TY - THES A1 - Ünzelmann, Maximilian T1 - Interplay of Inversion Symmetry Breaking and Spin-Orbit Coupling – From the Rashba Effect to Weyl Semimetals T1 - Zusammenspiel aus Inversionssymmetriebruch und Spin-Bahn-Kopplung – Vom Rashba-Effekt zu Weyl-Halbmetallen N2 - Breaking inversion symmetry in crystalline solids enables the formation of spin-polarized electronic states by spin-orbit coupling without the need for magnetism. A variety of interesting physical phenomena related to this effect have been intensively investigated in recent years, including the Rashba effect, topological insulators and Weyl semimetals. In this work, the interplay of inversion symmetry breaking and spin-orbit coupling and, in particular their general influence on the character of electronic states, i.e., on the spin and orbital degrees of freedom, is investigated experimentally. Two different types of suitable model systems are studied: two-dimensional surface states for which the Rashba effect arises from the inherently broken inversion symmetry at the surface, and a Weyl semimetal, for which inversion symmetry is broken in the three-dimensional crystal structure. Angle-resolved photoelectron spectroscopy provides momentum-resolved access to the spin polarization and the orbital composition of electronic states by means of photoelectron spin detection and dichroism with polarized light. The experimental results shown in this work are also complemented and supported by ab-initio density functional theory calculations and simple model considerations. Altogether, it is shown that the breaking of inversion symmetry has a decisive influence on the Bloch wave function, namely, the formation of an orbital angular momentum. This mechanism is, in turn, of fundamental importance both for the physics of the surface Rashba effect and the topology of the Weyl semimetal TaAs. N2 - Wird die Inversionssymmetrie kristalliner Festkörper gebrochen, ermöglicht dies die Ausbildung von spinpolarisierten elektronischen Zuständen durch Spin-Bahn-Kopplung ohne die Notwendigkeit von Magnetismus. In den vergangenen Jahren wurde eine Vielzahl interessanter physikalischer Phänomene diskutiert, die mit diesem Effekt zusammenhängen, darunter der Rashba-Effekt, topologische Isolatoren sowie Weyl-Halbmetalle. In dieser Arbeit wird das Zusammenspiel von Inversionssymetriebruch und Spin-Bahn-Kopplung sowie insbesondere deren Einfluss auf die Eigenschaften der elektronischen Zustände, also auf die Spin- und Orbital-Freiheitsgrade, experimentell untersucht. Zwei verschiedene Arten geeigneter Modellsysteme werden dazu betrachtet: zweidimensionale Oberflächenzustände, in denen der Rashba-Effekt aufgrund der an der Oberfläche inhärent gebrochenen Inverisonssymetrie auftritt, und ein Weyl-Halbmetall, dessen dreidimensionale Kristallstruktur kein Inversionszentrum besitzt. Winkelaufgelöste Photoelektronenspektroskopie bietet einen impulsaufgelösten Zugang zur Spinpolarisation sowie zur orbitalen Zusammensetzung der elektronischen Zustände mittels Photoelektronenspindetektion und Dichroismus mit polarisiertem Licht. Die in dieser Arbeit gezeigten experimentellen Ergebnisse werden außerdem durch ab-initio Dichtefunktionaltheorierechnungen sowie einfachen Modellbetrachtungen ergänzt und untermauert. Insgesamt zeigt sich, dass das Brechen von Inversionssymmetrie einen entscheidenden Einfluss auf die Bloch-Wellenfunktion hat, nämlich die Ausbildung eines orbitalen Bahndrehimpulses. Dieser Mechanismus ist wiederum von grundlegender Bedeutung sowohl für die Physik des Oberflächen- Rashba-Effekts als auch für die Topologie desWeyl-Halbmetalls TaAs. KW - Rashba-Effekt KW - Inversion Symmetry Breaking KW - Topologie KW - ARPES KW - Spin-Orbit Coupling KW - Orbital Angular Momentum Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-283104 ER - TY - THES A1 - Zusan, Andreas T1 - The Effect of Morphology on the Photocurrent Generation in Organic Solar Cells T1 - Der Einfluss der Morphologie auf die Generierung von Photostrom in organischen Solarzellen N2 - Organic solar cells have great potential to become a low-cost and clean alternative to conventional photovoltaic technologies based on the inorganic bulk material silicon. As a highly promising concept in the field of organic photovoltaics, bulk heterojunction (BHJ) solar cells consist of a mixture of an electron donating and an electron withdrawing component. Their degree of intermixing crucially affects the generation of photocurrent. In this work, the effect of an altered blend morphology on polaron pair dissociation, charge carrier transport, and nongeminate recombination is analyzed by the charge extraction techniques time delayed collection field (TDCF) and open circuit corrected transient charge extraction (OTRACE). Different comparative studies cover a broad range of material systems, including polymer and small-molecule donors in combination with different fullerene acceptors. The field dependence of polaron pair dissociation is analyzed in blends based on the polymer pBTTT-C16, allowing a systematic tuning of the blend morphology by varying the acceptor type and fraction. The effect of both excess photon energy and intercalated phases are minor compared to the influence of excess fullerene, which reduces the field dependence of photogeneration. The study demonstrates that the presence of neat fullerene domains is the major driving force for efficient polaron pair dissociation that is linked to the delocalization of charge carriers. Furthermore, the influence of the processing additive diiodooctane (DIO) is analyzed using the photovoltaic blends PBDTTT-C:PC71BM and PTB7:PC71BM. The study reveals amulti-tiered alteration of the blend morphology of PBDTTT-C based blends upon a systematic increase of the amount of DIO. Domains on the hundred nanometers length scale in the DIO-free blend are identified as neat fullerene agglomerates embedded in an intermixed matrix. With the addition of the additive, 0.6% and 1% DIO already substantially reduces the size of these domains until reaching the optimum 3% DIO mixture, where a 7.1% power conversion efficiency is obtained. It is brought into connection with the formation of interpenetrating polymer and fullerene phases. Similar to PBDTTT-C, the morphology of DIO-free PTB7:PC71BM blends is characterized by large fullerene domains being decreased in size upon the addition of 3% DIO. OTRACE measurements reveal a reduced Langevin-type, super-second order recombination in both blends. It is demonstrated that the deviation from bimolecular recombination kinetics cannot be fully attributed to the carrier density dependence of the mobility but is rather related to trapping in segregated PC71BM domains. Finally, with regard to small-molecule donors, a higher yield of photogeneration and balanced transport properties are identified as the dominant factors enhancing the efficiency of vacuum deposited MD376:C60 relative to its solution processed counterpart MD376:PC61BM. The finding is explained by a higher degree of dimerization of the merocyanine dye MD376 and a stronger donor-acceptor interaction at the interface in the case of the vacuum deposited blend. N2 - Organische Solarzellen sind dank der Möglichkeit einer preisgünstigen und umweltfreundlichen Herstellung eine erfolgversprechende Alternative zu konventionellen Photovoltaiktechnologien, bei denen heutzutage hauptsächlich Silizium zum Einsatz kommt. Ein aussichtsreiches Konzept ist dabei die Heterogemisch (bulk heterojunction , BHJ)-Solarzelle. Deren aktive Schicht besteht aus einer Elektron-gebenden und einer Elektron-entziehenden Komponente, wobei die Generierung von Photostrom entscheidend von der Durchmischung beider Materialien abhängt. Dieser Einfluss der Morphologie auf die Trennung von Polaronpaaren, den Transport von freien Ladungsträgern und deren nichtgeminale Rekombination wird durch die Verwendung der Ladungsextraktionsmethoden time delayed collection field (TDCF) sowie open circuit corrected transient charge extraction (OTRACE) in dieser Arbeit im Detail untersucht. Die vorgestellten Studien umfassen mit Polymeren und kleinen Molekülen als Donatoren sowie verschiedenen Fulleren-Akzeptoren unterschiedlichste Materialsysteme. Der erste Teil der Arbeit befasst sich mit der feldabhängigen Trennung von Polaronpaaren in Solarzellen, die unter Verwendung des Polymers pBTTT-C16 hergestellt werden. Das Materialsystem erlaubt eine systematische Anpassung der Morphologie durch Art und Anteil des Akzeptors. Die Untersuchungen zeigen, dass sowohl Überschussenergie als auch interkalierte Phasen lediglich eine geringe Auswirkung auf die Photogenerierung haben, diese jedoch stark von der Fullerenmenge im Gemisch beeinflusst wird. Das Ergebnis verdeutlicht, dass reine Fullerendomänen die treibende Kraft für eine effiziente Trennung von Polaronpaaren sind, was mit der Delokalisierung von Ladungsträgern verknüpft wird. Im zweiten Teil wird der Einfluss des Additivs Diiodooktan (DIO) auf das Materialsystem PBDTTT-C:PC71BM untersucht. Die Studie zeigt eine mehrstufige Änderung der Morphologie bei einer schrittweisen Erhöhung der verwendeten DIO Menge. Wird das Heterogemisch PBDTTT-C:PC71BM ohne DIO hergestellt, ist dessen Nanostruktur durch große Agglomerate geprägt, die als reine Fullerendomänen identifiziert werden. Bereits die Verwendung von 0.6% und 1% DIO führt zu einer deutlichen Verkleinerung dieser Domänen, wobei erst die maximale Effizienz der mit 3% DIO hergestellten Solarzelle mit der Ausbildung von vernetzten Polymer- und Fullerenphasen in Verbindung gebracht wird. Vergleichbar zu PBDTTT-C weist auch PTB7:PC71BM große Fullerendomänen und deren bessere Dispersion durch die Verwendung von 3% DIO auf. In beiden Fällen zeigt OTRACE eine reduzierte Langevin-artige Rekombination sowie die Abweichung von einem bimolekularen Verhalten. Da diese erhöhte Rekombinationsordnung nicht mit der Ladungsträgerdichtenabhängigkeit der Mobilität erklärt werden kann, wird sie dem Einfangen von Ladungsträgern in Fullerendomänen zugeordnet. Im letzten Teil wird gezeigt, dass eine ergiebigere Photogenerierung sowie ausgeglichene Transporteigenschaften eine erhöhte Bauteileffizienz von aufgedampften MD376:C60 Solarzellen im Vergleich zum flüssigprozessierten Pendant MD376:PC61BM bedingen. Die Beobachtung wird mit einer verbesserten Dimerisation des Merocyanins MD376 und einer stärkeren Donator-Akzeptor-Wechselwirkung an der Grenzfläche erklärt. KW - Organische Solarzelle KW - Photostrom KW - Ladungsträgergenerierung KW - geminale Rekombination KW - nichtgeminale Rekombination KW - Elektronentransport KW - Photovoltaik KW - Rekombination Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-117852 ER - TY - THES A1 - Zipf, Matthias T1 - Berührungslose Temperaturmessung an Gasen und keramisch beschichteten Oberflächen bei hohen Temperaturen T1 - Non-contact temperature measurement of gases and ceramic coated surfaces N2 - Stationäre Gasturbinen können von großer Bedeutung für die Verlangsamung des Klima-wandels und bei der Bewältigung der Energiewende sein. Für die Weiterentwicklung von Gasturbinen zu höheren Betriebstemperaturen und damit einhergehend zu höheren Wirkungs-graden werden berührungslose Messverfahren zur Ermittlung der Oberflächentemperatur von Turbinenschaufeln und der Gastemperatur der heißen Verbrennungsgase während des Be-triebs benötigt. Im Rahmen dieser Arbeit werden daher Methoden der berührungslosen Tem-peraturmessung unter Verwendung von Infrarotstrahlung untersucht. Die berührungslose Messung der Oberflächentemperatur moderner Turbinenschaufeln muss aufgrund derer infrarot-optischer Oberflächeneigenschaften im Wellenlängenbereich des mitt-leren Infrarots durchgeführt werden, in welchem die Turbinenbrenngase starke Absorptions-banden aufweisen. Zur Entwicklung eines adäquaten Strahlungsthermometers für diesen Zweck wurden im Rahmen dieser Arbeit daher durch Ermittlung von Transmissionsspektren von Kohlenstoffdioxid und Wasserdampf bei hohen Temperaturen und Drücken in einer ei-gens hierfür konstruierten Heißgas-Messzelle zunächst Wellenlängenbereiche identifiziert, in welchen die geplanten Messungen möglich sind. Anschließend wurde der Prototyp eines ent-sprechend konfigurierten Strahlungsthermometers im Zuge des Testlaufes einer vollskaligen Gasturbine erfolgreich erprobt. Weiterhin wurden im Rahmen dieser Arbeit zwei mögliche Verfahren zur berührungslosen Gastemperaturmessung untersucht. Das erste untersuchte Verfahren setzt ebenfalls auf Strah-lungsthermometrie. Dieses Verfahren sieht vor, aufgrund der Temperaturabhängigkeit des spektralen Transmissionsgrades in den Randbereichen von gesättigten Absorptionsbanden von Gasen aus der in diesen Bereichen transmittierten spektralen Strahldichte auf die Gastempera-tur zu schließen. Im Rahmen dieser Arbeit wurden Voruntersuchungen für dieses Tempera-turmessverfahren durchgeführt. So konnten auf der Grundlage von experimentell ermittelten Transmissionsspektren von Kohlenstoffdioxid bei Drücken zwischen 5 kPa und 600 kPa und Gastemperaturen zwischen Raumtemperatur und 1073 K für das geplante Verfahren nutzbare Wellenlängenintervalle insbesondere im Bereich der Kohlenstoffdioxid-Bande bei 4,26 µm identifiziert werden. Das zweite im Rahmen dieser Arbeit untersuchte Verfahren zur berührungslosen Gastem-peraturmessung basiert auf der Temperaturabhängigkeit der Wellenlängenposition der Trans-missionsminima der Absorptionsbanden von infrarot-aktiven Gasen. Im Hinblick darauf wur-de dieses Phänomen anhand von experimentell bestimmten hochaufgelösten Transmissions-spektren von Kohlenstoffdioxid überprüft. Weiterhin wurden mögliche Wellenlängenbereiche identifiziert und hinsichtlich ihrer Eignung für das geplante Verfahren charakterisiert. Als am vielversprechendsten erwiesen sich hierbei Teilbanden in den Bereichen um 2,7 µm und um 9,2 µm. Unter Beimischung von Stickstoff mit Partialdrücken von bis zu 390 kPa erwies sich zudem auch die Bande bei 4,26 µm als geeignet. Die im Rahmen dieser Arbeit experimentell ermittelten Transmissionsspektren konnten dar-über hinaus schließlich durch Vergleich mit entsprechenden HITRAN-Simulationen verifiziert werden. N2 - Stationary gas turbines can be of significant importance for slowing down climate change and for the handling of the energy transition. The goal of the further development of gas tur-bines is to increase the operating temperatures and in consequence the efficiency factor. For this purpose, non-contact measurement methods are required to determine the surface temper-ature of turbine blades and the gas temperature of the hot combustion gases during operation. Therefore, methods of non-contact temperature measurement using infrared radiation are in-vestigated in this work. Due to the infrared-optical surface properties of modern turbine blades, non-contact tem-perature measurement has to be carried out in the mid-infrared wavelength range, where com-bustion gases of gas turbines have strong absorption bands. In order to develop an adequate radiation thermometer for this purpose, as a first step in this work, wavelength ranges were identified by determining the transmission spectra of carbon dioxide and water vapor at high temperatures and pressures in which the planned measurements are possible. Therefore, a spe-cial high-temperature high-pressure gas cell was developed. Then the prototype of a radiation thermometer, which was configured for measurements in the wavelength region identified before, was successfully tested in a full-scale gas turbine. Furthermore, two possible methods for non-contact gas temperature measurement were in-vestigated in the scope of this work. The first method examined also relies on radiation ther-mometry. Within this method, it is planned to obtain the gas temperature from the measure-ment of the spectral radiance that is transmitted in the wavelength region of the edge of a sat-urated absorption band of the gas, due to the temperature dependence of the spectral transmit-tance in this wavelength region. In this work, preliminary investigations for this temperature measurement method were carried out. Based on experimentally determined transmission spectra of carbon dioxide at pressures between 5 kPa and 600 kPa and at temperatures be-tween room temperature and 1073 K, wavelength intervals were identified that are suitable for the planned measurement method. Especially in the region of the carbon dioxide band at 4.26 µm, appropriate intervals could be found. The second method for non-contact gas temperature measurement investigated in this the-sis is based on the temperature dependence of the wavelength position of the transmission minima of the absorption bands of infrared-active gases. Therefore, this phenomenon was in-vestigated using experimentally determined high-resolution transmission spectra of carbon dioxide. Furthermore, suitable wavelength ranges with appropriate absorption bands were identified and characterized. The most promising sub-bands were found in the wavelength regions around 2.7 µm and 9.2 µm. Under addition of nitrogen with partial pressures up to 390 kPa, the carbon dioxide band at 4.26 µm also turned out to be suitable for the planned temperature measurement method. Finally, the experimentally gathered transmission spectra, which were obtained in the scope of this work, could be verified by a comparison with corresponding HITRAN-simulations. KW - Pyrometrie KW - Gas KW - thermal barrier coating Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-240248 ER - TY - THES A1 - Zinner, Martin Gerhard T1 - Adsorbat-induzierte Oberflächensysteme und ultra-dünne intermetallische Legierungsfilme im Fokus der niederenergetischen Elektronenbeugung und spektroskopischer Analysemethoden T1 - Adsorbate-unduced surface systems and ultra-thin intermetallic alloy films in the focus of low-energy electron diffraction and spectroscopic analysis methods N2 - Im Rahmen der vorliegenden Dissertation werden mit unterschiedlichen Analysemethoden die Korrelationen zwischen den strukturellen, elektronischen und magnetischen Eigenschaften von Selten Erd-basierten intermetallischen Oberflächenlegierungen anhand der beiden Probensysteme LaPt$_5$/Pt(111) und CePt$_5$/Pt(111) untersucht. Darüber hinaus werden die strukturellen Eigenschaften von Adsorbat-induzierten Oberflächenrekonstruktionen im sub-ML Bereich in reduzierten Dimensionen auf der Halbleiteroberfläche Si(111) anhand der beiden Materialsysteme Si(111)-(5$\times$2)-Au und Si(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn mit der Methode LEED-IV analysiert. Das erste experimentelle Kapitel dieser Arbeit behandelt die intermetallische Oberflächenlegierung LaPt$_5$/Pt(111), die sich ausbildet wenn La-Atome auf einem sauberen Pt(111)-Substrat abgeschieden werden und anschließend thermische Energie hinzugefügt wird. Die Dicke der gebildeten Legierung lässt sich über die zuvor angebotene Menge an La-Atomen variieren und resultiert aufgrund der Gitterfehlanpassung von Pt(111) und den obenauf liegenden LaPt$_5$-Filmen in sechs unterschiedliche Beugungsmuster im LEED, deren Überstrukturvektoren durch zwei unterschiedliche Rotationsausrichtungen in Bezug auf das Gitter des Substrats und unterschiedlichen lateralen Gitterkonstanten der Filme gekennzeichnet sind. Die atomare Struktur kann auf eine gemeinsame Kristallstruktur zurückgeführt werden, deren Stöchiometrie aus dickenabhängigen AES-Messungen zu LaPt$_5$ mit einer Pt-reichen Oberflächenabschlusslage bestimmt werden konnte. Die Ergebnisse einer durchgeführten LEED-IV Studie bestätigen das Wachstum der Filme in der CaCu$_5$-Struktur, wobei die Oberflächenterminierungslage im Vergleich zum Volumengitter ein zusätzliches Pt-Atom pro Einheitszelle aufweist, das zusätzlich um einen Wert von \unit{0.26}{\angstrom} aus der Oberfläche hervorsteht. Die La-Atome, die direkt unterhalb der Terminierungslage liegen, erfahren eine Verschiebung in entgegengesetzter Richtung, so dass im Vergleich zum Volumen der Filme eine lokal veränderte Symmetrie im oberflächennahen Bereich vorherrscht und sich auf die elektronischen Eigenschaften der LaPt$_5$-Filme auswirkt. Darüber hinaus wurden die Schwingungseigenschaften der LaPt$_5$-Filme mittels der polarisierten in situ Raman-Spektroskopie bestimmt, bei der die auftretenden Schwingungspeaks durch die Kenntnis der atomaren Struktur und mit Überlegungen aus der Gruppentheorie unterschiedlichen Tiefenbereichen der LaPt$_5$-Filme (Volumen und Oberfläche) zugewiesen werden konnten. Im zweiten experimentellen Kapitel liegt der Fokus auf der atomaren Struktur sowie auf den elektronischen und magnetischen Eigenschaften des Kondo- und Schwerfermionensystems CePt$_5$/Pt(111). In Abhängigkeit von der vor dem Legierungsprozess angebotenen Menge an Ce-Atomen auf dem Pt(111)-Substrat konnten insgesamt sieben verschiedene LEED-Phasen der CePt$_5$-Filme identifiziert werden, deren jeweilige Oberflächenrekonstruktionen durch eine unterschiedliche Rotationsausrichtung in Bezug auf das Pt(111)-Substrat gekennzeichnet sind. Zusätzlich ist die laterale Gitterkonstante einem Prozess aus Verspannung und Dehnung aufgrund der Gitterfehlanpassung von Film und Substrat ausgesetzt. Eine durchgeführte LEED-IV Analyse bestätigt das Wachstum der Filme in der CaCu$_5$-Struktur mit einer Pt-reichen Oberflächenabschlusslage, deren Pt$_3$-Kagom\'{e}-Lage im Vergleich zum Volumengitter mit einem zusätzlichen Pt-Atom pro Einheitszelle gefüllt ist. Die strukturellen Ergebnisse stimmen mit erzielten Resultaten aus früheren Arbeiten überein und verdeutlichen zudem die isostrukturellen Eigenschaften zur intermetallischen Oberflächenlegierung LaPt$_5$/Pt(111). Dies ermöglicht durch geeignete Vergleichsexperimente an LaPt$_5$/Pt(111) die induzierten Phänomene der $4f$-Elektronen bezüglich des Kondo- und Schwerfermionenverhaltens bei CePt$_5$/Pt(111) zu bestimmen, da La-Atome in ihrem atomaren Aufbau keine $4f$-Elektronen beherbergen. Mit der polarisierten in situ Raman-Spektroskopie aufgenommene Spektren anhand von unterschiedlich dicken CePt$_5$-Filmen beinhalten sowohl charakteristische Schwingungspeaks als auch elektronische Übergänge. Das spektroskopische Verhalten der Schwingungspeaks zeigt dabei nicht nur Gemeinsamkeiten zu LaPt$_5$/Pt(111) bei der Zuweisung der Schwingungsmoden zu den jeweiligen Tiefenbereichen in den CePt$_5$-Filmen, sondern es treten auch Unterschiede auf, da eine CePt$_5$-Schwingungsmode einem anormalen Temperaturverhalten unterliegt, das auf die Wechselwirkung mit den $4f$-Elektronen zurückzuführen ist. Weitere spezifische Raman-Signaturen, die elektronischen Übergängen in Form von Kristallfeldniveauaufspaltungen der $4f$-Elektronen von Ce zugewiesen werden konnten, resultieren ebenfalls aus unterschiedlichen Regionen der CePt$_5$-Filme (Oberfläche, inneres Volumen, Interface). Die magnetischen Eigenschaften der CePt$_5$-Filme wurden mit XAS und XMCD an den Ce M$_{4,5}$-Kanten in Abhängigkeit von der Temperatur, dem Einfallswinkel, der Filmdicke und der Stärke des Magnetfelds analysiert. Die markanten Übergänge zwischen unterschiedlichen Curie-Weiss-Regimen in der inversen Suszeptibilität erlauben Rückschlüsse über das Kristallfeldaufspaltungsschema, die Kondo- und die RKKY-Wechselwirkung und korrelieren mit der Ce-Valenz. Zudem konnte bei tiefen Temperaturen ein Übergang in den kohärenten Schwerfermionen-Zustand für alle untersuchten CePt$_5$-Filmdicken in dieser Arbeit nachgewiesen werden. Durch die Vorhersage eines metamagnetischen Lifshitz-Übergangs für diese Filme, der sich in der Magnetfeldabhängigkeit des magnetischen Moments äußert, konnte durch die Aufnahme von Magnetisierungskurven bei tiefen Temperaturen und hohen Magnetfeldern auf zwei weitere charakteristische Energieskalen der renormalisierten Bandstruktur zugegriffen werden. Das dritte experimentelle Kapitel widmet sich der mit LEED und LEED-IV durchgeführten Aufklärung der atomaren Struktur eines quasi-eindimensionalen Elektronensystems, bei dem sich die gebildeten Au-Nanodrähte auf der Si(111)-Oberfläche durch eine Si(111)-(5$\times$2)-Au Rekonstruktion beschreiben lassen. Die aufgenommenen LEED-Bilder mit ihren markanten Beugungsreflexen und sogenannten Streifen deuten auf drei gleichwertige Rotationsdomänen, die jeweils um einen Winkel von \unit{120}{\degree} gegeneinander gedreht sind, auf der Oberfläche hin. Zudem konnte aus einer Simulation der Beugungsbilder das Auftreten von Streifen durch drei zusätzliche Spiegeldomänen, die eine Phasenverschiebung von einem halben Überstrukturvektor einführen und bei einer sorgfältigen LEED-IV Analyse ebenfalls berücksichtigt werden sollten, erklärt werden. Aus den in der Literatur nach einer zweiten Rekalibrierung der nötigen Menge an Au-Atomen zur Ausbildung der Si(111)-(5$\times$2)-Au Rekonstruktion in den letzten Jahren heftig diskutierten Strukturmodellen gibt das von Kwon und Kang aufgestellte Geometriemodell (KK-Modell) die beobachteten energieabhängigen Intensitätsmodulationen in den experimentellen Daten beim Vergleich mit theoretisch berechneten IV-Kurven am besten wieder. Für dieses Modell nimmt der R-Faktor nach Pendry bei den unabhängig voneinander betrachteten drei Energieserien unter verschiedenen Einfallswinkeln der Elektronen auf die Probenoberfläche stets den kleinsten Wert an. Unter der expliziten Berücksichtigung von Si-Adatomen, die sich zusätzlich auf der Oberfläche befinden und in einer (5$\times$4)-Einheitszelle beschrieben werden können, bleibt das KK-Modell das zu präferierende Strukturmodell zur Beschreibung der ausgebildeten Au-Ketten und der Si-Honigwabenstruktur bei der Si(111)-(5$\times$2)-Au Oberflächenrekonstruktion. Im letzten experimentellen Kapitel wird ein zweidimensionales Elektronensystem -- die $\alpha$-Si(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn Oberflächenrekonstruktion, die sich bei 1/3 ML an Sn-Adsorbaten auf dem Si(111)-Substrat ausbildet -- im Hinblick auf die atomare Struktur bei Raumtemperatur mit LEED und LEED-IV untersucht. Aus den insgesamt sechs in die Analyse aufgenommenen Strukturmodellen, bei denen die Sn-Atome innerhalb der rekonstruierten ($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Einheitszelle unterschiedliche Adsorptionsplätze auf einer ideal terminierten Si(111)-Oberfläche einnehmen, konnte ein Legierungsverhalten, wie es bei der $\gamma$-Si(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn Phase auftritt, ausgeschlossen werden. Die Sn-Atome ordnen sich ausschließlich auf der Oberfläche neu an und führen zu einer Relaxation des darunterliegenden Substrats, deren atomare Verschiebungen sich bis in die sechste Si-Lage nachverfolgen lassen. Im Vergleich zu früheren Strukturaufklärungen an diesem Materialsystem bestätigt diese Analyse, dass sich die abgeschiedenen Sn-Atome auf T$_4$-Adsorptionsplätzen energetisch günstig anlagern, wobei die bei drei unterschiedlichen Einfallswinkeln aufgenommenen experimentellen Daten an unterschiedlichen Probenpositionen auf ein vorhandenes bzw. fehlendes Si-Atom auf einem S$_5$-Gitterplatz im darunterliegenden Si(111)-Substrat hindeuten. Außerdem konnte das theoretisch vorhergesagte dynamische Fluktuations-Modell aufgrund der sehr stark erhöhten thermischen Auslenkungen der Sn-Atome aus ihrer Gleichgewichtslage in den Modellrechnungen zur dynamischen Streutheorie nachgewiesen werden. Dies könnte neben den unregelmäßig angeordneten Si-Fehlstellen eine Ursache für das Ausbleiben des strukturell reversiblen Phasenübergangs von einer ($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Phase zu einer (3$\times$3)-Phase bei tiefen Temperaturen, wie er beispielsweise beim elektronisch vergleichbaren Adsorbatsystem Ge(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn auftritt, sein. N2 - In the scope of the present PhD thesis the correlations between the structural, electronic, and magnetic properties of rare earth-based intermetallic surface compounds are examined by means of different analysis methods on the basis of the two sample systems LaPt$_5$/Pt(111) and CePt$_5$/Pt(111). In addition, the structural properties of adsorbate-induced surface reconstructions in the sub-ML range in reduced dimensions on the semiconductor surface Si(111) are analyzed on the basis of the two material systems Si(111)-(5$\times$2)-Au and Si(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn with LEED-IV. The first experimental chapter of this thesis deals with the intermetallic surface compound LaPt$_5$/Pt(111). LaPt$_5$/Pt(111) forms when La atoms are deposited onto a clean Pt(111) substrate and subsequently thermal energy is applied. The thickness of the intermetallic film can be varied over the amount of La atoms offered before the alloying process and results in a total of six different diffraction patterns in LEED due to the lattice mismatch of Pt(111) and the LaPt$_5$ films on top. The superstructure vectors of the films formed are characterized by two different rotational orientations with respect to the lattice of the substrate and different lateral lattice constants of the films. The atomic structure can be traced back to a common crystal structure whose stoichiometry could be determined out of thickness dependent AES measurements to LaPt$_5$ with a Pt-rich surface termination layer. The results of a LEED-IV study confirm the growth of the films in the CaCu$_5$ structure, where the surface termination layer contains an additional Pt atom per unit cell compared to the bulk lattice. Additionally, this Pt atom protrudes from the surface by a value of \unit{0.26}{\angstrom}. The La atoms directly underneath the termination layer are shifted in opposite direction and therefore a locally changed symmetry prevails in the near surface region compared to the volume of the films and furthermore the electronic properties of the LaPt$_5$ films are affected. In addition, the vibrational properties of the LaPt$_5$ films were determined by means of polarized in situ Raman spectroscopy, in which the occurring vibrational peaks could be assigned to different depth regions of the LaPt$_5$ films (volume and surface) by knowledge of the detailed atomic structure and further considerations from group theory. In the second experimental chapter, the focus is put on the atomic structure and the electronic and magnetic properties of the Kondo- and heavy-fermion system CePt$_5$/Pt(111). Depending on the amount of Ce atoms offered before the alloying process on the Pt(111) substrate, a total of seven different LEED phases of the CePt$_5$ films could be identified, whose respective surface reconstructions are characterized by two different rotational orientations with respect to the Pt(111) substrate. Additionally the lateral lattice constant of the films are exposed to a process of stress and strain due to the lattice mismatch between film and substrate. A LEED-IV analysis confirms the growth of the films in the CaCu$_5$ structure with a Pt-rich surface termination layer whose Pt$_3$-Kagom\'{e} layer is filled with one additional Pt atom per unit cell compared to the bulk lattice. The structural results agree with results obtained in earlier studies and furthermore also illustrate the isostructural properties towards the intermetallic surface compound LaPt$_5$/Pt(111). The structural agreement between the two intermetallic surface compounds allows the determination of the $4f$ electrons induced phenomena with respect to the Kondo- and heavy-fermion behavior in CePt$_5$/Pt(111) by suitable comparative experiments on LaPt$_5$/Pt(111), since La atoms in their atomic structure do not contain $4f$ electrons. Spectra recorded with polarized in situ Raman spectroscopy of CePt$_5$ films with different film thicknesses contain both characteristic vibrational peaks and signatures of electronic transitions. The spectroscopic behavior of the vibrational peaks show similarities to LaPt$_5$/Pt(111) in the assignment of the vibrational modes to the respective depth regions in the CePt$_5$ films, but also differences occur, since one vibrational mode of CePt$_5$ is subject to an anomalous temperature behavior, which is attributed to the interaction with the $4f$ electrons. Further specific Raman signatures, which could be assigned to electronic transitions in form of level splitting of the $4f$ electron of the Ce atoms due to the crystal field of the Pt atoms, also originate from different depth regions of the CePt$_5$ films (surface, inner volume, interface). The magnetic properties of the CePt$_5$ films were analyzed with XAS and XMCD at the Ce M$_{4,5}$ edges as a function of temperature, angle of incidence, film thickness, and magnetic field strength. The prominent transitions in the inverse susceptibility between different Curie-Weiss regimes allow conclusions to be drawn about the crystal field splitting scheme, the Kondo- and RKKY-interactions and show a significant correlation with the Ce-valence. Furthermore, for all investigated CePt$_5$ film thicknesses in this thesis at low temperatures a transition to the coherent heavy-fermion state could be detected. By predicting a metamagnetic Lifshitz transition for these films, which is expressed in the magnetic field dependence of the magnetic moment, two further characteristic energy scales of the renormalized band structure could be accessed by recording magnetization curves at low temperatures and high magnetic fields. The third experimental chapter is devoted to the elucidation of the atomic structure of a quasi one-dimensional electron system with LEED and LEED-IV, in which the Au nanowires formed on the Si(111) surface can be described by a Si(111)-(5$\times$2)-Au reconstruction. The recorded LEED images include both a striking diffraction pattern and so-called diffraction streaks indicative for the existence of three equivalent rotational domains on the reconstructed surface, rotated by an angle of \unit{120}{\degree} against each other. In addition, the occurrence of diffraction streaks in the observed diffraction pattern could be explained through a theoretical simulation by the existence of three additional mirror domains on the surface, which introduce a phase shift of half a superstructure vector and should also be considered in a thorough LEED-IV analysis. From the structural models discussed vigorously in recent years in the literature after the introduction of a second recalibration of the necessary amount of Au atoms required for the formation of the Si(111)-(5$\times$2)-Au reconstruction, the geometry model established by Kwon and Kang (KK model) reflects best the observed energy-dependent intensity modulations in the experimental data when compared with calculated IV curves. For this model, the R-factor by Pendry always adopts its smallest value for the three energy series considered independently of each other at different angles of incidence of the electrons on the sample surface. Furthermore, even under explicit consideration of Si adatoms, which are additionally located on top of the reconstructed surface and can be described in a (5$\times$4) unit cell, the KK model remains the preferred structural model for the description of the Au chains formed and the Si honeycomb structure of the Si(111)-(5$\times$2)-Au surface reconstruction. In the final experimental chapter, a two-dimensional electron system -- the $\alpha$-Si(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn surface reconstruction, which is formed at a total coverage of 1/3 ML of Sn adsorbates on the Si(111) substrate -- is investigated with regard to the atomic structure at room temperature with LEED and LEED-IV. From a total of six structural models included in the analysis, in which the Sn atoms on an ideally terminated Si(111) surface occupy different adsorption sites within the reconstructed ($\sqrt{3}\times\sqrt{3}$)R30${\degree}$ unit cell, it was possible to exclude alloying such as observed for the $\gamma$- Si(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn phase. The Sn atoms rearrange exclusively on the surface and lead to a relaxation of the underlying substrate, whose atomic displacements can be traced back to the sixth Si layer. In comparison to earlier structural investigations conducted on this material system, the presented analysis confirms that the deposited Sn atoms are energetically favorably deposited at T$_4$ adsorption sites. Furthermore, the experimental data recorded at three different angles of incidence from different positions on the sample show indications of an existing and/or missing Si atom on a S$_5$ lattice site in the underlying Si(111) substrate. In addition, the theoretical prediction of the dynamic fluctuation model for this surface reconstruction could be proven in the model calculations of the dynamic scattering theory due to the very strongly increased thermal displacements of the Sn atoms from their equilibrium position. Besides from the irregularly arranged Si defects, this could be a hint for the absence of the reversible structural phase transition at low temperatures from a ($\sqrt{3}\times\sqrt{3}$)R30${\degree}$ phase to a (3$\times$3) phase, as it occurs in the electronically comparable adsorbate system Ge(111)-($\sqrt{3}\times\sqrt{3}$)R30${\degree}$-Sn. KW - Schwere-Fermionen-System KW - LEED KW - Magnetischer Röntgenzirkulardichroismus KW - Raman-Spektroskopie KW - Kristallfeld KW - dünne intermetallische Filme KW - geordnete Metalladsorbate auf Halbleiteroberflächen Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-192749 ER - TY - THES A1 - Zimmermann, Jörg T1 - Optische Wellenleiter und Filter in photonischen Kristallen auf Indiumphosphid-Basis T1 - Optical waveguides and filters in photonic crystals based on indium phosphide N2 - Im Rahmen dieser Arbeit wurden optische Wellenleiter und Filter in zweidimensionalen photonischen Kristallen auf Indiumphosphid-Basis hergestellt, numerisch modelliert sowie experimentell im für die optische Nachrichtentechnik wichtigen Wellenlängenbereich um 1,55 µm untersucht. Photonische Kristalle weisen eine periodische Variation des Brechungsindex auf. Durch das gezielte Einbringen von Defekten in die periodische Struktur ist eine Manipulation der photonischen Zustandsdichte und somit der Lichtausbreitung möglich. Grundbaustein der durchgeführten Untersuchungen ist der lineare Defektwellenleiter in einem triangulären Gitter aus Luftlöchern in einer Halbleitermatrix, der durch das Auslassen von einer oder mehreren Lochreihen entsteht. Die Wellenführung in vertikaler Richtung wird durch eine Halbleiterheterostruktur mit einer Wellenleiterkernschicht aus InGaAsP oder InGaAlAs und Mantelschichten mit niedrigerem Brechungsindex realisiert. Die Einbettung des zweidimensionalen Lochgitters in die InP-basierte Halbleiterheterostruktur erlaubt die Integration mit aktiven optoelektronischen Bauteilen wie Sende- und Empfangselementen sowie die Verwendung bestehender Halbleiterstrukturierungstechnologien. Die photonischen Kristall-Wellenleiter wurden mit hochauflösender Elektronenstrahllithographie und einem zweistufigen Trockenätzprozess hergestellt. Damit konnten Lochradien von 100 nm und Lochtiefen von 4 µm realisiert werden. Zur experimentellen Untersuchung der hergestellten Strukturen wurden Messplätze für die optische Charakterisierung von Transmission und chromatischer Dispersion von photonischen Kristall-Wellenleitern und -Filtern aufgebaut und die Phasenverschiebungsmethode sowie die Modulationsmethode mit Offset angewendet. Damit konnte erstmals direkt die Gruppenlaufzeitdispersion eines photonischen Kristall-Wellenleiter-Filters gemessen werden. Numerische Untersuchungen wurden mit dem Verfahren der Entwicklung nach ebenen Wellen sowie mit dem FDTD-Verfahren durchgeführt. Die photonischen Kristall-Wellenleiter besitzen mehrere Wellenleitermoden, die teilweise refraktiven (auf Totalreflexion beruhenden) und teilweise diffraktiven (auf Bragg-Reflexion beruhenden) Charakter haben. Je nach Symmetrie treten zwischen den Moden Ministoppbänder auf, die sich im Transmissionsspektrum als Intensitätseinbrüche darstellen. Die spektrale Lage dieser Ministoppbänder hängt von der Wellenleitergeometrie ab. Messungen an Wellenleitern mit verschiedener Länge zeigen eine starke Variation der spektralen Breite der Ministoppbänder. Diese kann mit der Theorie der gekoppelten Moden unter Annahme unterschiedlicher Dämpfungswerte für die gekoppelten Wellenleitermoden erklärt werden. Die entscheidene Wellenleitereigenschaft für praktische Anwendungen ist die Wellenleiterdämpfung. Diese wurde mit den Verfahren der Fabry-Pérot-Resonanzen sowie der Längenvariation experimentell bestimmt. Durch Wahl eines geeigneten Schichtaufbaus und Optimierung der Herstellungsprozesse konnten die für das untersuchte Materialsystem niedrigsten Dämpfungswerte in photonischen Kristall-Wellenleitern erzielt werden. Für W7-, W5- und W3-Wellenleiter wurden Dämpfungswerte von 0,2 dB/mm, 0,6 dB/mm und 1,5 dB/mm erreicht, die schmaleren W1-Wellenleiter zeigen Verluste von 27 dB/mm. Zwei Typen optischer Wellenleiter-Filter wurden untersucht: Richtkoppler sowie Resonatoren. Photonische Kristall-Wellenleiter-Richtkoppler eignen sich als ultrakompakte Demultiplexer und Kanal-Auslasser. Bei den experimentell realisierten photonischen Kristall-Wellenleiter-Richtkopplern konnte das eingekoppelte Licht je nach Wellenlänge in den einen oder anderen Ausgangswellenleiter gelenkt werden. Bei photonischen Kristall-Wellenleitern mit Resonatoren konnten Güte-Faktoren bis zu 1,5*10^4 bei einem Kanalabstand von 100 GHz realisiert werden. Die Gruppenlaufzeitdispersion in diesen Strukturen variiert zwischen -250 ps/nm und +250 ps/nm, so dass mit einem 420 µm langen photonischen Kristall-Wellenleiter-Filter die Dispersion von 15 km Standardglasfaser bei 1,55 µm Wellenlänge kompensiert werden kann. Mit Hilfe von kleinen Temperaturänderungen kann die Resonanzkurve verschoben werden. Der demonstrierte photonische Kristall-Wellenleiter-Resonator stellt daher einen miniaturisierten durchstimmbaren Dispersionskompensator dar. N2 - Optical waveguides and filters in two-dimensional photonic crystals based on indium phosphide have been fabricated and investigated both numerically and experimentally in the spectral range around the optical communication wavelength of 1.55 µm. Photonic crystals are composed of a periodic arrangement of materials with different refractive indices, e.g. semiconductor material and air, on the scale of the wavelength of light. By inserting defects into the periodic structure, the propagation of light can be manipulated. The linear defect waveguide in a triangular lattice of air holes formed by the omission of one or several rows of holes, serves as the basic building block for the investigated optical filters. Optical confinement in vertical direction is realized by a semiconductor heterostructure with a waveguide core layer out of InGaAsP or InGaAlAs and cladding layers with lower refractive index. Embedding the two-dimensional lattice of air holes in an InP based heterostructure allows for the integration with active optoelectronic devices such as emitters and receivers and the application of existing semiconductor fabrication technologies. The photonic crystal waveguides were fabricated by high-resolution electron beam lithography and a two-step dry etching process, resulting in air holes with radii of 100 nm and depths of 4 µm. For the experimental investigations of the fabricated structures, measurement setups for the optical characterization of transmission and chromatic dispersion of photonic crystal waveguides and waveguide filters were installed. The phase shift method and the modulation method with offset were applied. The group velocity dispersion of a photonic crystal waveguide filter has been measured for the first time. Numerical studies were performed using two-dimensional plane wave expansion and finite difference time domain computations. Several waveguide modes can exist in the photonic crystal waveguides, some of which are of refractive (based on total internal reflection) and some of which are of diffractive nature (based on Bragg reflection). Depending on the mode symmetry, mini-stopbands can occur between the modes, which are observed as intensity dips in the transmission spectra. Transmission measurements of waveguides with various lengths show a strong variation of the spectral width of these mini-stopbands. This behavior can be explained by coupled-mode theory assuming different attenuation coefficients for the coupling waveguide modes. The property most critical for potential use in large-scale photonic integrated circuits is the waveguide loss. The waveguide loss was experimentally determined by the Fabry-Pérot resonance method and by transmission measurements of waveguides with various lengths. By choosing a suitable layer structure and optimizing the fabrication process, it was possible to achieve the lowest waveguide attenuation values for the investigated materials system. For W7, W5, and W3 waveguides, attenuation values of 0.2 dB/mm, 0.6 dB/mm, and 1.5 dB/mm were achieved. The W1 waveguides exhibit waveguide losses of 27 dB/mm. Two types of optical waveguide filters were investigated: directional couplers and resonators. Photonic crystal waveguide directional couplers, formed by two closely spaced linear defect waveguides, can be used as compact demultiplexers or channel interleavers. Wavelength selective operation of the fabricated photonic crystal waveguide directional couplers was demonstrated by directing the injected light signals to either one of the output waveguides, depending on the wavelength. Photonic crystal waveguide resonators were formed by inserting two photonic crystal sections that act as partial reflectors into linear defect waveguides. The fabricated devices with a resonator length of 420 µm show quality factors up to 1.5*10^4 at a channel spacing of 100 GHz. The group velocity dispersion in these structures ranges from -250 ps/nm to +250 ps/nm, sufficing to compensate for the dispersion of 15 km of standard single-mode fiber at wavelengths around 1.55 µm. By controlling the device temperature, the resonance curve and the dispersive properties of the device can be tuned. The demonstrated photonic crystal waveguide resonator therefore can be used as a miniaturized tunable dispersion compensator. KW - Photonischer Kristall KW - Indiumphosphid KW - Lichtwellenleiter KW - Optisches Filter KW - Photonische Kristalle KW - Wellenleiter KW - Resonator KW - Dispersion KW - Indiumphosphid KW - photonic crystals KW - waveguide KW - resonator KW - dispersion KW - indium phosphide Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-21767 ER - TY - THES A1 - Zimmermann, Christian T1 - Halbleiterlaser mit lateralem Rückkopplungsgitter für metrologische Anwendungen T1 - Semiconductor lasers with lateral feedback for metrological applications N2 - In der vorliegenden Arbeit wurde angestrebt, die Eigenschaften komplexgekoppelter DFB-Laser bezüglich ihrer Nutzung für metrologische Untersuchungen zu analysieren und zu verbessern. Hierfür wurden die räumlichen Emissionseigenschaften der lateral komplexgekoppelten DFB-Laser in ausgiebigen Studien diskutiert. Für kommerziell erhältliche Laser wurde daraufhin das Fernfeld sowohl in lateraler als auch vertikaler Richtung berechnet. Die entsprechenden Fernfeldmessungen konnten die Theorie bestätigen und wie erwartet, waren die Divergenzwinkel mit 52° FWHM in der Wachstumsrichtung und 12° FWHM in lateraler Richtung (vgl. Abb. 6.4 und 6.5) sehr unterschiedlich und zeugen von einer großen Differenz in den Fernfeldwinkeln. Mit Überlegungen zu dem optischen bzw. elektrischen Einschlusspotential im Hinblick auf die veränderte Fernfeldsituation wurde zunächst die reine Halbleiterlaserschichtfolge optimiert. Der Divergenzwinkel in Wachstumsrichtung wurde um mehr als 50% auf 25° FWHM gesenkt. Damit konnte die Asymmetrie des Fernfeldes um einen Faktor von mehr als 4 reduziert werden. Strahlgüteuntersuchungen zeigten ein nahezu beugungsbegrenztes Gaußsches Strahlprofil in der langsamen Achse mit einem M2-Wert von 1,13 (Abb. 6.3). Eine weitere Untersuchung betraf die Linienbreitenabhängigkeit solcher Laser von ihrer Ausgangsleistung, der Resonatorlänge, der Facettenvergütung und der Gitterkopplung. Die erste Beobachtung betraf die Verschmälerung der Linienbreite mit ansteigender Ausgangsleistung bis hin zu einer erneuten Verbreiterung (Rebroadening) der Linienbreite (siehe Abb. 7.3). Der Einfluss auf die Linienbreite durch eine Veränderung der Resonatorlänge ließ sich sehr gut mit der Theorie vergleichen und so erbrachte eine Verdopplung der Resonatorlänge eine Verschmälerung der Linienbreite um mehr als einen Faktor 3. Die Verlängerung der Kavität begünstigte den negativen Effekt des sog. Rebroadenings nicht, da bei der verwendeten Technologie der lateral komplexen Kopplung der Index-Beitrag an der Rückkopplung sehr klein ist. Im Falle reiner Indexkopplung wäre dies durch die veränderte κ · L-Lage deutlich zu spüren. Ein weiterer, oben auch angesprochener Vorteil der komplexen Kopplung ist, dass die Facettenreflektivitäten einen wesentlich kleineren Einfluss auf die DFB-Ausbeute und auf deren Eigenschaften haben als bei der reinen Indexkopplung. Dies lässt sich ausnutzen, um die Photonenlebensdauer in der Kavität zu erhöhen ohne negativ die DFB-Ausbeute zu beeinflussen. In dieser Arbeit wurde bei verschiedenen Längen die reine gebrochene Facette mit einer vergüteten verglichen und der Einfluss auf die Linienbreite analysiert. Die Frontfacette wurde durch eine Passivierung bei ca. 30% gehalten und die Rückfacette durch einen doppelten Reflektor auf ca. 85% gesetzt. Daraus resultierte eine Reduktion der Linienbreite um mehr als die Hälfte. Neben diesen Ergebnissen wurde auch der Einfluss der komplexen Kopplung untersucht. Da die durch das Gitter zusätzlich eingebrachten Verluste zu einer Vergrößerung der Linienbreiten beitragen, wird bei einem größeren geometrischen Gitterüberlapp das Frequenzrauschen auch entsprechend steigen. Dies ließ sich auch im Experiment bestätigen. Zudem wurde eine Längenabhängigkeit dieses Effektes festgestellt. Die Reduzierung der Linienbreite bei längeren Bauteilen ist deutlich ausgeprägter als bei kürzeren. So ist bei ähnlicher Verringerung des Gitterüberlappes bei einem 900 μm langen Bauteil eine Linienbreitenreduzierung um einen Faktor von „nur“ 1,85 beobachtbar, aber bei der doppelten Kavitätslänge ist dieser Faktor schon auf 3,60 angestiegen. Im Rahmen dieser Arbeit wurden DFB-Laser hergestellt, die eine Linienbreite von bis zu 198 kHz aufwiesen. Dies stellt für lateral komplexgekoppelte Laser einen absoluten Rekordwert dar. Im Vergleich zu Index-DFB-Lasern ist dieser Wert bzgl. der Linienbreite mit den aktuellsten Ergebnissen aus der Forschung zu vergleichen [CTR+11], bei welchen eine Linienbreite zu 200 kHz bestimmt wurde. In dem letzten Abschnitt dieser Arbeit wurde der Einfluss einer veränderten Phasenlage von Gitter und Facette untersucht. Dabei wurden spezielle Bauteile hergestellt (3-Segment-DFB-Laser) und verschiedene Gitterlängen untersucht. Die Phasenlage kann reversibel über den eingestellten Strom in den gitterfreien Segmenten geregelt werden. Wie vorhergesagt, bestätigen die Experimente, dass diese Phasenbeziehung einen signifikanten Einfluss auf die Ausgangsleistung, die Wellenlänge mit ihrer zugehörigen Seitenmodenunterdrückung und auch auf die Linien-breite hat. Bei der Analyse der Linienbreite konnte eindeutig beobachtet werden, dass für die verschiedenen Längen die inverse Linienbreite sehr gut mit der relativen Seitenmodenunterdrückung gekoppelt ist. Dies stellt eine deutliche Erleichterung der zukünftigen Optimierung der komplexgekoppelten DFB-Laser dar, da eine Linienbreitenuntersuchung meist deutlich zeitaufwendiger ist als eine Analyse mit einem optischen Spektrometer. N2 - The goal of this thesis was to analyze and improve the characteristics of complex-coupled DFB-lasers due to their use for metrological investigations. For this purpose, the spatial properties of the laterally complex-coupled DFB-lasers were discussed in extensive studies. It has been explained why the asymmetry of the far field for this special type of laser diode is typically quite high due to the required coupling strength. For commercially available lasers, the far field was calculated in both lateral and vertical direction. The corresponding far field measurements proofed the theory, and as expected, the divergence angles of 52° FWHM in the epitaxial direction and 12° FWHM in lateral direction (see fig. 6.4 and 6.5) showed very huge differences and confirmed the predicted high far field asymmetry. The layer stack was optimized first with regard to the optical and electrical confinement potential to change the far field situation. The far field in the epitaxial direction has been reduced by more than 50% to a value of 25° FWHM. As a result, the asymmetry of the far field could be reduced by a factor of more than 4. Beam profile measurements showed a nearly diffraction limited Gaussian beam profile in the slow axis with a M2-value of 1.13 (fig. 6.3). Additional investigations were done to determine the dependency between the linewidth of such lasers and their optical output power, resonator length, facet reflectivity and grating coupling strength. The first study was related to the narrowing of the linewidth due to the increased optical output power ending up in a rebroadening (compare fig. 7.3). The influence of the resonator length to the linewidth was very close to theory and thus a doubling of the resonator length led to a linewidth narrowing of more than factor 3. Increasing the cavity length did not favour the negative effect of the so-called rebroadening since the portion of index coupling within the used lateral complex-coupling technology is very small. In case of pure index coupling the influence due to the changed κ·L-condition would be increased. A further advantage of the complex-coupling mentioned above is the fact that the influence of the facet reflectivities on the DFB yield and laser characteristics is significantly smaller compared to pure index coupling. This can be used to increase the photon lifetime in the cavity without decreasing the DFB yield. The influence on the linewidth of as-cleaved facets was compared to coated ones with lasers of different length. The front facet was passivated to hold the as-cleaved reflectivity of about 30%, and the rear facet was coated with a layer stack to end up at about 85% reflectivity. The linewidth was more than halved. In addition to these results, the influence of complex-coupling was also investigated. As extra losses are introduced by the grating itself, the frequency noise, produced by a higher geometric overlap of the grating with the lasing mode will rise. This could also be confirmed in the experiment. It was also observed that this effect has a length driven component. Narrowing the linewidth by reducing the grating overlap has a higher influence on a longer device compared to shorter laser diodes. A factor of 1.85 on a 900 μm long device has been observed, but diodes with doubled length showed a factor of 3.60. Within the scope of this thesis, DFB-lasers were produced showing linewidths down to 198 kHz. Regarding complex-coupled laser diodes, this value for the linewidth is an absolute record. Compared to index-coupled DFB-lasers, this value matches to latest research findings [CTR+11]. In the last chapter of this work the influence of the phasing of grating and facet was discussed. Special laser diodes (3-segment DFB-lasers) with different grating lengths were produced. The phasing was determined by the injection current of the grating-free segments. As predicted, the experimental results proved the significant influence of the phasing to output power, wavelength including SMSR and the linewidth. It was also observed that for different lengths the inverse linewidth is proportional to the SMSR. This relationship could be used for improved and faster optimization of complex-coupled DFB-lasers as an investigation of the linewidth is typically more complex than a simple analysis on an optical spectrometer. KW - DFB-Laser KW - Metrologie KW - komplexe Gitterkopplung KW - Linienbreite KW - Atomuhr Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159618 ER - TY - THES A1 - Ziener, Christian H. T1 - Suszeptibilitätseffekte in der Kernspinresonanzbildgebung T1 - Susceptibility effects in nuclear magnetic resonance imaging N2 - Das Dephasierungsverhalten und die daraus resultierende Relaxation der Magnetisierung sind Grundlage aller auf der Kernspinresonanz basierenden bildgebenden Verfahren. Das erhaltene Signalder präzedierenden Protonen wird wesentlich von den Eigenschaften des untersuchten Gewebes bestimmt. Insbesondere die durch magnetisierte Stoffe wie z. B. desoxygeniertes Blut (BOLD-Effekt) oder magnetische Nanopartikel erzeugten Suszeptibilitätssprünge gewinnen zunehmend Bedeutung in der biomedizinischen Bildgebung. In der vorliegenden Arbeit wurden die Einflüsse von Feldinhomogenitäten auf das NMR-Signal untersucht. N2 - The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed. KW - Magnetische Kernresonanz KW - Magnetische Suszeptibilität KW - NMR-Bildgebung KW - nuclear magnetic resonance KW - magnetic susceptibility KW - magnetic resonance imaging Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-35425 ER - TY - THES A1 - Zeller, Wolfgang T1 - Entwicklung und Charakterisierung von Hochleistungslaserdioden bei 980 nm Wellenlänge T1 - Development and characterization of high-power laser diodes at 980 nm wavelength N2 - Ziel der Arbeit war die Entwicklung von lateral gekoppelten DFB-Halbleiterlasern für Hochleistungsanwendungen. Besonderes Augenmerk war dabei auf hohe COD-Schwellen und schmale Fernfeldverteilungen gerichtet. Ausgehend von einem LOC-Design wurden Simulationsrechnungen durchgeführt und ein neues Epitaxiedesign mit einer 2.5 μm dicken LOC, in welcher die aktive Schicht asymmetrisch positioniert ist, entwickelt. Durch die asymmetrische Anordnung der aktiven Schicht kann die im Falle von lateral gekoppelten DFB-Lasern sehr kritische Kopplung der Lichtmode an das modenselektive Gitter gewährleistet werden. Zudem reichen die Ausläufer der Lichtmode in diesem Design weiter in den Wellenleiter hinab als dies bei herkömmlichen Wellenleitern der Fall ist, so dass sich die Fernfeldeigenschaften der Laser verbessern. Die Fernfeldverteilungen solcher Laser weisen Halbwertsbreiten von 14° in lateraler und nur 19° in transversaler Richtung auf. Im Vergleich mit Standardstrukturen konnte die Ausdehnung des transversalen Fernfeldes also um mehr als 50 % reduziert werden. Außerdem ergibt sich eine nahezu runde Abstrahlcharakteristik, was die Einkopplungseffizienz in optische Systeme wie Glasfasern oder Linsen signifikant verbessert. Unter Ausnutzung der entwickelten Epitaxiestruktur mit asymmetrischer LOC wurde ein neues Lateraldesign entwickelt. Es handelt sich hierbei um Wellenleiterstege welche im Bereich der Facetten eine Verjüngung aufweisen. Durch diese wird die optische Mode tief in die 2.5 μm dicke Wellenleiterschicht geführt, welche sie in transversaler Richtung komplett ausfüllt. Durch den größeren Abstand der Lasermode vom Wellenleitersteg ergibt sich zudem eine deutliche schwächere laterale Führung, so dass sich die Mode auch parallel zur aktiven Schicht weiter ausdehnt. Die Lichtmode breitet sich folglich über eine deutlich größere Fläche aus, als dies bei einem gleichbleibend breiten Wellenleitersteg der Fall ist. Die somit signifikant kleinere Leistungsdichte auf der Laserfacette ist gleichbedeutend mit einem Anstieg der COD-Schwelle der Laser der im Einzelnen von den jeweiligen Designparametern von Schicht- und Lateralstruktur abhängig ist. Außerdem bewirkt die in lateraler und transversaler Richtung deutlich schwächere Lokalisation der Mode eine weitere Abnahme der Halbwertsbreiten der Laserfernfelder. Durch die im Vergleich zu herkömmlichen Laserstrukturen schwächere Lokalisation der Lichtmode im Bereich der Facetten ergeben sich äußerst schmale Fernfelder. Ein 1800 μm langer Laser, dessen Stegbreite über 200 μm hinweg auf 0.4 μm verringert wurde, zeigt Halbwertsbreiten von 5.2° in lateraler und 13.0° in transversaler Richtung. Damit sind die Fernfelder dieser Laser bedeutend kleiner als die bislang vorgestellter Laserdioden mit LOC. Die Geometrie der Taperstrukturen bestimmt, wie vollständig sich die Mode in den unteren Wellenleiterbereich ausbreiten kann und nimmt damit Einfluss auf die Laserfernfelder. Im CW-Modus durchgeführte Messungen an Lasern mit Taperstrukturen zeigen maximale Ausgangsleistung von 200 mW bevor die Laser in thermisches Überrollen übergehen. Bei einer Ausgangsleistung von 185 mW beträgt das Seitenmodenunterdrückungsverhältnis 33 dB. Im gepulsten Modus (50 ns Pulsdauer, 1MHz Wiederholungsrate) betriebene Laser zeigen hohe COD-Schwellen von mehreren hundert bis hin zu 1600 mW, die eine deutliche Abhängigkeit von der Endbreite der Taperstrukturen zeigen: Mit abnehmender Taperbreite ergibt sich eine starke Zunahme der COD-Schwelle. An einem 1800 μm langen Laser mit 200 μm langen Taperstrukturen die eine Endbreite von 0.3 μm aufweisen konnte eine COD-Schwelle von 1.6 W nachgewiesen werden. Im Gegensatz zu anderen Ansätzen, die ebenfalls longitudinal und lateral mono-modige DFB-Laser mit hohen Ausgangsleistungen zum Ziel haben, kann jedoch bei dem hier präsentierten Konzept aufgrund des Einsatzes von lateralen DFB-Gittern auf eine Unterbrechung des epitaktischen Wachstums verzichtet werden. Dies vereinfacht die Herstellung der Schichtstrukturen deutlich. Die hier vorgestellten Konzepte sind mit weiteren üblichen Vorgehensweisen zur Herstellung von Hochleistungslaserdioden, wie z.B. speziellen Facettenreinigungs- und Passivierungsverfahren oder Materialdurchmischung im Facettenbereich, kombinierbar. Zudem kann das hier am Beispiel des InGaAs/GaAs Materialsystems entwickelte Konzept auf alle zur Herstellung von Halbleiterlaserdioden üblichen Materialsysteme übertragen werden und eröffnet so eine völlig neue, material- und wellenlängenunabhängige Möglichkeit Abstrahlcharakteristik und Ausgangsleistung von Laserdioden zu optimieren. N2 - The primary objective of this work was the development of laterally coupled DFB semiconductor laser diodes for high-power applications. Special attention was turned to high COD thresholds and narrow farfield distributions. Based on a LOC design, simulations were undertaken and a new epitaxial design was devised featuring an active layer positioned asymmetrically in a LOC with a height of 2.5 μm. This design guarantees good coupling between the light mode and the lateral grating, something that is especially critical in the case of laterally coupled DFB lasers. Furthermore, due to this design the fringes of the light mode extend farther into the waveguide layers than possible in conventional waveguides, thereby improving the farfield characteristics of the devices. The farfield distributions of these laser diodes exhibit FWHM values of 14° in lateral and only 19° in transversal direction. Compared to standard designs the dimension of the transversal farfield could be reduced by more than 50 %, resulting in an almost circular farfield pattern, hence improving the coupling efficiency into optical fibers or lenses significantly. Based on the developed epitaxial design with an asymmetrical LOC, a new ridge design was devised. It features RWGs that are tapered down to a width of only several hundred nanometers at both ends of the laser cavity. Due to this tapered sections, the optical mode is pushed down into the 2.5 μm thick waveguide, filling it out completely in transversal direction. Because of the increased distance between the lasing mode and the RWG, the lateral mode guiding is also decreased, resulting in an expansion parallel to the epitaxial layers as well. Consequently the light spreads over a significantly larger area than in the case of a RWG of constant width. The thusly reduced power density at the laser facet is tantamount to an increase in COD threshold the extent of which depends on the particular design parameters of layer and ridge design respectively. Furthermore, the weaker localisation of