Anne Marie A1 - Bley, Thorsten Alexander A1 - Kickuth, Ralph T1 - 2D-perfusion angiography for intra-procedural endovascular treatment response assessment in chronic mesenteric ischemia: a feasibility study JF - BMC Medical Imaging N2 - Background Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI. Methods 49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated. Results Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PD\(_{outflow}\)/PD\(_{inflow}\) increased by 65% (p < 0.001) and AUC\(_{outflow}\)/AUC\(_{inflow}\) increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05). Conclusions Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results. KW - 2D-perfusion angiography KW - chronic mesenteric ischemia KW - endovascular treatment KW - mesenteric stenting Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301131 VL - 22 ER - TY - THES A1 - Thein, Irina T1 - Monochromatische DSA versus farbkodierte DSA in der Entscheidungsfindung zur Stentimplantation bei pAVK T1 - Evaluation of superficial femoral artery lesions after percutaneous transluminal angioplasty: color-coded summation vs. monochromatic digital subtraction angiography N2 - In der vorliegenden Arbeit wurde untersucht, ob die farbige DSA-Darstellungsweise besser als die monochromatische dazu geeignet ist, eine Entscheidung über eine mögliche Stentimplantation bei pAVK zu treffen. Hierfür wurden DSA-Daten des Universitätsklinikums Würzburg im Zeitraum 04/2014 - 10/2015 retrospektiv ausgewertet. Drei Ärzte bewerteten die Bilder in zwei getrennten Durchgängen bezüglich ihrer Entscheidung zur Stentimplantation. Diese Entscheidungen wurden mit einem Konsensus aus 2 Ärzten verglichen. Anhand von ROC-Analysen konnte so die Treffsicherheit der Entscheidungen evaluiert werden. In der Studie stellte sich die farbkodierte Darstellung im Vergleich zur monochromatischen Darstellung nicht als überlegen heraus. N2 - The present paper analyses if color-coded DSA is more suitable than conventional monochromatitic DSA to decide on a possible stent implantation for a pAVK-lesion. Therefor DSA-Data of the University Hospital of Würzburg was evaluated retrospectively of the period from 04/2014 – 10/2015. Three doctors assessed the pictures in two separate cycles in terms of their decision concerning stenting. These decisions were compared with a consensus of two doctors. The accuracy of the decisions were evaluated based on ROC-analyses. In this study, color coded DSA did not prove to be superior to conventional DSA. KW - Digitale Subtraktionsangiographie KW - Periphere arterielle Verschlusskrankheit KW - ROC-Kurve KW - farbkodierte DSA Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-240562 ER - TY - JOUR A1 - Stich, Manuel A1 - Pfaff, Christiane A1 - Wech, Tobias A1 - Slawig, Anne A1 - Ruyters, Gudrun A1 - Dewdney, Andrew A1 - Ringler, Ralf A1 - Köstler, Herbert T1 - The temperature dependence of gradient system response characteristics JF - Magnetic Resonance in Medicine N2 - Purpose: The gradient system transfer function (GSTF) characterizes the frequency transfer behavior of a dynamic gradient system and can be used to correct non‐Cartesian k‐space trajectories. This study analyzes the impact of the gradient coil temperature of a 3T scanner on the GSTF. Methods: GSTF self‐ and B\(_0\)‐cross‐terms were acquired for a 3T Siemens scanner (Siemens Healthcare, Erlangen, Germany) using a phantom‐based measurement technique. The GSTF terms were measured for various temperature states up to 45°C. The gradient coil temperatures were measured continuously utilizing 12 temperature sensors which are integrated by the vendor. Different modeling approaches were applied and compared. Results: The self‐terms depend linearly on temperature, whereas the B0‐cross‐term does not. Effects induced by thermal variation are negligible for the phase response. The self‐terms are best represented by a linear model including the three gradient coil sensors that showed the maximum temperature dependence for the three axes. The use of time derivatives of the temperature did not lead to an improvement of the model. The B\(_0\)‐cross‐terms can be modeled by a convolution model which considers coil‐specific heat transportation. Conclusion: The temperature dependency of the GSTF was analyzed for a 3T Siemens scanner. The self‐ and B0‐cross‐terms can be modeled using a linear and convolution modeling approach based on the three main temperature sensor elements. KW - gradient impulse response function KW - gradient system respose KW - gradient system trasfer function KW - temperature dependency KW - thermal variation Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-206212 VL - 83 ER - TY - THES A1 - Stetter, Christian E. T1 - In vivo Untersuchung des kardialen Stoffwechsels bei Morbus Fabry mittels 31Phosphor-MR-Spektroskopie T1 - Cardiac metabolism in Fabry disease measured in vivo with 31Phosphor Magnetic Resonance Spectroscopy N2 - Der Morbus Fabry ist eine lysosomale Speicherkrankheit, die auf einem Mangel des Enzyms a-Galaktosidase A beruht. Die Krankheit wird X-chromosomal rezessiv vererbt und entsteht durch Mutation des a-Galaktosidase-Gens auf dem langen Arm des Chromosoms Xq22. Durch die erniedrigte bzw. fehlende Enzymaktivität kommt es zu einer übermäßigen Ablagerung von Glykosphingolipiden in sämtlichen Geweben des menschlichen Körpers, besonders betroffen sind Herz, Nieren, Gefäße und ZNS. Die Krankheit ist durch einen progredienten Verlauf und einer eingeschränkten Lebenserwartung gekennzeichnet. Insbesondere die kardialen Auswirkungen wie Herzrhythmusstörungen, Klappenvitien und linksventrikuläre Hypertrophie führen zur Herzinsuffizienz und fast immer zu einem meist frühzeitigen Tod durch Herzversagen. Seit einiger Zeit steht in der Enzymersatztherapie mit rekombinanter a-Galaktosidase A (Agalsidase) eine kausale Behandlung zur Verfügung. Unter der Therapie mit Agalsidase zeigen sich auch Verbesserungen der kardialen Parameter, insbesondere eine Reduktion der linksventrikulären Masse. Zur Kontrolle und zur Dokumentation der medikamentösen Wirkung an den verschiedenen Organen waren und sind klinische Studien und Untersuchungen der betroffenen Patienten notwendig. Zur Beurteilung der kardialen Funktion steht, neben den bekannten Routineverfahren wie der Echokardiographie und der MR-Bildgebung, mit der 31P-Magnetresonanz-Spektroskopie ein nicht invasives Verfahren zur Beurteilung des myokardialen Stoffwechsels zur Verfügung. Mit Hilfe von speziellen Auswerteprogrammen können die Absolutkonzentrationen von energiereichen Metaboliten, besonders von Phosphokreatin und Adenosintriphosphat, im Herzmuskel in vivo bestimmt werden. Ziel der vorliegenden Arbeit war zunächst einmal die Messung der Konzentrationen der energiereichen Metabolite im Myokard von Patienten mit Morbus Fabry und der Vergleich der Daten mit denen von gesunden Probanden. Des weiteren wurde die Patientengruppe unter Therapie mit Agalsidase b einer frühen und einer späten Kontrolluntersuchung mittels MR-Spektroskopie unterzogen, um Veränderungen im kardialen Metabolismus darzustellen. Die spektroskopischen Daten gaben Aufschluss über Ausmaß der Beeinträchtigung des myokardialen Stoffwechsels aufgrund der Gb3-Ablagerungen und ergänzten die klinischen und bildmorphologischen Untersuchungen. Hierbei konnte eine tendenzieller Anstieg der PCr- und ATP-Konzentrationen unter ERT im Myokard nachgewiesen werden, gleichfalls zeigten sich in dem untersuchten Kollektiv eine Abnahme der linksventrikulären Masse und eine erhöhte Ejektionsfraktion. Ebenso konnte dargelegt werden, dass wie auch bei anderen Herzerkrankungen, wie zum Beispiel der dilatativen Kardiomyopathie oder der koronaren Herzkrankheit, bei einer Stoffwechselerkrankung wie der Fabry-Krankheit deutlich verringerte Konzentrationen energiereicher Phosphate in den Herzmuskelzellen vorliegen. N2 - Fabry disease is a X-linked inborn metabolic defect of the lysosomal enzyme a-galactosidase A. The lack of a-galactosidase A causes an intracellular accumulation of glycosphingolipids, mainly globotriaosylceramide. The signs and symptoms of this disease are various, mainly affected organs are heart, kidneys, vascular endothelium, brain and the nervous system. Cardiac involvement is frequent and leads to progressive heart failure. Beside supportive treatment of the symptoms, a new specific therapy with recombinant enzyme is now available. Examination of the cardiac function of patients undergoing enzyme replacement therapy is necessary and only 31P magnetic resonace spectroscopy allows a non-invasive asessment of high-energy metabolites in the myocardium. KW - NMR-Spektroskopie KW - Fabry-Krankheit KW - NMR-Tomographie KW - Herzstoffwechsel KW - Fabry disease KW - MR-spectroscopy KW - cardiac metabolism KW - cardiac spectroscopy Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-27344 ER - TY - THES A1 - Stephan, Maximilian T1 - Perkutane mechanische Rotationsthrombektomie: Die Wertigkeit im Rahmen der akuten Extremitätenischämie T1 - Percutaneous Mechanical Thrombectomy in Acute and Subacute Lower- extremity Ischemia: Impact of adjunctive, solely non- thrombolytic endovascular procedures N2 - Die akute Extremitätenischämie ist ein klinischer Notfall, der in Abhängigkeit der Dauer und der Ausprägung klinischer Symptome interventionell und chirurgisch behandelt werden kann. Ziel dieser Studie war es, den klinischen und technischen Erfolg der primären interventionellen Therapie der akuten Extremitätenischämie zu untersuchen und die Bedeutung der Anwendung und Kombination primär nicht-thrombolytischer Verfahren zu eruieren. Als zusätzliche Zielparameter wurden die Mortalitätsrate, die Komplikationsrate, das amputationsfreie Überleben sowie das reischämiefreie Intervall evaluiert. Im Rahmen unserer Studie wurden 165 Patienten (89 männlich: 53,9%, 76 weiblich: 46,1%, Altersmittelwert: 77,5 Jahre, STABW ± 13,1 Jahre) und 167 Extremitäten (links n = 84, rechts n = 83) retrospektiv untersucht. Während der stationären Aufnahme wurden das Verschlussalter ermittelt (perakut bis chronisch), die Art des Verschlusses (komplett vs. inkomplett), die Lokalisation und Genese des Verschlusses sowie die Risikofaktoren der Patienten. Der technische Erfolg wurde radiologisch mithilfe des TIMI-Scores erhoben, der klinische Erfolg wurde während des stationären Aufenthalts und im Rahmen des Follow-ups beurteilt. Die Mehrheit der Verschlüsse (60,5 %, n = 101) war weniger als 7 Tage alt und präsentierte sich klinisch als eine inkomplette Ischämie (n = 147, 88%). Die Okklusion reichte in 63,5 % nicht über das POP II Segment hinaus. Ursächlich war bei n = 107 der 167 Extremitäten (64,1 %) ein „akut auf chronischer“ Verschluss bei vorbestehender pAVK, in n = 41 Fällen eine Thrombembolie (24,6 %) und in n = 19 Extremitäten eine arterielle Thrombose (11,4 %). Bei allen behandelten Extremitäten handelte es sich um einen primären Eingriff, der mittels perkutaner mechanischer Rotationsthrombektomie durchgeführt wurde. Dieser wurde bei n = 152 Verschlüssen (91 %) mit anderen (nicht thrombolytischen) interventionellen Verfahren kombiniert. Dabei wurden n = 66 Verschlüsse (39,5 %) mit einer mehrfachen Kombination aus PTA, Stent und/oder konventioneller PAT behandelt. Bei weiteren n = 43 Interventionen (25,7 %) reichte eine alleinige zusätzliche Stentimplantation aus, bzw. bei n = 33 Okklusionen (19,8 %) eine alleinige zusätzliche PTA. Lediglich in n = 15 Fällen (9 %) wurde die PMT ohne additive endovaskuläre Verfahren durchgeführt. Wir konnten in 92,2 % der Fälle (n = 154 Eingriffen) einen primären technischen und auch klinischen Erfolg beobachten. Insgesamt lag die reischämie-/reinterventionsfreie Rate nach 30 Tagen bei 86,2 %. Die reischämie-/reinterventionsfreie Rate betrug nach 6, 12, 24 und 36 Monaten jeweils 75,6%, 69,7%, 67,1% und respektive 64,4%. Die Amputationsrate betrug nach 30 Tagen 6,3 %, nach 6 Monaten 9 % und nach einem Jahr 11,2 %. Insgesamt verstarben n = 76 von den initial 165 Patienten (46,1 %) innerhalb des Nachbeobachtungs-zeitraums von 31,8 Monaten (STABW ± 24 Monate). Nach 30 Tagen lag das Gesamtüberleben bei 91 %, nach 6 Monaten bei 83,8 % und nach einem Jahr bei 77,2 %. Drei Patienten verstarben innerhalb der ersten 24 Stunden nach dem Eingriff, was entweder auf die Intervention oder die Kontrastmittel- und Volumenbelastung zurückzuführen war und als F-Komplikation zu werten ist. In 4,2 % der Fälle (n = 7) konnte die akute Extremitätenischämie nicht suffizient endovaskulär behandelt werden. Bei n = 6 Eingriffen (3,6 %) kam es zu Minorkomplikationen und in n = 8 weiteren Fällen zu Majorkomplikationen. Darunter waren die häufigsten Komplikationen das Kompartmentsyndrom (n = 4, 2,4 %) und die distale Embolisation (n = 4, 2,4 %) ohne anschließende Möglichkeit der erfolgreichen Thrombusbergung. Alle anderen n = 146 Eingriffe (87,4 %) verliefen komplikationslos. N2 - Purpose: To evaluate the role of adjunctive, solely non-thrombolytic endovascular therapy in treatment of acute lower-extremity ischemia by rotational percutaneous mechanical thrombectomy. Methods: Retrospective, single center evaluation of 165 patients (167 limbs) that underwent rotational percutaneous mechanical thrombectomy between 2009 and 2016. Results: Rotational percutaneous mechanical thrombectomy was used as a single therapy in 9.0% (15 limbs), followed by percutaneous aspiration thrombectomy in 6.0% (10 limbs), percutaneous transluminal angioplasty in 19.8% (33 limbs) and stenting in 25.7% (43 limbs). Rotational percutaneous mechanical thrombectomy was followed by any combination of these 3 interventions in 39.5%. Clinical and technical success was documented in 92.2%, complications in 10.3% (n=17). No significant difference in clinical and technical success was observed using rotational percutaneous mechanical thrombectomy alone or with additional endovascular therapy. On a long term basis, the re-ischemia free survival was nearly twice as high as in previous studies that reported more cases treated by rotational percutaneous mechanical thrombectomy alone. Conclusion: To assure a long-lasting primary patency after percutaneous mechanical thrombectomy concomitant treatment of underlying lesions with adjunctive, non-thrombolytic endovascular methods should be considered. KW - Notfallmedizin KW - Akute Extremitätenischämie KW - acute lower-extremity ischemia KW - Radiologie KW - Amputation KW - Kritische Extremitätenischämie KW - interventionelle Radiologie KW - perkutane Rotationsthrombektomie KW - arteria femoralis superficialis KW - arteria poplitea KW - rotational percutaneous mechanical thrombectomy KW - adjunctive endovascular procedures Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217099 ER - TY - JOUR A1 - Steinhardt, Maximilian Johannes A1 - Zhou, Xiang A1 - Krummenast, Franziska A1 - Meckel, Katharina A1 - Nickel, Katharina A1 - Böckle, David A1 - Messerschmidt, Janin A1 - Knorz, Sebastian A1 - Dierks, Alexander A1 - Heidemeier, Anke A1 - Lapa, Constantin A1 - Einsele, Hermann A1 - Rasche, Leo A1 - Kortüm, Klaus Martin T1 - Sequential CD38 monoclonal antibody retreatment leads to deep remission in a patient with relapsed/refractory multiple myeloma JF - International Journal of Immunopathology and Pharmacology N2 - We report on a currently 76-year-old female patient with relapsed/refractory (RR) multiple myeloma (MM) treated at our institution. This patient had received six lines of therapy including tandem autologous stem cell transplant, proteasome inhibitor, immunomodulatory drugs and CD38 antibody MOR202. At the last relapse, she progressed during treatment with pomalidomide and MOR202. In an individualized therapy concept, we started a multi-agent salvage therapy with pomalidomide, bortezomib, doxorubicin, dexamethasone, and CD38 antibody daratumumab (“Pom-PAD-Dara”), which resulted in a stringent complete remission with minimal residual disease (MRD) negativity after nine cycles. So far, our patient shows a progression free survival of more than 12 months. Our case demonstrates the feasibility of successful CD38 antibody retreatment in a patient with heavily pretreated CD38 antibody resistant MM. KW - CD38 KW - MOR202 KW - daratumumab KW - multiple myeloma KW - refractory KW - relapse Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-236235 VL - 34 ER - TY - JOUR A1 - Steinhardt, M. J. A1 - Wiercinska, E. A1 - Pham, M. A1 - Grigoleit, G. U. A1 - Mazzoni, A. A1 - Da-Via, M. A1 - Zhou, X. A1 - Meckel, K. A1 - Nickel, K. A1 - Duell, J. A1 - Krummenast, F. C. A1 - Kraus, S. A1 - Hopkinson, C. A1 - Weissbrich, B. A1 - Müllges, W. A1 - Stoll, G. A1 - Kortüm, K. M. A1 - Einsele, H. A1 - Bonig, H. A1 - Rasche, L. T1 - Progressive multifocal leukoencephalopathy in a patient post allo-HCT successfully treated with JC virus specific donor lymphocytes JF - Journal of Translational Medicine N2 - Background Progressive multifocal leukoencephalopathy is a demyelinating CNS disorder. Reactivation of John Cunningham virus leads to oligodendrocyte infection with lysis and consequent axonal loss due to demyelination. Patients usually present with confusion and seizures. Late diagnosis and lack of adequate therapy options persistently result in permanent impairment of brain functions. Due to profound T cell depletion, impairment of T-cell function and potent immunosuppressive factors, allogeneic hematopoietic cell transplantation recipients are at high risk for JCV reactivation. To date, PML is almost universally fatal when occurring after allo-HCT. Methods To optimize therapy specificity, we enriched JCV specific T-cells out of the donor T-cell repertoire from the HLA-identical, anti-JCV-antibody positive family stem cell donor by unstimulated peripheral apheresis [1]. For this, we selected T cells responsive to five JCV peptide libraries via the Cytokine Capture System technology. It enables the enrichment of JCV specific T cells via identification of stimulus-induced interferon gamma secretion. Results Despite low frequencies of responsive T cells, we succeeded in generating a product containing 20 000 JCV reactive T cells ready for patient infusion. The adoptive cell transfer was performed without complication. Consequently, the clinical course stabilized and the patient slowly went into remission of PML with JCV negative CSF and containment of PML lesion expansion. Conclusion We report for the first time feasibility of generating T cells with possible anti-JCV activity from a seropositive family donor, a variation of virus specific T-cell therapies suitable for the post allo transplant setting. We also present the unusual case for successful treatment of PML after allo-HCT via virus specific T-cell therapy. KW - Myeloma KW - JCV KW - Prodigy KW - CCS KW - PML KW - Donor lymphocytes KW - Adaptive cell transfer Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229307 VL - 18 ER - TY - THES A1 - Steingrüber, Marcus T1 - Die perkutane transluminale Zangenbiopsie biliärer Strikturen: Eine neuartige Methode T1 - The percutaneous endobiliary forceps biopsy of biliary strictures: An innovative technique N2 - Das Ziel der Studie bestand darin, die Durchführbarkeit, Effizienz und Sicherheit der perkutanen transluminalen Zangenbiopsie bei biliären Strikturen nach „Cross and push“ Technik am Universitätsklinikum Würzburg zu evaluieren. Die Gewinnung der Zangenbiopsie bei den insgesamt 17 Patienten erfolgte an den baugleichen Angiographieeinheiten der interventionellen radiologischen Abteilung. Die Schaffung des biliären Zugangsweges wurde per Feinnadelpunktion oder über einen bereits einliegenden Drainagekatheter durchgeführt. Nach Vordirigieren einer armierten Führungsschleuse bis unmittelbar vor die Stenose wurden die Gewebeproben mittels Biopsiezange entnommen. Auf diese Weise sollte ein Abknicken des Instrumentariums durch die fibrotische Beschaffenheit der Striktur vermieden und so die Gewebegewinnung erleichtert werden. Im Anschluss folgten die PTCD-Neuanlage bzw. der Katheterwechsel sowie die histologische Auswertung der Zangenbiopsie. Die Dokumentation umfasste den technischen Erfolg, die Biopsieanzahl sowie -größe, die Untersuchungs- und die Fluoroskopiezeit, das Dosisflächenprodukt, die Repräsentativität der Biopsien und die Komplikationsrate. Die technische Erfolgsrate lag bei 100 %. Bei zehn Patienten und Patientinnen (58,8 %) wurde in der Zangenbiopsie ein Malignom bestätigt. Bei sieben Betroffenen (41,2 %) ergab die Zangenbiopsie einen benignen Befund, wobei dieser in zwei Fällen (11,8 %) falsch negativ war. Die Kriterien der Repräsentativität wurden bei elf Patienten und Patientinnen (64,7 %) erfüllt. Die mediane Biopsiezahl betrug 4 und die Biopsiegröße war 1 - 2 mm. Bei einer medianen Untersuchungszeit von 24 min bemaß sich die mediane Fluoroskopiezeit auf 7,6 min. Das mediane DAP für alle Interventionen betrug 2.593 μGym2. Zu einer Majorkomplikation kam es bei einer Patientin (5,9 %). Bei der perkutanen transluminalen Zangenbiopsie nach „Cross and push“ Technik handelt es sich um ein effektives und sicheres Verfahren zur histologischen Beurteilung biliärer Strikturen mit einer moderaten Komplikationsrate. Die Anwendung sollte besonders bei proximalen Strikturen in Betracht gezogen werden, wenn die ERCP oder alternative Verfahren nicht erfolgreich waren und parallel eine Entlastung der Cholestase via PTCD intendiert oder bereits vorhanden ist. Zur weiteren Evaluation der Methode ist zukünftig die Betrachtung eines größeren Patientenkollektives nötig. Um das Verfahren mit Alternativmethoden vergleichen zu können, bedarf es randomisierter kontrollierter Studien. N2 - Percutaneous transhepatic biliary drainage-based forceps biopsy in patients with biliary obstruction of unknown origin is an relatively unknown procedure. Nonetheless this method offers the opportunity of tissue sampling and therapy of obstructive jaundice via percutaneous transhepatic biliary drainage (PTBD) simultaneously. In 2015 Patel et al. described the percutaneous endobiliary forceps biopsy (PEFB) using “cross and push” technique. This approach is characterized by using a guiding sheath to push and advance the biopsy forceps into the biliary stricture. By supporting the forceps biopsy catheter with a sheath, a retroflexion of the forceps cup leading to an ineffective biopsy can be prevented. Aim of the following study was to evaluate feasibility, efficiency and safety of this procedure in our institution. Between October 2014 and October 2019 17 patients underwent PEFB in the interventional radiology department. Biliary access was achieved by using a percutaneous access needle or via a preexisting external biliary drainage catheter. After obtaining the specimens for histopathologic evaluation, a new biliary drainage catheter was placed. The primary outcome measures were: evaluation of technical success rate, procedure time and fluoroscopy time, dose area product (DAP), complication rate, number and size of the biopsies as well as the histopathologic results. Technical success rate was 100 %. In ten patients PEFB confirmed a malignant biliary stricture. Seven patients had a benign histopathologic result, although in two cases this proofed to be false negative. In eleven patients the tissue samples proofed to be representative for the underlying disease. The median number of biopsies was 4 with a size between 1 -2 mm. The median procedure time was 24 minutes with a median fluoroscopy time of 7,6 minutes. Median DAP was 2.593 μGym2. Complications occurred in three cases with one major complication and minor complications in two patients. The percutaneous endobiliary forceps biopsy is a feasible and safe technique for histologic evaluation of biliary strictures. The procedure should be considered in cases not allowing an endoscopic approach and when the drainage of obstructive jaundice via PTBD is planned or already present. KW - Zangenbiopsie KW - biliäre Striktur KW - biliäre Stenose KW - Gallengangsstenose KW - PEFB Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-321721 ER - TY - THES A1 - Steiner, Martin T1 - Langzeitergebnisse nach radiologischen Interventionen der Becken- und Beinarterien T1 - Long-term results of radiological interventions in the iliacal- and femoropopliteal arteries N2 - Retrospektive Studie (1995-1999) aus dem Institut für Röntgendiagnostik der Universität Würzburg mit insgesamt 206 Patienten. Die Offenheitsraten der insg. 535 radiologischen Interventionen (PTA, Stentimplantationen) der Becken- und Beinarterien wurden in einer statistischen Auswertung nach Kaplan-Meier dargestellt. Dabei wurden die Ergebnisse auf die unterschiedlichen Grundparameter (Alter, Geschlecht, Risikofaktoren, Fontaine-Stadium, Gefäßlokalisation, Runoff, Stenosenart, Stenosenanzahl, Interventionsart...) bezogen. N2 - Retrospective study (1995-1999) with 206 patients at the Institut of radiological diagnostics of the University of Würzburg. The long-term results of 535 radiological interventions (angioplasty, stenting) of the iliacal- and femoropopliteal arteries were represented in a statistic evaluation of Kaplan-Meier. The patency rate was referred of the different basic parameters (age, sex, risc factors, Fontaine-classification, vascular localisation, runoff, stenosis type, stenosis number, kind of intervention...). KW - Langzeitergebnisse KW - Arterien KW - Atherosklerose KW - Interventionen KW - Angioplastie KW - long-term results KW - patency rate KW - atherosclerosis KW - angioplasty KW - stents Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8161 ER - TY - THES A1 - Steffens, Viola Juliane T1 - Endovaskuläre Behandlung intrakranieller Aneurysmen: Therapie und Verlaufsuntersuchungen - eine Single-Center-Studie - T1 - Endovascular treatment of intracranial aneurysms: therapy and follow-up study- a single-center-study- N2 - In den letzten Jahren wird verbreitet das Coiling, die endovaskuläre Technik zur Behandlung von intrakraniellen Aneurysmata genutzt. Hierbei werden mittels eines Mikrokatheters Platinspiralen unter Durchleuchtung in das Aneurysma platziert. Aufgrund dieser minimal invasiven Methode und positiver Ergebnisse in verschiedenen Studien ist es heute eine Alternative zum bisherigen chirurgischen Clipping, das immer mehr in den Hintergrund gedrängt wurde. In der vorliegenden Studie wird die Rate der periinterventionellen Komplikationen (wie Coildislokationen und Gefäßverschlüsse), der Zusammenhang zwischen der Rekanalisation und der Aneurysmagröße, der Packungsdichte, der verwendeten Spiralen, sowie der Lokalisation des Aneurysmas untersucht. Ziel ist es das Verhältnis der Okklusion des Aneurysmas zu den oben genannten Faktoren zu klären. Im retrospektiven Teil der Studie werden Aneurysmen von 198 Patienten und im prospektiven Anteil 100 Patienten mit 101 Aneurysmen eingeschlossen. Im Anschluss werden die Ergebnisse mit ähnlichen oder vergleichbaren Daten der Literatur, wie z. B. die ISAT und deren Folgestudien, diskutiert. Ein direkter Vergleich war nicht möglich, da diese Studien weitaus größere Patientenanzahlen beinhalteten. N2 - Endovascular treatment of intracranial aneurysms: therapy and follow-up study- a single-center-study- KW - Intrakranielles Aneurysma KW - Aneurysmen KW - intrakraniell KW - endovaskulär KW - aneurysms KW - intracranial KW - endovascular Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-74839 ER - TY - THES A1 - Stamm, Heimo Helmut T1 - Parallele Echtzeitbildgebung zur Quantifizierung der linksventrikulären Herzfunktion bei freier Atmung mittels MRT T1 - Cardiac functional parameters determined under free breathing by untriggered real-time MR acquisition N2 - MRT-Untersuchungen des Herzens haben in den letzten Jahren an Häufigkeit und Bedeutung zugenommen. Die Nachfrage nach schnelleren und für den Patienten komfortableren Sequenzen steigt. Diese Arbeit untersucht, ob es mit Hilfe von parallelen Echtzeitsequenzen ohne EKG-Triggerung möglich ist, die Untersuchungszeit deutlich zu verkürzen und dabei gut reproduzierbare Messwerte zu erhalten. Hierzu wurden 9 Probanden und 21 Patienten mit A) paralleler Echtzeitbildgebung bei freier Atmung und B)einer Standard CINE Sequenz mit Atemstopp untersucht. Zur statistischen Analyse beider Methoden dienten Bland-Altman-Plots. Um Aussagen über die Reproduzierbarkeit der Ergebnisse treffen zu können wurde außerdem die Variabilität der Messungen bestimmt. Die Messzeit der neuen Echtzeitsequenz war um mehr als das zehnfache kürzer als die einer herkömmlichen CINE Sequenz. Die Ergebnisse waren mit der Standard CINE Sequenz vergleichbar und zeigten nur einen geringe Variabilität. Lediglich die linksventrikuläre Masse wurde im Gesamtkollektiv leicht überschätzt. Insgesamt scheint die Echtzeitbildgebung aufgrund der zuverlässigen Ergebnisse für den Klinikalltag geeignet. Insbesondere Patienten mit Atemnot, Herzrhythmusstörungen oder aber Kinder könnten profitieren. N2 - The increasing frequency of LV functional MRI studies demands for faster methods and for more comfort for the patient. The purpose of this work was to assess whether real-time (RT) non ECG triggered MRI allows a considerable shortening of examination time in high reproducibility. RT and standard ECG-triggered breathhold cine MRI was acquired in 9 volunteers and 21 patients. Differences between both methods were assessed by Bland-Altman analyses including variability studies. Compared to standard cine MRI, RT decreased data acquisition time by more than the factor of ten. RT produced comparable results except for a slight overestimation of LV mass. Interstudy and intraobserver variability of RT cine showed a low variability. Consequently, free-breathing RT cine proved to be a reliable and suitable tool for clinical routine and may be particularly relevant in patients with sub-optimal breath-holding ability, arrhythmia or childern. KW - MRT KW - Echtzeit KW - CINE KW - Herz KW - Atmung KW - MRT KW - Echtzeit KW - CINE KW - Herz KW - Atmung KW - real-time KW - CINE KW - MRI KW - cardiac breathing Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-47900 ER - TY - THES A1 - Seyfarth, Tobias T1 - Quantitative MR-Spektroskopie des menschlichen Herzens mittles SLOOP N2 - Die Zielsetzung dieser Arbeit ist, die Möglichkeiten der Magnetresonanz Spektroskopie zur nichtinvasiven Diagnostik des Myokardstoffwechsels bei globalen Herzkrankheiten unter Verwendung neuer Möglichkeiten der Absolutquantifizierung von hochenergetischen Phosphaten zu beschreiben. Im Vordergrund dieser Arbeit stehen folgende Punkte: 1. Etablierung einer Methode zur Absolutquantifizierung von Metabolitenkonzentrationen aus dem menschlichen Myokard und Festlegung eines standardisierten Untersuchungsprotokolls 2. Überprüfung der Methode auf Variabilitäten durch Mehrfachauswertungen und Verlaufsuntersuchungen 3. Untersuchung der Altersabhängigkeit der Metabolitenkonzentrationen 4. Einsatz der Methode an Patienten mit globalen Herzerkrankungen; Herausstellung der metabolischen Unterschiede bei Hypertrophie und Dilatation. N2 - To describe the opportunities of Magnetic Resonance Spectroscopy to measure non-invasisvly the myocardial metabolism in global heart diseases are the objectives of these study. New possibilities of absolut quantification of high energy phosphates are used with respect given to following main aspects: 1. Setup of a technique for absolut quantification of metabolic concentrations of the human myocardial tissue and arranging a standard examination protocol. 2. Verification of the technique for variabilities by use of multievaluations and follow up utilization. 3. Examniation of age dependence of metabolic concentrations 4. Use of the technique by patients with global heart diseases; emphasize the metabolic differences between hypertrophy and dilatation. KW - MR-Spektroskopie KW - SLOOP KW - ATP KW - MR-Spectroscopie KW - SLOOP KW - ATP Y1 - 2001 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-1182658 ER - TY - JOUR A1 - Seefried, Lothar A1 - Genest, Franca A1 - Baumann, Jasmin A1 - Heidemeier, Anke A1 - Meffert, Rainer A1 - Jakob, Franz T1 - Efficacy of Zoledronic Acid in the Treatment of Nonmalignant Painful Bone Marrow Lesions: A Triple‐Blind, Randomized, Placebo‐Controlled Phase III Clinical Trial (ZoMARS) JF - Journal of Bone and Mineral Research N2 - Bone marrow lesions (BML) represent areas of deteriorated bone structure and metabolism characterized by pronounced water‐equivalent signaling within the trabecular bone on magnetic resonance imaging (MRI). BML are associated with repair mechanisms subsequent to various clinical conditions associated with inflammatory and non‐inflammatory injury to the bone. There is no approved treatment for this condition. Bisphosphonates are known to improve bone stability in osteoporosis and other bone disorders and have been used off‐label to treat BML. A randomized, triple‐blind, placebo‐controlled phase III trial was conducted to assess efficacy and safety of single‐dose zoledronic acid (ZOL) 5 mg iv with vitamin D 1000 IU/d as opposed to placebo with vitamin D 1000 IU/d in 48 patients (randomized 2:1) with BML. Primary efficacy endpoint was reduction of edema volume 6 weeks after treatment as assessed by MRI. After treatment, mean BML volume decreased by 64.53% (±41.92%) in patients receiving zoledronic acid and increased by 14.43% (±150.46%) in the placebo group (p = 0.007). A decrease in BML volume was observed in 76.5% of patients receiving ZOL and in 50% of the patients receiving placebo. Pain level (visual analogue scale [VAS]) and all categories of the pain disability index (PDI) improved with ZOL versus placebo after 6 weeks but reconciled after 6 additional weeks of follow‐up. Six serious adverse events occurred in 5 patients, none of which were classified as related to the study drug. No cases of osteonecrosis or fractures occurred. Therefore, single‐dose zoledronic acid 5 mg iv together with vitamin D may enhance resolution of bone marrow lesions over 6 weeks along with reduction of pain compared with vitamin D supplementation only. KW - bone biology KW - osteoporosis KW - bone marrow lesion/edema KW - bisphosphonates KW - zoledronic acid Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-276368 VL - 37 IS - 3 SP - 420 EP - 427 ER - TY - THES A1 - Schweingel, Anne-Kathrin T1 - Die Anfänge der Radiologie in der Kinderheilkunde und ihre Bedeutung für die Entwicklung zur eigenen klinischen Disziplin. T1 - The beginning of radiology in paediatrics and the importance for its development to a separate clinical discipline N2 - Die Arbeit befasst sich mit der Frage, welche Bedeutung die Radiologie in ihrer Anfangszeit (1895-1912) für die Verselbstständigung der Kinderheilkunde zur eigenen klinischen Disziplin hatte. Sie verdeutlicht dies anhand ausgewählter Krankheitsbilder bei denen die Radiologie neue Erkenntnisse erbrachte, eine frühere und beweiskräftigere Diagnose ermöglichte, eine effektivere Therapie zuließ oder auch ein verstärktes Interesse an den medizinischen Besonderheiten des Kindesalters weckte. In diesem Zusammenhang werden auch Ergebnisse der entsprechenden Grundlagenforschung dargestellt, wie zum Beispiel die Ossifikationsstudien. Insgesamt werden, basierend auf konkreten Beispielen, Zusammenhänge zwischen radiologischer Forschung und der Forderung nach Verselbstständigung der Kinderheilkunde als eigenständige Disziplin hergestellt. N2 - The doctoral looks into the question to what extent the Radiology in the beginning (1895-1912) influenced the paediatrics to become a separate clinical discipline. The thesis of this doctoral is elucidated by selected examples of syndromes showing how the recent technology of radiology caused new knowledge, gave the possibility of an earlier and better diagnostics, enabled to a more effective therapy and increased the interest in characteristic medical features of childhood. In this context various results of the pure research are explained, for example studies of ossification. Mainly, the doctoral clarifies, based on various examples correlations between the advances of the radiological research and the demand for paediatrics to become a separate clinical discipline. KW - Radiologie KW - Kinderheilkunde KW - Pädiatrie KW - radiology KW - paediatrics Y1 - 2002 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-6686 ER - TY - THES A1 - Schubert, Katrin T1 - 31-P-Magnetresonanztomographie der menschlichen Leber T1 - 31-P-MR-Spectroskopie of the Human Liver N2 - Die 31-P-Magnetresonanz-Spektroskopie (31-P-MRS) ist eine nicht-invasive Methode, welche einen direkten Einblick in den Phospholipid-Haushalt der menschlichen Leber erlaubt. Mit der 31-P-MR-Spektroskopie wurden Spektren von 10 Patienten mit Leberzirrhose sowie von 13 gesunden Probanden in Kombination mit dem Lokalisationsverfahren 3D-CSI und dem Nachbearbeitungsprogramm SLOOP (Spectral Localization with Optimal Pointspread Funktion) gewonnen. Die Ergebnisse dieser Studie ergaben signifikante Unterschiede in den Absolutkonzentrationen der Phospholipide zwischen Patienten mit Leberzirrhose und lebergesunden Probanden. N2 - Phosphorus-31 magnetic resonance spectroskopie (31-P-MRS) is a noninvasive technique that permits direct assessments of phospholipid metabolism of human liver. 31-P-MR spectroscopy was performed in 10 patients with cirrhosis and in 13 normal controls in combination with a 3D-CSI technique and the postprocessing program SLOOP (Spectral Localization with Optimal Pointspread Funktion). Results show a significant difference in absolute concentration of phospholipids in patients with cirrhosis and normal controls. KW - 31-P-Magnetresonanztomographie KW - Leber KW - Leberzirrhose KW - 3D-CSI KW - AMARES KW - SLOOP KW - Absolutkonzentrationen KW - 31-P-MR-Spectroskopie KW - liver KW - cirrhosis KW - 3D-CSI KW - AMARES KW - SLOOP KW - absolute metabolite concentrations Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-19613 ER - TY - JOUR A1 - Schreiber, Laura M. A1 - Lohr, David A1 - Baltes, Steffen A1 - Vogel, Ulrich A1 - Elabyad, Ibrahim A. A1 - Bille, Maya A1 - Reiter, Theresa A1 - Kosmala, Aleksander A1 - Gassenmaier, Tobias A1 - Stefanescu, Maria R. A1 - Kollmann, Alena A1 - Aures, Julia A1 - Schnitter, Florian A1 - Pali, Mihaela A1 - Ueda, Yuichiro A1 - Williams, Tatiana A1 - Christa, Martin A1 - Hofmann, Ulrich A1 - Bauer, Wolfgang A1 - Gerull, Brenda A1 - Zernecke, Alma A1 - Ergün, Süleyman A1 - Terekhov, Maxim T1 - Ultra-high field cardiac MRI in large animals and humans for translational cardiovascular research JF - Frontiers in Cardiovascular Medicine N2 - A key step in translational cardiovascular research is the use of large animal models to better understand normal and abnormal physiology, to test drugs or interventions, or to perform studies which would be considered unethical in human subjects. Ultrahigh field magnetic resonance imaging (UHF-MRI) at 7 T field strength is becoming increasingly available for imaging of the heart and, when compared to clinically established field strengths, promises better image quality and image information content, more precise functional analysis, potentially new image contrasts, and as all in-vivo imaging techniques, a reduction of the number of animals per study because of the possibility to scan every animal repeatedly. We present here a solution to the dual use problem of whole-body UHF-MRI systems, which are typically installed in clinical environments, to both UHF-MRI in large animals and humans. Moreover, we provide evidence that in such a research infrastructure UHF-MRI, and ideally combined with a standard small-bore UHF-MRI system, can contribute to a variety of spatial scales in translational cardiovascular research: from cardiac organoids, Zebra fish and rodent hearts to large animal models such as pigs and humans. We present pilot data from serial CINE, late gadolinium enhancement, and susceptibility weighted UHF-MRI in a myocardial infarction model over eight weeks. In 14 pigs which were delivered from a breeding facility in a national SARS-CoV-2 hotspot, we found no infection in the incoming pigs. Human scanning using CINE and phase contrast flow measurements provided good image quality of the left and right ventricle. Agreement of functional analysis between CINE and phase contrast MRI was excellent. MRI in arrested hearts or excised vascular tissue for MRI-based histologic imaging, structural imaging of myofiber and vascular smooth muscle cell architecture using high-resolution diffusion tensor imaging, and UHF-MRI for monitoring free radicals as a surrogate for MRI of reactive oxygen species in studies of oxidative stress are demonstrated. We conclude that UHF-MRI has the potential to become an important precision imaging modality in translational cardiovascular research. KW - ultrahigh-field MRI KW - large animal models KW - translational research KW - research infrastructure KW - heart KW - organoid KW - pig KW - cardiovascular MRI Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-317398 SN - 2297-055X VL - 10 ER - TY - THES A1 - Schreiber, Fabienne T1 - Kontrastverstärkte sonographische Diagnostik des vesikoureteralen Refluxes mit Einsatz von einer 2. Generation US-Kontrastmittel [SonoVue®] im Vergleich zur Röntgen-Miktionszystourethrographie T1 - Contrast-enhanced sonographic diagnosis of vesicoureteric reflux using a 2nd generation US contrast agent in comparison with the voiding cystourethrography N2 - ZIEL: Die Miktionsurosonographie (MUS) entwickelte sich zu einer alternativen Untersuchungsmethode gegenüber der Miktionszystourethrographie (MCU) in der Diagnostik des vesikoureteralen Refluxes (VUR). Neuentwickelte stabile US-Kontrastmittel führen zu einer Dosis- und Kostenreduktion der MUS, Harmonic Imaging erhöht die Stabilität der US-Kontrastmittel. Diese Studie vergleicht die kontrastverstärkte sonographische Diagnostik des VUR unter Einsatz eines US-Kontrastmittels der 2. Generation [SonoVue®] mit der MCU. Zudem erfolgt ein Vergleich der Ultraschallmodalitäten Fundamental (F), Tissue Harmonic Imaging (THI) und Echo Contrast Imaging (ECI) bezüglich der Darstellbarkeit der Mikrobläschen des US-Kontrastmittels. MATERIAL und METHODEN: Es wurden 40 Patienten mit insgesamt 84 Nieren-Ureter-Einheiten (NUE) untersucht. Zunächst wurde die MUS und anschließend die MCU durchgeführt. Bei der MUS wurde zwischen den 3 Ultraschallmodalitäten F, THI und ECI gewechselt. Der mechanische Index (MI) wurde automatisch jeder Ultraschallmodalität angepasst. Als US-Kontrastmittel wurde SonoVue® eingesetzt, die Dosis betrug 1% des Blasenfüllungsvolumens. MUS und MCU wurden hinsichtlich der Detektionsrate des VUR verglichen. Beim Vergleich von F, THI und ECI wurden ein Ranking und ein Scoring durchgeführt. ERGEBNISSE: Es lag bei 11 Patienten in beiden Untersuchungen ein VUR vor, bei jeweils 3 Patienten konnte nur in einer der beiden Methoden ein Reflux diagnostiziert werden. Beim Vergleich der MUS mit der Standardmethode MCU zeigten sich eine Sensitivität von 85%, eine Spezifität von 92,2%, ein positiver Vorhersagewert (PVW) von 77,3% und ein negativer Vorhersagewert (NVW) von 95,2%. Beim Vergleich von F, THI und ECI zeigte sich ein signifikanter Vorteil von ECI gegenüber F, nicht aber gegenüber THI. Zwischen THI und F gab es keinen signifikanten Unterschied in der Darstellung der Mikrobläschen. SCHLUSSFOLGERUNG: Der Einsatz eines US-Kontrastmittels der 2. Generation (SonoVue®) in der MUS erzielt vergleichbare Ergebnisse in der Diagnostik des VUR wie die MCU. Die Dosisreduktion (1% des Blasenfüllungsvolumens) könnte zu einer Verringerung der Kosten einer MUS führen. Das Harmonic Imaging ermöglicht eine bessere Darstellung der Mikrobläschen im Vergleich zur fundamentalen Bildgebung. N2 - PURPOSE: In diagnosis of vesicoureteric reflux (VUR), voiding urosonography (VUS) has become an alternative examination method to voiding cystourethrography (VCUG). However, US contrast agents are expensive and therefore the costs of a VUS are higher compared to VCUG. A reduction of the contrast agent dose and thus of the costs of a VUS should be achieved with the development of stable US contrast agents. Stability of the US contrast agents could be increased by introducing harmonic imaging. The aim of this study is the comparison of the contrast enhanced diagnosis of VUR using a 2nd generation US contrast agent [SonoVue®] with VCUG. Furthermore, the US modalities fundamental (F), tissue harmonic imaging (THI) and echo contrast imaging (ECI) are compared considering the visualization of the microbubbles of the US contrast agent. MATERIALS and METHODS: 40 patients have been examined for VUR, the number of kidney ureter units (KUU) was 84. All patients underwent VUS first, directly afterwards VCUG was performed. During VUS it was possible for the examiner to change between the three US modalities F, THI and ECI. The mechanical index (MI) was adapted to every US modality automatically. SonoVue® was used as US contrast agent, the dose being used amounted to 1% of the bladder filling volume. For the VCUG the contrast agent Imeron® was used. The evaluation of the results was carried out by using the statistical program SPSS 10.0.7. The two examination methods VUS and VCUG were compared concerning the detection of VUR. In addition, a ranking was used for the comparison of F, THI and ECI. RESULTS: A VUR was found in 11 patients in both examinations. In three patients each, only one of the examination methods could identify a VUR. Comparing the MUS with the standard method VCUG, the sensitivity was 85%, the specifity 92.2%, the positive predictive value (PPV) 77.3% and the negative predictive value (NPV) 95.2%. The Kappa value (0.746) was significant (p<0.001). No significant difference (p=0.114) could be found when examining whether one of both methods tended to rating basically higher reflux grades. There was a significant advantage of ECI versus F in the comparison of F ,THI