the light mode causes a further decrease of the farfields’ FWHM values. Due to the localisation of the light mode being weaker than in conventional laser structures, the measured lasers’ farfield distributions are very narrow. A 1800 μm long laser with a 2.0 μm wide RWG tapered down to 0.4 μm over a length of 200 μm yields FWHM values of 5.2° in lateral and 13.0° in transversal direction. These values are considerably smaller than those achieved with other laser diodes based on LOC structures presented up to now. The layout of the taper structures determines the degree of the spread into the lower waveguide and therefore influences the farfield distributions. When measured in CW mode, the tapered lasers show a maximum optical output power of 200 mW before exhibiting thermal roll-over. Measured at an output power of 185 mW, the spectral characteristics yield a SMSR of 33 dB. Operated in pulsed mode (50 ns pulse length, 1 MHz repetition rate), the laser diodes show high COD thresholds of several hundred up to 1600 mW. The COD thresholds exhibit a strong dependence on the taper width viz. a fast increase of COD threshold with decreasing taper width. Data derived from measurements conducted with a 1800 μm long laser that was tapered down to a ridge width of only 0.3 μm over a length of 200 μm, yield a COD threshold of 1.6 W. Other approaches aiming at laterally and longitudinally mono-mode high-power DFB lasers are based on an epitaxial overgrowth step. This highly risky procedure could be foregone due to the use of DFB gratings positioned laterally to the RWG. The concepts presented here are fully compatible with other procedures usually used for manufacturing high power laser diodes with high COD thresholds, such as special facet cleaning and passivation procedures or quantum-well-intermixing. Above all, although the concept developed in this work was based on the InGaAs/GaAs material system, it can be transferred to virtually every material system used for the fabrication of semiconductor laser diodes. Thus the presented concept establishes a new way of optimizing both farfield and output power of laser diodes that is independent of both material system and emission wavelength. KW - DFB-Laser KW - mono-mode laser KW - quantum-well laser KW - DFB laser KW - high-power laser KW - large optical cavity KW - tapered laser KW - Einmodenlaser KW - Quantenwell-Laser KW - Quantenpunktlaser KW - Galliumarsenidlaser Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-73409 ER - TY - THES A1 - Zapf, Michael T1 - Oxidische Perovskite mit Hoher Massenzahl Z: Dünnfilmdeposition und Spektroskopische Untersuchungen T1 - High-Z Perovskite Oxides: Thin Film Deposition and Spectroscopic Investigations N2 - Perovskite oxides are a very versatile material class with a large variety of outstanding physical properties. A subgroup of these compounds particularly tempting to investigate are oxides involving high-\(Z\) elements, where spin-orbit coupling is expected to give rise to new intriguing phases and potential application-relevant functionalities. This thesis deals with the preparation and characterization of two representatives of high-\(Z\) oxide sample systems based on KTaO\(_3\) and BaBiO\(_3\). KTaO\(_3\) is a band insulator with an electronic valence configuration of Ta 5\(d\)\(^0\) . It is shown that by pulsed laser deposition of a disordered LaAlO\(_3\) film on the KTaO\(_3\)(001) surface, through the creation of oxygen vacancies, a Ta 5\(d\)\(^{0+\(\delta\)}\) state is obtained in the upmost crystal layers of the substrate. In consequence a quasi two dimensional electron system (q2DES) with large spin-orbit coupling emerges at the heterointerface. Measurements of the Hall effect establish sheet carrier densities in the range of 0.1-1.2 10\(^{14}\) cm\(^2\), which can be controlled by the applied oxygen background pressure during deposition and the LaAlO\(_3\) film thickness. When compared to the prototypical oxide q2DESs based on SrTiO\(_3\) crystals, the investigated system exhibits exceptionally large carrier mobilities of up to 30 cm\(^2\)/Vs (7000 cm\(^2\)/Vs) at room temperature (below 10 K). Through a depth profiling by photoemission spectra of the Ta 4\(f\) core level it is shown that the majority of the Ta 5\(d\)\(^0\) charge carriers, consisting of mobile and localized electrons, is situated within 4 nm from the interface at low temperatures. Furthermore, the momentum-resolved electronic structure of the q2DES \(buried\) underneath the LaAlO\(_3\) film is probed by means of hard X-ray angle-resolved photoelectron spectroscopy. It is inferred that, due to a strong confinement potential of the electrons, the band structure of the system is altered compared to \(n\)-doped bulk KTO. Despite the constraint of the electron movement along one direction, the Fermi surface exhibits a clear three dimensional momentum dependence, which is related to a depth extension of the conduction channels of at least 1 nm. The second material, BaBiO\(_3\), is a charge-ordered insulator, which has recently been predicted to emerge as a large-gap topological insulator upon \(n\)-doping. This study reports on the thin film growth of pristine BaBiO\(_3\) on Nb:SrTiO\(_3\)(001) substrates by means of pulsed laser deposition. The mechanism is identified that facilitates the development of epitaxial order in the heterostructure despite the presence of an extraordinary large lattice mismatch of 12 %. At the heterointerface, a structurally modified layer of about 1.7 nm thickness is formed that gradually relieves the in-plane strain and serves as the foundation of a relaxed BBO film. The thereupon formed lattice orders laterally in registry with the substrate with the orientation BaBiO\(_3\)(001)||SrTiO\(_3\)(001) by so-called domain matching, where 8 to 9 BaBiO\(_3\) unit cells align with 9 to 10 unit cells of the substrate. Through the optimization of the deposition conditions in regard to the cation stoichiometry and the structural lattice quality, BaBiO\(_3\) thin films with bulk-like electronic properties are obtained, as is inferred from a comparison of valence band spectra with density functional theory calculations. Finally, a spectroscopic survey of BaBiO\(_3\) samples of various thicknesses resolves that a recently discovered film thickness-controlled phase transition in BaBiO\(_3\) thin films can be traced back to the structural and concurrent stoichiometric modifications occuring in the initially formed lattice on top of the SrTiO\(_3\) substrate rather than being purely driven by the smaller spatial extent of the BBO lattice. N2 - Komplexe Metalloxide mit Perowskitstruktur sind bekannt für ihre große Vielfalt einzigartiger physikalischer Eigenschaften. Eine interessante Untergruppe dieser Materialien sind Verbindungen von Elementen mit hoher Ordnungszahl \(Z\), in denen neue, durch Spin-Bahn Kopplung getriebene Phasen und anwendungsrelevante Funktionalitäten erwartet werden. Diese Arbeit handelt von der Präparation und Charakterisierung zweier Probensysteme, die auf eben solchen Materialien mit hoher \(Z\) basieren. KTaO\(_3\) ist ein Bandisolator, der im Grundzustand eine Ta 5\(d\)\(^0\) Valenz besitzt. Durch gepulste Laserdeposition von ungeordnetem LaAlO\(_3\) auf der KTaO\(_3\)(001) Oberfläche, werden die obersten Schichten des Substratkristalls durch die Erzeugung von Sauerstofffehlstellen dotiert. Es bildet sich ein quasi zweidimensionales metallisches Elektronensystem (q2DES) an der Grenzfläche der Heterostruktur aus. Messungen des Hall-Effekts ergeben Schichtladungsträgerdichten im Bereich von 0.1-1.2 10\(^{14}\) cm\(^2\), welche durch Anpassung des Sauerstoffhintergrunddrucks während der Deposition bzw. durch die Dicke der abgeschiedenen LaAlO\(_3\) Schicht beeinflusst werden können. Mit Werten von 30 cm\(^2\)/Vs (7000 cm\(^2\)/Vs) bei Raumtemperatur (unter 10 K), besitzt das q2DES in LaAlO\(_3\)/KTaO\(_3\) im Vergleich zu ähnlichen Elektronensystemen in SrTiO\(_3\) bemerkenswert große Ladungsträgerbeweglichkeiten. Aus dem Tiefenprofil des Photoemissionspektrums des Ta 4\(f\) Rumpfniveaus ergibt sich, dass sich der Großteil der Ta 5\(d\) Ladungsträger, bestehend aus mobilen und lokalisierten Elektronen, innerhalb einer Schicht von 4 nm Dicke befindet. Die Vermessung der elektronischen Bandstruktur des vergrabenen q2DES mit Hilfe winkelaufgelöster Photoelektronenspektroskopie mit harter Röntgenstrahlung zeigt, dass das Elektronensystem, vermutlich wegen des starken Potentialgradients an der Grenzfläche, eine modifizierte elektronische Struktur gegenüber n-dotiertem Bulk-KTaO\(_3\) aufweist. Trotz der Einschränkung der Bewegung der Elektronen entlang einer Richtung, besitzt die Fermifläche des Systems eine dreidimensionale Struktur, woarus auf eine Tiefenausdehnung der metallischen Zustände von mindestens 1 nm geschlossen werden kann. Undotiertes BaBiO\(_3\) ist durch die Ausbildung einer Ladungsordnung isolierend. Unter Elektronendotierung gilt das Material als Kandidat für einen oxidischen topologischen Isolator. In dieser Studie wird die Deposition von BaBiO\(_3\) auf Nb:SrTiO\(_3\)(001) Substraten untersucht. Dabei wird der Mechanismus identifiziert, der epitaktisches Wachstum von BaBiO\(_3\), trotz einer Gitterfehlanpassung von 12 %, ermöglicht: Eine 1.7 nm dicke Lage mit abweichender Kristallstruktur an der Grenzfläche entkoppelt das Filmgitter vom Substrat, sodass darüber vollständig relaxiertes BaBiO\(_3\) aufwachsen kann. Dieses weist eine epitaktische Orientierung von BaBiO\(_3\)(001)||SrTiO\(_3\)(001) auf, die durch die Ausbildung von lateralen Gitterdomänen, bei denen 8 bzw. 9 BaBiO\(_3\) auf 9 bzw. 10 SrTiO\(_3\) Einheitszellen ausgerichtet sind, gewährleistet wird. Die Stoichiometrie und die strukturelle Qualität der BaBiO\(_3\) Filme werden durch eine systematische Anpassung der Depositionsbedingungen optimiert. Die Valenzbandstruktur der Proben stimmt gut mit Rechnungen der Dichtefunktionaltheorie überein, was darauf hindeutet, dass die Filme hinsichtlich der elektronischen Eigenschaften mit BaBiO\(_3\) Einkristallen vergleichbar sind. Eine abschließende Untersuchung eines schichtdickenabhängigen Phasenübergangs in BaBiO\(_3\) Dünnfilmen, von dem kürzlich in der Literatur berichtet wurde, belegt, dass dieser nicht allein auf die Ausdehnung des Kristallgitters, sondern auch auf strukturelle und stoichiometrische Modifikationen der untersten Filmlagen zurückzuführen ist. KW - Perowskit KW - Röntgen-Photoelektronenspektroskopie KW - Pulsed laser deposition KW - Übergangsmetalloxide KW - KTaO3 KW - BaBiO3 KW - Oxide Heterostructure KW - Interface Conductivity KW - oxidische Heterostruktur KW - Grenzflächenleitfähigkeit KW - Winkelaufgelöste Photoemission mit harten Röntgenstrahlen KW - Hard X-ray Angle Resolved Photoemission KW - High-Z Oxides KW - HARPES Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-185370 ER - TY - THES A1 - Youssef, Almoatazbellah T1 - Fabrication of Micro-Engineered Scaffolds for Biomedical Application T1 - Fabrikation von Scaffolds mit optimierter Mikroarchitektur für biomedizinische Anwendungen N2 - Thermoplastic polymers have a history of decades of safe and effective use in the clinic as implantable medical devices. In recent years additive manufacturing (AM) saw increased clinical interest for the fabrication of customizable and implantable medical devices and training models using the patients’ own radiological data. However, approval from the various regulatory bodies remains a significant hurdle. A possible solution is to fabricate the AM scaffolds using materials and techniques with a clinical safety record, e.g. melt processing of polymers. Melt Electrowriting (MEW) is a novel, high resolution AM technique which uses thermoplastic polymers. MEW produces scaffolds with microscale fibers and precise fiber placement, allowing the control of the scaffold microarchitecture. Additionally, MEW can process medical-grade thermoplastic polymers, without the use of solvents paving the way for the production of medical devices for clinical applications. This pathway is investigated in this thesis, where the layout is designed to resemble the journey of a medical device produced via MEW from conception to early in vivo experiments. To do so, first, a brief history of the development of medical implants and the regenerative capability of the human body is given in Chapter 1. In Chapter 2, a review of the use of thermoplastic polymers in medicine, with a focus on poly(ε-caprolactone) (PCL), is illustrated, as this is the polymer used in the rest of the thesis. This review is followed by a comparison of the state of the art, regarding in vivo and clinical experiments, of three polymer melt AM technologies: melt-extrusion, selective laser sintering and MEW. The first two techniques already saw successful translation to the bedside, producing patient-specific, regulatory-approved AM implants. To follow in the footsteps of these two technologies, the MEW device parameters need to be optimized. The MEW process parameters and their interplay are further discussed in Chapter 3 focusing on the importance of a steady mass flow rate of the polymer during printing. MEW reaches a balance between polymer flow, the stabilizing electric field and moving collector to produce reproducible, high-resolution scaffolds. An imbalance creates phenomena like fiber pulsing or arcing which result in defective scaffolds and potential printer damage. Chapter 4 shows the use of X-ray microtomography (µCT) as a non-destructive method to characterize the pore-related features: total porosity and the pore size distribution. MEW scaffolds are three-dimensional (3D) constructs but have long been treated in the literature as two-dimensional (2D) ones and characterized mainly by microscopy, including stereo- and scanning electron microscopy, where pore size was simply reported as the distance between the fibers in a single layer. These methods, together with the trend of producing scaffolds with symmetrical pores in the 0/90° and 0/60/120° laydown patterns, disregarded the lateral connections between pores and the potential of MEW to be used for more complex 3D structures, mimicking the extracellular matrix. Here we characterized scaffolds in the aforementioned symmetrical laydown patterns, along with the more complex 0/45/90/135° and 0/30/60/90/120/150° ones. A 2D pore size estimation was done first using stereomicroscopy, followed by and compared to µCT scanning. The scaffolds with symmetrical laydown patterns resulted in the predominance of one pore size, while those with more complex patterns had a broader distribution, which could be better shown by µCT scans. Moreover, in the symmetrical scaffolds, the size of 3D pores was not able to reach the value of the fiber spacing due to a flattening effect of the scaffold, where the thickness of the scaffold was less than the fiber spacing, further restricting the pore size distribution in such scaffolds. This method could be used for quality assurance of fabricated scaffolds prior to use in in vitro or in vivo experiments and would be important for a clinical translation. Chapter 5 illustrates a proof of principle subcutaneous implantation in vivo experiment. MEW scaffolds were already featured in small animal in vivo experiments, but to date, no analysis of the foreign body reaction (FBR) to such implants was performed. FBR is an immune reaction to implanted foreign materials, including medical devices, aimed at protecting the host from potential adverse effects and can interfere with the function of some medical implants. Medical-grade PCL was used to melt electrowrite scaffolds with 50 and 60 µm fiber spacing for the 0/90° and 0/60/120° laydown patterns, respectively. These implants were implanted subcutaneously in immunocompetent, outbred mice, with appropriate controls, and explanted after 2, 4, 7 and 14 days. A thorough characterization of the scaffolds before implantation was done, followed by a full histopathological analysis of the FBR to the implants after excision. The scaffolds, irrespective of their pore geometry, induced an extensive FBR in the form of accumulation of foreign body giant cells around the fiber walls, in a manner that almost occluded available pore spaces with little to no neovascularization. This reaction was not induced by the material itself, as the same reaction failed to develop in the PCL solid film controls. A discussion of the results was given with special regard to the literature available on flat surgical meshes, as well as other hydrogel-based porous scaffolds with similar pore sizes. Finally, a general summary of the thesis in Chapter 6 recapitulates the most important points with a focus on future directions for MEW. N2 - Thermoplastische Polymere werden seit Jahrzehnten erfolgreich in der Klinik eingesetzt und für die Herstellung von Medizinprodukten verwendet. Vorangetrieben durch das zunehmende klinische Interesse an additiven Fertigungsverfahren, z.B. zur Herstellung patientenspezifischer Trainingsmodelle und implantierbarer Medizinprodukte, rücken thermoplastische Materialien noch mehr in den Fokus der klinischen Forschung. Allerdings stellt die Marktzulassung durch die verschiedenen Gesundheitsbehörden eine große Hürde dar. Eine mögliche Lösung ist die Gerüstfabrikation mit Materialien und Verfahren, die bereits etablierte Sicherheitsstandards durchlaufen haben, z. B. die Schmelzverarbeitung der Polymere. Ein neuartiges und hochauflösendes additives Fertigungsverfahren, welches die Verarbeitung von Thermoplasten ermöglicht, ist Melt Electrowriting (MEW). Mittels MEW lassen sich Gerüste, die aus Fasern mit Durchmessern im Mikrometerbereich zusammengesetzt sind, herstellen. Neben der hohen Kontrolle über den Faserdurchmesser ermöglicht MEW auch eine genaue Ablage der Fasern und erlaubt dadurch, die Mikroarchitektur der Konstrukte vorzugeben. Zudem kann das Verfahren medizinisch zugelassene thermoplastische Polymere ohne die Verwendung von Lösungsmitteln verarbeiten und ist somit für die Herstellung medizinischer Produkte sehr relevant. Diese Relevanz sollte im Rahmen der vorliegenden Dissertation evaluiert werden, indem der Weg, den ein Medizinprodukt von der Konzeption bis hin zu in vivo Vorversuchen durchlaufen muss, anhand von Konstrukten, die mittels MEW hergestellt wurden, nachgeahmt wurde. Um eine Basis für das Verständnis dieses Prozesses zu schaffen, wird in Kapitel 1 erst die Geschichte der Entwicklung medizinischer Implantate zusammengefasst sowie ein Einblick in die regenerativen Fähigkeiten des menschlichen Körpers gegeben. Das zweite Kapitel befasst sich mit der Anwendung von thermoplastischen Polymeren im Bereich implantierbarer Medizinprodukte, wobei der Hauptfokus auf Poly(ε-caprolactone) (PCL) liegt, da dies der in der vorliegenden Arbeit verwendete Thermoplast ist. Es folgt ein Vergleich von in vivo sowie klinischen Versuchen dreier für die Biomedizin relevanten additiven Fertigungsverfahren, mit denen sich thermoplastische Polymere verarbeiten lassen: Die Mikro-Schmelzextrusion, das selektive Lasersintern und das MEW. Die ersten zwei Verfahren sind bereits erfolgreich in klinischen Anwendungen etabliert und ermöglichen die routinemäßige Herstellung von additiv gefertigten, patientenspezifischen, auf dem Markt zugelassenen Implantaten. Damit MEW in diese Fußstapfen treten kann, müssen die Prozessparameter und deren Zusammenspiel genau analysiert werden. Dieser Thematik widmet sich Kapitel 3, wobei die Untersuchung des Massendurchsatzes des Polymers während des Druckens diskutiert wird. Um den MEW-Prozess kontrollieren zu können, muss eine Balance zwischen Polymerdurchsatz, dem stabilisierenden elektrischen Feld und dem beweglichen Kollektor erreicht werden. Dies ist Grundlage für die reproduzierbare Herstellung hochaufgelöster Konstrukte. Ein Ungleichgewicht der Prozessparameter verursacht Phänomene wie Fiber Pulsing oder sogar elektrischen Durchschlag, welche zu defekten Konstrukten oder sogar zur Schädigung des Druckers führen können. Kapitel 4 zeigt die Anwendung der Röntgenmikrocomputertomographie (µCT) als eine zerstörungsfreie Charakterisierungsmethode für MEW-Konstrukte, die die Quantifizierung charakteristischer Eigenschaften wie der Porosität und der Porengrößenverteilung ermöglicht. MEW-Konstrukte wurden in der Literatur lange als zweidimensional behandelt und hauptsächlich durch mikroskopische Verfahren wie die Stereo- und Rasterelektronmikroskopie charakterisiert. Die zweidimensionale Porengröße wurde hauptsächlich durch die Bestimmung des Faserabstands definiert und daraus errechnet, mit einer Tendenz der Herstellung der Konstrukte mit symmetrischen Poren in 0/90° und 0/60/120° Ablagemustern. Da es sich bei den Konstrukten jedoch um dreidimensionale (3D) Fasergerüste handelt, wurden die seitlichen Verbindungen zwischen den Poren und das Potential der Anwendung des MEW für die Herstellung von komplexeren 3D-Strukturen, wie bei der extrazellulären Matrix mit interkonnektierenden Poren, vernachlässigt. Aus diesem Grund wurden in der vorliegenden Arbeit µCT-Scans verwendet, um die Porosität der Konstrukte besser wiedergeben zu können. Hierzu wurden verschiedene Ablagemuster mit symmetrischen Poren in 0/90° und 0/60/120° Mustern und komplexere Porenstrukturen durch Ablagen von 0/45/90/135° und 0/30/60/90/120/150° Geometrien hergestellt. Diese Konstrukte wurden dann mittels mikroskopischer und tomographischer Aufnahmen charakterisiert und die Ergebnisse miteinander verglichen. Es zeigte sich, dass symmetrische Ablagemuster zu Konstrukten mit der Prädominanz einer Porengröße geführt haben. Bei den komplexeren Strukturen ergab sich jedoch ein klarer Unterschied, weil die interkonnektierenden Poren nur mit Hilfe von µCT-Scans erfasst werden konnten. Dies zeigte sich durch eine breitere Porenverteilung bei der Auswertung der rekonstruierten Scans. Die Porengrößen in den Konstrukten mit den symmetrischen Mustern konnten aufgrund einer Verflachungswirkung nicht die des Faserabstands erreichen. Die Dicke der Konstrukte war geringer als der Faserabstand mit einer weiteren einschränkenden Wirkung auf die Porenverteilung in den symmetrischen Konstrukten. µCT kann deshalb für die Qualitätssicherung von medizinischen Produkten, die mittels MEW hergestellt wurden, eingesetzt werden. Da die Methode zerstörungsfrei ist, könnte sie auch vor in vitro oder in vivo Versuchen verwendet werden. Kapitel 5 präsentiert eine Machbarkeitsstudie eines subkutanen in vivo Implantationsversuchs. Aus der Literatur ist zwar bekannt, dass MEW-Konstrukte bereits in vivo in Kleintierversuchen verwendet wurden, eine Analyse der Fremdkörperreaktion (FKR) zu solchen Implantaten wurde bisher jedoch noch nicht durchgeführt. FKR ist eine Immunreaktion gegen fremde, implantierte Materialien, einschließlich medizinischer Geräte, um den Wirt vor potenziellen Nebenwirkungen zu schützen. Allerdings könnte sie die Funktion verschiedener medizinischer Implantate beeinträchtigen Um dieser Fragestellung nachzugehen, wurde im Rahmen der vorliegenden Dissertation PCL mittels MEW zu Konstrukten mit 50 und 60 µm Fiberabstand in 0/90° bzw. 0/60/120° Ablagemuster verarbeitet. Diese Konstrukte wurden subkutan in immunkompetente, fremdgezüchtete Mäuse mit entsprechenden Kontrollen implantiert und nach 2, 4, 7 und 14 Tagen explantiert. Vor der Implantation wurde die Konstrukte ausführlich charakterisiert, gefolgt von einer vollen histopathologischen Analyse des FKR. Unabhängig von der Porengeometrie haben die Konstrukte eine deutliche Immunreaktion im Sinne einer Ansammlung von Fremdkörperriesenzellen um die Fasern der Konstrukte hervorgerufen. Hierbei wurden die Poren fast komplett verschlossen, ohne dass es zu einer Neovaskularisation kam. Es konnte nachgewiesen werden, dass die deutliche Immunantwort nicht durch das Material hervorgerufen wurde, da sie bei der Implantation von dichtem PCL-Film nicht beobachtet wurde. Eine Diskussion der Ergebnisse erfolgte unter Berücksichtigung aktueller Literatur zu klinischen Versuchen von flachen chirurgischen Netzen sowie porösen Hydrogel-basierten Implantaten mit vergleichbarer Porengröße. Abschließend wird die Arbeit in Kapitel 6 zusammengefasst und die wichtigsten Punkte rekapituliert. Der Fokus des Kapitels liegt hierbei auf dem zukünftigen Potential des MEW als Fabrikationsmethode für medizinische Produkte. KW - melt electrowriting KW - medical device KW - biomaterials KW - subcutaneous implanation KW - x-ray micro computed tomography Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235457 ER - TY - THES A1 - Wäldchen, Felix T1 - 3D Single Molecule Imaging In Whole Cells Enabled By Lattice Light-Sheet Illumination T1 - 3D Einzelmolekülbildgebung in ganzen Zellen ermöglicht durch Gitterlichtblattbeleuchtung N2 - Single molecule localization microscopy has seen a remarkable growth since its first experimental implementations about a decade ago. Despite its technical challenges, it is already widely used in medicine and biology and is valued as a unique tool to gain molecular information with high specificity. However, common illumination techniques do not allow the use of single molecule sensitive super-resolution microscopy techniques such as direct stochastic optical reconstruction microscopy (dSTORM) for whole cell imaging. In addition, they can potentially alter the quantitative information. In this thesis, I combine dSTORM imaging in three dimensions with lattice lightsheet illumination to gain quantitative molecular information from cells unperturbed by the illumination and cover slip effects. Lattice light-sheet illumination uses optical lattices for beam shaping to restrict the illumination to the detectable volume. I describe the theoretical background needed for both techniques and detail the experimental realization of the system as well as the software that I developed to efficiently evaluate the data. Eventually, I will present key datasets that demonstrate the capabilities of the developed microscope system with and without dSTORM. My main goal here was to use these techniques for imaging the neural cell adhesion molecule (NCAM, also known as CD56) in whole cells. NCAM is a plasma membrane receptor known to play a key role in biological processes such as memory and learning. Combining dSTORM and lattice light-sheet illumination enables the collection of quantitative data of the distribution of molecules across the whole plasma membrane, and shows an accumulation of NCAM at cell-cell interfaces. The low phototoxicity of lattice light-sheet illumination further allows for tracking individual NCAM dimers in living cells, showing a significant dependence of its mobility on the actin skeleton of the cell. N2 - Die Einzelmoleküllokalisationsmikroskopie hat seit der ersten experimentellen Umsetzung vor etwa 10 Jahren einen bemerkenswerten Aufschwung erfahren. Trotz des hohen technischen Anspruchs findet sie bereits weite Verbreitung in der Biologie und Medizin und wird als einzigartiges Werkzeug geschätzt, um molekulare Information mit hoher Spezifität zu erlangen. Dennoch erschweren die gebräuchlichen Beleuchtungsmethoden die Anwendung von Methoden der Einzelmoleküllokalisationsmikroskopie wie dSTORM (engl. direct stochastic optical reconstruction microscopy) auf das Volumen ganzer Zellen, denn hier kann die Beleuchtung selbst die quantitativen Daten beeinflussen. In dieser Arbeit kombiniere ich dreidimensionale dSTORM-Bildgebung mit Gitterlichtblattbeleuchtung (engl. lattice light-sheet illumination) um quantitative, molekulare Information ohne durch die Beleuchtung verursachte Störungen zu gewinnen. Die Gitterlichtblattbeleuchtung nutzt optische Gitter zur Strahlformung, um das beleuchtete Volumen auf das detektierbare Volumen zu beschränken. Ich stelle den nötigen, theoretischen Hintergrund für beide Methoden dar und beschreibe die experimentelle Umsetzung sowie die von mir zur effizienten Datenauswertung entwickelte Software. Schließlich präsentiere ich verschiedene Datensätze, die die Fähigkeiten des Systems mit und ohne dSTORM demonstrieren. Mein Hauptziel war hierbei, beide Methoden zu nutzen, um das neuronale Zelladhäsionsmolekül (NCAM, engl. neural cell adhesion molecule) in ganzen Zellen abzubilden. NCAM (auch bekannt als CD56) ist ein Rezeptor auf der Plasmembran, der für seine Schlüsselrolle im Zusammenhang mit biologischen Prozessen wie Lernen und Gedächtnis bekannt ist. Die Kombination von dSTORM und Gitterlichtblattbeleuchtung ermöglicht das sammeln quantitativer Daten der Verteilung über die komplette Plasmamembran, wobei sich eine Akkumulation an Zell-Zell Kontaktflächen zeigt. Die niedrige Photoschädigung der Gitterlichtblattbeleuchtung ermöglicht weiterhin das Verfolgen von einzelnen NCAM-Dimeren in lebenden Zellen. Dort zeigt sich eine signifikante Abhängigkeit ihrer Mobilität vom Aktinskelett der Zelle. KW - Einzelmolekülmikroskopie KW - Optik KW - Light-Sheet KW - Lattice Light-Sheet KW - dSTORM KW - Single Molecule Imaging KW - Localization Microscopy Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-207111 ER - TY - THES A1 - Wolpert, Daniel T1 - Quantum Control of Photoinduced Chemical Reactions T1 - Quantenkontrolle von photoinduzierten chemischen Reaktionen N2 - The control of quantum mechanical processes, especially the selective manipulation of photochemical reactions by shaped fs laser pulses was successfully demonstrated in many experiments in the fields of physics, chemistry and biology. In this work, attention is directed to the control of two systems that mark a bridge to real synthetic chemistry. In a liquid phase environment the outcome of the photo-induced Wolff rearrangement of an industrially relevant diazonaphthoquinone compound, normally used in photoresists (e.g. Novolak) was optimized using shaped fs laser pulses. In the second series of experiments chemical reactions on a catalyst metal surface which comprise laser induced molecular bond formation channels were selectively manipulated for the first time. The control of liquid phase reactions necessitates adequate spectroscopic signals that are characteristic for the formed product species. Therefore, a pump-probe setup for transient absorption spectroscopy in the mid-infrared for the purpose of investigating ultrafast structural changes of molecules during photoreactions was constructed. This versatile setup enables to monitor structural changes of molecules in the liquid phase and to find appropriate feedback signals for the control of these processes. Prior to quantum control experiments, the photoinduced Wolff-rearrangement reaction of 2-diazo-1-naphthoquinone (DNQ) dissolved in water and methanol was thoroughly investigated. Steady state absorption measurements in the mid-infrared in combination with quantum chemical density functional theory (DFT) calculations revealed the characteristic vibrational bands of DNQ and of possible products. A mid-infrared transient absorption study was performed, to illuminate the structural dynamics of the ultrafast rearrangement reaction of DNQ. The experimental observations indicate, that the Wolff rearrangement reaction of DNQ proceeds within 300 fs. A model for the relaxation dynamics of the ketene photoproduct and DNQ after photoexcitation can be deduced that fits the measured data very well. The object of the quantum control experiments on DNQ was the improvement of the ketene yield. It was shown that the ketene formation after Wolff rearrangement of DNQ is very sensitive to the shape of the applied excitation laser pulses. The variation of single parameters, like the linear chirp as well as the pulse separation of colored double pulses lead to the conclusion that the well known intrapulse dumping mechanism is responsible for the impact of the frequency ordering within the excitation pulse on the photoproduct yield. Adaptive optimizations using a closed learning loop basically lead to the same result. Adaptive fs quantum control was also applied to surface reactions on a catalyst metal surface for the first time. Therefore, the laser-induced catalytic reactions of carbon monoxide (CO) and hydrogen (H2) on a Pd(100) single crystal surface were studied. This photochemical reaction initiated with fs laser pulses has not been observed before. Several product molecules could be synthesized, among them also species (e.g. CH^3+) for whose formation three particles are involved. The systematic variation of different parameters showed that the reactions are sensitive to the catalyst surface, the composition of the adsorbate and to the laser properties. A pump-probe study revealed that they occur on an ultrafast time scale. These catalytic surface reactions were then investigated and improved with phaseshaped fs laser pulses. By applying a feedback optimal control scheme, the reaction outcome could be successfully manipulated and the ratio of different reaction channels could be selectively controlled. Evidence has been found that the underlying control mechanism is nontrivial and sensitive to the specific conditions on the surface. The experiments shown here represent the first successful experiment on adaptive fs quantum control of a chemical reaction between adsorbate molecules on a surface. In contrast to previous quantum control experiments, reaction channels comprising the formation of new molecular bonds rather than the cleavage of already existing bonds are controlled. This work successfully showed that quantum control can be extended to systems closer to situations encountered in synthetic chemistry as was demonstrated in the two examples of the optimization of a complicated rearrangement reaction and the selective formation of chemical bonds with shaped fs laser pulses. N2 - Die Kontrolle quantenmechanischer Prozesse, insbesondere die selektive Manipulation photochemischer Reaktionen mit Hilfe geformter fs-Laserpulse wurde auf den Gebieten der Physik, Chemie und Biologie in vielen Experimenten erfolgreich gezeigt. In dieser Arbeit wird das Augenmerk auf die Kontrolle zweier Systeme gerichtet, die eine Brücke zur synthetischen Chemie darstellen. In der flüssigen Phase wurde das Resultat der photoinduziertenWolff Umlagerung einer industriell relevanten Diazonaphthoquinone Verbindung, die gewöhnlich in Photolacken (z.B. Novolak) Verwendung findet, durch geformte fs-Laserpulse optimiert. In der zweiten Reihe von Experimenten wurden chemische Reaktionen auf einer Katalysator-Metalloberfläche, die Kanäle mit laserinduzierter molekularer Bindungsknüpfung beinhalten, zum ersten Mal selektiv beeinflusst. Für die Kontrolle von Reaktionen in der flüssigen Phase benötigt man geeignete spektroskopische Messsignale, die charakteristisch für die gebildeten Produktspezies sind. Zu diesem Zweck wurde ein Versuchsaufbau für Anrege-Abfrage Experimente zur transienten Absorptionsspektroskopie im mittleren Infrarot aufgebaut, um ultraschnelle strukturelle Veränderungen von Molekülen während Photoreaktionen zu untersuchen. Dieser vielseitige Versuchsaufbau ermöglicht die Messung struktureller Veränderungen in Molekülen in flüssiger Phase und damit das Auffinden geeigneter Rückkopplungssignale zur Kontrolle dieser Prozesse. Vor den Quantenkontrollexperimenten wurde die photoinduzierte Wolff Umlagerung von 2-Diazo-1-Naphthoquinone (DNQ) in den Lösungsmitteln Wasser und Methanol sorgfältig untersucht. Lineare Absorptionsmessungen im mittleren Infrarot in Verbindung mit quantenchemischen Dichtefunktionaltheorie (DFT) Rechnungen lieferten die charakteristischen Schwingungsbanden von DNQ und möglichen Photoprodukten. Untersuchungen mit transienter Absorptionsspektroskopie im mittleren Infrarot wurden durchgeführt, um die strukturelle Dynamik der ultraschnellen Umlagerungsreaktion von DNQ zu beleuchten. Die experimentellen Beobachtungen deuten darauf hin, dass die Wolff Umlagerung von DNQ innnerhalb von 300 fs abläuft. Ein Modell für die Relaxationsdynamik des Keten Photoprodukts und DNQ, dass die gemessenen Daten sehr gut beschreibt wurde abgeleitet. Das Ziel der Quantenkontrollexperimente an DNQ war die Erhöhung der Ketenausbeute. Es wurde gezeigt, dass die Bildung des Keten nach der Wolff Umlagerung des DNQ empfindlich auf die Form der Anregungspulse reagiert. Die Variation einzelner Parameter, wie des linearen Chirps sowie des Pulsabstands von farbigen Doppelpulsen führen zu dem Schluss, dass der gut bekannte Intrapuls-Abregemechanismus verantwortlich für den Einfluss der Frequenzfolge innerhalb des Anregepulses auf die Ausbeute des Photoprodukts ist. Adaptive Optimierungen führen zum gleichen Ergebnis. Adaptive Quantenkontrolle wurde auch erstmalig auf Oberflächenreaktionen auf einer Katalysator-Metalloberfläche angewendet. Dazu wurden die laserinduzierten katalytischen Oberflächenreaktionen von Kohlenmonoxid (CO) und Wasserstoff (H2) auf einer Pd(100) Einkristalloberfläche untersucht. Diese photochemische Reaktion, die durch fs-Laserpulse ausgelöst wird wurde bisher noch nicht beobachtet. Mehrere Produktmoleküle konnten synthetisiert werden, darunter auch Moleküle für deren Bildung mindestens drei Eduktmoleküle zusammenkommen und reagieren müssen. Die systematische Änderung verschiedener Parameter zeigte, dass die Reaktionen von der Katalysatoroberfläche, der Zusammensetzung des Adsorbats und den Eigenschaften der fs-Laserpulse abhängen. Eine Anrege-Abfrage Untersuchung machte deutlich, dass die Reaktionen auf einer ultrakurzen Zeitskala ablaufen. Diese katalytischen Oberflächenreaktionen wurden im Anschluss mit Hilfe von phasengeformten fs-Laserpulsen weiter untersucht und gezielt gesteuert. In adaptiven Quantenkontrollexperimenten konnte das Reaktionsergebnis sowie das Verhältnis unterschiedlicher Reaktionskanäle selektiv manipuliert werden. Es wurden Hinweise gefunden, dass der zugrundeliegende Kontrollmechanismus nichttrivial ist und von den genauen Bedingungen auf der Oberfläche abhängt. Diese Experimente stellen die ersten erfolgreichen adaptiven Quantenkontrollexperimente an einer chemischen Reaktion zwischen Adsorbatmolekülen auf einer Oberfläche dar. Im Gegensatz zu bisherigen Quantenkontrollexperimenten wurden hierbei Reaktionskanäle optimiert, die die Formung und nicht nur den Bruch einer molekularen Bindung umfassen. Diese Arbeit zeigt, dass die Methoden der Quantenkontrolle auf Systeme, die den Situationen in der synthetischen Chemie nahekommen, erfolgreich angewendet werden können, wie mit den zwei Beispielen, der Optimierung einer komplizierten Umlagerungsreaktion und der selektiven Bildung chemischer Bindungen mit geformten fs-Laserpulsen demonstriert wurde. KW - Nichtlineare Spektroskopie KW - Infrarotspektroskopie KW - Massenspektrometrie KW - Laserchemie KW - Femtosekundenpulse KW - Pulsformung KW - Quantenkontrolle KW - quantum control KW - pulse shaping KW - femtosecond pulses KW - time-of-flight mass spectrometry KW - infrared spectroscopy KW - nonlinear spectroscopy Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-27171 ER - TY - THES A1 - Wolf, Nadine T1 - Synthese, Charakterisierung und Modellierung von klassischen Sol-Gel- und Nanopartikel-Funktionsschichten auf der Basis von Zinn-dotiertem Indiumoxid und Aluminium-dotiertem Zinkoxid T1 - Synthesis, characterization and modeling of classical sol gel and nanoparticle functional layers on the basis of indium tin oxide and alumnium zinc oxide N2 - Das Ziel dieser Arbeit ist neben der Synthese von Sol-Gel-Funktionsschichten auf der Basis von transparent leitfähigen Oxiden (transparent conducting oxides, TCOs) die umfassende infrarotoptische und elektrische Charakterisierung sowie Modellierung dieser Schichten. Es wurden sowohl über klassische Sol-Gel-Prozesse als auch über redispergierte Nanopartikel-Sole spektralselektive Funktionsschichten auf Glas- und Polycarbonat-Substraten appliziert, die einen möglichst hohen Reflexionsgrad im infraroten Spektralbereich und damit einhergehend einen möglichst geringen Gesamtemissionsgrad sowie einen niedrigen elektrischen Flächenwiderstand aufweisen. Zu diesem Zweck wurden dotierte Metalloxide, nämlich einerseits Zinn-dotiertes Indiumoxid (tin doped indium oxide, ITO) und andererseits Aluminium-dotiertes Zinkoxid (aluminum doped zinc oxide, AZO)verwendet. Im Rahmen dieser Arbeit wurden vertieft verschiedene Parameter untersucht, die bei der Präparation von niedrigemittierenden ITO- und AZO-Funktionsschichten im Hinblick auf die Optimierung ihrer infrarot-optischen und elektrischen Eigenschaften sowie ihrer Transmission im sichtbaren Spektralbereich von Bedeutung sind. Neben der Sol-Zusammensetzung von klassischen Sol-Gel-ITO-Beschichtungslösungen wurden auch die Beschichtungs- und Ausheizparameter bei der Herstellung von klassischen Sol-Gel-ITO- sowie -AZO-Funktionsschichten charakterisiert und optimiert. Bei den klassischen Sol-Gel- ITO-Funktionsschichten konnte als ein wesentliches Ergebnis der Arbeit der Gesamtemissionsgrad um 0.18 auf 0.17, bei in etwa gleichbleibenden visuellen Transmissionsgraden und elektrischen Flächenwiderständen, reduziert werden, wenn anstelle von (optimierten) Mehrfach-Beschichtungen Einfach-Beschichtungen mit einer schnelleren Ziehgeschwindigkeit anhand des Dip-Coating-Verfahrens hergestellt wurden. Mit einer klassischen Sol-Gel-ITO-Einfach-Beschichtung, die mit einer deutlich erhöhten Ziehgeschwindigkeit von 600 mm/min gedippt wurde, konnte mit einem Wert von 0.17 der kleinste Gesamtemissionsgrad dieser Arbeit erzielt werden. Die Gesamtemissionsgrade und elektrischen Flächenwiderstände von klassischen Sol-Gel-AZOFunktionsschichten konnten mit dem in dieser Arbeit optimierten Endheizprozess deutlich gesenkt werden. Bei Neunfach-AZO-Beschichtungen konnten der Gesamtemissionsgrad um 0.34 auf 0.50 und der elektrische Flächenwiderstand um knapp 89 % auf 65 Ω/sq verringert werden. Anhand von Hall-Messungen konnte darüber hinaus nachgewiesen werden, dass mit dem optimierten Endheizprozess, der eine erhöhte Temperatur während der Reduzierung der Schichten aufweist, mit N = 4.3·1019 cm-3 eine etwa doppelt so hohe Ladungsträgerdichte und mit µ = 18.7 cm2/Vs eine etwa drei Mal so große Beweglichkeit in den Schichten generiert wurden, im Vergleich zu jenen Schichten, die nach dem alten Endheizprozess ausgehärtet wurden. Das deutet darauf hin, dass bei dem optimierten Heizschema sowohl mehr Sauerstofffehlstellen und damit eine höhere Ladungsträgerdichte als auch Funktionsschichten mit einem höheren Kristallisationsgrad und damit einhergehend einer höheren Beweglichkeit ausgebildet werden. Ein Großteil der vorliegenden Arbeit behandelt die Optimierung und Charakterisierung von ITO-Nanopartikel-Solen bzw. -Funktionsschichten. Neben den verwendeten Nanopartikeln, dem Dispergierungsprozess, der Beschichtungsart sowie der jeweiligen Beschichtungsparameter und der Nachbehandlung der Funktionsschichten, wurde erstmals in einer ausführlichen Parameterstudie die Sol-Zusammensetzung im Hinblick auf die Optimierung der infrarot-optischen und elektrischen Eigenschaften der applizierten Funktionsschichten untersucht. Dabei wurde insbesondere der Einfluss der verwendeten Stabilisatoren sowie der verwendeten Lösungsmittel auf die Schichteigenschaften charakterisiert. Im Rahmen dieser Arbeit wird dargelegt, dass die exakte Zusammensetzung der Nanopartikel-Sole einen große Rolle spielt und die Wahl des verwendeten Lösungsmittels im Sol einen größeren Einfluss auf den Gesamtemissionsgrad und die elektrischen Flächenwiderstände der applizierten Schichten hat als die Wahl des verwendeten Stabilisators. Allerdings wird auch gezeigt, dass keine pauschalen Aussagen darüber getroffen werden können, welcher Stabilisator oder welches Lösungsmittel in den Nanopartikel-Solen zu Funktionsschichten mit kleinen Gesamtemissionsgraden und elektrischen Flächenwiderständen führt. Stattdessen muss jede einzelne Kombination von verwendetem Stabilisator und Lösungsmittel empirisch getestet werden, da jede Kombination zu Funktionsschichten mit anderen Eigenschaften führt. Zudem konnte im Rahmen dieser Arbeit erstmals stabile AZO-Nanopartikel-Sole über verschiedene Rezepte hergestellt werden. Neben der Optimierung und Charakterisierung von ITO- und AZO- klassischen Sol-Gel- sowie Nanopartikel-Solen und -Funktionsschichten wurden auch die infrarot-optischen Eigenschaften dieser Schichten modelliert, um die optischen Konstanten sowie die Schichtdicken zu bestimmen. Darüber hinaus wurden auch kommerziell erhältliche, gesputterte ITO- und AZO-Funktionsschichten modelliert. Die Reflexionsgrade dieser drei Funktionsschicht-Typen wurden einerseits ausschließlich mit dem Drude-Modell anhand eines selbstgeschriebenen Programmes in Sage modelliert, und andererseits mit einem komplexeren Fit-Modell, welches in der kommerziellen Software SCOUT aus dem erweiterten Drude-Modell, einem Kim-Oszillator sowie dem OJL-Modell aufgebaut wurde. In diesem Fit-Modell werden auch die Einflüsse der Glas-Substrate auf die Reflexionsgrade der applizierten Funktionsschichten berücksichtigt und es können die optischen Konstanten sowie die Dicken der Schichten ermittelt werden. Darüber hinaus wurde im Rahmen dieser Arbeit ein Ellipsometer installiert und geeignete Fit-Modelle entwickelt, anhand derer die Ellipsometer-Messungen ausgewertet und die optischen Konstanten sowie Schichtdicken der präparierten Schichten bestimmt werden können. N2 - The aim of this thesis is on the one hand the synthesis of sol-gel functional layers on the basis of transparent conducting oxides (TCOs) and on the other hand a comprehensive infrared-optical and electrical characterization as well as modeling of these layers. Spectrally selective coatings have been prepared with the classical sol-gel route as well as with redispersed nanoparticle sols on glass and polycarbonate substrates and these coatings should have a reflectance in the infrared spectral range which is as high as possible and therefore a total emittance and an electrical sheet resistance which are as small as possible. For this purpose tin doped indium oxide (ITO) and aluminum doped zinc oxide (AZO) have been used as doped metal oxides. Within this thesis several parameters have been investigated in-depth which play a decisive role in the preparation of ITO and AZO low emissivity coatings, in order to prepare such coatings with optimized infrared-optical and electrical properties as well as visual transmittances. Besides the composition of the classical sol-gel ITO coating solutions, also the parameters of the coating as well as the heating processes have been characterized and optimized in the manufacture of classical sol-gel ITO and AZO functional layers. As a significant result the total emittance of classical sol-gel ITO functional layers could be reduced by 0.18 to 0.17 while the visual transmittance and electrical sheet resistances stay approximately the same, if just one-layered coatings are applied with a higher withdrawal speed with the dip coating technique instead of (optimized) multi-layered coatings. With a classical sol-gel ITO single coating, which has been produced with a withdrawal speed of 600 mm/min, the smallest total emittance of this work could be realized with 0.17. The total emittances and electrical sheet resistances of classical sol-gel AZO functional layers were reduced drastically in this work by using the optimized final heating process. The total emittance could be reduced by 0.34 to 0.50 and the electrical sheet resistance by 89 % to 65Ω/sq with a coating which consists of nine single layers. On the basis of Hall measurements it has been shown that coatings which were treated with the optimized heating process (which exhibits a higher temperature during the reducing treatment of the coatings) show a higher charge carrier density as well as a higher mobility than those coatings treated with the old heating process. With the optimized heating process the ninelayered coatings exhibit a charge carrier density of N = 4.3·1019 cm-3 which is approximately twice as high and a mobility of µ = 18.7 cm2/Vs which is about three times higher than the values of coatings which have been heated with the old process. This indicates that with the optimized heating process more oxygen vacancies and, associated therewith a higher charge carrier density as well as a higher crystallinity of the layer and thus a higher mobility are generated. One focus of the presented work lies on the optimization and characterization of ITO redispersed nanoparticle sols and functional layers respectively. In addition to the used nanoparticles, the dispersion process, the coating type with the respective coating parameters and post-treatments of the functional layers also a detailed parameter study has been done. This parameter study examined the composition of the nanoparticle sols with a view to the optimization of the infrared-optical and electrical properties of the applied coatings. The coating properties have been studied in particularly with regard to the influence of the used stabilizers and solvents respectively. In this work it will be shown, that the accurate composition of the nanoparticle sols plays a decisive role and the choice of the used solvents has a bigger impact on the coating properties than the choice of the used stabilizers. However, it will also be shown, that no general statements can be made which stabilizers or which solvents within the sols lead to coatings which have small total emittances and small electrical sheet resistances. Instead each combination of used stabilizer and used solvent has to be empirically tested since each combination leads to coatings with different properties. Furthermore stable AZO nanoparticle sols based on several formulas have been developed for the first time. Besides the optimization and characterization of ITO and AZO classical sol-gel as well as nanoparticle sols and functional layers, also the infrared-optical properties of these coatings have been modeled in order to determine the optical constants as well as the coating thicknesses. Furthermore also commercially available sputtered ITO and AZO coatings have been modeled. The reflectances of these three types of coatings have been modeled on the one hand by using only the Drude model within a self-written program in the software Sage. On the other hand these coatings have been modeled with more complex fitting models within the commercially available software called SCOUT. These more complex fitting models consist of the extended Drude model, a Kim oscillator and an OJL model and they also take the influence of the glass substrates on the reflectances of the applied coatings into account. By using these fitting models, the optical constants of the applied coatings and the coating thicknesses can be obtained. In addition an Ellipsometer has been installed as part of this work and suitable fitting models have been developed. These models can be used for analyzing the Ellipsometer measurements in order to determine the optical constants and the coating thicknesses of the coatings applied. KW - Transparent-leitendes Oxid KW - Sol-Gel-Verfahren KW - Beschichtung KW - Funktionswerkstoff KW - Sol-Gel-Synthese KW - ITO KW - AZO KW - redispergierte Nanopartikel-Sole KW - Drude-Modell KW - sol gel KW - redispersed nanoparticle sol KW - Drude model KW - Charakterisierung KW - Modellierung KW - Physikalische Schicht KW - Nanopartikel Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-112416 ER - TY - THES A1 - Winterfeldt, Carsten T1 - Generation and control of high-harmonic radiation T1 - Erzeugung und Kontrolle Hoher Harmonischer N2 - High-harmonic generation provides a powerful source of ultrashort coherent radiation in the XUV and soft-x-ray range, which also allows for the production of attosecond light pulses. Based on the unique properties of this new radiation it is now possible to perform time-resolved spectroscopy at high excitation energies, from which a wide field of seminal discoveries can be expected. Since the exploration and observation of the corresponding processes in turn are accompanied by the desire to control them, this work deals with new ways to manipulate and characterize the properties of these high-harmonic-based soft-x-ray pulses. After introductory remarks this work first presents a comprehensive overview over recent developments and achievements on the field of the control of high-harmonic radiation in order to classify the experimental results obtained in this work. These results include the control of high-harmonic radiation both by temporally shaping and by manipulating the spatial properties of the fundamental laser pulses. In addition, the influence of the conversion medium and of the setup geometry (gas jet, gas-filled hollow fiber) was investigated. Using adaptive temporal pulse shaping of the driving laser pulse by a deformable mirror, this work demonstrates the complete control over the XUV spectrum of high harmonics. Based on a closed-loop optimization setup incorporating an evolutionary algorithm, it is possible to generate arbitrarily shaped spectra of coherent soft-x-ray radiation in a gas-filled hollow fiber. Both the enhancement and suppression of narrowband high-harmonic emission in a selected wavelength region as well as the enhancement of coherent soft-x-ray radiation over a selectable extended range of harmonics (multiple harmonics) can be achieved. Since simulations that do not take into account spatial properties such as propagation effects inside a hollow fiber cannot reproduce the experimentally observed high contrast ratios between adjacent harmonics, a feedback-controlled adaptive two-dimensional spatial pulse shaper was set up to examine selective fiber mode excitation and the optimization of high-harmonic radiation in such a geometry. It is demonstrated that different fiber modes contribute to harmonic generation and make the high extent of control possible. These results resolve the long-standing issue about the controllability of high-harmonic generation in free-focusing geometries such as gas jets as compared to geometries where the laser is guided. Temporal pulse shaping alone is not sufficient. It was possible to extend the cutoff position of harmonics generated in a gas jet, however, selectivity cannot be achieved. The modifications of the high-harmonic spectrum have direct implications for the time structure of the harmonic radiation, including the possibility for temporal pulse shaping on an attosecond time scale. To this end, known methods for the temporal characterization of optical pulses and high-harmonic pulses (determination of the harmonic chirp on femtosecond and attosecond time scales) were introduced. The experimental progress in this work comprises the demonstration of different setups that are in principle suitable to determine the time structure of shaped harmonic pulses based on two-photon two-color ionization cross-correlation techniques. Photoelectron spectra of different noble gases generated by photoionization with high-harmonic radiation reproduce the spin-orbit splitting of the valence electrons and prove the satisfactory resolution of our electron time-of-flight spectrometer for the temporal characterization of high harmonics. Unfortunately no positive results for this part could be achieved so far, which can probably be attributed mainly to the lack of the focusability of the high harmonics and to the low available power of our laser system. However, we have shown that shaping the high-harmonic radiation in the spectral domain must result in modifications of the time structure on an attosecond time scale. Therefore this constitutes the first steps towards building an attosecond pulse shaper in the soft-x-ray domain. Together with the ultrashort time resolution, high harmonics open great possibilities in the field of time-resolved soft-x-ray spectroscopy, for example of inner-shell transitions. Tailored high-harmonic spectra as generated in this work and shaped attosecond pulses will represent a multifunctional toolbox for this kind of research. N2 - Die Erzeugung von Hohen Harmonischen stellt eine leistungsfähige Quelle ultrakurzer und kohärenter Strahlung im extremen Ultraviolett- und weichen Röntgenbereich dar, die auch die Erzeugung von Attosekundenlichtimpulsen erlaubt. Durch die einzigartigen Eigenschaften dieser neuen Strahlung ist es nun möglich, zeitaufgelöste Spektroskopie mit hohen Anregungsenergien durchzuführen, was eine Vielzahl bahnbrechender Entdeckungen erwarten lässt. Da die Erforschung und Beobachtung entsprechender Prozesse gekoppelt sind mit dem Wunsch, diese zu kontrollieren, beschäftigt sich die vorliegende Arbeit mit Wegen, die Eigenschaften dieser Röntgenpulse aus Hohen Harmonischen zu manipulieren und zu charakterisieren. Nach einleitenden Bemerkungen gibt diese Arbeit zunächst einen umfassenden Überblick über neueste Entwicklungen und Ergebnisse auf dem Gebiet der Kontrolle von Hohen Harmonischen, um die in dieser Arbeit erreichten experimentellen Ergebnisse einordnen zu können. Diese beinhalten die Kontrolle der Strahlung von Hohen Harmonischen sowohl durch die zeitliche Formung als auch durch die Manipulation der räumlichen Eigenschaften der fundamentalen Laserpulse. Untersucht wurde auch der Einfluss des Konversionsmediums und der Geometrie des Aufbaus (Gasstrahl, gasgefüllte Hohlfaser). Durch adaptive zeitliche Pulsformung der erzeugenden Laserpulse mit Hilfe eines deformierbaren Spiegels zeigt die vorliegende Arbeit die komplette Kontrolle über das XUV-Spektrum von Hohen Harmonischen. Basierend auf einem Optimierungsexperiment mit einer Rückkopplungsschleife und einem evolutionären Algorithmus ist es möglich, willkürlich geformte Spektren von kohärenter Strahlung im weichen Röntgenbereich in einer gasgefüllten Hohlfaser zu erzeugen. Sowohl die Steigerung und Unterdrückung von schmalbandiger Hohen-Harmonischen-Strahlung über einen ausgewählten Wellenlängenbereich als auch die Verstärkung von kohärenter weicher Röntgenstrahlung über einen wählbaren ausgedehnten Bereich von Harmonischen können erreicht werden. Da Simulationen ohne die Berücksichtigung von räumlichen Eigenschaften wie zum Beispiel Propagationseffekten in einer Hohlfaser die experimentell beobachteten hohen Kontrastverhältnisse zwischen benachbarten Harmonischen nicht reproduzieren konnten, wurde ein rückkopplungsgesteuerter zweidimensionaler räumlicher Pulsformer in Betrieb genommen, um die gezielte Anregung von Fasermoden und die Optimierung von Hohen Harmonischen in einer solchen Geometrie zu untersuchen. Es wird gezeigt, dass verschiedene Fasermoden zur Erzeugung von Harmonischen beitragen und erst das hohe Maß an Kontrolle ermöglichen. Diese Ergebnisse lösen eine lang bestehende Frage nach der Kontrollierbarkeit der Erzeugung von Hohen Harmonischen in Geometrien mit einem freien Fokus wie zum Beispiel in Gasstrahlen im Vergleich zu Geometrien, in denen der Laser geführt wird. Zeitliche Pulsformung allein reicht nicht aus. In einem Gasstrahl konnten zwar beispielsweise die höchsten erzeugten Harmonischen zu kürzeren Wellenlängen hin verschoben werden, eine Selektivität ist jedoch nicht möglich. Die Modifizierungen des Spektrums von Hohen Harmonischen haben direkte Auswirkungen auf die Zeitstruktur der Harmonischen-Strahlung, einschließlich der Möglichkeit für zeitliche Pulsformung im Attosekundenbereich. Dazu wurden bekannte Methoden zur zeitlichen Charakterisierung von optischen Pulsen und Hohen-Harmonischen-Pulsen vorgestellt. Der experimentelle Fortschritt in dieser Arbeit beinhaltet die Demonstration von verschiedenen Aufbauten, die im Prinzip geeignet sind, die Zeitstruktur von geformten Harmonischen-Pulsen mit Kreuzkorrelationsmethoden durch Zwei-Photonen-zwei-Farben-Ionisation zu bestimmen. Photoelektronenspektren verschiedener Edelgase, die durch Photoionisation mit der Hohen-Harmonischen-Strahlung erzeugt wurden, können die Spin-Bahn-Aufspaltung der Valenzelektronen reproduzieren und belegen die ausreichende Auflösung unseres Elektronen-Flugzeit-Spektrometers zur zeitlichen Charakterisierung von Hohen Harmonischen. Leider konnten bislang keine positiven Ergebnisse zu diesem Teil erzielt werden, was sich wohl hauptsächlich auf die fehlende Fokussierbarkeit der Harmonischen und die zu niedrige zur Verfügung stehende Leistung unseres Lasersystems zurückführen lässt. Wir haben jedoch gezeigt, dass die Formung der Hohen-Harmonischen-Strahlung im Spektralbereich Veränderungen der Zeitstruktur auf Attosekundenzeitskalen nach sich ziehen muss. Dies stellt daher erste Schritte in Richtung des Baus eines Attosekundenpulsformers im weichen Röntgenbereich dar. Zusammen mit der ultrakurzen Zeitauflösung eröffnen Hohe Harmonische daher viele Möglichkeiten auf dem Gebiet der zeitaufgelösten Spektroskopie im weichen Röntgenbereich, beispielsweise bei Innenschalen-Übergängen. Maßgeschneiderte Spektren von Hohen Harmonischen, wie sie in dieser Arbeit erzeugt werden konnten, und geformte Attosekundenpulse werden dabei vielseitige Werkzeuge darstellen. KW - Frequenzvervielfachung KW - Ultrakurzer Lichtimpuls KW - Attosekundenbereich KW - Adaptivregelung KW - Erzeugung Hoher Harmonischer KW - Wechselwirkung intensiver Laserpulse mit Materie KW - adaptive Kontrolle KW - Pulsformung KW - ultraschnelle Optik KW - high-harmonic generation KW - high-intensity laser-matter interaction KW - adaptive control KW - pulse shaping KW - ultrafast optics Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-20309 ER - TY - THES A1 - Winter, Patrick T1 - Neue Methoden zur Quantitativen Kardiovaskulären MR-Bildgebung T1 - New methods for quantitative cardiovascular magnetic resonance imaging N2 - Herzkreislauferkrankungen stellen die häufigsten Todesursachen in den Industrienationen dar. Die Entwicklung nichtinvasiver Bildgebungstechniken mit Hilfe der Magnetresonanz-Tomografie (MRT) ist daher von großer Bedeutung, um diese Erkrankungen frühzeitig zu erkennen und um die Entstehungsmechanismen zu erforschen. In den letzten Jahren erwiesen sich dabei genetisch modifzierte Mausmodelle als sehr wertvoll, da sich durch diese neue Bildgebungsmethoden entwickeln lassen und sich der Krankheitsverlauf im Zeitraffer beobachten lässt. Ein große Herausforderung der murinen MRT-Bildgebung sind die die hohen Herzraten und die schnelle Atmung. Diese erfordern eine Synchronisation der Messung mit dem Herzschlag und der Atmung des Tieres mit Hilfe von Herz- und Atemsignalen. Konventionelle Bildgebungstechniken verwenden zur Synchronisation mit dem Herzschlag EKG Sonden, diese sind jedoch insbesondere bei hohen Feldstärken (>3 T) sehr störanfällig. In dieser Arbeit wurden daher neue Bildgebungsmethoden entwickelt, die keine externen Herz- und Atemsonden benötigen, sondern das MRT-Signal selbst zur Bewegungssynychronisation verwenden. Mit Hilfe dieser Technik gelang die Entwicklung neuer Methoden zur Flussbildgebung und der 3D-Bildgebung, mit denen sich das arterielle System der Maus qualitativ und quantitativ erfassen lässt, sowie einer neuen Methode zur Quantisierung der longitudinalen Relaxationszeit T1 im murinen Herzen. Die in dieser Arbeit entwickelten Methoden ermöglichen robustere Messungen des Herzkreislaufsystems. Im letzten Kapitel konnte darüber hinaus gezeigt werden dass sich die entwickelten Bildgebungstechniken in der Maus auch auf die humane Bildgebung übertragen lassen. N2 - Cardiovascular diseases are one of the main causes of death in western countries. Hence, the development of non-invasive imaging techniques using Magnetic Resonance Imaging (MRI) is very important for early detection of these illnesses and for examination of the biological mechanisms. In the past years genetically modified mouse models have proven to be great assets, since they allow the development of new imaging techniques and to investigate the progress of cardiovascular diseases in time lapse. The main challenge of murine MRI is the high heart rate und the fast respiration. Hence, synchronization of the measurement with cardiac motion and breathing by using cardiac and respiration signals is required. Most imaging techniques use ECG leads for synchronization with the heartbeat, however, these probes are prone to disturbances at high magnetic field strengths (>3 T). In this work new imaging techniques were developed that do not use external cardiac and respiration signals but the MRI signal itself for motion synchronization. With these techniques new methods for flow quantification und 3D imaging could be developed for qualitative and quantitative measurements in the murine arteries. Furthermore, a new method for quantification of the longitudinal relaxation time T1 in the murine heart could be developed. The methods presented in this work enable more robust measurements of the cardiovascular system. In the last chapter it could be shown that the imaging techniques developed in the mouse can also be transferred to human MRI. KW - Kernspintomografie KW - Kardiovaskuläres System KW - Flussbildgebung KW - 3D-Bildgebung KW - Selbstnavigation KW - T1 KW - UTE KW - Maus KW - Aorta KW - Herzmuskel KW - Herzschlag Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-174023 ER - TY - THES A1 - Winnerlein, Martin T1 - Molecular Beam Epitaxy and Characterization of the Magnetic Topological Insulator (V,Bi,Sb)\(_2\)Te\(_3\) T1 - Molekularstrahlepitaxie und Charakterisierung des magnetischen topologischen Isolators (V,Bi,Sb)\(_2\)Te\(_3\) N2 - The subject of this thesis is the fabrication and characterization of magnetic topological insulator layers of (V,Bi,Sb)\(_2\)Te\(_3\) exhibiting the quantum anomalous Hall effect. A major task was the experimental realization of the quantum anomalous Hall effect, which is only observed in layers with very specific structural, electronic and magnetic properties. These properties and their influence on the quantum anomalous Hall effect are analyzed in detail. First, the optimal conditions for the growth of pure Bi\(_2\)Te\(_3\) and Sb\(_2\)Te\(_3\) crystal layers and the resulting structural quality are studied. The crystalline quality of Bi\(_2\)Te\(_3\) improves significantly at higher growth temperatures resulting in a small mosaicity-tilt and reduced twinning defects. The optimal growth temperature is determined as 260\(^{\circ}\)C, low enough to avoid desorption while maintaining a high crystalline quality. The crystalline quality of Sb\(_2\)Te\(_3\) is less dependent on the growth temperature. Temperatures below 230\(^{\circ}\)C are necessary to avoid significant material desorption, though. Especially for the nucleation on Si(111)-H, a low sticking coefficient is observed preventing the coalescence of islands into a homogeneous layer. The influence of the substrate type, miscut and annealing sequence on the growth of Bi\(_2\)Te\(_3\) layers is investigated. The alignment of the layer changes depending on the miscut angle and annealing sequence: Typically, layer planes align parallel to the Si(111) planes. This can enhance the twin suppression due to transfer of the stacking order from the substrate to the layer at step edges, but results in a step bunched layer morphology. For specific substrate preparations, however, the layer planes are observed to align parallel to the surface plane. This alignment avoids displacement at the step edges, which would cause anti-phase domains. This results in narrow Bragg peaks in XRD rocking curve scans due to long-range order in the absence of anti-phase domains. Furthermore, the use of rough Fe:InP(111):B substrates leads to a strong reduction of twinning defects and a significantly reduced mosaicity-twist due to the smaller lattice mismatch. Next, the magnetically doped mixed compound V\(_z\)(Bi\(_{1−x}\)Sb\(_x\))\(_{2−z}\)Te\(_3\) is studied in order to realize the quantum anomalous Hall effect. The addition of V and Bi to Sb\(_2\)Te\(_3\) leads to efficient nucleation on the Si(111)-H surface and a closed, homogeneous layer. Magneto-transport measurements of layers reveal a finite anomalous Hall resistivity significantly below the von Klitzing constant. The observation of the quantum anomalous Hall effect requires the complete suppression of parasitic bulklike conduction due to defect induced carriers. This can be achieved by optimizing the thickness, composition and growth conditions of the layers. The growth temperature is observed to strongly influence the structural quality. Elevated temperatures result in bigger islands, improved crystallographic orientation and reduced twinning. On the other hand, desorption of primarily Sb is observed, affecting the thickness, composition and reproducibility of the layers. At 190\(^{\circ}\)C, desorption is avoided enabling precise control of layer thickness and composition of the quaternary compound while maintaining a high structural quality. It is especially important to optimize the Bi/Sb ratio in the (V,Bi,Sb)\(_2\)Te\(_3\) layers, since by alloying n-type Bi\(_2\)Te\(_3\) and p-type Sb\(_2\)Te\(_3\) charge neutrality is achieved at a specific mixing ratio. This is necessary to shift the Fermi level into the magnetic exchange gap and fully suppress the bulk conduction. The Sb content x furthermore influences the in-plane lattice constant a significantly. This is utilized to accurately determine x even for thin films below 10 nm thickness required for the quantum anomalous Hall effect. Furthermore, x strongly influences the surface morphology: with increasing x the island size decreases and the RMS roughness increases by up to a factor of 4 between x = 0 and x = 1. A series of samples with x varied between 0.56-0.95 is grown, while carefully maintaining a constant thickness of 9 nm and a doping concentration of 2 at.