and ECI, but not of ECI versus THI. No significant difference was found between THI and F considering the visualization of the microbubbles. CONCLUSION: In the diagnosis of VUR, comparable results to the VCUG can be achieved with VUS when using a 2nd generation US contrast agent (SonoVue®). By reducing the contrast agent dose (1% of the bladder volume) the costs of a VUS could be minimized. Harmonic imaging (THI, ECI) enables a better visualisation of the microbubbles in comparison to the fundamental imaging. KW - VUR KW - MUS KW - MCU KW - Harmonic Imaging KW - SonoVue KW - VUR KW - VUS KW - VCUG KW - Harmonic Imaging KW - SonoVue Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-23583 ER - TY - THES A1 - Schneider, Sebastian T1 - Karpale Bandverletzungen - Vergleich der direkten MR-Arthrographie mit der diagnostischen Arthroskopie unter Berücksichtigung von Partialdefekten des skapholunären Bandes, des lunatotriquetralen Bandes sowie des TFCC T1 - Direct MR Arthrography of the wrist – Value in Detecting Complete and Partial Defects of intrinsic Ligaments and the TFCC in Comparison with Arthroscopy N2 - Evaluation von Defekten des triangulären fibrokartilaginären Komplexes (TFCC) und der intrinsischen Bänder des Handgelenkes mit der direkten MR-Arthrographie im Vergleich zur diagnostischen Arthroskopie unter besonderer Berücksichtigung von Partialdefekten. Material und Methoden: 75 direkte MR-Arthrographien des Handgelenkes (intraartikuläre Injektion eines Gemisches aus Gadoliniumchelaten und Iotrolan) wurden von zwei erfahrenen Radiologen im Konsens ausgewertet. Es wurden T1-gewichtete Spin-Echo(SE)-Sequenzen in frontaler und sagittaler sowie Fast low angle shot (FLASH) 3D-Sequenzen in frontaler Schichtung akquiriert. Läsionen des skapholunären Bandes wurden entsprechend den Leitlinien der Deutschen Gesellschaft für Handchirurgie (DGH), Läsionen des lunatotriquetralen Bandes nach Hempfling, Läsionen des TFCC nach Palmer eingeteilt. Anschließend wurden die Befunde mit der Arthroskopie als Referenzstandard korreliert. Ergebnisse: Für die Verletzungen der intrinsischen Bänder und des TFCC waren die Sensitivitäten und Spezifitäten für Komplettrupturen 96% und 99,6% (T1-SE) bzw. 92% und 100% (FLASH 3D), für Partialdefekte 68,1% und 93,3% (T1-SE) bzw. 63% und 96,1% (FLASH 3D). Die T1-SE-Sequenz eignete sich für die Einschätzung skapholunärer Banddefekte besser als die FLASH 3D-Sequenz (p < 0,05). Für Partialdefekte das skapholunären Bandes wurde mit der T1-SE-Sequenz eine Sensitivität von 83,3%, mit der FLASH 3D-Sequenz von 64,7% erreicht. Schlussfolgerung: Die direkte MR-Arthrographie ist bei der Einschätzung von Komplettrupturen der intrinsischen Bänder und des TFCC der diagnostischen Arthroskopie gleichwertig. Mit der T1-SE-Sequenz sind Partialdefekte des skapholunären Bandes im Vergleich zur Arthroskopie mit ausreichender Sicherheit erkennbar. Die T1-SE-Sequenz war hierfür der FLASH 3D-Sequenz überlegen (p < 0,05) und sollte bei der Einschätzung skapholunärer Partialdefekte bevorzugt werden. Die Einschätzung des lunatotriquetralen Bandes gelingt nicht zuverlässig. N2 - To assess the value of two-compartment magnetic resonance (MR) wrist arthrography in comparison with arthroscopy for the evaluation of defects of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments in patients with refractory wrist pain. The direct MR arthrographics were evaluated following arthroscopy classification with consideration of complete and partial defects. The distinction between these types of lesions has clinical implications for treatment procedures such as cast immobilization, arthroscopic debridement, surgical repair or partial intercarpal arthrodesis. Materials and Methods: Seventy-five patients (25 female, 50 males, mean age 38.3 years) who suffered from refractory wrist pain without radiography evidence of carpal instability underwent two-compartment wrist MR arthrography. Under aseptic conditions a solution of gadopentate dimeglumine and iodinated contrast agent (concentration 2.5mmol/l) was injected into the radiocarpal and midcarpal joints under fluorscopy guidance. Using a scanner of 1.5T field strength and a wrist-coil following sequences were acquired: coronary and sagittal T1-weighted spin-echo (SE) sequences (TR 500ms, TE 25ms, matrix 512*512, 3mm) and coronary fast low angle shot (FLASH) 3D sequences (TR 24ms, TE 11ms, matrix 256*256, 1.5mm, flip angle 50 degrees). All patients underwent subsequent arthroscopy of the wrist. The direct MR arthrographies were evaluated retrospectively by two observers experienced in the diagnosis of wrist pathology. They were not aware of the clinical, arthrographic and arthroscopic findings. Pathology of the scapholunate ligament was classified according to the guidelines of the German Society of Hand Surgery (DGH), lesions of the lunotriquetral ligament according to Hempfling and lesions of the TFCC according to Palmer. Results: Twenty-five complete and 47 partial defects were detected arthroscopically (TFCC: 21/20, scapholunate ligament: 3/18, lunotriquetral ligament: 1/9). The TFCC showed a higher prevalence for degenerative lesions (11 type 2C-lesions and 20 type 2A/B-lesions) than for traumatic lesions (5 type 1A-lesions, 5 type 1D-lesions). For direct MR arthrography , the obtained sensitivities and specificities in assessing complete defects were 96% and 99.6% (T1-weigthed SE) and 92% and 100% (FLASH 3D), respectively. For all partial defects, sensitivities and specificities were 68.1% and 93.3% (T1-weigthed SE) and 63% and 96.1% (FLASH 3D), respectively. For depicting partial defects of the scapholunate ligament the T1-weigthed SE sequence (83.3/95.5%) was superior to the FLASH 3D sequence (64.7/96.6%), p < 00.5. For the evaluation of the TFCC (T1-weigthed SE: 65/94.4%, FLASH 3D: 70/94.6%) and the lunotriquetral ligament (T1-weigthed SE: 44/89.4%, FLASH 3D: 44/96.7%), direct MR arthrography showed an insufficient correlation with arthroscopy. Conclusion: Direct MR arthrography proved to be of equal value compared with diagnostic arthroscopy in detecting complete defects of the intrinsic ligaments and the TFCC. The method has the potential of replacing diagnostic arthroscopy for the evaluation of the intrinsic ligaments and the TFCC. The T1-weigthed SE sequence appeared to be superior to the FLASH 3D sequence in evaluating partial defects of the scapholunate ligament. Direct MR arthrography did not reliably detect partial defects of the TFCC and the lunotriquetral ligament. KW - MRT KW - Arthroskopie KW - MR-Arthrographie KW - Hand KW - Bänder KW - TFCC KW - MRI KW - arthroscopy KW - MR arthrography KW - wrist KW - ligaments KW - TFCC Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-7970 ER - TY - THES A1 - Schmid, Gordian Georg T1 - T1-Mapping zur frühen Detektion fibrotischer Veränderungen bei Anderson-Fabry-Patienten T1 - T1-Mapping for early detection of myocardial fibrosis in Anderson-Fabry disease N2 - Bei Patienten mit Morbus Fabry spielt die kardiale MRT eine wesentliche Rolle für die Diagnostik, die Prognose und das Therapiemonitoring. Als Verfahren der Wahl zur Beurteilung einer fokalen myokardialen Fibrose hat sich das Late Gadolinium Enhancement (LGE) etabliert. Eine diffuse myokardiale Fibrosierung kann mittels LGE-Technik nicht suffizient abgebildet werden, da keine ausreichenden Unterschiede in der Signalintensität bestehen. Daher könnte das sog. post-KM T1-Mapping eine interessante Alternative sein. Bei diesem Verfahren lassen die T1-Relaxationszeiten Rückschlüsse auf diffuse fibrotische Veränderungen des Myokards zu. In der vorliegenden Arbeit wurden 43 Fabry-Patienten (20 LGE-positiv und 23 LGE-negativ) im MRT untersucht. Hierzu wurde eine modifizierte Look-Locker Inversion-Recovery (MOLLI)-Sequenz zur Messung der T1-Maps verwendet. Ziel war es, durch das T1-Mapping Risikopatienten (u.a. LGE-negative Patienten) früher als bisher zu identifizieren und damit zeitnah einer entsprechenden Therapie zuzuführen. Die Ergebnisse zeigten, dass LGE-positive Fabry-Patienten eine fortgeschrittenere diffuse Myokardfibrose im visuell gesunden Myokard aufweisen als LGE-negative Patienten. Eine Unterscheidung anhand der T1-Zeiten zwischen LGE-negativen Patienten und gesunden Probanden war nicht möglich. Somit kann das T1-Mapping nicht als diagnostische Methode zur Früherkennung einer diffusen Myokardfibrose bei Fabry-Patienten eingesetzt werden. Des Weiteren konnte gezeigt werden, dass die T1-Zeit im linksventrikulären Myokard bei Fabry-Patienten mit eingeschränkter Nierenfunktion kürzer war als bei Patienten mit normaler Nierenfunktion, unabhängig vom Vorliegen einer fokalen Fibrose. Hingegen konnte im linksventrikulären Blut bei abnehmender glomerulärer Filtrationsrate (GFR) keine kürzere T1-Zeit festgestellt werden als bei normaler GFR. Außerdem waren die T1-Relaxationszeiten bei LGE-negativen, weiblichen Fabry-Patienten kürzer als bei männlichen Patienten ohne LGE. Eine abschließende Erklärung konnte hierfür nicht gefunden werden. T1-Mapping wird bislang noch nicht in der Routinediagnostik bei Morbus Fabry eingesetzt. Allerdings steigt dessen Bedeutung im Rahmen von Studien. Weitere Forschungsbemühungen sind notwendig, um geeignete Referenzwerte festzulegen und den Einfluss weiterer Faktoren auf die Fibrosierung des Myokards besser einschätzen zu können. N2 - The aim of this study was to investigate whether T1-Mapping is a valid technique for non-invasive detection of diffuse myocardial fibrosis in patients with Anderson-Fabry disease (AFD). The Late Gadolinium Enhancement (LGE) technique is the gold standard in detection of focal myocardial scar. T1-Mapping is sought to be able to detect diffuse myocardial changes, which are precursors of focal scar in AFD. In the current study 43 AFD patients (20 LGE-positive and 23 LGE-negative patients) and 27 healthy volunteers were examined by MRI. A modified Look-Locker Inversion-Recovery (MOLLI)-sequence was used for the acquisition of the T1-Maps. The conception was to use T1-Mapping as an early diagnosis tool to distinguish LGE-negative AFD patients from healthy volunteers. The results indicated that AFD patients with focal scar (LGE-positive) had an advanced diffuse fibrosis in the visually healthy myocardium compared with AFD patients without focal scar. A differentiation between LGE-negative AFD patients and healthy volunteers on the basis of T1-Maps was not able. So T1-Mapping cannot be used as a diagnostic device for early detection of diffuse fibrotic changes in the myocardium in AFD. It has been shown that T1 in the left ventricular myocardium of AFD patients with renal failure is shorter than in patients with normal renal function, independent of focal inferolateral scar, but there was no difference in T1 in the left ventricular blood. Furthermore, female AFD patients without focal scar had shorter T1 than male patients. No clear explanation was found for shorter T1 in LGE-negative female AFD patients. T1-Mapping is a useful, objective and convincing method for examining of diffuse myocardial fibrosis. Pre- and postcontrast T1-Mapping should be performed in further studies for a more detailed investigation of alterations of the myocardium in AFD. The analysis of T1-Maps must be simplified for routine administration in AFD and the acquisition protocols should be standardized (including pulse sequence, contrast agent, dose of the agent). So, a more detailed examination of the myocardium can be performed than by using LGE. KW - Fabry-Krankheit KW - T1-Mapping KW - Myokardfibrose Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177601 ER - TY - JOUR A1 - Schmid, Andrea A1 - Lois, Anna-Maria A1 - Metz, Corona A1 - Grunz, Jan-Peter A1 - Veldhoen, Simon T1 - Not all that looks fractured is broken - multipartite humeral epicondyles in children JF - European Radiology N2 - Objective Multipartite epicondyles may mimic fractures in the setting of pediatric elbow trauma. This study examines the prevalence of multipartite epicondyles during skeletal development and their association with pediatric elbow fractures. Materials and methods In this retrospective analysis, 4282 elbow radiographs of 1265 elbows of 1210 patients aged 0–17 years were reviewed. The radiographs were analyzed by two radiologists in consensus reading, and the number of visible portions of the medial and lateral epicondyles was noted. For elbows in which epicondylar ossification was not yet visible, the epicondyles were already fused with the humerus or could not be sufficiently evaluated due to projection issues or because osteosynthesis material was excluded. In total, 187 elbows were included for the lateral and 715 for the medial epicondyle analyses. Results No multipartite medial epicondyles were found in patients without history of elbow fracture, whereas 9% of these patients had multipartite lateral epicondyles (p < 0.01). Current or previous elbow fractures increased the prevalence of multipartite epicondyles, with significant lateral predominance (medial epicondyle + 9% vs. lateral + 24%, p < 0.0001). Including all patients regardless of a history of elbow fracture, multipartite medial epicondyles were observed in 3% and multipartite lateral epicondyles in 18% (p < 0.0001). There was no gender difference in the prevalence of multipartition of either epicondyle, regardless of a trauma history. Conclusion Multipartite medial epicondyles occur in patients with current or previous elbow fractures only, whereas multipartite lateral epicondyles may be constitutional. Elbow fractures increase the prevalence of multipartite epicondyles on both sides, with significant lateral predominance. Key Points • Multipartite medial epicondyles should be considered of traumatic origin. • Multipartite lateral epicondyles may be constitutional. • Elbow fractures increase the prevalence of multipartite epicondyles on both sides with lateral predominance. KW - elbow joint KW - epicondyles KW - bone fractures KW - pediatrics KW - radiography Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324987 VL - 32 IS - 8 ER - TY - THES A1 - Schmid, Andrea T1 - Diagnostische Genauigkeit der Dual-Energy Computertomographie Angiographie bei Patienten mit peripherer arterieller Verschlusskrankheit T1 - Diagnostic Accuracy of Dual-Energy Computertomography Angiography in Patients with Peripheral Arterial Occlusive Disease N2 - Es wurde die diagnostische Genauigkeit fünf verschiedener Rekonstruktionsalgorithmen der DE-CTA der Becken-Bein-Gefäße von Patienten mit pAVK an einem Dual-Source CT mit dem diagnostischen Goldstandard der DSA verglichen. Die DE-CTA zeigte eine exzellente Sensitivität an Becken- und Beingefäßen hinsichtlich einer korrekten Stenosegraduierung, unabhängig von der Rekonstruktion. Die Standard MPR zeigte insgesamt die besten Ergebnisse und ist deshalb vor allem in nicht eindeutigen Fällen die Methode der Wahl. Die Auswertung von DE-CS MPRs, DE-CS MIPs, gekrümmten MPRs oder die semi-automatische quantitative Stenosegradauswertung bringt keinen Zugewinn an diagnostischer Performance im Vergleich zur visuellen Auswertung der Standard MPR. Das Ausmaß der Gefäßwandverkalkungen und die intraluminale Kontrastierung hatten keinen signifikanten Effekt auf die Sensitivität zur Erkennung signifikanter Stenosen an den Becken- und Beingefäßen. Jedoch verschlechterten sich die Spezifität und die Genauigkeit der Rekonstruktionen, welche auf der DE-Knochen- und DE-Plaqueentfernung basieren, signifikant in stark verkalkten oder nur schwach kontrastierten Gefäßsegmenten. Beim Auswerten von DE-CS Rekonstruktionen ist infolgedessen vor allem in schlecht kontrastierten oder stark verkalkten Gefäßen eine weitere Verifizierung des Befundes nötig, um unnötige invasive DSAs als Folge von falsch positiven CTA-Befunden zu reduzieren. N2 - The diagnostic accuracy of five different DE-CTA recontruction approaches of a dual-source CT in patients with peripheral artery disease were compared, using digital subtraction angiography as reference standard. DE-CTA shows an excellent sensitivity for the detection of lower extremity arterial stenosis, regardless of image reconstruction approach. The standard MPR showed the best results overall and is therefore the method of choice in unclear cases. Thus DE-CS MPRs, DE-CS MIPs, curved MPRs and semi-automatic stenosis grading don’t bring additional value regarding the diagnostic performance in comparison to the standard MPR. The amount of vessel wall calcification and the intraluminal contrast had no significant effect on the sensitivity for the detection of lower extremity arterial stenosis. Specifity and accuracy decreased in reconstructions that relied on DE-bone- and DE-plaque-subtraction significantly in vessels with strong calcification or poor contrasting. When analyzing DE-CS reconstructions for poorly contrasted or strongly calcified vessels a further evaluation is necessary, to avoid invasive DSAs as a result of false positive findings. KW - Dual-Source-Computertomographie KW - Periphere arterielle Verschlusskrankheit KW - Computertomographie Angiographie KW - Dual-Source Computertomography KW - Peripheral Artery Disease KW - Computertomography Angiography Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-251137 ER - TY - THES A1 - Schlauß, Britta T1 - Darmsonographie bei Kindern - Vergleich von fundamentaler und harmonischer Bildgebung T1 - Bowel Sonography in Children – Comparison between fundamental and harmonic imaging N2 - Darmsonographie bei Kindern – Vergleich von fundamentaler und harmonischer Bildgebung. Ziel: Die harmonische Bildgebung (Harmonic Imaging, HI) wurde eingeführt, um für übergewichtige Erwachsene die Ultraschall-Untersuchung zu verbessern. Inwiefern sie auch für Kinder von Vorteil ist, die aufgrund ihrer physikalischen Eigenschaften bessere Untersuchungsbedingungen als Erwachsene bieten, ist bisher nur wenig untersucht worden. Die vorliegende Arbeit beschäftigt sich mit der Frage, ob mit HI bei der Darmsonographie von Kindern eine Verbesserung gegenüber Fundamental Imaging (FI) eintritt. Material und Methode: Bei 90 Kindern (w:m=46:44) wurden mit einem linearen 7,5MHz- Schallkopf jeweils vier Bildpaare des Darms in fundamentaler und harmonischer Bildgebung (THI- Sonoline Elegra®, Siemens) angefertigt. Die Bilder wurden anhand einer zehnstufigen Skala evaluiert. Zudem wurde der Einfluss von Alter, Geschlecht und BMI-FAP auf die Darstellbarkeit des Darms untersucht und darauf geachtet, ob Darmpathologien wie Wandverdickung und Dilatation vorliegen. Ergebnisse: Bei 17 Patienten wurde jeweils ein Bildpaar ausgeschlossen. Die harmonische Bildgebung war der fundamentalen Bildgebung in allen untersuchten Parametern signifikant überlegen (p<0,001). HI war bei 90 Patienten bei der Wand des Darms 81-mal, beim Lumen des Darms 85-mal und bei der Bildqualität 85-mal FI überlegen. Bei 19 der Kinder wurden Darmpathologien detektiert (15x Dilatation, 2x Wandverdickung und 2x Dilatation+Wandverdickung). Es besteht eine inverse Korrelation zwischen dem BMI-FAP und der Darstellbarkeit des Lumens bzw. der Bildqualität, unabhängig von der verwendeten Methode. Schlussfolgerungen: Bei der Sonographie des Darms im Kindesalter zeigt sich die harmonische Bildgebung der fundamentalen Bildgebung signifikant überlegen. Es sollte daher bei Fragestellungen, die den Darm betreffen, auch in der Pädiatrie bevorzugt Harmonic Imaging angewendet werden. N2 - Bowel Sonography in Children – Comparison between fundamental and harmonic Imaging. Purpose: Harmonic Imaging (HI) was introduced to further ultrasonic scans for obese adults. It has hardly been investigated if the same method would present an advantage for children who due to their physical nature have better conditions for scanning. The following essay deals with the questions if HI presents an advantage towards FI for bowel sonography in children. Material and Methods: Four pairs of images have been taken of 90 children (f:m=46:44) with a linear 7.5MHz linear transducer both with HI and FI. Those images have been evaluated according to a ten-step scale. The effect of age, gender and BMI-FAP on the imaging of the bowel has been additionally investigated. It was also observed if pathology of the bowel like bowel wall thickening and dilatation were present. Results: With 17 of the patients a pair of images each had to be excluded. The HI was significantly superior to the FI in all the investigated parameters (p<0,001). The HI was 81 times superior to the FI with bowel wall, 85 times with bowel lumen and 85 times with the image quality. In 19 children bowel pathologies were detected (15 times dilatation, 2 times bowel thickening and 2 times dilatation + bowel thickening). There is a inverse co-relation between the BMI-FAP and the imaging of the lumen the image quality respectively independent from the used method. Conclusion: When dealing with bowel sonography in childhood the HI is significantly superior to the FI. It is therefore advisable when concerning the bowel to prefer the HI towards the FI even in paediatric. KW - Darmsonographie KW - Kinder KW - harmonische Bildgebung KW - BMI KW - bowel sonography KW - children KW - harmonic imaging KW - BMI Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-22964 ER - TY - THES A1 - Savic-Quilez, Julia T1 - Die Wertigkeit der MRT im Umfeld einer spezialisierten Schultersprechstunde - eine retrospektive Analyse von 89 Patienten - T1 - The value of the mri in a specialized shoulder-clinic setting - a retrospective evaluation of 89 patients - N2 - Obwohl der klinische Stellenwert der MRT in zahlreichen Studien für verschiedene Entitäten (AC-Komplex, coracoidale Pathologien, Rotatorenmanschette, Pathologien des Kapsel-Band-Apparates und der Bicepssehne sowie primär und reaktiv bedingte entzündliche Veränderungen) belegt ist, überrascht es, dass in der Literatur keine Arbeiten darüber existieren, inwieweit das Ergebnis der MRT-Untersuchung tatsächlich das therapeutische Procedere beeinflusst. Vorliegende Arbeit untersuchte daher den diagnostischen Impact der MRT im Setting einer hochspezialisierten Schultersprechstunde. N2 - Although the clinical significance of the mri concerning different entities (ac-joint, coracoidal pathologies, rotator cuff lesions, etc.) has been proven in several studies, it's unexpected that there are no studies about how the result of a mri-screening affects effectively the therapeutic proceedings. Thus current study considered the diagnostic impact of the mri in a specialized shoulder-clinic setting. KW - NMR-Tomographie KW - Akromioklavikulargelenk KW - MRT KW - Schulter KW - Rotatorenmanschettenläsion KW - SLAP-Läsion KW - Bizepssehnenpathologie KW - mri KW - shoulder KW - rotator cuff lesion KW - SLAP-lesion KW - ac-joint Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-46114 ER - TY - THES A1 - Sauerburger, Laura T1 - Diffusionsgewichtete MRT bei pädiatrischen Patienten mit Morbus Crohn T1 - Diffusion-weighted