% V. Magneto-transport measurements reveal the charge neutral point around x = 0.86 at 4.2 K. The maximum of the anomalous Hall resistivity of 0.44 h/e\(^2\) is observed at x = 0.77 close to charge neutrality. Reducing the measurement temperature to 50 mK significantly increases the anomalous Hall resistivity. Several samples in a narrow range of x between 0.76-0.79 show the quantum anomalous Hall effect with the Hall resistivity reaching the von Klitzing constant and a vanishing longitudinal resistivity. Having realized the quantum anomalous Hall effect as the first group in Europe, this breakthrough enabled us to study the electronic and magnetic properties of the samples in close collaborations with other groups. In collaboration with the Physikalisch-Technische Bundesanstalt high-precision measurements were conducted with detailed error analysis yielding a relative de- viation from the von Klitzing constant of (0.17 \(\pm\) 0.25) * 10\(^{−6}\). This is published as the smallest, most precise value at that time, proving the high quality of the provided samples. This result paves the way for the application of magnetic topological insulators as zero-field resistance standards. Non-local magneto-transport measurements were conducted at 15 mK in close collaboration with the transport group in EP3. The results prove that transport happens through chiral edge channels. The detailed analysis of small anomalies in transport measurements reveals instabilities in the magnetic phase even at 15 mK. Their time dependent nature indicates the presence of superparamagnetic contributions in the nominally ferromagnetic phase. Next, the influence of the capping layer and the substrate type on structural properties and the impact on the quantum anomalous Hall effect is investigated. To this end, a layer was grown on a semi-insulating Fe:InP(111)B substrate using the previously optimized growth conditions. The crystalline quality is improved significantly with the mosaicity twist reduced from 5.4\(^{\circ}\) to 1.0\(^{\circ}\). Furthermore, a layer without protective capping layer was grown on Si and studied after providing sufficient time for degradation. The uncapped layer on Si shows perfect quantization, while the layer on InP deviates by about 5%. This may be caused by the higher crystalline quality, but variations in e.g. Sb content cannot be ruled out as the cause. Overall, the quantum anomalous Hall effect seems robust against changes in substrate and capping layer with only little deviations. Furthermore, the dependence of the quantum anomalous Hall effect on the thickness of the layers is investigated. Between 5-8 nm thickness the material typically transitions from a 2D topological insulator with hybridized top and bottom surface states to a 3D topological insulator. A set of samples with 6 nm, 8 nm, and 9 nm thickness exhibits the quantum anomalous Hall effect, while 5 nm and 15 nm thick layers show significant bulk contributions. The analysis of the longitudinal and Hall conductivity during the reversal of magnetization reveals distinct differences between different thicknesses. The 6 nm thick layer shows scaling consistent with the integer quantum Hall effect, while the 9 nm thick layer shows scaling expected for the topological surface states of a 3D topological insulator. The unique scaling of the 9 nm thick layer is of particular interest as it may be a result of axion electrodynamics in a 3D topological insulator. Subsequently, the influence of V doping on the structural and magnetic properties of the host material is studied systematically. Similarly to Bi alloying, increased V doping seems to flatten the layer surface significantly. With increasing V content, Te bonding partners are observed to increase simultaneously in a 2:3 ratio as expected for V incorporation on group-V sites. The linear contraction of the in-plane and out-of-plane lattice constants with increasing V doping is quantitatively consistent with the incorporation of V\(^{3+}\) ions, possibly mixed with V\(^{4+}\) ions, at the group-V sites. This is consistent with SQUID measurements showing a magnetization of 1.3 \(\mu_B\) per V ion. Finally, magnetically doped topological insulator heterostructures are fabricated and studied in magneto-transport. Trilayer heterostructures with a non-magnetic (Bi,Sb)\(_2\)Te\(_3\) layer sandwiched between two magnetically doped layers are predicted to host the axion insulator state if the two magnetic layers are decoupled and in antiparallel configuration. Magneto-transport measurements of such a trilayer heterostructure with 7 nm undoped (Bi,Sb)\(_2\)Te\(_3\) between 2 nm thick layers doped with 1.5 at.% V exhibit a zero Hall plateau representing an insulating state. Similar results in the literature were interpreted as axion insulator state, but in the absence of a measurement showing the antiparallel magnetic orientation other explanations for the insulating state cannot be ruled out. Furthermore, heterostructures including a 2 nm thin, highly V doped layer region show an anomalous Hall effect of opposite sign compared to previous samples. A dependency on the thickness and position of the doped layer region is observed, which indicates that scattering at the interfaces causes contributions to the anomalous Hall effect of opposite sign compared to bulk scattering effects. Many interesting phenomena in quantum anomalous Hall insulators as well as axion insulators are still not unambiguously observed. This includes Majorana bound states in quantum anomalous Hall insulator/superconductor hybrid systems and the topological magneto-electric effect in axion insulators. The limited observation temperature of the quantum anomalous Hall effect of below 1 K could be increased in 3D topological insulator/magnetic insulator heterostructures which utilize the magnetic proximity effect. The main achievement of this thesis is the reproducible growth and characterization of (V,Bi,Sb)2Te3 layers exhibiting the quantum anomalous Hall effect. The detailed study of the structural requirements of the quantum anomalous Hall effect and the observation of the unique axionic scaling behavior in 3D magnetic topological insulator layers leads to a better understanding of the nature of this new quantum state. The high-precision measurements of the quantum anomalous Hall effect reporting the smallest deviation from the von Klitzing constant are an important step towards the realization of a zero-field quantum resistance standard. N2 - Das Thema dieser Arbeit ist die Herstellung und Charakterisierung von Schichten des magnetischen topologischen Isolators (V,Bi,Sb)\(_2\)Te\(_3\), die den Quanten anomalen Hall-Effekt zeigen. Die Hauptaufgabe war die experimentelle Realisierung des Quanten anomalen Hall-Effekts, welcher nur in Schichten mit bestimmten strukturellen, elektronischen und magnetischen Eigenschaften beobachtet wird. Diese Eigenschaften wurden ermittelt und ihr Einfluss genau analysiert. Als Erstes wurden die optimalen Bedingungen für das Wachstum von reinen Bi\(_2\)Te\(_3\) und Sb\(_2\)Te\(_3\) Kristallschichten und die resultierende strukturelle Qualität untersucht. Die kristalline Qualität von Bi\(_2\)Te\(_3\) verbessert sich signifikant bei hohen Wachstumstemperaturen, welche die Neigung der Domänen verringern und Zwillingsdefekte reduzieren. Als optimale Wachstumstemperatur wurde 260\(^{\circ}\)C ermittelt, ausreichend niedrig um Desorption zu vermeiden während eine hohe Kristallqualität erhalten bleibt. Die Wachstumstemperatur von Sb\(_2\)Te\(_3\) hat einen geringeren Einfluss auf die Kristallqualität. Temperaturen unter 230\(^{\circ}\)C sind allerdings nötig um erhebliche Desorption zu vermeiden. Ein geringer Haftkoeffizient wurde besonders bei der Nukleation auf der Si(111)-H Oberfläche beobachtet und verhindert das Zusammenwachsen von Inseln zu einer homogenen Schicht. Der Einfluss des Substrattyps, der Fehlorientierung der Oberfläche und der Ausheizsequenz auf das Wachstum von Bi\(_2\)Te\(_3\) Schichten wurde untersucht. Die Ausrichtung der Schicht ändert sich je nach Winkel der Fehlorientierung und der Ausheilsequenz: Typischerweise orientieren sich die Ebenen der Schicht parallel zu den Si(111) Ebenen, was aufgrund des Transfers der Stapelfolge vom Substrat zur Schicht an den Stufenkanten die Unterdrückung von Zwillingsdefekte verbessert. Andererseits führt diese Orientierung zu Anti-Phasen-Domänen durch die Verschiebung an den Stufenkanten und zu einer gestuften Oberflächenmorphologie. Für bestimmte Substratpräparationen richtet sich die Schicht jedoch parallel zur Oberfläche aus. Diese Orientierung verhindert Verschiebungen an Stufenkanten und damit Anti-Phasen-Domänen. Dies führt aufgrund der langreichweitigen Ordnung zu sehr schmalen Bragg-Reflexen in XRD rocking curve Diffraktogrammen. Weiterhin führen raue Fe:InP(111):B Substrate zu einer starken Unterdrückung von Zwillingsdefekten und aufgrund der besseren Gitteranpassung zu einer deutlich verringerten Verdrehung der Domänen. Als Nächstes wurde das magnetisch dotierte V\(_z\)(Bi\(_{1−x}\)Sb\(_x\))\(_{2−z}\)Te\(_3\) untersucht mit dem Ziel den Quanten anomalen Hall-Effekt zu realisieren. Die Zugabe von V und Bi zu Sb\(_2\)Te\(_3\) führt zu einer effizienten Nukleation auf der Si(111)-H Oberfläche und einer geschlossenen, homogenen Schicht. Magnetotransport Messungen der Schichten ergeben einen messbaren anomalen Hall-Widerstand deutlich unter der von-Klitzing-Konstanten. Die Beobachtung des Quanten anomalen Hall-Effekts setzt eine vollständige Unterdrückung der defekt-induzierten, parasitären Leitfähigkeit im Inneren der Schicht voraus. Dies kann durch die Optimierung der Dicke, Zusammensetzung und Wachstumsbedingungen der Schicht erreicht werden. Beobachtungen zeigen, dass die Wachstumstemperatur die strukturelle Qualität stark beeinflusst. Erhöhte Temperaturen erzielen größere Inseln, eine verbesserte kristalline Orientierung und weniger Zwillingsdefekte. Andererseits wird Desorption von überwiegend Sb beobachtet, was sich auf die Dicke, Zusammensetzung und Reproduzierbarkeit der Schichten auswirkt. Bei 190\(^{\circ}\)C kann Desorption vermieden werden, was eine präzise Kontrolle über Schichtdicke und Zusammensetzung des quaternären Verbunds ermöglicht, während eine hohe strukturelle Qualität erhalten bleibt. Es ist besonders wichtig das Bi/Sb Verhältnis zu optimieren, da durch das Legieren des n-Typ Bi\(_2\)Te\(_3\) mit dem p-Typ Sb\(_2\)Te\(_3\) bei einem bestimmten Verhältnis Ladungsneutralität erzielt wird. Dies ist nötig um die Leitung im Inneren der Schicht vollständig zu unterdrücken und die Fermikante in die magnetische Austauschlücke zu schieben. Der Sb Gehalt x beeinflusst außerdem die Gitterkonstante a in der Ebene deutlich, im Gegensatz zur Gitterkonstante c in Wachstumsrichtung. Mit Hilfe dieses Zusammenhangs kann x selbst in dünnen Schichten unter 10 nm Dicke, wie sie für den Quantum anomalen Hall-Effekt benötigt werden, genau bestimmt werden. Der Sb Gehalt x beeinflusst weiterhin die Oberflächenmorphologie deutlich: mit steigenden x verringert sich die Inselgröße und die RMS Rauigkeit wächst um bis zu einem Faktor 4 zwischen x = 0 und x = 1. Eine Probenserie mit x zwischen 0,56−0,95 wurde hergestellt, wobei darauf geachtet wurde eine konstante Dicke von 9 nm und eine Dotierkonzentration von 2 at.% V beizubehalten. Magnetotransport Messungen bei 4,2K zeigen Ladungsneutra- lität bei x = 0,86. Der maximale anomale Hall-Widerstand von 0,44 h/e\(^2\) wird bei x = 0,77 nahe der Ladungsneutralität beobachtet. Wird die Messtemperatur auf 50 mK reduziert, steigt der anomale Hall-Widerstand signifikant an. Mehrere Proben mit x in einem schmalen Bereich von 0,76−0,79 zeigen den Quanten anomalen Hall-Effekt mit einem Hall-Widerstand, der die von-Klitzing-Konstante erreicht, und verschwindendem longitudinalen Widerstand. Die Realisierung des Quantum anomalen Hall-Effekts als erste Gruppe in Europa ermöglichte es uns die elektrischen und magnetischen Eigenschaften der Proben in Zusammenarbeit mit anderen Gruppen zu untersuchen. In Kollaboration mit der Physikalisch-Technische Bundesanstalt wurden Hochpräzisionsmessungen mit detaillierter Fehleranalyse durchgeführt und eine relative Abweichung von der von-Klitzing-Konstante von (0,17\(\pm\)0,25)*10\(^{−6}\) erzielt. Dieser Wert wurde als kleinster und genauester Wert publiziert, was die hohe Qualität der zur Verfügung gestellten Proben zeigt. Dieses Ergebnis ebnet den Weg für die Anwendung von magnetischen topologischen Isolatoren als Widerstand Standards ohne Magnetfeld. In enger Zusammenarbeit mit der Transport Gruppe in der EP3 wurden nichtlokale Magnetotransport Messungen bei 15mK durchgeführt. Das Ergebnis beweist, dass Transport durch chirale Randkanäle erfolgt. Die detaillierte Analyse kleiner Anomalien in Transport Messungen offenbart Instabilitäten in der magnetischen Phase selbst bei 15 mK. Der zeitabhängige Charakter dieser Anomalien weist auf superparamagnetische Anteile in der nominell ferromagnetischen Phase hin. Als nächstes wurde der Einfluss der Deckschicht und des Substrattyps auf die strukturellen Eigenschaften und die Auswirkungen auf den Quanten anomalen Hall-Effekt untersucht. Dazu wurde eine Schicht auf halbisolierendem Fe:InP(111)B Substrat unter den zuvor optimierten Wachstumsbedingungen gewachsen. Dies führt zu einer deutlich erhöhten kristallinen Qualität mit einem verringerten Verdrehungswinkel von 5,4\(^{\circ}\) auf 1,0\(^{\circ}\). Weiterhin wurde eine Schicht ohne schützende Deckschicht auf Si gewachsen und, nachdem ausreichend Zeit für mögliche Degradation vergangen war, gemessen. Die Schicht auf Si ohne Deckschicht zeigt perfekte Quantisierung, während die Schicht auf InP eine Abweichung von etwa 5% aufweist. Ursache könnte die höhere kristalline Qualität sein, Variationen in z.B. Sb Gehalt könnten jedoch auch eine Rolle spielen. Insgesamt scheint der Quanten anomale Hall-Effekt robust gegenüber Änderungen des Substrats und der Deckschicht zu sein. Des Weiteren wurde die Abhängigkeit des Quanten anomalen Hall-Effekts von der Schichtdicke untersucht. Zwischen 5−8 nm Dicke wechselt das Material typischerweise von einem 2D topologischen Isolator mit hybridisierten oberen und unteren Oberflächenzustand zu einem 3D topologischen Isolator. Eine Probenreihe mit 6 nm, 8 nm und 9 nm Schichtdicke zeigt den Quanten anomalen Hall- Effekt, während 5 nm und 15 nm dicke Schichten deutliche Beiträge aus dem Volumen haben. Die Analyse der longitudinalen- und Hall-Leitfähigkeit während der Umkehrung der Magnetisierung offenbart eindeutige Unterschiede. Die 6 nm dicke Schicht zeigt ein Skalierungsverhalten konsistent mit dem ganzzahligen Quanten- Hall-Effekt, die 9 nm dicke Schicht dagegen zeigt das erwartete Skalierungsverhalten für die topologischen Oberflächenzustände eines 3D topologischen Isolators. Das besondere Skalierungsverhalten der 9 nm dicken Schicht ist von besonderem Interesse, da es der axionischen Elektrodynamik in einem 3D topologischen Isolator entspringen könnte. Anschließend wird der Einfluss von V Dotierung auf die strukturellen und magnetischen Eigenschaften der Schichten systematisch untersucht. Ähnlich wie das Legieren mit Bi, scheint V Dotieren die Oberfläche deutlich zu glätten. Mit steigenden V Gehalt erhöht sich die Zahl der Te Bindungspartner simultan im 2:3 Verhältnis, wie erwartet für den Einbau von V auf Gruppe-V Plätzen. Die lineare Kontraktion der Gitterkonstanten in der Ebene und senkrecht dazu mit steigender V Dotierung ist quantitativ konsistent mit dem Einbau von V\(^{3+}\) Ionen, möglicherweise gemischt mit V\(^{4+}\) Ionen, auf Gruppe-V Plätzen. Dies ist konsistent mit SQUID Messungen die eine Magnetisierung von 1,3 \(\mu_B\) pro V Ion zeigen. Schließlich werden magnetisch dotierte topologische Isolator Heterostrukturen hergestellt und in Magnetotransport Messungen charakterisiert. Der Axion-Isolator Zustand wurde in dreischichtigen Heterostrukturen mit einer nichtmagnetischen (Bi,Sb)\(_2\)Te\(_3\) Lage zwischen zwei magnetischen Schichten vorhergesagt, falls die beiden magnetischen Lagen entkoppelt sind und in antiparalleler Ausrichtung vorliegen. Magnetotransport Messungen solcher dreischichtigen Heterostrukturen mit 7 nm undotiertem (Bi,Sb)\(_2\)Te\(_3\) zwischen jeweils 2 nm dicken dotierten Schichten mit 1,5 at.% V zeigen ein Null Hall-Plateau, das einen isolierenden Zustand repräsentiert. Ähnliche Ergebnisse in der Literatur wurden als Axion-Isolator Zustand interpretiert, jedoch können andere Erklärungen ohne eine direkten Messung der antiparallelen magnetischen Orientierung nicht ausgeschlossen werden. Weiterhin zeigen Heterostrukturen mit einer 2 nm dünnen, hoch V dotierten Schicht einen anomalen Hall-Effekt mit entgegengesetzten Vorzeichen im Vergleich zu vorhergehenden Proben. Die Abhängigkeit von der Dicke und Position dieser Schicht könnte darauf hindeuten, dass Streuprozesse an den Grenzflächen einen Beitrag zum anomalen Hall-Effekt entgegengesetzt zu den Volumenstreuprozessen verursachen. Viele interessante Phänomene in Quanten anomalen Hall Isolatoren sowie Axion- Isolatoren sind noch nicht eindeutig beobachtet worden. Dies schließt gebundene Majorana-Zustände in Quanten anomalen Hall Isolator/Supraleiter Hybridsystemen und den topologischen magneto-elektrischen Effekt in Axion-Isolatoren ein. Die limitierte Beobachtungstemperatur des Quanten anomalen Hall-Effekts von unter 1 K könnte in Heterostrukturen aus 3D topologischen Isolator und magnetischen Isolator Schichten welche den magnetischen Proximity-Effekt nutzen erhöht werden. Das wichtigste Ergebnis dieser Arbeit ist das reproduzierbare Wachstum und die Charakterisierung von (V,Bi,Sb)\(_2\)Te\(_3\) Schichten die den Quanten anomalen Hall-Effekt zeigen. Die detaillierte Untersuchung der strukturellen Voraussetzungen und die Beobachtung des besonderen axionischen Skalierungsverhaltens in 3D magnetischen Isolatorschichten führt zu einem besseren Verständnis dieses neuen Quantenzustands. Die Hochpräzisionsmessungen des Quanten anomalen Hall-Effekts mit der geringsten Abweichung von der von-Klitzing-Konstanten sind ein wichtiger Schritt zur Realisierung eines Widerstand-Standards basierend auf Quantisierung ohne magnetischem Feld. KW - Bismutverbindungen KW - Topologischer Isolator KW - Molekularstrahlepitaxie KW - Quanten anomalen Hall-Effekt KW - Quantum anomalous Hall effect Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-211666 ER - TY - THES A1 - Wilhelm, Thomas T1 - Konzeption und Evaluation eines Kinematik/Dynamik-Lehrgangs zur Veränderung von Schülervorstellungen mit Hilfe dynamisch ikonischer Repräsentationen und graphischer Modellbildung T1 - Conception and evaluation of a kinematics/dynamics course to change students' conceptions with the aid of dynamic-iconic representations and graphic modelling N2 - Auch nach dem herkömmlichen Mechanikunterricht in der Oberstufe verfügen viele Schüler nicht über angemessene physikalische Vorstellungen über die verwendeten physikalischen Begriffe und deren Zusammenhänge. Einführend wurden in dieser Arbeit allgemeine Aspekte zu Schülervorstellungen (Kapitel 2.1) sowie konkrete Schülervorstellungen zur Mechanik (Kapitel 2.2) und relevante Lehrervorstellungen (Kapitel 2.3) dargelegt. Ein Ziel dieser Arbeit war, ein Gesamtkonzept für einen veränderten Kinematik- und Dynamikunterricht ein- und zweidimensionaler Bewegungen in der Jahrgangsstufe 11 des Gymnasiums zu entwickeln, das möglichst vielen Schülern hilft, möglichst viele Fehlvorstellungen zur Mechanik aufzuarbeiten. Dazu wurden u.a. computergestützte Experimente und die Visualisierung der physikalischen Größen mit dynamisch ikonischen Repräsentationen (siehe Kapitel 3.2) eingesetzt, was neue Elementarisierungen und neue Unterrichtsstrategien ermöglichte (siehe Kapitel 8.2 oder Kapitel 5). Um gute Chancen zu haben, dass dieses Konzept den Schulalltag erreicht, wurde es lehrplankonform zum bayerischen Lehrplan konzipiert. Eine erste Zielsetzung der summativen Evaluation war festzustellen, inwieweit das gesamte Unterrichtskonzept von verschiedenen Lehrern durchführbar ist und wie diese es einschätzen (siehe Kapitel 8.4 oder Kapitel 6.3). Ein wichtiges Ziel war dann, mit Hilfe von Tests festzustellen, inwieweit es Veränderungen in den Schülervorstellungen gab (Vor-/Nachtest-Design) und diese Veränderungen mit konventionell unterrichteten Klassen zu vergleichen (Trainings-/Kontrollgruppen-Design) (konventionelle Klassen: Kapitel 8.1; Vergleich: Kapitel 8.5; Kapitel 6.4 + 6.5). Dazu wurden hauptsächlich bereits vorliegende paper-pencil-Tests verwendet, da eine Testneuentwicklung im Rahmen der Arbeit nicht möglich gewesen wäre. Da diese Tests verschiedene Schwächen haben, wurden mehrere verschiedene Tests gleichzeitig eingesetzt, die sich gegenseitig ergänzen. Die graphische Modellbildung in Verbindung mit Animationen ist ein fakultativer Teil dieses Unterrichtskonzeptes. Hierzu wurde zusätzlich eine eigene Interventionsstudie durchgeführt (siehe Kapitel 8.3 und Kapitel 4). Ergebnisse: Dynamisch ikonische Repräsentationen können dem Lehrer neue unterrichtliche Möglichkeiten geben und somit dem Schüler helfen, physikalische Konzepte angemessener zu verstehen. Die Einführung kinematischer Größen anhand zweidimensionaler Bewegungen, die nur mit ikonischen Repräsentationen in Form von Vektorpfeilen sinnvoll ist (geeignete Elementarisierung), führt zu einem physikalischeren Verständnis des Beschleunigungsbegriffes und vermeidet Fehlvorstellungen durch eine ungeeignete Reduktion auf den Spezialfall eindimensionaler Bewegungen. Mehr Schüler konzeptualisieren Beschleunigung wie in der Physik als gerichtete Größe anstelle einer Größe, die die Änderung des Geschwindigkeitsbetrages angibt und allenfalls tangentiale Richtung haben kann. Auch in der Dynamik sind dadurch hilfreiche Darstellungen und so sinnvolle Veränderungen des Unterrichts möglich. Um wesentliche Strukturen aufzuzeigen, werden komplexere Versuche mit mehreren Kräften und Reibung eingesetzt, was erst durch eine rechnerunterstützte Aufbereitung mit dynamisch ikonischen Repräsentationen ermöglicht wird. Diese Darstellungen ermöglichen auch eine aktive Auseinandersetzung der Schüler mit den Themen, indem von ihnen häufig Vorhersagen gefordert werden (geeignete Unterrichtsstrategie). Graphische Modellbildung als weiterer Einsatz bildlicher Darstellungen kann ebenso eine weitere Verständnishilfe sein. Schüler, die nach dem vorgelegten Unterrichtskonzept unterrichtet wurden, zeigten mehr Verständnis für den newtonschen Kraftbegriff. Da die entwickelten Ideen tatsächlich im Unterricht ankamen und dort Veränderungen bewirkten, kann von einer effektiven Lehrerfortbildung mit Transferwirkung gesprochen werden. N2 - Even after the traditional mechanics instruction in the senior classes, many students do not have any adequate physical conceptions of the physical terms and definitions used, as well as of their coherencies. This study therefore commences with a presentation of general aspects of students’ conceptions (chapter 2.1) as well as precise students' conceptions on mechanics (chapter 2.2) and relevant teachers’ conceptions (chapter 2.3). An objective of this study was to develop an overall concept for modified kinematics and dynamics instruction of motions in one and two dimensions in grade 11 of grammar school, aiming at helping as many students as possible to clear as many misconceptions on mechanics as possible. In order to achieve this goal, computer-aided experiments and the visualisation of physical quantities with dynamic-iconic representations (see chapter 3.2) were used, among other things, thus enabling new elementarizations as well as new teaching strategies (see chapter 9.2 or chapter 5). In order to have good chances that this concept reaches the school everyday life, it was conceived curriculum-conformal to the Bavarian curriculum. The first goal of the summative evaluation was to determine to what extent the entire teaching concept can be implemented by different teachers, and how they assess said concept (see chapter 9.4 or chapter 6.3). Subsequently, an important objective was to ascertain, by means of tests, to which extent the students’ conceptions had changed (pre-/post-testing design), and to compare these changes with conventionally taught classes (treatment-/control-group design) (conventional classes: chapter 9.1; comparison: chapter 9.5; chapters 6.4 + 6.5). For that purpose, already existing paper-pencil-tests were mainly used, as a new development of tests would not have been possible in the course of the study. These tests have various shortcomings, so several tests were used at the same time, complementing each other. Graphic modelling in combination with animations is part of this teaching concept. Additionally, an own intervention study was carried out in this context (see chapter 9.3 and chapter 4). Results: Dynamic-iconic representations can provide teachers with new teaching possibilities and thus help students to adequately understand physical concepts. An introduction of kinematic quantities with the aid of two-dimensional motions, which makes only sense with iconic representations in the form of vector arrows (suitable elementarization), leads to a more physical understanding of the acceleration concept and avoids misconceptions due to an inept reduction to the special case of motions in one dimension. More students conceptualize acceleration – like in physics – as a directed quantity instead of a quantity indicating the change of the magnitude of velocity and having at best tangential direction. This renders possible helpful representations for and thus reasonable changes of dynamics instruction as well: In order to illustrate essential structures, more complex experiments with several forces and friction are used, which is only feasible because of a computer-aided preparation with dynamic-iconic representations. These representations also allow for the students to actively deal with the subject by often asking them to make predictions (suitable teaching strategy). Graphic modelling as another application of iconic representations can also further understanding. Students who were instructed pursuant to the teaching concept on hand showed a greater understanding of Newton's concept of force. As the developed ideas were in fact well received in class and caused changes there, it can be called an effective further teacher training with a transfer effect. KW - Physikunterricht KW - Modellierung KW - Physikdidaktik KW - Kinematik KW - Dynamik KW - Modellbildung KW - Schülervorstellungen KW - physics education KW - kinematics KW - dynamics KW - modelling KW - students' conceptions Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-39554 N1 - Das Buch mit CD-ROM kann unter der ISBN 978-3-8325-1046-6 auch online oder über den Buchhandel beim Logos-Verlag Berlin bestellt werden. Siehe auch http://www.logos-verlag.de/cgi-bin/buch?isbn=1046 ER - TY - THES A1 - Wilfert, Stefan T1 - Rastertunnelmikroskopische und -spektroskopische Untersuchung von Supraleitern und topologischen Supraleitern T1 - Scanning Tunneling Microscopy and Spectroscopy Study of Superconductors and Topological Superconductors N2 - Quantencomputer können manche Probleme deutlich effizienter lösen als klassische Rechner. Bisherige Umsetzungen leiden jedoch an einer zu geringen Dekohärenzzeit, weshalb die Lebenszeit der Quantenzustände einen limitierenden Faktor darstellt. Topologisch geschützte Anregungen, wie Majorana-Fermionen, könnten hingegen dieses Hindernis überwinden. Diese lassen sich beispielsweise in topologischen Supraleitern realisieren. Bis zum jetzigen Zeitpunkt existieren nur wenige Materialien, die dieses Phänomen aufweisen. Daher ist das Verständnis der elektronischen Eigenschaften für solche Verbindungen von großer Bedeutung. In dieser Dissertation wird die Koexistenz von Supraleitung an der Probenoberfläche und topologischem Oberflächenzustand (engl. topological surface state, TSS) auf potentiellen topologischen Supraleitern überprüft. Diese beiden Bedingungen sind essentiell zur Ausbildung von topologischer Supraleitung in zeitumkehrgeschützten Systemen. Hierzu wird mittels Landaulevelspektroskopie und Quasiteilcheninterferenz das Vorhandensein des TSS am Ferminiveau auf Tl$_{x}$Bi$_{2}$Te$_{3}$ und Nb$_{x}$Bi$_{2}$Se$_{3}$ verifiziert, die mittels Transportmessungen als supraleitend identifiziert wurden. Anschließend folgen hochaufgelöste Spektroskopien an der Fermienergie, um die supraleitenden Eigenschaften zu analysieren. Zur Interpretation der analysierten Eigenschaften wird zu Beginn der Ni-haltige Schwere-Fermion-Supraleiter TlNi$_{2}$Se$_{2}$ untersucht, der eine vergleichbare Übergangstemperatur besitzt. Anhand diesem werden die gängigen Messmethoden der Rastertunnelmikroskopie und -spektroskopie für supraleitende Proben vorgestellt und die Leistungsfähigkeit der Messapparatur demonstriert. Im Einklang mit der Literatur zeigt sich ein $s$-Wellencharakter des Paarungsmechanismus sowie die Formation eines für Typ~II-Supraleiter typischen Abrikosov-Gitters in schwachen externen Magnetfeldern. Im folgenden Teil werden die potentiellen topologischen Supraleiter Tl$_{x}$Bi$_{2}$Te$_{3}$ und Nb$_{x}$Bi$_{2}$Se$_{3}$ begutachtet, für die eindeutig ein TSS bestätigt wird. Allerdings weisen beide Materialien keine Oberflächensupraleitung auf, was vermutlich durch eine Entkopplung der Oberfläche vom Volumen durch Bandverbiegung zu erklären ist. Unbeabsichtigte Kollisionen der Spitze mit der Probe führen jedoch zu supraleitenden Spitzen, die wesentlich erhöhte Werte für die kritische Temperatur und das kritische Feld zeigen. Der letzte Abschnitt widmet sich dem supraleitenden Substrat Nb(110), für den der Reinigungsprozess erläutert wird. Hierbei sind kurze Heizschritte bis nahe des Schmelzpunktes nötig, um die bei Umgebungsbedingungen entstehende Sauerstoffrekonstruktion effektiv zu entfernen. Des Weiteren werden die elektronischen Eigenschaften untersucht, die eine Oberflächenresonanz zum Vorschein bringen. Hochaufgelöste Messungen lassen eine durch die BCS-Theorie gut repräsentierte Struktur der supraleitenden Energielücke erkennen. Magnetfeldabhängige Experimente offenbaren zudem eine mit der Kristallstruktur vereinbare Anisotropie des Paarungspotentials. Mit diesen Erkenntnissen kann Nb(110) zukünftig als Ausgang für das Wachstum von topologischen Supraleitern herangezogen werden. N2 - Quantum computers are able to solve certain problems a lot more efficiently than classical processors. However, current realizations lack of a suitable decoherence \mbox{time} resulting in insufficient lifetimes of quantum states as the major limiting factor. Topological protected excitations such as Majorana fermions living in topological superconductors show great potential to overcome this obstacle. Since there exists only a small amount of materials with these characteristics the understanding of the electronic properties of such compounds is very important. In this thesis, the coexistence of a topological surface state (TSS) and superconductivity at the sample's surface of potential topological superconductors is studied. These two conditions must be fulfilled for the formation of topological superconductivity in time reversal invariant systems. For this purpose, Landau level spectroscopy and quasiparticle interference are carried out on Tl$_{x}$Bi$_{2}$Te$_{3}$ und Nb$_{x}$Bi$_{2}$Se$_{3}$ to verify the TSS at the Fermi energy. Transport measurements showed superconductivity in the bulk for both materials. High resolution spectroscopy experiments at the Fermi energy are performed to analyze the superconductivity. For interpretation of these data, we study the Ni-based heavy fermion superconductor TlNi$_{2}$Se$_{2}$ with a comparable transition temperature to the above mentioned compounds. In this context, the common measuring methods of scanning tunneling microscopy and spectroscopy for superconducting samples are presented and the performance capability of our experimental setup is demonstrated. In consistence with the literature, we find an $s$-wave pairing mechanism and the formation of an Abrikosov lattice typical for type~II superconductors in small external fields. The following part of this work is the investigation of the potential topological superconductors Tl$_{x}$Bi$_{2}$Te$_{3}$ und Nb$_{x}$Bi$_{2}$Se$_{3}$ that clearly confirm the presence of a TSS on both materials. No surface superconductivity can be discovered on both compounds presumably caused due to band bending thus leading to a decoupling of the surface from the bulk. However, unintentional collisions between tip and sample lead to the formation of superconducting tips with considerably higher values for the critical temperature and field as compared to the bulk results. In the last paragraph, the superconducting substrate Nb(110) is characterized. Firstly, a cleaning procedure including flashing the sample to temperatures close to the melting point is necessary to remove the oxygen reconstruction that has been formed at ambient conditions. A surface resonance is found upon analyzing the electronic properties. High resolution spectroscopy measurements lead to a superconducting gap in good agreement with the BCS theory. Additionally, magnetic field dependent experiments show an anisotropy of the pair potential accordingly to the crystal symmetry. These findings confirm that Nb(110) shows great potential as a superconducting substrate for growing topological superconductors in the future. KW - Supraleitung KW - Topologischer Isolator KW - Rastertunnelmikroskop KW - Supraleiter 2. Art KW - Topologische Supraleitung KW - Rastertunnelspektroskopie Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-180597 ER - TY - THES A1 - Wießner, Michael T1 - Isolierte Moleküle und delokalisierte Zustände: Einblick in die elektronische Struktur organischer Adsorbate mittels winkelaufgelöster Photoemission T1 - Isolated molecules and delocalised states: Insight into the electronic structure of organic adsorbates by angle-resolved photoemission N2 - Die vorliegende Arbeit demonstriert an Hand von verschiedenen Modellsystemen wie detailliert sich die grundlegenden Eigenschaften molekularer Adsorbate mit der winkelaufgelösten Photoemission erkunden lassen. Die von Peter Puschnig et al. vorgestellte Verknüpfung zwischen Photoemissionsintensität und den Molekülorbitalen im Grundzustand mittels einer Fouriertransformation war dabei entscheidend, um die verschiedenen physikalischen Effekte einordnen und verstehen zu können. Während für Coronen oder HBC die Orbitale im Grundzustand sehr gut zum Experiment passen, lassen sich für PTCDA und NTCDA einige Abweichungen von der DFT-Rechnung auf Basis der (semi-)lokalen GGA- oder LDA-Funktionale erkennen, die sich bei Messungen mit s-Polarisation hervorheben lassen. Diese können auf den Einfluss des Endzustandes in der Photoemission zurückgeführt werden. Im Rahmen der Dysonorbitale lassen sich die dafür verantwortlichen Relaxationseffekte zwischen dem N-Elektronensystem des Moleküls im Grundzustand und dem (N-1)-Elektronensystem des zurückbleibenden Kations explizit beschreiben. Die Berechnung des Photoemissionssignals mittels Fouriertransformation des Grundzustandes kann darüber hinaus weitere physikalische Effekte nicht korrekt berücksichtigen. Erste Anzeichen hierfür konnten am PTCDA-HOMO bei einer Photonenenergie von 27 eV und s-Polarisation detektiert werden. Darüber hinaus kann die Näherung des Photoelektronenendzustands als ebene Welle den beobachteten zirkularen Dichroismus am HOMO und LUMO von PTCDA nicht erklären. Erst in der Erweiterung durch eine Partialwellenzerlegung des Photoelektronenendzustands tritt ein dichroisches Signal in der theoretischen Beschreibung auf. Für das delokalisierte pi-Elektronensystem von PTCDA ist aber selbst diese Verfeinerung noch nicht ausreichend, um das Experiment korrekt beschreiben und weitere Eigenschaften vorhersagen zu können. Qualitativ lassen sich die Veränderungen im CDAD bei der Transformation um 90° für HOMO und LUMO mit einem gruppentheoretischen Ansatz verstehen. Damit ist es möglich, den molekularen Zuständen ihre irreduzible Darstellung zuzuweisen, worüber sich für PTCDA die Verteilung der quantenmechanischen Phase rekonstruieren lässt. Dies ist deshalb äußerst bemerkenswert, da üblicherweise in physikalischen Experimenten nur die Intensität und keine Informationen über die Phase messbar sind. Damit können die Photoemissionsmessungen im k||-Raum vollständig in den Realraum transformiert werden, wodurch die laterale Ortsinformation über die höchsten besetzen Molekülorbitale von PTCDA zugänglich wird. Neben der Bestimmung der molekularen Orbitale, deren Struktur von der Anordnung der Atome im Molekül dominiert wird, enthält die winkelaufgelöste Photoemission Informationen über die Adsorbat-Substrat-Wechselwirkung. Für hoch geordnete Monolagen ist es möglich, die verschiedenen Verbreiterungsmechanismen zu trennen und zu analysieren. Bei den untersuchten Systemen sind die Verbreiterungen aufgrund von unterschiedlichen Adsorptionsplätzen oder Probeninhomogenitäten ebenso wie die experimentelle Auflösung der 2D-Analysatoren vernachlässigbar gegenüber Lebensdauereffekten und evtl. Verbreiterung aufgrund von Dispersionseffekten. Bereits bei den äußerst schwach wechselwirkenden Systemen Coronen auf Ag(111) und Au(111) unterscheiden sich die beiden Systeme in ihrer Lorentzverbreiterung beim HOMO. In erster Näherung lässt sich dies auf eine Lebensdauer des entstandenen Photolochs zurückführen, welches je nach Stärke der Substratkopplung unterschiedlich schnell mit Substratelektronen aufgefüllt werden kann. Die Lorentzbreite als Indikator für die Wechselwirkung bzw. Hybridisierungsstärke zeigt für die Systeme mit Ladungstransfer vom Substrat in das Molekül eine sehr viel größere Verbreiterung. Zum Beispiel beträgt die Lorentzbreite des LUMO für NTCDA/Ag(110) FWHM=427 meV, und somit eine mehr als fünfmal so große Verbreiterung als für das HOMO von Coronen/Au(111). Diese starke Verbreiterung geht im Fall von NTCDA/Ag(110) wie auch bei den untersuchten Systemen NTCDA/Cu(100) und PTCDA/Ag(110) einher mit einem Ladungstransfer vom Substrat ins Molekül, sowie mit der Ausbildung eines zusätzlichen charakteristischen Signals in der Winkelverteilung des LUMO, dem Hybridisierungszustand bei kx,y=0Å-1. Die Intensität dieses Zustands korreliert bei den Systemen NTCDA auf Cu(100) bzw. auf Ag(110) jeweils mit der Lorentzbreite des LUMO-Zustands. Die Hybridisierung zwischen Molekül und Substrat hat noch weitere Auswirkungen auf die beobachtbaren physikalischen Eigenschaften. So führt die starke Hybridisierung mit dem Substrat wiederum dazu, dass sich die intermolekulare Dispersion für die Elektronen im LUMO-Zustand deutlich verstärkt. Der direkte Überlapp der Wellenfunktionen ist im System PTCDA/Ag(110) laut DFT-Rechnungen relativ klein und führt lediglich zu einer Bandbreite von 60 meV. Durch die Hybridisierung mit den delokalisierten Substratbändern erhöht sich der Grad der Delokalisierung im LUMO-Zustand, d.h. die Bandbreite steigt auf 230 meV, wie das Experiment bestätigt. Im Gegensatz zu früheren STM/STS-basierten Messungen [Temirov2006] kann mit der Kombination aus DFT-Rechnung und ARPES-Experiment eindeutig nachgewiesen werden, dass das Substrat im Fall von PTCDA/Ag(110) die Bandbreite verstärken kann, sodass sich die effektive Masse der Lochladungsträger von meff=3,9me auf meff=1,1me reduziert. Im Blick auf die eingangs gestellte Frage, ob sich molekulare Adsorbate eher wie isolierte Moleküle oder als periodische Festkörper beschreiben lassen, kommt diese Arbeit auf ein differenziertes Ergebnis. In den Impulsverteilungen, die sich aus der Form der molekularen Wellenfunktionen ableiten lassen, spiegelt sich eindeutig der isolierte molekulare Charakter wieder. Dagegen zeigt sich in der Energiedispersion E(k||) ein delokalisierter, blochartiger Charakter, und es konnte demonstriert werden, dass es zu einem Vermischen von Metall- und Molekülwellenfunktionen kommt. Molekulare Adsorbate sind also beides, isolierte Moleküle und zweidimensionale Kristalle mit delokalisierten Zuständen. N2 - This work demonstrates the versatility of angular resolved photoemission (ARPES) in extracting fundamental properties of molecular condensates. With the technique proposed by Peter Puschnig et al., ARPES intensities of aromatic molecules can be linked to the absolute square of the fourier transformed molecular orbital. This allows experimentally identifying individual orbitals and understanding different physical mechanisms at the interface between an organic layer and a metal. This technique shows a clear agreement between theoretical intensity distributions, as e.g. derived from density functional theory (DFT), and the measurements on systems like coronene and HBC. Opposite to that, deviations occur on PTCDA and NTCDA for both local and semilocal density functionals, is s-polarized light is used. Additional measurements with different polarisation directions show, that relaxation effects in the final state lead to a mixing of the N-particle initial state with the N-1-particle final state. This phenomenon can be described theoretically within the framework of Dyson orbitals, in an approximate way already by introducing self-interaction corrected density functionals. Additional deviations from the simple approximation of the photoelectron by a plane wave can be made visible with circular polarised light. For the PTCDA HOMO and LUMO, circular dichroism appears in the angular distribution of the photoemission intensity, an effect that is by definition not included in the plane wave approximation. A refined approximation given by the partial wave expansion of the final state shows a distinct dichroism of both the HOMO and LUMO. But apparently this approximation is not able to describe the detailed circular dichroism angular distribution. In the future, this might be possible by applying the Independent Atomic Center (IAC) approximation including multiple intramolecular scattering. The origin of the dichroic signal can be elucidated by measurements with different incidence directions and applying group theory. The changes in the dichroism signal of the HOMO and LUMO upon rotation by 90° is different indicating on different irreducible representations for both states. This paves the way to reconstruct the intramolecular phase distribution for the rather simple PTCDA HOMO and LUMO. Access to this distribution is usually hindered by the measurement process itself due to the absolute square in the evaluation of the photoemission matrix elements. And finally with the knowledge of the intensity and the phase a transformation of the HOMO and LUMO to real space is possible. Next to the measurement of individual molecular orbitals, ARPES contains signatures from the molecule substrate interaction. For a unique identification of the several interaction mechanisms a commensurate lattice of molecules is indispensable. Otherwise different adsorption sites would sum up to a broad photoemission signal, both in energy and momentum direction. For the commensurate systems of coronene or HBC on the Ag(111) and Au(111) surfaces, this prerequisite is fulfilled. The analysis of the peak shape shows different Lorentzian broadenings of the adiabatic vibronic transition of the HOMO. This width can be approximately correlated to the lifetime of the photo hole. Therefor a stronger molecule metal interaction leads to a faster decay of the photo hole on the molecule and consequently to broader lorentzian line width. For example the lorentzian width of the hybridized NTCDA on Ag(110) is of FWHM=427 meV and therewith five times larger than the rather weakly interacting coronene on Au(111). The strong interaction for NTCDA on Ag(110) but also for the investigated systems NTCDA on Cu(100) and PTCDA on Ag(110) goes along with charge transfer from the substrate to the molecule, i.e. the LUMO gets filled for the molecules in the first layer. Moreover a hybridization occurs between the metal and the molecule resulting in an additional contribution to the LUMO in the momentum distribution at kx,y=0Å-1. In the direct comparison of the NTCDA/Ag(110) and NTCDA/Cu(100) adsorption systems, this intensity of this contribution can be linked to the interaction strength deduced from the lorentzian width of the respective LUMO. The hybridization has even more consequences on this interface system. The observable intermolecular band dispersion gets drastically enhanced due to the increased interaction strength mediated by the molecule substrate hybridization. The direct overlap of the PTCDA LUMO wave function is according to the DFT calculation rather small leading to a band width of only 60 meV. Opposite to that, the experiment as well as the calculation for a PTCDA layer adsorbed on a silver slab show a band width of 230 meV, which can only be explained by the additional adsorbate. And opposite to previous STM/STS measurements [Temirov2006] the observed substrate mediated band width enhancement is clearly observed for a molecular state, whose effective mass is reduced by this mechanism from meff=3,9me to meff=1,1me. In conclusion, this work demonstrates how the properties of electrons in molecules and at interfaces to a metal can be detected and characterised by the photoemission technique. If these systems are rather characterized by localized molecular orbitals than by delocalized bloch waves, depends on the individual properties. On the one hand the momentum dependency of the photoemission intensity of indivdual orbitals match nearly perfect the calculation on isolated molecules. On the other hand, the momentum dependent binding energies E(k||) show a bloch-like character, whose band width is amplified by the substrate interaction. This means, the molecular adsorbate is both, molecules and a 2D-crystal with delocalized states. KW - Organisches Molekül KW - Adsorbat KW - ARPES KW - Organische Moleküle KW - Hochgeordnete Monolagen KW - Molekülphysik KW - Festkörperphysik KW - Perylendianhydrid Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-95265 ER - TY - THES A1 - Wiest, Wolfram T1 - Entwicklung einer Apparatur zur In-situ-Ermüdungsprüfung von Zahnimplantaten mittels Synchrotron Micro-CT T1 - Development of an apparatus for in-situ fatigue testing of dental implants using synchrotron micro-CT N2 - Die vorliegende Arbeit beschäftigt sich mit der volumenbildgebenden Untersuchung von mechanischen Ermüdungsprozessen in Titan-Zahnimplantaten. Im Vordergrund steht die Entwicklung einer neuen Messmethode der In-situ-Mikrotomografie am Synchrotron. Zahnimplantate werden beim Gebrauch mechanisch wiederholt belastet (Wechsellast). Nach vielen zyklischen Belastungen können aufgrund von mikroplastische Verformungen Ermüdungsschäden auftreten. Diese können im Extremfall zum Versagen und Verlust eines Implantats führen. Die Computertomographie ist eine sehr geeignete zerstörungsfrei Prüfmethode, um Zahnimplantate zu untersuchen. Diese Arbeit erweitert die bisherige CT-Methode insofern, dass In-situ-Beobachtungen bei mechanischer Belastung möglich sind. Die in dieser Arbeit untersuchten Zahnimplantate weisen an der Implantat-Abutment-Grenzfläche bei eintretender Ermüdung einen Mikrospalt auf. Dieser wird als Indikator für einsetzende Fatigue- Prozesse benutzt. Der in der Synchrotron CT verfügbare Inlinephasenkontrast ermöglicht eine verbesserte Bestimmung der Mikrospaltgröße. Da die schnellen Bewegungen der Ermüdungsprüfung mittels Standard-CT-Verfahren schwer zu erfassen sind, war die stroboskopische Aufnahmemethode das zielführende Messverfahren, um in-situ-Prüfung zu ermöglichen. Die 4 kommerziellen Zahnimplantattypen werden neben der In-situ-Fatigue Prüfung auch mittels klassischer Ermüdungsprüfung untersucht und mit der Neuen Messmethode verglichen. Die hier entwickelte In-situ-Fatigue-Prüfstation kann Proben bis zu 345 N tomographisch untersuchen. Neben den experimentellen Untersuchungen wird eine statische FEM-Betrachtung durchgeführt und mit experimentellen Messdaten verglichen. Zuletzt wird mit der entwickelten Messtation Knochenrisse in der Implantat Umgebung untersucht. N2 - The present work deals with the volume imaging investigation of mechanical fatigue processes in titanium dental implants. The focus is on the development of a new measurement method of in-situ microtomography at the synchrotron. Dental implants are exposed to repeated mechanical loads. After many cyclic loads, fatigue damage can occur due to microplastic deformation. These can lead to failure and loss of an implant. Computed tomography is a very suitable non-destructive testing method to examine dental implants. This work extended the existing method to the point where in situ CT observations under mechanical loading are achievable. The dental implants investigated in this work exhibit a microgap at the implant-abutment interface when fatigue occurs. This is used as an indicator for the occurrence of fatigue processes. The inline phase contrast available in synchrotron CT can be used to determine the size of the microgap. Since the fast motions of fatigue testing are difficult to capture using standard CT techniques, the stroboscopic imaging method was the used measurement technique, to enable in-situ testing. In addition to in-situ fatigue testing, the 4 commercial dental implant types are also examined and compared with each other by means of classical fatigue testing. The developed in-situ fatigue test station can tomographically investigate specimens up to 345 N. In addition to the experimental investigations, a static FEM analysis is performed and compared with experimental measurement data. Finally, the developed measuring station is used to investigate bone cracks in the implant environment. KW - Mikrocomputertomographie KW - Fatigue KW - In situ KW - Zahnimplantat KW - In situ KW - fatigue KW - microtomography KW - dental implant Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-257702 ER - TY - THES A1 - Wiener, Matthias T1 - Synthese und Charakterisierung Sol-Gel-basierter Kohlenstoff-Materialien für die Hochtemperatur-Wärmedämmung T1 - Synthesis and Characterisation Sol-Gel-based Carbon-Materials for High Temperature Thermal Insulation N2 - Gegenstand der vorliegenden Arbeit ist die Synthese, Charakterisierung und Optimierung von Kohlenstoff-Aerogelen (C-Aerogele) für den Einsatz als Hochtemperaturwärmedämmung (> 1000°C). C-Aerogele sind offenporöse monolithische Festkörper, die durch Pyrolyse von organischen Aerogelen entstehen. Die Synthese dieser organischen Vorstufen erfolgt über das Sol-Gel-Verfahren. Zur Charakterisierung der Morphologie wurde die innere Struktur der Aerogele mittels Raster- und Transmissionselektronenmikroskopie, Röntgendiffraktometrie (XRD), Raman-Spektroskopie, Stickstoffsorption und Röntgenkleinwinkelstreuung (SAXS) untersucht. Die thermischen Eigenschaften der Aerogele wurden mit Hilfe von Laser-Flash Messungen, dynamischer Differenzkalorimetrie (DSC), thermographischen und infrarot-optischen (IR) Messungen quantifiziert. Die innere Struktur von Aerogelen besteht aus einem dreidimensionalen Gerüst von Primärpartikeln, die während der Sol-Gel Synthese ohne jede Ordnung aneinander wachsen. Die zwischen den Partikeln befindlichen Hohlräume bilden die Poren. Die mittlere Partikel- und Porengröße eines Aerogels kann durch die Konzentration der Ausgangslösung und der Katalysatorkonzentration einerseits und durch die Synthesetemperatur und –dauer andererseits eingestellt werden. Der Bereich der mittleren Partikel- und Porengröße, der in dieser Arbeit synthetisierten Aerogele, erstreckt sich von einigen 10 Nanometern bis zu einigen Mikrometern. Die Dichten der Proben wurden im Bereich von 225 kg/m3 bis 635 kg/m3 variiert. Die Auswirkungen der Pyrolysetemperatur auf die Struktur und die thermischen Eigenschaften der C-Aerogele wurden anhand einer Probenserie erstmalig systematisch untersucht. Die Proben wurden dazu bei Temperaturen von 800°C bis 2500°C pyrolysiert bzw. temperaturbehandelt (geglüht). Um die einzelnen Beiträge zur Wärmeleitfähigkeit trennen und minimieren zu können, wurden die synthetisierten Aerogele thermisch mit mehreren Meßmethoden unter unterschiedlichen Bedingungen charakterisiert. Temperaturabhängige Messungen der spezifischen Wärmekapazität cp im Bereich von 32°C bis 1500°C ergaben für C-Aerogele verglichen mit den Literaturdaten von Graphit einen ähnlichen Verlauf. Allerdings steigt cp etwas schneller mit der Temperatur an, was auf eine „weichere“ Struktur hindeutet. Die maximale Abweichung beträgt etwa 11%. Messungen an einer Serie morphologisch identischer Aerogelproben, die im Temperaturbereich zwischen 800°C und 2500°C pyrolysiert bzw. geglüht wurden, ergeben eine Zunahme der Festkörperwärmeleitfähigkeit mit der Behandlungstemperatur um etwa einen Faktor 8. Stickstoffsorptions-, XRD-, Raman- und SAXS-Messungen an diesen Proben zeigen, dass dieser Effekt wesentlich durch das Wachstum der graphitischen Bereiche (Mikrokristallite) innerhalb der Primärpartikel des Aerogels bestimmt wird. Berechnungen auf Basis von Messungen der Temperaturleitfähigkeit weisen außerdem auch auf Veränderungen der Mikrokristallite hin. Gasdruckabhängige Messungen der Wärmeleitfähigkeit und der Vergleich zwischen Messungen unter Vakuum und unter Normaldruck an verschiedenen Aerogelmorphologien liefern Aussagen über den Gasanteil der Wärmeleitfähigkeit. Dabei zeigt sich, dass sich der Gasanteil der Wärmeleitfähigkeit in den Poren des Aerogels verglichen mit dem freien Gas durch die geeignete mittlere Porengröße erwartungsgemäß erheblich verringern lässt. Diese Ergebnisse stimmen in Rahmen der Messunsicherheit mit der Theorie überein. Durch infrarot-optische Messungen an C-Aerogelen konnte der Extinktionskoeffizient bestimmt und daraus der entsprechende Beitrag der Wärmestrahlung zur Wärmeleitfähigkeit berechnet werden. Temperaturabhängige Messungen der thermischen Diffusivität erlaubten mit der zur Verfügung stehenden Laser-Flash Apparatur die Bestimmung der Wärmeleitfähigkeit bis zu Temperaturen von 1500°C. Die Temperaturabhängigkeit der Wärmeleitfähigkeit der C-Aerogele zeigt eine Charakteristik, die mit den separat gemessenen bzw. berechneten Beiträgen zur Wärmeleitfähigkeit und der Theorie im Rahmen der Messunsicherheit gut übereinstimmen. Auf der Basis der gewonnenen Messdaten ist es möglich, die Wärmeleitfähigkeit von Aerogelen für Anwendungen über die maximale Messtemperatur von 1500°C durch Extrapolation vorherzusagen. Die niedrigste Wärmeleitfähigkeit der im Rahmen dieser Arbeit synthetisierten C-Aerogele beträgt danach etwa 0,17 W/(m•K) bei 2500°C unter Argonatmosphäre. Kommerziell erhältliche Hochtemperatur-Wärmedämmstoffe, wie z. B. Kohlefaserfilze oder Kohlenstoffschäume weisen Wärmeleitfähigkeiten im Bereich von etwa 0,7 bis 0,9 W/(m•K) bei einer Temperatur von 2000°C auf. Die Messungen zeigen, dass die vergleichsweise niedrigen Wärmeleitfähigkeiten von C-Aerogelen bei hohen Temperaturen durch die Unterdrückung des Gas- und Strahlungsbeitrags der Wärmeleitfähigkeit bedingt sind. N2 - The scope of the present work is the synthesis, the characterisation and the optimisation of carbon (c-) aerogels as high temperature insulation (> 1000°C). Carbon aerogels are open porous monolithic solids which are produced by pyrolysis of organic aerogels. These organic precursors are synthesized via the sol-gel route. For the structural characterisation of the aerogels the samples were investigated by scanning electron microscopy, transmission electron microscopy, X-ray diffraction (XRD), Raman spectroscopy, nitrogen sorption measurements and small angle X-ray scattering (SAXS). The thermal properties of the aerogels were quantified by laser flash measurements, differential scanning calorimetry (DSC), thermographic and infrared optical measurements. The inner structure of the aerogels consists of a three dimensional skeleton of primary particles which grow during the sol-gel synthesis and are connected to each other without any orientation. The voids between the particles are the pores. The mean particle and pore size of the aerogel can be tailored specifically via the concentration of the catalyst and the degree of dilution of the educt solution on the one hand and the synthesis time and -temperature on the other hand. The range of the mean particle and pore sizes of the aerogels synthesized within this work extends from some tens of nanometers to some microns. The density of the samples was varied in the range from 225 kg/m3 to 635 kg/m3. The impact of pyrolysis and annealing temperature on the morphology and the thermal properties of carbon aerogels was investigated for the first time systematically on one series of samples. For that purpose the samples were pyrolysed and annealed in the range of 800 to 2500°C. To separate and minimize the individual contributions, the thermal conductivity of the synthesized c-aerogels were thermally characterized by different measuring methods under various conditions. The measurements of the specific heat in the range of 32 to 1500°C yield values similar to the literature data of graphite; however slightly systematic higher values of up to 11% were observed as expected for “softer” solids with high interfacial surface areas. Measurements of a series of carbon aerogels with identical morphology, however different annealing temperatures, show an increase of the solid thermal conductivity with increasing annealing temperature of up to a factor of about 8 for temperatures between 800°C and 2500°C. Nitrogen sorption-, XRD-, Raman-, and SAXS-measurements reveal that this effect is dominated by the growth of graphitic domains (microcrystallites) within the primary particles of the aerogel. In addition calculations based on measurements of the thermal diffusivity indicate changes of the microcrystallites. Measurements of the thermal conductivity of aerogels with different morphologies as a function of gas pressure and the comparison of the data taken under vacuum and normal pressure yield informations about the gaseous contribution to the thermal conductivity. As expected, the gaseous thermal conductivity within the pores of the aerogel can be reduced compared to the free gas when the pore size is in the range of the mean free path of the gas molecules or smaller. The results agree with the theory within the measuremental uncertainties. Infrared optical measurements provide the extinction coefficient of carbon aerogels, from which the radiative contribution to the thermal conductivity could be determined. The laser flash equipment available at the ZAE Bayern allows measurements of the thermal diffusivity up to 1500°C from which the thermal conductivity can be determined. The thermal conductivity of carbon aerogels as a function of temperature is well described by a superposition of the