MRI in pediatric patients with Crohn disease N2 - Durch Weiterentwicklungen der MR-Technologie hat die diffusionsgewichtete MRT in der Bildgebung des Abdomens zunehmend an Bedeutung gewonnen. Einige wenige Studien zeigten bereits vielversprechende Ergebnisse für den Einsatz der DWI in der Diagnostik und Verlaufsbeurteilung des Morbus Crohn. Ziel dieser Arbeit war es, zu untersuchen, ob die DWI zur Detektion entzündlicher Darmwandläsionen und extraluminaler Komplikationen bei pädiatrischen Patienten mit Morbus Crohn ebenso geeignet ist wie die kontrastmittelverstärkte MRT. Hierzu wurden retrospektiv die klinischen und MR-tomographischen Daten von 48 Kindern, Jugendlichen und jungen Erwachsenen mit Morbus Crohn sowie von 42 Kontrollpatienten ausgewertet, bei denen im Zeitraum zwischen Juli 2008 und Mai 2013 eine MRT-Untersuchung durchgeführt wurde. Aktuelle Befunde einer Ileokoloskopie waren als Referenz bei 60% der Morbus Crohn Patienten und bei etwa einem Drittel der Patienten der Kontrollgruppe vorhanden. Das Bestehen eines Morbus Crohn konnte bei 47 der insgesamt 48 Patienten anhand der diffusionsgewichteten Sequenzen und in 46 Fällen mittels der kontrastverstärkten T1w-Aufnahmen korrekt nachgewiesen werden. Extramurale Komplikationen wie Abszesse oder Fisteln konnten sowohl mittels DWI als auch durch die KM-MRT detektiert werden. Da die DWI weder eine intravenöse Kontrastmittelapplikation noch Atemanhaltetechniken erfordert, ist sie gerade bei pädiatrischen Patienten ein geeignetes Bildgebungsverfahren. Wegen der relativ geringen Ortsauflösung der diffusionsgewichteten Sequenzen sollte jedoch zusätzlich eine Standardsequenz, wie die T2-gewichtete HASTE-Sequenz, akquiriert werden. Nach den Ergebnissen dieser Studie ist die diffusionsgewichtete MRT zur Beurteilung der entzündlichen Veränderungen des Morbus Crohn sehr gut geeignet und besitzt das Potenzial, nicht nur ergänzend, sondern als Alternative zur KM-MRT zum Einsatz zu kommen. N2 - The purpose of this retrospective study was to evaluate the detectability of inflammatory bowel lesions and of extramural complications with diffusion-weighted MRI (DWI), compared to contrast-enhanced MRI (CE-MRI), in pediatric patients with Crohn disease. The study included 48 children and young adults with Crohn disease and 42 matched controls who underwent routine MRI with DWI and contrast-enhanced T1-weighted sequences during a 5-year-period. Colonoscopy as reference standard was available in about two-thirds of the children with Crohn disease and in about one-third of controls. Overall diagnostic accuracy for identifying pediatric patients with inflammatory bowel lesions among patients and controls in our study was 99% (89/90) for DWI and 98% (88/90) for CE-MRI. In conclusion, the results suggest that free-breathing DWI has potential as an alternative to standard CE-MRI protocols in pediatric patients with known or suspected Crohn disease, without a substantial loss of diagnostic information and without the need for intravenous administration of contrast medium. KW - DW-MRI KW - Diffusionsgewichtete Magnetresonanztomographie KW - Diffusions-MRT KW - Pädiatrie KW - Morbus Crohn KW - DWI KW - abdominale Bildgebung Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-167851 ER - TY - JOUR A1 - Sauer, Stephanie A1 - Goltz, Jan P. A1 - Gassenmaier, Tobias A1 - Kunz, Andreas S. A1 - Bley, Thorsten A. A1 - Klein, Detlef A1 - Petritsch, Bernhard T1 - Partial Segmental Thrombosis of the Corpus Cavernosum (PSTCC) diagnosed by contrast-enhanced ultrasound: a case report JF - BMC Urology N2 - Background Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition. Case presentation We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid. Conclusion PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit. KW - MRI KW - priapism KW - corpus cavernosum KW - penile thrombosis KW - contrast-enhanced ultrasound Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126495 VL - 14 IS - 100 ER - TY - JOUR A1 - Sauer, Alexander A1 - Li, Mengxia A1 - Holl-Wieden, Annette A1 - Pabst, Thomas A1 - Neubauer, Henning T1 - Readout-segmented multi-shot diffusion-weighted MRI of the knee joint in patients with juvenile idiopathic arthritis JF - Pediatric Rheumatology N2 - Background: Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA). Methods: Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0–50 and 800 s/mm\(^2\)). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm\(^2\) were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence. Results: Fourteen (44%) patients had active synovitis and joint effusion, nine (28%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging. Conclusion: Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to “T2w shine-through” artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation. KW - diffusion-weighted MRI KW - juvenile idiopathic arthritis KW - synovitis Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158095 VL - 15 IS - 73 ER - TY - THES A1 - Sahmer, Peter T1 - Scannereigene akustische Aktivierung - Eine neue Pulssequenz vereinfacht fMRT des auditiven Kortex T1 - Scannernoise-evoked Activation - A new Pulse Sequence simplifies fMRT of the auditory Cortex N2 - Echo-planar Imaging (EPI) erzeugt durch schnell wechselnde Gradienten beträchtliche Schallemissionen. Dies führt nachgewiesenermaßen bei funktionellen Magnet-Resonanz-Tomographie- (fMRT-) Studien zu einer Aktivierung des auditiven Systems, insofern dieses beim jeweiligen Probanden in der Lage ist zu reagieren. Sowohl für auditive wie auch für nicht-auditive Untersuchungen wurden verschiedenste Anstrengungen unternommen, diese Interferenzen zu minimieren. Anstatt den Lärm des Scanners zu reduzieren oder die Transmission des Schalls zu behindern, war es nun das Ziel, eben diesen Schall zur Aktivierung des auditiven Kortex zu benutzen und diese mit fMRT-Untersuchungen nachzuweisen. Dieses geschieht schlicht durch das Auslassen von Read-Outs aus der Gradientenfolge der Pulssequenz. Diese Pulse sind die Hauptemissionsquellen von Schall des EPI, sie verursachen sowohl den Spitzenschallpegel als auch die Grundfrequenz, welche im umgekehrten Verhältnis zum Echo-Spacing steht. Durch eine Modell-gestützte Analyse wird gezeigt, dass das Auslassen von Read-Outs nach einem vordefinierten Schema verlässlich dazu geeignet ist, eine hämodynamische Blood-Oxygenation-Level-Dependent- (BOLD-) Signalveränderung im auditiven Kortex von normal hörenden Probanden (n=60) zu evozieren. Um den Nutzen der Technik beim auditiven fMRI zu zeigen, werden auf der Ebene der Einzelanalysen das traditionelle Family-Wise-Error-Rate- (FWER-) korrigierte Maximum Height Thresholding mit dem Spatial Mixture Modelling (SMM) verglichen. Mit Letzterem können so in 95 % der Fälle eine adäquate, bilaterale, auditive Aktivierung nachwiesen werden, wohingegen das FWER-basierte Voxel-Thresholding nur in 72 % aller Probanden eine solche Aktivierung zeigt. Um die klinische Anwendbarkeit der Technik unter pathologischen Bedingungen zu demonstrieren, wird ein Fallbericht einer Patientin vorgestellt, die an einem schweren, beidseitigen Sensorineural Hearing Loss (SNHL) aufgrund bilateraler Large Vestibular Aqueducts (LVAs) leidet. Dabei wird eben diese Modifikation benutzt, um präoperativ vor Cochlear Implantation (CI) zu zeigen, dass ein zentrales Resthörvermögen vorhanden ist. Da die Untersuchung völlig unabhängig von der Compliance des Patienten und kein zusätzliches Zubehör zum Scanner vonnöten sind, eignet sie sich hervorragend zu auditiven Untersuchungen, um so schnell das Hörvermögen zu prüfen. Dabei funktioniert die Methode unabhängig von äußerlichen Bedingungen: Bei hörgesunden Probanden ebenso wie bei Hörgeschädigten, bei Kindern, Jugendlichen und Erwachsenen aller Altersstufen sowie unabhängig von einer Sedierung während der Untersuchung. Beide benutzten Scanner zeigten unabhängig vom Gradienten oder der verwendeten Spule ein gleiches Ergebnis. N2 - Echo-planar Imaging (EPI) induces considerable sound emissions by steep gradient pulses. This leads evidentially to an activation of the auditory system, as much it is able to response in that particular subject. For auditory as well as non-auditory investigations, various efforts have been undertaken to minimize those interferences. Instead of reducing the scanner noise or cumbering its transmission, the goal was now to utilize it to activate the auditory cortex and detect it later on by functional magnetic resonance imaging (fMRI). This was achieved by simply omitting read-outs from the gradient train of an EPI pulse sequence. Those pulses are the primary noise determinant in EPI, they induce both the peak sound level and the fundamental frequency peak, which relates inversely to the echo spacing. By hypothesis-driven analyses it is demonstrated that withholding read-out gradients in a defined scheme reliably evokes hemodynamic Blood Oxygenation Level Dependent (BOLD) signal modulations in the auditory cortex of normal hearing subjects (n=60). To show the value of this new method, the first level analyses of the single subjects with the traditional Family-Wise-Error-Rate (FWER-) corrected Maximum Height Thresholding are compared with Spatial Mixture Modelling (SMM). This way in 95 % of all subjects an appropriate, bilateral auditory activation was detected with SMM, whereas the FWER-based Voxel-Thresholding revealed such activation in only 72 %. To show the clinical practicability of the new technique under pathological conditions the case report of a patient with severe, binaural Sensoneurinal Hearing Loss (SNHL) due to bilateral Large Vestibular Aqueducts (LVA) is presented. Thereby this modification is used to confirm residual audition prior to cochlear implantation (CI). As the investigation is totally independent of the patient's compliance and no additional equipment other than the scanner is necessary, it is suited well as a quick testing for central audition. At the same time the approach is absolutely independent from other conditions: It works with normal hearing subjects as well as with hearing impaired patients; with children, adolescents as well as adults of all age brackets and regardless of sedation during the test. Both scanners, that were used, showed independent from the gradient or the coil the same results. KW - fMRT KW - auditiver Kortex KW - Read-out KW - BOLD KW - fMRT KW - auditiver Kortex KW - Read-out KW - BOLD KW - fMRT KW - auditory cortex KW - read-outs KW - scannernoise KW - BOLD Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-28083 ER - TY - THES A1 - Rüber, Matthias T1 - Deterministische und probabilistische Traktographie mittels Diffusions Tensor Imaging unter aversiven Diffusionsbedingungen T1 - Determinstic and probabilistic fibre tracking with diffusion tensor imaging under aversive diffusion conditions N2 - Die diffusionsgewichtete Magnetresonanztomographie (DW-MRT) ist ein fester Bestandteil der radiologischen Diagnostik des Zentralnervensystems (ZNS), und zwar nicht nur bei Schlaganfällen sondern zunehmend auch bei Hirntumoren, Schädelhirntraumata, demyelinisierenden, degenerativen sowie entzündlichen Erkrankungen. Diese Pathologien gehen in der Regel mit einer Veränderung der lokalen Diffusionsbedingungen einher, die eine reguläre Diffusionsbildgebung beeinträchtigen. Durch die Bestimmung der Diffusionsparameter lassen sich mit Hilfe verschiedener mathematischer Verfahren Faserverbindungen visualisieren. Wie sich diese unterschiedlichen Methoden in Regionen mit aversiven Diffusionsbedingungen verhalten, konnte mit der Arbeit erstmals systematisch gezeigt werden. Hierzu wurden 29 Patientenuntersuchungen ausgewertet. Als Einschlusskriterium galt eine unilaterale, diffusionsrelevante Läsion mit Bezug zur Pyramidenbahn. Ausschlusskriterium war eine vollständige Hemiparese als Zeichen einer vollständigen Zerstörung der relevanten Leitungsbahn. Im Einzelnen handelte es sich bei den untersuchten Läsionen um drei höhergradige Astrozytome (WHO Grad III-IV), drei niedriggradige Astrozytome, acht Glioblastome, zwei Karzinommetastasen, zwei arteriovenöse Malformationen und je eine entzündliche Parasitose, ein Oligodendrogliom, eine Gliomatose und ein Kavernom. Untersucht wurden zwei deterministische (einfaches und interpoliertes streamlining) und drei probabilistische Methoden (ohne crossing fibers; mit Berechnung von zwei Fasern pro Voxel und constrained/bayesian). Läsionen jeglicher Art verursachten signifikant mehr Fehlschläge bei deterministischer als bei probabilistischer Traktographie. In neun Untersuchungen bei einfacher und in acht Untersuchungen bei interpolierter Traktographie zeigten sich fasch negative Ergebnisse. Probabilistisches Traktographieren eliminiert nicht falsch negative Ergebnisse, reduziert sie jedoch unter den oben genannten aversiven Difussivitätsbedingungen mit denen intraaxiale Läsionen einhergehen. Klinisches Wissen über die verbliebene Traktintegrität ermöglicht die Umwandlung der Traktographieergebnisse in Wahrscheinlichkeitswerte innerhalb eines Bayschen Modells. Außerdem ist nur unter Miteinbeziehung klinischer Informationen eine Traktographie nach dem constrained Modell möglich. Obwohl die probabilistische Traktographie weniger anfällig für falsch negative Ergebnisse ist als die deterministische, geht die erhöhte Sensitivität der Algorithmen auf Kosten der Spezifität. Dies zeigt sich in signifikant erhöhten bilateralen Traktvolumina und einem übermäßigen Unterschied der Traktvolumina von Läsionsseite zu kontralateraler Seite. Die probabilistisch, unconstrained durchgeführte Traktographie der Pyramidenbahn zeigte eine signifikant, durch die Läsion verursachte Volumenminderung des Traktes, während dies im constrained modellierten Fall durch die Daten nicht gezeigt werden konnte. Dies zeigt die Robustheit des Constrained Modells unter den aversiven klinischen Bedingungen einer intraaxialen Läsion ohne den Nachteil von erhöhten Fehltraktographien. Es kann konstatiert werden, dass sich die deterministischen Traktographieverfahren zur präoperativen Orientierung vor neurochirurgischen Eingriffen eignen. Jedoch ist eine nicht zu unterschätzende Anzahl von falsch negativen Ergebnissen zu berücksichtigen. In zweifelhaften Fällen sollte zusätzlich eine Darstellung mittels probabilistischen Algorithmen, am besten mittels Constrained Modell durchgeführt werden. N2 - Diffusion weighted magnetic resonance imaging (DW-MRI) is a common part of radiologic diagnostics of the central nervous system (CNS). Not only for the diagnosis of strokes but also in tumors, trauma, degenerative, demyelinising and inflammatory diseases. These pathologies normally include an affection of local diffusion parameters, witch impede a regular diffusion imaging. Through estimating diffusion parameters it is possible to visualize fibre connections with different mathematical methods (diffusion tensor imaging, DTI). For the first time in this thesis it could be shown how these different methods are affected by aversive diffusion conditions. 29 examinations were evaluated. Including criteria in the study were unilateral diffusion relevant lesions with reference to the pyramidal tract. Exclusion criteria were a complete paresis or plegia as sign for a complete destruction of the relevant tract. In special 3 high grade astrocytomas (WHO III-IV) 3 low grade astrozytomas, 8 glioblastomas, 2 metastasis, 2 artero-venous-malformations and each one parasitosis, oligodendroglioma, gliomatosis and cavernoma. Two deterministic (one with a fixed step length and one with probabilistic sampling)) and three probabilistic methods (with /without crossing fibres and within a constrained Bayesian framework) were performed on the same data. Lesions of all kinds caused significantly more false negative results in deterministic tracking. 9 examinations in simple and 8 in interpolated traktographies showed false negative results. Probabilistic tracking did not eliminate false negative results, but reduced them under the aversive diffusion parameters. Clinical knowledge on remaining tract integrity allows the conversion of the tracing results into probabilities within a Bayesian model. The lowered false negative rate of the probabilistic methods compared to the deterministic methods is the raised sensitivity at expenses on a lowered specificity. This can be seen in significantly raised bilateral tract lumina and an overestimated difference between tract volumes on lesion and non affected side. The probabilistic unconstrained tractographie showed a significant lowered tract volume due to the lesion; however this could not be shown for the constrained modelling. This shows the robustness of the constrained model under the aversive clinical conditions of intraaxial lesions without the disadvantage of more false tractrographies. It can be stated, that preoperative tractographies are a useful instrument of pre interventional orientation before neurosurgical operations. However a not quite low number of false negative results have to be accounted. In problematic cases an additional visualisation with probabilistic algorithms should be performed, preferably in a constrained model. KW - NMR-Tomographie KW - Anisotrope Diffusion KW - Diffusion KW - Ödem KW - Pyramidenbahn KW - Hirntumor KW - Diffusion Tensor Imaging KW - DTI KW - fibre tracking KW - oedema KW - deterministic KW - probabilistic Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-39118 ER - TY - THES A1 - Runge-Hiemer, Pamela T1 - Elastographie (qualitativ und semiquantitativ) am Hals bei Kindern und Jugendlichen T1 - Elastography (qualitative and semiquantitative) of the neck of children and adolescents N2 - In unserer Studie kamen die neuen Verfahren qualitative und semiquantitative Elastographie zum Einsatz. Es sollte gezeigt werden, ob sie als Ergänzung zu den herkömmlichen sonographischen Verfahren die Diagnosestellung von Erkrankungen am Hals bei Kindern und Jugendlichen verbessern können. Bei der Untersuchung mittels semiquantitativer Elastographie konnten wir in unserer Studie beim Vergleich Schilddrüsen-Normalbefund und Hashimoto-Thyreoiditis einen signifikanten Unterschied der Scherwellengeschwindigkeiten nachweisen. Es zeigte sich, dass Patienten mit Hashimoto-Thyreoiditis signifikant höhere Scherwellengeschwindigkeiten aufweisen als Patienten mit Normalbefund. Für die anderen untersuchten Schilddrüsenerkrankungen, Struma diffusa und Struma nodosa und für die Erkrankungen der Lymphknoten, benigne Veränderung/Entzündung, maligne Veränderung und Abszess, ließ sich kein signifikanter Unterschied feststellen. Die Sensitivität und Spezifität konnte durch Einsatz des neuen Verfahrens der qualitativen Elastographie nicht gesteigert werden. Während sich bei der Schilddrüsendiagnostik geringere Werte für Sensitivität und Spezifität im Vergleich zu den herkömmlichen Verfahren zeigten, unterschieden sich die Werte bei der Lymphknotenuntersuchung Reader-abhängig. Bei der Schilddrüsenuntersuchung lag die Bildqualität der konventionellen Sonographie über der der qualitativen Elastographie. Dagegen wurde bei der Lymphknotenuntersuchung die Bildqualität der Elastographiebilder höher bewertet als jene der herkömmlichen Verfahren. Insgesamt konnte in unserer Studie gezeigt werden, dass Patienten mit Hashimoto-Thyreoiditits signifikant höhere Scherwellengeschwindigkeiten im Schilddrüsengewebe aufweisen, als bei Normalbefund. In der Diagnostik von Schilddrüsen- und Lymphknotenerkrankungen konnte bezüglich des neuen Verfahrens der qualitativen Elastographie eine Überlegenheit gegenüber der konventionellen Sonographie nicht nachgewiesen werden. Um die Ergebnisse unserer Studie abschließend bewerten zu können, wäre eine Validierung anhand einer größeren Patientengruppe nötig. N2 - In our study we used the new ultrasound procedures qualitative and semiquantitative Elastography. We wanted to show if those new methods could improve conventional ultrasound in the diagnostic of children and adolescents. In the study with semiquantitative Elastography we could show that there was a significant difference in the shear-wave velocity between normal thyroid glands and Hashimoto-Thyroiditis. The velocity of the shear waves was higher in patients with Hashimoto-Thyroiditis compared to those with normal findings. For other disorders such as struma diffusa or nodosa or affection of the lymph nodes (benign or malign diseases or inflammation) no differences in shear-wave velocities were found. Sensitivity or specificity could not be increased by the use of qualitative Elastography. Disorders of the thyroid gland showed only slightly lower values compared to conventional ultrasound, on the other hand disorders of the lymph node were reader-dependent. In the diagnostic of the thyroid gland the quality of the imaging of conventional ultrasound was superior to that of the qualitative Elastography. In the study of the lymph nodes the quality of the imaging was better in the Elastography. Altogether it could be shown that patients with Hashimoto-Thyroiditis had higher shear-wave velocities than patients with normal findings. In the diagnostic of other thyroid or lymph node disorders no superiority of the new procedures could be shown compared to conventional ultrasound. To validate our findings we recommend the implementation of studies with larger patient populations. KW - Elastographie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-135048 ER - TY - JOUR A1 - Ruf, Katharina A1 - Beer, Meinrad A1 - Köstler, Herbert A1 - Weng, Andreas Max A1 - Neubauer, Henning A1 - Klein, Alexander A1 - Platek, Kathleen A1 - Roth, Kristina A1 - Beneke, Ralph A1 - Hebestreit, Helge T1 - Size-adjusted muscle power and muscle metabolism in patients with cystic fibrosis are equal to healthy controls – a case control study JF - BMC Pulmonary Medicine N2 - Background Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF. Methods Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism. Results Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy. Conclusions The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism. KW - Cystic fibrosis KW - Exercise capacity KW - MRI spectroscopy KW - Muscle power KW - Phosphorylation KW - Lung disease, KW - Muscle function Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-200981 VL - 19 ER - TY - THES A1 - Robrecht, Julia T1 - Diagnostik des Vesikoureteralen Reflux : In-vitro-Vergleich eines Ultraschallkontrastmittels der 1. mit einem der 2. Generation T1 - comparison of a first and a second generation contrastagent for the diagnosis of vesicourethral reflux with ultrasound N2 - ZIEL: In den letzten Jahren ist die kontrastverstärkte sonographische Refluxprüfung, d.h. die Miktionsurosonographie (MUS), zunehmend zu einer Alternative gegenüber der standardmäßig eingesetzten Miktions-zysturethrographie (MCU) für die Diagnostik des vesikoureteralen Reflux (VUR) geworden. Eine der Einschränkungen sind jedoch die sehr hohen Kosten des Ultraschallkontrastmittels. Durch Entwicklung von neuen Ultraschallkontrastmitteln erhofft man sich aufgrund vergleichbarer Bildqualität in deutlich niedrigerer Dosis entsprechend eine Reduktion der Kosten zu erreichen. Thema dieser Studie ist eines dieser neuen Ultraschallkontrastmittel (SonoVue®) mit dem in der Routine verwendeten US-Kontrastmittel Levovist® in-vitro unter Betrachtung der für die Refluxdiagnostik relevanten physikalisch-chemischen Eigenschaften zu vergleichen. MATERIAL UND METHODEN: Der in-vitro Versuchsaufbau simulierte die in-vivo durchgeführte MUS. Verwendet wurden die Abbildungsmodalitäten Fundamental und Harmonic Imaging (THI/ECI, Sonoline Elegra®, Siemens), letztere sowohl mit einem niedrigen als auch mit einem hohen Mechanical Index (MI). SonoVue® wurde in einer Konzentration von 0,25%, 0,5% und 1%, Levovist in einer Konzentration von 5% bezogen auf ein Gesamtvolumen in-vitro von 20ml getestet. Als Vergleichsparameter diente die in-vitro Kontrastdauer. Diese wurde definiert als der Zeitraum vom Beginn der Messung bis zu dem Zeitpunkt, an dem auf mehr als 50% der Bildfläche keine echogenen Mikrobläschen mehr nachweisbar waren. ERGEBNISSE: Die Änderung der oben genannten Konzentrationen hatte keinen entscheidenden Einfluss auf die Kontrastdauer von SonoVue®. Darüber hinaus konnte beim Umschalten von THI low MI auf THI high MI die Kontrastdauer von SonoVue® signifikant verlängert werden. Betrachtet man die Abbildungsmodalität THI mit hohem MI, welche routinemäßig bei Levovist® angewendet wird, so zeigte sich, dass die Kontrastdauer bei Levovist® in einer Konzentration von 5% bei 1,1 Minuten lag, bei SonoVue® hingegen erhielten wir bei einer Konzentration von 1% eine Kontrastdauer von 7,3 Minuten. Dies bedeutet, dass trotz Verwendung einer fünffach geringeren Dosis bei SonoVue® sich die Kontrastdauer in-vitro um mehr als 80% verlängerte. Darüber hinaus blieb die Kontrastdauer von SonoVue® über einen Zeitraum von 6 Stunden weitestgehend stabil, während bei Levovist® die Kontrastdauer schon nach 0,5 Stunden eine deutliche Reduktion zeigte. SCHLUSSFOLGERUNG: Es ist zu erwarten, dass SonoVue® auch bei intravesicalen Applikationen in einer deutlich niedrigeren Dosis (1% des Blasenvolumens) verwendet werden kann und dass mehrere Untersuchungen über einen längeren Zeitraum mit einer Flasche SonoVue® durchgeführt werden können. Somit würde eine Kostenreduktion erreicht werden. N2 - PURPOSE: Contrast-enhanced sonographic reflux diagnosis, i.e. voiding urosonography [VUS], is gradually becoming an alternative diagnostic imaging modality for vesicoureteric reflux [VUR]. A limiting factor for the widespread application of VUS is the cost of the US contrast agents. With the development of new US contrast agents and the possibility of reducing the administered dose, it is envisaged to lower the cost. The aim of this study was to compare in-vitro the new US contrast agent (SonoVue®) with the routinely used contrast agent, Levovist®, taking into consideration those for reflux diagnosis relevant physico-chemical properties. MATERIALS AND METHODS: The in-vitro experimental set-up simulated the in-vivo VUS. The US modalities fundamental and harmonic imaging (THI/ECI, Sonoline Elegra®, Siemens) were utilized, the latter with both low and high mechanical Indices (MI). SonoVue® was tested in concentrations of 0.25%, 0.5% and 1% and Levovist® at 5%. The in-vitro contrast duration served as the parameter for comparison. This was defined as the time from the start of the experiment until the time when more than 50% of the image area was free of microbubbles. RESULTS: The use of different concentrations of SonoVue® did not have any impact on the contrast duration. When the US modality was switched from low to high MI the contrast duration of SonoVue® turned out to be significantly longer. It was also shown that when THI high MI, the routinely employed US modality with Levovist®, was tested the contrast duration of Levovist® at a concentration of 5% was 1.1 min, whereas that of SonoVue® at a concentration of 1% reached 7.3 min. This means that despite SonoVue® being administered at a dose five times less than Levovist®, the in-vitro contrast duration increased by more than 80%. Moreover, a freshly prepared suspension of SonoVue® did not show change in the contrast duration for nearly 6 hours. In the case of Levovist® there was a significant reduction of the contrast duration just after half-an-hour. CONCLUSION: It is expected that with the use of SonoVue® in-vivo a significant dose reduction is possible and thus one vial can be used for more than one examination. Consequently, visible cost reduction will ensue. KW - VUR KW - Ultraschall KW - SonoVue KW - MUS KW - Kontrastmittel KW - VUR KW - ultrasound KW - SonoVue KW - MUS KW - constrastagent Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-22418 ER - TY - JOUR A1 - Riedl, Katharina A. A1 - Kampf, Thomas A1 - Herold, Volker A1 - Behr, Volker C. A1 - Bauer, Wolfgang R. T1 - Wall shear stress analysis using 17.6 Tesla MRI: A longitudinal study in ApoE\(^{-/-}\)mice with histological analysis JF - PLoS One N2 - This longitudinal study was performed to evaluate the feasibility of detecting the interaction between wall shear stress (WSS) and plaque development. 20 ApoE\(^{-/-}\)mice were separated in 12 mice with Western Diet and 8 mice with Chow Diet. Magnetic resonance (MR) scans at 17.6 Tesla and histological analysis were performed after one week, eight and twelve weeks. Allin vivoMR measurements were acquired using a flow sensitive phase contrast method for determining vectorial flow. Histological sections were stained with Hematoxylin and Eosin, Elastica van Gieson and CD68 staining. Data analysis was performed using Ensight and a Matlab-based "Flow Tool". The body weight of ApoE\(^{-/-}\)mice increased significantly over 12 weeks. WSS values increased in the Western Diet group over the time period; in contrast, in the Chow Diet group the values decreased from the first to the second measurement point. Western Diet mice showed small plaque formations with elastin fragmentations after 8 weeks and big plaque formations after 12 weeks; Chow Diet mice showed a few elastin fragmentations after 8 weeks and small plaque formations after 12 weeks. Favored by high-fat diet, plaque formation results in higher values of WSS. With wall shear stress being a known predictor for atherosclerotic plaque development, ultra highfield MRI can serve as a tool for studying the causes and beginnings of atherosclerosis. KW - phase-contrast MRI KW - flow patterns KW - blood flow KW - apolipoprotein-E KW - atheriosclerosis KW - mouse KW - mice KW - quantification KW - association KW - lesions Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229318 VL - 15 IS - 8 ER - TY - THES A1 - Richter, Julian Alexander Jürgen T1 - Wave-CAIPI for Accelerated Dynamic MRI of the Thorax T1 - Beschleunigte Dynamische MR-Bildgebung des Thorax mit wave-CAIPI N2 - In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be quantified by means of noise and SNR calculations. An SNR gain can be traded for a reduced scan time, i.e., additional undersampling, or for an enhanced image quality, keeping scan time constant. Acceleration of MR imaging is especially important in dynamic applications, since these examinations are inherently time-consuming. The impact of wave-CAIPI sampling on image quality and its potential for scan time reduction was investigated for two dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI. Dynamic 3D Lung MRI By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans could be enhanced. Volunteer examinations were used to quantify image quality by means of similarity between accelerated and reference images. To this end, the normalized mutual information and the root-mean-square error were chosen as quantitative image similarity measures. The wave-CAIPI sampling was shown to exhibit superior quality, especially for short scan times. The values of the normalized mutual information were (10.2 +- 7.3)% higher in the wave-CAIPI case -- the root-mean-square error was (18.9 +- 13.2)% lower on average. SNR calculations suggest an average SNR benefit of around 14% for the wave-CAIPI, compared to Cartesian sampling. Resolution of the lung in 8 breathing states can be achieved in only 2 minutes. By using the wave-CAIPI k-space trajectory, precise tumor delineation and assessment of respiration-induced displacement is facilitated. Cardiac 4D Flow MRI In 4D flow MRI, acceleration of the image acquisition is essential to incorporate the corresponding scan protocols into clinical routine. In this work, a retrospective 6-fold acceleration of the image acquisition was realized. Cartesian and wave-CAIPI 4D flow examinations of healthy volunteers were used to quantify uncertainties in flow parameters for the respective sampling schemes. By employing wave-CAIPI sampling, the estimated errors in flow parameters in 6-fold accelerated scans could be reduced by up to 55%. Noise calculations showed that the noise level in 6-fold accelerated 4D flow acquisitions with wave-CAIPI is 43% lower, compared to Cartesian sampling. Comparisons between Cartesian and wave-CAIPI 4D flow examinations with a prospective acceleration factor R=2 revealed small, but partly statistically significant discrepancies. Differences between 2-fold and 6-fold accelerated wave-CAIPI scans are comparable to the differences between Cartesian and wave-CAIPI examinations at R=2. Wave-CAIPI 4D flow acquisitions of the aorta could be performed with an average, simulated scan time of under 4 minutes, with reduced uncertainties in flow parameters. Important visualizations of hemodynamic flow patterns in the aorta were only slightly affected by undersampling in the wave-CAIPI case, whereas for Cartesian sampling, considerable discrepancies were observed. N2 - Die wave-CAIPI k-Raum Trajektorie stellt eine effiziente Methode für beschleunigte MRT Akquisitionen dar. Die Benutzung der wave-CAIPI Trajektorie anstelle der kartesischen Standardmethode in der parallelen Bildgebung führt zu einem reduzierten Rausch-Niveau in den rekonstruierten Bildern. Dieser Effekt kann durch Berechnungen des Rauschpegels und des Signal-zu-Rausch Verhältnisses (SNR) quantifiziert werden. Das höhere Signal-zu-Rausch Verhältnis kann genutzt werden, um entweder die Akquisition durch eine höhere Unterabtastung zu beschleunigen, oder um die Bildqualität zu verbessern. Die Beschleunigung von MRT Akquisitionen ist besonders in dynamischen Anwendungen wichtig, da diese Untersuchungen inhärent sehr zeitaufwendig sind. Der Einfluss der wave-CAIPI Methode auf die Bildqualität und das Beschleunigungspotenzial der Messung wurde in dieser Arbeit sowohl für selbst-navigierte, dynamische 3D Lungenbildgebung, als auch für 4D Fluss MRTs des Herzens untersucht Dynamische 3D Lungen MRT Durch die Verwendung der wave-CAIPI Samplingmethode konnte die Bildqualität von selbst-navigierten, dynamischen 3D Lungen MRTs bei freier Atmung verbessert werden. Eine wichtige Anwendung dieser Technik liegt im Bereich der Strahlentherapieplanung. Dabei wurde im Rahmen einer Probandenstudie die Bildqualität anhand der Ähnlichkeit zwischen beschleunigten Bildern und den jeweiligen Referenzen quantifiziert. Zu diesem Zweck wurden die normalized mutual information und der root-mean-square error als quantitative Maße gewählt. Es konnte gezeigt werden, dass -- besonders bei kurzen Akquisitionszeiten -- die wave-CAIPI Methode zu besserer Bildqualität führte, verglichen mit dem kartesischen Standard. Berechnungen der normalized mutual information ergaben im Mittel (10.2 +- 7.3)% höhere Werte für die wave-CAIPI Methode -- der root-mean-square error war (18.9 +- 13.2)% geringer. Darüber hinaus lieferte die wave-CAIPI ein um etwa 14% höheres mittleres SNR. In 2 Minuten konnte die Atembewegung der Lunge in 8 Atemzustände aufgelöst werden. Eine präzise Tumor-Abgrenzung und die Evaluierung von respirationsinduzierten Tumorbewegungen wird durch die Verwendung der wave-CAIPI Methode vereinfacht. 4D Fluss Herz MRT Die Beschleunigung von 4D Fluss MRTs ist essentiell, um solche Untersuchungen in die klinische Routine zu integrieren. In der präsentierten Arbeit wurde eine 6-fache retrospektive Beschleunigung realisiert. 4D Fluss Untersuchungen von gesunden Probanden mit der wave-CAIPI und mit der kartesischen Samplingmethode wurden verwendet, um Unsicherheiten in verschiedenen Flussparametern für die beiden Samplingmethoden zu berechnen. Dabei zeigte sich, dass die geschätzten Fehler in den Flussparametern der 6-fach beschleunigten wave-CAIPI Untersuchungen bis zu 55% geringer sind als die Fehler der kartesischen Messungen. Ferner zeigten Rausch-Analysen, dass die beschleunigten wave-CAIPI Aufnahmen ein um 43% geringeres Rausch-Niveau aufweisen. Vergleiche zwischen Flussparametern, die aus 2-fach beschleunigten wave-CAIPI und kartesischen Messungen berechnet wurden, zeigten kleine, aber teilweise statistisch signifikante Unterschiede zwischen den beiden Methoden. Unterschiede zwischen 2-fach und 6-fach beschleunigten wave-CAIPI Aufnahmen sind vergleichbar mit den Unterschieden zwischen der wave-CAIPI Methode und der kartesischen Methode bei R=2. Wave-CAIPI 4D Fluss Aufnahmen des Herzens konnten mit einer mittleren, simulierten Aufnahmezeit von unter 4 Minuten durchgeführt werden. Die effizientere Samplingmethode ermöglichte dabei erheblich reduzierte Unsicherheiten in den berechneten Flussparametern. Wichtige Visualisierungen des Blutflusses in der Aorta wurden im Falle der wave-CAIPI Methode kaum von der Unterabtastung beeinflusst. Hingegen wiesen die Visualisierungen der beschleunigten kartesischen Messungen erhebliche Diskrepanzen auf. KW - Magnetresonanztomographie KW - Lunge KW - Herz KW - Fluss KW - Lung KW - Heart KW - Flow Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-232071 ER - TY - JOUR A1 - Richter, Julian A. J. A1 - Wech, Tobias A1 - Weng, Andreas M. A1 - Stich, Manuel A1 - Weick, Stefan A1 - Breuer, Kathrin A1 - Bley, Thorsten A. A1 - Köstler, Herbert T1 - Free‐breathing self‐gated 4D lung MRI using wave‐CAIPI JF - Magnetic Resonance in Medicine N2 - Purpose The aim of this study was to compare the wave‐CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free‐breathing 4D lung MRI. Methods The wave‐CAIPI k‐space trajectory was implemented in a respiratory self‐gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave‐CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study. Results The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave‐CAIPI approach. Average normalized mutual information values of the wave‐CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave‐CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave‐CAIPI. Conclusion The application of the wave‐CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave‐CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant. KW - free‐breathing KW - lung KW - self‐gated KW - wave‐CAIPI Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-218075 VL - 84 IS - 6 SP - 3223 EP - 3233 ER - TY - THES A1 - Richter, Julia Babette Marianne T1 - Vergleich der Wertigkeit von Magnetresonanz-Enterographie und farbkodierter Duplex-Sonographie bei chronisch entzündlichen Darmerkrankungen im Kindes- und Jugendlichenalter T1 - Comparison of the validity of magnetic resonance enterography and colour-coded duplex sonography in chronic inflammatory bowel disease in childhood and youth N2 - In der S3-Leitlinie „Diagnostik und Therapie des Morbus Crohn“ von 2008 war lediglich die Sonographie als primär bildgebendes Verfahren verankert; der Einsatz der Dünndarm-MRT blieb optional und ohne feste Position im Diagnostik-Algorithmus der CED. Im Unterschied hierzu stärkt die 2014 aktualisierte entsprechende S3-Leitlinie den Stellenwert der MRT als bildgebende Modalität. Weiterhin bestehen bleibt die Sonographie als primäre Bildgebung; eine MRT soll jedoch ebenfalls erfolgen: zur Primärdiagnostik, zur Erkennung extraintestinaler Komplikationen und zur Beurteilung endoskopisch nicht einsehbarer Darmabschnitte. Darüber hinaus kann sie in Verlaufskontrollen angewendet werden, falls erforderlich. Da sich diese jungen Patienten bei langer Krankheitsdauer in der Regel einer hohen Zahl an Untersuchungen unterziehen, sollte die Möglichkeit, dies strahlenexpositionsfrei durchführen zu können, unbedingt gewährleistet werden. Andernfalls ist mit einer erhöhten Rate an Malignomen im späteren Lebensalter zu rechnen. Daraus ergibt sich die Bedeutung einer Korrelation von mittels Ultraschall wie MRT erhobenen Befunden bei kindlicher CED. Hierzu liegen bislang nur wenige Untersuchungen vor, die zumeist auf den additiven Wert der Sonographie zur MRT und/oder dem additiven Wert der MR-Perfusionsanalyse fokussieren. Der hier vorgestellte Ansatz einer direkten Korrelation der Parameter Wanddicke und Perfusionsmarker zwischen Sonographie und MRT sowie gegenüber klinischen Aktivitätsmarkern (shPCDAI) ist innovativ. Für das MRT konnten wir eine signifikante Korrelation von Wanddicke und Signalintensitätszunahme zwei Minuten nach Kontrastmittelgabe für das terminale Ileum, der Prädilektionsstelle des Morbus Crohn, nachweisen. Ein Zusammenhang zwischen Wanddicke und klinischem Aktivitätsindex konnte nicht gezeigt werden, jedoch zwischen Signalintensitätszunahme und short PCDAI. Die Perfusionsanalyse sollte daher unserer Ansicht nach bei MRT-Untersuchungen zur Beantwortung der Frage „aktive Entzündung“ herangezogen werden. Für die Sonographie konnten wir keinen Zusammenhang von Wanddicke und Perfusion, jedoch eine signifikante Korrelation von Wanddicke und short PCDAI nachweisen. Die Perfusion korrelierte wiederum nicht mit dem klinischen Aktivitätsindex. Die morphologische Wanddickenanalyse sollte daher für Sonographie-Untersuchungen zur Beantwortung der Frage „aktive Entzündung“ herangezogen werden. Bei der Korrelation der MRT- und Sonographie-Ergebnisse zeigte sich ein gutes Übereinstimmen der Daten der Darmwanddicken-Messungen, die höchste Korrelation ergab sich im terminalen Ileum. Auch für Signalintensitätszunahmen (MRT) und Perfusion (FKDS) zeigte sich ein gutes Übereinstimmen – mit Ausnahme des Rektosigmoids (späte KM-Phase). Die größte Korrelation war auch hier im terminalen Ileum zu finden. Dies belegt die gute Vergleichbarkeit beider Modalitäten. Eine Korrelation von MRAIs – USAI – shPCDAI ließ sich nicht nachweisen. Dies könnte an einer divergenten Einschätzung der Erkrankungsaktivität, jedoch auch an der kleinen Fallzahl liegen. Zur Erstellung des shPCDAI waren die retrospektiv erhobenen Variablen teils nicht ausreichend. Hauptlimitation für den USAI war die – teils durch Darmgasüberlagerung bedingte – unvollständige Dokumentation. Die Stärke des MRAI lag dagegen bei konstant vorliegenden Messungen in fünf Darmabschnitten. Trotz dieser Limitationen belegt die vorliegende Arbeit die Gleichwertigkeit beider Methoden in der Beurteilung von Darmwanddicken und eine bessere Korrelation wie Aussagekraft der MRT bei der Perfusionsanalyse. Aktuelle Publikationen belegen die Bedeutung Diffusionsgewichteter-MR-Bildgebung bei der CED-Diagnostik. Die DWI wurde im Rahmen unserer Untersuchung nicht angewendet, wird aber in Zukunft als vielversprechender, additiver Baustein oder sogar Ersatz für die Kontrastmittelgabe (Perfusionsanalyse) für MRT bei CED zu evaluieren sein. N2 - Comparison of the validity of magnetic resonance enterography and colour-coded duplex sonography in chronic inflammatory bowel disease in childhood and youth KW - Magnetresonanztomographie KW - Duplexsonographie KW - Verlgeich KW - Magnetresonanz-Enterographie KW - chronisch-entzündliche Darmerkrankung KW - Kindesalter KW - Wertigkeit Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-140336 ER - TY - THES A1 - Remmert, Haiko T1 - Quantitative klinische kardiale MR-Spektroskopie - Optimierung und Anwendung bei Patienten mit akutem Myokardinfarkt im Rahmen einer umfassenden Analyse von Anatomie, Funktion und Metabolismus T1 - Quantitative clinical cardial MR spectroscopy - Optimization and application in patients with cardiac infarction within an extensive analysis of anatomy, function and metabolism N2 - Die 31P-MRS ist aktuell die einzige verfügbare nicht-invasive Methode mit der der Herzmetabolismus ohne radioaktive Tracer untersucht werden kann. MRS ermöglicht Einblicke in die Energetik der ischämischen Herzkrankheit, des Herzinfarkts, der hypertrophen Kardiomyopathie oder auch der Herzklappenfehler. Ferner kann die Methode zur Überwachung des Therapieerfolgs o.g. Krankheiten genutzt werden. Gegenwärtig wird die MR-Spektroskopie, aufgrund der geringen räumlichen und zeitlichen Auflösung sowie der geringen Reproduzierbarkeit, jedoch nur in der Forschung angewendet. Die Einführung von MRT-Sytemen höherer Feldstärke, z.B. 7 Tesla, wird vermutlich eine Optimierung der Auflösung und Reproduzierbarkeit ermöglichen und damit die 31P-MRS in die klinische Diagnostik integrieren können. Die vorliegende Arbeit befasst sich neben der methodischen Weiterentwicklung und Standardisierung der MRS mit einem direkten Vergleich MR-tomographischer (LE) und MR-spektroskopischer (AW-CSI) Techniken zur Detektion von Infarktfolgen. Hierbei konnte durch die simultane Anwendung von MRS und Late Enhancement, ein bereits in der klinischen Infarktdiagnostik etabliertes Verfahren, die Aussagekraft der MR-Spektroskopie in Bezug auf die Infarktlokalisation validiert werden. Ein wesentlicher Vorteil der MRS gegenüber dem Late Enhancement besteht darin, dass bereits frühzeitig pathologische Veränderungen des Metabolismus in Arealen wie dem remote, stunned oder hibernating myocardium detektiert werden können. Letztere demarkieren sich nicht beim LE. Unter Etablierung eines Segmentationsalgorithmus konnten sehr niedrige Variabilitäten bei dem verwendeten Quantifizierungsprogramm („SLOOP“) erreicht werden. Zusätzlich gelang es durch systematische Analysen die für die Auswertung der MRS benötigten Nachbearbeitungszeiten drastisch zu verkürzen. Als klinische Anwendung erfolgte die Bestimmung des kardialen Metabolismus mittels akquisitionsgewichteter 31P-3D-CSI bei Patienten mit Hinterwandinfarkt. Damit konnten erstmalig spulenferne Myokardareale (Hinterwand) hinsichtlich Veränderungen im Metabolismus erfasst werden. Veränderte PCr/γATP-ratios wurden bei Infarktpatienten gegenüber einem Kollektiv herzgesunder Probanden gefunden. Eine exakte Lokalisation der untersuchten Infarkte und damit eine Validierung der spektroskopischen Datenanalyse wurden durch den Vergleich mit den simultan aufgenommenen Late Enhancement Bildern möglich. Damit eröffnet sich in Verbindung mit zunehmend zur Verfügung stehenden Hochfeldgeräten (3T und mehr) für die MRS der Weg zu einem wichtigen klinischen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen. N2 - 31P-MRS is currently the only available non-invasive method for examination of the heart