single contributions determined separately and the theoretical predictions within the uncertainties. Based on the experimental data it is possible to extrapolate the thermal conductivity of carbon aerogels for applications beyond the maximum temperature investigated (1500°C). Thus the lowest thermal conductivity of the carbon aerogels synthesized in the scope of this work is about 0,17 W/(m•K) at 2500°C in argon atmosphere. This value is about a factor 4 lower than for the best commercially available insulation material. KW - Hochtemperatur KW - Aerogel KW - Hochtemperatur KW - Kohlenstoff KW - Wärmeisolierstoff KW - Sol-Gel-Verfahren KW - Bayerisches Zentrum für Angewandte Energieforschung / Abteilung Wärmedämmung und Wärmetransport KW - thermal insulation KW - carbon KW - aerogel KW - high temperature KW - nano Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-44245 ER - TY - THES A1 - Wiedenmann, Jonas T1 - Induced topological superconductivity in HgTe based nanostructures T1 - Induzierte topologische Supraleitung in HgTe basierten Nanostrukturen N2 - This thesis describes the studies of topological superconductivity, which is predicted to emerge when pair correlations are induced into the surface states of 2D and 3D topolog- ical insulators (TIs). In this regard, experiments have been designed to investigate the theoretical ideas first pioneered by Fu and Kane that in such system Majorana bound states occur at vortices or edges of the system [Phys. Rev. Lett. 100, 096407 (2008), Phys. Rev. B 79, 161408 (2009)]. These states are of great interest as they constitute a new quasiparticle which is its own antiparticle and can be used as building blocks for fault tolerant topological quantum computing. After an introduction in chapter 1, chapter 2 of the thesis lays the foundation for the understanding of the field of topology in the context of condensed matter physics with a focus on topological band insulators and topological superconductors. Starting from a Chern insulator, the concepts of topological band theory and the bulk boundary corre- spondence are explained. It is then shown that the low energy Hamiltonian of mercury telluride (HgTe) quantum wells of an appropriate thickness can be written as two time reversal symmetric copies of a Chern insulator. This leads to the quantum spin Hall effect. In such a system, spin-polarized one dimensional conducting states form at the edges of the material, while the bulk is insulating. This concept is extended to 3D topological insulators with conducting 2D surface states. As a preliminary step to treating topological superconductivity, a short review of the microscopic theory of superconductivity, i.e. the theory of Bardeen, Cooper, and Shrieffer (BCS theory) is presented. The presence of Majorana end modes in a one dimensional superconducting chain is explained using the Kitaev model. Finally, topological band insulators and conventional superconductivity are combined to effectively engineer p-wave superconductivity. One way to investigate these states is by measuring the periodicity of the phase of the Josephson supercurrent in a topological Josephson junction. The signature is a 4π-periodicity compared to the 2π-periodicity in conventional Josephson junctions. The proof of the presence of this effect in HgTe based Josephson junction is the main goal of this thesis and is discussed in chapters 3 to 6. Chapter 3 describes in detail the transport of a 3D topological insulator based weak link under radio-frequency radiation. The chapter starts with a review of the state of research of (i) strained HgTe as 3D topological insulator and (ii) the progress of induc- ing superconducting correlations into the topological surface states and the theoretical predictions of 3D TI based Josephson junctions. Josephson junctions based on strained HgTe are successfully fabricated. Before studying the ac driven Josephson junctions, the dc transport of the devices is analysed. The critical current as a function of temperature is measured and it is possible to determine the induced superconducting gap. Under rf illumination Shapiro steps form in the current voltage characteristic. A missing first step at low frequencies and low powers is found in our devices. This is a signature of a 4π-periodic supercurrent. By studying the device in a wide parameter range - as a 147148 SUMMARY function of frequency, power, device geometry and magnetic field - it is shown that the results are in agreement with the presence of a single gapless Andreev doublet and several conventional modes. Chapter 4 gives results of the numerical modelling of the I −V dynamics in a Josephson junction where both a 2π- and a 4π-periodic supercurrents are present. This is done in the framework of an equivalent circuit representation, namely the resistively shunted Josephson junction model (RSJ-model). The numerical modelling is in agreement with the experimental results in chapter 3. First, the missing of odd Shapiro steps can be understood by a small 4π-periodic supercurrent contribution and a large number of modes which have a conventional 2π-periodicity. Second, the missing of odd Shapiro steps occurs at low frequency and low rf power. Third, it is shown that stochastic processes like Landau Zener tunnelling are most probably not responsible for the 4π contribution. In a next step the periodicity of Josephson junctions based on quantum spin Hall insulators using are investigated in chapter 5. A fabrication process of Josephson junctions based on inverted HgTe quantum wells was successfully developed. In order to achieve a good proximity effect the barrier material was removed and the superconductor deposited without exposing the structure to air. In a next step a gate electrode was fabricated which allows the chemical potential of the quantum well to be tuned. The measurement of the diffraction pattern of the critical current Ic due to a magnetic field applied perpendicular to the sample plane was conducted. In the vicinity to the expected quantum spin Hall phase, the pattern resembles that of a superconducting quantum interference device (SQUID). This shows that the current flows predominantly on the edges of the mesa. This observation is taken as a proof of the presence of edge currents. By irradiating the sample with rf, missing odd Shapiro steps up to step index n = 9 have been observed. This evidences the presence of a 4π-periodic contribution to the supercurrent. The experiment is repeated using a weak link based on a non-inverted HgTe quantum well. This material is expected to be a normal band insulator without helical edge channels. In this device, all the expected Shapiro steps are observed even at low frequencies and over the whole gate voltage range. This shows that the observed phenomena are directly connected to the topological band structure. Both features, namely the missing of odd Shapiro steps and the SQUID like diffraction pattern, appear strongest towards the quantum spin Hall regime, and thus provide evidence for induced topological superconductivity in the helical edge states. A more direct way to probe the periodicity of the Josephson supercurrent than using Shapiro steps is the measurement of the emitted radiation of a weak link. This experiment is presented in chapter 6. A conventional Josephson junction converts a dc bias V to an ac current with a characteristic Josephson frequency fJ = eV /h. In a topological Josephson junction a frequency at half the Josephson frequency fJ /2 is expected. A new measurement setup was developed in order to measure the emitted spectrum of a single Josephson junction. With this setup the spectrum of a HgTe quantum well based Josephson junction was measured and the emission at half the Josephson frequency fJ /2 was detected. In addition, fJ emission is also detected depending on the gate voltage and detection frequency. The spectrum is again dominated by half the Josephson emission at low voltages while the conventional emission is determines the spectrum at high voltages. A non-inverted quantum well shows only conventional emission over the whole gateSUMMARY 149 voltage and frequency range. The linewidth of the detected frequencies gives a measure on the lifetime of the bound states: From there, a coherence time of 0.3–4ns for the fJ /2 line has been deduced. This is generally shorter than for the fJ line (3–4ns). The last part of the thesis, chapter 7, reports on the induced superconducting state in a strained HgTe layer investigated by point-contact Andreev reflection spectroscopy. For the experiment, a HgTe mesa was fabricated with a small constriction. The diameter of the orifice was chosen to be smaller than the mean free path estimated from magne- totransport measurements. Thus one gets a ballistic point-contact which allows energy resolved spectroscopy. One part of the mesa is covered with a superconductor which induces superconducting correlations into the surface states of the topological insulator. This experiment therefore probes a single superconductor normal interface. In contrast to the Josephson junctions studied previously, the geometry allows the acquisition of energy resolved information of the induced superconducting state through the measurement of the differential conductance dI/dV as a function of applied dc bias for various gate voltages, temperatures and magnetic fields. An induced superconducting order parame- ter of about 70µeV was extracted but also signatures of the niobium gap at the expected value around Δ Nb ≈ 1.1meV have been found. Simulations using the theory developed by Blonder, Tinkham and Klapwijk and an extended model taking the topological surface states into account were used to fit the data. The simulations are in agreement with a small barrier at the topological insulator-induced topological superconductor interface and a high barrier at the Nb to topological insulator interface. To understand the full con- ductance curve as a function of applied voltage, a non-equilibrium driven transformation is suggested. The induced superconductivity is suppressed at a certain bias value due to local electron population. In accordance with this suppression, the relevant scattering regions change spatially as a function of applied bias. To conclude, it is emphasized that the experiments conducted in this thesis found clear signatures of induced topological superconductivity in HgTe based quantum well and bulk devices and opens up the avenue to many experiments. It would be interesting to apply the developed concepts to other topological matter-superconductor hybrid systems. The direct spectroscopy and manipulation of the Andreev bound states using circuit quantum electrodynamic techniques should be the next steps for HgTe based samples. This was already achieved in superconducting atomic break junctions by the group in Saclay [Science 2015, 349, 1199-1202 (2015)]. Another possible development would be the on-chip detection of the emitted spectrum as a function of the phase φ through the junction. In this connection, the topological junction needs to be shunted by a parallel ancillary junction. Such a setup would allow the current phase relation I(φ) directly and the lifetime of the bound states to be measured directly. By coupling this system to a spectrometer, which can be another Josephson junction, the energy dependence of the Andreev bound states E(φ) could be obtained. The experiments on the Andreev reflection spectroscopy described in this thesis could easily be extended to two dimensional topological insulators and to more complex geometries, like a phase bias loop or a tunable barrier at the point-contact. This work might also be useful for answering the question how and why Majorana bound states can be localized in quantum spin Hall systems. N2 - Die vorliegende Dissertation befasst sich mit der experimentellen Untersuchung von topologischer Supraleitung, die durch die Kombination von konventionellen Supraleitern mit 2D- und 3D- topologischen Isolatoren (TI) entsteht. Diesbezüglich wurden Experi- mente durchgeführt, die auf zwei bahnbrechenden Arbeiten von Fu und Kane [Phys. Rev. Lett. 100, 096407 (2008), Phys. Rev. B 79, 161408 (2009)] aufbauen. Diesen zufolge wird in supraleitenden topologischen Isolatoren ein neuartiges Quasiteilchen, ein sogenanntes Majorana-Fermion, vorhergesagt. Das große Interesse an diesem Teilchen beruht auf des- sen besonderen Eigenschaften. Es sind Fermionen mit halbzahligen Spin, jedoch besitzen sie keine Ladung und es ist gleichzeitig sein eigenes Antiteilchen. Darüber hinaus besitzt das Teilchen im Vergleich zu konventionellen Fermionen eine andere Austauschstatistik und zählt daher zu den sogenannten nicht-abelschen Anyonen. Aufgrund dieser Eigen- schaften wurde vorhergesagt, dass sie für weniger fehleranfällige Quantenbits als Bauteile für einen Quantencomputer verwendet werden können. Nach einer Einleitung in Kapitel 1 folgt in Kapitel 2 eine Einführung in das Konzept von Topologie in der Festkörperphysik. Der Schwerpunkt liegt dabei auf zwei Materialklassen, topologischen Isolatoren und topologische Supraleiter. Zunächst wird ein Zweibandmo- dell, der Chern-Isolator, beschrieben, um das Konzept von topologischen Isolatoren und die Entstehung von Oberflächenzuständen darzulegen. Es ist möglich die Bandstruktur von Quecksilbertellurid- (HgTe-) Quantentrögen als zwei zeitumkehrinvariante Kopien des Chern-Isolators zu interpretieren, was zu einem 2D topologischen Isolator führt. Das Konzept von 2D-TIs wird auf drei Dimensionen erweitert. Eine Einführung in konventio- nelle Supraleitung und insbesondere die mikroskopische Theorie von Bardeen, Cooper und Schrieffer dient einem pädagogischen Zugang zur topologischen Supraleitung. Eine eindimensionale supraleitenden Kette, entwickelt von Alexei Kitaev, dient der Erklärung für die Entstehung von Majorana-Fermionen in p-Wellen Supraleitern. Es ist möglich diesen Zustand durch die Kombination von konventionellen Supraleitern und topologi- schen Isolatoren zu verwirklichen. In dieser Dissertation wird die erwartet topologische Supraleitung in einem sogenannten Josephson-Kontakt untersucht. Dabei wurde vorher- gesagt, dass in einem “topologischen Josephson-Kontakt”die Phase des Suprastromes eine 4π-Periodizität besitzt, während ein normaler Josephson-Kontakt 2π-periodisch ist. Ziel dieser Arbeit ist der experimentelle Nachweis der 4π-Periodizität des Suprastroms in Josephson-Kontakten, die auf HgTe-Bauelementen beruhen. Als Methodik eignet sich die Messung der Shapiro-Plateaus und der Emission des Josephson-Kontaktes an, die ausführlich in den Kapiteln 3 bis 6 werden. In Kapitel 3 wird der Transport in Josephson-Kontakten, die auf dem dreidimensio- nalen topologischen Isolator HgTe beruhen unter Einfluss von Mikrowellenstrahlung detailliert ausgeführt. Dieser Teil beginnt mit einem Überblick über die Eigenschaften von HgTe als dreidimensionaler topologischer Isolator und zeigt insbesondere den Nachweis der Oberfächenleitung von relativistischen Elektronen auf. Des Weiteren wird der Stand der Forschung von Josephson-Kontakten auf diesem Materialsystem dargelegt. In solchen Strukturen werden nämlich aufgrund von Majorana-Fermionen gebundene Andreev- Zustände erwartet, welche sich in der Mitte der supraleitenden Bandlücke (bei null Energie) kreuzen. Sie werden als “gapless Andreev Bound States”bezeichnet. Die Existenz dieser Zustände kann durch den Nachweis einer 4π-Periodizität der Phase des Supra- stroms bewiesen werden. Da die endliche Lebensdauer dieser Zustände “langsamen”dc- Messungen den Nachweis der Periodizität nicht erlauben, wird Strahlung im Gigahertz Frequenzbereich verwendet. Josephson-Kontakte aus 3D-HgTe-Heterostrukturen werden erfolgreich lithografiert. Zunächst werden die Strukturen mit dc-Messungen charakte- risiert und es wird gezeigt, dass der Suprastrom einen Josephson-Effekt aufweist. Die Temperaturabhängigkeit des kritischen Stroms wird simuliert, wodurch die Bestimmung der Größe der induzierten supraleitenden Bandlücke ermöglicht wird. Durch Mikrowel- lenstrahlung entstehen Shapiro-Plateaus in der Strom-Spannungskennlinie I −V -Kurve. Der Spannungsabstand von zwei aufeinander folgenden Plateaus spiegelt die Periodizität des Josephsonstroms wider. Zu erwarten wäre, dass der Abstand in einem topologischen Josephson-Kontakt im Vergleich zu einem konventionellen Josephson-Kontakt doppelt so groß ist (oder anders formuliert: die ungeradzahligen Plateau-Indizes fehlen). In den Strom-Spannungskennlinien wird jedoch beobachtet, dass der erste erwartete Schritt ausbleibt. Alle höheren ungeradzahligen Schritte sind sichtbar. Durch die Untersuchung des Phänomens als Funktion von Mikrowellenfrequenz, Mikrowellenamplitude, Magnet- feldstärke und Probengeometrie wird argumentiert, dass die Ergebnisse der Experimente mit einem topologischen Andreev-Zustand und einer großen Zahl konventioneller Moden vereinbar sind. Um die experimentellen Ergebnisse aus Kapitel 3 nachzuvollziehen, werden in Kapitel 4 die I −V -Kennlinie eines Josephson-Kontaktes mit einer linearen Kombination eines 2π- und eines 4π-periodischen Suprastroms unter Mikrowellenstrahlung numerisch simuliert. Dies erfolgt durch ein Netzwerkmodell, welches aus einem Josephson-Kontakt in Parallelschaltung zu einem ohmschen Widerstand besteht (RSJ-Modell). Die Ergebnisse aus Kapitel 3 können nur durch das Vorhandensein eines 4π-periodischem Suprastroms I4π eindeutig numerisch simuliert werden. Darüber hinaus wird herausgestellt, dass eine Kopplung des Systems an die 4π-periodische Komponente möglich ist, obwohl der Beitrag zum Gesamtstrom Ic sehr klein ist (I4π « Ic ). Die Grundlage für die Experimente in Kapitel 5 bildet ein Josephson-Kontakt, der auf einem invertierten HgTe-Quantentrog basiert. Dieser besitzt helikale Randkanäle, welche mit Supraleitern topologisch geschützte Andreev-Zustände formen. Hierfür ist zuerst ein neuer Lithographieprozess zur Herstellung der Proben entwickelt worden. Da sich der HgTe-Quantentrog unter einer Hg0.3Cd0.7Te-Barriere befindet, muss diese für eine gute induzierte Supraleitung lokal entfernt und der Supraleiter aufgetragen werden, ohne das Vakuum zu brechen. Zur Variation der Ladungsträgerdichte im Josephson-Kontakt wird eine Feldeffektelektrode auf der Struktur platziert. Die Messung des Beugungsmusters des kritischen Stroms als Funktion des Magnetfeldes erlaubt es, die Stromverteilung in der Probe zu untersuchen. Das Beugungsmuster ähnelt dem eines supraleitenden Quanteninterferenzbauelement [engl. Superconducting Quantum Interference Device: (SQUID)] und zeigt, dass der Strom vorwiegend am Rand der Probe fließt. Durch die Bestrahlung mit Mikrowellen werden fehlende ungeradzahlige Shapiro-Plateaus bis zum Stufenindex n = 9 beobachtet. Dies verdeutlicht, dass der Strom eine 4π-periodischen Beitrag aufweist. Das Experiment wird mit einem nicht-invertierten HgTe-Quantentrog wiederholt. Dieser ist nicht in der Quanten-Spin-Hall-Phase und zeigt über den gesamten Parameterbereich alle erwarteten Shapiro-Plateaus, was beweist, dass die Topologie der Probe eine wichtige Eigenschaft ist, um die 4π-Periodizität zu beobachten. Beide Effekte, das SQUID-Beugungsmuster und die verschwindenden ungeradzahligen Shapiro- Plateaus, sind in der Nähe der Quanten-Spin-Phase am sichtbarsten und können daher als Beweis für induzierte topologische Supraleitung in spinpolarisierten Randkanälen interpretiert werden. Eine Messmethode zur direkten Bestimmung der Periodizität des Suprastromes, an- ders als die Verwendung von Shapiro-Plateaus, ist die Messung der Josephson-Emission, was in Kapitel 6 beschrieben wird. Ein topologischer Josephson-Kontakt emittiert Strah- lung bei der halben Josephsonfrequenz f J /2 aufgrund der 4π-Periodizität des Joseph- sonstromes. Hierfür wird ein neuer experimenteller Aufbau entwickelt, um das kleine Emissionssignal eines einzelnen Josephson-Kontaktes zu verstärken. Dieser neue Aufbau erlaubt es, das Spektrum eines invertierten HgTe-Quantentrog zu messen und eine Emis- sion bei f J /2 zu detektieren. Je nach Ladungsträgerdichte und Detektionfrequenz wird auch gewöhnliche Emission bei f J im Spektrum beobachtet. Generell dominiert aber bei niedriger Spannung die f J /2-Emission und bei höheren Spannungen die f J . Da Spannung und ac-Frequenz durch die zweite Josephson-Gleichung proportional zueinander lässt sich das Verhalten mit den Ergebnissen der Shapiro-Plateau-Messungen vereinbaren. Darüber hinaus ist aus der Linienbreite der Emissionssignale eine Lebensdauer für die ABS in der Größenordnung von 0.3 − 4 ns für die f J /2-Emission und 3 − 4 ns für die f J - Emission abgeschätzt worden. Ein nicht-invertierter Quantentrog zeigt im Vergleich zum invertierten nur gewöhnliche Emission bei f J über den gesamten zugänglichen Frequenz- und Ladungsträgerbereich. Im letzten Teil der Arbeit, in Kapitel 7, wird die in den 3D-topologischen Isolator HgTe induzierte Supraleitung mit Hilfe von Andreev-Punktkontaktspektroskopie unter- sucht. Hierfür wird eine HgTe-Struktur mit einer Verengung fabriziert, deren Durchmesser kleiner als die mittlere freie Weglänge der topologischen Oberflächenzustände ist und somit eine energieabhängige Spektroskopie des Zustandes erlaubt. Auf einer Seite der Verengung werden supraleitende Paarkorrelationen durch einen gewöhnlichen Supralei- ter Niob induziert. Diese Struktur ermöglicht daher die Untersuchung der Grenzfläche zwischen einem Supraleiter und einem Normalleiter (topologischer Isolator). Durch die Messung der differentiellen Leitfähigkeit d I /dV als Funktion der dc-Spannung ist es möglich die Energieabhängigkeit der Supraleitung zu untersuchen. Eine induzierte supraleitenden Bandlücke von 70 µeV wird gefunden. Die Leitfähigkeit zeigt Signatu- ren einer weiteren supraleitende Bandlücke des konventionellen Supraleiters Niob von ∆Nb ≈ 1.1 meV. Die Leitfähigkeit wird zum einen mit der Theorie von Blonder, Tinkham und Klapwijk modelliert und zum anderen mit einem erweiterten Modell, welches die 2D Oberflächenzustände des topologischen Isolators berücksichtigt simuliert. Für die Grenzfläche topologischer Isolator mit topologischem Supraleiter wird eine hohe Trans- missionswahrscheinlichkeit (niedrige Barriere) festgestellt, während an der Grenzfläche zwischen dem konventionellen Supraleiter und dem topologischen Isolator eine hohe Barriere in Übereinstimmung mit dem Modell war. Der Transportmechanismus wird durch eine Unterdrückung der induzierten Supraleitung durch eine Nichtgleichgewichts- verteilung der Zustände als Funktion der Spannung erklärt. Die vorliegende Dissertation konnte klare Signaturen von induzierter topologischer Supraleitung in Josephson-Kontakten auf Basis von HgTe-Quantentrögen und Volumen- material aufzeigen. Sie kann auch als Ausgangspunkt für eine große Anzahl von weiter- führenden Experimenten dienen. Die hier entwickelte Technik und auch Theorie kann auf andere topologische Zustände in Verbindung mit Supraleitern angewandt werden. Ein weiteres Experiment für HgTe-Strukturen ließe sich beispielsweise mit Hilfe von su- praleitenden Resonatoren die Spektroskopie und Manipulation der mikroskopischen topologischen Andreev-Zustände durchführen. Diese Technik wurde schon erfolgreich von Janvier et al . auf mechanisch kontrollierten supraleitenden Bruchkontakten ange- wandt [Science 2015, 349, 1199-1202 (2015)]. Eine alternative Technik zur Spektroskopie der Andreev Zustände benötigt konventionelle Josephson-Kontakte in Kombination mit topologischen Kontakten. Die konventionellen Kontakte erlauben die Kontrolle der supra- leitenden Phase und dienen als Spektrometer. Die Andreev-Punktkontaktspektroskopie kann auf zweidimensionale topologische Isolatoren erweitert werden. Auch kann ei- ne supraleitende Schleife, welche die Kontrolle über die Phase und eine veränderbare Barriere ermöglicht, neue Einblicke in die Transportmechanismen geben. Solche Un- tersuchungen bieten Ansatzpunkte für die Lokalisierung von Majorana-Zuständen in Quanten-Spin-Hall-Systemen. KW - Quecksilbertellurid KW - Supraleitung KW - Topologischer Isolator KW - topological insulators KW - Majorana bound state KW - topological superconductor KW - HgTe KW - Josephson junction Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-162782 ER - TY - THES A1 - Wichmann, Tobias T1 - Spulen-Arrays mit bis zu 32 Empfangselementen für den Einsatz an klinischen NMR-Geräten T1 - Coil-Arrays with up to 32 receive channels for the use on clinical NMR systems N2 - In dieser Arbeit wurden für spezielle Anwendungen an klinischen MR-Geräten optimierte Phased-Array-Spulen entwickelt. Das Ziel war, durch die Verwendung neuer Spulen entweder neue Anwendungsgebiete für klinische MR-Geräte zu eröffnen oder bei bestehenden Applikationen die Diagnosemöglichkeiten durch eine Kombination von höherem SNR und kleineren g-Faktoren im Vergleich zu bestehenden Spulen zu verbessern. In Kapitel 3 wurde untersucht, ob es durch den Einsatz neu entwickelter, dedizierter Kleintierspulen sinnvoll möglich ist, Untersuchungen an Kleintieren an klinischen MR-Geräten mit einer Feldstärke von 1,5T durchzuführen. Der Einsatz dieser Spulen verspricht dem klinischen Anwender Studien an Kleintieren durchführen zu können, bei denen er den gleichen Kontrast wie bei einer humanen Anwendung erhält und gleichzeitig Kontrastmittel sowie Sequenzen, die klinisch erprobt sind, einzusetzen. Durch die gewählten geometrischen Abmessungen der Spulen ist es möglich, Zubehör von dedizierten Tier-MR-Geräten, wie z. B. Tierliegen oder EKG- bzw. Atemtriggereinheiten, zu verwenden. Durch Vorversuche an für Ratten dimensionierten Spulen wurden grundlegende Zusammenhänge zwischen verwendetem Entkopplungsmechanismus und SNR bzw. Beschleunigungsfähigkeit erarbeitet. Für Ratten wurde gezeigt, dass in akzeptablen Messzeiten von unter fünf Minuten MR-Messungen des Abdomens in sehr guter Bildqualität möglich sind. Ebenfalls gezeigt wurde die Möglichkeit durch den Einsatz von paralleler Bildgebung sowie Kontrastmitteln hochaufgelöste Angiographien durchzuführen. Es stellte sich heraus, dass bei 1,5T dedizierte Mäusespulen bei Raumtemperatur von den SNR-Eigenschaften am Limit des sinnvoll Machbaren sind. Trotzdem war es möglich, auch für Mäuse ein 4-Kanal-Phased-Array zu entwickeln und den Einsatz bei kontrastmittelunterstützten Applikationen zu demonstrieren. Insgesamt wurde gezeigt, dass durch den Einsatz von speziellen, angepassten Kleintierspulen auch Tieruntersuchungen an klinischen MR-Geräten mit niedriger Feldstärke durchführbar sind. Obwohl sich die Bestimmung der Herzfunktion an MR-Geräten im klinischen Alltag zum Goldstandard entwickelt hat, ist die MR-Messung durch lange Atemanhaltezyklen für einen Herzpatienten sehr mühsam. In Kapitel 4 wurde deswegen die Entwicklung einer 32-Kanal-Herzspule beschrieben, welche den Komfort für Patienten deutlich erhöhen kann. Schon mit einem ersten Prototypen für 3T war es möglich, erstmals Echtzeitbildgebung mit leicht reduzierter zeitlicher Auflösung durchzuführen und damit auf das Atemanhalten komplett zu verzichten. Dies ermöglicht den Zugang neuer Patientengruppen, z. B. mit Arrythmien, zu MR-Untersuchungen. Durch eine weitere Optimierung des Designs wurde das SNR sowie das Beschleunigungsvermögen signifikant gesteigert. Bei einem Beschleunigungsfaktor R = 5 in einer Richtung erhält man z. B. gemittelt über das gesamte Herz ein ca. 60 % gesteigertes SNR zu dem Prototypen. Die Kombination dieser Spule zusammen mit neuentwicklelten Methoden wie z. B. Compressed- Sensing stellt es in Aussicht, die Herzfunktion zukünftig in der klinischen Routine in Echtzeit quantifizieren zu können. In Kapitel 5 wurde die Entwicklung einer optimierten Brustspulen für 3T beschrieben. Bei Vorversuchen bei 1,5T wurden Vergleiche zwischen der Standardspule der Firma Siemens Healthcare und einem 16-Kanal-Prototypen durchgeführt. Trotz größerem Spulenvolumen zeigt die Neuentwicklung sowohl hinsichtlich SNR als auch paralleler Bildgebungseigenschaften eine signifikante Verbesserung gegenüber der Standardspule. Durch die Einhaltung aller Kriterien für Medizinprodukte kann diese Spule auch für den klinischen Einsatz verwendet werden. Mit den verbesserten Eigenschaften ist es beispielsweise möglich, bei gleicher Messdauer eine höhere Auflösung zu erreichen. Aufgrund des intrinsischen SNR-Vorteils der 3 T-Spule gegenüber der 1,5 T-Spule ist es dort sogar möglich, bei höheren Beschleunigungsfaktoren klinisch verwertbare Schnittbilder zu erzeugen. Zusammenfassend wurden für alle drei Applikationen NMR-Empfangsspulen entwickelt, die im Vergleich zu den bisher verfügbaren Spulen, hinsichtlich SNR und Beschleunigungsvermögen optimiert sind und dem Anwender neue Möglichkeiten bieten. N2 - Purpose of this work was to develop optimized phased array coils for clinical magnetic resonance imaging (MRI) systems for applications were dedicated coils were not readily available. Chapter 3 evaluates the use of dedicated small animal coils on clinical MR scanners with a field strength of 1,5T instead of using special animal-systems with higher intrinsic signal-to-noise ratio. Advantage of the clinical system is the availability and the portability of the results of animal studies to human applications because sequences can easily be adopted. The available contrast is similar and clinically tested contrast agents can directly be used. Comparisons of different array decoupling methods with respect to SNR and parallel imaging performance have been conducted on coils with the standard size of rat-coils on animal scanners as part of this work. This geometry made it possible to directly use accessories of these systems like animal beds and monitoring systems. It showed that it is possible to acquire images of the abdomen of the rat in under five minutes in very good image quality with such setup. It was also used for high resolution angiographie in very short scanning time due to the use of parallel imaging techniques. However it has shown that the use of dedicated mouse coils is at the very limit of SNR at 1.5 T. Nevertheless a four channel phased array coil was built and tested. The results are described within this work. Another application which can benefit of novel dedicated coils is the assessment of cardiac function. Especially for heart patients it can be very exhausting to hold breath for a longer period of time, which is required by the current standard protocol for cardiac imaging. The combination of 3T and many available receive channels is a very promising combination to shorten the scan time. Chapter 4 describes the development of a 32 channel cardiac phased array coil for 3T to investigate this idea. Starting with an existing coil for 1.5T a first prototype was developed which was the first coil to demonstrate real-time cardiac imaging with only slightly reduced temporal resolution. A further optimization of this coil led to a completely new coil with higher SNR performance and better parallel imaging abilities and was a further step towards real-time imaging of the heart in clinical routine. Chapter 5 describes the development of an optimized 16 channel breast coil for 3T which can be used in clinical routine. Tests at 1.5T were conducted to find the best coil element layout . It was also possible to compare the prototypes at this field strength to an existing breast coil of Siemens Healthcare. Better SNR and parallel imaging performance could be achieved due to the possibility of adjusting the coil size to different breast sizes and therefore optimizing the filling factor. These improved qualities will allow to have higher resolution in the same scan time compared to the current standard in clinical routine. In conclusion it has been shown that these applications can benefit from dedicated array coils due to better SNR and parallel imaging performance. KW - Kernspintomografie KW - NMR-Tomographie KW - Spulen-Array KW - magnetic resonance imaging KW - coil-array KW - Magnetspule KW - Magnetische Kernresonanz Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-79358 ER - TY - THES A1 - Wenisch, Jan T1 - Ferromagnetic (Ga,Mn)As Layers and Nanostructures: Control of Magnetic Anisotropy by Strain Engineering T1 - Ferromagnetische (Ga,Mn)As Schichten und Nanostrukturen: Kontrolle der magnetischen Anisotropie durch Manipulation der Kristallverspannung N2 - This work studies the fundamental connection between lattice strain and magnetic anisotropy in the ferromagnetic semiconductor (Ga,Mn)As. The first chapters provide a general introduction into the material system and a detailed description of the growth process by molecular beam epitaxy. A finite element simulation formalism is developed to model the strain distribution in (Ga,Mn)As nanostructures is introduced and its predictions verified by high-resolution x-ray diffraction methods. The influence of lattice strain on the magnetic anisotropy is explained by an magnetostatic model. A possible device application is described in the closing chapter. N2 - Die vorliegende Arbeit untersucht den fundamentalen Zusammenhang zwischen Gitterverspannung und magnetischer Anisotropie in dem ferromagnetischen Halbleiter (Ga,Mn)As. Die ersten Kapitel bieten eine allgemeine Einleitung in das Materialsystem und eine detaillierte Beschreibung des Wachstumsprozesses mittels Molekularstrahlepitaxie. Eine Finite-Elemente Simulation wird entwickelt, um die Verteilung der Gitterverspannung in (Ga,Mn)As Nanostrukturen zu modellieren. Die daraus abgeleiteten Vorhersagen werden mittels hochauflösender Röntgenbeugung bestätigt. Der Einfluss der Gitterverspannung auf die magnetische Anisotropie wird anhand eines magnetostatischen Modells erklärt. Das abschließende Kapitel gibt einen Ausblick auf eine mögliche praktische Anwendung der beschriebenen Phänomene. KW - Magnetischer Halbleiter KW - Drei-Fünf-Halbleiter KW - Ferromagnetismus KW - Magnetoelektronik KW - Bandstrukturberechnung KW - Molekularstrahlepitaxie KW - Elastische Spannung KW - Computersimulation KW - Röntgenbeugung KW - GaMnAs KW - Ferromagnetic Semiconductors KW - Magnetic Anisotropy KW - Molecular Beam Epitaxy KW - Strain Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-34552 ER - TY - THES A1 - Weißenseel, Sebastian Günter T1 - Spin-Spin Interactions and their Impact on Organic Light-Emitting Devices T1 - Spin-Spin-Wechselwirkungen und ihre Einflüsse auf organische Leuchtdioden N2 - This work investigates the correlations between spin states and the light emission properties of organic light-emitting diodes (OLEDs), which are based on the principle of thermally activated delayed fluorescence. The spin-spin interactions responsible for this mechanism are investigated in this work using methods based on spin-sensitive electron paramagnetic resonance (EPR). In particular, this method has been applied to electrically driven OLEDs. The magnetic resonance has been detected by electroluminescence, giving this method its name: electroluminescence detected magnetic resonance (ELDMR). Initial investigations on a novel deep blue TADF emitter were performed. Furthermore, the ELDMR method was used in this work to directly detect the spin states in the OLED. These measurements were further underlined by time-resolved experiments such as transient electro- and photoluminescence. N2 - Diese Arbeit untersucht die Zusammenhänge zwischen Spinzuständen und den Lichtemissions Eigenschaften von Organischen Leuchtdioden (OLEDs), welche auf dem Prinzip der thermisch aktivierten verzögerten Fluoreszenz basieren. Die für diesen Mechanismus verantwortlichen Spin-Spin-Wechselwirkungen werden im Rahmen der Arbeit mit Methoden untersucht, die auf der spinsensitiven Elektron Paramagnetische Resonanz (EPR) basieren. Insbesondere wurde diese Methode auf elektrisch betriebene OLEDs angewendet und die magnetische Resonanz durch Elektrolumineszenz nachgewiesen, was dieser Methode ihren Namen verleiht: Elektrolumineszenz detektierte magnetische Resonanz (ELDMR). Erste Untersuchungen an einem neuartigen tiefblauen TADF-Emitters wurden durchgeführt. Ebenfalls konnte in dieser Arbeit mit Hilfe der ELDMR-Methode direkt die Spinzustände in der OLED detektiert werden. Unterstützt wurden diese Messungen von Zeit-aufgelösten Experimenten wie transiente Elektro- und Photolumineszenz. KW - Elektronenspinresonanz KW - Technische Optik KW - Nanometerbereich KW - Organische Leuchtdioden KW - OLED Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-257458 ER - TY - THES A1 - Weinläder, Helmut T1 - Optische Charakterisierung von Latentwärmespeichermaterialien zur Tageslichtnutzung T1 - Optical characterization of phase change materials for daylighting N2 - In dieser Arbeit wurde untersucht, inwieweit sich durch den Einsatz von Latentwärmespeichermaterialien (kurz PCM = phase change material) Tageslichtelemente realisieren lassen, welche einen Teil der eingestrahlten Solarenergie zwischenspeichern und zeitverzögert während der Abend- und Nachtstunden wieder an den Innenraum abgeben. Hierdurch lassen sich mehrere Effekte erzielen: Der bei Verglasungen auftretende starke Wärmeeintrag während des Tages wird gedämpft und bis in die Abend- und Nachtstunden ausgedehnt. Im Sommer führt dies zu geringeren Kühllasten. Die zeitlich verzögerten abends auftretenden Wärmeeinträge können bei Bedarf über Nachtlüftung abgeführt werden. Im Winter sind die solaren Gewinne zeitlich besser mit den Wärmeverlusten korreliert was ihren Nutzungsgrad erhöht. Dies führt zu geringerem Heizenergiebedarf. Weiter wird im Winter aufgrund der Erhöhung der Systemoberflächentemperatur durch den Phasenwechsel des PCM die thermische Behaglichkeit in den Abendstunden vor allem in Systemnähe gesteigert. Im Sommer bleiben die Oberflächentemperaturen tagsüber niedrig, sofern ein PCM mit entsprechender Schmelztemperatur (<30°C) gewählt wird, so dass auch zu diesen Zeiten die thermische Behaglichkeit verbessert wird. Es wurden drei Latentwärmespeichermaterialien untersucht: ein Paraffin (RT25), sowie zwei Salzhydrate auf Basis von Kalziumchloridhexahydrat (S27) und Lithiumnitrattrihydrat (L30). Aus Messwerten des Transmissions- und Reflexionsgrades im flüssigen Zustand wurden die spektralen Daten der Brechungsindizes ermittelt. Strukturuntersuchungen der PCMs im festen Zustand erfolgten mittels Lichtmikroskopie und anhand von Streuverteilungsmessungen. Diese wurden mit der Mie-Theorie ausgewertet. Es wurde bei allen Materialien die Ausbildung einer Makrostruktur festgestellt, die wiederum mit einer Mikrostruktur unterlegt ist. Die Makrostruktur entsteht durch Grenzflächen Festkörper-Luft beim Erstarren und Zusammenziehen der Materialien, die Mikrostruktur durch sehr feine Lufteinschlüsse und Grenzflächen innerhalb des Festkörpergerüsts. Während die Makrostruktur vor allem bei den Salzhydraten in ihrer Größe variiert und sich an die Behälterdicke anpasst, liegt die Größe der Mikrostrukturen bei allen drei Materialien relativ konstant im Bereich um die 5-20 µm. Die Mikrostrukturen sind für die Lichtstreuung verantwortlich. Unter der Annahme, dass die Werte der Brechungsindizes im festen und flüssigen Zustand gleich sind, wurden mit dem 3-Fluss-Modell die spektralen effektiven Streukoeffizienten der festen PCMs bestimmt. Mit den ermittelten Größen lassen sich die optischen Eigenschaften der Materialien im festen und flüssigen Zustand für Schichtdicken zwischen 1,5 mm und 4 cm berechnen. Alle drei Materialien zeigen eine hohe Transmission im sichtbaren Spektralbereich und eine starke Absorption im Nahinfraroten. Dieses Verhalten ist für den Einsatz in Tageslichtelementen günstig, da man dort das sichtbare Licht zur Raumausleuchtung nutzen und den nahinfraroten Anteil in Form von Wärme speichern will. Für den Einsatz im Tageslichtelement müssen die PCMs auslaufsicher in Behälter eingebracht werden. Hierfür wurden Stegdoppelplatten (SDP) aus Plexiglas verwendet. Zwei Funktionsmuster mit RT25 und S27, bestehend aus einer Wärmeschutzverglasung, hinter der die PCM-befüllten SDPs angebracht waren, wurden unter natürlichen Klimabedingungen vermessen. Die Messdaten dienten zur Validierung eines Simulationsprogramms, mit dem das Verhalten der drei PCM-Tageslichtelemente unter genormten Bedingungen im Sommer- und Winterbetrieb untersucht wurde. Messungen und Simulationsrechnungen ergaben, dass die gewünschten Effekte (Dämpfung der Energiegewinne tagsüber, Verschiebung der Gewinne vom Tag in die Abend- und Nachtstunden, sowie Verbesserung der thermischen Behaglichkeit) mit den PCM-Tageslichtelementen erreicht werden. Anhand von Optimierungsrechnungen wurde gezeigt, dass die Energieeinkopplung in das PCM erhöht werden muss. Dies kann durch Beimengung absorbierender Materialien in das PCM oder durch Verwendung von Behältern mit höherer Absorption geschehen. Bei derart optimierten Tageslichtelementen sind Schichtdicken von rund 5 mm PCM ausreichend. Lichttechnische Untersuchungen ergaben, dass die Tageslichtelemente mit PCM oft ein stark inhomogenes optisches Erscheinungsbild zeigen, vor allem während des Phasenwechsels. Deshalb sollten für den Einsatz in der Praxis Möglichkeiten zur Kaschierung vorgesehen werden. Dies lässt sich z.B. durch streuende Behälter erreichen. Problematisch ist die Dichtigkeit der Behälter, vor allem wenn Salzhydrate als PCM verwendet werden. Die Kristalle üben beim Wachstum starke Kräfte auf die Behälterwandungen aus, so dass diese besonders bei größeren Behälterabmessungen dem Druck nicht standhalten und Risse bilden. Hier ist noch Entwicklungsarbeit zu leisten. N2 - This thesis investigates the suitability of phase change materials (PCMs) as energy storage in daylighting elements. PCMs store part of the incoming solar radiation on sunny days while releasing the stored heat during the evening hours and the night. This time shift in solar energy gains reduces cooling loads in summer, especially if combined with night-time ventilation. In winter, solar energy gains correlate much better with the heating demand of buildings, thus reducing fuel consumption. In addition, the higher system temperatures due to the phase change improve thermal comfort during the evening hours. If PCMs with low melting points (<30°C) are used, the system temperatures stay cool even on hot summer days. This improves thermal comfort in summer as well. Three different PCMs were investigated: a paraffin wax (RT25) and two salt hydrates with calciumchloridehexahydrate (S27) and lithiumnitratetrihydrate (L30) as base materials. The spectral refractive indices in liquid state were calculated from measured transmittance and reflectance values. In solid state, microscopy and scattering measurements in combination with Mie-calculactions were used to determine the size of the structures responsible for scattering. All three PCMs showed macroscopic structuring with microstructures embedded. Air gaps generated through volume decrease during solidification of the materials cause the macroscopic structuring. The microstructures are due to very fine air bubbles and solid-solid boundaries. While the macroscopic structuring varies in size - especially the salt hydrates adjust to the dimensions of the confinement - the size of the microstructures is in the range between 5-20 µm for all of the materials. The microstructures are responsible for the scattering of light. With the assumption of non-changing refractive indices in liquid and solid state, the spectral effective scattering coefficients were calculated for the three PCMs in solid state via 3-flux-theory. The determined optical data were sufficient to calculate the optical properties of all three materials in liquid and solid state for a layer thickness between 1.5 mm and 4 cm. All PCMs show high transmission values in the visible wavelength range and high absorption in the NIR. This makes them very suitable for daylighting applications where the visible light is needed for room illumination and the NIR needs to be stored in the PCM as heat. For application as daylighting elements the PCM must be encapsulated. This was done by use of plastic containers, so-called double-skin sheets. Two samples with RT25 and S27 were built and incorporated into an outdoor measurement facility. The samples consisted of PCM-filled double-skin sheets behind a low-e-glazing. A simulation program was validated with the recorded data. This program was used to investigate the performance of the three PCM-daylighting-elements for winter and summer conditions. The above-mentioned effects (decrease in energy gains during the day, time-shift of energy gains into the evening hours and improvement of thermal comfort) could be verified. To optimize the daylighting-elements, the energy input into the PCM should be enhanced. This can be done by adding high-absorbing materials into the PCM or by using containers with higher absorption. In such optimized panels a PCM-thickness of 5 mm is sufficient. The system visual performance often had a very inhomogeneous appearance, especially during the melting and freezing process of the PCM. Therefore it is recommended to conceal these effects by using translucent containers with scattering properties instead of transparent ones. A major problem is the container tightness, especially if a salt hydrate is used as PCM. The crystal growth during the freezing process causes considerable stress on the containers which leads to cracks in bigger ones. This has to be worked on. KW - Tageslichtelement KW - Latentwärmespeicher KW - Strahlungstransport KW - Tageslichtnutzung KW - Latentwärmespeicher KW - PCM KW - Verglasung KW - radiation transport KW - daylighting KW - latent heat KW - phase change material KW - energy storage Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-7872 ER - TY - THES A1 - Weinhardt, Lothar T1 - Elektronische und chemische Eigenschaften von Grenzflächen und Oberflächen in optimierten Cu(In,Ga)(S,Se)2 Dünnschichtsolarzellen T1 - Electronical and chemical properties of interfaces and surfaces in optimized Cu(In,Ga)(S,Se)2 thin film solar cells N2 - In der vorliegenden Arbeit wurden Untersuchungen an Dünnschichtsolarzellen auf der Basis von Cu(In,Ga)(S,Se)2, der heute vielversprechendsten Dünnschichttechnologie, durchgeführt. Für eine weitere Optimierung der Zellen ist ein detailliertes Verständnis ihrer chemischen, elektronischen und strukturellen Eigenschaften notwendig. Insbesondere die in dieser Arbeit untersuchten Eigenschaften an den Grenzflächen der Zelle sind aufgrund ihrer zentralen Rolle für den Ladungsträgertransport von besonderem Interesse. Bei den vorliegenden Untersuchungen kamen verschiedene Spektroskopien zum Einsatz. Mit einer Kombination von Photoelektronenspektroskopie und Inverser Photoelektronenspektroskopie war es möglich, sowohl eine direkte Bestimmung der Valenz- und Leitungsbandanpassungen an den untersuchten Grenzflächen durchzuführen als auch Oberflächenbandlücken zu bestimmen. Die Messungen wurden durch die volumenempfindliche Röntgenemissionsspektroskopie ideal ergänzt, die - wie diese Arbeit zeigt - zusammen mit der Photoelektronenspektroskopie besonders nützlich bei der Analyse des Durchmischungsverhaltens an Grenzflächen oder auch des Einflusses chemischer Behandlungen auf die chemischen und elektronischen Eigenschaften von Oberflächen ist. Im ersten Teil der Arbeit wurden vier Grenzflächen in Proben auf der Basis des Cu(In,Ga)(S,Se)2-Absorbers von Shell Solar (München) untersucht. Es konnte dabei zunächst das Durchmischungsverhalten an der CdS/CuIn(S,Se)2-Grenzfläche in Abhängigkeit des S-Gehaltes an der Absorberoberfläche untersucht werden. Bei Messungen an der i-ZnO/CdS-Grenzfläche wurde ein flacher Leitungsbandverlauf gefunden, zudem konnte eine Durchmischung an dieser Grenzfläche ausgeschlossen werden. Eine besondere Herausforderung stellten die Messungen an der Grenzfläche des Absorbers zum Molybdänrückkontakt dar, da diese Grenzfläche nach ihrem Entstehen unweigerlich unter der etwa 1-2 um dicken Absorberschicht begraben liegt. Durch geeignetes Abspalten des Absorbers vom Rückkontakt gelang es, diese Grenzfläche freizulegen und zu spektroskopieren. Die Untersuchungen zur Vorbehandlung des Shell-Absorbers mit einer ammoniakalischen Cd-Lösung dienten dem Verständnis der positiven Einflüsse dieser Behandlung auf den Zellwirkungsgrad. Dabei wurde neben verschiedenen Reinigungswirkungen auf den Absorber als wichtigster Befund die Bildung einer sehr dünnen CdS-Schicht und, für hohe Cd-Konzentrationen, einer zusätzlichen Cd(OH)2-Schicht auf der Absorberoberfläche nachgewiesen. Die gewonnenen Erkenntnisse über die Cd-Behandlung haben eine besondere Bedeutung für die Untersuchung der Grenzfläche des Absorbers und einer mit ILGAR ("Ion Layer Gas Reaction") hergestellten Zn(O,OH)-Pufferschicht. An dieser Grenzfläche wurde die Bandanpassung mit und ohne vorherige Cd-Behandlung des Absorbers vermessen. Wird die Bandanpassung ohne Vorbehandlung noch durch Adsorbate auf dem Absorber dominiert, wobei man ein "Cliff" im Leitungsband findet, so ist der Leitungsbandverlauf für die Grenzfläche mit Cd-behandeltem Absorber flach, was im Einklang mit den sehr guten Wirkungsgraden steht, die mit solchen Zellen erreicht werden. Im zweiten Teil der Arbeit wurden Messungen an Dünnschichtsolarzellen mit selenfreiem Cu(In,Ga)S2 Absorber diskutiert. Ein Problem des Cu(In,Ga)S2-Systems besteht heute noch darin, daß die offene Klemmenspannung geringer ausfällt, als dies aufgrund der im Vergleich zu CuInSe2 größeren Bandlücke zu erwarten wäre. Modelle, die dies auf eine ungünstige Bandanpassung an der CdS/Cu(In,Ga)S2-Grenzfläche zurückführen, konnten in dieser Arbeit durch die Messung der Leitungsbandanpassung, die ein deutlich "Cliff"-artiges Verhalte aufweist, bestätigt werden. Untersuchungen des Einflusses unterschiedlicher Oberflächenzusammensetzungen auf die chemischen und elektronischen Eigenschaften der Cu(In,Ga)Se2-Absorberoberfläche ergaben, wie sich die Bandlücke des Absorbers mit wachsender Kupferverarmung vergrößert und gleichzeitig die Bandverbiegung zunimmt. Im letzten, rein grundlagenorientierten Teil dieser Arbeit wurden Röntgenabsorptions- und resonante Röntgenemissionsmessungen an CdS und ZnS im Vergleich zu von A. Fleszar berechneten theoretischen Spektren, die unter Berücksichtigung der Übergangsmatrixelemente aus einer LDA-Bandstruktur berechnet wurden, diskutiert. Es konnten dabei sowohl Anregungen in exzitonische Zustände als auch kohärente Emission mit Informationen über die Bandstruktur gefunden werden. Auch war es möglich, die Lebensdauern verschiedener Valenzlochzustände zu bestimmen. Es zeigt sich, daß so die Bestimmung einer unteren Grenze für die Bandlücke möglich ist, für eine genaue Bestimmung bei den untersuchten Verbindungen jedoch ein Vergleich mit theoretischen Berechnungen notwendig ist. N2 - In this thesis, thin film solar cells based on Cu(In,Ga)(S,Se)2 - today's most promising thin film solar cell technology - were spectroscopically analyzed in some detail. Until now, good results could be obtained mainly by empirically optimizing the process parameters, but a further optimization calls for a fundamental understanding of the Cu(In,Ga)(S,Se)2 solar cell. Since this device is a multilayer system, a detailed knowledge of the chemical, structural, and electronic properties of its interfaces is required. Partly due to the cost effective production process of the Cu(In,Ga)(S,Se)2 thin film solar cells, their properties are very different from ideal reference systems like single crystals, which makes them a particularly interesting research field. However, this requires the consideration of two aspects: the investigated samples should originate as close as possible from the industrial production process and, when investigating interfaces, their properties have to be measured directly without relying on previously published bulk properties. Both aspects have been achieved in this work. Samples were directly taken from the production process of different collaboration partners, and a direct determination of the conduction and valence band alignments, which are crucial for the carrier transport through the cell device, were conducted by a combination of photoelectron spectroscopy and inverse photoemission. These techniques were ideally complemented by x-ray emission spectroscopy, which can be particular helpful when investigating intermixing processes or the influence of chemical treatments on the chemical and electronic properties of surfaces. In the first part of this thesis, four different interfaces in samples based on the Cu(In,Ga)(S,Se)2 absorber of Shell Solar were investigated. It could be shown, that the intermixing of sulfur and selenium at the CdS/Cu(In,Ga)(S,Se)2 interface found in earlier measurements is dependent on the sulfur content at the absorber surface. Next, the interface between the CdS buffer layer and the i-ZnO part of the window layer was investigated. For this interface, an intermixing can be excluded and a flat conduction band offset is found. By suitably removing the absorber from the back contact, it was possible to investigate the interface between the absorber and the Mo back contact with spectroscopic techniques giving insight into the chemical properties of this interface. The chemical treatment of the absorber by an ammonia-based Cd-solution was investigated for a better understanding of its beneficial impact on the cell performance. Apart from a cleaning of the absorber, the main finding was the formation of a very thin CdS/CdSe layer and, for high Cd-concentrations, of an additional Cd(OH)2 layer on the absorber surface. The investigated Cd-treatment significantly improves the performance of cells with a Zn(O,OH) buffer layer deposited with ILGAR ("Ion Layer Gas Reaction"). The band alignment at the interface between ILGAR Zn(O,OH) and the absorber was investigated with Cd-treated and untreated absorbers. In the second part of this thesis, measurements of thin film solar cells with selenium-free Cu(In,Ga)S2 absorbers are discussed. These absorbers have a larger band gap than CuInSe2, which gives them the potential of higher efficiencies. However, the gain in the open circuit voltage is smaller than expected raising one of the most important questions in the CIGSSe community. In this thesis, this question is answered by a model, that ascribes this behavior to an unfavorable band alignment at the CdS/Cu(In,Ga)S2 interface. The model is supported by the measurement of the band alignment showing a pronounced "cliff" in the conduction band. The investigation of the influence of different absorber surface compositions on the chemical and electronic properties of the Cu(In,Ga)Se2 surface shows, that the surface band gap is increased by increasing copper depletion. These measurements are an important contribution to the understanding of the different recombination behaviors and efficiencies of cells with copper-rich and copper-poor absorbers. In the last part of this thesis, x-ray absorption and resonant x-ray emission spectra of CdS and ZnS (i.e. the currently preferred buffer material (CdS) as well as one of its most promising alternatives (ZnS) for Cu(In,Ga)(S,Se)2 solar cells) were discussed and compared to calculations of A. Fleszar. In these calculations theoretical spectra were obtained ad hoc using an LDA band structure taking the transition matrix elements into account. Thereby valuable information about the band structure could be extracted from the coherent emission in the resonant spectra. Moreover lifetimes of different valence hole states were determined with the surprising observation of an 1.5 eV lifetime broadening of the S 3s deep valence hole. KW - Dünnschichtsolarzelle KW - Oberfläche KW - Elektronische Eigenschaft KW - Grenzfläche KW - Oberflächenchemie KW - Grenzflächenchemie KW - Photoelektronenspektroskopie KW - Röntgenemission KW - Inverse Photoemission KW - Solarzellen KW - Halbleitergrenzflächen KW - photoelectron spectrscopy KW - x-ray emission KW - inverse photoemission KW - solar cells KW - semiconductor interfaces Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-16234 ER - TY - THES A1 - Weih, Robert T1 - Interbandkaskadenlaser für die Gassensorik im Spektralbereich des mittleren Infrarot T1 - Interband Cascade Lasers for Gas Sensing in the Mid Infrared Spectral Region N2 - Aufgrund der hohen Sensitivität bei der Absorptionsmessung von Gasen im Spektral- bereich des mittleren Infrarot steigt die Nachfrage nach monolithischen, kompakten und energieeffizienten Laserquellen in Wellenlängenfenster zwischen 3 und 6 μm ste- tig. In diesem Bereich liegen zahlreiche Absorptionsbanden von Gasen, welche sowohl in der Industrie als auch in der Medizintechnik von Relevanz sind. Mittels herkömm- licher Diodenlaser konnte dieser Bereich bisher nur unzureichend abgedeckt werden, während Quantenkaskadenlaser infolge ihrer hohen Schwellenleistungen vor allem für portable Anwendungen nur bedingt geeignet sind. Interbandkaskadenlaser kom- binieren die Vorteile des Interbandübergangs von konventionellen Diodenlasern mit der Möglichkeit zur Kaskadierung der Quantenkaskadenlaser und können einen sehr breiten Spektralbereich abdecken. Das übergeordnete Ziel der Arbeit war die Optimierung von molekularstrahlepitak- tisch hergestellten Interbandkaskadenlasern auf GaSb - Basis im Spektralbereich des mittleren Infrarot für den Einsatz in der Gassensorik. Dies impliziert die Ermögli- chung von Dauerstrichbetrieb bei Raumtemperatur, das Erreichen möglichst geringer Schwellenleistungen sowie die Entwicklung eines flexiblen Konzepts zur Selektion von nur einer longitudinalen Mode. Da die Qualität der gewachsenen Schichten die Grundvoraussetzung für die Herstel- lung von performanten Bauteilen darstellt, wurde diese im Rahmen verschiedener Wachstumsserien eingehend untersucht. Nachdem das Flussverhältnis zwischen den Gruppe -V Elementen Sb und As ermittelt werden konnte, bei dem die InAs/AlSb - Übergitter der Mantelschichten verspannungskompensiert hergestellt werden können, wurde die optimale Substrattemperatur beim Wachstum dieser zu 450 ◦C bestimmt. Anhand von PL - sowie HRXRD- Messungen an Testproben konnte auch die opti- male Substrattemperatur beim Wachstum der charakteristischen W- Quantenfilme zu 450 ◦C festgelegt werden. Als weiterer kritischer Parameter konnte der As - Fluss beim Wachstum der darin enthaltenen InAs - Schichten identifiziert werden. Die bes- ten Ergebnisse wurden dabei mit einem As - Fluss von (1.2 ± 0.2) × 10−6 torr erzielt. Darüber hinaus konnte in Kooperation mit der Technischen Universität Breslau eine sehr hohe guteWachstumshomogenität auf den verwendeten 2′′ großen GaSb -Wafern nachgewiesen werden. Im Anschluss an die Optimierung des Wachstums verschiedener funktioneller Be- standteile wurden basierend auf einem in der Literatur veröffentlichten Laserschicht- aufbau diverse Variationen mit dem Ziel der Optimierung der Laserkenndaten unter- sucht. Zum Vergleich wurden 2.0 mm lange und 150 μm breite, durch die aktive Zone geätzte Breitstreifenlaser herangezogen. Eine erhebliche Verbesserung der Kenndaten konnte durch die Anwendung des Kon- zepts des Ladungsträgerausgleichs in der aktiven Zone erreicht werden. Bei einer Si - Dotierkonzentration von 5.0 × 1018 cm−3 in den inneren vier InAs - Filmen des Elektroneninjektors konnte die niedrigste Schwellenleistungsdichte von 491W/cm2 erreicht werden, was einer Verbesserung von 59% gegenüber des Referenzlasers ent- spricht. Mithilfe längenabhängiger Messungen konnte gezeigt werden, dass der Grund für die Verbesserung in der deutlichen Reduzierung der internen Verluste auf nur 11.3 cm−1 liegt. Weiterhin wurde die Abhängigkeit der Laserkenngrößen von der Anzahl der verwendeten Kaskaden in den Grenzen von 1 bis 12 untersucht. Wie das Konzept der Kaskadierung von Quantenfilmen erwarten ließ, wurde eine mo- notone Steigerung des Anstiegs der Strom - Lichtleistungskennlinie sowie eine Pro- portionalität zwischen der Einsatzspannung und der Kaskadenzahl nachgewiesen. Für ICLs mit einer gegebenen Wellenleiterkonfiguration und einer Wellenlänge um 3.6 μm wurde bei einer Temperatur von 20 ◦C mit 326W/cm2 die niedrigste Schwel- lenleistungsdichte bei einem ICL mit vier Kaskaden erreicht. Des Weiteren konnte für einen ICL mit 10 Kaskaden und einer Schwellenstromdichte von unter 100A/cm2 ein Bestwert für Halbleiterlaser in diesem Wellenlängenbereich aufgestellt werden. Eine weitere Reduktion der Schwellenleistungsdichte um 24% konnte anhand von Lasern mit fünf Kaskaden durch die Reduktion der Te - Dotierung von 3 × 1017 cm−3 auf 4 × 1016 cm−3 im inneren Teil der SCLs erreicht werden. Auch hier wurde mit- tels längenabhängiger Messungen eine deutliche Reduktion der internen Verluste nachgewiesen. In einer weiteren Untersuchung wurde der Einfluss der SCL - Dicke auf die spektralen sowie elektro - optischen Eigenschaften untersucht. Darüber hin- aus konnten ICLs realisiert werden, deren Mantelschichten nicht aus kurzperiodigen InAs/AlSb - Übergittern sondern aus quaternärem Al0.85Ga0.15As0.07Sb0.93 bestehen. Für einen derartig hergestellten ICL konnte eine Schwellenstromdichte von 220A/cm2 bei einer Wellenlänge von 3.4 μm gezeigt werden. Mithilfe der durch die verschiedenen Optimierungen gewonnenen Erkenntnisse so- wie Entwurfskriterien aus der Literatur wurden im Rahmen diverser internationaler Kooperationsprojekte ICLs bei verschiedenen Wellenlängen zwischen 2.8 und 5.7 μm hergestellt. Der Vergleich der Kenndaten zeigt einen eindeutigen Trend zu einer stei- genden Schwellenstromdichte mit steigender Wellenlänge. Die charakteristische Tem- peratur der untersuchten Breitstreifenlaser nimmt von circa 65K bei lambda=3.0 μm mit steigender Wellenlänge auf ein Minimum von 35K im Wellenlängenbereich um 4.5 μm ab und steigt mit weiter steigender Wellenlänge wieder auf 45K an. Ein möglicher Grund für dieses Verhalten konnte mithilfe von Simulationen in der Anordnung der Valenzbänder im W-Quantenfilm gefunden werden. Zur Untersuchung der Tauglichkeit der epitaktisch hergestellten Schichten für den in der Anwendung hilfreichen Dauerstrichbetrieb oberhalb von Raumtemperatur wur- den Laser in Stegwellenleitergeometrie mit einer aufgalvanisierten Goldschicht zur verbesserten Wärmeabfuhr hergestellt. Nach dem Aufbau der Laser auf Wärmesen- ken wurde der Einfluss der Kavitätslänge sowie der Stegbreite auf diverse Kennda- ten untersucht. Des Weiteren wurden eine Gleichung verifiziert, welche es erlaubt die maximal erreichbare Betriebstemperatur im Dauerstrichbetrieb aus der auf die Schwellenleistung bezogenen charakteristischen Temperatur sowie dem thermischen Widerstand des Bauteils zu berechnen. Mithilfe von optimierten Bauteilen konn- ten Betriebstemperaturen von mehr als 90 ◦C und Ausgangsleistungen von mehr als 100mW bei einer Betriebstemperatur von 20 ◦C erreicht werden. Im Hinblick auf die Anwendung der Laser in der Absorptionsspektroskopie wurde ab- schließend ein DFB-Konzept, welches zuvor bereits in konventionellen Diodenlasern zur Anwendung kam, erfolgreich auf das ICL - Material übertragen. Dabei kommt ein periodisches Metallgitter zum Einsatz, welches seitlich der geätzten Stege aufge- bracht wird und aufgrund von Verlustkopplung eine longitudinale Mode bevorzugt. Durch den Einsatz von unterschiedlichen Gitterperioden konnten monomodige ICLs basierend auf dem selben Epitaxiematerial in einem spektralen Bereich von mehr als 100nm hergestellt werden. Ein 2.4mm langer DFB- Laser konnte einen Abstimmbe- reich von mehr als 10nm bei Verschiebungsraten von 0.310nm/K und 0.065nm/mA abdecken. Der DFB- ICL zeigte im Dauerstrichbetrieb in einem Temperaturbereich zwischen 10 und 35 ◦C monomodigen Betrieb mit einer Ausgangsleistung von mehre- ren mW. Basierend auf dem in dieser Arbeit gewachsenem Material und dem DFB- Konzept konnte im Rahmen verschiedener Entwicklungsprojekte bereits erfolgreich Absorptionsspektroskopie in einem breiten Spektralbereich des mittleren Infrarot be- trieben werden. N2 - Due to the high sensitivity regarding absorption spectroscopy in the mid infrared spectral range the demand for monolithic, compact and energy efficient laser sourcesin the wavelength window between 3 and 6 μm is steadily increasing. Numerous absorption bands of gases relevant in industrial and medical applications are situated in this window. Utilizing