metabolism without radioactive tracers. MRS allows insights in the energetics of ischemic heart disease, heart attack, hypertrophic cardiomyopathy or other cardiac defects. Furthermore this method can also be used for monitoring the treatment success of these aforementioned diseases. Currently MRS is only applied in research because of low reproducibility, low spatially and temporary resolution. Introduction of MR-systems with higher fields, 3 and 7 Tesla, will probably allow optimization of resolution and reproducibility for an integration of 31P-MRS in the clinical diagnostics. The present dissertation deals with methodic development, standardization of MRS and a direct comparison of MR-tomographic (late enhancement) and MR-spectroscopic techniques for detection of cardiac infarction. The significance of 31P-MRS with regards to the localization of the cardiac infarction could be validated by applying simultaneously MRS and late enhancement, a procedure which is already established in clinical diagnostics of cardiac infarction. A major benefit of MRS compared with late enhancement is the possibility to detect pathological changes of the metabolism in areas like remote, stunned or hibernating myocardium very early. These do not demarcate in late enhancement images. By establishing a segmentation algorithm very low variabilities could be achieved within the used quantification program (“SLOOP”). In addition we succeeded in reducing the postprocessing of MRS. As a clinical application, the cardiac metabolism of patients with cardiac infarction of the posterior wall was determined by using acquisition-weighted 31P-3D-CSI. For the first time this resulted in findings of changes of metabolism in myocard remotely from the coil (posterior wall). Altered PCr/γATP-ratios were found in patients with cardiac infarction compared to a collective of healthy volunteers. It was possible to get an exact localization of the cardiac infarction and to validate the spectroscopic data analysis by comparison with simultaneously acquired late enhancement images. Thus, MRS may become an important diagnostic tool for determination of prognostic factors in cardiac diseases due to an increasing availability of high field strength MRI systems (3 Tesla and more). KW - NMR-Spektroskopie KW - Herzinfarkt KW - MR-Spektroskopie KW - 31P-MRS KW - Herzinfarkt KW - Herzmetabolismus KW - mr spectroscopy KW - 31P-MRS KW - cardiac infarction KW - heart metabolism Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-35643 ER - TY - THES A1 - Reiß-Zimmermann, Martin T1 - Entwicklung und Erprobung eines standardisierten Auswerteverfahrens für die Bestimmung der Myokardperfusion mit der MRT T1 - Development and evaluation of a standardized evaluation process for determination of myocardial perfusion by using MRI N2 - Mit dem hier vorgestellten Untersuchungs- und Auswertealgorithmus konnte die Myokardperfusion weitgehend automatisiert semiquantitativ und quantitativ bestimmt werden. Dafür wurden zunächst die Bilddaten segmentiert und in Signalintensitäts-Zeit-Kurven transferiert. Durch eine Basislinien- und Kontaminationskorrektur wurden Artefakte minimiert. Mit Anwendung des Parallel-Bildgebungs-Verfahrens Auto-SENSE konnte zusätzlich eine Erhöhung der Schichtanzahl erreicht werden. Durch die angewendete Basislinienkorrektur konnten Inhomogenitäten verringert werden, welche durch Verwendung einer Oberflächenspule methodenbedingt auftreten. Partialvolumeneffekte, die durch die Morphologie des Herzens insbesondere basis- und spitzennah auftraten, führten durch eine Mischung aus KM-Anflutung im Myokard und Kontamination aus dem Ventrikellumen zu einer Beeinflussung der Perfusionsergebnisse. Durch die Verwendung der vorgestellten Kontaminationskorrektur konnten diese Artefakte erheblich minimiert werden. Die so errechneten Perfusionswerte korrelierten gut mit den in der Literatur angegebenen Daten, welche sowohl in tierexperimentellen als auch Probanden- und auch Patientenstudien mit unterschiedlichen Modalitäten ermittelt wurden. Eine regionale Heterogenität konnte nicht signifikant nachgewiesen werden. Molekular-physiologische Untersuchungen legen zwar nahe, dass es diese Heterogenität gibt, die regionale Verteilung der Perfusion wird jedoch kontrovers und noch keinesfalls abschließend in der Literatur diskutiert. Durch Anwendung von Auto-SENSE konnte mit einer Erhöhung der Schichtanzahl bei gleichbleibender Schichtdicke das gesamte linksventrikuläre Myokard untersucht werden. Trotz verringertem SNR waren die Ergebnisse vergleichbar mit der konventionellen Turbo-FLASH-Technik. Ob das Potential der Parallelbildgebung für eine Abdeckung des gesamten Herzens oder für eine höhere Auflösung von 3-4 Schichten pro Untersuchungen genutzt werden soll, ist in der aktuellen Literatur noch Gegenstand der Diskussion. Die hochaufgelösten Untersuchungen scheinen jedoch derzeit vorteilhafter aufgrund geringerer Partialvolumeneffekte sowie der besseren Beurteilbarkeit einer subendokardialen Zone und eines transmuralen Perfusionsgradienten. Die MR-Perfusionsbildgebung ist ein aktives und rasch wachsendes Gebiet innerhalb der kardialen Bildgebung mit großem Entwicklungspotential. Durch Einbindung in ein umfassendes Herz-MR-Untersuchungsprotokoll (z.B. Morphologie, Kinetik, evtl. MR-Koronarangiographie) ist in einem Untersuchungsgang eine umfassende Diagnostik bei Patienten mit Verdacht auf KHK möglich. N2 - Using the presented algorithm for examination and analysis, a nearly fully automated quantitative and semi-quantitative assessment of myocardial perfusion had been performed. In a first step image data had been segmented and transformed into signal intensity time curves. Auto-SENSE, being a parallel imaging method, enabled increment of the amount of slices. Applying the proposed baseline and contamination correction had minimized artifacts. Baseline correction also minimized inhomogeneities that are caused by using surface coils. Partial volume effects, which had been seen especially in the basis and apex of the heart, lead to interference of the myocardial perfusion due to interaction of the myocardial enhancement and contamination of the lumen of the ventricle. Using the proposed contamination correction largely minimized these artifacts. The achieved myocardial perfusion results correspond well with literature data, which had been determined in animal and human studies using different modalities. We did not find a regional heterogeneity in myocardial perfusion, which is being discussed controversially in literature. Due to applying Auto-SENSE, examination of the whole left ventricular myocardium had been performed by increasing the amount of slices, while thickness of every single slice stayed even. Despite decrease of SNR, perfusion results had been equal to conventional Turbo-FLASH technique. Whether the potential of parallel imaging should be used for evaluation of the whole heart or higher resolution of 3-4 slices per examination is being discussed controversially in recent literature. High-resolution examinations seem to be advantageous due to reduced partial volume effects as well as better discrimination of the subendocardial zone and a transmural perfusion gradient. MR imaging of the cardial perfusion is an active and fast growing field of research in cardiac imaging with a large developmental potential. Integration in a cardiac MR protocol (for example morphology, kinetics, optional MR-coronary angiography) enables a comprehensive diagnostic tool in a single examination for patients with suspected cardiac heart disease. KW - NMR-Tomographie KW - Herz KW - Bildgebendes Verfahren KW - Koronarperfusion KW - Herzmuskel KW - Auswertung KW - Entwicklung KW - MRI KW - heart KW - myocardial perfusion Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-34560 ER - TY - JOUR A1 - Reichel, Thomas A1 - Herz, Stefan A1 - el Tabbakh, Mohammed A1 - Bley, Thorsten Alexander A1 - Plumhoff, Piet A1 - Rueckl, Kilian T1 - Less than 9.5-mm coracohumeral distance on axial magnetic resonance imaging scans predicts for subscapularis tear JF - JSES International N2 - Background Diagnosis of subscapularis (SSC) tendon lesions on magnetic resonance imaging (MRI) can be challenging. A small coracohumeral distance (CHD) has been associated with SSC tears. This study was designed to define a specific threshold value for CHD to predict SSC tears on axial MRI scans. Methods This retrospective study included 172 shoulders of 168 patients who underwent arthroscopic surgery for rotator cuff tear or glenohumeral instability. Diagnostic arthroscopy confirmed an SSC tear in 62 cases (36.0%, test group a), rotator cuff tear tears other than SSC in 71 cases (41.3%, control group b) and glenohumeral instability without any rotator cuff tear in 39 cases (22.7%, zero-sample group c). All patients had a preoperative MRI of the shoulder (1.5T or 3T). Minimum CHD was measured on axial fat-suppressed proton density-, T2-, or T1-weigthed sequences. Receiver operating characteristics analysis was used to determine the threshold value for CHD, and sensitivity and specificity were calculated. Results CHD measurement had a good interobserver reliability (Intraclass correlation coefficient 0.799). Mean CHD was highly significantly (P < .001) less for test group a (mean 7.3 mm, standard deviation ± 2.2) compared with control group b (mean 11.1 mm, standard deviation ± 2.3) or zero-sample group c (mean 13.6 mm, standard deviation ± 2.9). A threshold value of CHD <9.5 mm had a sensitivity of 83.6% and a specificity of 83.9% to predict SSC tears. Conclusion A CHD <9.5 mm on MRI is predictive of SSC lesions and a valuable tool to diagnose SSC tears. KW - subscapularis tear KW - coracohumeral distance KW - rotator cuff tear KW - coracohumeral impingement Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-259118 VL - 5 IS - 3 ER - TY - THES A1 - Reguillo, Francisco J. J. T1 - Organfilter in der konventionellen Röntgendiagnostik und ihre Bedeutung für den Strahlenschutz T1 - Organ filters in conventional x-ray diagnostics and their importance for radiation protection N2 - Die vorliegende Arbeit untersucht den Effekt von Organfiltern insbesondere auf die Dosis. Im Rahmen dieser Untersuchung wurde die Dosis in Form des Flächendosisproduktes (FDP) gemessen. Filter bewirken nicht nur eine Verbesserung der Objektdarstellung in den normalerweise zu stark geschwärzten Randpartien, sondern auch eine Dosisreduktion, d.h. die Organfilter sind gut geeignet, den Strahlenschutz positiv zu beeinflussen. Dieser Effekt der Dosisreduktion war bei den Keilfiltern (Mittel- und Vorfuß sowie HWS) weniger deutlich als bei den für Schädel und Schulter angewendeten Filtern. N2 - This dissertation examines the impact of organ filters particularly with regard to the dosage. Within this framework the dose was quantified in terms of the dose-area product (DAP). Filters not only cause a better object presentation in the normally overexposed border areas but also a dose reduction. Thus, it appears that organ filters are suitable to improve the radiation protection. The effect of dose reduction was more distinctive with filters used for craniums and shoulders than with wedge filters (metatarsus, forefoot and cervical spine). KW - Strahlenschutz KW - Organfilter KW - Strahlenschutz KW - Dosisreduktion KW - organ filters KW - radiation protection KW - dose reduction Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-24130 ER - TY - JOUR A1 - Rasche, Leo A1 - Kumar, Manoj A1 - Gershner, Grant A1 - Samant, Rohan A1 - Van Hemert, Rudy A1 - Heidemeier, Anke A1 - Lapa, Constantin A1 - Bley, Thorsten A1 - Buck, Andreas A1 - McDonald, James A1 - Hillengass, Jens A1 - Epstein, Joshua A1 - Thanendrarajan, Sharmilan A1 - Schinke, Carolina A1 - van Rhee, Frits A1 - Zangari, Maurizio A1 - Barlogie, Bart A1 - Davies, Faith E. A1 - Morgan, Gareth J. A1 - Weinhold, Niels T1 - Lack of Spleen Signal on Diffusion Weighted MRI is associated with High Tumor Burden and Poor Prognosis in Multiple Myeloma: A Link to Extramedullary Hematopoiesis? JF - Theranostics N2 - Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM. KW - multiple myeloma KW - diffusion weighted mri KW - spleen KW - tumor burden KW - high risk KW - extramedullary hematopoiesis Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-224982 VL - 9 IS - 16 ER - TY - THES A1 - Rapf, Katrin T1 - Perfusionsuntersuchungen des Herzens nach Myokardinfarkt mittels Magnetresonanztomographie T1 - Examinations of myocardial perfusion after myocardial infarction by MRI N2 - Das Hauptziel der vorliegenden Arbeit war es, eine genauere Erkenntnis über die derzeitigen Möglichkeiten der quantitativen Messung der myokardiale Perfusion im Hinblick auf die Beschreibung verschiedener myokardialer Infarkte mittels kardialer MRT zu gewinnen. Die Untersuchungen zur Perfusion im Infarktgebiet ergaben, dass ein visuell festgestellter subendokardialer Infarkt an Hand der Bestimmung der absoluten Perfusion nicht immer nachvollzogen werden konnte. Ein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Höhe der absoluten Perfusion im Infarktgebiet konnte nicht gezeigt werden. Die Untersuchungen zur Perfusion im Remote Myokard ergaben keinen Zusammenhang zwischen der Perfusion im Remote Myokard und dem transmuralen Ausmaß des no-reflow-Phänomens in der First Pass Perfusion. Auch korrelierte die Perfusion im Remote Myokard nicht mit dem Auftreten eines no-reflow Phänomens im Late Enhancement. Die Perfusion im Remote Myokard unterschied sich zwischen transmuralen und nicht-transmuralen Infarkten. Eine Hyperperfusion im Remote Myokard konnte erst ab einer Infarktausdehnung von 75% im Late Enhancement beobachtet werden, während eine Hypoperfusion im Remote Myokard bei allen Infarktausdehnungen zwischen 0% und 100% auftrat. Die Untersuchungen zur Perfusion bei Vorliegen eines transmuralen Infarktes“ ergaben eine signifikante Korrelation der Perfusionen in Infarktgebiet und Remote Myokard bei transmuralem Infarkten. Die Ergebnisse zur Messung der Perfusion in Abhängigkeit von der relativen Infarktgröße wiesen keinen Zusammenhang zwischen der Perfusion im Infarktgebiet und der relativen Infarktgröße auf. Ebenso konnte keine Beziehung zwischen der Perfusion im Remote Myokard und der relativen Infarktgröße dargelegt werden. Letztendlich wurde das Verhalten der quantitativen Perfusion im Infarktgebiet und im Remote Myokard in Abhängigkeit von der Zeit nach Infarktereignis untersucht. Dabei zeigte sich kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Infarktgebiet zwischen der Erst- und der Spätuntersuchung. Ebenso war kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Remote Myokard zwischen der Erst- und der Spätuntersuchung erkennbar. Die kardiale MRT ist aufgrund der gleichzeitigen Analyse von morphologischen, funktionellen, quantitativen und metabolischen Parametern in einem Untersuchungsgang ein erfolgversprechendes Bildgebungsverfahren der Zukunft, da sie nicht invasiv ist, ohne Einsatz von Röntgenstrahlung auskommt und dabei eine gute räumliche Auflösung bei hohem Gewebekontrast bietet. Studien zeigen, dass die Kombination von Stress-Perfusion und Late-Technik in einem MRT-Protokoll eine höhere Genauigkeit als die Verwendung der SPECT-Untersuchung in der klinischen Beurteilung von Koronargefäßstenosen und im Nachweis subendokardialer Infarkte aufweist. 62 Allerdings erfährt die in vorliegender Arbeit verwendete Technik der Datenverarbeitung in dieser Form ohne Zweifel noch ihre Limitation im klinischen Alltag. Grundsätzlich ist zu sagen, dass die Messung der absoluten Perfusion im Myokard mit der MRT des Herzens zurzeit sicherlich noch nicht ausgereift ist. Dennoch lassen die in dieser Arbeit vorgestellten Ergebnisse und die viel versprechende Weiterentwicklung in der magnetresonanztomographischen Bildgebung weit reichende und interessante Möglichkeiten erahnen. N2 - The aim of this work was to provide a more precise knowledge of the current possibilities for the quantitative measurement of myocardial perfusion in terms of the description of various myocardial infarcts using cardiac MRI. The analysis regarding the determination of a subendokardial infarction using the absolute perfusion in this area showed that the location of the infarction could not always been reproduced. A correlation between the occurrence of a no-reflow in Late Enhancement and the level of absolute perfusion in the area of infarction could not be shown. The analysis on the remote myocardial perfusion showed no coherence between myocardial perfusion in remote and the transmural extent of the no-reflow phenomenon in First-pass perfusion. Also the myocardial perfusion in remote myocardium did not correlate with the occurrence of a no-reflow phenomenon in Late Enhancement. The perfusion in remote myocardium differed between transmural and non-transmural infarctions. A hyperperfusion in remote myocardium was only seen with an extent of infarction of 75% and more in Late Enhancement while a hypoperfusion in remote myocardium occured with all infarction extents between 0% and 100%. The analysis regarding the perfusion when there was a transmural infarction showed a significant correlation of the perfusions in the area of infarcation and the remote myocardium. The results for the measurement of perfusion depending on the relative size of the infarction showed no coherence between the perfusion in the area of the infarction and relative size of it. Also there was no way of showing coherence between the myocardial perfusion in remote myocardium and the relative size of the infarction. Finally the behaviour of quantitative perfusion in the area of infarction and in the remote myocardium was investigated. The results showed no coherence between the occurrence of a no-reflow phenomenon in late enhancement and the development of the perfusion in the area of infarction between the first and the late data ascertainment. Also there was no coherence between the occurrence of a no-reflow in late enhancement and the development of the remote myocardium perfusion in between the first and the late data ascertainment. The cardiac MRI is due to the simultaneous analysis of morphological, functional, quantitative and metabolic parameters during one single investigation a promising imaging procedure of the future, because it is not invasive, without the use of X-rays and requires a good spatial resolution with high tissue contrast. Studies show that the combination of stress perfusion and late-MRI technique provide a higher accuracy in the clinical evaluation of coronary stenosis and subendocardial infarctions than the single use of the SPECT- technique. Without doubt the way of processing data used in this work still comes to its limits in everyday work and the technique of receiving data of the myocardial perfusion using cardiac MRI must still be developed. Nevertheless the results presented in this work and the promising progresses in the field of MRI imaging give a hint to the interesting and far reaching possibilities that are to come. KW - Perfusion KW - NMR-Tomographie KW - Herzinfarkt KW - Herzmuskel KW - MRT KW - Perfusion KW - no reflow KW - akuter Myokardinfarkt KW - late enhancement KW - MRI KW - perfusion KW - no reflow KW - acute myocardial infarction KW - late enhancement Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-27297 ER - TY - THES A1 - Rapf, Christian T1 - Magnetresonanztomographische Untersuchungen des Herzens zur Differenzierung des "no-reflow" Phänomens nach Myokardinfarkt T1 - MRI examinations of the heart for the differentiation of the "no-reflow" phenomenon after myocardial infarction N2 - Ziel der vorliegenden Arbeit war es, einen genaueren Aufschluss über die Erfassung der mikrovaskulären Integrität von Myokardinfarkten nach erfolgreicher koronarer Revaskularisierung mittels kardialer MR-Bildgebungstechniken zu geben. Dazu wurde zuerst das Auftreten des „no-reflow“ in der FPP und im LE sowie zu verschiedenen Zeitintervallen untersucht. Die Untersuchungen hierzu ergaben ein häufigeres Auftreten des „no-reflow“ in den FPP-Untersuchungen und eine Abnahme des beobachtbaren „no-reflow“, je später die Untersuchung nach Kontrastmittelgabe erfolgte. Zusätzlich zeigte sich, dass das Auftreten eines „no-reflow“ in der LE-Untersuchung immer mit einem Auftreten in der FPP einherging. Weiterhin wurden die Auswirkungen des Infarktausmaßes auf das „no-reflow“ überprüft. Bei den Untersuchungen wurde zwischen Infarktvolumen und transmuraler Infarktgröße unterschieden. Dabei zeigte sich, dass das Auftreten eines „no-reflow“ in der FPP- und LE-Untersuchung besser mit dem relativen Infarktvolumen als mit dem transmuralen Infarktausmaß korrelierte. Infarkte mit einem relativen Volumen kleiner neun Prozent ließen kein „no-reflow“ im LE beobachten, wobei bei einem Infarktvolumen > 15 % ein „no-reflow“ sowohl in der FPP- als auch in der LE-Untersuchung beobachtbar war. Die Untersuchungen zum transmuralen Infarktausmaß zeigten, dass ein „no-reflow“ auch bei nicht transmuralen Infarkten auftrat. Daneben konnte beobachtet werden, dass auch transmurale Infarkte ohne „no-reflow“ auftreten. Des Weiteren wurden die Auswirkungen eines beobachtbaren „no-reflow“ auf die EF überprüft. Die EF wurde hierzu 14 Tage und drei Monate nach Myokardinfarkt bestimmt und mit dem „no-reflow“ in der FPP und im LE der Erstuntersuchung verglichen. Hierbei zeigten zum ersten Untersuchungszeitpunkt in der FPP-Untersuchung mehr als 50 % der Infarkte sowohl bei einer EF < 55 % als auch bei einer EF > 55 % ein „no-reflow“. Dagegen war in der LE-Untersuchung bei einer EF < 55 % kein Unterschied bezüglich der Beobachtung eines „no-reflow“ feststellbar, während bei einer EF > 55 % über 70 % der Infarkte kein „no-reflow“ aufwiesen. In der „Untersuchung nach drei Monaten“ zeigten in der FPP-Untersuchung bei einer EF < 55 % knapp 75 % der Infarkte ein „no-reflow“, während es bei einer EF > 55 % ungefähr 25 % waren. In der LE-Untersuchung war, ähnlich dem ersten Untersuchungszeitpunkt, bei einer EF < 55 % kein wesentlicher Unterschied festzustellen, wohingegen bei einer EF > 55 % über 75 % der Infarkte kein beobachtbares „no-reflow“ im LE zeigten. Für die FPP- und LE-Untersuchung ergab sich bei beiden Untersuchungszeitpunkten kein statistischer signifikanter Unterschied bezüglich der EF der Patienten, die „no-reflow“ zeigten, zu den Patienten, die kein „no-reflow“ zeigten. Ohne Zweifel ist die kardiale MRT aufgrund des nichtinvasiven dreidimensionalen Charakters und des guten Gewebekontrastes ohne Einsatz von Röntgenstrahlung ein viel versprechendes bildgebendes Verfahren der Zukunft. Der Vorteil der Anwendung dieses Verfahrens bei Patienten mit Myokardinfarkt ist die präzise Bewertung des transmuralen Ausmaßes der myokardialen Nekrose sowie des „no-reflow“ und die gleichzeitige Erfassung der Herzfunktionsparameter. Der Stand der Erfassung und Bewertung des „no-reflow“ in MRT-Bildern reicht jedoch zurzeit noch nicht für den Einsatz in der klinischen Routinediagnostik aus. Die in dieser Arbeit vorgestellten Ergebnisse sollen einen Beitrag für diese Weiterentwicklung leisten. Für einen späteren Standard zur Erfassung der mikrovaskulären Integrität beim Akuten Koronarsyndrom sind jedoch weitere Studien nötig. Hierbei wären genauere Untersuchungen zum Schweregrad des „no-reflow“ sowie zum Auftreten zu verschiedenen Zeitpunkten sinnvoll. Außerdem sollten exaktere Aussagen über die Korrelation des Auftretens des „no-reflow“ und den Herzfunktionsparametern erhoben werden. Es ist anzunehmen, dass sich durch eine Weiterentwicklung der kardialen MRT der Informationsgehalt in Zukunft stetig steigern wird und dadurch eine eindrucksvolle Ergänzung der kardiologischen Differentialdiagnostik sein. Dabei könnte eine multimodale Akquisition der kardialen Makro- und Mikrozirkulation, pathologischer Gewebeveränderungen und myokardialer Funktionsstörungen in einem Untersuchungsgang mit einem kurzen zeitlichen Aufwand erreicht werden. Durch Integration der MRT-Untersuchungen zum „no-reflow“ in den klinischen Alltag könnte somit eine Bestimmung des individuellen Risikos sowie ein risikoadaptiertes Behandlungskonzept erreicht werden. N2 - The aim of this work was to provide a clear overview of the acquisition of microvascular integrity of myocardial infarction after successful coronary revascularization using cardiac MR imaging techniques. At first the occurrence of the "no-reflow" in the FPP and the LE and at different time intervals was investigated. The investigations showed a more frequent occurrence of "no-reflow" in the FPP studies and an increase of the observable "no-reflow" the later the investigation after application of contrast medium is done. Further could be showed that the occurrence of a "no-reflow" in LE always relates with an occurrence in FPP. Beyond the impact of the size of the infarction on the "no-reflow" was verified. The investigation distinguished between volume of infarction and extension of infarction. The results were that the occurrence of a "no-reflow" in FPP-and LE correlates better with the relative volume of infarction than with transmural extension of infarction. Infarcts with a relatively small volume of nine percent had no "no-reflow" in LE, while at a volume of infarction > 15% "no-reflow" in FPP as well in LE were observable. The investigations to transmural extension of infarction showed that "no-reflow" as well appears in non transmural infarction. Additional to that, transmural infarcts without "no-reflow" were also seen. Furthermore the effects of an observable "no-reflow" on the EF were investigated. For this purpose the EF was determinated 14 days and three months after myocardial infarction and was compared with the occurrence of "no-reflow" in FPP and LE of the initial investigation. At this juncture for the first time of investigation showed "no-reflow" in FPP more than 50% of infarcts both at EF <55% and at EF> 55%. On the other hand, in the investigation of LE was at EF <55% no difference in the observation of "no-reflow" detectable, while at EF> 55% over 70% of infarcts didn’t show "no-reflow”. The "investigation after three months" showed in FPP at EF <55% just under 75% of infarcts "no-reflow", while at EF> 55% about 25% showed “no-reflow”. In the investigation of LE was similar to the first time of the investigation: at EF <55% no significant difference was noted, while at EF> 55% over 75% of infarcts didn’t show "no-reflow" in LE. For the investigations of FPP-and LE resulted in both times of investigation no statistical significant difference in EF of patients, who showed "no-reflow" compared to patients who didn’t showed "no-reflow". There’s no doubt the Cardiac MRI is because of the three-dimensional non-invasive nature and good contrast of tissue without the use of X-rays a promising imaging technique of the future. The advantage in using this operation in patients with myocardial infarction is the accurate transmural assessment of extent of myocardial necrosis, as well as "no-reflow" and the simultaneous detection of parameters of cardiac function. The state of acquisition and evaluation of "no-reflow" in MRI images is actually not sufficient for use in clinical routine diagnostics. The presented results of this work should contribute to this development. However, to meet a standard for acquisition and assessment of microvascular integrity of myocardial infarction further studies are needed. For these purposes more accurate studies on the severity of "no-reflow" and the appearance at different times would be useful. Furthermore accurate statements about the correlation of the incidence of "no-reflow" and cardiac function parameters should be collected. It is to be accepted that by a further development of cardiac MRI, the information content in the future will steadily increase and thus an impressive complement of cardiac differential diagnosis will be possible. At this juncture a multi-modal acquisition of cardiac macro-and micro-circulation, pathological tissue changes and myocardial dysfunction in an investigation course with a short time effort could be achieved. By integrating the MRI examinations to the "no-reflow" in the clinical routine a provision of individual risk and a risk adapted treatment concept could be achieved. KW - NMR-Tomographie KW - Herzinfarkt KW - MRT KW - mikrovaskuläre Obstruktion KW - no reflow KW - first pass KW - late enhancement KW - MRI KW - microvascular obstruction KW - no reflow KW - acute myocardial infarction KW - enhancement Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-25811 ER - TY - THES A1 - Portmann, Johannes T1 - Accelerated inversion recovery MRI of the myocardium using spiral acquisition T1 - Beschleunigte Inversion-Recovery MR-Bildgebung des Myokards mit spiralen Auslesezügen N2 - This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality. N2 - Diese Arbeit behandelt die Beschleunigung der kardiovaskulären MRT zum Erfassen funktioneller Information bei Steady-State-Kontrast und zur Unter- suchung der Vitalität bei Wiederherstellung der Magnetisierung nach ihrer Inversion. Zwei Ansätze werden eingeführt und im Detail diskutiert: MOCO- MAP, welches ein exponentielles Modell nutzt, um dynamische Daten zu rekonstruieren, und IR-CRISPI, welches mit seinem “low-rank plus sparse"- Algorithmus mit Compressed Sensing verwandt ist. MOCO-MAP ist der Nachfolger der modellbasierten Beschleunigung des Parameter-Mappings (MAP) für die Anwendung im Bereich des Myokards. Hierzu wurde es mit einer Bewegungskorrektur (MOCO) versehen, um expo- nentielles Fitten eines unbewegten Objects in Zeitrichtung zu ermöglichen. Das Einbringen dieses physikalischen Vorwissens zusammen mit dem Erzwin- gen von Konsistenz mit den Messdaten wird dazu genutzt, iterativ eine Bildfolge aus Daten einer deutlich kürzeren Messung als herkömmlich zu rekonstruieren (< 3 s gegenüber ca. 10 s). Die Ergebnisse zeigen die Umsetz- barkeit der Methode sowie die Nachweisbarkeit von Delayed Enhancements im Myokard, aber deutliche funktionelle Abweichungen und Artefakte bereits aufgrund von kleinen Ungenauigkeiten der Bewegungskorrektur. IR-CRISPI geht aus CRISPI hervor, welches zur Auswertung von funk- tionellen Echtzeitdaten bei konstantem Kontrast dient. Mit der Rekon- struktion durch getrennte Berechnung von niedrigrangigem und dünnbe- setztem Matrixanteil wird hier bei der Datenrekonstruktion weniger stark eingeschränkt als bei einem strikten exponentiellen Modell. Die pirale Auf- nahmeweise erlaubt hierzu ausreichend effiziente k-Raumabdeckung. Die “low-rank plus sparse"-Rekonstruktion ist kompatibel mit dynamischen und mit Inversion-Recovery-Daten. Eine Bewegungskorrektur ist folglich nicht nötig. IR-CRISPI wurde mit einer Rauschunterdrückung durch räumliche Wavelet- Filterung versehen. Eine Studie, die 10 Patienten einschließt, zeigt die Eignung für die medizinische Anwendung. Der Vergleich mit herkömm- lichen Aufnahmetechniken lässt auf den gewonnenen diagnostischen Nutzen schließen. Besonders für Patienten, die Schwierigkeiten mit dem Luftanhal- ten haben, eröffnet diese Echtzeitaufnahmemethode eine wertvolle Alterna- tive und erhöhte Stabilität. Am Ende konnte gerade mittels IR-CRISPI eine bemerkenswerte Beschleu- nigung der kardiovaskulären MR-Untersuchung verwirklicht werden. Trotz der kurzen Aufnahmezeit von weniger als 100 s für den kompletten linken Ven- trikel schließt es nicht nur die Information zweier herkömmlicher Protokolle mit ein (Cine und LGE), die zusammen mehr als 9,6 min dauern, sondern es erlaubt zusätzlich auch das Einstellen der TI-Zeit im Nachhinein und liefert Ergebnisse mit geringerem Artefaktlevel bei ähnlicher Bildqualität KW - Kernspintomografie KW - Herzfunktion KW - Herzmuskel KW - Bildgebendes Verfahren KW - Echtzeit KW - cine loop KW - late enhancement KW - late gadolinium-enhancement KW - magnetic resonance imaging KW - real-time imaging KW - spiral trajectory Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-302822 ER - TY - JOUR A1 - Pietro-Garcia, Christian A1 - Hartmann, Oliver A1 - Reissland, Michaela A1 - Fischer, Thomas A1 - Maier, Carina R. A1 - Rosenfeldt, Mathias A1 - Schülein-Völk, Christina A1 - Klann, Kevin A1 - Kalb, Reinhard A1 - Dikic, Ivan A1 - Münch, Christian A1 - Diefenbacher, Markus E. T1 - Inhibition of USP28 overcomes Cisplatin-resistance of squamous tumors by suppression of the Fanconi anemia pathway JF - Cell Death and Differentiation N2 - Squamous cell carcinomas (SCC) frequently have an exceptionally high mutational burden. As consequence, they rapidly develop resistance to platinum-based chemotherapy and overall survival is limited. Novel therapeutic strategies are therefore urgently required. SCC express ∆Np63, which regulates the Fanconi Anemia (FA) DNA-damage response in cancer cells, thereby contributing to chemotherapy-resistance. Here we report that the deubiquitylase USP28 is recruited to sites of DNA damage in cisplatin-treated cells. ATR phosphorylates USP28 and increases its enzymatic activity. This phosphorylation event is required to positively regulate the DNA damage repair in SCC by stabilizing ∆Np63. Knock-down or inhibition of USP28 by a specific inhibitor weakens the ability of SCC to cope with DNA damage during platin-based chemotherapy. Hence, our study presents a novel mechanism by which ∆Np63 expressing SCC can be targeted to overcome chemotherapy resistance. Limited treatment options and low response rates to chemotherapy are particularly common in patients with squamous cancer. The SCC specific transcription factor ∆Np63 enhances the expression of Fanconi Anemia genes, thereby contributing to recombinational DNA repair and Cisplatin resistance. Targeting the USP28-∆Np63 axis in SCC tones down this DNA damage response pathways, thereby sensitizing SCC cells to cisplatin treatment. KW - USP28 KW - Cisplatin KW - squamous tumors Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-273014 SN - 1476-5403 VL - 29 IS - 3 ER - TY - JOUR A1 - Petritsch, Bernhard A1 - Pannbecker, Pauline A1 - Weng, Andreas M. A1 - Grunz, Jan-Peter A1 - Veldhoen, Simon A1 - Bley, Thorsten A. A1 - Kosmala, Aleksander T1 - Split-filter dual-energy CT pulmonary angiography for the diagnosis of acute pulmonary embolism: a study on image quality and radiation dose JF - Quantitative Imaging in Medicine and Surgery N2 - Background: Computed tomography (CT) pulmonary angiography is the diagnostic reference standard in suspected pulmonary embolism (PE). Favorable results for dual-energy CT (DECT) images have been reported for this condition. Nowadays, dual-energy data acquisition is feasible with different technical options, including a single-source split-filter approach. Therefore, the aim of this retrospective study was to investigate image quality and radiation dose of thoracic split-filter DECT in comparison to conventional single-energy CT in patients with suspected PE. Methods: A total of 110 CT pulmonary angiographies were accomplished either as standard single-energy CT with automatic tube voltage selection (ATVS) (n=58), or as split-filter DECT (n=52). Objective [pulmonary artery CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] and subjective image quality [four-point Likert scale; three readers (R)] were compared among the two study groups. Size-specific dose estimates (SSDE), dose-length-product (DLP) and volume CT dose index (CTDIvol) were assessed for radiation dose analysis. Results: Split-filter DECT images yielded 67.7% higher SNR (27.0 vs. 16.1; P<0.001) and 61.9% higher CNR (22.5 vs. 13.9; P<0.001) over conventional single-energy images, whereas CT attenuation was significantly lower (344.5 vs. 428.2 HU; P=0.013). Subjective image quality was rated good or excellent in 93.0%/98.3%/77.6% (R1/R2/R3) of the single-energy CT scans, and 84.6%/82.7%/80.8% (R1/R2/R3) of the split-filter DECT scans. SSDE, DLP and CTDIvol were significantly lower for conventional single-energy CT compared to split-filter DECT (all P<0.05), which was associated with 26.7% higher SSDE. Conclusions: In the diagnostic workup of acute PE, the split-filter allows for dual-energy data acquisition from single-source single-layer CT scanners. The existing opportunity to assess pulmonary “perfusion” based on analysis of iodine distribution maps is associated with higher radiation dose in terms of increased SSDE than conventional single-energy CT with ATVS. Moreover, a proportion of up to 3.8% non-diagnostic examinations in the current reference standard test for PE is not negligible. KW - dual-energy KW - CT-angiography KW - vascular KW - pulmonary arteries KW - embolism/thrombosis Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-231456 VL - 11 IS - 5 ER - TY - JOUR A1 - Petritsch, Bernhard A1 - Köstler, Herbert A1 - Gassenmaier, Tobias A1 - Kunz, Andreas S A1 - Bley, Thorsten A A1 - Horn, Michael T1 - An investigation into potential gender-specific differences in myocardial triglyceride content assessed by \(^{1}\)H-Magnetic Resonance Spectroscopy at 3Tesla JF - Journal of International Medical Research N2 - Objective: Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals. Methods: Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses. Results: In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28% (interquartile range [IQR] 0.17–0.42%) in male and 0.24% (IQR 0.14–0.45%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g). Conclusions: The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers. KW - cardiac KW - magnetic resonance imaging KW - 1H-Magnetic resonance spectroscopy (1H-MRS) KW - myocardium KW - triglycerides KW - metabolism KW - gender Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-168808 VL - 44 IS - 3 ER - TY - JOUR A1 - Petritsch, Bernhard A1 - Goltz, Jan Peter A1 - Hahn, Dietbert A1 - Wendel, Frank T1 - Extensive craniocervical bone pneumatization JF - Diagnostic and Interventional Radiology N2 - We report a case of extensive abnormal craniocervical bone pneumatization accidentally found in a patient without any history of trauma or surgery. The patient had only mild unspecific thoracic pain and bilateral paresthesia that did not correlate with computed tomography findings. KW - vertebral pneumaticity KW - sauropod dinosaurs KW - bone KW - skull KW - cervical vertebrae pneumatization Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-139349 VL - 17 IS - 4 ER - TY - JOUR A1 - Petritsch, Berhard A1 - Kosmala, Aleksander A1 - Weng, Andreas Max A1 - Bley, Thorsten Alexander T1 - Tin-filtered 100kV ultra-low-dose CT of the paranasal sinus: initial clinical results JF - PLoS ONE N2 - Objectives To investigate the feasibility, diagnostic image quality and radiation dose of 3\(^{rd}\) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. Methods We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scanprotocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). Results All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. Conclusions Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases. KW - Computed axial tomography KW - Inflammatory diseases KW - Radiation exposure KW - Diagnostic medicine KW - Fats KW - Mastoid process KW - X-ray radiography KW - Soft tissues Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-204127 VL - 14 IS - 5 ER - TY - JOUR A1 - Pennig, Lenhard A1 - Hoyer, Ulrike Cornelia Isabel A1 - Krauskopf, Alexandra A1 - Shahzad, Rahil A1 - Jünger, Stephanie T. A1 - Thiele, Frank A1 - Laukamp, Kai Roman A1 - Grunz, Jan-Peter A1 - Perkuhn, Michael A1 - Schlamann, Marc A1 - Kabbasch, Christoph A1 - Borggrefe, Jan A1 - Goertz, Lukas T1 - Deep learning assistance increases the detection sensitivity of radiologists for secondary intracranial aneurysms in subarachnoid hemorrhage JF - Neuroradiology N2 - Purpose To evaluate whether a deep learning model (DLM) could increase the detection sensitivity of radiologists for intracranial aneurysms on CT angiography (CTA) in aneurysmal subarachnoid hemorrhage (aSAH). Methods Three different DLMs were trained on CTA datasets of 68 aSAH patients with 79 aneurysms with their outputs being combined applying ensemble learning (DLM-Ens). The DLM-Ens was evaluated on an independent test set of 104 aSAH patients with 126 aneuryms (mean volume 129.2 ± 185.4 mm3, 13.0% at the posterior circulation), which were determined by two radiologists and one neurosurgeon in consensus using CTA and digital subtraction angiography scans. CTA scans of the test set were then presented to three blinded radiologists (reader 1: 13, reader 2: 4, and reader 3: 3 years of experience in diagnostic neuroradiology), who assessed them individually for aneurysms. Detection sensitivities for aneurysms of the readers with and without the assistance of the DLM were compared. Results In the test set, the detection sensitivity of the DLM-Ens (85.7%) was comparable to the radiologists (reader 1: 91.2%, reader 2: 86.5%, and reader 3: 86.5%; Fleiss κ of 0.502). DLM-assistance significantly increased the detection sensitivity (reader 1: 97.6%, reader 2: 97.6%,and reader 3: 96.0%; overall P=.024; Fleiss κ of 0.878), especially for secondary aneurysms (88.2% of the additional aneurysms provided by the DLM). Conclusion Deep learning significantly improved the detection sensitivity of radiologists for aneurysms in aSAH, especially for secondary aneurysms. It therefore represents a valuable adjunct for physicians to establish an accurate diagnosis in order to optimize patient treatment. KW - aneurysms KW - aneurysmal subarachnoid hemorrhage KW - CT angiography KW - deep learning KW - convolutional neural networks Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-308117 SN - 0028-3940 SN - 1432-1920 VL - 63 IS - 12 ER - TY - JOUR A1 - Patzer, Theresa Sophie A1 - Kunz, Andreas Steven A1 - Huflage, Henner A1 - Luetkens, Karsten Sebastian A1 - Conrads, Nora A1 - Gruschwitz, Philipp A1 - Pannenbecker, Pauline A1 - Ergün, Süleyman A1 - Bley, Thorsten Alexander A1 - Grunz, Jan-Peter T1 - Quantitative and qualitative image quality assessment in shoulder examinations with a first-generation photon-counting detector CT JF - Scientific Reports N2 - Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDI\(_{vol}\) = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as “non-UHR”. Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ\(_{50}\) = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2–9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58–0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine. KW - bone KW - musculoskeletal system Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357925 VL - 13 ER - TY - JOUR A1 - Patzer, Theresa Sophie A1 - Kunz, Andreas Steven A1 - Huflage, Henner A1 - Conrads, Nora A1 - Luetkens, Karsten Sebastian A1 - Pannenbecker, Pauline A1 - Paul, Mila Marie A1 - Ergün, Süleyman A1 - Bley, Thorsten Alexander A1 - Grunz, Jan-Peter T1 - Ultrahigh-resolution photon-counting CT in cadaveric fracture models: spatial frequency is not everything JF - Diagnostics N2 - In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDI\(_{vol}\) 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1–3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732–0.848; p < 0.001) and fracture assessability (0.880; 0.842–0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0–3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise. KW - photon-counting KW - tomography KW - X-ray computed KW - fracture KW - cancellous bone KW - convolution kernel Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-319281 SN - 2075-4418 VL - 13 IS - 10 ER - TY - THES A1 - Pannenbecker, Pauline Luisa T1 - Vergleich von Dual- und Single-Source Dual-Energy CT in der Diagnostik der akuten Lungenarterienembolie hinsichtlich Bildqualität und Strahlendosis T1 - Comparison of Dual- and Single-Source Dual-Energy CT for the Diagnosis of Acute Pulmonary Embolism Regarding Image Quality and Radiation Dose N2 - Hintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) können mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik ermöglicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualität sowie der Strahlendosis mit einem etabliertem DS-DECT-Gerät verglichen werden. Material und Methoden: Insgesamt wurden 135 Patienten eingeschlossen, die eine CTPA erhielten: 68 erhielten einen DS-DECT-Scan mit 90/Sn150 kV und 67 einen SF-DECT-Scan mit Au/Sn120 kV. Für beide Protokolle wurden farbkodierte Joddistributionskarten erstellt. Die objektive (CT-Abschwächung in relevanten Gefäßen in HU, Signal-Rausch-Verhältnis (SNR), Kontrast-Rausch-Verhältnis (CNR), perfused blood volume (PBV)) und subjektive Bildqualität (2 Befunder (B), 5-Punkte-Likert-Skala) sowie Dosisparameter wurden erhoben und verglichen. Ergebnisse: Alle CTPAs waren von diagnostischer Qualität. Ihre subjektive Bildqualität wurde in 80,9/82,4% (B1/B2) der DS-DECT und in 77,6/76,1% der SF-DECT als exzellent oder gut bewertet. Die subjektive Bildqualität der Joddistributionskarten der SF-DECT wurde von beiden Befundern als schlechter beurteilt. Die HU-Werte der relevanten Gefäße unterschieden sich nicht signifikant (p>0.05), SNR und CNR der SF-Gruppe waren in zentralen Gefäßen jedoch höher (p<0.05); die PBV-Werte der SF-Gruppe waren teils höher (p<0.05). Alle erhobenen Dosisparameter waren in der SF-Gruppe höher (p<0,05). Konklusion: In der diagnostischen Abklärung eines V.a. eine akute LAE ermöglicht der Einsatz eines Split-Filters an einem Single-Source-CT-Scanner eine Dual-Energy-Untersuchung. Dies geht im Vergleich zu etablierten DS-Scannern jedoch mit einer schlechteren Qualität der Joddistributionskarten und einer höheren Strahlendosis einher. N2 - Background: CT pulmonary angiography (CTPA) has established as reference standard in the diagnostic workup of suspected pulmonary embolism (PE). With dual-energy CT (DECT), iodine maps can help to detect segmental and subsegmental PEs. Next to established dual-source