conventional diode lasers this range could not be sufficiently covered, whereas quantum cascade lasers are of limited suitability for portable applications due to their high threshold power. Interband cascade lasers combine the advantage of interband transitions with the possibility of cascading from quantum cascade lasers and can cover a very wide spectral range. The main objective of this work was the optimization of molecular epitaxially grown mid infrared interband cascade lasers based on GaSb substrates for their utilization in gas sensing. This implies the realization of continuous wave operation at room temperature, to achieve as low threshold powers as possible and also the development of a flexible concept that realizes the selection of a single longitudinal mode. Since the quality of epitaxially grown layers is of high importance for the fabrication of high performance devices it was investigated and optimized in various growth series. After the flux ratio between the group -V elements Sb and As, that enables strain compensation in InAs/AlSb superlattices, was found the optimal substrate temperature during growth of these was determined to 450 °C. Using PL - as well as HRXRD- measurements of test samples the optimal substrate temperature during growth of the characteristic W- quantum wells was also set to 450 ◦C. The As - flux during the growth of the InAs layers inside these wells could be identified as a critical parameter as well. The best results could be achieved at an As - flux of (1.2 ± 0.2) × 10−6 torr. Moreover a very high growth homogeneity on the GaSb wafers of 2′′ size could be verified in cooperation with the Wrocław University of Science and Technology. Subsequently to the growth optimizations of the different functional groups of the laser structure various variations based on a published laser design were investigated in order to optimize the laser characteristics. To compare the results 2.0mm long and 150 μm wide broad area lasers were processed and characterized. A significant improvement of the laser characteristics could be achieved due to the implementation of the carrier rebalancing concept inside the active region. A Si -doping concentration of 5.0 × 1018 cm−3 in the inner four InAs - layers of the electron injector lead to a threshold power density as low as 491 W/cm2. This equals a 59% reduction from the value of the reference structure. By conducting cavity length dependent measurements the reason for this improvement could be found in the reduction of the internal losses to a value of only 11.3 cm−1. Furthermore the dependence of different characteristic variables on the number of cascades inside the active region was investigated within the limits of 1 to 12 cascades. As expected from the concept of cascading a monotonic increase of the slope of the current - output power characteristic with the number of cascades and a proportionality between set in voltage and the number of cascades was found. For ICLs with a given waveguide configuration and a wavelength of 3.6 μm the lowest threshold power density of 326 W/cm2 at a temperature of 20 °C was achieved for a four stage ICL. Beyond that a threshold current density of less than 100 A/cm2 could be found for a device with 10 cascades - a record for semiconductor lasers in this wavelength range. Additionally a reduction of the threshold power density in five stage ICLs of 24% could be achieved with the reduction of the doping density in the inner part of the separate confinement layers from 3 × 1017 cm−3 to 4 × 1016 cm−3. The reason for this was also found in a significant reduction of the internal loss. In a further test series the influence of the separate confinement layer - thickness on the spectral and electro - optic properties was investigated. Additionally ICLs were realized with cladding layers made of quaternary Al0.85Ga0.15As0.07Sb0.93 instead of InAs/AlSb - superlattices. For an ICL of this kind a threshold current density of 220 A/cm2 at a wavelength of 3.4 μm could be reached. Based on the before mentioned improvements and design rules from literature several ICLs in the wavelength window between 2.8 and 5.7 μm were fabricated in the framework of different international projects. Comparing these results a clear trend towards an increase in threshold current density with increasing wavelength was found. The characteristic temperature of the processed broad area lasers decreases from 65 K at λ = 3.0 μm to a minimum of 35K in the wavelength region around 4.5 μm and increases again for ICLs with even longer wavelengths. A possible reason for this was found in the arrangement of the valence bands in the W-quantum well. To investigate the capability of continuous wave operation above room temperature, which brings a clear benefit in applications, ridge waveguide lasers with a thick electroplated gold layer for improved heat dissipation were processed. After mounting the lasers on heat sinks the influence of the device length and width on several characteristics was determined. Furthermore an equation was verified which allows predicting the maximum operation temperature in continuous wave operation from the threshold power based characteristic temperature and the thermal resistance of a laser device. Optimized devices could reach a maximum operation temperature in continuous wave mode of more than 90 ◦C and an output power of more than 100 mW at an operation temperature of 20 ◦C. With regard to the application in absorption spectroscopy a DFB concept, which has already been demonstrated in conventional diode lasers, could be successfully adapted for ICLs. The concept is based on a metal grating that is placed on the side of the laser ridge and favours one longitudinal mode due to loss coupling. By utilizing different grating periods single mode ICLs based on the same epitaxial material could be fabricated in a spectral range of more than 100 nm width. A 2.4 mm long DFB - laser could cover a tuning range of more than 10nm with temperature and current tuning rates of 0.310 nm/K and 0.065 nm/mA respectively. The DFB- ICL device showed single mode operation in a temperature range from 10 to 35 °C with an output power of several mW. Based on the epitaxial material grown in this work and the DFB- concept a variety of absorption spectroscopy experiments in the framework of several projects could be carried out in a wide range of the mid infrared spectral region. KW - Halbleiterlaser KW - Interbandkaskadenlaser KW - Infrarotemission Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-169247 ER - TY - THES A1 - Weigold, Lena T1 - Ermittlung des Zusammenhangs zwischen mechanischer Steifigkeit und Wärmetransport über das Festkörpergerüst bei hochporösen Materialien T1 - Correlation between elasticity and heat transport along the solid framework in the case of highly porous materials N2 - Ziel dieser Arbeit ist es, ein verbessertes Verständnis für den Zusammenhang zwischen mechanischer Steifigkeit und Wärmetransport über das Festkörpergerüst bei hochporösen Materialien zu erlangen. Im Fokus dieser Arbeit steht die Fragestellung, wie mechanische Steifigkeit und Wärmeleitfähigkeit bei hochporösen Materialien miteinander zusammenhängen und ob es möglich ist, diese beiden Eigenschaften durch geometrische Modifikationen der Mikrostruktur unabhängig voneinander zu verändern. Die durchgeführten Untersuchungen haben gezeigt, dass ein Großteil der mikrostrukturellen Modifikationen beide Materialeigenschaften beeinflussen und die mechanische Steifigkeit in der Regel eng mit dem Wärmetransport über das Festkörpergerüst verknüpft ist. Es konnte jedoch auch nachgewiesen werden, dass die mechanische Steifigkeit bei hochporösen Materialien nicht eindeutig mit dem Wärmetransport über das Festkörpergerüst zusammenhängt und spezifische mikrostrukturelle Modifikationen einen stärkeren Einfluss auf die mechanische Steifigkeit besitzen, als auf den Wärmetransport über das Festkörpergerüst. Umgekehrt ist diese Aussage nicht ganz so eindeutig. Die theoretische Betrachtung des Zusammenhangs zeigt, dass in die Berechnung der mechanischen Steifigkeit teils andere geometrische Strukturgrößen einfließen, als in die Berechnung des Wärmetransports über das Festkörpergerüst, so dass die mechanische Steifigkeit unabhängig von der Wärmeleitfähigkeit verändert werden kann. Es zeigt sich jedoch auch, dass die meisten strukturellen Veränderungen beide Eigenschaften beeinflussen und die mechanische Steifigkeit aufgrund der Biegedeformation der Netzwerkelemente systematisch stärker auf strukturelle Veränderungen reagiert als die Wärmeleitfähigkeit der Struktur, so dass die mechanische Steifigkeit in der Regel quadratisch mit der Wärmeleitfähigkeit des Festkörpergerüstes skaliert. Mit den Methoden der effective-media-theory lassen sich Grenzen ermitteln, innerhalb derer sich mechanische Steifigkeit und Wärmeleitfähigkeit unabhängig voneinander variieren lassen. Im experimentellen Teil der Arbeit wurden Probenserien von Polyurethan-Schäumen, Polyurea Aerogelen und organisch / anorganischen Hybrid Aerogelen herangezogen, so dass poröse Materialien mit geordneten, voll vernetzten Mikrostrukturen, mit statistisch isotropen, teilvernetzen Mikrostrukturen, sowie Mikrostrukturen mit anisotropen Charakter in die Untersuchung einbezogen werden konnten. Als Struktureigenschaften, die die mechanische Steifigkeit ungewöhnlich stark beeinflussen, konnten die Regelmäßigkeit der Struktur und der Krümmungsradius der Netzwerkelemente sicher identifiziert werden. Alle weiteren strukturellen Veränderungen führen zu dem annähernd quadratischen Zusammenhang. In einem dritten Abschnitt dieser Arbeit wird das vereinfachte Phononendiffusionsmodell herangezogen, um den Zusammenhang zwischen mechanischer Steifigkeit und Wärmetransport über das Festkörpergerüst bei Aerogelen grundlagenphysikalisch zu modellieren. Zur Diskussion werden die experimentell ermittelten Eigenschaften der isotropen Polyurea Aerogele herangezogen und eine qualitative Modellierung ihrer Schwingungszustandsdichten durchgeführt. Es konnte gezeigt werden, dass die Kombination aus Probendichte und Schallgeschwindigkeit, mit der sich die mechanische Steifigkeit berechnen lässt, unter bestimmten Randbedingungen auch die Energie und Transporteigenschaften der Phononen beschreibt, die den Wärmetransport über das Festkörpergerüst bei Aerogelen bestimmen. Die Ergebnisse dieser Arbeit lassen sich zum Beispiel heranziehen, um die Eigenschaften hochporöser Materialien für eine gegebene Anwendung durch mikrostrukturelle Modifikationen optimal zu gestalten. N2 - The objective of this thesis is to gain a fundamental understanding for the correlation between mechanical stiffness and heat transport along the solid framework in highly porous materials. This study focuses on the question, whether the elastic modulus of the structure or the solid phase thermal conductivity can be changed without affecting the other property. The performed investigation has shown that micro-structural modifications usually have an effect on both, the elastic modulus and the solid phase thermal conductivity, respectively and that these properties are strongly correlated in highly porous materials. However, at the physical level, the elastic modulus is not explicitly correlated to the heat transport along the solid framework. It was possible to identify some individual geometrical aspects that have a superior impact on the elastic modulus but only influence the thermal conductivity in a certain degree. Vice versa, geometrical aspects that only affect the heat transport along the solid phase could not be clearly identified. Structural modeling of highly ordered and of statistically isotropic porous materials is considered for a theoretical correlation between mechanical stiffness and heat transport along the solid framework in highly porous materials. Correlation is furthermore derived without taking into account any structural information. Structural modeling shows that different structural parameters are required to calculate the mechanical stiffness and the heat transport along the solid framework of a porous material, which allows for a structural decoupling of these two properties. However, most of the time, a quadratic correlation between elastic modulus and solid phase thermal conductivity is found within the models, because mechanical stiffness systematically reacts more sensitive to structural changes as the network elements are bended under mechanical load. With the help of the effective-media-theory a lower and upper bound can be derived for possible pair-combinations between material stiffness and solid phase thermal conductivity. For the experimental study of this topic polyurethane foams, polyurea aerogels and organic-anorganic hybrid aerogels are chosen as sample systems. Herewith, the study includes materials of regular, fully connected microstructures, isotropic, partly connected microstructures and anisotropic microstructures. Despite substantial structural changes, elastic modulus scales approximately quadratic with the solid phase thermal conductivity in most of the samples series investigated. Merely the overall modification of the structural regularity and the bending of the network elements up to high curvatures verifiably cause a deviation from the quadratic dependency. In a third section it is discussed, if a simplified model of phonon diffusion process can be used to derive a correlation between mechanical stiffness and heat transport in aerogels. For this study, experimentally derived results of polyurea aerogels and the qualitatively derived vibrational density of states of these materials are taken into account. Results show that the sound velocity and the density of the aerogel can be used to calculate both, mechanical stiffness and, meeting certain boundary conditions, also the energy and transport properties of the phonons that are responsible for the heat transport along the solid framework. Results may be used to design a porous material with optimal properties which are required for specific technical applications. KW - Poröser Stoff KW - Wärmeleitfähigkeit KW - Phonon KW - mechanische Steifigkeit KW - Mikrostruktur KW - porös KW - thermal conductivity KW - mechanical stiffness KW - microstructure KW - porous KW - Mikroporosität KW - Steifigkeit KW - Wärmeübertragung KW - Festkörperphysik Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124806 ER - TY - THES A1 - Weigand, Wolfgang T1 - Geometrische Struktur und Morphologie epitaktisch gewachsener ZnSe-Schichtsysteme T1 - Geometric structure and morphology of ZnSe-layersystems N2 - Halbleiterbauelemente sind im täglichen Leben allgegenwärtig und haben in den letzten Jahrzehnten unseren Lebensstil vollkommen verändert.Während diemikro-elektronischen Bauelemente hauptsächlich auf Silizium-Technologie basieren, gewannen Anfang der 90-ziger Jahre Verbindungshalbleiter wie GaAs, GaN, CdHgTe oder ZnSe für opto-elektronische Bauelemente immer stärkere Bedeutung. Besonders der II-VI Halbleiter ZnSe war wegen seiner großen Bandlücke und seiner geringen Versetzungsdichte einer der größten Hoffnungsträger, blau emittierende Laserdioden zu realisieren. Wie sich später zeigte, weisen ZnSe-basierte blaue Laserdioden aber binnen kurzer Zeit eine ausgeprägte Degradation ihrer opto-elektronisch aktiven Schicht auf [Guha97]. Dies führte schließlich dazu, dass sich zur Produktion blau-grün emittierender Laserdioden das konkurrierende Halbleitermaterial GaN durchsetzte [Pearton99] und ZnSe in den Hintergrund gedrängt wurde. In jüngster Zeit aber erlebt das ZnSe Halbleitermaterial in spintronischen Bauelementen eine Renaissance [Fiederling99], und auch in Kombination mit Mg und Fe konnten interessante magnetische Eigenschaften nachgewiesen werden [Marangolo01,Marangolo02]. ZurHerstellung der oben erwähnten opto-elektronischen und spintronischen Schichtstrukturen wird hauptsächlich die Molekular-Strahl-Epitaxie (MBE) eingesetzt. Sie gewährleistet erstens eine geringe Defektdichte und einen hohen Reinheitsgrad der erzeugten Schichtstrukturen. Zweitens können die elektronischen Eigenschaften der so erzeugten Schichtstrukturen durchDotierung gezielt beeinflusstwerden. Für das Wachstum der ZnSe-basierten Schichtsysteme ist zum einen die genutzte Substratfläche entscheidend. Als mögliche Substratkristalle bieten sich Halbleitermaterialien wie GaAs und Germanium an, die gegenüber dem ZnSe-Kristall eine sehr kleine Gitterfehlanpassung aufweisen (< 0.3 %). Zum anderen nimmt die ZnSe Oberfläche eine wichtige Rolle ein, weil an ihr das Wachstum abläuft und ihre mikroskopischen Eigenschaften direkt das Wachstum beeinflussen. Die genauen Mechanismen dieses Wachstumsprozesses sind bis jetzt nur in Ansätzen verstanden (siehe z.B. [Pimpinelli99,Herman97]), weshalb die Wachstumsoptimierung meist auf empirischem Weg erfolgt. Aus diesem Grund besteht ein gesteigertes akademisches Interesse an der Aufklärung der mikroskopischen Eigenschaften der Halbleiteroberflächen. Für die Oberflächen von CdTe- und GaAs-Kristallen wurden diesbezüglich bereits zahlreicheUntersuchungen durchgeführt, die die geometrische und elektronische Struktur und dieMorphologie dieser Oberflächen analysieren.MitHilfe von experimentellen Methoden wie Rastertunnel-Mikroskopie (STM), Photoelektronen-Spektroskopie (PES, ARUPS) und verschiedenen Beugungsmethoden (SXRD,HRXRD und LEED) bzw. theoretischen Berechnungen (DFT) wurde das Verhalten dieser Oberflächen untersucht. Ihren Eigenschaften wird Modell-Charakter zugewiesen, der oft auf andere II-VI und III-V Halbleiteroberflächen angewendet wird. Überraschenderweise ist das Verhalten der ZnSe Oberfläche, obwohl sie so lange im Mittelpunkt der Forschung um den blauen Laser stand, weit weniger gut verstanden. Unter anderemexistieren für die geometrische Struktur der c(2×2)-rekonstruierten ZnSe(001)Wachstumsoberfläche zwei konkurrierende Strukturmodelle, die sich widersprechen. Ziel der nachfolgenden Abhandlung ist es, zuerst die geometrische Struktur und die Morphologie der verschieden rekonstruierten ZnSe(001) Oberflächen zu untersuchen und mit dem Verhalten anderer II-VI Oberflächen zu vergleichen. Dadurch soll festgestellt werden, welche Eigenschaften der II-VI Halbleiteroberflächen Modell-Charakter besitzen, also übertragbar auf andere II-VI Halbleiteroberflächen sind, und welche der Oberflächen-Eigenschaften materialspezifisch sind (siehe Tab. 5.1). Zweitens wird die geometrische Struktur und dieMorphologie der Te-passivierten Ge(001) Oberfläche untersucht. Diese Oberfläche ist wegen ihrer geringen Gitterfehlanpassung bzgl. des ZnSe Kristalls eine erfolgversprechende Substratoberfläche, um das ZnSe-Wachstum auch auf nicht-polaren Halbleiteroberflächen zu etablieren. Zur Untersuchung der geometrischen Struktur bzw. Morphologie der Halbleiteroberflächen wurden die zwei komplementären Methoden SXRD und SPA-LEED eingesetzt. Die oberflächenempfindliche Röntgenbeugung (SXRD) ermöglicht es, die geometrische Struktur, also den genauen atomaren Aufbau der Oberfläche, aufzuklären. Die hochauflösende niederenergetische Elektronenbeugung (SPA-LEED) hingegen liefert Informationen über die Morphologie, also die Gestalt der Oberfläche auf mesoskopischer Größenskala. Diese Untersuchungen werden durch hochauflösende klassische Röntgenbeugung (HRXRD), Rasterkraft-Mikroskopie (AFM), hochauflösender Photoelektronen-Spektroskopie (PES, ARUPS) und Massen-Spektroskopie (QMS) ergänzt. Die vorliegende Arbeit gliedert sich in folgende drei Teile: Zuerst wird in die SXRD und SPA-LEED Methoden eingeführt, mit denen hauptsächlich gearbeitet wurde (Kapitel 2). Anschließend werden die experimentellen Untersuchungen an der Te/Ge(001) Oberfläche und an den verschieden rekonstruierten ZnSe(001) Oberflächen vorgestellt (Kapitel 5 bis 8). Im dritten und letzten Teil werden schließlich die wichtigsten Ergebnisse und Schlussfolgerungen zusammengefasst (Kapitel 9). N2 - The field of II-VI compound semiconductors has attracted considerable interest, due to important progress in the fabrication of electronic and opto-electronic devices. Since interface effects are often important in thin film systems, a good knowledge of the electronic and geometric structure of surfaces and interfaces is indispensable to design optimized devices. For example, to achieve high-quality pseudomorphic growth of II-VI compound thin films on III-V substrates a detailed knowledge about the II-VI/III-V interface and the II-VI surface is essential. An example of recent progress in this field is the c(2×2)-reconstructed ZnSe(001) surface. However, there is still an ongoing discussion concerning the exact geometric structure of the c(2×2)-reconstructed ZnSe(001) surface, which is somewhat surprising, since this system has been extensively investigated in the past and is considered to be a model-system for II-VI MBE growth. Also the hetero-epitaxial growth of compound semiconductors on surfaces such as silicon or germanium is strongly affected by the chemical bonding at the interface. Therefore, in this work the geometric and morphologic structure of the reconstructed ZnSe surface is investigated and compared to other II-VI surfaces. Furthermore, the morphologic structure of the Te covered Ge(001) surface is analyzed to decide whether Te provides better growth conditions for ZnSe films on the Ge(001) surface. The crystallography of surfaces has been investigated primarily by surface x-ray diffraction performed at the Hamburger Synchrotronstrahlungslabor (HASYLAB) at the Deutsches Elektronen-Synchrotron (DESY) inHamburg and themorphology of surfaces by high resolution low energy electron diffraction (SPA-LEED), which was implemented in the MBE-machine of Experimentelle Physik III. Additional experimental techniques used were photoelectron spectroscopy (PES), atomic force microscopy (AFM), quadrupole mass spectroscopy (QMS), and high resolution x-ray diffraction (HRXRD). As shown by SPA-LEED, the Te covered Ge(001) surface is a strained surface, which results in a missing row reconstruction. Large Te covered domains of the surface are interrupted by long parallel rows without adsorbates. This arrangement allows the Te rows to expand laterally into the Te-free rows and lowers the stress of the Te covered Ge(001) surface. This is also achieved by double steps,which also exist on the Te covered Ge(001) surface. By annealing the Te covered Ge(001) surface Te desorbs, and the randomly arranged missing rows form an ordered grating, the period of which increase if the Te coverage is reduced. When the tellurium is completely desorbed, the surface shows the well-known (2×1)-reconstruction of a clean Ge(001) surface. Furthermore, a (113)-faceting of the (001) surface occurs during Te adsorption at higher substrate temperatures. For these reasons, the Te covered Ge(001) surface is not suited as a substrate for the ZnSe growth. However, the stripe pattern of this surface may be adapted as a template for a preferential adsorption of, e.g., organic molecules. Using high-resolution low-energy electron diffraction (SPA-LEED) correlations of neighboring superstructure domains of the ZnSe(001) surface across steps are found. These steps run along the [110]- and [1¯10]-directions at the (2×1)-reconstructed ZnSe(001) surface and formso-called incommensurate domainwalls. This behavior of the ZnSe(001) surface is in contrast to the behavior of the CdTe(001) surface. It may be explained by the different elastic properties of the ZnSe and the CdTe crystal, respectively. At the c(2×2)-reconstructed surface the neighboring superstructure domains are correlated across [100]- and [010]-oriented steps. This is well known from sputtered and annealed ZnSe surfaces by the work of Chen et al. [Chen02]. We show that this is also true for MBE grown ZnSe surfaces and, therefore, the correlations of the superstructure domains are an intrinsic property of the c(2×2)-reconstructed ZnSe(001) surface. The ZnSe(001) surface sublimates at temperatures above 450 ◦C. In contrast to Cd-Te(001), deep cavities arise during sublimation. Since this sublimation temperature is much higher than the growth temperature, sublimation does not affect the growth of ZnSe. Also the ZnSe/GaAs layer-system shows an unexpected morphologic effect. As normal for metal surfaces, above a critical thickness of 100 nm the topmost ZnSe layer relaxes by forming large mosaic domains, which are tilted by 0.2◦ with respect to the macroscopic surface. The misfit of the ZnSe/GaAs interface probably induces this formation of mosaic domains. The geometric structure of the c(2×2)-reconstructed ZnSe(001) surface is studied by surface X-ray diffraction performed under ultra-high vacuum using synchrotron radiation, which reveals the precise atomic geometry. The results are in excellent agreement with the Zn-vacancy model proposed earlier on the basis of density functional theory calculations [Park94]. The Se-vacancy model [Ohtake99b], which challenges this theoretical calculation, can be excluded on the basis of our measurements. The special morphologic properties of the (2×1)-reconstructed ZnSe surface prohibit a precise quantitative analysis of the surface structure. Nevertheless, it was discovered that asymmetrical translated Se-dimers, which are well-known from the Si(001)-(2×1) and Ge(001)-(2×1) surfaces, but unexpected from the theoretical point of view for the ZnSe surface, form on the reconstructed surface. These findings are confirmed by PES-measurements. KW - Zinkselenid KW - Epitaxieschicht KW - Halbleiteroberfläche KW - LEED KW - Röntgenbeugung KW - Oberflächenphysik KW - geometrische Struktur KW - Oberflächenröntgenbeugung KW - hochauflösende Elektronenbeugung KW - II-IV Halbleiter KW - surface science KW - II-VI semiconductor KW - diffraction Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12955 ER - TY - THES A1 - Weigand, Frank T1 - XANES und MEXAFS an magnetischen Übergangsmetalloxiden : Entwicklung eines digitalen Lock-In-XMCD-Experiments mit Phasenschieber T1 - XANES and MEXAFS studies of magnetic transition metal oxides Development of a digital Lock-In XMCD experiment with phase retarder N2 - In dieser Arbeit werden drei Lanthanmanganat-Systeme mittels SQUID-(Superconducting Quantum Interference Device) Magnetometrie und XMCD-(X-ray Magnetic Circular Dich-roism) Messungen an den jeweiligen Absorptionskanten (XANES: X-ray Absorption Near Edge Structure) sowie im kantenfernen Bereich (MEXAFS: Magnetic Extended X-ray Ab-sorption Fine Structure) im Hinblick auf die Klärung ihrer magnetischen (Unter-)Struktur untersucht. Bei Lanthanmanganaten wird sowohl im Verlauf des spingemittelten als auch spinabhängigen Absorptionskoeffizienten an der Mn K Kante immer eine energetisch über 40eV ausgedehnte Doppelstruktur beobachtet. Durch Vergleich mit theoretischen Bandstrukturrechnungen und Messungen an Referenzsystemen lassen sich diese Strukturen auf zwei energetisch getrennte, resonante Übergänge in leere Mn 4p Zustände zurückführen. Die Ursachen liegen in der Kristallstruktur der Lanthanmanganate und damit ihrer Bandstruktur begründet. XMCD-Messungen an den La L2,3 Kanten zeigen, dass dieses Element zur Gesamtmagnetisierung dieser Verbindungen nur ein unerhebliches Moment beiträgt und daher in einer Xenon-ähnlichen Elektronenkonfiguration vorliegt. Durch die interatomare Coulombwechselwirkung der nahezu unbesetzten La 5d Zustände mit den magnetisch aktiven Ionen im Kristall dienen XMCD-Messungen an den La L2,3 Kanten als Sonde für die magnetische Lanthanumgebung. Ähnliches gilt für die entsprechenden MEXAFS. Der proportionale Zusammenhang der Größe der MEXAFS mit dem Spinmoment der Nachbarionen besitzt auch bei den Lanthanmanganat-Systemen mit den stark hybridisierten Elektronen der Mn 3d Schale Gültigkeit. Der Spinmoment-Korrelationskoeffizient aSpin gilt auch hier, was eine weitere Bestätigung des MEXAFS-Modells auch für oxidische Systeme ist. Im dotierten System La1.2Nd0.2Sr1.6Mn2O7 koppelt das Neodymmoment innerhalb einer Doppellage antiferromagnetisch zum Mn-Untergitter. Durch die Neodym-Dotierung am La/Sr-Platz im Kristall ist die ferromagnetische Kopplung der Doppellagen untereinander abge-schwächt und die Rückkehr in die antiferromagnetische Phase nach dem Abschalten des äußeren Magnetfeldes damit erleichtert. Das Mn-Bahnmoment ist von nahezu verschwindender Größe („gequencht“). Das System La1.2Sr1.8Mn2-xRuxO7 zeigt mit zunehmendem Rutheniumgehalt eine Erhöhung der Curie-Temperatur, was bei Ruddlesden-Popper Phasen zum ersten Mal beobachtet wurde. Das Ru-Untergitter und das Mn-Gitter sind zueinander antiparallel gekoppelt. Durch Bestimmung der Valenzen von Mn und Ru wird ein dem Superaustausch ähnliches Kopplungsmodell entworfen, womit der Anstieg in der Curie-Temperatur erklärbar ist. Das neu entwickelte XMCD-Experiment auf Basis eines Phasenschiebers und digitaler Sig-nalaufbereitung durch eine Lock-In Software besitzt ein Signal-Rausch Verhältnis in der Nähe der Photonenstatistik und liefert einen großen Zeit- und Qualitätsgewinn gegenüber Messmethoden mit Magnetfeldwechsel. Auf teure analoge Lock-In Messverstärker kann verzichtet werden. Zukünftig erweitert sich mit diesem Aufbau die für XMCD-Experimente zugängliche Anzahl an Synchrotronstrahlplätzen. Diese Experimente sind jetzt auch mit linear polarisierter Röntgenstrahlung an Wiggler/Undulator Strahlplätzen und zukünftigen XFELs (X-ray Free Electron Laser) durchführbar. N2 - In this work three Lanthanum Manganate systems are investigated in terms of their magnetic (sub) structures. These investigations are done with SQUID- (Superconducting Quantum Interference Device) magnetometry and XMCD- (X-ray Magnetic Circular Dichroism) measurements at the respective absorption edges (XANES: X-ray Absorption Near Edge Structure) as well as in the MEXAFS (Magnetic Extended X-ray Absorption Fine Structure) range. For Lanthanum Manganates at the Mn K edge there is always seen a double peak structure in the shape of the spin dependent and spin averaged absorption coefficient, which is energetically expanded over more than 40eV. These structures are ascribed to two energetic separated, resonant transitions into empty Mn 4p states by comparing with theoretical band structure calculations and measurements of reference systems and are caused in the crystal structure of the Lanthanum Manganates and with it their band structure. XMCD-measurements at the La L2,3 edges show that this element adds only a negligible magnetic moment to the total magnetisation and La is therefore in a Xenon-like electronic configuration. These measurements probe the magnetic neighbourhood of the Lanthanum in the crystal due to the interatomic Coulomb interaction of the almost empty La 5d states with the magnetic active ions like the MEXAFS. The proportionality of the MEXAFS amplitude with the spin-moment of the neighboring ions is even valid here for Lanthanum Manganate systems with their strongly hybridized Mn 3d shell electrons. The validity of the correlation coefficient of the spin-moment aSpin confirms the MEXAFS-model also for oxide systems. In the doped system La1.2Nd0.2Sr1.6Mn2O7 the Neodymium moment couples antiferromagnetically with the Mn-sublattice within a double layer. The ferromagnetic coupling of the double layers is weak among each other due to the Nd doping at the La/Sr crystal position. Therefore the reversion into the antiferromagnetic phase is relieved after switching off the external magnetic field. The orbital moment of Mn is almost vanishing (“quenched”). The system La1.2Sr1.8Mn2-xRuxO7 shows an increasing of the Curie-temperature with an increase of the Ruthenium doping level, observed for the first time for Ruddlesden-Popper phases. The Ru-sublattice is antiparallel coupled to the Mn-sublattice. A superexchange like coupling model is composed through determination of the valences of Mn and Ru, also explaining the increase of the Curie-temperature. A new XMCD-experiment is developed with phase retarder and digital signal processing through Lock-In software with signal to noise ratio nearby photon statistics. This experiment provides a huge benefit in time and quality compared to XMCD-measurement with changing the external magnetic field. Also there is no need of expensive Lock-In analog amplifiers. Now the number of synchrotron beamlines for XMCD-measurements are increased and XMCD-experiments are realizable also at Wiggler/Undulator beamlines with linear polarized radiation and in future at XFEL (X-ray Free Electron Laser). KW - Lanthanoxid KW - Manganate KW - XANES KW - EXAFS KW - Röntgenzirkulardichroismus KW - Perowskite KW - CMR-Systeme KW - Phasenschieber KW - digitaler Lock-In KW - XMCD KW - perovskites KW - CMR-systems KW - phase retarder KW - digital Lock-In Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8849 ER - TY - THES A1 - Weick, Stefan T1 - Retrospektive Bewegungskorrektur zur hochaufgelösten Darstellung der menschlichen Lunge mittels Magnetresonanztomographie T1 - Retrospective Motion Correction for High Resolution Magnetic Resonance Imaging of the Human Lung N2 - Ziel dieser Arbeit war es, das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung mittels der MRT darzustellen. Um trotz der niedrigen Protonendichte der Lunge und der geforderten hohen Auflösung ausreichend Signal für eine verlässliche Diagnostik zu erhalten, sind Aufnahmezeiten von einigen Minuten nötig. Um die Untersuchung für den Patienten angenehmer zu gestalten oder auf Grund der eingeschränkten Fähigkeit eines Atemstopps überhaupt erst zu ermöglichen, war eine Anforderung, die Aufnahmen in freier Atmung durchzuführen. Dadurch entstehen allerdings Bewegungsartefakte, die die Diagnostik stark beeinträchtigen und daher möglichst vermieden werden müssen. Für eine Bewegungskompensation der Daten muss die auftretende Atembewegung detektiert werden. Die Bewegungsdetektion kann durch externe Messgeräte (Atemgurt oder Spirometer) oder durch eine zusätzliche Anregungen erfolgen (konventionelle Navigatoren) erfolgen. Nachteile dieser Methoden bestehen darin, dass die Bewegung während der Atmung nicht direkt verfolgt wird, dass elektronische Messgeräte in die Nähe des Tomographen gebracht werden und das die Patienten zusätzlich vorbereitet und eingeschränkt werden. Des Weiteren erfordert eine zusätzliche Anregung extra Messzeit und kann unter Umständen die Magnetisierung auf unterwünschte Weise beeinflussen. Um die angesprochenen Schwierigkeiten der Bewegungsdetektion zu umgehen, wurden in dieser Arbeit innerhalb einer Anregung einer 3d FLASH-Sequenz sowohl Bilddaten- als auch Navigatordaten aufgenommen. Als Navigator diente dabei das nach der Rephasierung aller bildgebenden Gradienten entstehende Signal (DC Signal). Das DC Signal entspricht dabei der Summe aller Signale, die mit einem bestimmten Spulenelement detektiert werden können. Bewegt sich beispielsweise die Leber bedingt durch die Atmung in den Sensitivitätsbereich eines Spulenelementes, wird ein stärkeres DC Signal detektiert werden. Je nach Positionierung auf dem Körper kann so die Atembewegung mit einzelnen räumlich lokalisierten Spulenelementen nachverfolgt werden. Am DC Signalverlauf des für die Bewegungskorrektur ausgewählten Spulenelementes sind dann periodische Signalschwankungen zu erkennen. Zusätzlich können aus dem Verlauf Expirations- von Inspirationszuständen unterschieden werden, da sich Endexpirationszustände im Regelfall durch eine längere Verweildauer auszeichnen. Grundsätzlich kann das DC Signal vor oder nach der eigentlichen Datenaufnahme innerhalb einer Anregung aufgenommen werden. Auf Grund der kurzen Relaxationszeit T∗2 des Lungengewebes fällt das Signal nach der RF Anregung sehr schnell ab. Um möglichst viel Signal zu erhalten sollten, wie in dieser Arbeit gezeigt wurde, innerhalb einer Anregung zuerst die Bilddaten und danach die Navigatordaten aufgenommen werden. Dieser Ansatz führt zu einer Verkürzung der Echozeit TE um 0.3 ms und damit zu einem SNR Gewinn von etwa 20 %. Gleichzeitig ist das verbleibende Signal nach der Datenakquisition und Rephasierung der bildgebenden Gradienten noch ausreichend um die Atembewegung zu erfassen und somit eine Bewegungskorrektur der Daten (Navigation) zu ermöglichen. Um eine retrospektive Bewegungskorrektur durchführen zu können, müssen Akzeptanzbedingungen (Schwellenwerte) für die Datenauswahl festgelegt werden. Bei der Wahl des Schwellenwertes ist darauf zu achten, dass weder zu wenige noch zu viele Daten akzeptiert werden. Akzeptiert man sehr wenige Daten, zeichnen sich die Rekonstruktionen durch einen scharfen Übergang zwischen Lunge und Diaphragma aus, da man sehr wenig Bewegung in den Rekonstruktionen erlaubt. Gleichzeitig erhöht sich allerdings das Risiko, dass nach der Navigation Linien fehlen. Dies führt zu Einfaltungsartefakten, die in Form von gestörten Bildintensitäten in den Rekonstruktionen zu sehen sind und die diagnostische Aussagekraft einschränken. Um Einfaltungsartefakte zu vermeiden sollte der Schwellenwert so gewählt werden, dass nach der Datenauswahl keine Linien fehlen. Aus dieser Anforderung lässt sich ein maximaler Schwellenwert ableiten. Akzeptiert man dagegen sehr viele Daten, zeichnen sich die Rekonstruktionen durch erhöhtes Signal und das vermehrte Auftreten von Bewegungsartefakten aus. In diesem Fall müsste der Arzt entscheiden, ob Bewegungsartefakte die Diagnostik zu stark beeinflussen. Wählt man den Schwellenwert so, dass weder Linien fehlen noch zu viel Bewegung erlaubt wird, erhält man Rekonstruktionen die sich durch einen scharfen Diaphragmaübergang auszeichnen und in denen noch kleinste Gefäße auch in der Nähe des Diaphragmas deutlich zu erkennen sind. Hierfür haben sich Schwellenwerte, die zu einer Datenakzeptanz von ca. 40 % führen als günstig erwiesen. Um Einfaltungsartefakte auf Grund der retrospektiven Datenauswahl zu verhindern, muss das Bildgebungsvolumen mehrfach abgetastet werden. Dadurch wird gewährleistet, dass für die letztendliche Rekonstruktion ausreichend Daten zur Verfügung stehen, wobei mehrfach akzeptierte Daten gemittelt werden. Dies spielt auf Grund der niedrigen Protonendichte der Lunge eine wesentliche Rolle in der Rekonstruktion hochaufgelöster Lungendatensätze. Weiterhin führt das Mitteln von mehrfach akzeptierten Daten zu einer Unterdrückung der sogenannten Ghost Artefakte, was am Beispiel der Herzbewegung in der Arbeit gezeigt wird. Da die Messungen unter freier Atmung durchgeführt werden und keine zusätzlichen externen Messgeräte angeschlossen werden müssen, stellte die Untersuchung für die Patienten in dieser Arbeit kein Problem dar. Im ersten Teil dieser wurde Arbeit gezeigt, dass sich mit Hilfe des DC Signales als Navigator und einer retrospektiven Datenauswahl das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung von beispielsweise 1.6 x 1.6 x 4 mm3 innerhalb von 13 min. darstellen lässt. Die Anwendbarkeit der vorgestellten Methode zur Bewegungskorrektur wurde neben Probanden auch an Patienten demonstriert. Da wie bereits beschrieben das Bildgebungsvolumen mehrfach abgetastet werden muss, wiederholt sich auch die Abfolge der für die Bildgebung verantwortlichen Gradienten periodisch. Da sich der Atemzyklus aber auch periodisch wiederholt, kann es zu Korrelationen zwischen der Atmung und den wiederholten Messungen kommen. Dies führt dazu, dass auch nach vielen wiederholten Messungen immer noch größere Bereiche fehlender Linien im k-Raum bleiben, was zu Artefakten in den Rekonstruktionen führt. Dies konnte im Falle der konventionellen Bewegungskorrektur in den Gatingmasken, die die Verteilung und Häufigkeit der einzelnen akzeptierten Phasenkodierschritte im k-Raum zeigen, beobachtet werden. Da eine vorsätzliche Unterbrechung der Atemperiodizität (der Patient wird dazu angehalten, seine Atemfrequenz während der Messung absichtlich zu variieren) zur Vermeidung der angesprochenen Korrelationen nicht in Frage kommt, musste die Periodizität in der Datenaufnahme unterbrochen werden. In dieser Arbeit wurde dies durch eine quasizufällige Auswahl von Phasen- und Partitionskodiergradienten erreicht, da Quasizufallszahlen so generiert werden, dass sie unabhängig von ihrer Anzahl einen Raum möglichst gleichförmig ausfüllen. Die quasizufällige Datenaufnahme führt deshalb dazu, das sowohl akzeptierte als auch fehlende Linien nach der Bewegungskorrektur homogen im k-Raum verteilt auftreten. Vergleicht man das auftreten von Ghosting zeichnen sich die quasizufälligen Rekonstruktionen im Vergleich zur konventionellen Datenaufnahme durch eine verbesserte Reduktion von Ghost Artefakten aus. Dies ist auf die homogene Verteilung mehrfach akzeptierter Linien im k-Raum zurückzuführen. Die homogenere Verteilung von fehlenden Linien im k-Raum führt weiterhin zu einer wesentlich stabileren Rekonstruktion fehlender Linien mit parallelen MRT-Verfahren (z.B. iterativem Grappa). Dies wird umso deutlicher je höher der Anteil fehlender Linien im k-Raum wird. Im Falle der konventionellen Datenaufnahme werden die zusammenhängenden Bereiche fehlender Linien immer größer, was eine erfolgreiche Rekonstruktion mit iterativem Grappa unmöglich macht. Im Falle der quasizufälligen Datenaufnahme dagegen können auch Datensätze in denen 40% der Linien fehlen einfaltungsartefaktfrei rekonstruiert werden. Im weiteren Verlauf der Arbeit wurde gezeigt, wie die Stabilität der iterativen Grappa Rekonstruktion im Falle der quasizufälligen Datenaufnahme für eine erhebliche Reduktion der gesamten Messzeit genutzt werden kann. So ist in einer Messzeit von nur 74s die Rekonstruktion eines artefaktfreien und bewegungskorrigierten dreidimensionalen Datensatzes der menschlichen Lunge mit einer Auflösung von 2 x 2 x 5 mm3 möglich. Des Weiteren erlaubt die quasizufällige Datenaufnahme in Kombination mit iterativem Grappa die Rekonstruktion von Datensätzen unterschiedlicher Atemphasen von Inspiration bis Expiration (4D Bildgebung). Nach einer Messzeit von 15min. wurden 19 unterschiedliche Atemzustände rekonstruiert, wobei sich der Anteil der fehlenden Linien zwischen 0 und 20 % lag. Im Falle der konventionellen Datenaufnahme wäre eine wesentlich längere Messzeit nötig gewesen, um ähnliche Ergebnisse zu erhalten. Zum Schluss soll noch ein Ausblick über mögliche Weiterentwicklungen und Anwendungsmöglichkeiten, die sich aus den Erkenntnissen dieser Arbeit ergeben haben, gegeben werden. So könnte das quasizufällige Aufnahmeschema um eine Dichtegewichtung erweitert werden. Hierbei würde der zentrale k-Raum Bereich etwas häufiger als die peripheren Bereiche akquiriert werden. Dadurch sollte die iterative Grappa Rekonstruktion noch stabiler funktionieren und Ghost Artefakte besser reduziert werden. Die Verteilung der Linien sollte allerdings nicht zu inhomogen werden, um größere Lücken im k-Raum zu vermeiden. Darüber hinaus könnte die vorgestellte Methode der Bewegungskompensation auch für die Untersuchung anderer Organe oder Körperteile verwendet werden. Voraussetzung wäre lediglich das Vorhandensein dezidierter Spulenanordnungen, mit denen die Bewegung nachverfolgt werden kann. So ist beispielsweise eine dynamische Bildgebung des frei und aktiv bewegten Knies möglich, wobei zwischen Beugung und Streckung durch die erste Ableitung des zentralen k-Raum Signales unterschieden werden kann. Dies kann zusätzliche Diagnoseinformationen liefern oder für Verlaufskontrollen nach Operationen benutzt werden [15]. Eine Weiterentwicklung mit hohem klinischen Potential könnte die Kombination der in dieser Arbeit vorgestellten retrospektiven Bewegungskorrektur mit einer Multi- Gradienten-Echo Sequenz darstellen. Hierzu musste die bestehende Sequenz lediglich um eine mehrfache Abfolge von Auslesegradienten innerhalb einer Anregung erweitert werden. Dies ermöglicht eine bewegungskorrigierte voxelweise Bestimmung der transversalen Relaxationszeit T∗2 in hoher räumlicher Auflösung. Unter zusätzlicher Sauerstoffgabe kann es zu einer Veränderung von T∗2 kommen, die auf den sogenannten BOLD Effekt (Blood Oxygen Level Dependent) zurückzuführen ist. Aus dieser Änderung könnten Rückschlüsse auf hypoxische Tumorareale gezogen werden. Da diese eine erhöhte Strahlenresistenz aufweisen, könnte auf diese Bereiche innerhalb des Tumors eine erhöhte Strahlendosis appliziert und so möglicherweise Behandlungsmisserfolge reduziert werden. Gleichzeitig kann durch die 4D Bildgebung eine mögliche Tumorbewegung durch die Atmung erfasst und diese Information ebenfalls in der Bestrahlungsplanung benutzt werden. Die Lungen MRT könnte somit um eine hochaufgelöste dreidimensionale funktionelle Bildgebung erweitert werden. N2 - The goal of this work was to depict the whole lung volume by MRI in high spatial resolution. To obtain sufficient signal for a reliable diagnosis despite the inherently low proton density of the lung and the requested high spatial resolution, total acquisition times of a few minutes are mandatory. Simultaneously, the measurements should be performed under free breathing conditions making patient examinations more comfortable or possible for patients with limited breath holding capabilities. However, free breathing leads to motion artifacts which can severely influence the diagnostic value of the images and hence have to be avoided. To compensate for motion the prevalent breathing pattern has to be detected. This can be achieved by external measurement devices such as a respiration belt or a spirometer or by conventional navigator echoes using an additional excitation pulse. Drawbacks of these methods are that the respiratory motion is detected only indirectly, that electronic devices have to be used near the MRI machine and the patients have to be prepared and are strongly restricted. Furthermore, additional excitation pulses will prolong the total acquisition time and may affect the magnetization adversely. To overcome these limitations of motion detection in the present work, the image as well as the navigator data was acquired within one excitation of a FLASH sequence. The resulting central k-space signal (DC signal) after rephasing of all imaging gradients was used as a navigator signal. The DC signal represents the sum of all signals that can be detected with a single receiver coil element. If the liver is for example moving in the sensitivity area of one coil element due to breathing, an increased DC signal will be detected. Depending on their local position on the body the locally confined coil elements are able to track respiratory motion. The time course of the DC signal of the selected coil element for respiratory motion compensation will depict periodic signal variations accordingly. Additionally, respiratory phases of expiration can be distinguished from inspiratory phases because the resting times in end-expiratory phases are usually longer compared to end-inspiratory phases. The DC signal can be acquired either before or after the actual image data acquisition within one excitation. The short T2* of the human lung tissue leads to a rapid signal decay after the excitation. As shown in this thesis, the DC signal should be acquired after the image data within one excitation. This approach allows for echo time (TE) reduction of 0.3 ms leading to a signal benefit of approximately 20 %. Simultaneously, the remaining signal after image data acquisition and rephasing of all imaging gradients is still sufficient to track respiratory motion and can therefore be used for motion compensation of the acquired data. In order to compensate for motion retrospectively, threshold values for data acceptance have to be defined. Setting the threshold value, neither too less nor too much data should be accepted. Accepting very few data leads to sharp transition between the lung and the diaphragm because not much motion is allowed in the reconstruction process. On the other hand, disturbed signal intensity can be observed because of under-sampling artifacts due to missing lines after gating. These artifacts can restrict the diagnostic value of the reconstructions. Therefore, the selected threshold value should lead to a fully sampled k-space after gating. This requirement can be used to define the maximum threshold value for data acceptance. On the contrary, accepting very much data leads to higher signal intensity but also to more distinctive motion artifacts. In this case, the physician has to decide whether the motion artifacts affect his diagnosis too much. A moderate threshold value leads to a fully sampled k-space as well as good motion artifact compensation. This results in reconstructions that are characterized by a sharp depiction of small vessels even near the diaphragm. For this, threshold values leading to a data acceptance of about 40 % turned out to be beneficial. To avoid under-sampling artifacts because of retrospective gating, the imaging volume has to be acquired several times. This ensures that enough data is available for the final reconstruction whereas multiple accepted data is averaged. Averaging is essential for the reconstruction of high resolution data sets because of the inherently low proton density of the lung. Furthermore it leads to the reduction of ghost artifacts as is shown using the example of heart motion in this work. As no external measurement devices were used and the data was acquired under free breathing conditions the examinations posed no problem for the patients within this work. It was shown so far that the DC signal in combination with retrospective gating can be used to reconstruct high resolution 3d lung data sets with a resolution of 1.6 x 1.6 x 4 mm3 within 13 min., for instance. The applicability of the presented method for motion compensation was shown for volunteers as well as patients. Since as already described the imaging volume must be acquired several times, the series of gradients for spatial encoding are repeated periodically. As the respiratory cycle is periodically as well, correlations between the repeated measurements and the breathing cycle can occur. Therefore, even after many repeated measurements large areas of missing k-space lines can remain, leading to artifacts in the reconstructions. This can be observed in the gating masks, showing the distribution of accepted and missing lines in k-space, in case of conventional motion compensation used in this work so far. To avoid the aforementioned correlations, the periodicity in the repeated acquisitions has to be interrupted because of suspending the periodic breathing pattern of patients deliberately would be a serious intervention and is therefore ineligible. This was accomplished by a quasi-random selection of the phase and partition encoding gradients as quasi-random numbers are generated to fill the space as uniformly as possible regardless of their number. Therefore, accepted lines as well as missing lines are uniformly distributed in k-space after retrospective gating. A more uniform distribution of multiple accepted k-space lines in case of quasirandom sampling leads to an improved reduction of Ghost-Artifacts compared to conventional sampling. Furthermore, the more uniform distribution of missing kspace lines leads a considerably more stable reconstruction of missing lines using parallel imaging techniques (as iterative Grappa for example). This is getting more distinct the higher the proportion of missing k-space lines is. The contiguous areas of missing k-space lines are becoming increasingly large in case of conventional sampling, making a successful reconstruction using iterative Grappa impossible. In contrast, quasi-random sampling enables for the successful reconstruction of artifact free images even when 40 % of the acquired lines were missing after retrospective gating. In addition, the stability of the iterative GRAPPA reconstructions in case of quasirandom sampling allows for a substantial reduction of the total acquisition time. Thus, an artifact free motion compensated data set of 2 x 2 x 5 mm3 resolution could be reconstructed for a measurement time of only 74s. Furthermore, quasi-random sampling in combination with iterative Grappa enables for the reconstruction of data sets of different respiratory phases from inspiration to expiration (4d imaging). Accordingly, 19 different respiratory phases could be reconstructed after 15min of data acquisition. The percentage of missing lines was between 0 and 20 %. Hence, in case of conventional sampling a considerably longer measurement time would have been required to achieve similar results. KW - Kernspintomografie KW - Retrospektive Bewegungskorrektur KW - Magnetresonanztomographie KW - Lungenbildbgebung KW - freie Atmung KW - Retrospective Motion Compensation KW - DC-Gating KW - Lung Imaging KW - free breathing KW - Lunge Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124084 ER - TY - THES A1 - Weber, Stefan T1 - Simulation Studies on the New Small Wheel Shielding of the ATLAS Experiment and Design and Construction of a Test Facility for Gaseous Detectors T1 - Simulationsstudien zur New Small Wheel Abschirmung des ATLAS Experiments und Entwurf und Konstruktion eines Teststandes für Gasdetektoren N2 - In this thesis two main projects are presented, both aiming at the overall goal of particle detector development. In the first part of the thesis detailed shielding studies are discussed, focused on the shielding section of the planned New Small Wheel as part of the ATLAS detector upgrade. Those studies supported the discussions within the upgrade community and decisions made on the final design of the New Small Wheel. The second part of the thesis covers the design, construction and functional demonstration of a test facility for gaseous detectors at the University of Würzburg. Additional studies on the trigger system of the facility are presented. Especially the precision and reliability of reference timing signals were investigated. N2 - In dieser Arbeit werden zwei Projekte vorgestellt, welche beide das gemeinsame Ziel der Entwicklung von Teilchendetektoren verfolgen. Im ersten Teil der Arbeit werden ausführliche Simulationsstudien zur Abschirmung behandelt, die sich auf die Abschirmungsbereiche des geplanten New Small Wheels als Teil der ATLAS-Detektor Verbesserungen konzentrieren. Diese Studien unterstützten die Diskussionen innerhalb der Upgrade-Gemeinschaft und Entscheidungen, welche für die endgültige Kostruktionsplanung des New Small Wheels getroffen wurden. Der zweite Teil der Arbeit umfasst die Konstruktion, den Aufbau sowie den Funktionsnachweis eines Teststandes für Gasdetektoren an der Universität Würzburg. Ebenfalls werden Studien über das Triggersystems des Teststandes dargestellt. Insbesondere wurden die Präzision und Verlässlichkeit von Referenzzeitsignalen untersucht. KW - Teilchendetektor KW - Abschirmung KW - Simulation KW - test facility KW - New Small Wheel KW - Teststand KW - Gasionisationsdetektor KW - European Organization for Nuclear Research. ATLAS Collaboration KW - Computersimulation Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-133084 ER - TY - THES A1 - Weber, Manuel T1 - Action-based quantum Monte Carlo approach to fermion-boson models T1 - Wirkungsbasierte Quanten-Monte-Carlo-Methoden für Fermion-Boson-Modelle N2 - This work deals with the development and application of novel quantum Monte Carlo methods to simulate fermion-boson models. Our developments are based on the path-integral formalism, where the bosonic degrees of freedom are integrated out exactly to obtain a retarded fermionic interaction. We give an overview of three methods that can be used to simulate retarded interactions. In particular, we develop a novel quantum Monte Carlo method with global directed-loop updates that solves the autocorrelation problem of previous approaches and scales linearly with system size. We demonstrate its efficiency for the Peierls transition in the Holstein model and discuss extensions to other fermion-boson models as well as spin-boson models. Furthermore, we show how with the help of generating functionals bosonic observables can be recovered directly from the Monte Carlo configurations. This includes estimators for the boson propagator, the fidelity susceptibility, and the specific heat of the Holstein model. The algorithmic developments of this work allow us to study the specific heat of the spinless Holstein model covering its entire parameter range. Its key features are explained from the single-particle spectral functions of electrons and phonons. In the adiabatic limit, the spectral properties are calculated exactly as a function of temperature using a classical Monte Carlo method and compared to results for the Su-Schrieffer-Heeger model. N2 - Die vorliegende Arbeit beschäftigt sich mit der Entwicklung und Anwendung neuer Quanten-Monte-Carlo-Methoden zur Simulation von Fermion-Boson-Modellen. Grundlage für unsere Entwicklungen ist der Pfadintegralformalismus, in dem das exakte Ausintegrieren der bosonischen Freiheitsgrade zu einer retardierten fermionischen Wechselwirkung führt. Wir geben einen Überblick über drei Methoden, die für die Simulation retardierter Wechselwirkungen geeignet sind. Insbesondere entwickeln wir eine neue Quanten-Monte-Carlo-Methode mit globalen Updates, die das Autokorrelationsproblem früherer Ansätze löst und linear in der Systemgröße skaliert. Wir demonstrieren die Effizienz dieser Methode am Beispiel des Peierls-Übergangs im Holstein-Modell und diskutieren Erweiterungen auf andere Fermion-Boson-Modelle sowie Spin-Boson-Modelle. Des Weiteren zeigen wir, wie mithilfe erzeugender Funktionale bosonische Observablen direkt aus den Monte-Carlo-Konfigurationen berechnet werden können. Dies beinhaltet unter anderem den Boson-Propagator und die spezifische Wärme des Holstein-Modells. Die methodischen Entwicklungen dieser Arbeit erlauben es uns, die spezifische Wärme des spinlosen Holstein-Modells in seinem gesamten Parameterbereich zu untersuchen. Ihre wesentlichen Merkmale werden mithilfe der Einteilchenspektralfunktionen von Elektronen und Phononen erklärt. Im adiabatischen Grenzfall verwenden wir eine klassische Monte-Carlo-Methode, um die Temperaturabhängigkeit der Spektralfunktionen exakt zu berechnen, und vergleichen unsere Ergebnisse für das Holstein-Modell mit Resultaten für das Su-Schrieffer-Heeger-Modell. KW - Monte-Carlo-Simulation KW - Elektron-Phonon-Wechselwirkung KW - Peierls-Übergang KW - Thermodynamik KW - Pfadintegral KW - quantum Monte Carlo KW - Holstein model KW - specific heat KW - one-dimensional systems KW - Quanten-Monte-Carlo KW - Holstein-Modell KW - Spezifische Wärme KW - eindimensionale Systeme Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-157643 ER - TY - THES A1 - Weber, Daniel T1 - Morphologische und funktionelle MRT-Infarktcharakterisierung und Entwicklung einer diffusionsgewichteten MRT-Methode T1 - Morphological and functional MRI infarct characterization and development of a diffusion-weighted MRI method N2 - Diffusionstensorbildgebung im Vergleich zu anderen Parametermethoden für die Infarktcharakterisierung Ziel dieses Teils der Arbeit war die Klärung der Frage, welches Potential verschiedene MR-Parametersequenzen bei der Charakterisierung eines myokardialen Infarkts sowohl im akuten als auch im chronischen Fall haben. Dazu wurde eine Studie mit akut und chronisch infarzierten Rattenherzen durchgeführt. Untersucht wurden die Parameter T1, T2 und T2* sowie die aus der Diffusionstensorbildgebung berechneten Parameter ADC, FA, cs, cp und cl . Es zeigte sich, dass es kein Analogon zum bei einer cerebralen Ischämie bekannten Mismatch-Konzept gibt. Weder im akuten noch im chronischen war Fall eine ausgewiesene Differenz im diagnostizierten Infarktareal zwischen verschiedenen Sequenzen feststellbar. Alles in allem eignen sich zur detaillierten Charakterisierung der Infarktnarbe am besten eine T2*- oder eine Diffusionstensorsequenz. Die T2*-Sequenz liefert optisch das aufschlussreichere Bild, die aufwendigere Diffusionstensorsequenz dagegen bietet aufgrund der vielfachen Darstellungsmöglichkeiten im Postprocessing ein Mehr an Information und zeigt dazu eine Veränderung der Narbe im Zeitverlauf. Oxygenierungsmessung am Mäuseherz in vivo Die Charakterisierung einer Infarktnarbe kann auch über die Darstellung morphologischer Strukturen hinaus erfolgen. Die Oxygenierung ist ein komplexer Parameter, der funktionelle Auskunft über die Vaskularisierung und Viabilität des Gewebes geben kann. Zugang zu diesem Parameter erhält man über T2*-Messungen, da der Parameter T2* sensitiv auf chemisch gebundenen Sauerstoff reagiert. Hier wurden der Einfluss von reiner Sauerstoffatmung im Gegensatz zu normaler Raumluftatmung auf die Oxygenierung bei gesunden und infarzierten Mäusen untersucht. Die Messungen wurden trotz der Schwierigkeiten, die durch die Bewegung durch Atmung und Herzschlag entstehen, in vivo bei 17,6 Tesla implementiert und durchgeführt. Die Auflösung war ausreichend, um auch nach Infarkt extrem ausgedünnte Myokardwände gut auflösen und charakterisieren zu können. Der Effekt auf das Oxygenierungslevel ist stark unterschiedlich zwischen normalen und infarzierten Herzen, woraus auf eine noch nicht weit fortgeschrittene Revaskularisierung der Narbe eine Woche nach Infarzierung geschlossen werden kann. Die Methode wurde darüber hinaus an einem 7,0 Tesla-Magneten zur Verwendung an Ratten implementiert und auf das im Gegensatz zur Maus veränderte Atmungsverhalten der Ratte angepasst. Zum einen kann dadurch der Einfluss des hohen Magnetfeldes auf die Oxygenierungsmessung untersucht werden, zum anderen ist das Herz als zu untersuchendes Objekt bei der Ratte größer. Diffusionswichtung mittels Hole-Burning Die in dieser Arbeit zur Charakterisierung des Herzens verwendete Diffusionsmethode kann im Grenzfall von kurzen T2-Relaxationszeiten an ihre Grenzen stoßen: Bei den verwendeten starken Magnetfeldern klingt das messbare Signal aufgrund der Relaxationszeit T2 oft sehr schnell ab. Daher wurde eine Methode entwickelt, die einen völlig neuen Ansatz zur diffusionsgewichteten Bildgebung verfolgt, bei dem die Informationen über die Diffusion unabhängig von der limitierenden T2-Zeit gewonnen werden können. Die sog. Hole-Burning-Diffusionssequenz verwendet in einem Vorexperiment lediglich die Longitudinalmagnetisierung zur Diffusionswichtung. Das Signal wird dann mit einer schnellen Auslesesequenz akquiriert. Bei der Präparation werden zunächst auf Subvoxel-Niveau Streifen "gebrannt", d.h. die Magnetisierung wird dort gesättigt. Bis zur nächsten Sättigung ist das Verhalten der Magnetisierung abhängig von der T1-Relaxation in diesem Bereich und vom Diffusionsverhalten. Durch rasches Wiederholen des selektiven Pulszugs wird schließlich eine Gleichgewichtsmagnetisierung erreicht, die von der Diffusionskonstanten D und der T1-Relaxationszeit abhängt. Im Rahmen dieser Arbeit wurden die Abhängigkeiten verschiedener Sequenzparameter untersucht und diese mittels Simulationen optimiert. Außerdem wurde die Sequenz an einem Scanner implementiert und erste Experimente damit durchgeführt. Mit Hilfe von Simulationen konnten dazu Lookup-Tabellen generiert werden, mit denen in bestimmten Bereichen (insbesondere bei nicht zu kurzen T1-Relaxationszeiten) sowohl die Diffusionskonstante D als auch die T1-Relaxationszeit quantifiziert werden konnte. N2 - Diffusion tensor imaging for the characterization of myocardial infarction in comparison to other methods The aim of this part of this work was to evaluate the potential of different MR sequences for the characterization of myocardial infarction in both the acute and chronic case. Therefore a study of acute as well as chronic infarcted rat hearts was performed, and the parameters T1, T2, T2* and the parameters ADC, FA, cs, cp and cl calculated from the diffusion tensor images were investigated. It turned out that there is no equivalent to the ischemia. Neither in the acute nor in the chronic case, a notably difference inside the affected area was detectable between different sequences. All in all, for detailed characterization of the infarct scar a T2* or a diffusion tensor sequence are most suitable. The T2* sequence provides a more informative visual image, whereas the more time-consuming diffusion tensor sequence provides a surplus of information due to the multiple display options in post-processing and shows the remodelling of the scar tissue over time. Oxygen level measurements in mouse hearts in vivo The characterization of an infarct scar can also go beyond the representation of morphological structure. The oxygenation is a complex parameter that can provide functional information of the vascularization and viability of the tissue. Access to this parameter is obtained by T2*-measurements, as the parameter T2* is sensitive to chemically bound oxygen. The influence of pure oxygen breathing in contrast to normal room air breathing on the oxygenation level in healthy and infarcted mice have been explored. Despite the difficulties caused by the movement due to respiration and heartbeat the measurements were implemented and carried out at 17.6 Tesla in vivo. The resolution was sufficient to resolve and investigate extremely thinned heart walls after infarction. The effect on the oxygenation level varies considerably between normal and infarcted hearts; that may be caused by a not yet advanced revascularization of the scar. In addition, the method was implemented to a 7.0 Tesla magnet for use in rats and adapted to the respiration of rats, which is different to the respiration of mice. The first reason was that the influence of the higher magnetic field on the measurement of the oxygenation level could be examined. Second, the heart as the examined object is larger in rats. Diffusion weighting using hole burning The MR diffusion method used in this work for the characterization of myocardial infarctions could be limited by extremely short T2 relaxation times. With the strong magnetic fields used here the measurable signal decays very fast due to the relaxation time T2. Therefore, a method for a completely new approach to diffusion-weighted imaging was developed, where the diffusion weighting can be obainted without being limited by the time constant T2. The so-called hole-burning diffusion sequence uses only the longitudinal magnetization for the diffusion weighting in a preliminary experiment. The signal is then acquired with a fast read-out sequence. During the preparation stripes will be "burned" into the magnetization on a subvoxel level, i.e. the magnetization is saturated there. Until the next saturation pulse the behavior of the magnetization depends first on the T1 relaxation time in this area and second on the diffusion. By rapidly repeating the selective pulse train a steady state magnetization dependend on the diffusion constant D and the T1 relaxation time is reached. In this work the dependencies between different sequence parameters were investigated and optimized using simulations. In addition, the sequence was implemented on a MR scanner and first experiments were carried out. With simulated lookup-tables we were able to quantify both the diffusion coefficient D and the T1 relaxation time in the case of not too short relaxation times T1. KW - Kernspintomografie KW - Infarkt KW - MRI KW - infarct KW - characterization KW - diffusion KW - hole-burning KW - NMR-Tomographie KW - Anisotrope Diffusion KW - Diffusion KW - Spektrales Lochbrennen KW - Herzinfarkt Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-71157 ER - TY - THES A1 - Weber, Christian T1 - Electrochemical Energy Storage: Carbon Xerogel-Manganese Oxide Composites as Supercapacitor Electrode Materials T1 - Elektrochemische Energiespeicher: Kohlenstoff Xerogel-Manganoxid Komposite als Elektrodenmaterial für Superkondensatoren N2 - Electrochemical double layer capacitors (EDLC), most commonly referred to as “supercapacitors”, have gained increasing scientific and commercial interest in recent years. Purely electrostatic charge storage processes allow charge- and discharge cycles in the second-time scale, exhibiting a theoretical capacitance in the order of 100 F per gram of electrode material, thereby providing efficient recuperation devices for electromechanical processes, for example. Introducing electrochemically active materials such as manganese oxides into the supercapacitor electrode, allows to combine the double-layer storage with a battery-like storage process, leading to capacitance that can be up to two orders of magnitude larger than those in EDLC. In the present work, an electroless deposition approach of manganese oxide on a carbon scaffold is adapted and further investigated. The carbon material is derived from an organic xerogel, which in turn is prepared via a sol-gel process, allowing tailoring of the structural properties of the carbon, making it an ideal model system to study the relation between morphology and electrochemical performance in the carbon-manganese oxide hybrid electrode. In the first part of this thesis, a variation of manganese oxide deposition time at a low concentration of precursor solution is analyzed. Mass uptakes reach up to 58 wt.