techniques, the use of a split-filter enables DECT acquisition with single-source scanners. This study compared a SF-DECT scanner with an established DS-DECT scanner with regard to image quality and radiation dose. Material and Methods: A total of 135 patients receiving a CTPA were included: 68 received a DS-DECT scan with 90/Sn 150 kV and 67 received a SF-DECT scan with Au/Sn 120 kV. Color-coded iodine-distribution maps were reconstructed for both protocols. Objective (CT attenuation in relevant vessels in HU, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), perfused blood volume (PBV)) and subjective image quality (2 readers (R), 5-point Likert scale) as well as radiation dose parameters were documented and compared. Results: All CTPAs were of diagnostic image quality. Subjective image quality was rated as excellent or good in 80,9/82,4% (R1/R2) of DS-DECT scans and in 77,6/76,1% of SF-DECT scans. Subjective image quality of iodine maps of SF-DECT scans was rated lower by both readers. For objective image quality, CT attenuation in HU of relevant vessels did not differ significantly (p>0.05), while SNR and CNR of central vessels in the SF-collective were significantly higher (p<0.05); some PBV-values of the SF-collective were significantly higher (p<0.05). All assessed radiation dose parameters were significantly higher in the SF-collective (p<0.05). Conclusion: In the diagnostic workup of suspected PE the use of a split-filter enables dual-energy acquisition with a single-source CT scanner. However, this is associated with a lower image quality of iodine maps and a higher radiation dose compared to established DS scanners. KW - Lungenembolie KW - Dual-Source-Computertomographie KW - Computertomografie KW - Strahlendosis KW - Single-Source-Dual-Energy-CT KW - Split-Filter-Dual-Energy-CT KW - Image Quality KW - Bildqualität Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-352064 ER - TY - THES A1 - Oechsner, Markus T1 - Morphologische und funktionelle 1H-Magnetresonanztomographie der menschlichen Lunge bei 0.2 und 1.5 Tesla T1 - Morphological and functional 1H magnetic resonance tomography of the human lung at 0.2 and 1.5 tesla N2 - Das Ziel dieser Arbeit war es, Methoden und Techniken für die morphologische und funktionelle Bildgebung der menschlichen Lunge mittels Kernspintomographie bei Feldstärken von 0,2 Tesla und 1,5 Tesla zu entwickeln und zu optimieren. Bei 0,2 Tesla wurde mittels der gemessenen Relaxationszeiten T1 und T2* eine 2D und eine 3D FLASH Sequenz zur Untersuchung der Lungenmorphologie optimiert. Sauerstoffgestützte Messungen der Relaxationszeiten T1 und T2* sowie eine SpinLabeling Sequenz liefern funktionelle Informationen über den Sauerstofftransfer und die Perfusion der Lungen. Bei 1,5 Tesla wurde die Lungenperfusion mittels MR-Kontrastmittel mit einer 2D und einer 3D Sequenz unter Verwendung der Präbolus Technik quantifiziert. Zudem wurden zwei MR-Navigationstechniken entwickelt, die es ermöglichen Lungenuntersuchungen unter freier Atmung durchzuführen und aus den Daten artefaktfreie Bilder zu rekonstruieren. Diese Techniken können in verschiedenste Sequenzen für die Lungenbildgebung implementiert werden, ohne dass die Messzeit dadurch signifikant verlängert wird. N2 - The purpose of this thesis was to make a contribution to the development of lung MRI. While we developed and implemented new sequences and procedures both in the area of low-field MRI (0.2 Tesla) and 1.5 Tesla, we also took existing technologies into account by modifying and optimizing them for the working conditions at hand. In the process, we focused on techniques for both morphological and functional examination of the lung. Lung scans using an open 0.2 Tesla tomograph were an important component of this. Our first objective was to develop various methods for morphological and functional lung MRI, adapt them to altered conditions and further optimize them. The second objective was to contribute more in-depth research of contrast agent-based quantification of lung perfusion for the clinical standard of 1.5 Tesla. Additionally, we developed navigation methods which allow for scans of the lung under conditions of free breathing and without the use of external measurement devices. KW - NMR-Bildgebung KW - Lunge KW - 0.2 Tesla KW - Sauerstoff KW - Präbolus KW - Perfusion KW - freie Atmung KW - Navigator KW - Bilderzeugung KW - Bildgebendes Verfahren KW - oxygen-enhanced KW - spin labeling KW - contrast-enhanced KW - prebolus KW - free respiration Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-66942 ER - TY - JOUR A1 - Oder, Daniel A1 - Üceyler, Nurcan A1 - Liu, Dan A1 - Hu, Kai A1 - Petritsch, Bernhard A1 - Sommer, Claudia A1 - Ertl, Georg A1 - Wanner, Christoph A1 - Nordbeck, Peter T1 - Organ manifestations and long-term outcome of Fabry disease in patients with the GLA haplotype D313Y JF - BMJ Open N2 - Objectives: The severity of Fabry disease is dependent on the type of mutation in the α-galactosidase A (AgalA) encoding gene (GLA). This study focused on the impact of the GLA haplotype D313Y on long-term organ involvement and function. Setting and participants: In this monocentric study, all participants presenting with the D313Y haplotype between 2001 and 2015 were comprehensively clinically investigated at baseline and during a 4-year follow-up if available. Five females and one male were included. Primary and secondary outcome measures: Cardiac, nephrological, neurological, laboratory and quality of life data. Results: AgalA enzyme activity in leucocytes (0.3±0.9 nmol/min/mg protein (mean±SD)) and serum lyso-Gb3 (0.6±0.3 ng/mL at baseline) were in normal range in all patients. Cardiac morphology and function were normal (left-ventricular (LV) ejection fraction 66±8%; interventricular septum 7.7±1.4 mm; LV posterior wall 7.5±1.4 mm; normalised LV mass in MRI 52±9 g/m2; LV global longitudinal strain −21.6±1.9%) and there were no signs of myocardial fibrosis in cardiac MRI. Cardiospecific biomarkers were also in normal range. Renal function was not impaired (estimated glomerular filtration rate MDRD 103±15 mL/min; serum-creatinine 0.75±0.07 mg/dL; cystatin-c 0.71±0.12 mg/L). One female patient (also carrying a Factor V Leiden mutation) had a transitory ischaemic attack. One patient showed white matter lesions in brain MRI, but none had Fabry-associated pain attacks, pain crises, evoked pain or permanent pain. Health-related quality of life analysis revealed a reduction in individual well-being. At long-term follow-up after 4 years, no significant change was seen in any parameter. Conclusions: The results of the current study suggest that the D313Y genotype does not lead to severe organ manifestations as seen in genotypes known to be causal for classical FD." KW - inherited metabolic disorders KW - Anderson-Fabry Disease KW - D313Y genotype KW - Fabry cardiomyopathy KW - Fabry nephropathy KW - Fabry-associated pain Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-161210 VL - 6 ER - TY - JOUR A1 - Nordbeck, Peter A1 - Beer, Meinrad A1 - Köstler, Herbert A1 - Ladd, Mark E. A1 - Quick, Harald H. A1 - Bauer, Wolfgang R. A1 - Ritter, Oliver T1 - Cardiac catheter ablation under real-time magnetic resonance guidance JF - European Heart Journal N2 - One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical … KW - magnetic resonance Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-125638 VL - 33 IS - 15 ER - TY - JOUR A1 - Neufang, S. A1 - Akhrif, A. A1 - Herrmann, C.G. A1 - Drepper, C. A1 - Homola, G.A. A1 - Nowak, J. A1 - Waider, J. A1 - Schmitt, A.G. A1 - Lesch, K.-P. A1 - Romanos, M. T1 - Serotonergic modulation of 'waiting impulsivity' is mediated by the impulsivity phenotype in humans JF - Translational Psychiatry N2 - In rodents, the five-choice serial reaction time task (5-CSRTT) has been established as a reliable measure of waiting impulsivity being defined as the ability to regulate a response in anticipation of reinforcement. Key brain structures are the nucleus accumbens (NAcc) and prefrontal regions (for example, pre- and infralimbic cortex), which are, together with other transmitters, modulated by serotonin. In this functional magnetic resonance imaging study, we examined 103 healthy males while performing the 5-CSRTT measuring brain activation in humans by means of a paradigm that has been widely applied in rodents. Subjects were genotyped for the tryptophan hydroxylase-2 (TPH2; G-703T; rs4570625) variant, an enzyme specific for brain serotonin synthesis. We addressed neural activation patterns of waiting impulsivity and the interaction between the NAcc and the ventromedial prefrontal cortex (vmPFC) using dynamic causal modeling. Genetic influence was examined via interaction analyses between the TPH2 genotype (GG homozygotes vs T allele carriers) and the degree of impulsivity as measured by the 5-CSRTT. We found that the driving input of the vmPFC was reduced in highly impulsive T allele carriers (reflecting a reduced top-down control) in combination with an enhanced response in the NAcc after correct target processing (reflecting an augmented response to monetary reward). Taken together, we found a high overlap of our findings with reports from animal studies in regard to the underlying cognitive processes, the brain regions associated with waiting impulsivity and the neural interplay between the NAcc and vmPFC. Therefore, we conclude that the 5-CSRTT is a promising tool for translational studies. KW - Clinical Genetics Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-164418 IS - 6 ER - TY - JOUR A1 - Neubauer, Henning A1 - Wirth, Clemens A1 - Ruf, Katharina A1 - Hebestreit, Helge A1 - Beer, Meinrad T1 - Acute Muscle Trauma due to Overexercise in an Otherwise Healthy Patient with Cystic Fibrosis JF - Case Reports in Pediatrics N2 - Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury. KW - Cystic fibrosis Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-123967 VL - 2012 IS - 527989 ER - TY - JOUR A1 - Neubauer, Henning A1 - Morbach, Henner A1 - Schwarz, Tobias A1 - Wirth, Clemens A1 - Girschick, Hermann A1 - Beer, Meinrad T1 - Popliteal Cysts in Paediatric Patients: Clinical Characteristics and Imaging Features on Ultrasound and MRI N2 - Popliteal cysts, or Baker cysts, are considered rare in children and may exhibit particular features, as compared with adults. We studied data from80 paediatric patients with 55 Baker cysts, examined over a period of 7 years, and correlated clinical presentation with findings on ultrasonography and MRI. Prevalence of popliteal cysts was 57% in arthritic knees, 58% with hypermobility syndrome, and 28% without risk factors. Only one patient had a trauma history and showed an ipsilateral cyst. Mean cyst volume was 3.4 mL; cysts were larger in boys. Patients with arthritis had echogenic cysts in 53%. Cyst communication with the joint space was seen in 64% on ultrasonography and 86% on MRI. In conclusion, Baker cysts are a common finding in a clinically preselected paediatric population. Children with Baker cysts should be assessed for underlying arthritis and inherited joint hypermobility, while sporadic Baker cysts appear to be common, as well. KW - Medizin Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-68662 ER - TY - JOUR A1 - Neubauer, Henning A1 - Evangelista, Laura A1 - Morbach, Henner A1 - Girschick, Hermann A1 - Prelog, Martina A1 - Köstler, Herbert A1 - Hahn, Dietbert A1 - Beer, Meinrad T1 - Diffusion-weighted MRI of bone marrow oedema, soft tissue oedema and synovitis in paediatric patients: feasibility and initial experience N2 - Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies. KW - Medizin Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-75521 ER - TY - JOUR A1 - Ness, Thomas A1 - Bley, Thorsten A. A1 - Schmidt, Wolfgang A. A1 - Lamprecht, Peter T1 - The Diagnosis and Treatment of Giant Cell Arteritis JF - Deutsches Ärzteblatt International N2 - Background: Giant cell arteritis (GCA) is the most common systemic vasculitis in persons aged 50 and above (incidence, 3.5 per 100 000 per year). It affects cranial arteries, the aorta, and arteries elsewhere in the body, e.g., in the limbs. Methods: We selectively review the pertinent literature, including guidelines and recommendations from Germany and abroad. Results: The typical symptoms of new-onset GCA are bi-temporal headaches, jaw claudiacation, scalp tenderness, visual disturbances, systemic symptoms such as fever and weight loss, and polymyalgia. The diagnostic assessment comprises laboratory testing (erythrocyte sedimentation rate, C-reactive protein), imaging studies (duplex sonography, high-resolution magnetic resonance imaging, positron-emission tomography), and temporal artery biopsy. The standard treatment is with corticosteroids (adverse effects: diabetes mellitus, osteoporosis, cataract, arterial hypertension). A meta-analysis of three randomized controlled trials led to a recommendation for treatment with methotrexate to lower the recurrence rate and spare steroids. Patients for whom methotrexate is contraindicated or who cannot tolerate the drug can be treated with azathioprine instead. Conclusion: Giant cell arteritis, if untreated, progresses to involve the aorta and its collateral branches, leading to various complications. Late diagnosis and treatment can have serious consequences, including irreversible loss of visual function. KW - systemic vasculitides KW - arteriitis temporal arteriitis KW - erythrocyte sedimentation-rate KW - complication aortic-aneurysm KW - large-vessel vasculitis KW - c-reactive protein KW - polymyalgia-rheomatica KW - corticosteroid treatment KW - double-blind KW - ocular manifestations Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-131676 VL - 110 IS - 21 ER - TY - JOUR A1 - Müller, Sophie A1 - Köhler, Franziska A1 - Hendricks, Anne A1 - Kastner, Carolin A1 - Börner, Kevin A1 - Diers, Johannes A1 - Lock, Johan F. A1 - Petritsch, Bernhard A1 - Germer, Christoph-Thomas A1 - Wiegering, Armin T1 - Brain metastases from colorectal cancer: a systematic review of the literature and meta-analysis to establish a guideline for daily treatment JF - Cancers N2 - Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words “brain”, “metastas*”, “tumor”, “colorectal”, “cancer”, and “malignancy”. In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1% and 11.5%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment. KW - brain metastases KW - cerebral metastases KW - BM KW - colorectal cancer KW - CRC KW - systematic review KW - meta-analysis Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-228883 SN - 2072-6694 VL - 13 IS - 4 ER - TY - THES A1 - Morche, Susanne T1 - Single-Voxel- versus Multi-Voxel-Protonen-MR-Spektroskopie bei verschiedenen intrakraniellen Läsionen T1 - Single-voxel- versus multi-voxel-proton -MR-spectroscopy in different intracranial lesions N2 - Diese Arbeit untersucht die Fragestellung ob bei der Untersuchung von gesundem Hirngewebe und pathologischen,intrakraniellen Läsionen mittels Singelvoxel- versus Multivoxel-MR-Protonen-Spektroskopie signifikant unterschiedliche Ergebnisse bestehen. Untersucht wurden Hirntumoren der WHO-Grade 2 bis 4, Metastasen und fokal-entzündliche Läsionen. Zusammenfassend ist die Unterscheidung zwischen normalem und pathologisch verändertem Hirngewebe am besten mit der Singelvoxel-Methode und Bildung der CHO/CRE-Ratio möglich. Zur Differentialdiagnose und weiteren Malignitätseinschätzung eignet sich die Bildung der CHO/NAA-Ratio mit Singelvoxel-Spektroskopie. Weiterhin ist die parallele Anwendung von Singel- und Multivoxel-Spektroskopie empfehlenswert. N2 - This study investigates the question if there is a significant difference in the analysis of healthy cerebral tissue and pathological, intracranial lesions with singlevoxel- versus multivoxel-MR-proton-spectroscopy. We tested cerebral tumors of grade 2 to 4 (WHO), metastases and focal-inflammatory lesions. In conclusion the best differentiation between normal and pathologically changed tissue was made with the singlevoxel-method and the CHO/CRE-ratio. For further differentiation of the pathological lesions and for grading of tumors the CHO/NAA- ratio with singlevoxel-spectroscopy is prefered. The use of both methods, singlevoxel- and multivoxel-spectroscopy, continues to be recommended. KW - Singlevoxel KW - Multivoxel KW - Protonen-MR-Spektroskopie KW - intrakranielle Läsionien KW - intrakranielle Tumoren KW - singlevoxel KW - multivoxel KW - proton-MR-spectroscopy KW - intracranial lesions KW - intracranial tumors Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12635 ER - TY - JOUR A1 - Montelius, Mikael A1 - Ljungberg, Maria A1 - Horn, Michael A1 - Forssell-Aronsson, Eva T1 - Tumour size measurement in a mouse model using high resolution MRI JF - BMC Medical Imaging N2 - Background Animal models are frequently used to assess new treatment methods in cancer research. MRI offers a non-invasive in vivo monitoring of tumour tissue and thus allows longitudinal measurements of treatment effects, without the need for large cohorts of animals. Tumour size is an important biomarker of the disease development, but to our knowledge, MRI based size measurements have not yet been verified for small tumours (10−2–10−1 g). The aim of this study was to assess the accuracy of MRI based tumour size measurements of small tumours on mice. Methods 2D and 3D T2-weighted RARE images of tumour bearing mice were acquired in vivo using a 7 T dedicated animal MR system. For the 3D images the acquired image resolution was varied. The images were exported to a PC workstation where the tumour mass was determined assuming a density of 1 g/cm3, using an in-house developed tool for segmentation and delineation. The resulting data were compared to the weight of the resected tumours after sacrifice of the animal using regression analysis. Results Strong correlations were demonstrated between MRI- and necropsy determined masses. In general, 3D acquisition was not a prerequisite for high accuracy. However, it was slightly more accurate than 2D when small (<0.2 g) tumours were assessed for inter- and intraobserver variation. In 3D images, the voxel sizes could be increased from 1603 μm3 to 2403 μm3 without affecting the results significantly, thus reducing acquisition time substantially. Conclusions 2D MRI was sufficient for accurate tumour size measurement, except for small tumours (<0.2 g) where 3D acquisition was necessary to reduce interobserver variation. Acquisition times between 15 and 50 minutes, depending on tumour size, were sufficient for accurate tumour volume measurement. Hence, it is possible to include further MR investigations of the tumour, such as tissue perfusion, diffusion or metabolic composition in the same MR session. KW - cancer KW - magnetic resonance KW - animal model KW - volume determination Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124049 VL - 12 IS - 12 ER - TY - THES A1 - Moeller, Richard-Tobias T1 - Vergleich von Miktionscystourethrographie und niedrig dosierter, kontrastverstärkter Miktionsurosonographie mittels Harmonic Imaging zur Diagnostik des vesicoureteralen Refluxes bei Kindern T1 - Diagnosis of vesicoureteric reflux with low-dose contrast-enhanced harmonic ultrasound imaging N2 - Zielsetzung: Harmonic Imaging produziert Bilder mit hoher Orts- und Kontrastauflösung. Die Mikrobläschen im verwendeten Kontrastmittel werden deutlich sichtbarer. Ziel dieser Studie war es, das diagnostische Potential der kontrastverstärkten Miktionsurosonographie (MUS) mittels Harmonic Imaging bei reduzierter Kontrastmitteldosis mit der Miktionszystourethrographie (MCU) zu vergleichen. Material und Methodik: 55 Patienten (17 Jungen, 38 Mädchen; Durchschnittsalter 4 Jahre), die zur Refuxuntersuchung kamen, wurden für die Vergleichsstudie rekrutiert. Im Anschluß an einen Standard-Ultraschall des Harntraktes mit Harmonic Imaging (Sonoline Elegra, Siemens) folgte die Blasenkatheterisierung und die intravesikale Gabe des Ultraschallkontrastmittels Levovist® (300 mg/ml). Anstatt der bei MUS mit konventioneller Ultraschallmodalität verwendeten Menge – 10% des Blasenvolumens – wurde jetzt nur 5% Volumen des Kontrastmittels benutzt. Die Sonographie des Harntraktes wurde wiederholt und auch unter Miktion fortgeführt. Es schloss sich ein MCU an. Ergebnisse: Zur Evaluation standen insgesamt 114 Nieren-Ureter-Einheiten (NUE) zur Verfügung. In 29 NUE wurde mit einer oder beiden Methoden ein vesikoureteraler Reflux (VUR) diagnostiziert. In 7 NUE wurde der Reflux nur mit Hilfe der MUS, in 3 NUE nur mittels MCU diagnostiziert. Beim Vergleich der MUS mit der Referenzmethode MCU waren die diagnostischen Ergebnisse folgendermaßen: 86,4% Sensitivität, 92,4% Spezifität, 73,1% positiver Vorhersagewert und 96,6% negativer Vorhersagewert. Der Korrelationskoeffizient zwischen den beiden Methoden betrug 0,741 (p<0,001). Schlußfolgerungen: MUS mit Harmonic Imaging und halbierter Kontrastmitteldosis ist in Bezug auf Ausschluß und Diagnose eines VUR mit der MCU vergleichbar. Die Reduktion der Kontrastmittelmenge schränkt die Aussagefähigkeit der MUS nicht ein, sondern ermöglicht bei gleichen Ergebnissen eine kostengünstigere Untersuchung. N2 - Background: Harmonic US imaging has been shown to be better than conventional US for the detection and visualisation of microbubbles in contrast-enhanced voiding urosonography (VUS). Objective: To determine the diagnostic efficacy of VUS using a reduced dose of the US contrast medium in comparison to voiding cystourethrography (VCUG). Materials and methods: Fifty-five children (17 boys, 38 girls; mean age 4 years) were recruited. All patients underwent VUS by harmonic imaging followed by VCUG. The dose of the US contrast medium (Levovist®) administered intravesically was half of the recommended dose i.e. 5% of the bladder filling volume. Results: A total of 114 kidney-ureter (K-U) units were available for evaluation. Vesicoureteric reflux (VUR) was detected in 29 K-U units by one or both examination modalities. There was a 91.2% concordance rate between VUS and VCUG. VUR in seven and three K-U units were detected only by VUS and VCUG, respectively. Taking VCUG as the reference method, VUS had the following diagnostic results: 86.4% sensitivity, 92.4% specificity, positive and negative predictive values of 73.1 and 96.6%, respectively. Conclusions: Even when the dose of US contrast medium is halved, the diagnostic efficacy of harmonic VUS is comparable to VCUG. Consequently, we recommend an US contrast medium dose of 5% of the bladder filling volume for the diagnosis of VUR using contrast-enhanced harmonic VUS. KW - Kinder KW - Miktionsurosonographie KW - Ultraschallkontrastmittel KW - Harmonic Imaging KW - Miktionszystourethrographie KW - Children KW - voiding urosonography KW - contrast medium KW - Harmonic Imaging KW - voiding cystourethrography Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-16744 ER -