%, leading to an increase of volumetric capacitance by a factor 5, however reducing the dynamic performance of the electrode. The structural characterization gives hints on the deposition location of the active material either in the intra-particular pores of the carbon backbone or on the enveloping surface area of the particles forming the backbone. In order to comprehensively answer the question of the location of the active material within the hybrid electrode, the particle size of the carbon backbone and therefore the enveloping surface area of the carbon particles was varied. For samples with high mass uptakes, scanning electron microscopy (SEM) images show a layer thickness of 27 nm of active material around the carbon particles. In order to quantitatively investigate this layer morphology, even for low mass uptakes where no layer is visible in SEM images, a model interpreting data from anomalous small angle X-ray scattering (ASAXS) measurements was developed. The results confirm the presence of a layer around the carbon particles, exhibiting a layer thickness ranging from 3 to 26 nm. From an electrochemical point of view, carbon backbones with a large enveloping surface area will lead to high mass uptakes in the electroless deposition process and therefore lead to high capacitance of the electrode. However, for future application, electrodeposition approaches should be investigated in detail, since no deposits will form on the interface between carbon backbone and current collector, leading to a better dynamic performance of the hybrid electrode. Furthermore, the ASAXS-method should be promoted and applied on other material systems, since this technique allows to draw important conclusions and allows to deduce integral and quantitative information towards a rational design of high performance electrodes. N2 - In den letzten Jahren haben elektrochemische Doppelschichtkondensatoren, meist als “Supercaps” bezeichnet, wachsendes wissenschaftliches und kommerzielles Interesse erfahren. Rein elektrostatische Ladungsspeicherungsprozesse erlauben Lade- und Entladezyklen im Sekundenregime, bei einer theoretischen Kapazität in der Größenordnung von 100 Farad pro Gramm Elektrodenmaterial. Damit steht beispielsweise ein ideales Bauteil zur Energierekuperation in elektromechanischen Prozessen zur Verfügung. Die Verbindung der Doppelschichtelektrode mit elektrochemisch aktiven Materialien, wie zum Beispiel Manganoxiden, erlaubt eine Kombination der elektrostatischen Ladungsspeicherung mit batterieähnlichen Ladungsspeicherungsprozessen. Dies führt zu Kapazitätswerten, die bis zu zwei Größenordnungen über den Kapazitätswerten im Doppelschichtkondensator liegen können. In der vorliegenden Arbeit wurde ein nasschemischer Abscheidungsprozess für die Deposition von Manganoxid auf einem Kohlenstoffgerüst angewendet und weitergehend untersucht. Das Kohlenstoffmaterial wurde aus einem organischem Xerogel hergestellt, welches wiederum durch einen Sol-Gel Prozess dargestellt wurde. Diese Vorgehensweise erlaubt eine gezielte Beeinflussung der strukturellen Eigenschaften des Kohlenstoffes. Dadurch wird das Material zum idealen Modellsystem, um den Einfluss der Morphologie auf die elektrochemischen Eigenschaften der Kohlenstoff-Manganoxid Hybridelektrode zu untersuchen. Im ersten Teil der Arbeit wurde die Abscheidungsdauer des Manganoxids bei einer niedrigen Ausgangskonzentration in der Vorstufe systematisch variiert und die resultierenden Elektroden analysiert. Die MnO2 Massenaufnahme erreichte bis zu 58 wt.%, was zu einer Steigerung der volumetrischen Kapazität um einen Faktor 5 führte. Der Preis für diese Steigerung liegt jedoch in einer Reduktion der Lade- bzw. Entladegeschwindigkeit. Die strukturelle Charakterisierung der Hybridelektroden deutet auf eine Abscheidung des MnO2 in den intrapartikulären Poren der Kohlenstoffpartikel oder auf deren einhüllenden Oberfläche hin. Um den Abscheidungsort des aktiven Materials innerhalb der Hybridelektrode eindeutig zu bestimmen, wurde die Größe der Kohlenstoffpartikel und damit die externe Oberfläche des Kohlenstoffgerüstes systematisch variiert. Aufnahmen mittels Rasterelektronenmikroskopie (REM) zeigen eine Schicht von MnO2 um die Kohlenstoffpartikel mit einer Dicke von bis zu 27 nm für Proben mit Massenzuwächsen von bis zu 130 %. Um die Schichtdicke auch für geringe Massenaufnahmen, bei denen im REM keine Schicht erkennbar ist, quantitativ untersuchen zu können, wurde ein Modell zur Analyse von anomaler Röntgenkleinwinkelstreuung (ASAXS) entwickelt. Die Ergebnisse bestätigen die Existenz einer Schicht um die Kohlenstoffpartikel, deren Dicke zwischen 3 und 26 nm liegt. Aus elektrochemischer Sicht wird ein Kohlenstoffgerüst mit großer einhüllender Oberfläche zu einer großen Massenaufnahme im nasschemischen Abscheidungsprozess und damit zu hohen Kapazitätswerten führen. Für eine zukünftige Anwendung sollten jedoch auch elektrochemische Abscheidungsprozesse genau untersucht werden, da bei dieser Methode kein Material auf der Kontaktfläche zwischen Stromabnehmer und Elektrode abgeschieden wird. Dadurch ist eine Verbesserung der elektrochemischen Performance der Hybridelektrode zu erwarten. Weiterhin sollte die ASAXS-Methode weiterentwickelt und auf andere Materialsysteme angewendet werden, da diese Technik wichtige Schlüsse erlaubt, sowie die Bestimmung integraler und quantitativer Information, die zu gezieltem Design von hocheffizienten Elektroden führen wird. KW - Superkondensator KW - Electrochemical energy storage KW - ASAXS KW - Supercapacitor KW - Energiespeicher KW - Experimental physics Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-130748 ER - TY - THES A1 - Wang, Tungte T1 - Anatomische und funktionelle Magnetresonanztomographie der menschlichen Lunge T1 - Anatomical and Functional 1H Magnetic Resonance Imaging of the Human Lung N2 - Zur Beurteilung der Lungenanatomie wurde das MT-STIR-Verfahren vorgestellt. Es wurde gezeigt, dass das MT-STIR-Verfahren das störende Signal des umgebenden Muskelgewebes effektiv unterdrückt und damit die Visualisierung des Lungenparenchyms verbessert. Im Vergleich zu konventionellen anatomischen 1H-MR-Verfahren wie IR- und MIR-Verfahren erhöht das MT-STIR-Verfahren das Signal-zu-Rausch-Verhältnis (SNR) des Lungenparenchyms signifikant und vermeidet den Signalausfall des Lungenparenchyms aufgrund der pathologischen Verkürzung der Lungen-T1-Relaxationszeit auf ca. 900 ms wie bei Patienten mit Mukoviszidose (CF), so dass sowohl große Lungenperfusionsdefekte in Patienten mit CF als auch kleine ungefährliche Lungenentzündungen in „gesunden“ Probanden durch das MT-STIR-Verfahren gut dargestellt werden können. Für die indirekte, aber quantitative Beurteilung der Lungenventilation wurde die oben genannte schnelle quantitative Lungen-T1-Mapping-Technik während der Inhalation eines Atemgasgemisches mit verschiedenen O2-Konzentrationen (21%, 40%, 60%, 80% und 100%) eingesetzt. Dabei ist im Blut physikalisch gelöster Sauerstoff leicht paramagnetisch und dient als Blut-T1-verkürzendes MR-Kontrastmittel (KM). In der Lunge ist das Blut die Hauptquelle des freien Wassers, so dass Lungen-T1-Werte nach dem Zwei-Kompartimente-Schnellaustausch-Modell der Lungen-T1-Relaxationszeit durch den Blut-T1-Wert beeinflusst werden. Die zugehörige Theorie, ein O2-gestütztes Lungen-T1-Modell, wurde aus der Lungenphysiologie und den T1-Relaxationsmechanismen hergeleitet und zeigt, dass bei Probanden die Lungen-T1-Verkürzung von 21% O2 zu 100% O2 ca. 11% beträgt und die Beziehung zwischen dem Lungen-R1 (= 1/T1)-Wert und der inhalierten O2-Konzentration linear mit einer Steigung von 0,12 1/s und einem R1-Achsenabschnitt von 0,70 1/s ist. Die Steigung wurde im Rahmen dieser Doktorarbeit als oxygen transfer function (OTF) definiert und ist vom gasaustauschbestimmenden Ventilations-Perfusions- und Diffusions-Perfusions-Verhältnis abhängig, so dass sie praktisch ein Maß für den pulmonalen Gasaustausch darstellt. Experimentell wurde gezeigt, dass Lungen-T1-Werte bei 100% O2 um 10% kürzer als bei 21% O2 sind, was gut mit dem O2-gestützten Lungen-T1-Modell übereinstimmt. Weiterhin wurde die OTF dadurch bestimmt, dass die gemessenen Lungen-R1-Werte gegen die inhalierte O2-Konzentration aufgetragen wurden und eine Gerade an die Messpunkte angepasst wurde. Gesundes Lungenparenchym von Probanden und gut perfundiertes Lungenparenchym von Patienten mit CF zeigten OTF-Werte zwischen 0,10 und 0,14 1/s, R1-Achsenabschnitte zwischen 0,70 und 0,80 1/s und ausgezeichnete Korrelationskoeffizienten von annähernd 1,00, was mit dem O2-gestützten Lungen-T1-Modell übereinstimmt. Schlecht perfundiertes Lungenparenchym von Patienten mit CF zeigte eindeutig erniedrigte OTF-Werte, erhöhte R1-Achsenabschnitte und schlechte Korrelationskoeffizienten. Das O2-gestützte Lungen-T1-Mapping-Verfahren zeigt eine hohe Reproduzierbarkeit. Zur Beurteilung der Lungenperfusion wurde eine quantitative Perfusionsmapping-Technik mittels Protonen-Spin-Labeling, ohne Verwendung eines intravenösen Kontrastmittels wie Gadolinium (Gd)-DTPA, vorgestellt. Aus einer nicht-schichtselektiven (globalen) T1-Map und einer schichtselektiven T1-Map derselben Lungenschicht, die jeweils mit der oben genannten schnellen quantitativen Lungen-T1-Mapping-Technik akquiriert wurde, wurde eine Perfusionamap berechnet, wobei jedes Pixel in der Perfusionsmap eine Perfusionsrate in Einheiten von m/100g/min hat. Es wurde demonstriert, dass die hintere coronale Lungenschicht eine höhere Perfusionsrate als die vordere coronale Lungenschicht desselben Probanden hatte, als er in Rückenlage gemessen wurde, was den Gravitationseffekt auf die Lungenperfusion bestätigt. Die berechneten Perfusionsraten des gut perfundierten Lungenparenchyms von Probanden und von Patienten mit CF lagen zwischen 400 und 600 m/100g/min, die gut mit dem Literaturwert übereinstimmen. Die berechneten Perfusionsraten des schlecht perfundierten Lungenparenchyms von Patienten mit CF waren niedriger als 200 m/100g/min. Die Spin-Labeling-Technik zeigte eine hohe Reproduzierbarkeit und niedrige relative Fehler der berechneten Perfusionsraten. N2 - The purpose of this doctoral thesis is to develop noninvasive and clinically feasible methods for assessment of pulmonary anatomy, pulmonary function and cardiac shunts in the human using proton magnetic resonance imaging (1H MRI). All imaging experiments were performed on a commercial 1.5-T whole-body MR scanner. In Chapter 2, an efficient tissue suppression technique is presented which allows one to significantly enhance lung parenchyma visibility. A short inversion time inversion recovery (STIR) experiment combined with a magnetization transfer (MT) experiment was used for magnetization preparation in order to suppress the signal from muscle. A half-Fourier single-shot turbo spin-echo (HASTE) sequence was used as an acquisition module. This approach was used to perform lung anatomical imaging in healthy volunteers and patients with cystic fibrosis (CF). The results obtained demonstrate that with MT-STIR approach high quality human lung images can be obtained and that this approach has the potential for the evaluation of lung pathologies. In Chapter 3, a rapid and robust technique for quantitative T1 mapping of the human lung using an IR SnapshotFLASH sequence is presented. Based on a series of SnapshotFLASH images acquired after a single inversion pulse, high quality and quantitative T1 parameter maps acquired were obtained in under five seconds from healthy volunteers and patients with CF. The measured T1 values of healthy lung parenchyma ranged from 1100 to 1400 ms and are in good agreement with previously reported literature values. The measured T1 values of diseased lung parenchyma in patients with CF ranged from 800 to 1000 ms and correlated with reduced regional pulmonary blood volume and blood flow as confirmed by qualitative gadolinium (Gd)-DTPA-enhanced MR pulmonary perfusion imaging. Indirect qualitative MRI of pulmonary ventilation is feasible using the paramagnetic effects of oxygen physically dissolved in blood. In Chapter 4, a more quantitative oxygen-enhanced pulmonary function test based on the slope of a plot of R1 vs. oxygen concentration  the oxygen transfer function (OTF)  was developed and tested in a pool of healthy volunteers and patients with CF. The lung T1 relaxation rate, R1, under normoxic conditions (room air, 21% O2) and the response to various hyperoxic conditions (40% – 100% O2) were studied. Lung T1 in healthy volunteers showed a relatively homogeneous distribution while they breathed room air and a homogeneous decrease under hyperoxic conditions. This T1 decrease from breathing room air to 100% O2 was statistically significant at P < 0.0001. Lung T1 in patients with CF showed an inhomogeneous distribution while they breathed room air and the observed lung T1 decrease under hyperoxia depended on the actual state of the diseased lung tissue. In the selected group of patients with CF, areas with reduced OTF also showed reduced perfusion, as confirmed by qualitative Gd-DTPA-enhanced MR pulmonary perfusion imaging. In Chapter 5, the feasibility and reproducibility of a noninvasive, rapid and quantitative pulmonary perfusion mapping method was evaluated using a two-compartment tissue model in combination with proton spin labeling within the imaging slice. Global and selective lung T1 maps were acquired from each subject. Quantitative perfusion maps were calculated from the global and selective T1 maps. The measured perfusion rates of the upper right lung in volunteers ranged from 400 to 600 m/100g/min. In patients with CF, perfusion defects detected using Gd-DTPA-enhanced MRI were also detected using the spin labeling method. The perfusion rates of diseased lung tissues were less than 200 m/100g/min. The proposed method showed a high intra-study reproducibility and low relative errors. In the first part of Chapter 6, a clinical protocol combining anatomical 1H MRI with the assessment of both OTF and pulmonary perfusion was established for the human lung and applied to patients with CF. In the selected group of patients with CF, areas with reduced oxygen enhancement showed reduced perfusion as confirmed by spin labeling perfusion imaging. These functional imaging results also correlated with anatomical MT-STIR-HASTE imaging results. The results demonstrate that this completely noninvasive clinical protocol has potential for clinical applications in the serial diagnosis of lung diseases such as CF. In the second part of Chapter 6, we compared pulmonary function before and after smoking by measuring arterial blood T1 and lung T1 using the clinical protocol. The results revealed that after smoking, both arterial blood and lung showed no significant changes in OTF, while arterial blood T1 was reduced and the pulmonary perfusion rate was increased. KW - Lungenfunktionsprüfung KW - NMR-Tomographie KW - 1H MRT KW - Lunge KW - Herzshuntdiagnostik KW - funktionell KW - anatomisch KW - 1H MRI KW - lung KW - cardiac shunt KW - functional KW - anatomical Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-14867 ER - TY - THES A1 - Walter, Dominik T1 - Adaptive Control of Ultrashort Laser Pulses for High-Harmonic Generation T1 - Adaptive Kontrolle ultrakurzer Laserpulse zur Erzeugung Hoher Harmonischer N2 - The generation of high harmonics is an ideal method to convert frequencies of the infrared- or visible range into the soft x-ray range. This process demands high laser intensities that are nowadays supplied by femtosecond laser systems. As the temporal and spatial coherence properties of the laser are transferred during the conversion process, the generated high harmonics will propagate as a beam with high peak-brightness. Under ideal conditions the generation of soft-x-ray pulses shorter than one femtosecond is possible. These properties are exploited in many applications like time-resolved x-ray spectroscopy. The topic of this thesis is the generation and optimization of high harmonics. A variety of conversion setups is investigated (jet of noble gas atoms, gas-filled hollow-fiber, water microdroplets) and theoretical models present ideas to further enhance the conversion efficiency (using excited atoms or aligned molecules). In different setups the peak intensity of the fundamental laser pulses is increased by spectral broadening and subsequent temporal compression. This is achieved with the help of pulse shaping devices that can modify the spectral phase and therefore also the temporal intensity distribution of laser pulses. These pulse shaping devices are controlled by an evolutionary algorithm. With this setup not only adaptive compression of laser pulses is possible, but also the engineering of specific laser pulse shapes to optimize an experimental output. This setup was used to influence the process of high harmonic generation. It is demonstrated that the spectral distribution of the generated soft-x-ray radiation can be controlled by temporal pulse shaping. This method to tailor high harmonics is complemented by spatial shaping techniques. These findings demonstrate the realization of a tunable source of soft-x-ray radiation. N2 - Die Erzeugung hoher Harmonischer ist eine ideale Methode zur Frequenzkonversion von Licht aus dem sichtbaren- oder Infrarotbereich in den weichen Röntgenbereich. Für diesen Prozess werden hohe Laserintensitäten benötigt, die heutzutage von Femtosekundenlasersystemen bereitgestellt werden können. Da die zeitlichen und räumlichen Kohärenzeigenschaften des Lasers während der Ereugung der hohen Harmonischen Frequenzen nicht verlorengehen, erhält man unter geeigneten Bedingungen räumlich gerichete Pulse weicher Röntgenstrahlung mit Pulsdauern unter einer Femtosekunde. Die hohe Frequenz der erzeugten Strahlung und die kurze Zeitstruktur sind für eine Vielzahl von Anwendungen von grossem Nutzen, z.B. der zeitaufgelösten Röntgenspektroskopie. Die vorliegende Arbeit beschäftigt sich insbesondere mit der Erzeugung und Optimierung Hoher Harmonischer. Es werden experimentelle Ergebnisse unterschiedlicher Aufbauten zur Frequenzkonversion untersucht (Gas Strahl aus Edelgasatomen, gasgefüllte Hohlfaser, Wasser-Mikrotröpfchen) und theoretische Modelle zur effizienteren Erzeugung hoher Harmonischer (Erzeugung in angeregten Atomen oder ausgericheten Molekülen). Um die zur Verfügung stehende Laserintensität weiter zu erhöhen, werden verschiedene Aufbauten zur spektralen Verbreiterung und anschliessenden zeitlichen Kompression genutzt. Dabei kommen Pulsformer zum Einsatz, mit denen sich die spektrale Phase der Laserpulse, und damit gleichzeitig deren zeitlicher Intensitätsverlauf, kontrollieren lässt. Die Pulsformer werden von einem evolutionären Algorithmus gesteuert, wodurch beispielsweise eine automatisierte Pulskompression möglich ist oder Pulsformen erzeugt werden können, die gezielt das Ergebnis eines Experimentes optimieren. Mithilfe eines solchen adaptiven optischen Aufbaus ist es möglich auch den Prozess der Erzeugung hoher Harmonischer zu beeinflussen. Wie gezeigt wird, lässt dich damit die spektrale Verteilung hoher Harmonischer steuern. Der Grad an Kontrolle der erzeugten Strahlung kann durch räumliche Pulsformung noch weiter erhöht werden. Somit ist eine durchstimmbare Quelle köhärenter weicher Röntgenstrahlung realisiert. KW - Frequenzvervielfachung KW - Ultrakurzer Lichtimpuls KW - Femtosekundenbereich KW - Adaptivregelung KW - ultrakurz KW - Hohe Harmonische KW - Pulsformung KW - Evolutionärer Algorithmus KW - Adaptive Optimierung KW - ultrashort KW - high harmonic generation KW - pulse shaping KW - evolutionary algorithm KW - adaptive optimization Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-21975 ER - TY - THES A1 - Wagner, Joachim T1 - Optische Charakterisierung von II-VI-Halbleiter-Oberflächen in Kombination mit First-Principles-Rechnungen T1 - Optical Characterisation of II-VI Semiconductor Surfaces in Combination with First Principles Calculations N2 - In dieser Arbeit sind Methoden der optischen Spektroskopie, insbesondere die Ramanspektroskopie (RS) und die Reflexions-Anisotropie-Spektroskopie (RAS), angewandt worden, um die Oberflächen von II-VI Halbleitern zu charakterisieren. Für die experimentellen Untersuchungen wurde eine eigens für diesen Zweck entwickelte UHV-Optikkammer benutzt. Diese einzigartige Möglichkeit, II-VI Halbleiterproben aus einer state-of-the-art MBE-Anlage mit einer UHV-Optikanlage zu kombinieren hat gezeigt, dass optische Spektroskopie sehr gut dafür geeignet ist, strukturelle Eigenschaften, z.B. Rekonstruktionen, und chemische Bindungen an Oberflächen, sowie die damit verbundene Schwingungsdynamik zu analysieren. Neben den experimentellen Arbeiten wurden u. a. first principles Rechnungen mittels der Dichtefunktionaltheorie im Rahmen der Lokalen-Dichte-Approximation durchgeführt. Damit konnten für die Oberflächen einerseits ihre geometrischen Eigenschaften, d.h die atomare Anordnung der Oberflächenatome, und andererseits auch ihre Dynamik, d.h. die Schwingungsfrequenzen und die Auslenkungsmuster der an der Rekonstruktion beteiligten Atome der Oberfläche und der oberflächennahen Schichten, im Rahmen der Frozen-Phonon-Näherung bestimmt werden. Die Kombination von experimenteller und theoretischer Vibrationsbestimmung von Oberflächen bietet also, neben den klassischen Oberflächen-Analysemethoden wie RHEED, LEED, XPS, Auger und SXRD, ein zusätzliches Werkzeug zur Charakterisierung von Oberflächen. Da die Frozen-Phonon-Näherung nicht elementarer Bestandteil des hier benutzten DFT-Programmcodes fhi96md ist, wurde diese Erweiterung im Rahmen dieser Arbeit durchgeführt. Die theoretische Berechnung von Schwingungsfrequenzen mit dynamischen Matrizen ist in einem Unterkapitel dargestellt. Die so berechneten Schwingungsfrequenzen für verschiedene Oberflächen-Rekonstruktionen konnten erfolgreich am Beispiel der reinen BeTe(100)-Oberfläche mit den experimentell mit der UHV-Ramanspektroskopie beobachteten Frequenzen verglichen werden. So gelang erstmalig die optische identifizierung von rekonstruktionsinduzierten Eigenschwingungen einer Oberfläche. Nach detaillierter Kenntnis der BeTe(100)-Oberfläche wurde die Ramanspektroskopie als Sonde benutzt, um die Entwicklung der BeTe-Oberfläche bei unterschiedlichen Behandlungen (Modifikation) zu verfolgen. Dabei dienten die früheren Ergebnisse als Referenzpunkte, um die modifizierten Spektren zu erklären. Zusätzlich wurde ein Konzept zur Passivierung der Te-reichen BeTe(100)-Oberfläche entwickelt, um diese Proben ohne einen technisch aufwendigen UHV-Transportbehälter über grössere Entfernungen transportieren zu können (z.B. zu Experimenten an einem Synchrotron). Mit der RAS wurden auch die Oberflächen von weiteren Gruppe II-Telluriden, nämlich die Te-reiche (2x1) CdTe(100)-Oberfläche, die Te-reiche (2x1) MnTe(100)-Oberfläche und die Hg-reiche c(2x2) HgTe(100)-Oberfläche untersucht. Schließlich wurde der Wachstumsstart von CdSe auf der BeTe(100)-Oberfläche im Bereich weniger Monolagen (1-5 ML) CdSe analysiert, wobei die hohe Empfindlichkeit der Ramanspektroskopie bereits den Nachweis einer Monolage CdSe erlaubte. N2 - In this thesis optical spectroscopy, especially Raman spectroscopy (RS) and reflection anisotropy spectroscopy (RAS), was used for characterisation of II-VI-semiconductor surfaces. For the experimental studies a specially designed UHV-optical chamber was applied. The unique combination of a state of the art molecular beam epitaxy (MBE) facility with this UHV-optical chamber distinctly proved that optical spectroscopy is a powerfull tool for analyzing the structural properties (e.g. reconstructions) and the chemical bindings at a surface, as well as its dynamical properties. Beside the experimental activities, first principles calculations within the framework of density functional theory (DFT) and local density approximation (LDA) were performed. Therefore the geometrical, statical properties (e.g. atomic positions) of the surface and near-surface atoms could be determined. Additionally, their dynamical properties (e.g. displacement patterns and vibrational frequencies) were calculated with the frozen phonon approximation. This combination of experimental and theoretical determination of the surface dynamics offers an additional tool for surface characterisation beside the classical methods for surface analysis like RHEED, LEED, XPS, Auger and SXRD. Because frozen phonon calculations do not constitute an integral part of the available DFT programm code fhi96md, the extension was performed as a part of this thesis. The theoretical calculation of vibration frequencies with dynamical matrices is described in one of the subsections. The frequencies calculated in this way for different surface reconstructions were successfully compared with the experimentally observed frequencies in the case of pure BeTe(100) surfaces. Thus, the first optical identification of reconstruction-induced surface eigenvibration modes was realized. After this detailed knowledge of the BeTe(100) surface Raman spectroscopy was used as a probe to track the changes of the BeTe surface under different modifications. In doing so the previous result on the pure BeTe surfaces served as references to explain the modified spectra. Besides a concept for passivation of the tellurium rich BeTe(100) surface was developed to ease the transport to far away laboratories without using extensive UHV facilities. Additionally the surfaces of further group II-tellurides (e.g. Te-rich (2x1) CdTe(100), Te-rich (2x1) MnTe(100) and Hg-rich c(2x2) HgTe) has been investigated with the RAS. Finally the start of the CdSe growth on the BeTe(100) surface was analyzed in the region of 1-5 monolayers of CdSe. Within these experiments a high sensitivity for detecting even one monolayer of CdSe was achieved by Raman spectroscopy. KW - Zwei-Sechs-Halbleiter KW - Halbleiteroberfläche KW - Optische Eigenschaft KW - optisch KW - spektroskopie KW - Halbleiter KW - Oberfläche KW - DFT KW - optical KW - spectroscopy KW - semiconductor KW - surface KW - DFT Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8722 ER - TY - THES A1 - Wagenpfahl, Alexander Johannes T1 - Numerical simulations on limitations and optimization strategies of organic solar cells T1 - Numerische Simulationen von Limitierungen und Optimierungsstrategien organischer Solarzellen N2 - Continuously increasing energy prices have considerably influenced the cost of living over the last decades. At the same time increasingly extreme weather conditions, drought-filled summers as well as autumns and winters with heavier rainfall and worsening storms have been reported. These are possibly the harbingers of the expected approaching global climate change. Considering the depletability of fossil energy sources and a rising distrust in nuclear power, investigations into new and innovative renewable energy sources are necessary to prepare for the coming future. In addition to wind, hydro and biomass technologies, electricity generated by the direct conversion of incident sunlight is one of the most promising approaches. Since the syntheses and detailed studies of organic semiconducting polymers and fullerenes were intensified, a new kind of solar cell fabrication became conceivable. In addition to classical vacuum deposition techniques, organic cells were now also able to be processed from a solution, even on flexible substrates like plastic, fabric or paper. An organic solar cell represents a complex electrical device influenced for instance by light interference for charge carrier generation. Also charge carrier recombination and transport mechanisms are important to its performance. In accordance to Coulomb interaction, this results in a specific distribution of the charge carriers and the electric field, which finally yield the measured current-voltage characteristics. Changes of certain parameters result in a complex response in the investigated device due to interactions between the physical processes. Consequently, it is necessary to find a way to generally predict the response of such a device to temperature changes for example. In this work, a numerical, one-dimensional simulation has been developed based on the drift-diffusion equations for electrons, holes and excitons. The generation and recombination rates of the single species are defined according to a detailed balance approach. The Coulomb interaction between the single charge carriers is considered through the Poisson equation. An analytically non-solvable differential equation system is consequently set-up. With numerical approaches, valid solutions describing the macroscopic processes in organic solar cells can be found. An additional optical simulation is used to determine the spatially resolved charge carrier generation rates due to interference. Concepts regarding organic semiconductors and solar cells are introduced in the first part of this work. All chapters are based on previous ones and logically outline the basic physics, device architectures, models of charge carrier generation and recombination as well as the mathematic and numerical approaches to obtain valid simulation results. In the second part, the simulation is used to elaborate issues of current interest in organic solar cell research. This includes a basic understanding of how the open circuit voltage is generated and which processes limit its value. S-shaped current-voltage characteristics are explained assigning finite surface recombination velocities at metal electrodes piling-up local space charges. The power conversion efficiency is identified as a trade-off between charge carrier accumulation and charge extraction. This leads to an optimum of the power conversion efficiency at moderate to high charge carrier mobilities. Differences between recombination rates determined by different interpretations of identical experimental results are assigned to a spatially inhomogeneous recombination, relevant for almost all low mobility semiconductor devices. N2 - Stetig steigende Preise für Energie haben die Lebenshaltungskosten in Deutschland über die letzten Jahrzehnte maßgeblich beeinflusst. Gleichzeitig werden scheinbar extremere Wetterbedingungen, dürrere Sommer, ebenso wie regen und sturmreichere Winter aufgezeichnet. Dies könnten bereits heute die Vorboten eines kommenden, globalen Klimawandels sein. Berücksichtigt man die Endlichkeit fossiler Energieträger und die wachsende Ablehnung gegenüber nuklearer Energieerzeugung, führt kein Weg an einer genaueren Erforschung innovativer, erneuerbarer Energiequellen vorbei. Neben Wind- und Wasserkraft stellt die direkte Umwandlung von Sonnenlicht in elektrischen Strom einen der erfolgversprechendsten Ansätze dar. Seit Beginn der Synthese und der genaueren Untersuchungen organischer, halbleitender Polymere und Fullerene innerhalb der letzten Jahre, wurde eine neue Arte der Solarzellenherstellung, neben den bereits etablierten Technologien, denkbar. Zusätzlich zu klassischen Aufdampfverfahren können Solarzellen aus organischen Materialien in Lösung hergestellt und auf verschiedenartigste Materialien wie Plastik, Stoff oder Papier aufgebracht werden. Aufgrund der Unordnung in den aktiven Schichten verhalten sich solche Solarzellen jedoch anders als solche aus anorganischen Materialien. Eine organische Solarzelle ist ein komplexes elektrisches Bauteil, welches durch eine Anzahl physikalischer Effekte maßgeblich beeinflusst wird. So ist, beispielsweise, die Verteilung erzeugter Ladungsträger durch optische Interferenzeffekte bestimmt. Ladungstransport und Ladungsträgerrekombination stellen weitere Einflussfaktoren dar. Die experimentell gemessenen Strom-Spannungs-Kennlinien sind somit stets makroskopische Kombination mehrerer Effekte. Änderungen einzelner Parameter führen zu einer komplexen Änderung des elektrischen Verhaltens des Bauteils. Folgerichtig ist es notwendig, ein Modell zu entwickeln, welches das Verhalten organischer Solarzellen bei sich ändernden Umgebungsbedingungen, allgemeingültig vorhersagen kann. Im Rahmen dieser Arbeit wurde, zu diesem Zweck, eine eindimensionale, numerische Simulation entwickelt. Basierend auf Drift- und Diffusionsgleichungen für Elektronen, Löcher und Exzitonen kann der Ladungstransport in organischen Halbleitern beschrieben werden. Benötigte Generations- und Rekombinationsraten werden durch entsprechende Ratengleichungen bestimmt. Über die Poisson-Gleichung wird zudem das auftretende elektrische Feld innerhalb der Solarzelle berücksichtigt. Das resultierende differentielle Gleichungssystem ist jedoch nicht analytisch lösbar. Nur mit Hilfe spezieller numerischer Methoden, können gültige Lösungen gefunden werden. Hiermit kann das Verhalten organischer Solarzellen sehr gut beschrieben. Eine zusätzliche optische Simulation kann dazu benutzt werden, optische Interferenzeffekte zu berücksichtigen. Im des ersten Teiles dieser Arbeit werden Methoden und Modellvorstellungen für Prozesse in organischer Solarzellen vorgestellt. Die Kapitel bauen aufeinander auf und gehen nacheinander auf die grundlegende Physik, die Bauteilarchitektur, die Modelle der Ladungsträgergeneration und -rekombination, ebenso wie auf die benötigten mathematischen und numerischen Methoden ein. Beiträge zur aktuellen Forschung werden im zweiten Abschnitt vorgestellt. Diese Umfassen ein grundlegendes Verständnis der offenen Klemmspannung organischer Solarzellen. Diese wird entweder durch Oberflächenrekombination an den Elektroden oder durch Injektionsbarrieren limitiert. S-förmige Verformungen von gemessenen und simulierten Strom-Spannungs-Kennlinien konnten durch endliche Oberflächenrekombinationsgeschwindigkeiten erklärt werden. Aufgrund verminderter Extraktions- und Injektionseigenschaften entsteht eine spannungsabhängige Raumladungszone, welche diese oft beobachtete Verformung verursacht. Der Wirkungsgrad organischer Solarzellen konnte als Kompromiss zwischen Ladungsträgeranhäufung und -extraktion im Bauteil identifiziert werden. Dies führt letztendlich zu einem Optimum der Solarzelleneffizienz bei moderaten bis hohen Ladungsträgerbeweglichkeiten. Abweichungen experimentell unterschiedlich bestimmter Rekombinationsraten konnten auf eine räumlich inhomogene Verteilung der Ladungsträgerrekombination zurückgeführt werden. Diese wird durch selektive Kontakte erzeugt und ist für alle halbleitenden Bauelemente mit niedriger Mobilität relevant. KW - Organische Solarzelle KW - Fotovoltaik KW - Organischer Halbleiter KW - s-shape KW - Doppeldiode KW - Simulation KW - Solarzelle KW - Rekombination KW - Strom-Spannungs-Kennlinie Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-90119 N1 - zu ergänzende PACS-Nummern wären: 88.40.jr und 81.05.Fb (Quelle: http://www.aip.org/publishing/pacs/pacs-alphabetical-index) ER - TY - THES A1 - Väth, Stefan Kilian T1 - On the Role of Spin States in Organic Semiconductor Devices T1 - Die Rolle von Spin Zuständen in organischen Halbleiterbauteilen N2 - The present work addressed the influence of spins on fundamental processes in organic semiconductors. In most cases, the role of spins in the conversion of sun light into electricity was of particular interest. However, also the reversed process, an electric current creating luminescence, was investigated by means of spin sensitive measurements. In this work, many material systems were probed with a variety of innovative detection techniques based on electron paramagnetic resonance spectroscopy. More precisely, the observable could be customized which resulted in the experimental techniques photoluminescence detected magnetic resonance (PLDMR), electrically detected magnetic resonance (EDMR), and electroluminescence detected magnetic resonance (ELDMR). Besides the commonly used continuous wave EPR spectroscopy, this selection of measurement methods yielded an access to almost all intermediate steps occurring in organic semiconductors during the conversion of light into electricity and vice versa. Special attention was paid to the fact that all results were applicable to realistic working conditions of the investigated devices, i.e. room temperature application and realistic illumination conditions. N2 - Die vorliegende Arbeit behandelt den Einfluss der Elektronenspins auf grundlegende Prozesse in organischen Halbleitern. In den meisten Fällen wurde der Spineinfluss während der Umwandlung von Sonnenlicht in Elektrizität untersucht. Zusätzlich wurde in einer Studie der gegenteilige Prozess behandelt. Dabei wurde der Einfluss der Spins auf die Umwandlung von elektrischem Strom in Licht betrachtet. Es wurden viele verschiedene Materialsysteme verwendet, die mit einer Vielzahl an Methoden vermessen wurden, welche alle auf dem Prinzip der Elektronenspinresonanz beruhen. Dabei wurde stets die Messgröße variiert, was zu den verwendeten Messmethoden Photolumineszenz detektierte Magnetresonanz (PLDMR), elektrisch detektierte Magnetresonanz (EDMR) und Elektrolumineszenz detektierte Magnetresonanz (ELDMR) geführt hat. Zusam- men mit der gewöhnlichen Elektronenspinresonanz Spektroskopie führt diese Auswahl an vielfältigen Messmethoden dazu, dass so gut wie alle Zwischenschritte bei der Umwand- lung von Licht in Elektrizität als auch von Elektrizität in Licht untersucht werden können. Besonderes Augenmerk wurde darauf gelegt, dass alle Messungen auf realistische Bedingungen übertragbar sind, d.h. bei Raumtemperatur und unter normalen Beleuchtungsstärken und -wellenlängen. Zu Beginn der Arbeit wurde ein kurzer Überblick über die historische Entwicklung von organischen Solarzellen gegeben, zusammen mit der Erläuterung von grundlegenden Prozessen in den untersuchten Bauteilen, stets auch hinsichtlich der vorkommenden Spinzustände. Desweiteren wurde die Solarzellencharakterisierung und die Morphologie der aktiven Schicht diskutiert. Das darauf folgende Kapitel behandelte die theoretische Beschreibung des Magnetfeldeffekts auf Spinzustände und diverse Wechselwirkungsmechanismen. Darüber hinaus wurde diskutiert, wie Mikrowellen die vom Magnetfeld ausgerichteten Spins beeinflussen können. Zu guter Letzt wurden verschiedene Modelle vorgestellt, mit deren Hilfe sich die erzielten Ergebnisse interpretieren lassen. Das nächste Kapitel beschreibt schließlich detailliert die experimentellen Feinheiten, wie verwendete Materialien, Probenherstellung und verschiedene Spektrometer Konfigurationen. Das erste Ergebnis Kapitel beschreibt den Einfluss des Zusatzmittels 1,8-Dijodoktan auf das Materialsystem PTB7:PC70BM. Dies wurde mit Hilfe von konventioneller Elek- tronenspinresonanz untersucht, welche es ermöglicht zwischen Elektronen auf dem Akzeptor- und Polaronen auf dem Donormaterial zu unterscheiden. Ergänzend dazu wurden Röntgenphotoelektronenspektroskopiemessungen durchgeführt, welche zu dem Ergebnis führten, dass Jod trotz Hochvakuumtrocknung mit der relativen hohen Konzentration von (7.3±2.1)·1019 1 in dem Material verbleibt. Zudem bleibt Jod wahrscheinlich bevorzugt in der Akzeptorphase. Es wurde außerdem kein elektronischer Doping- effekt gefunden. Nichtsdestotrotz wird dieses Ergebnis einen Einfluss auf die zukünftige Wahl des Zusatzmittels haben. Kapitel 6 handelt von der Entstehung von Triplett Exzitonen in dem Materialsystem p-DTS(FBTTh2)2:PC70BM, wobei das Donormaterial aus löslichen kleinen Molekülen besteht, anstatt aus Polymeren. Mit Hilfe von PLDMR Messungen konnten die Entstehungsmechanismen Elektronenrücktransfer, sowie inter system crossing den verschiedenen Proben zugeordnet werden. Der genaue Mechanismus hängt jedoch stark von der Morphologie des untersuchten Materialsystems ab. Durch den Nachweis von Triplett Exzitonen bei Raumtemperatur konnte die Relevanz der Ergebnisse auch bei realen Bedingungen bestätigt werden. Vergleicht man das Triplett Vorkommen mit den So- larzelleneffizienzen konnte keine Korrelation erkannt werden. Daraus ergibt sich, dass Triplett Exzitonen für das untersuchte Materialsystem keine Effizienz limitierende Größe darstellen. Zum Abschluss wurde die Ausrichtung der Moleküle auf dem Substrat mit Hilfe von winkelabhängigen Messungen bestätigt. Der Einfluss des Zusatzmittels Galvinoxyl auf die Funktionsweise von organischen Solarzellen wird in Kapitel 7 untersucht. Es wurden PLDMR durchgeführt, die gezeigt haben, dass Galvinoxyl in der Lage ist Spin Zustände zu verändern, wie von der Literatur vorhergesagt. Aufgrund dessen handelt es sich um einen konkurrierenden Prozess gegenüber den erzeugten Spin resonanten Bedingungen. Durch die Messung an verschiedenen Doping Konzentrationen konnte ein Optimum von 3.2 % für das Materialsystem P3HT:PC60BM bestimmt werden. Trotzallem ist es unwahrscheinlich, dass der sehr große Anstieg des Photostroms in mit Galvinoxyl gedopten Solarzellen auf spinabhängige Prozesse zurückzuführen ist. Die Quantifizierung von spinabhängigen Prozessen in organischen Solarzellen bein- haltet viele Schwierigkeiten. Durch die Kombination des EDMR Messprinzips mit der Ladungsträgerextraktionsmethode OTRACE war es jedoch möglich, einen spinabhängigen Rekombinationsanteil von (0.012±0.009)% bei Raumtemperatur und (0.052±0.031)% bei 200 K für das Materialsystem P3HT:PC70BM zu bestimmen. Darüber hinaus wurde eine Interpretation eingeführt, die in der Lage ist, das Zustandekommen des EDMR Signals zu erklären. Im letzten Ergebnisteil (Kapitel 9) wurde der Fokus darauf gelegt, wie Spins die Funktionsweise von organischen Leuchtdioden (OLEDs) beeinflussen, die auf thermisch aktivierter verzögerter Lumineszenz (TADF) basieren. Dabei wurden verschiedene Detektionsverfahren verwendet, wobei sich heraus gestellt hat, dass ELDMR das einzig verwendbare darstellt. Damit konnten durch temperaturabhängige Messungen der energetische Unterschied zwischen dem Singulett- und Triplett Exciplex Zustand ∆EST bestimmt werden. Es ergaben sich (20.5±1.2) meV für THCA:BPhen und (68.3±5.4) meV für m-MTDATA:BPhen. Durch diese Messungen wurde zum ersten Mal zweifelsfrei der Einfluss von Spins in der Entstehung der Elektrolumineszenz von TADF OLEDs gezeigt. Aufgrund der Diskussion von möglichen Gründen, die für die verschiedenen Werte von ∆EST verantwortlich sind, konnten neue Vorgaben für zukünftige Materialkombinationen und -synthese gefunden werden. Zusammenfassend lässt sich sagen, dass die vorliegende Arbeit einen bedeutenden Beitrag geliefert hat, um spinabhängige Prozesse in organischen Halbleitern aufzuklären. Darauf aufbauend werden Folgestudien vielleicht eines Tages sämtliche spinabhängigen Prozesse in diesen viel versprechenden Materialsystemen erklären können. KW - Organischer Halbleiter KW - Elektronenspin KW - Polymerhalbleiter KW - Organic Semiconductors KW - Electron Spin Resonance KW - Elektronenspinresonanz KW - Spin KW - Spin-eins-System Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-141894 ER - TY - THES A1 - Vrdoljak, Pavo T1 - Präparation und Untersuchung verborgener Metall/Molekül-Kontaktgrenzflächen mit oberflächensensitiven Methoden T1 - Preparation and investigation of burried metal/molecule contact interfaces with surface sensitive methods N2 - Das Wissen um die strukturellen und elektronischen Eigenschaften verborgener Metall-Organik-Grenzflächen ist entscheidend für die Optimierung und Verbesserung der Leistungsfähigkeit von auf organischen Halbleitern basierenden Bauteilen. In der vorliegenden Arbeit wurde ein Delaminationskonzept für das Ultrahochvakuum (UHV) umgesetzt und optimiert, mit dessen Hilfe an Modellsystemen verborgene Grenzflächen für oberflächensensitive Methoden zugänglich gemacht und im Anschluss hinsichtlich ihrer elektronischen und topographischen Eigenschaften untersucht wurden. Die Erfahrungen und Ergebnisse dieser Arbeit stellen im Bezug auf Untersuchungen und die Optimierung von organischen Bauteilen und ihre verborgenen Grenzflächen einen neuartigen Zugang dar. Der erste Schwerpunkt der Arbeit befasste sich am Beispiel von verborgenen Metall/NTCDA- und Metall/ PTCDA-Grenzflächen mit der Frage, wie verborgene Grenzflächen erfolgreich für oberflächensensitive Methoden zugänglich gemacht werden können. Nach einer Eruierung eines Klebstoffs, dessen Eigenschaften den Anforderungen hinsichtlich der Festigkeit, Verarbeitung und UHV-Tauglichkeit genügt, konnte gezeigt werden, dass es mit ausreichender Sorgfalt möglich ist, einen unmittelbaren Zugang zu verborgenen Grenzflächen zu erhalten. Es konnten dabei Kontakte von ca. 10 × 15 mm2 Größe offengelegt werden. Dabei zeigte sich auch, dass der Klebstoff für die Qualität der Delamination eine entscheidende Rolle spielt. Auf der einen Seite bestimmt das Klebeverhalten des Klebstoffs die Größe der möglichen Delaminationsfläche, und auf der anderen Seite bestimmt seine chemische Zusammensetzung das Ausgas- und Diffusionsverhalten, welche Einfluss auf den Kontaminationsgrad der delaminierten Grenzflächen haben. Mit Hilfe von dickeren Metallschichten konnte erreicht werden, dass leichter zu verarbeitende Klebstoffe (Klebestreifen) für die Delamination verborgener Grenzflächen verwendet werden können. Auch konnte die gesamte Prozedur, eine verborgene Grenzfläche zu präparieren und zu delaminieren, erfolgreich in-situ im UHV durchgeführt werden. Als schwierig zeigte sich die thermische Desorption von Molekülschichten von delaminierten Metallkontakten. Bei der thermischen Ausdünnung (100-250_C) wird unweigerlich die Morphologie des darunter liegende Metallkontakts verändert. Zudem wurden Konzepte getestet, mit welchen PTCDA-Schichten von delaminierten Kontakten mittels Lösungsmitteln entfernt wurden, um im Anschluss daran die Kontakttopographie zu untersuchen. Es wird vermutet, dass der Einfluss der Lösungsmittel auf den delaminierten Kontakt zwar gegeben, jedoch gering ist. Im zweiten Schwerpunkt dieser Arbeit konnten für verborgene Metall(Au,Ag)/PTCDA und Ag/NTCDA-Grenzflächen nach ihrer Delamination einige Gemeinsamkeiten festgestellt werden: Nach der Delamination der Top-Kontakte befinden sich auf den Metallkontakten inhomogene Molekülschichten. Dabei waren auf den PTCDA-bedeckten Kontakten dickere Schichten (4-5 ML PTCDA auf Ag-Kontakt) und auf den NTCDA-bedeckten Kontakten große Bereiche von mindestens 2 mm im Durchmesser mit Monolagen vorhanden. Auch topographisch zeigten sich Gemeinsamkeiten. So wiesen die mit Molekülmultilagen bedeckten Bereiche glatte Oberflächen auf, während die Metalloberflächen selbst zerklüftete, mäanderartige und raue Oberflächen aufwiesen. Eine weitere Gemeinsamkeit war, dass der Klebstoff die PE-spektroskopische Untersuchung der Valenzzustände erheblich erschwerte. Des Weiteren konnte die Molekülschicht zwar thermisch ausgedünnt werden, jedoch konnten danach keine Valenzzustände untersucht werden. Als letzter gemeinsamer Gesichtspunkt waren topographische Einflüsse des Klebstoffs, welcher durch seine mikro- wie makroskopischen thermischen Verformungen und Blasenbildung massiv die topographische Struktur des Kontakts verändert. Bei der Untersuchung von in-situ delaminierten verborgenen Grenzflächen stand zunächst die Metall(Au,Ag)/PTCDA-Grenzflächen im Fokus. Bei delaminierten Au/PTCDA-Kontakten war die offengelegte Grenzfläche nach der Delamination nicht intakt, und es fanden sich Löcher in der Metallschicht mit mehreren μm Durchmesser. Durch diese waren Bestandteile des Klebstoffs (VACSEAL) photoelektronenspektroskopisch und lichtmikroskopisch auf der verborgenen Grenzfläche zu sehen, die gerade in der UV-Photoelektronenspektroskopie (UPS) eine Untersuchung der Valenzzustände dünner PTCDA-Schichten besonders erschweren. Das HOMO der PTCDA-Multilage liegt bei delaminierten Au/PTCDA-Kontakten bei etwa 2,3eV. Die Untersuchung von Ag/PTCDA-Kontakten zeigte intakte Metallkontaktfilme nach der Delamination. Es konnte zudem die Molekülschicht thermisch bei 260_C auf 2-4 Monolagen erfolgreich ausgedünnt werden, so dass Valenzzustände untersucht werden konnten. Der Klebstoff erschwerte jedoch auch hier die Untersuchung. Aufgrund verbreiterter Spektren konnten die Lagen des HOMO und FLUMO des in-situ delaminierten und ausgedünnten Ag/PTCDA-Kontakts ungefähr bei 1,9 eV bzw. 0,7 eV bestimmt werden. Weiterhin wurden offengelegte Ag/NTCDA-Grenzflächen untersucht. Bei Ag/ NTCDAKontakten ist es gelungen, durch sukzessives Erhöhen der Metallschichtdicke den Einfluss des Klebstoffs zu minimieren bzw. gänzlich ohne diesen auszukommen. Bereits ab Silberschichtdicken von 2,5 μm können verborgene Grenzflächen mit geschickter Technik so delaminiert werden, dass sich Kontaktbereiche ohne Klebstoffanteile ergeben. Dabei wurde ein Drittel des Kontakts verklebt und die restlichen zwei Drittel standen nach der Delamination frei von Klebstoffbestandteilen für Untersuchungen zur Verfügung. Ein weiterer Erfolg bezüglich der Delamination war nicht nur, dass leichter zu verarbeitende Klebstoffe (Klebestreifen) verwendet werden konnten, sondern vor allem, dass es gelang, Ag/NTCDA-Kontakte zu delaminieren, deren Molekülschichtdicken im Monolagenbereich vorlagen. Damit konnte zum ersten Mal die direkte Molekül-Metall-Wechselwirkung an der verborgenen Grenzfläche untersucht werden, ohne dass der Kontakt für die Klebstoffaushärtung geheizt und die NTCDA-Schicht thermisch desorbiert werden musste. Das mit UPS ermittelte HOMO lag dabei bei 2,3 eV und das FLUMO bei 0,6 eV. Zudem wurde eine Austrittsarbeit von 4,9 eV ermittelt. Ferner konnte die Valenzstruktur eines vollständig in-situ präparierten und delaminierten Kontakts im UHV untersucht werden. Die Ergebnisse zeigten keinerlei Unterschiede zu den Kontakten, die für die Verklebung an Luft gebracht wurden. Ferner wurde ein Modell vorgestellt, mit dem erklärt werden kann, weshalb sich nach der Delamination nur einige wenige Moleküllagen auf dem Metallkontakt befinden. Bei den allgemeinen topographischen Untersuchungen ergab sich, dass die delaminierten Ag/NTCDA-Kontakte relativ rau mit einer RMS-Rauheit im Bereich von 18-24 nm und einer Skewness von 0,5 bis 1,5 waren. Ebenfalls wurden zwei Auffälligkeiten von delaminierten Ag/NTCDA-Kontakten untersucht: Die erste waren topographische Strukturen, die im Lichtmikroskop Löcher in der Metallschicht zu sein schienen. Diese erwiesen sich im Rasterkraftmikroskop (RKM) als lokal begrenzte Bereiche mit erhöhter Rauheit. Die zweite topographische Auffälligkeit waren Bereiche auf den delaminierten Ag/NTCDA-Kontakten, die im Lichtmikroskop als dunkle Flecken verschiedener Größe erschienen. Bei RKM-Untersuchungen konnten die dunklen Bereiche als NTCDA-Kristallite identifiziert werden, deren Dicke zwischen 500-600 nm lag. Zum Abschluss soll an dieser Stelle noch angemerkt werden, dass die Übertragung der Erfahrungen und Ergebnisse dieser Arbeit auf andere Systeme möglich ist. Das hier erfolgreich angewandte Delaminationskonzept besticht durch einfache Handhabung und Untersuchungsmöglichkeiten im UHV. Gerade im Hinblick auf eine vollständige in-situ Präparation und Delamination gibt es jedoch noch erhebliches Optimierungspotential, bis die Untersuchung von verborgenen Grenzflächen anderer Systeme, die besonders empfindlich gegenüber Umgebungsbedingungen sind, erfolgreich durchgeführt werden und zur Optimierung von "organischen" Bauteilen beitragen können. N2 - The knowledge of structural and electronic properties of buried metal/organic semiconductor interfaces is crucial for the optimisation and the improvement of devices based on organic semiconductors. The present thesis establishes an optimised concept of a delamination technique suitable for ultra high vacuum (UHV) with which model systems of buried interfaces were made accessible for surface sensitive methods which were applied to investigate their electronic and topographical properties. The experience with and results of this work are valuable for the investigation and optimisation of organic devices and their buried interfaces. A primary focus of this work is on the question how buried interfaces could be accessed successfully for surface sensitive methods using buried metal/NTCDA and metal/PTCDA interfaces as model systems. Having found an adhesive which was able to meet the demands of strength, processing and UHV-suitability it was proved that it is possible, with some care, to access the buried interfaces directly. Contacts of approximately 10 × 15 mm2 in size were accessed. Furthermore, the experience showed that the adhesive plays a decisive role for the quality of delaminated contacts: On the one hand the size of the delaminated contacts is determined by the properties of the adhesive, on the other hand its chemical compounds determine the degassing and diffusion properties which have an influence on the degree of contamination of the delaminated interface. Moreover adhesive tapes were successfully used, which were easy to handle for the delamination of buried interfaces by means of thicker metal contact layers. Moreover, the whole process of preparation and subsequent delamination of a buried interface was successfully performed in-situ in UHV. The thermal desorption of molecular layers from delaminated metal contacts proved to be difficult. Thinning out the molecular layers thermally (100−250_C), makes the change in morphology of the metal contact underneath inevitable. Additionally, concepts are discussed with which layers of PTCDA were removed from delaminated contacts by means of solvents in order to investigate the contact topography thereupon. It is assumed that there is an influence of the solvents on the delaminated contact but on a small scale. The second focus of the thesis is on the investigation of the electronical and topographical properties of the buried interfaces, for which some similarities between delaminated metal (Au,Ag)/ PTCDA- and Ag/NTCDA interfaces were found: After the delamination of top-contacts there were inhomogeneous layers of molecules on the metal contacts. Whereas PTCDA covered metal contacts had thicker molecular layers (4 − 5 ML PTCDA on Ag), NTCDA covered contacts showed only one monolayer coverage over large areas of at least 2 mm in diameter. There were also topographical similarities. Regions with multilayer coverage showed smooth surfaces whereas metal surfaces showed a fissured, meander-like and rough surface. Both contact systems also had in common that the adhesive made PES investigations of valence states very difficult. Furthermore, it was possible to thin out the molecular layers thermally but afterwards no valence states could be measured. The last aspect both contacts had in common was the influence of the adhesive on the topography of the metal surfaces. The topographical structures of the contacts were massively altered due to thermally induced, micro- and macroscopically noticeable changes as well as the creation of blisters of the adhesive. Investigating in-situ delaminated buried interfaces, the focus was on metal (Au,Ag)/PTCDA interfaces first. The revealed interfaces of delaminated Au/PTCDA contacts were not intact after delamination and showed holes in the metal layer of several microns in diameter. Through these holes the adhesive (VACSEAL) could be measured and seen on the buried interface by means of PES and optical microscopy, respectively, which made UPS investigations of valence states of thin PTCDA layers rather difficult. The PTCDA multilayer HOMO was found to be at approx. 2.3 eV for delaminated Au/PTCDA contacts. The investigation of Ag/PTCDA contacts showed intact metal films after delamination. The molecular layers could be successfully desorbed thermally at 260_C to 1-3 monolayers so that valence states were investigated. The adhesive, however, made investigations rather difficult. The spectra of the in-situ delaminated and thermally desorbed Ag/PTCDA contact were noticeably broadened so that the positions of HOMO and FLUMO could only be estimated at 1.9 eV and 0.7 eV, respectively. Additionally, interfaces of Ag/NTCDA contacts were investigated. By incrementally increasing the thickness of the metal layer the influence of the adhesive on the Ag/NTCDA contacts was successfully minimised or even made the use of the liquid adhesive dispensable. Even at silver thicknesses of 2.5 μm the buried interfaces can be delaminated in that way that there are parts of the contact having no adhesive underneath. In this case one third of the contact was glued to a substrate and the remaining two thirds were investigated without amounts of adhesive material. Not only the usage of adhesive tapes, which are easier to handle, was a further success as far the delamination process is concerned, but also the fact that Ag/NTCDA contacts were delaminated in that way which had a coverage of only a few monolayers. Consequently, the interaction between molecules and metal of the buried interface could be investigated without the contact being heated for curing the adhesive or for molecule desorption. With UPS it was found that the HOMO position was at 2.3 eV and the position of the FLUMO at 0.6 eV. Additionally, the work function was determined to be 4.9 eV. Furthermore, the valence structure of a contact was investigated which was prepared and delaminated completely in-situ without breaking the UHV. The results did not show any discrepancies to those where contacts were being exposed to air for gluing. Also, a model is presented which could help to explain why only monolayers remain on the metal contact after delamination. Investigations of the topography revealed that delaminated Ag/NTCDA contacts are relatively rough at a RMS-roughness in the range of 18-24 nm and had a skewness of 0.5 to 1.5. Finally, two peculiarities of delaminated Ag/NTCDA contacts were investigated: The first one were topographical structures which seemed to be holes in the metal layer seen through the optical microscope. By means of atomic force microscopy (AFM) it was revealed that these structures where small areas of a higher roughness. The second topographical peculiarity were dark areas of different sizes on delaminated Ag/NTCDA contacts seen in the optical microscope. AFM investigations could identify these dark areas as NTCDA-crystallites which had a thickness between 500 to 600 nm. Summing up, it should be noted that all experiences and results of this work can also be translated successfully to other systems. The advantages of the delamination concept used here is the simple handling and the possibility to do investigations under UHV conditions. Regarding the complete in-situ preparation and delamination there is still a potential to optimise the set-up. In doing so, other systems of buried interfaces being sensitive to ambient conditions could be investigated successfully in order to improve and to optimise organic based electronic devices. KW - Grenzfläche KW - Delamination KW - Organischer Halbleiter KW - Metall KW - metall-organisch KW - verborgene Grenzflächen KW - Delamination KW - lift-off KW - metal-organic KW - burried interfaces KW - delamination KW - lift-off Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-64590 ER - TY - THES A1 - Vorndran, Elke T1 - Rapid-Prototyping hydraulisch härtender Calcium- und Magnesiumphosphatzemente mit lokaler Wirkstoffmodifikation T1 - Rapid-prototyping of hydraulic calcium- and magnesium phosphate cements with local drug modification N2 - Ziel dieser Arbeit war die Herstellung individuell formbarer Strukturen mittels des 3D-Pulverdrucks auf Basis von bei Raumtemperatur hydraulisch abbindenden Knochenzementpulvern. Neben der Entwicklung neuartiger Zementformulierungen auf Basis von Magnesiumphosphaten war vor allem die gleichzeitige Ausstattung der Werkstoffe mit temperaturlabilen und bioaktiven Verbindungen ein wichtiger Entwicklungsschritt. Die Lokalisation der Wirkstoffe korreliert dabei mit entsprechenden Farbinformationen im Design der Konstrukte, die durch einen Mehrfarbendrucker physikalisch abgebildet werden. Das auf Calciumphosphat basierende System hat den Nachteil, dass die Abbindereaktion bei stark sauren pH-Werten abläuft, was negative Auswirkungen auf die gleichzeitige Ausstattung mit sensitiven Wirkstoffen hat. Zur Lösung dieser Problematik wurde ein neues Knochenzementpulver auf Magnesiumphosphatbasis entwickelt, welches unter neutralen pH-Bedingungen mit ammoniumhaltigem Binder zu dem Mineral Struvit abbindet. Das Zementpulver aus Trimagnesiumphosphat wurde bezüglich der pulvertechnologischen Eigenschaften, wie Partikelgröße, Partikelgrößenverteilung, Glättungseigenschaften und Schüttdichte sowie hinsichtlich des Abbindeverhaltens charakterisiert und für den Druckprozess optimiert. Die hohe Strukturgenauigkeit ermöglichte die Darstellung von makroporösen Strukturen mit einem minimalen Porendurchmesser von ca. 200 µm. Gute mechanische Kennwerte der gedruckten Strukturen, sowie eine hohe Umsetzungsrate zur gewünschten Phase Struvit wurden durch eine Nachhärtung in Ammoniumphosphatlösung erhalten. Die Druckfestigkeit betrug > 20 MPa und der Phasenanteil von Struvit konnte auf insgesamt 54 % gesteigert werden. Die Darstellung von wirkstoffmodifizierten Calciumphosphat- und Magnesiumphosphatstrukturen durch Verwendung eines Mehrfarbendruckers wurde beginnend vom Design der Strukturen bis hin zur experimentellen Bestimmung der Korrelation von Farbinformation und Binderapplikation etabliert. Zur Sicherstellung einer hohen Druckqualität und der Ortsständigkeit gedruckter Wirkstoffe erwies sich eine zusätzliche Modifikation des Tricalciumphosphatpulvers mit quellfähigen Polymeren (Hydroxypropylmethyl-cellulose (HPMC) bzw. Chitosan) als erfolgreich. Eine maximale Auflösung von ca. 400 µm konnte für eine HPMC/Chitosan/Calciumphosphat-Variante erreicht werden, während das hochreaktive Magnesiumphosphat/Magnesiumoxid-System eine Auflösung von 480 µm aufwies. Die Ortsständigkeit eingebrachter Lösungen war Voraussetzung für die Steuerung der Freisetzungskinetik. Das Freisetzungsverhalten in vitro wurde in Abhängigkeit von der Wirkstofflokalisation (homogen, Depot, Gradient) innerhalb der Matrix und unter Einbringung zusätzlicher polymerer Diffusionsbarrieren für den Wirkstoff Vancomycin untersucht. Dabei zeigte sich, dass die Modifikation der Matrices mit Polymeren zu einer verzögerten Freisetzung führte. Die lokale Wirkstoffmodifikation der Matrices in Form eines Depots oder Gradienten hatte Einfluss auf die Freisetzungskinetik, wobei eine lineare Freisetzung mit der Zeit (Kinetik 0. Ordnung) erreicht werden konnte. Die applizierten Wirkstoffe umfassten sowohl niedermolekulare Verbindungen, wie etwa das Antibiotikum Vancomycin oder das Polysaccharid Heparin, als auch proteinbasierte Faktoren wie den Knochenwachstumsfaktor rhBMP-2. Beurteilt wurde die pharmakologische Wirksamkeit der Verbindungen nach dem Druck, sowie nach der Freisetzung aus einer Calciumphosphatmatrix für den Wirkstoff Vancomycin. Es konnte belegt werden, dass die biologische Aktivität nach dem Druckprozess zu über 80 % erhalten blieb. Limitierend war der stark saure pH-Wert bei bruschitbasierten Systemen, der zu einer Inaktivierung des Proteins führte. Diesem Problem könnte durch die Nutzung des neutral abbindenden Magnesiumphosphatsystems entgegengewirkt werden. Abschließend erfolgten eine mikrostrukturelle Charakterisierung der Calciumphosphat- und Magnesiumphosphatmatrices mittels µ-CT-Analyse und Heliumpyknometrie, sowie eine quantitative Phasenanalyse nach Rietveld. Experimentell konnte nachgewiesen werden, dass mit Hilfe des 3D-Pulverdruck die Darstellung von Makroporen > 200 µm möglich ist. Die Analyse der Phasenzusammensetzung ergab, dass die Umsetzungsrate von Tricalciumphosphat und Trimagnesiumphosphat zu den gewünschten Phasen Bruschit und Struvit infolge des Nachhärtungsprozesses signifikant gesteigert werden konnte. Im Zuge dessen nahm die Porosität der gedruckten Matrices der Phase Struvit von 58 % auf 26 % und der Phase Bruschit von 47 % auf 38 % ab. N2 - Aim of this study was the room temperature fabrication of individually formed structures via 3D-powder printing based on hydraulic bone cements. In addition to the development of a novel cement formulation composed of magnesium phosphate, the simultaneous modification of matrices during the printing process with temperature sensitive and bioactive drugs was an important part of the work. The drug localization within the matrices is hereby correlated with an analogous colour design of the structures, which is physically reproduced by the multi-colour-printer. The calcium phosphate based system has the disadvantage of a strongly acidic setting reaction, which has negative effects on the simultaneous modification with sensitive bioactive agents. To solve this problem a novel bone cement formulation based on magnesium phosphate was established. This cement reacts with ammonium based binder solution within seconds to form the mineral struvite at neutral pH. The technological properties of the of trimagnesium phosphate cement powder, including particle size, particle size distribution, spreadability, powder density, and the setting behaviour, were characterized and optimized for the printing process. The high structural accuracy enabled the production of macroporous structures with a minimal pore diameter of approximately 200 µm. Proper mechanical characteristics of the printed structures as well as a high degree of conversion to the struvite phase were achieved by post-hardening in ammonium phosphate solution. The compressive strength could be increased to more than 20 MPa and the phase fraction of struvite could be increased to a maximum value of a total of 54 %. The fabrication of drug loaded calcium phosphate and magnesium phosphate scaffolds using a multi-colour-printer was established, beginning with the structure design and following the experimental verification of the correlation between the colour information and the applied binder. To guarantee a high accuracy of printing and the localization of the printed drugs, a supplemental modification of the tricalcium phosphate powder with swellable polymers (hydroxypropylmethylcellulose (HPMC) or chitosan) was successful. A maximum resolution of about 400 µm was achieved by an HPMC/chitosan/calcium phosphate composition, whereas the highly reactive magnesium phosphate/magnesium oxide system showed a resolution of about 480 µm. The localization of the applied solutions was a prerequisite to control the release kinetics of the drugs. The release kinetic of vancomycin was investigated in vitro depending on the drug localization (homogeneous, depot, gradient-like) within the matrix and by adding additional polymeric diffusion barriers. It could be shown that the polymeric modification of the matrices resulted in a delayed drug release. By discrete and depot-like or graded drug distributions within the matrices the release kinetic could be controlled, achieving a linear release with time (zero order release). The administered agents involved both low molecular compounds like the antibiotic vancomycin or the polysaccharide heparin and protein based factors like bone morphogenic factor rhBMP-2. Evaluation of pharmacological activity of the agents after printing as well as after release of vancomycin from a calcium phosphate matrix was determined, indicating that the bulk biological activity of more than 80 % was retained during the printing process. The limiting factor of the brushite based system was the strong acidic pH, which resulted in an inactivation of protein-based bioactives. This problem may be solved by using neutrally setting magnesium phosphate systems. Finally a microstructural characterization of calcium phosphate and magnesium phosphate matrices by µ-CT analysis and helium pycnometry as well as a quantitative phase analysis by Rietveld was performed. It was demonstrated, that 3D-printing allows the manufacturing of macro pores > 200 µm. The analysis of phase composition showed a significant increase of the degree of conversion from tricalcium phosphate or trimagnesium phosphate to the phases brushite or struvite due to the post hardening process. Hence the porosity of the printed matrices decreased from 58 % to 26 % for struvite and from 47 % to 38 % for brushite. KW - 3D-Druck KW - Calciumphosphate KW - 3D Pulverdruck KW - Calciumphosphat KW - Magnesiumphosphat KW - 3D powder printing KW - calcium phosphate KW - magnesium phosphate KW - Magnesiumphosphate KW - Rapid Prototyping KW - Kontrollierte Wirkstofffreisetzung Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-70245 ER - TY - THES A1 - Vogt, Matthias Guido T1 - Elektronische Eigenschaften von Wabengittern mit starker Spin-Bahn-Kopplung T1 - Electronic Properties of honeycomb lattices with strong spin-orbit coupling N2 - Im Rahmen dieser Arbeit wurden die elektronischen Eigenschaften von Graphen auf Metalloberflächen mittels Rastertunnelmikroskopie und Quasiteilcheninterferenz (englisch quasiparticle interference, QPI)-Messungen untersucht. Durch das Verwenden schwerer Substrate sollte die Spin-Bahn-Wechselwirkung des Graphen verstärkt werden und damit eine Bandlücke am K-Punkt der Bandstruktur mittels QPI beobachtet werden. Um das Messen von QPI auf Graphen zu testen, wurde auf der Oberfläche eines SiC(0001)-Kristalls durch Erhitzen Graphen erzeugt und mit dem Rastertunnelmikroskop untersucht. Dieses System wurde schon ausführlich in der Literatur beschrieben und bereits bekannte QPI-Messungen von Streuringen, die auf den Dirac-Kegeln des Graphen am K-Punkt basieren, konnte ich auf gr/SiC(0001) in guter Qualität erfolgreich reproduzieren. Anschließend wurde Graphen nach einem wohlbekannten Verfahren durch Aufbringen von Ethylen auf ein erhitztes Ir(111)-Substrat erzeugt. Dieses gr/Ir(111)-System diente auch als Grundlage für Interkalationsversuche von Bismut (gr/Bi/Ir(111)) und Gadolinium (gr/Gd/Ir(111)) zwischen das Graphen und das Substrat. Auf gr/Bi/Ir(111) wurde ein schon aus der Literatur bekanntes Netzwerk aus Versetzungslinien beobachtet, dem zusätzlich eine Temperaturabhängigkeit nachgewiesen werden konnte. Beim Versuch, Gadolinium zu interkalieren, wurden zwei verschieden Oberflächenstrukturen beobachtet, die auf eine unterschiedlich Anordnung bzw. Menge des interkalierten Gadoliniums zurückzuführen sein könnten. Auf keinem dieser drei Systeme konnten allerdings Streuringe mittels QPI beobachtet werden. Als Vorbereitung der Interkalation von Gadolinium wurden dessen Wachstum und magnetische Eigenschaften auf einem W(110)-Kristall untersucht. Dabei konnte eine aus der Literatur bekannte temperaturabhängige Austauschaufspaltung reproduziert werden. Darüber hinaus konnten sechs verschieden magnetische Domänen beobachtet werden. Zusätzlich sind auf der Oberfläche magnetische Streifen auszumachen, die möglicherweise auf einer Spinspirale basieren. Als Grundlage für die mögliche zukünftige Erzeugung Graphen-artiger Molekülgitter wurde das Wachstum von H-TBTQ und Me-TBTQ auf Ag(111) untersucht. Die Moleküle richten sich dabei nach der Oberflächenstruktur des Silber aus und bilden längliche Inseln, deren Kanten in drei Vorzugsrichtungen verlaufen. Auf H-TBTQ wurde zudem eine zweite, Windmühlen-artige Ausrichtung der Moleküle auf der Oberfläche beobachtet. Auf den mit den Molekülen bedeckten Stellen der Oberfläche wurde eine Verschiebung des Ag-Oberflächenzustands beobachtet, die mit einem Ladungstransfer vom Ag(111)-Substrat auf die TBTQ-Moleküle zu erklären sein könnte. N2 - In this thesis, the electronic properties of graphene on metal surfaces were investigated by scanning tunneling microscopy and quasiparticle interference (QPI) measurements. In order to enhance the spin orbital interaction of the graphene and possibly observe a band gap at the K-point of the band structure via QPI, substrates with heavy atoms were used. To test the ability to measure QPI on graphene, graphene was produced on the surface of a SiC(0001) crystal by heating and examined with a scanning tunneling microscope. This system has already been described in detail in the literature and I was able to successfully reproduce QPI measurements of clearly recognizable scattering rings, which are due to the Dirac cones of the graphene at the K-point Afterwards, graphene was produced by a well-known process by applying ethylene to a heated Ir(111) substrate. This gr/Ir(111) system also served as a basis for intercalation experiments of bismuth (gr/Bi/Ir(111)) and gadolinium (gr/Gd/Ir(111)) between the graphene and the substrate. On gr/Bi/Ir(111), a network of dislocation lines known from literature was observed, which also showed a temperature dependence. In the attempt to intercalate gadolinium, two different surface structures were observed which could be due to a different arrangement or quantity of the intercalated gadolinium. However, on none of these three systems scattering rings were observed by QPI. In preparation for the intercalation of gadolinium, its growth and magnetic properties were investigated on a W(110) substrate. A temperature-dependent exchange splitting of the surface density of states known from the literature could be reproduced. In addition, six different magnetic domains and magnetic stripes were observed on the surface, which may be based on a spin spiral. The growth of H-TBTQ and Me-TBTQ on Ag(111) was investigated as a basis for a possible subsequent generation of graphene-like molecular lattices in the future. The molecules are aligned to the surface structure of the silver and form elongated islands with edges in three preferred directions. H-TBTQ also appeared in a second, windmilllike orientation of the molecules on the surface. A shift of the Ag surface state was observed on the surface areas covered by the molecules, which might be explained by a charge transfer from the Ag(111) substrate to the TBTQ molecules. KW - Spin-Bahn-Wechselwirkung KW - Graphen KW - Rastertunnelmikroskopie KW - Wabengitter KW - Tribenzotriquinacen KW - Quasiteilcheninterferenz Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-207506 ER - TY - THES A1 - Vogt, Gerhard Sebastian T1 - Adaptive Femtosekunden-Quantenkontrolle komplexer Moleküle in kondensierter Phase T1 - Asaptive femtosecond quantum control of complex molecules in the condensed phase N2 - Die Bildung verschiedener Isomere durch Änderung der molekularen Struktur spielt eine wichtige Rolle in vielen Gebieten der Physik, Chemie und Biologie. Die Kontrolle dieser Reaktionen ist daher eine sehr interessante Herausforderung und von großer Bedeutung für viele verschiedene Bereiche. Die Entwicklung der letzten Jahre hat gezeigt, dass adaptive Femtosekunden Quantenkontrolle eine ausgesprochen geeignete Methode ist, um chemische Reaktionen zu kontrollieren. Die vorliegende Arbeit behandelt die Beobachtung und Kontrolle von solchen Isomerisierungsreaktionen in biologisch und chemisch relevanten Systemen. Dazu wurde die Reaktionsdynamik eines in Methanol gelösten Modellmoleküls mittlerer Größe mittels transienter Absorption, Fluorescence Upconversion und Anisotropie Spektroskopie untersucht. In Kooperation mit F. Santoro und R. Improta konnte eine detaillierte Beschreibung der ablaufenden Prozesse gefunden werden. In Übereinstimmung mit den von ihnen durchgeführten quantenmechanischen Simulationen hat sich herausgestellt, dass sich die Dynamik auf der ersten angeregten Potentialfläche nach der Anregung auf zwei Zeitskalen abspielt. Nach dem Passieren einer konische Durchschneidung isomerisiert das Molekül entweder zum thermodynamisch stabileren trans Isomer oder zu den instabileren Produktisomeren. An diesem System wurden nun adaptive Femtosekunden Quantenkontrollexperimente durchgeführt, mit dem Ziel den Isomerisierungsprozess zu beeinflussen. Es konnte erfolgreich gezeigt werden, dass die Isomerisierungseffizienz (die relative Menge von Edukt- zu Produktisomeren) sowohl erhöht als auch verringert werden kann. Einzel-Parameter Kontrollmechanismen wie zum Beispiel das Verwenden verschieden gechirpter Anregeimpulse oder unterschiedlicher Anregeimpulsenergien ergaben einen nur geringen Einfluss auf die Isomerisierungseffizienz. Diese Kontrollstudien über den Isomerisierungsprozess haben weiterführende Experimente an dem sehr komplexen biologischen System Retinal innerhalb des Proteins Bakteriorhodopsin motiviert. Die traditionelle Anrege-Abrege-Abfrage Technik wurde zu einem neuen Anrege-geformten-Abrege-Abfrage Konzept erweitert. Dadurch können molekulare Systeme in den Regionen der Potentialenergie-Landschaft kontrolliert werden, in denen der entscheidende Reaktionsschritt stattfinded. Verschiedene theoretische Berechnungen zum Problem der Erhöhung der Isomerisierungseffizienz stellen in Aussicht, dass Anrege-Abrege-Wiederanrege-Abfrage Mechanismen eine Möglichkeit der effektiven Beeinflussung der Reaktionsdynamik eröffnen. Mit der weiterentwickelten Methode können solche Vier-Puls-Techniken realisiert und ihr Einfluss auf den Reaktionsprozess systematisch untersucht werden. Zusätzlich wurde mittels Variation von parametrisierten spektralen Phasenfunktionen, wie verschiedene Ordnungen Chirp, die Dynamik des Abregungsprozesses beleuchtet. Durch Formen des Abregungsimpulses mittels adaptiver Femtosekunden Quantenkontrolle wurden die Informationen aus den systematische Untersuchung vervollständigt. Häufig sind die aus einem adaptiven Femtosekunden Quantenkontrollexperiment erhaltenen optimalen Laserimpulsformen sehr kompliziert. Besonders Anrege-Abrege Szenarien spielen oft eine wichtige Rolle in den ermittelten optimalen Lösungen und sollten daher gesondert untersucht werden. Dazu können verschiedenfarbige Doppelimpulse verwendet werden, bei denen man sowohl den Pulsabstand als auch die relative Amplitude oder die Phasendifferenz der beiden Einzellpulse systematisch ändert. Diese weiterentwickelte Methode wurde mittels einfacher Experimente charakterisiert. In einem weiteren Schritt wurde ein Aufbau entworfen, der Doppelimpulse erfordert, um ein maximale Ausbeute von Licht bei einer Wellenlänge von 266~nm zu erhalten. Mit dem Kontrollziel der maximalen dritten Harmonischen Ausbeute wurden adaptive Femtosekunden Quantenkontrollexperimente durchgeführt. Durch zusätzliche Messungen von verschiedenfarbigen Doppelimpuls-Kontrolllandschaften konnte die optimale Pulsform ermittelt und bestätigt werden. In einem abschließenden Experiment wurde die Abhängigkeit der Anregeeffizienz eines komplexen, in Methanol gelösten Farbstoffmoleküls auf verschiedene Impulsformen untersucht. Aus den Ergebnissen wird ersichtlich, dass sehr unterschiedliche Impulsformen ein Kontrollziel ähnlich gut erfüllen können. Verschiedenfarbige Doppelimpuls-Kontrolllandschaften können einen Einblick in Kontrollmechanismen von adaptiv gefundenen Impulsformen ermöglichen und Informationen über die Reaktionsdynamik liefern. Mittels der angewandten und weiterentwickelten Methoden mehr über verschiedene Prozesse unterschiedlicher Molekülklassen zu lernen ist ein viel versprechendes und realistisches Ziel für die Zukunft. Die präsentierten Experimente zeigen, dass es möglich ist, geometrische Änderungsreaktionen in chemisch und biologisch relevanten Systemen durch adaptive Femtosekunden Quantenkontrolle zu steuern. N2 - The formation of different isomers by rearrangement of the molecular structure plays a substantial role in many areas in physics, chemistry and biology. The control of such reactions is therefore a very appealing task. Directly connected to the control is the observation and characterization of the dynamics. Within the last years, adaptive femtosecond quantum control has proven to be a very powerful tool to control chemical reactions. Prototype experiments based on simple reactions already have shown that the concept of femtosecond quantum control is also applicable for molecules in a condensed environment. This thesis deals with the observation and control of such isomerization reactions in chemically and biologically relevant systems. Therefore the reaction dynamics of a medium size prototype molecule of the family of the cyanine dyes in solution were investigated by transient absorption spectroscopy, by fluorescence upconversion and by anisotropy spectroscopy. In cooperation with F. Santoro and R. Improta a detailed and reliable description of the overall kinetics was achieved, evidencing a two-timescale dynamics on the first excited potential energy surface after excitation. After decaying through a conical intersection, the molecule isomerizes either to the thermodynamically most stable trans isomer or to two less stable product isomers. Adaptive femtosecond quantum control experiments were performed on this system with the objective to control the isomerization process. Both enhancement as well as reduction of the isomerization efficiency, i.e the relative yield of the educt to the product isomers, were achieved. Single parameter control mechanisms such as applying different chirps or varying the excitation laser pulse energy failed to change the ratio of the photoproducts. These control studies on the isomerization process of a medium size molecule in the condensed phase motivated experiments on the very complex biological system of retinal embedded in bacteriorhodopsin. The traditional pump-dump-probe method was extended to a new pump-shaped-dump-probe scheme to control molecular systems in those regions of the potential-energy landscape where the decisive reaction step occurs. Different theoretical simulations on the enhancement of the isomerization yield predict that pump-dump-repump-probe mechanisms can control the reaction dynamics. Using the novel scheme, such a four-pulse technique with a double-pulse-like shaped dump pulse can be realized and its impact on the reaction process can be systematically investigated. With further parameterized scans of specialized phase functions, such as different orders of chirp, the dynamics of the dumping process has been illuminated. Finally by adaptively shaping the dump pulse the information from the systematic scan has been refined and completed. Very often, adaptively obtained optimal laser pulse shapes are very complicated and can contain structures, that contribute to a certain control mechanism to different degrees. Consequently, it can be difficult to identify the control mechanism of such optimal pulses. Especially pump-dump scenarios often play an important role in the acquired optimal solution and therefore deserve to be investigated separately. For this, colored double pulses are employed and both the pulse separation and the relative amplitude or phase difference of the two subpulses are systematically scanned. This further developed method was first characterized by simple experiments. Then, a setup forcing double-pulses to obtain the highest third harmonic yield was designed. The control objective of maximizing the third harmonic yield has the advantage that the optimal pulse shape can be calculated and intuitively understood. Adaptive femtosecond quantum control experiments were performed with this control objective. With additional measurements of colored double-pulse control landscapes the control mechanism of the adaptively obtained optimal pulse shape can be extracted and confirmed. In a further experiment, the dependence of the excitation efficiency of a complex dye molecule dissolved in methanol on selected pulse shapes probed by transient absorption spectroscopy was studied. The results show that very different pulse shapes are equally adequate to fulfill the control objective. Colored double pulse scans thus can give an insight into the control mechanism of adaptively obtained pulse shapes and provide information about reaction dynamics. Investigations on various processes of different molecular classes using the methods developed and applied here are a promising and realistic goal for the near future. The presented experiments demonstrate a successful manipulation of geometrical rearrangement reactions in chemically and biologically relevant systems by adaptive femtosecond quantum control. KW - Molekül KW - Isomerisierungsreaktion KW - Ultrakurzer Lichtimpuls KW - Femtosekundenbereich KW - Adaptivregelung KW - Isomerizierung KW - Quantenkontrolle KW - transiente Absorption KW - kondensierte Phase KW - flüssige Phase KW - isomerization KW - quantum control KW - transiente absorption spectroscopy KW - condensed phase KW - liquid phase Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-20222 ER - TY - THES A1 - Vogel, Patrick T1 - Traveling Wave Magnetic Particle Imaging T1 - Traveling Wave Magnetic Particle Imaging N2 - Magnetic Particle Imaging (MPI) ist eine noch sehr junge Technologie unter den nicht-invasiven tomographischen Verfahren. Seit der ersten Veröffentlichung 2005 wurden einige Scannertypen und Konzepte vorgestellt, welche durch die Messung des Antwortsignals von superparamagnetischen Eisennanopartikeln (SPIOs) auf wechselnde Magnetfelder ein dreidi-mensionales Bild ihrer Verteilung berechnen können. Durch die direkte Messung des Tracers handelt es sich beim MPI um eine sehr sensitive und hochspezifische bildgebende Methode. Zu Beginn dieser Forschungsarbeit gab es nur wenige bekannte MPI-Scanner, die jedoch alle ein nur kleines Field-of-View (FOV) vorweisen konnten. Der Grund dafür liegt in der Ver-wendung von Permanentmagneten. Das Ziel war es nun, ein neues Konzept auszuarbeiten und einen 3D-MPI-Scanner zu entwer-fen, der in der Lage ist, ein mausgroßes Objekt zu messen. In dieser Arbeit wird ein alternatives Scannerkonzept für die dreidimensionale Bildge-bung superparamagnetischer Eisennanopartikel vorgestellt. Der Traveling Wave MPI-Scanner (TWMPI) basiert auf einem neu entwickelten Hauptspulensystem, welches aus mehreren Elektromagneten besteht. Dadurch ist die Hardware bereits in der Lage, eine Linie entlang der Symmetrieachse über einen großen Bereich dynamisch zu kodieren. Mit Hilfe weiterer Ab-lenkspulen kann schließlich ein FOV von 65 x 25 x 25 Millimetern dreidimensional abgetastet werden. Dazu stehen mehrere Scanverfahren zur Verfügung, welche das Probenvolumen li-nienweise oder ebenenweise abtasten und mit einer Auflösung von ca. 2 Millimetern die Ver-teilung der SPIOs in wenigen Millisekunden abbilden können. Mit diesem neuen Hardwareansatz konnte erstmals ein MPI-Scanner mit einem MR-Tomographen (MRT) kombiniert werden. Das MPI/MRT-Hybridsystem liefert tomographi-sche Bilder des Gewebes (MRT) und zeigt die Verteilung des eisenhaltigen Kontrastmittels (MPI), ohne die Probe bewegen zu müssen. In einer in-vivo Echtzeitmessung konnte der TWMPI-Scanner mit 20 Bildern pro Se-kunde die dynamische Verteilung eines eisenhaltigen Kontrastmittels im Körper und speziell im schlagenden Herzen eines Tieres darstellen. Diese Echtzeitfähigkeit eröffnet in der kardi-ovaskuläre Bildgebung neue Möglichkeiten. Erste Messungen mit funktionalisierten Eisenpartikeln zeigen die spezifische Bildge-bung verschiedener Zelltypen und stellen einen interessanten Aspekt für die molekulare Bild-gebung dar. Die Sensitivität des Scanners liegt dabei im Bereich von wenigen Mikrogramm Eisen pro Milliliter, was für den Nachweis von wenigen 10.000 mit Eisen markierten Zellen ausreicht. Neben Messungen an diversen Ferrofluiden und eisenhaltigen Kontrastmitteln konnte der Einfluss von massiven Materialen, wie Eisenstückchen oder Eisenspänen, auf die rekon-struierten Bilder untersucht werden. Erste Messungen an Gestein zeigen die Verteilung von Eiseneinschlüssen und bieten die Möglichkeit einer weiteren zerstörungsfreien Untersuchungsmethode für Materialwissen-schaftler und Geologen. Weiterführende Testmessungen mit einer unabhängigen μMPI-Anlage zeigen erste Ergebnisse mit Auflösungen im Mikrometerbereich und liefern Erkennt-nisse für den Umgang und Messung mit starken Gradientenfeldern. Eine Modifizierung der Messanlage erlaubt es, in gerade einmal 500 μs ein komplettes Bild aufzunehmen, womit die Bewegung eines Ferrofluidtropfens in Wasser sichtbar gemacht werden konnte. Damit ist diese TWMPI-Anlage das schnellste MPI-System und eröffnet die Möglichkeit grundlegende Erfahrungen in der Partikeldynamik zu erlangen. Der vorgestellte Traveling Wave MPI-Scanner ist ein alternativer Scannertyp, welcher sich von anderen MPI-Scannern abhebt. Mit neuen Ansätzen ist in der Lage ein mausgroßes Objekt auf dynamische Weise sehr schnell abzutasten. Dabei konnten in verschiedenen Mes-sungen die Funktionalität und Leistungsfähigkeit des TWMPI-Konzeptes demonstriert wer-den, welche die gesteckten Ziele deutlich übertreffen. N2 - Magnetic particle imaging (MPI) is still a very young technology among the non-invasive tomographic modalities. Since its first publication in 2005, several types of scanners and concepts were presented, which can reconstruct a three-dimensional image of the distri-bution of superparamagnetic iron-oxide nanoparticles (SPIOs) by measuring their magnetiza-tion response to varying magnetic fields. Due to the direct measurement of the tracer MPI is a very sensitive and highly specific imaging modality. At the beginning of this project only a few MPI-scanners were known, but all of them are limited to a small field-of-view (FOV). The reason for this is the use of permanent mag-nets. The aim of this work was to develop a new concept and design for a 3D-MPI-scanner, which is able to measure a mouse sized object. In this thesis an alternative scanner concept for three-dimensional imaging of super-paramagnetic iron nanoparticles is presented. The Traveling Wave-MPI-scanner (TWMPI) is based on a newly developed main coil system, which consists of a series of electromagnets. This coil array is by itself able to dynamically encode a line along the symmetry axis over an extended length. With additional offset coils the system is able to scan a FOV of 65 x 25 x 25 millimeters in three dimensions. For scanning the whole volume several tech-niques are available, which map the data line-by-line or slice-by-slice in a few milliseconds and yield the distribution of SPIOs with a resolution of about 2 millimeters. Using this new hardware approach a MPI-scanner was successfully combined with an MRI-scanner for the first time. The MPI/MRI-hybrid-system provides tomographic images of the tissue (MRI) and detects the distribution of iron-containing contrast agent (MPI), without the need to move the sample. In an in-vivo real-time measurement using the TWMPI-scanner the dynamic distribu-tion of an iron-containing contrast agent was visualized in the body and especially in the beat-ing heart of an animal with a temporal resolution of 20 frames per second. This real-time ca-pability opens up new possibilities in cardio-vascular imaging. First measurements using functionalized iron-oxide nanoparticles specifically detect different cell types and thereby provide an interesting aspect for molecular imaging. The sensi-tivity of the scanner is in the range of a few micrograms of iron per milliliter, which is suffi-cient to detect about 50,000 iron-labeled cells. In several studies the influence of various ferrofluids, iron-containing contrast agents and solid materials, such as pieces of iron or iron filings, were examined on the reconstructed images. First measurements on ferrous rock show the location of iron-inclusions and offer an-other non-destructive imaging technique for material scientists and geologists. Additional tests with an independent μMPI-system were performed to explore resolutions in the micrometer range and provide insights for handling and measuring with a high gradient strength. A modification of the setup allows to acquire a full slice in just 500 microseconds, which enable the visualization of the motion of a droplet of ferrofluid in water. With this TWMPI is the fastest MPI-system available and gives access to fundamental studies of particle dynamics. The presented Traveling Wave MPI-system is an alternative scanner concept, which sets itself apart from other MPI-scanners. Mouse-sized objects can be imaged in a dynamic way in very short times. The feasibility and performance of the TWMPI-concept were suc-cessfully demonstrated in various measurements considerably exceeding the original aims. KW - Magnetpartikelbildgebung KW - Traveling Wave Magnetic Particle Imaging KW - Traveling Wave Magnetic Particle Imaging KW - tomographic imaging method KW - molecular imaging KW - field free point (FFP) KW - Tomografie Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-132700 ER - TY - THES A1 - Unsleber, Sebastian Philipp T1 - Festkörperbasierte Einzelphotonenquellen als Grundbausteine der Quanteninformationstechnologie T1 - Solid-state single photon sources as building blocks for the quantum information technology N2 - Die vorliegende Arbeit hatte das Ziel basierend auf Halbleiternanostrukturen eine effiziente und skalierbare Quelle einzelner und ununterscheidbarer Photonen zu entwickeln. Dies ist eine Basiskomponente von zukünftigen quantenphysikalischen Anwendungen wie der Quantenkommunikation oder dem Quantencomputer. Diese Konzepte nutzen gezielt quantenmechanische Systeme um einerseits Kommunikation absolut abhörsicher zu machen oder um neuartige Computer zu konstruieren, die bestimmte Aufgaben - wie die Produktzerlegung großer Zahlen - effizienter lösen als heutige Systeme. Ein mögliche Realisierung der Quantenkommunikation ist beispielsweise die Schlüsselverteilung zwischen zwei Parteien durch Verwendung des BB84-Protokolls. Dazu wird eine Lichtquelle benötigt, welche die physikalisch kleinstmögliche Lichtmenge - ein einzelnes Photon - aussendet. Der Kommunikationskanal wird dann über verschiedene Polarisationszustände dieser Photonen gegen ein Abhören nach außen hin abgesichert. Da die maximale Kommunikationsdistanz aufgrund von Verlusten im Quantenkanal beschränkt ist, muss das Signal für größere Distanzen mit Hilfe eines sog. Quantenrepeaters aufbereitet werden. Ein solcher kann ebenfalls unter Verwendung von Einzelphotonenquellen realisiert werden. Das Konzept des Quantenverstärkers stellt aber die zusätzliche Anforderung an die Einzelphotonenquelle, dass die ausgesendeten Lichtteilchen in der Summe ihrer Eigenschaften wie Energie und Polarisation immer gleich und somit ununterscheidbar sein müssen. Auf Basis solcher ununterscheidbarer Photonen gibt es zudem mit dem linear optischen Quantenrechner auch mögliche theoretische Ansätze zur Realisierung eines Quantencomputers. Dabei kann über die Quanteninterferenz von ununterscheidbaren Photonen an optischen Bauteilen wie Strahlteilern ein Quanten-NOT-Gatter zur Berechnung spezieller Algorithmen realisiert werden. Als vielversprechende Kandidaten für eine solche Lichtquelle einzelner Photonen haben sich in den letzten Jahren Halbleiter-Quantenpunkte herauskristallisiert. Dank des festkörperbasierten Ansatzes können diese Strukturen in komplexe photonische Umgebungen zur Erhöhung der Photonen-Extraktionseffizienz und -Emissionsrate eingebettet werden. Ziel dieser Arbeit war somit eine effiziente Quelle einzelner ununterscheidbarer Photonen zu realisieren. Im Hinblick auf die spätere Anwendbarkeit wurde der Fokus zudem auf die skalierbare bzw. deterministische Fabrikation der Quantenpunkt-Strukturen gelegt und zwei technologische Ansätze - die kryogene in-situ-Lithographie und das positionierte Wachstum von Quantenpunkten - untersucht. Im ersten experimentellen Kapitel dieser Arbeit wird ein neuartiges Materialsystem vorgestellt, welches sich zur Generation einzelner Photonen eignet. Es können spektral scharfe Emissionslinien mit Linienbreiten bis knapp über 50 µeV aus Al$_{0,48}$In$_{0,52}$As Volumenmaterial beobachtet werden, wenn diese Schicht auf InP(111) Substraten abgeschieden wird. In Querschnitt-Rastertunnelmikroskopie-Messungen wurden ca. 16 nm große Cluster, welche eine um ungefähr 7 % höhere Indiumkonzentration im Vergleich zur nominellen Zusammensetzung des Volumenmaterials besitzen, gefunden. Über die Simulation dieser Strukturen konnten diese als Quelle der spektral scharfen Emissionslinien identifiziert werden. Zudem wurde mittels Auto- und Kreuzkorrelationsmessungen nachgewiesen, dass diese Nanocluster einzelne Photonen emittieren und verschieden geladene exzitonische und biexzitonische Ladungsträgerkomplexe binden können. Anschließend wurde der Fokus auf InGaAs-Quantenpunkte gelegt und zunächst im Rahmen einer experimentellen und theoretischen Gemeinschaftsarbeit die Kohärenzeigenschaften eines gekoppelten Quantenpunkt-Mikrokavität-Systems untersucht. Über temperaturabhängige Zwei-Photonen Interferenz Messungen und dem Vergleich mit einem mikroskopischen Modell des Systems konnten gezielt die Bestandteile der Quantenpunkt-Dephasierung extrahiert werden. Auf diesen Ergebnissen aufbauend wurde die gepulste, strikt resonante Anregung von Quantenpunkten als experimentelle Schlüsseltechnik etabliert. Damit konnten bei tiefen Temperaturen nahezu vollständig ununterscheidbare Photonen durch eine Zwei-Photonen Interferenz Visibilität von über 98 % nachgewiesen werden. Für ein skalierbares und deterministisches Quantenpunkt-Bauelement ist entweder die Kontrolle über die Position an welcher der Quantenpunkt gewachsen wird nötig, oder die Position an der eine Mikrokavität geätzt wird muss auf die Position eines selbstorganisiert gewachsenen Quantenpunktes abgestimmt werden. Im weiteren Verlauf werden Untersuchungen an beiden technologischen Ansätzen durchgeführt. Zunächst wurde der Fokus auf positionierte Quantenpunkte gelegt. Mittels in das Substrat geätzter Nanolöcher wird der Ort der Quantenpunkt-Nukleation festgelegt. Durch die geätzten Grenzflächen in Quantenpunkt-Nähe entstehen jedoch auch Defektzustände, die negativen Einfluss auf die Kohärenz der Quantenpunkt-Emission nehmen. Deshalb wurde an diesem Typus von Quantenpunkten die strikt resonante Anregung etabliert und zum ersten Mal die kohärente Kopplung des Exzitons an ein resonantes Lichtfeld demonstriert. Zudem konnte die deterministische Kontrolle der Exzitonbesetzung über den Nachweis einer Rabi-Oszillation gezeigt werden. Abschließend wird das Konzept der kryogenen in-situ-Lithographie vorgestellt. Diese erlaubt die laterale Ausrichtung der Mikrokavität an die Position eines selbstorganisiert gewachsenen Quantenpunktes. Damit konnte gezielt die Emission eines zuvor ausgewählten, spektral schmalen Quantenpunktes mit nahezu 75 % Gesamteffizienz eingesammelt werden. Die Ununterscheidbarkeit der Quantenpunkt-Photonen war dabei mit einer Zwei-Photonen Interferenz Visibilität von bis zu $\nu=(88\pm3)~\%$ sehr hoch. Damit wurde im Rahmen dieser Arbeit eine Einzelphotonenquelle realisiert, aus der sich sehr effizient kohärente Photonen auskoppeln lassen, was einen wichtigen Schritt hin zur deterministischen Fabrikation von Lichtquellen für quantenphysikalischen Anwendungen darstellt. N2 - The aim of this thesis was to develop an efficient and scalable source of single and indistinguishable photons. This is a fundamental element of future quantum physical applications like quantum communication or quantum networks. These concepts use quantum mechanical systems to either establish absolute secure communication or to construct new computers, whose calculating capacity for specialized algorithms - like integer factorization - is far beyond today's systems. One possible realization of quantum communication is the key distribution between two parties via using the BB84-protocol. This scheme needs a lights source that emits the physical smallest amount of light - a single photon. The communication channel between transmitter and receiver is then secured against eavesdropping by different polarisation states of these photons. The non-avoidable loses in the quantum channel limit the maximum possible communication distance, which is why the signal has to be amplified with a so called quantum repeater after a certain distance. Such a repeater can also be realized with a single photon source. In addition to the BB84-protocol, for realizing the concept of a quantum repeater the photons have to share all their properties like energy and polarization, i. e. they need to be indistinguishable. Over the past years, semiconductor quantum dots have been identified as a promising candidate for such a light source. Due to the solid state scheme, these structures can be implemented into complex photonic architectures to increase the outcoupling efficiency and the emission rate of single photons. The main goal of the following work was therefore the realization of an efficient source of single and indistinguishable photons. Keeping future applications in mind, the additional focus of this work was lying on the scalable and deterministic fabrication of these quantum dot structures and two technological approaches - the cryogenic in-situ-lithography and the positioned growth of quantum dots - were investigated. In the first part of this thesis, a novel material system, which serves as a source of single photons is presented. Spectrally sharp emission features with a linewidth down to 50 µeV from bulk Al$_{0,48}$In$_{0,52}$As grown on InP(111) substrates were observed. Via cross-section scanning tunneling microscopy measurements, nanoclusters with a diameter of approximately 16 nm and a 7 % increased indium concentration compared to the nominal composition, were found. Additional simulations of these complexes identify these nanoclusters as sources of the spectrally sharp emissions lines. Furthermore, single photon emission as well as the formation of multi excitonic charge complexes within these clusters via auto- and crosscorrelation measurements is confirmed. Afterwards, the work focusses on InGaAs-quantum dots and, as a first step, the coherence properties of a coupled quantum dot microcavity system are investigated within a joint theoretical and experimental work. Via temperature dependent two-photon interference measurements the single dephasing mechanisms of this system are extracted via modelling the results with a microscopic theory. Based on this results, the strict resonant excitation of quantum dots was established as a experimental key technique and quantum dot photons with a two-photon interference visibility above 98 % were generated at low temperatures. For scalable and deterministic quantum dot devices, one either needs to control the growth spot of a quantum dot or the position of an etched microcavity has to be aligned to the position of a self-organized quantum dot. In the subsequent parts if this work, studies on both technological approaches are presented. First, spectroscopic experiments on site controlled quantum dots were carried out. Via etched nanoholes, the nucleation spot of the quantum dot is defined. These etched surfaces may lead to defect states, which decrease the coherence of the quantum dot emission. In order to avoid these detrimental influence, the strict resonant excitation of such site controlled quantum dots is established and the coherent coupling of the site controlled quantum dot exciton to the resonant laser field is observed. In addition, deterministic control of the site controlled quantum dot population is achieved, which is verified via the observation of the first Rabi-oscillation. Finally, the so-called in-situ-lithography is presented, which allows for the lateral alignment of a self-organized quantum dot and the fundamental mode of a micropillar. Using this technique, an overall collection efficiency of single photons from a pre-selected quantum dot with a small linewidth of almost 75 % is shown. The coherence of this quantum dot was notably, which is demonstrated by a two-photon interference visibility as high as $\nu=(88\pm3)~\%$. In summary, an efficient source of single and indistinguishable photons was realized in this thesis, which is an important step towards the fabrication of deterministic quantum dot devices for quantum mechanical applications. KW - Quantenpunkt KW - Einzelphotonenemission KW - Quantenkommunikation KW - Einzelphotonenquelle KW - Mikrosäulenresonator KW - Nichtunterscheidbarkeit KW - Verteilte Bragg-Reflexion KW - Optischer Resonator Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-147322 ER - TY - THES A1 - Ullherr, Maximilian T1 - Optimization of Image Quality in High-Resolution X-Ray Imaging T1 - Optimierung von Bildqualität in der hochauflösenden Röntgenbildgebung N2 - The SNR spectra model and measurement method developed in this work yield reliable application-specific optima for image quality. This optimization can either be used to understand image quality, find out how to build a good imaging device or to (automatically) optimize the parameters of an existing setup. SNR spectra are here defined as a fraction of power spectra instead of a product of device properties. In combination with the newly developed measurement method for this definition, a close correspondence be- tween theory and measurement is achieved. Prior approaches suffer from a focus on theoretical definitions without fully considering if the defined quantities can be measured correctly. Additionally, discrepancies between assumptions and reality are common. The new approach is more reliable and complete, but also more difficult to evaluate and interpret. The signal power spectrum in the numerator of this fraction allows to model the image quality of different contrast mechanisms that are used in high-resolution x-ray imaging. Superposition equations derived for signal and noise enable understanding how polychromaticity (or superposition in general) affects the image quality. For the concept of detection energy weighting, a quantitative model for how it affects im- age quality was found. It was shown that—depending on sample properties—not detecting x-ray photons can increase image quality. For optimal computational energy weighting, more general formula for the optimal weight was found. In addition to the signal strength, it includes noise and modulation transfer. The novel method for measuring SNR spectra makes it possible to experimentally optimize image quality for different contrast mechanisms. This method uses one simple measurement to obtain a measure for im- age quality for a specific experimental setup. Comparable measurement methods typically require at least three more complex measurements, where the combination may then give a false result. SNR spectra measurements can be used to: • Test theoretical predictions about image quality optima. • Optimize image quality for a specific application. • Find new mechanisms to improve image quality. The last item reveals an important limitation of x- ray imaging in general: The achievable image quality is limited by the amount of x-ray photons interacting with the sample, not by the amount incident per detector area (see section 3.6). If the rest of the imaging geometry is fixed, moving the detector only changes the field of view, not the image quality. A practical consequence is that moving the sample closer to the x-ray source increases image quality quadratically. The results of a SNR spectra measurement represent the image quality only on a relative scale, but very reliable. This relative scale is sufficient for an optimization problem. Physical effects are often already clearly identifiable by the shape of the functional relationship between input parameter and measurement result. SNR spectra as a quantity are not well suited for standardization, but instead allow a reliable optimization. Not satisfying the requirements of standardization allows to use methods which have other advantages. In this case, the SNR spectra method describes the image quality for a specific application. Consequently, additional physical effects can be taken into account. Additionally, the measurement method can be used to automate the setting of optimal machine parameters. The newly proposed image quality measure detection effectiveness is better suited for standardization or setup comparison. This quantity is very similar to measures from other publications (e.g. CNR(u)), when interpreted monochromatically. Polychromatic effects can only be modeled fully by the DE(u). The measurement processes of both are different and the DE(u) is fundamentally more reliable. Information technology and digital data processing make it possible to determine SNR spectra from a mea- sured image series. This measurement process was designed from the ground up to use these technical capabilities. Often, information technology is only used to make processes easier and more exact. Here, the whole measurement method would be infeasible without it. As this example shows, using the capabilities of digital data processing much more extensively opens many new possibilities. Information technology can be used to extract information from measured data in ways that analog data processing simply cannot. The original purpose of the SNR spectra optimization theory and methods was to optimize high resolution x-ray imaging only. During the course of this work, it has become clear that some of the results of this work affect x-ray imaging in general. In the future, these results could be applied to MI and NDT x-ray imaging. Future work on the same topic will also need to consider the relationship between SNR spectra or DE(u) and sufficient image quality.This question is about the minimal image quality required for a specific measurement task. N2 - Das in dieser Arbeit entwickelte Modell und die Messmethode für SNR Spektren ergeben zuverlässige anwendungsspezifische Optima für die Bildqualität. Diese Optimierung kann verwendet werden, entweder um Bildqualität zu verstehen, um herauszufinden wie ein gutes Bildgebungsgerät gebaut werden kann oder um die Parameter eines existierenden Aufbaus (automatisch) festzulegen. ... KW - Bildqualität KW - Bildgebendes Verfahren KW - Computertomografie KW - x-ray imaging KW - x-ray microscopy KW - image quality KW - signal to noise ratio KW - computed tomography KW - x-ray inline phase contrast Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-231171 ER - TY - THES A1 - Tuchscherer, Philip T1 - A Route to Optical Spectroscopy on the Nanoscale T1 - Über Optische Spektroskopie auf der Nanoskala N2 - Time-resolved optical spectroscopy has become an important tool to investigate the dynamics of quantum mechanical processes in matter. In typical applications, a first “pump” pulse excites the system under investigation from the thermal equilibrium to an excited state, and a second variable time-delayed “probe” pulse then maps the dynamics of the excited system. Although advanced nonlinear techniques have been developed to investigate, e.g., coherent quantum effects, all of these techniques are limited in their spatial resolution. The laser focus diameter has a lower bound given by Abbe’s diffraction limit, which is roughly half the optical excitation wavelength—corresponding to about 400nm in the presented experiments. In the time-resolved experiments that have been suggested so far, averaging over the sample volume within this focus cannot be avoided. In this thesis, two approaches were developed to overcome the diffraction limit in optical spectroscopy and to enable the investigation of coherent processes on the nanoscale. In the first approach, analytic solutions were found to calculate optimal polarizationshaped laser pulses that provide optical near-field pump–probe pulse sequences in the vicinity of a nanostructure. These near-field pulse sequences were designed to allow excitation of a quantum system at one specific position at a certain time and probing at a different position at a later time. In the second approach, the concept of coherent two-dimensional (2D) spectroscopy, which has had great impact on the investigation of coherent quantum effects in recent years, was combined with photoemission electron microscopy, which yields a spatial resolution well below the optical diffraction limit. Using the analytic solutions, optical near fields were investigated in terms of spectroscopic applications. Near fields that are excited with polarization-shaped femtosecond laser pulses in the vicinity of appropriate nanostructures feature two properties that are especially interesting in the view of spectroscopic applications: On the one hand, control of the spatial distribution of the optical fields is achieved on the order of nanometers. On the other hand, the temporal evolution of these fields can be adjusted on the order of femtoseconds. In this thesis, solutions were found to calculate the optimal polarizationshaped laser pulses that control the near field in a general manner. The main idea to achieve this deterministic control was to disentangle the spatial and temporal near-field control. First, the spatial distribution of the optical near field was controlled by assigning the correct state of polarization for each frequency within the polarization-shaped laser pulse independently. The remaining total phase—not employed for spatial control—was then used for temporal near-field compression, which, in experimental applications, would lead to an enhancement of the nonlinear signal at the respective location. In contrast to the use of optical near fields, where pump–probe sequences themselves are localized below the diffraction limit and the detection does not have to provide the spatial resolution, a different approach was suggested in this thesis to gain spectroscopic information on the nanoscale. The new method was termed “Coherent two-dimensional (2D) nanoscopy” and transfers the concept of “conventional” coherent 2D spectroscopy to photoemission electron microscopy. The pulse sequences used for the investigation of quantum systems in this method are still limited by diffraction. However, the new key concept is to detect locally generated photoelectrons instead of optical signals. This yields a spatial resolution that is well below the optical diffraction limit. In “conventional” 2D spectroscopy a triple-pulse sequence initiates a four wave mixing process that creates a coherence. In a quantum mechanical process, this coherence is converted into a population by emission of an electric field, which is measured in the experiment. Contrarily, in the developed 2D nanoscopy, four-wave mixing is initiated by a quadruple-pulse sequence, which leaves the quantum system in an electronic population. This electronic population carries coherent information about the investigated quantum system and can be mapped with a spatial resolution down to a few nanometers given by the spatial resolution of the photoemission electron microscope. Hence, 2D nanoscopy can be considered a generalization of time-resolved photoemission experiments. In the future, it may be of similar beneficial value for the field of photoemission research as “conventional” 2D spectroscopy has proven to be for optical spectroscopy and nuclear magnetic resonance experiments. In a first experimental implementation of coherent 2D nanoscopy coherent processes on a corrugated silver surface were measured and unexpected long coherence lifetimes could be determined. N2 - Zur Untersuchung von Dynamiken quantenmechanischer Prozesse in Materie hat sich die zeitaufgelöste optische Spektroskopie zu einem zentralen Werkzeug entwickelt. Eine Standardmethode ist hierbei die Anrege-Abfrage-Spektroskopie. Bei solch einem Experiment wird das zu untersuchende System zunächst mit einem Anregepuls aus dem thermischen Gleichgewicht in einen höheren Zustand angeregt. Anschließend untersucht man mit einem zweiten zeitverzögerten Abfragepuls die Dynamik des angeregten Systems. Obwohl fortgeschrittene experimentelle Methoden entwickelt wurden um kohärente Quanteneffekte zu untersuchen, sind all diese Experimente nach wie vor in ihrer räumlichen Auflösung begrenzt. Aufgrund von Beugung ist der Fokus eines Laserstrahls limitiert. Diese untere Grenze ist durch Abbe’s Auflösungsgrenze gegeben und entspricht etwa der Hälfte der optischen Anregungswellenlänge, d.h. etwa 400nm in den hier vorgestellten Experimenten. Daher kann eine Mittelung über das Probenvolumen, gegeben durch die Fokusgröße, in den bisher vorgestellten Experimenten nicht vermieden werden. In dieser Arbeit wurden zwei Ansätze verfolgt, um die Beugungsgrenze in der optischen Spektroskopie zu überwinden und die Untersuchung von kohärenten Prozessen auf der Nanometerskala zu ermöglichen. Im ersten Ansatz wurden analytische Lösungen gefunden, um optimal polarisationsgeformte Laserpulse zu berechnen, die optische Anrege-Abfrage-Nahfeld-Pulsfolgen in der Nähe einer Nanostruktur ermöglichen. Diese Nahfeld-Pulsfolgen wurden entwickelt, um ein quantenmechanisches System an einer bestimmten Position zu einem bestimmten Zeitpunkt anzuregen und an einer anderen Position zu einem späteren Zeitpunkt abzufragen. Im zweiten Ansatz wurde das Konzept der kohärenten zweidimensionalen (2D) Spektroskopie, die in den letzten Jahren großen Einfluss auf die Untersuchung von kohärenten Quanteneffekten gehabt hat, mit Photoelektronenmikroskopie kombiniert. Letztere ermöglicht eine räumliche Auflösung deutlich unter der optischen Auflösungsgrenze. Mit Hilfe der analytischen Lösungen wurden optische Nahfelder in Bezug auf spektroskopische Anwendungen untersucht. Nahfelder, die mit polarisationsgeformten Femtosekunden-Laserpulsen in der Nähe von entsprechenden Nanostrukturen angeregt werden, verfügen über zwei Eigenschaften, die besonders interessant für spektroskopische Anwendungen sind: Zum einen kann die räumliche Verteilung der optischen Felder auf der Größenordnung von Nanometern kontrolliert werden. Zum anderen kann die zeitliche Entwicklung dieser Felder in der Größenordnung von Femtosekunden manipuliert werden. In dieser Arbeit wurden Lösungen gefunden, um optimale polarisationsgeformte Laserpulse zu berechnen, die diese Nahfeld-Steuerung in einer allgemeinen Art und Weise erlauben. Die Hauptidee, um diese deterministische Steuerung zu erreichen, war die räumliche und zeitliche Nahfeld-Kontrolle zu entkoppeln. Zuerst wurde dafür die räumliche Verteilung der optischen Nahfelder durch die Zuordnung des korrekten Polarisationszustandes für jede Frequenz, innerhalb des polarisationsgeformten Laserpulses, unabhängig gesteuert. Die verbleibende totale Phase, die nicht für die räumliche Kontrolle benötigt wird, wurde dann verwendet um den nichtlinearen Fluss an den gewünschten Positionen durch zeitliche Nahfeldkomprimierung zu erhöhen. Im Gegensatz zur Verwendung von optischen Nahfeldern, in der die Anrege-Abfrage-Nahfeld-Pulsfolgen selbst unter dem Beugungslimit lokalisiert sind und die Detektion nicht räumlich aufgelöst sein muss, wurde in dieser Arbeit noch ein anderer Ansatz vorgeschlagen, um spektroskopische Informationen auf der Nanometerskala zu erhalten. Die neue Methode wurde als „kohärente zweidimensionale (2D) Nanoskopie“ beschrieben und überträgt das Konzept der „herkömmlichen“ kohärenten 2D Spektroskopie auf die Photoemissionselektronenmikroskopie. In dieser neuen Methode ist die räumliche Auflösung der zur Untersuchung des quantenmechanischen Sytems erforderlichen Pulssequenzen zwar durch Beugung begrenzt. Die wesentliche Neuerung ist allerdings, lokal erzeugte Photoelektronen anstelle von optischen Signalen zu messen. Daraus ergibt sich eine räumliche Auflösung, die weit unterhalb der optischen Beugungsgrenze liegt. Die photoemittierten Elektronen tragen dann kohärente Information über das untersuchte System und können mit einer räumlichen Auflösung von wenigen Nanometern abgebildet werden. Die Auflösung ist dabei durch das verwendete Photoemissionsmikroskop vorgegeben. Demzufolge kann 2D Nanoskopie als eine Verallgemeinerung der zeitaufgelösten Photoemissionsexperimente gesehen werden. In einer ersten experimentellen Umsetzung der kohärenten 2D Nanoskopie wurden kohärente Prozesse auf einer rauhen Silberoberfläche untersucht und dabei unerwartet langlebige Kohärenzen gemessen. KW - Ultrakurzzeitspektroskopie KW - Kohärente Optik KW - Ultrakurzzeit Spektroskopie KW - Kohärente 2D Spektroskopie KW - Coherent 2D Spectroscopy KW - Nanooptic KW - Ultrafast spectroscopy KW - Surface plasmons KW - Optische Spektroskopie KW - Nahfeldoptik KW - Oberflächenplasmonresonanz Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-72228 ER - TY - THES A1 - Triphan, Simon T1 - T1 und T2*-Quantifizierung in der menschlichen Lunge T1 - T1 and T2* quantification in the human lung N2 - In dieser Arbeit werden für die Anwendung in der menschlichen Lunge optimierte Methoden zur Bestimmung von T1- und T2*-Karten diskutiert: Dc-Gating ermöglicht die Quantifizierung in freier Atmung, wobei für die T1-Quantifizierung mittels Inversion Recovery eine Korrektur des dc-Signals entwickelt wurde. Dies hat den Vorteil, dass Parameterkarten aus mehreren Messungen anhand ihrer dc-Signale passend überlagert werden können. Da T1 und T2* auf unterschiedliche Art und Weise von der Sauerstoffkonzentration abhängen, verbessert dies die Möglichkeit, ΔT1- und ΔT2*- Differenzkarten aus Messungen mit unterschiedlichen O2-Konzentrationen im Atemgas zu erstellen. Die Parameterquantifizierung ist in erster Linie für die Beobachtung von Krankheitsverläufen interessant, da T1 und T2* absolute, vergleichbare Zahlen sind. Da T2* deutlich vom Atemzustand abhängt, ist es auch hierfür sinnvoll, durch Gating identische Atemzustände abzubilden. Um die unterschiedlichen Einflüsse des Sauerstoffs auf T1 und T2* besser vergleichbar zu machen, wurde in dieser Arbeit weiterhin eine kombinierte Messung für beide Parameter implementiert: Da auch diese in freier Atmung stattfindet, profitieren nicht nur die Differenzkarten von der Überlagerung der Bilder, sondern auch der Vergleich der ΔT1- und ΔT2*-Karten untereinander. Messungen mit einer konventionellen kartesischen Methode an COPD-Patienten unter Raumluft- und 100% Sauerstoffatmung ergaben bei Verwendung identischer Atemmasken ein deutlich geringeres ΔT1 als in gesunden Probanden. Dass T1 in der Lunge nicht nur von der Sauerstoffkonzentration sondern auch von der Gewebezusammensetzung und insbesondere auch dem Blutvolumenanteil abhängt, zeigte sich hierbei aber auch an den bei COPD im Mittel sehr viel kürzeren T1-Zeiten bei Raumluft. Die aufgrund emphysematischer Veränderung noch zusätzlich reduzierte Protonendichte im Parenchym kranker Lungen macht diese Messungen allerdings besonders schwierig. Die oben erwähnten Optimierungen der T1-Quantifizierung zielen daher auch darauf ab, das Signal aus der Lunge zu maximieren, um Patientenmessungen einfacher zu machen: Messungen in freier Atmung sind für Patienten nicht nur einfacher, sondern erlauben effektiv auch längere Messzeiten. Insbesondere wurde aber durch die Entwicklung einer radialen Methode die Echozeit zur Messung reduziert, um die kurze T2*-Zeit in der Lunge auszugleichen. Schließlich wurde durch Implementation einer 2D UTE Sequenz die Messung bei der kürzesten vom Scanner erlaubten Echozeit ermöglicht. Die Messungen bei ultrakurzen Echozeiten in Probanden zeigten allerdings deutlich kürzere T1-Zeiten als die zuvor gefundenen oder in der Literatur dokumentierten. In weiteren Experimenten wurde das sichtbare T1 zu mehreren Echozeiten mit Hilfe der zur kombinierten Quantifizierung entwickelten Methode bestimmt. Dabei ergab sich eine Zunahme des gemessenen T1 mit der Echozeit. Aus diesem Verhalten sowie den gefundenen kürzesten und längsten T1 lässt sich schließen, dass das intra- und extravaskuläre Lungenwasser, also Blut bzw. das umgebende Gewebe, mit unterschiedlichen T1- und T2*-Zeiten zum Signal und damit auch dem effektiven T1 beitragen. Dass das TE der Messung die Gewichtung dieser Kompartimente bestimmt, hat dabei mehrere Auswirkungen: Einerseits bedeutet dies, dass beim Vergleich von T1-Messungen in der Lunge stets auch das TE mitbetrachtet werden muss, bei dem diese durchgeführt wurden. Andererseits lässt sich die Möglichkeit, die Messung auf die unterschiedlichen Kompartimente abzustimmen, potentiell ausnutzen, um zusätzliche diagnostische Informationen zu gewinnen: Da T1 vom Blutvolumenanteil und der Gewebezusammensetzung abhängt, könnte dieser Effekt helfen, diese beiden Einflüsse zu differenzieren. Während die in dieser Arbeit beschriebenen Experimente die TE-Abhängigkeit des sichtbaren T1 in Probanden aufzeigen, liefern sie allerdings noch keine genaue Erklärung für die möglichen Ursprünge dieses Effekts. Um diese weiter zu untersuchen, könnten allerdings gezielte Phantom- und in vivo-Experimente Aufschluss geben: Ein Aufbau, der die Feldverzerrung durch luftgefüllte Alveolen in Lösungen mit entsprechenden verschiedenen Suszeptibilitäten nachbildet, reduziert den Unterschied zwischen den Kompartimenten auf T1 und χ. Eine in vivo-Messung mit möglichst großer Differenz zwischen Ex- und Inspiration hingegen könnte den Einfluss der Abstände der Kompartimente vom Gasraum aufzeigen, da die Alveolarwände in tiefer Inspiration am weitesten gedehnt und daher am dünnsten sind. N2 - In this work, methods for the local measurement of T1 and T2* maps optimized for the application in the human lungs are discussed: Quantification during free breathing was enabled by applying dc-gating, where a correction for the dc-signal acquired during T1-quantification using a inversion recovery was introduced. This is especially useful to achieve parameter maps in identical breathing states from multiple measurements using their dc-signals. Since T1 and T2* depend on the oxygen concentration through different mechanisms, this is especially interesting to produce ΔT1- and ΔT2*-difference maps at varying O2-concentrations in the breathing gas. Parameter quantification is primarily interesting for the monitoring of the courses of disease or therapy since T1 and T2* are absolute, comparable numbers. As T2* depends significantly on the respiratory state, ensuring identical states via gating is relevant there as well. To further improve the comparison of oxygen influence on T1 and T2* a method for the combined measurement of both parameters was implemented: Since this is also employs gating, not only the difference maps benefit from image coregistration, but the comparison of the ΔT1 and ΔT2* maps to each other as well. Measurements using the conventional cartesian method on COPD patients under room air and pure oxygen conditions resulted in much lower ΔT1 than in healthy volunteers when using identical oxygen masks. The much lower average T1 times at room air found there demonstrate that T1 in the lungs not only depends on the oxygen concentration but also on tissue composition and especially the blood volume fraction. Proton densities that were reduced even further due to emphysematous destruction made these measurements additionally difficult. Accordingly, the optimizations for T1 quantification mentioned above are intended to maximize signal from the lung parenchyma to improve patient measurements: Measurements during free breathing are not only easier for patients but effectively also allow for longer acquisition times. In particular the developement of a radial method provides a shorter echo time to help compensate for the short T2* in the lungs. Finally, the implementation of a 2D UTE sequence enables the measurement at the shortest echo time available on the scanner hardware. However, the measurements at ultra short echo times in volunteers showed significantly shorter T1 times than those found previously and those reported in the literature. In further experiments, the observable T1 was determined at multiple echo times using the method developed for simultaneous quantification. This revealed a gradual increase of the measured T1 with the echo time. From this behaviour as well as the shortest and longest times found, it can be concluded that the intra- and extravascular compartments of lung water, essentially blood and the surrounding tissue, contribute with different T1 and T2* times to the MR signal and thus also the effective T1. That the echo time of the measurement determines the weighting of these compartments has multiple consequences: Firstly, this means that when comparing T1 measurements in the lungs, the echo time that was used to acquire them also has to be considered. Secondly, the possiblity to focus the measurement on these different compartments might be used to gain additional diagnostic information: Since T1 depends on blood volume content and tissue composition, this effect might help to differentiate these two influences. While the experiments described in this work demonstrate the echo time dependence of the observed T1 in volunteers, they do not yet provide an explanation for the exact origins of this effect. To examine these further, appropriate phantom and in vivo experiments could be insightful: A phantom design that simulates the field distortion caused by air-filled alveoli in solutions with suitable susceptibilites would reduce the difference between the compartments to T1 and χ. A in vivo measurement with an especially large difference between ex- and inspiration could help to show the influence of the distance of the compartments from the gas space, since the alveolar walls are most dilated and thus thinnest during deep inspiration. KW - Kernspintomografie KW - Lunge KW - T2*-Relaxation KW - T1-Relaxtion KW - funktionelle Lungenbildgebung KW - MRT der Lunge KW - Spin-Gitter-Relaxation Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-139621 ER - TY - THES A1 - Treisch, Florian T1 - Die Entwicklung der Professionellen Unterrichtswahrnehmung im Lehr-Lern-Labor Seminar T1 - Assessing the professional vision of pre-service teachers in the Student-Lab N2 - Der Übergang vom der ersten Phase der Lehramtsausbildung ins Referendariat wird häufig mit dem Begriff „Praxisschock“ verbunden. Viele Studierende und Referendare fühlen sich unzureichend auf den Unterricht in der Schule vorbereitet. Sie fordern deshalb eine stärkere Verzahnung von Theorie und Praxis, also eine Anwendung der erlernten Theorien in „echten“ Praxisphasen auch schon in der ersten Phase der Lehramtsausbildung. Das Lehr-Lern-Labor Seminar der Universität Würzburg kann dazu beitragen, diese Verbindung von Theorie und Praxis herzustellen. Grundlegend sollen die Studierenden in diesem Seminar ihr fachliches, didaktisches und pädagogisches (Vor-)Wissen aufgreifen und in komplexitätsreduzierten Handlungsumgebungen anwenden. Dabei sollen sie im Rahmen des Lehr-Lern-Labor Seminars zunächst Experimentierstationen zu vorgegebenen Themengebieten aus dem bayerischen Lehrplan konzipieren, um anschließend mehrmals Schülerinnen und Schüler an diesen Stationen zu betreuen. Im Sinne einer iterativen Praxis werden die Betreuungen mehrmals von den Studierenden zusammen mit zwei Dozenten reflektiert. Letztlich wiederholen sich die Betreuungen, die Reflexionsphasen und mögliche Verbesserungen der Stationen viermal in einem zyklischen Prozess. Für die Verknüpfung von theoretischem Wissen in konkreten Handlungssituationen sind Wahrnehmungsprozesse von Bedeutung. Die sogenannte Professionelle Unterrichts-wahrnehmung beschreibt die Fähigkeit, relevante Unterrichtssituationen zu erkennen und theoriebezogen zu bewerten. Sie verknüpft das zugrunde liegende Wissen mit konkreten Handlungssituationen und dient somit als Bindeglied zwischen dem Wissen und dem Handeln, welches speziell in Reflexionsphasen gefördert werden kann. Durch die mehrmaligen Reflexionsprozesse der eigenen Betreuungen und die der Kommilitonen im Lehr-Lern-Labor Seminar könnte es eine vielversprechende Grundlage zur Förderung der Professionellen Unterrichtswahrnehmung darstellen. Die grundlegende Fragestellung der vorliegenden Arbeit ist es daher zu untersuchen, ob sich die Professionelle Unterrichtswahrnehmung im Rahmen des Lehr-Lern-Labor Seminars fördern lässt und inwieweit neu integrierte Videoanalysen der eigenen Betreuungen und die der Kommilitonen die Professionelle Unterrichtswahrnehmung der Studierenden zusätzlich fördern. Weiterhin interessiert, ob personenspezifische Merkmale einen zusätzlichen Einfluss auf die Entwicklung der Professionellen Unterrichtswahrnehmung ausüben. Ergänzend wird untersucht, ob zwischen dem Fachwissen, dem didaktischen Wissen und der Professionellen Unterrichtswahrnehmung Zusammenhänge bestehen. Dies könnte Aufschluss darauf geben, inwieweit Fachwissen und didaktisches Wissen die Entwicklung der Professionellen Unterrichtswahrnehmung im Seminar bedingen. Diese Arbeit leistet somit einen wichtigen Beitrag zur Untersuchung der Wirksamkeit eines Lehr-Lern-Labor Seminars, welches in die Ausbildung von Physiklehrkräften integriert wurde und zeigt auf, wie das Seminar bezüglich der Förderung der Professionellen Unterrichtswahrnehmung effektiver gestaltet werden kann. N2 - The transition from the first phase of the teacher education at the university to the two-year teacher training at school is often associated with the term “reality shock”. Many pre-service and in-service teachers feel inadequately prepared for teaching in schools. Therefore, there is an increasing call for a stronger connection of theory and practice. More precisely, pre-service teachers and educators demand an application of the theoretical knowledge in real practice situations already during education at the university. The Student-Lab seminar at the University of Würzburg can contribute to the connection of theory and practice. In this seminar, the participating pre-service teachers should use their content, didactical and pedagogical knowledge to create experimental stations for students on a given topic based on the Bavarian curriculum. Following, the pre-service teachers teach students on microteaching settings at the experimental stations. After every run, the pre-service teachers will reflect their teaching peer to peer and with the instructors. According to an iterative practice, there is an ongoing change of practice, reflection and improvement of the stations and the teaching. The connection of theory and practice is strongly related to professional vision. Professional vision describes the ability of a teacher to notice relevant teaching situations and to provide proper reasoning based on theoretical background. It links theoretical knowledge to specific teaching situations and serves as a connection between dispositions and performance, which can be learned during reflection. Due to the iterative reflections of their own teaching and the teaching of fellow students, the Student-Lab seminar could be a promising learning environment for the development of pre-service teachers’ professional vision. Therefore, the fundamental research questions are as follows: Is it possible to foster the pre-service teachers’ professional vision in the Student-Lab seminar? Furthermore, is there an additional effect due to newly integrated video analysis of their own and their fellows’ teaching in the Student-Lab? There is also an interest in the influence of individual characteristics on the development of professional vision. Another interest concerns the relation between the pre-service teachers’ content knowledge, didactical knowledge and their professional vision. This provides a hint to what extent the content knowledge and the didactical knowledge determine the development of professional vision. This work provides an important contribution to the investigation of the effectiveness of a Student-Lab integrated in the education of physics teachers. It gives indications for the organization and the learning contents of a Student-Lab seminar. KW - Lehramtsstudium KW - Lehr-Lern-Forschung KW - Schülerversuch KW - Lehr-Lern-Labor KW - Student-Lab KW - Professionelle Unterrichtswahrnehmung KW - professional vision KW - Videoanalyse KW - video analysis KW - Lehramt KW - Lehranalyse Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-164170 ER - TY - THES A1 - Tran-Gia, Johannes T1 - Model-Based Reconstruction Methods for MR Relaxometry T1 - Modellbasierte Rekonstruktionsmethoden für die MR-Relaxometrie N2 - In this work, a model-based acceleration of parameter mapping (MAP) for the determination of the tissue parameter T1 using magnetic resonance imaging (MRI) is introduced. The iterative reconstruction uses prior knowledge about the relaxation behavior of the longitudinal magnetization after a suitable magnetization preparation to generate a series of fully sampled k-spaces from a strongly undersampled acquisition. A Fourier transform results in a spatially resolved time course of the longitudinal relaxation process, or equivalently, a spatially resolved map of the longitudinal relaxation time T1. In its fastest implementation, the MAP algorithm enables the reconstruction of a T1 map from a radial gradient echo dataset acquired within only a few seconds after magnetization preparation, while the acquisition time of conventional T1 mapping techniques typically lies in the range of a few minutes. After validation of the MAP algorithm for two different types of magnetization preparation (saturation recovery & inversion recovery), the developed algorithm was applied in different areas of preclinical and clinical MRI and possible advantages and disadvantages were evaluated. N2 - Im Rahmen dieser Arbeit wurde ein modellbasiertes Verfahren namens MAP (engl. Model-based Acceleration of Parameter mapping) für die Bestimmung des T1-Gewebeparameters mittels Magnetresonanztomographie (MRT) entwickelt. Dieser iterative Algorithmus verwendet das Vorwissen über den nach einer Magnetisierungspräparation zu erwartenden Signalverlauf, um aus einer im Anschluss an eine initiale Präparation aufgenommene zeitliche Serie stark unterabgetasteter k-Räume eine Serie voll abgetasteter k-Räume zu generieren.Eine Fourier-Transformation dieser Serie in den Bildraum zeigt den örtlich aufgelösten zeitlichen Verlauf der longitudinalen Relaxation, was eine Kartierung des Gewebeparameters T1 ermöglicht. In seiner schnellsten Form ermöglicht dieses Verfahren die Rekonstruktion einer T1-Karte aus einem innerhalb weniger Sekunden nach einer passenden Magnetisierungspräparation aufgenommenen radialen Gradienten-Echo-Datensatz, während die Messdauer herkömmlich verwendeter T1-Bestimmungstechniken üblicherweise im Bereich von einigen Minuten liegt. Nach der Validierung des MAP-Algorithmus für zwei unterschiedliche Arten der Magnetisierungspräparation (Sättigungspräparation, Inversion) wurde die entwickelte Technik im Rahmen dieser Arbeit in verschiedenen Bereichen der präklinischen und klinischen MRT angewendet und mögliche Vor- und Nachteile untersucht. KW - Kernspintomographie KW - Radiologische Diagnostik KW - Bildgebendes Verfahren KW - Magnetic Resonance Relaxometry KW - Magnetresonanz-Relaxometrie KW - Model Based Reconstruction Algorithms in Magnetic Resonance Imaging KW - Modellbasierte-Rekonstruktionsalgorithmen in der Magnetresonanztomografie KW - Relaxation Parameter Mapping in Magnetic Resonance Imaging KW - Bestimmung des Relaxations-Parameters in der Magnetresonanztomografie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-109774 ER - TY - THES A1 - Trabel, Mirko T1 - Growth and Characterization of Epitaxial Manganese Silicide Thin Films T1 - Wachstum und Charakterisierung dünner epitaktischer MnSi Schichten N2 - This thesis describes the growth and characterization of epitaxial MnSi thin films on Si substrates. The interest in this material system stems from the rich magnetic phase diagram resulting from the noncentrosymmetric B20 crystal structure. Here neighboring spins prefer a tilted relative arrangement in contrast to ferro- and antiferromagnets, which leads to a helical ground state where crystal and spin helix chirality are linked [IEM+85]. This link makes the characterization and control of the crystal chirality the main goal of this thesis. After a brief description of the material properties and applied methods, the thesis itself is divided into four main parts. In the first part the advancement of the MBE growth process of MnSi on Si\((111)\) substrate as well as the fundamental structural characterization are described. Here the improvement of the substrate interface by an adjusted substrate preparation process is demonstrated, which is the basis for well ordered flat MnSi layers. On this foundation the influence of Mn/Si flux ratio and substrate temperature on the MnSi layer growth is investigated via XRD and clear boundaries to identify the optimal growth conditions are determined. The nonstoichiometric phases outside of this optimal growth window are identified as HMS and Mn\(_5\)Si\(_3\). Additionally, a regime at high substrate temperatures and low Mn flux is discovered, where MnSi islands are growing incorporated in a Si layer, which could be interesting for further investigations as a size confinement can change the magnetic phase diagram [DBS+18]. XRD measurements demonstrate the homogeneity of the grown MnSi layers over most of the 3 inch wafer diameter and a small \(\omega\)-FWHM of about 0.02° demonstrates the high quality of the layers. XRD and TEM measurements also show that relaxation of the layers happens via misfit dislocations at the interface to the substrate. The second part of the thesis is concerned with the crystal chirality. Here azimuthal \(\phi\)-scans of asymmetric XRD reflections reveal twin domains with a \(\pm\)30° rotation to the substrate. These twin domains seem to consist of left and right-handed MnSi, which are connected by a mirror operation at the \((\bar{1}10)\) plane. For some of the asymmetric XRD reflections this results in different intensities for the different twin domains, which reveals that one of the domains is rotated +30° and the other is rotated -30°. From XRD and TEM measurements an equal volume fraction of both domains is deduced. Different mechanisms to suppress these twin domains are investigated and successfully achieved with the growth on chiral Si surfaces, namely Si\((321)\) and Si\((531)\). Azimuthal \(\phi\)-scans of asymmetric XRD reflections demonstrate a suppression of up to 92%. The successful twin suppression is an important step in the use of MnSi for the proposed spintronics applications with skyrmions as information carriers, as discussed in the introduction. Because of this achievement, the third part of the thesis on the magnetic properties of the MnSi thin films is not only concerned with the principal behavior, but also with the difference between twinned and twin suppressed layers. Magnetometry measurements are used to demonstrate, that the MnSi layers behave principally as expected from the literature. The analysis of saturation and residual magnetization hints to the twin suppression on Si\((321)\) and Si\((531)\) substrates and further investigations with more samples can complete this picture. For comparable layers on Si\((111)\), Si\((321)\) and Si\((531)\) the Curie-Weiss temperature is identical within 1 K and the critical field within 0.1 T. Temperature dependent magnetoresistivity measurements also demonstrate the expected \(T^2\) behavior not only on Si\((111)\) but also on Si\((321)\) substrates. This demonstrates the successful growth of MnSi on Si\((321)\) and Si\((531)\) substrates. The latter measurements also reveal a residual resistivity of less then half for MnSi on Si\((321)\) in comparison to Si\((111)\). This can be explained with the reduced number of domain boundaries demonstrating the successful suppression of one of the twin domains. The homogeneity of the residual resistivity as well as the charge carrier density over a wide area of the Si\((111)\) wafer is also demonstrated with these measurements as well as Hall effect measurements. The fourth part shows the AMR and PHE of MnSi depending on the angle between in plane current and magnetic field direction with respect to the crystal direction. This was proposed as a tool to identify skyrmions [YKT+15]. The influence of the higher C\(_{3\mathrm{v}}\) symmetry of the twinned system instead of the C\(_3\) symmetry of a B20 single crystal is demonstrated. The difference could serve as a useful additional tool to prove the twin suppression on the chiral substrates. But this is only possible for rotations with specific symmetry surfaces and not for the studied unsymmetrical Si\((321)\) surface. Measurements for MnSi layers on Si\((111)\) above the critical magnetic field demonstrate the attenuation of AMR and PHE parameters for increasing resistivity, as expected from literature [WC67]. Even if a direct comparison to the parameters on Si\((321)\) is not possible, the higher values of the parameters on Si\((321)\) can be explained considering the reduced charge carrier scattering from domain boundaries. Below the critical magnetic field, which would be the region where a skyrmion lattice could be expected, magnetic hysteresis complicates the analysis. Only one phase transition at the critical magnetic field can be clearly observed, which leaves the existence of a skyrmion lattice in thin epitaxial MnSi layers open. The best method to solve this question seems to be a more direct approach in the form of Lorentz-TEM, which was also successfully used to visualize the skyrmion lattice for thin plates of bulk MnSi [TYY+12]. For the detection of in plane skyrmions, lamellas would have to be prepared for a side view, which seems in principle possible. The demonstrated successful twin suppression for MnSi on Si\((321)\) and Si\((531)\) substrates may also be applied to other material systems. Suppressing the twinning in FeGe on Si\((111)\) would lead to a single chirality skyrmion lattice near room temperature [HC12]. This could bring the application of skyrmions as information carriers in spintronics within reach. Glossary: MBE Molecular Beam Epitaxy XRD X-Ray Diffraction HMS Higher Manganese Silicide FWHM Full Width Half Maximum TEM Tunneling Electron Microscopy AMR Anisotropic MagnetoResistance PHE Planar Hall Effect Bibliography: [IEM+85] M. Ishida, Y. Endoh, S. Mitsuda, Y. Ishikawa, and M. Tanaka. Crystal Chirality and Helicity of the Helical Spin Density Wave in MnSi. II. Polarized Neutron Diffraction. Journal of the Physical Society of Japan, 54(8):2975, 1985. [DBS+18] B. Das, B. Balasubramanian, R. Skomski, P. Mukherjee, S. R. Valloppilly, G. C. Hadjipanayis, and D. J. Sellmyer. Effect of size confinement on skyrmionic properties of MnSi nanomagnets. Nanoscale, 10(20):9504, 2018. [YKT+15] T. Yokouchi, N. Kanazawa, A. Tsukazaki, Y. Kozuka, A. Kikkawa, Y. Taguchi, M. Kawasaki, M. Ichikawa, F. Kagawa, and Y. Tokura. Formation of In-plane Skyrmions in Epitaxial MnSi Thin Films as Revealed by Planar Hall Effect. Journal of the Physical Society of Japan, 84(10):104708, 2015. [WC67] R. H. Walden and R. F. Cotellessa. Magnetoresistance of Nickel-Copper Single-Crystal Thin Films. Journal of Applied Physics, 38(3):1335, 1967. [TYY+12] A. Tonomura, X. Yu, K. Yanagisawa, T. Matsuda, Y. Onose, N. Kanazawa, H. S. Park, and Y. Tokura. Real-Space Observation of Skyrmion Lattice in Helimagnet MnSi Thin Samples. Nano Letters, 12(3):1673, 2012. [HC12] S. X. Huang and C. L. Chien. Extended Skyrmion Phase in Epitaxial FeGe(111) Thin Films. Physical Review Letters, 108(26):267201, 2012. N2 - Diese Arbeit befasst sich mit dem Wachstum und der Charakterisierung dünner epitaktischer MnSi Schichten auf Si Substraten. Das Interesse an diesem Materialsystem liegt insbesondere im reichhaltigen magnetischen Phasendiagramm begründet, welches aus der nicht zentrosymmetrischen B20 Kristallstruktur des MnSi resultiert. Im Gegensatz zu Ferro- oder Antiferromagneten bevorzugen benachbarte Spins sich unter einem Winkel zueinander auszurichten, was zu einem helikalen Grundzustand führt in dem die Händigkeit von Kristallstruktur und Spin-Helix aneinander gekoppelt sind [IEM+85]. Diese Kopplung macht die Charakterisierung und Kontrolle der Händigkeit der Kristallstruktur zum Hauptziel dieser Arbeit. Nach einer kurzen Beschreibung der Materialeigenschaften und der angewendeten Methoden ist die Arbeit selbst in vier Hauptteile aufgeteilt. Im ersten Teil ist sowohl die Verbesserung des Molekularstrahlepitaxie-Wachstumsprozesses von MnSi auf Si\((111)\) Substrat, als auch die grundlegende strukturelle Charakterisierung beschrieben. Hierbei ist die Verbesserung der Substratgrenzfläche mit Hilfe eines angepassten Vorbereitungsprozesses erläutert, welche die Basis für glatte, geordnete dünne MnSi Schichten bildet. Auf dieser Basis ist der Einfluss des Mn/Si Fluss-Verhältnisses sowie der Substrattemperatur mittels Röntgenbeugung dargestellt und ein optimales Wachstumsfenster identifiziert. Die nicht stöchiometrischen Phasen außerhalb dieses Wachstumsfensters sind MnSi\(_{1.75-x}\) (HMS) sowie Mn\(_5\)Si\(_3\). Zusätzlich tritt bei hohen Substrattemperaturen und niedrigem Mn Fluss eine Phase auf, in der MnSi Inseln, eingebettet in eine Si Schicht, wachsen. Diese könnten von weiterführendem Interesse sein, da die Größenbeschränkung das magnetische Phasendiagramm beeinflussen kann [DBS+18]. Röntgenbeugungsmessungen zeigen die Homogenität der gewachsenen MnSi Schichten über einen Großteil des 3\ Zoll Wafer Durchmessers sowie die hohe Qualität mittels einer kleinen \(\omega\)-Halbwertsbreite von ungefähr 0.02°. Röntgenbeugungs- und Transmissionselektronenmikroskopiemessungen zeigen außerdem, dass die MnSi Dünnschichten mittels Fehlversetzungen an der Grenzfläche zwischen Dünnschicht und Substrat relaxieren. Der zweite Teil befasst sich mit der Händigkeit der Kristallstruktur. Azimutale \(\phi\)-Messungen asymmetrischer Röntgenbeugungsreflexe zeigen Kristallzwillingsdomänen welche \(\pm\)30° zum Substrat rotiert sind. Die Kristallzwillingsdomänen lassen sich vermutlich als rechts- und links-händiges MnSi identifizieren, welche durch eine Spiegelung an der \((\bar{1}10)\) Ebene verbunden sind. Anhand der unterschiedlichen Intensität mancher Reflexe für unterschiedliche Händigkeit wird außerdem gezeigt, dass eine der Domänen um +30° und die andere Domäne um -30° rotiert ist. Mithilfe der Röntgenbeugung und Transmissionselektronenmikroskopie wird außerdem der gleiche Volumenanteil der Kristallzwillinge demonstriert. Verschieden Mechanismen zur Unterdrückung dieser Kristallzwillingsdomänen werden untersucht und die erfolgreiche Unterdrückung gelang mit Hilfe des Wachstums auf chiralen Si Substraten, nämlich Si\((321)\) und Si\((531)\) Substraten. Hier ist mit azimutalen \(\phi\)-Messungen der asymmetrischen Röntgenbeugungsreflexen eine Unterdrückung von bis zu 92% demonstriert. Die erfolgreiche Unterdrückung der Kristallzwillingsdomänen ist ein wichtiger Schritt zur vorgeschlagenen Nutzung von MnSi in Spintronik-Anwendungen, wie in der Einleitung erläutert. Aufgrund dessen befasst sich der dritte Teil nicht nur mit den magnetischen Eigenschaften der dünnen MnSi Schichten, sondern auch damit, wie die Unterschiede für Schichten mit Kristallzwillingsdomänen und mit deren Unterdrückung sind. Im ersten Abschnitt ist anhand von Magnetometriemessungen gezeigt, dass sich die MnSi Dünnschichten prinzipiell so verhalten, wie es aus der Literatur zu erwarten ist. Das Verhalten von Sättigungs- und Restmagnetisierung deutet auf die Unterdrückung der Kristallzwillingsdomänen auf Si\((321)\) und Si\((531)\) Substraten hin, wobei das Gesamtbild mittels einer erweiterten Probenserie vervollständigt werden kann. Für vergleichbare MnSi Dünnschichten auf Si\((111)\), Si\((321)\) und Si\((531)\) ist die Curie-Weiss Temperatur innerhalb von 1 K und das kritische Magnetfeld innerhalb von 0.1 T identisch. Die Temperaturabhängigkeit des Magnetowiderstands zeigt das zu erwartende \(T^2\) Verhalten nicht nur auf Si\((111)\), sondern auch auf Si\((321)\). Dies zeigt das erfolgreiche Wachstum von MnSi auf Si\((321)\) und Si\((531)\). Die letzteren Messungen ergeben außerdem einen Restwiderstand von weniger als der Hälfte für MnSi auf Si\((321)\) im Vergleich zu Si\((111)\). Dies kann durch die geringere Anzahl an Domänengrenzen erklärt werden und zeigt die erfolgreiche Unterdrückung einer Kristallzwillingsdomäne. Mit Hilfe der Restwiderstände und Hall-Messungen ist die Homogenität des Restwiderstandes und der Ladungsträgerdichte über einen großen Bereich des Wafers gezeigt. Im vierten Teil werden der Anisotrope Magnetwiderstand und der Planare Hall Effekt für MnSi abhängig von den Winkeln von Stromrichtung und Magnetfeld im Bezug auf die Kristallrichtung untersucht. Dies wurde als Werkzeug zur Identifikation der Skyrmionenphase vorgeschlagen [YKT+15]. Der Einfluss der höheren C\(_{3\mathrm{v}}\) Symmetrie des Kristallzwillingssystems und nicht der C\(_3\) Symmetrie des B20 Einzelkristalls ist gezeigt Der Unterschied könnte ein nützliches zusätzliches Werkzeug für die Demonstration der Kristallzwillingsunterdrückung sein. Dies ist allerdings nur für die Rotation mit spezifischen symmetrischen Oberflächen möglich und nicht für die untersuchte unsymmetrische Si\((321)\) Oberfläche. Messungen von MnSi Dünnschichten auf Si\((111)\) oberhalb des kritischen Magnetfeldes zeigen die Abnahme der Anisotropie-Parameter für den Anisotropen Magnetwiderstand und den Planaren Hall-Effekt für steigenden Widerstand, wie aus der Literatur zu erwarten [WC67]. Auch wenn ein direkter Vergleich zu den Parametern für Dünnschichten auf Si\((321)\) nicht möglich ist, können die größeren Parameterwerte bei Si\((321)\) mit der reduzierten Streuung an Domänengrenzen erklärt werden. Die Analyse unterhalb des kritischen Magnetfeldes, der Bereich in dem eine mögliche Skyrmionenphase zu erwarten wäre, wird durch magnetische Hysterese verkompliziert. Nur ein Phasenübergang beim kritischen Magnetfeld kann deutlich gezeigt werden. Damit bleibt die Frage zur Existenz der Skyrmionen in den MnSi Dünnschichten weiter offen. Die beste Möglichkeit diese Frage zu klären wäre ein direkterer Ansatz in Form von Lorentz-Transmissionselektronenmikroskopie, welche schon erfolgreich genutzt wurde um das Skyrmionengitter in dünnen Platten aus Volumenkristall MnSi zu visualisieren [TYY+12]. Für die Detektion von Skyrmionen in der Schichtebene müssten Lamellen für eine Seitenansicht präpariert werden, was prinzipiell möglich erscheint. Die gezeigte erfolgreiche Unterdrückung von einem der Kristallzwillinge für MnSi Schichten auf Si\((321)\) und Si\((531)\) sollte außerdem auf andere Materialsysteme übertragbar sein. Die Kristallzwillingsbildung in FeGe auf Si\((111)\) zu unterdrücken würde zu einem Skyrmionengitter mit einer einzigen Händigkeit bei annähernd Raumtemperatur führen [HC12]. Dies könnte Skyrmionen als Informationsträger in der Spintronik in greifbare Nähe bringen. Bibliographie: [IEM+85] M. Ishida, Y. Endoh, S. Mitsuda, Y. Ishikawa, and M. Tanaka. Crystal Chirality and Helicity of the Helical Spin Density Wave in MnSi. II. Polarized Neutron Diffraction. Journal of the Physical Society of Japan, 54(8):2975, 1985. [DBS+18] B. Das, B. Balasubramanian, R. Skomski, P. Mukherjee, S. R. Valloppilly, G. C. Hadjipanayis, and D. J. Sellmyer. Effect of size confinement on skyrmionic properties of MnSi nanomagnets. Nanoscale, 10(20):9504, 2018. [YKT+15] T. Yokouchi, N. Kanazawa, A. Tsukazaki, Y. Kozuka, A. Kikkawa, Y. Taguchi, M. Kawasaki, M. Ichikawa, F. Kagawa, and Y. Tokura. Formation of In-plane Skyrmions in Epitaxial MnSi Thin Films as Revealed by Planar Hall Effect. Journal of the Physical Society of Japan, 84(10):104708, 2015. [WC67] R. H. Walden and R. F. Cotellessa. Magnetoresistance of Nickel-Copper Single-Crystal Thin Films. Journal of Applied Physics, 38(3):1335, 1967. [TYY+12] A. Tonomura, X. Yu, K. Yanagisawa, T. Matsuda, Y. Onose, N. Kanazawa, H. S. Park, and Y. Tokura. Real-Space Observation of Skyrmion Lattice in Helimagnet MnSi Thin Samples. Nano Letters, 12(3):1673, 2012. [HC12] S. X. Huang and C. L. Chien. Extended Skyrmion Phase in Epitaxial FeGe(111) Thin Films. Physical Review Letters, 108(26):267201, 2012. KW - Molekularstrahlepitaxie KW - Mangansilicide KW - Magnetische Eigenschaft KW - MnSi KW - Epitaxy KW - XRD KW - Twin Domains KW - Twin Suppression KW - Magnetometry KW - Magnetoresistance KW - Anisotropic Magnetoresistance KW - Röntgendiffraktometrie KW - Zwillingsbildung KW - Magnetismus KW - Magnetowiderstand Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-184720 ER - TY - THES A1 - Topczak, Anna Katharina T1 - Mechanismen des exzitonischen Transports und deren Dynamik in molekularen Dünnschichten für die organische Photovoltaik T1 - Mechanisms of the exciton transport and its dynamics in molecular thin films for organic photovoltaic applications N2 - Der Fokus dieser Arbeit liegt in der Untersuchung des exzitonischen Transports, sowie der Dynamik exzitonischer Zustände in organischen Halbleitern. Als fundamentale Fragestellung werden die inhärenten, materialspezifischen Parameter untersucht, welche Einfluss auf die Exzitonen-Diffusionslänge besitzen. Sowohl der Einfluss der strukturellen Ordnung als auch die fundamentalen exzitonischen Transporteigenschaften in molekularen Schichten werden anhand der archetypischen, morphologisch unterschiedlichen organischen Halbleiter Diindenoperylen (DIP), sowie dessen Derivaten, α-6T und C60 studiert. Die resultierende Filmbeschaffenheit wird mittels Röntgendiffraktometrie (XRD) und Rasterkraftmikroskopie (AFM) analysiert, welche Informationen über die Morphologie, die strukturelle Ordnung und die Mikrostruktur der jeweiligen molekularen Schichten auf verschiedenen Längenskalen liefern. Um Informationen über die Exzitonen-Diffusion und die damit einhergehende Exzitonen- Diffusionslänge LD zu erhalten, wurde die Methode des Photolumineszenz (PL)-Quenchings gewählt. Um umfassende Informationen zur Exzitonen-Bewegung in molekularen Dünnschichten zu erhalten, wurde mit Hilfe der Femtosekunden-Transienten-Absorptionsspektroskopie (TAS) und der zeitkorrelierten Einzelphotonenzählung (TCSPC) die Dynamik angeregter Energiezustände und deren jeweiliger Lebensdauer untersucht. Beide Messverfahren gewähren Einblicke in den zeitabhängigen Exzitonen-Transport und ermöglichen eine Bestimmung des Ursprungs möglicher Zerfallskanäle. Die zentralen Ergebnisse dieser Arbeit zeigen zum einen eine Korrelation zwischen LD und der strukturellen Ordnung der Schichtmorphologie, zum anderen weist die temperaturunabhängige Exzitonen-Bewegung in hochgeordneten polykristallinen DIP-Filmen auf die Möglichkeit der Existenz eines kohärenten Exzitonen-Transports bei tiefen Temperaturen unterhalb von 80 K hin. Zeitaufgelöste spektroskopische Untersuchungen lassen zudem auf ein breites Absorptionsband höherer angeregter Zustände schließen und weisen eine höhere Exzitonen- Zustandsdichte in polykristallinen DIP-Schichten im Vergleich zu ungeordneten Filmen auf. N2 - The objective of this work is the examination of the excitonic transport and its dynamics in organic semiconductors. A fundamental question dealt with in this thesis was related to inherent transport mechanisms, which govern the exciton diffusion length LD. To pursue this question, the excitonic transport in organic semiconductor thin films was examined in particular with regard to the influence of the structural coherence on LD as well as to the fundamental excitonic transport mechanisms. The resulting film structure of the samples is analyzed by means of X-ray diffraction (XRD) and atomic force microscopy (AFM), which yield to information on the morphology, the structural order and the microstructure of the molecular films on various length scales. PL-quenching investigations were performed to determine the exciton transport properties in different archetypical organic semiconductors represented by thin films of Diindenoperylene (DIP) and its derivatives, C60 and α-6T. To receive a comprehensive picture of exciton motion in molecular thin films, the exciton dynamics were investigated by femtosecond transient absorption spectroscopy (TAS) and time correlated single photon spectroscopy (TCSPC). Both measurement techniques gain insights into the time dependent exciton transport as well as help to assign the origin of the occurring decay-channels. The main results of this work reveal a correlation of LD with the structural order of the film morphology. In addition, a temperature independent excitonic motion in polycrystalline films of DIP at low temperatures < 80 K hints at the existence of a coherent exciton transport. Furthermore, time dependent spectroscopic investigations indicate a broad absorption band formed by higher excited states which exhibits a higher excitonic density of states in crystalline DIP-layers compared to films with a lower degree of structural order or amorphous texture. KW - Organische Solarzelle KW - Exzitonen Transport KW - Exzitonenbeweglichkeit KW - Exzitonen Diffusionslänge KW - Exzitonen Dynamik KW - Photolumineszenz Quenching KW - Diindenoperylen KW - C60 KW - Transiente Absorptionsspektroskopie KW - Exziton KW - Organische Halbleiter KW - Photolumineszenz Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-132280 ER - TY - THES A1 - Thierschmann, Holger T1 - Heat Conversion in Quantum Dot Systems T1 - Wärmeumwandlung in Quantenpunktsystemen N2 - This thesis treats the thermopower and other thermal effects in single quantum dots (QD) and quantum dot systems. It contributes new experimental results to the broad and active field of research on thermoelectrics in low dimensional systems. The thermopower experiments discussed in this work focus on QDs which exhibit a net spin and on tunnel-coupled double QDs (DQD). Furthermore, experiments are presented which address the realization of a QD device which extracts thermal energy from a heat reservoir and converts it into a directed charge current in a novel way. The samples used for these investigations have been fabricated from GaAs/AlGaAs heterostructures which contain a two dimensional electron gas. Using optical and electron beam lithography, the devices have been realized by means of the top-gate technology. All experiments have been performed at low temperature. In order to create a controllable temperature difference in the samples the current heating technique has been used. These experimental basics as well as fundamentals of electric and thermoelectric transport are introduced in Part I of this thesis. The experiments on the thermopower of a single QD are described in Part II. Essentially, they deal with the problem of how a single spin situated on a QD influences the thermoelectric properties of the system. In this context, the Kondo-effect plays a crucial role. Generally, the Kondo effect is the result of a many-body state which arises from an antiferromagnetic coupling of a magnetic impurity with the surrounding conduction electrons. Here, the magnetic impurity is represented by a QD which is occupied with an odd number of electrons so that it exhibits a net spin. For the first time the thermopower of a Kondo-QD has been studied systematically as a function of two parameters, namely the QD coupling energy and the sample temperature. Both parameters are crucial quantities for Kondo-physics to be observed. Based on these data, it is shown that the thermopower line shape as a function of QD energy is mainly determined by two competing contributions: On the one hand by the enhanced density of states around the Fermi level due to Kondo-correlations and on the other hand by thermopower contributions from the Coulomb resonances. Furthermore, the experiments confirm theoretical predictions which claim that the spectral DOS arising from Kondo-correlations shifts away from the Fermi level for those QD level configurations which are not electron-hole symmetric. Comparison with model calculations by T. Costi and V. Zlatic [Phys. Rev. B 81, 235127 (2010)] shows qualitative and partly even quantitative agreement. A finite thermovoltage at the center of the Kondo-region, which occurred in previous investigations, is also observed in the experiments presented here. It is not covered by the current theory of the Kondo effect. The dependence of this signal on temperature, coupling energy and magnetic field, which differ from non-Kondo regions, is analyzed. In order to clarify the physics behind this phenomenon further studies are desirable. Furthermore, it is shown by variation of the QD coupling energy over a wide range that Kondo-correlations can be detected in the thermopower even in the regime of very weak coupling. In contrast, no Kondo signatures are visible in the conductance in this energy range. It is found that in the limit of weak coupling the Kondo effect causes the thermopower to exhibit a diminished amplitude in close vicinity of a conductance resonance. Subsequent filling of spin-degenerate states then leads to a thermopower amplitude modulation (odd-even-effect). Although this effect had been observed in previous studies, no connection to Kondo physics had been established in order to explain the observations. Hence, the experiments on a single QD presented in this thesis provide unique insight into the complex interplay of different transport mechanisms in a spin-correlated QD. Moreover, the results confirm the potential of thermopower measurements as a highly sensitive tool to probe Kondo-correlations. In Part III thermal effects are investigated in systems which contain two coupled QDs. Such QD-systems are particularly interesting with respect to thermoelectric applications: Many proposals utilize the extremely sharp energy filtering properties of such coupled QDs and also different kinds of inter dot coupling to construct novel and highly efficient thermoelectric devices. In the present work, thermopower characterizations are performed on a tunnel-coupled DQD for the first time. The key result of these investigations is the thermopower stability diagram. Here it is found, that in such a system maximal thermopower is generated in the vicinity of the so-called triple points (TP) at which three charge states of the DQD are degenerate. Along the axis of total energy, which connects two adjacent TP, a typical thermopower line shape is observed. It is explained and modeled within an intuitive picture that assumes two transport channels across the DQD, representing the TP. For those regions which are far away from the TP, the thermopower turns out to be very sensitive to the relative configuration of the QD energies. The conductance and thermopower data are well reproduced within a model that assumes transport via molecular states. Integration of both models into one then allows model calculations for a complete stability cell in conductance and thermopower to be done. Furthermore, experiments on two capacitively coupled QDs are presented. In these studies the focus lies on testing the feasibility of such systems for the manipulation and generation of charge currents from thermal energy. In a series of experiments it is shown that such a system of QDs can be utilized to increase or decrease a current flowing between two electron reservoirs by varying the temperature in a third reservoir. This effect is based on the cross-correlation of occupation fluctuations of the individual QDs. These are positive for certain QD energy level configurations and negative for others, which increases or decreases the charge current in the experiments, respectively. In the stability diagram this is manifested in a characteristic clover leaf shaped structure of positive and negative current changes in vicinity of the TP. All main experimental results are reproduced qualitatively in simple model calculations. Due to the close analogy between electrical and thermal conductance of a QD, this effect of thermal switching can, in principle, also be used to built a thermal transistor. Finally, it is shown that a system consisting of two Coulomb-coupled QDs, which couple a hot electron reservoir electrostatically to two cold electron reservoirs, can be utilized as a novel device which extracts heat from its environment and converts it into a directed charge current. The idea of this heat-to-current converter (HCC) was first proposed by R. Sánchez and M. Büttiker [Phys. Rev. B 83, 085428 (2011)]. It is not only characterized by the novelty of its working principle but also by the fact, that it decouples the directions of charge current and energy flow. In the experiments presented here, such HCC-currents are identified unambiguously: For certain QD-level configurations an electric current between the two cold reservoirs is observed if the temperature in the third reservoir is increased. The direction of this current is shown to be independent of an external voltage. In contrast, the direction of the current exhibits a characteristic dependence on the tunneling coefficients of the QDs, as predicted by theory: By adjusting the thickness and the shape of the respective tunnel junctions, a charge current can be generated between two cold reservoirs, and it can even be inverted. The experimental observations are quantitatively reproduced by model calculations by R. Sánchez and B. Sothmann. Thus, the results represent direct evidence for the existence of HCC-currents. Due to the novelty of the working principle of the HCC and its relevance from a fundamental scientific point of view, the results presented here are an important step towards energy harvesting devices at the nano scale. N2 - Die vorliegende Arbeit befasst sich mit der Thermokraft und anderen thermischen Effekten in einzelnen Quantenpunkten (QP) und Quantenpunktsystemen. Sie liefert durch neue experimentelle Ergebnisse einen Beitrag zu dem breiten und besonders in jüngster Zeit stark beachteten Themenkomplex der Thermoelektrik in niedrigdimensionalen Systemen. Im Fokus stehen hier die Thermokraft von spin-besetzten QP und tunnelgekoppelten Doppelquantenpunkten (DQP) sowie die Realisierung von neuartigen W\ärmemaschinen mit Hilfe von QP-Systemen. Die für diese Untersuchungen verwendeten Proben wurden mit Hilfe der sogenannten split-gate Technologie lithographisch in einem zweidimensionalen Elektronengas innerhalb des Halbleiterschichtsystems GaAs/AlGaAs realisiert. Sämtliche Experimente wurden bei tiefen Systemtemperaturen durchgeführt. Zur kontrollierten Erzeugung einer Temperaturdifferenz wurde die sogenannte Stromheiztechnik verwendet. Diese experimentellen Grundlagen sowie allgemeine Hintergründe zur Physik von elektrischem und thermoelektrischem Transport werden im Gundlagenteil, Teil I, behandelt. Die Thermokraftexperimente an einzelnen QP sind in Teil II dieser Arbeit beschrieben. Sie befassen sich im Kern mit der Frage, auf welche Art einzelne Spins in einem QP die Thermokraft des Systems beeinflussen. In diesem Zusammenhang ist der Kondoeffekt von zentraler Bedeutung. Der Kondoeffekt resultiert allgemein aus einem Vielteilchenzustand, der durch die antiferromagnetische Kopplung einer magnetischen Verunreinigung mit Leitungselektronen der angrenzenden Reservoire hervorgerufen wird. Die magnetische Verunreinigung wird hier durch einen QP dargestellt, der Aufgrund einer ungeraden Besetzungszahl von Elektronenspins ein magnetisches Moment besitzt. In den präsentierten Experimenten wird erstmals systematisch der Verlauf der Thermokraft eines Kondo-QP in Abhängigkeit von den beiden Parametern Kopplungsenergie und Systemtemperatur untersucht. Diese beiden Parameter legen im Wesentlichen die Ausprägung des Kondozustandes fest. Auf der Basis dieser Daten wird gezeigt, dass der Verlauf der Thermokraft maßgeblich von dem konkurrierenden Einfluss zweier Beiträge bestimmt wird: Einerseits der Thermokraft resultierend aus einer erhöhten Zustandsdichte nahe der Fermienergie aufgrund von Kondokorrelationen und andererseits dem Beitrag der Coulombresonanzen. Des Weiteren belegen die Experimente die theoretisch vorhergesagte Verschiebung der spektralen Zustandsdichte auf dem QP weg von der Fermienergie, und zwar für solche Energieniveaukonfigurationen, welche nicht elektron-loch-symmetrisch sind. Vergleiche mit numerischen Berechnungen von T. Costi und V. Zlatic [Phys. Rev. B 81, 235127 (2010)] zeigen qualitative und teilweise sogar quantitative Übereinstimmung. Eine im Zentrum des Kondobereiches entstehende, elektronenartige Thermospannung, wie sie bereits in früheren Untersuchungen zum Kondoeffekt beobachtet wurde, kann auch in den Experimenten hier festgestellt werden. Sie wird durch die gegenwärtige Theorie zum Kondoeffekt nicht erklärt. Die experimentell gefundenen Abhängigkeiten dieses Signals von Temperatur, Kopplungsenergie und Magnetfeld unterscheiden sich von denen in Nicht-Kondobereichen und werden analysiert. Zur Klärung des physikalischen Hintergrundes dieses Phänomens sind weiterführende Experimente wünschenswert. Durch Variation der Kopplungsenergie über einen sehr weiten Bereich wird zudem gezeigt dass sich Kondokorrelationen noch bis hin zu sehr schwacher Kopplung in der Thermokraft nachweisen lassen. In diesen Energiebereichen weist der entsprechende Leitwert keinerlei Kondosignaturen mehr auf. Für die Thermospannung bewirkt der Kondoeffekt im Grenzfall schwacher Kopplung eine Reduktion der Amplitude nahe der Coulombresonanzen. Bei regelmäßiger Auffüllung von spin-entartetn QP-Orbitalen führt dies zu einer Amplitudenmodulation (Ungerade-Gerade-Effekt), wie sie bereits in früheren Arbeiten beobachtet, dort jedoch nicht mit Kondokorrelationen in Verbindung gebracht wurde. In ihrer Summe geben die Experimente auf einzigartige Weise neue Einblicke in das komplexe Zusammenwirken verschiedener Transportmechanismen in einem spinkorrelierten QP. Sie belegen das Potenzial von Thermokraftmessungen als hochsensitives Instrument zur Erforschung von Kondokorrelationen. In Teil III werden thermische Effekte in Systemen untersucht, welche zwei gekoppelte QP enthalten. Solche QP-Systeme sind insbesondere für thermoelektrische Anwendungen interessant: Zahlreiche Vorschläge nutzen die besonders präzisen Energiefiltereigenschaften von gekoppelten QP, aber auch unterschiedliche Arten der Kopplung zwischen den QP, zur Konzeption von neuen, hocheffizienten thermoelektrischen Bauteilen und neuartigen Wärme-Strom-Wandlern. In der vorliegenden Arbeit werden erstmalig Thermokraftmessungen an einem tunnelgekoppelten DQP in serieller Anordnung untersucht. Das zentrale Ergebnis dieser Experimente ist das Thermokraftstabilitätsdiagramm. Hier lässt sich beobachten, dass das System in der Region um die Tripelpunkte (TP), an denen drei Ladungszustände des DQP entartet sind, maximale Thermospannungen erzeugt. Entlang der Achse der Gesamtenergie wird ein charakteristischer Verlauf der Thermospannung beobachtet, der unter Annahme zweier Transportkanäle über den DQP, die TP, erklärt und modelliert werden kann. Abseits der TP zeigt sich, dass die Thermospannung höchst sensitiv auf die relative Anordnung der einzelnen QP-Energien reagiert. Eine Beschreibung des Ladungstransports durch molekülartige Zustände gibt hier die experimentellen Beobachtungen sehr gut wieder. Zusammenführung der Modelle für den Bereich nahe und fernab der TP erlaubt schliesslich die vollständige Modellierung des Stabilitätsdiagramms in Leitwert und Thermokraft. Des Weiteren werden Experimente an QP-Systemen mit zwei kapazitiv gekoppelten QP gezeigt. Hier steht die Nutzung solcher Systeme zur Manipulation oder Generation von elektrischen Strömen durch thermische Energie im Mittelpunkt. Es wird gezeigt, dass sich ein System kapazitiv gekoppelter QP eignet, den elektrischen Strom zwischen zwei Elektronenreservoiren durch Änderung der Temperatur in einem dritten Reservoir kontrolliert zu vergrössern oder zu vermindern. Der Effekt basiert dabei auf der Kreuzkorrelation der Elektronenbesetzungsfluktuation der beiden QP, welche in einigen QP-Energiekonstellationen positiv und in anderen Einstellungen negativ ist. So führt ersteres in den Experimenten bei Erhöhung der Temperatur zu einer Vergrösserung, letzters zu einer Verminderung des Stromflusses. Im Stabilitätsdiagramm erzeugt dieser Mechansimus ein charakteristisches Kleeblattmuster aus positiven und negativen Stromänderungen im Bereich der TP. Durch einfache Modellrechnungen können sämtliche experimentellen Beobachtungen qualitativ reproduziert werden. Aufgrund der Analogie zwischen Ladungstransport und Wärmetransport in einem QP ist auch eine Funktionsweise als rein thermischer Transistor denkbar. Schliesslich wird nachgewiesen, dass ein solches System aus zwei elektrostatisch wechselwirkenden QP und drei Elektronenreservoiren dazu genutzt werden kann, um auf neuartige Weise thermische Energie in einen gerichteten Ladungsstrom umzuwandeln. Das Konzept dieses Wärme-Strom-Wandlers (engl: Heat-to-Current Converter, HCC) folgt dabei einem Vorschlag von R. Sánchez und M. Büttiker [Phys. Rev. B 83, 085428 (2011)]: Es zeichnet sich nicht nur dadurch aus, dass der zugrundeliegende Mechanismus der Wärmewandlung neu ist, sondern auch dadurch, dass in diesem System die Richtungen von elektrischem Strom und Wärmestrom voneinander entkoppelt sind. In den hier präsentierten Experimenten können solche HCC-Ströme eindeutig nachgewiesen werden: Für bestimmte QP-Energiekonfigurationen wird ein elektrischer Strom zwischen den beiden kalten Reservoiren beobachtet, wenn die Temperatur in dem dritten Reservoir erhöht wird. Es wird gezeigt, dass die Richtung dieses Stroms unabhängig von einer extern angelegten Spannung ist. Die Stromrichtung läßt sich jedoch, wie durch die Theorie gefordert, durch Änderung der Tunnelkoeffizienten der QP beeinflussen. Sie kann durch Variation der Dicke und der Form der entsprechenden Tunnelbarrieren invertiert werden. Die experimentellen Beobachtungen werden durch Modellrechnungen von B. Sothmann und R. Sánchez quantitativ reproduziert. Sie sind somit ein direkter Beleg für die Existenz von HCC-Strömen. Aufgrund der Neuartigkeit des Konzepts und seiner Bedeutung für weitere thermoelektrische Anwendungen sind die hier präsentierten Ergebnisse ein wichtiger Schritt auf dem Weg hin zur Realisierung von Wärmemaschinen auf der Nanoskala. KW - Quantenpunkt KW - Thermoelektrizität KW - multi-terminal devices KW - coulomb coupled quantum dots KW - thermoelectrics KW - heat conversion KW - single electron transistor KW - Coulomb-Blockade KW - Kondo-Effekt KW - Energy Harvesting Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-133348 ER - TY - THES A1 - Thienel, Cornelius T1 - Exploring the transport properties of the three-dimensional topological insulator material HgTe T1 - Erkundung der Transporteigenschaften des dreidimensionalen Topologischen Isolators HgTe N2 - In der vorliegenden Dissertation werden die Transporteigenschaften von verspannten HgTe-Volumenkristallen untersucht. Verspanntes HgTe stellt einen dreidimensionalen topologischen Isolator dar und ist zur Erkundung von topologischen Oberflächenzuständen von speziellem Interesse, da es mit Hilfe von Molekularstrahlepitaxie in hoher Kristallqualität gewachsen werden kann. Die niedrige Defektdichte führt zu beachtlichen Ladungsträgerbeweglichkeiten, die deutlich über denen anderer topologischer Isolatoren liegen. Verspanntes HgTe hat jedoch eine kleine Energielücke von ca. 20 meV. Deshalb ist es für eine mögliche Verwendung des Materials ein wichtiger Aspekt, in welchem Parameterbereich Oberflächentransport stattfindet. Um dieser Frage nachzugehen, werden die HgTe-Proben bei tiefen Temperaturen (T < 100 mK) und unter dem Einfluss hoher Magnetfelder in verschiedenen Orientierungen untersucht. Der Einfluss von Gate-Elektroden ober- und unterhalb der Struktur sowie von Deckschichten, die die Oberflächen schützen, wird diskutiert. Basierend auf einer Analyse des Quanten-Hall-Effekts wird gezeigt, dass der Transport in diesem Material von topologischen Oberflächenzuständen dominiert ist. Die Abhängigkeit der topologischen Oberflächenzustände von der Gate-Spannung wird dargestellt. Durch diese Abhängigkeit ist es zum ersten Mal möglich, eine ungerade ganzzahlige Quanten-Hall-Plateau Sequenz nachzuweisen, die von den Oberflächen senkrecht zum Magnetfeld stammt. Des Weiteren wird im Rahmen dieser Arbeit in Proben hoher Oberflächenqualität zum ersten Mal für einen 3D TI der p-Typ QHE der Oberflächenzustände beobachtet. Aus der Gate-Abhängigkeit der Messungen wird geschlossen, dass das Abschirmverhalten in 3D TIs nicht trivial ist. Die Transportdaten werden mit Hilfe von intuitiven theoretischen Modellen auf qualitative Weise analysiert. N2 - In the present thesis the transport properties of strained bulk HgTe devices are investigated. Strained HgTe forms a 3D TI and is of special interest for studying topological surface states, since it can be grown by MBE in high crystal quality. The low defect density leads to considerable mobility values, well above the mobilities of other TI materials. However, strained HgTe has a small band gap of ca. 20 meV. With respect to possible applications the question is important, under which conditions the surface transport occurs. To answer this question, the HgTe devices are investigated at dilution refrigerator temperatures (T<100 mK) in high magnetic fields of different orientation. The influence of top and back gate electrodes as well as surface protecting layers is discussed. On the basis of an analysis of the quantum Hall behaviour it is shown that transport is dominated by the topological surface states in a surprisingly large parameter range. A dependence on the applied top gate voltage is presented for the topological surface states. It enables the first demonstration of an odd integer QHE sequence from the surfaces perpendicular to the magnetic field. Furthermore, the p-type QHE from the surface states is observed for the first time in any 3D TI. This is achieved in samples of high surface quality. It is concluded from the gate response that the screening behaviour in 3D TI devices is non-trivial. The transport data are qualitatively analysed by means of intuitive theoretical models. KW - Topologischer Isolator KW - Quecksilbertellurid KW - Elektronischer Transport KW - 3D topological insulator KW - Festkörperphysik KW - Hochmagnetfeld KW - Tieftemperatur KW - Quanten-Hall-Effekt Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-122031 ER - TY - THES A1 - Then, Patrick T1 - Waveguide-based single molecule detection in flow T1 - Wellenleiter-basierte Einzelmoleküldetektion in Strömungen N2 - In this work fluorescence-based single molecule detection at low concetration is investigated, with an emphasis on the usage of active transport and waveguides. Active transport allows to overcome the limits of diffusion-based systems in terms of the lowest detectable threshold of concentration. The effect of flow in single molecule experiments is investigated and a theoretical model is derived for laminar flow. Waveguides on the other hand promise compact detection schemes and show great potential for their possible integration into lab-on-a-chip applications. Their properties in single molecule experiments are analyzed with help of a method based on the reciprocity theorem of electromagnetic theory. N2 - Diese Arbeit untersucht fluoreszenzbasierte Einzelmoleküldetektion bei niedrigen Konzentrationen, mit einem Fokus auf den Einsatz von aktivem Transport und Wellenleitern. Aktiver Transport ermöglicht es, Limitierungen von diffusionsbasierten Systemen im Hinblick auf die niedrigste erreichbare Konzentration zu überwinden. Der Einfluss von Strömungen auf Einzelmolekülexperimente wird untersucht und ein theoretisches Modell für laminare Strömungen hergeleitet. Wellenleiter hingegen versprechen kompakte Detektorsysteme und zeigen beträchtliches Potential für eine mögliche Integration in lab-on-a-chip Anwendungen. Ihre Eigenschaften in Einzelmolekülexperimenten werden mithilfe einer auf dem Reziprozitätstheorem aus der elektromagnetischen Theorie basierenden Methode analysiert. KW - Optik KW - physics KW - optics KW - waveguides Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-140548 ER - TY - THES A1 - Tcakaev, Abdul-Vakhab T1 - Soft X-ray Spectroscopic Study of Electronic and Magnetic Properties of Magnetic Topological Insulators T1 - Spektroskopische Untersuchung der elektronischen und magnetischen Eigenschaften magnetischer topologischer Isolatoren mit weicher Röntgenstrahlung N2 - After the discovery of three-dimensional topological insulators (TIs), such as tetradymite chalcogenides Bi$_2$Se$_3$, Bi$_2$Te$_3$ and Sb$_2$Te$_3$ – a new class of quantum materials characterized by their unique surface electronic properties – the solid state community got focused on topological states that are driven by strong electronic correlations and magnetism. An important material class is the magnetic TI (MTI) exhibiting the quantum anomalous Hall (QAH) effect, i.e. a dissipationless quantized edge-state transport in the absence of external magnetic field, originating from the interplay between ferromagnetism and a topologically non-trivial band structure. The unprecedented opportunities offered by these new exotic materials open a new avenue for the development of low-dissipation electronics, spintronics, and quantum computation. However, the major concern with QAH effect is its extremely low onset temperature, limiting its practical application. To resolve this problem, a comprehensive understanding of the microscopic origin of the underlying ferromagnetism is necessary. V- and Cr-doped (Bi,Sb)$_2$Te$_3$ are the two prototypical systems that have been widely studied as realizations of the QAH state. Finding microscopic differences between the strongly correlated V and Cr impurities would help finding a relevant model of ferromagnetic coupling and eventually provide better control of the QAH effect in these systems. Therefore, this thesis first focuses on the V- and Cr-doped (Bi,Sb)$_2$Te$_3$ systems, to better understand these differences. Exploiting the unique capabilities of x-ray absorption spectroscopy and magnetic circular dichroism (XAS/XMCD), combined with advanced modeling based on multiplet ligand-field theory (MLFT), we provide a detailed microscopic insight into the local electronic and magnetic properties of these systems and determine microscopic parameters crucial for the comparison with theoretical models, which include the $d$-shell filling, spin and orbital magnetic moments. We find a strongly covalent ground state, dominated by the superposition of one and two Te-ligand-hole configurations, with a negligible contribution from a purely ionic 3+ configuration. Our findings indicate the importance of the Te $5p$ states for the ferromagnetism in (Bi, Sb)$_2$Te$_3$ and favor magnetic coupling mechanisms involving $pd$-exchange. Using state-of-the-art density functional theory (DFT) calculations in combination with XMCD and resonant photoelectron spectroscopy (resPES), we reveal the important role of the $3d$ impurity states in mediating magnetic exchange coupling. Our calculations illustrate that the kind and strength of the exchange coupling varies with the impurity $3d$-shell occupation. We find a weakening of ferromagnetic properties upon the increase of doping concentration, as well as with the substitution of Bi at the Sb site. Finally, we qualitatively describe the origin of the induced magnetic moments at the Te and Sb sites in the host lattice and discuss their role in mediating a robust ferromagnetism based on a $pd$-exchange interaction scenario. Our findings reveal important clues to designing higher $T_{\text{C}}$ MTIs. Rare-earth ions typically exhibit larger magnetic moments than transition-metal ions and thus promise the opening of a wider exchange gap in the Dirac surface states of TIs, which is favorable for the realization of the high-temperature QAH effect. Therefore, we have further focused on Eu-doped Bi$_2$Te$_3$ and scrutinized whether the conditions for formation of a substantial gap in this system are present by combining spectroscopic and bulk characterization methods with theoretical calculations. For all studied Eu doping concentrations, our atomic multiplet analysis of the $M_{4,5}$ x-ray absorption and magnetic circular dichroism spectra reveals a Eu$^{2+}$ valence, unlike most other rare earth elements, and confirms a large magnetic moment. At temperatures below 10 K, bulk magnetometry indicates the onset of antiferromagnetic ordering. This is in good agreement with DFT results, which predict AFM interactions between the Eu impurities due to the direct overlap of the impurity wave functions. Our results support the notion of antiferromagnetism coexisting with topological surface states in rare-earth doped Bi$_2$Te$_3$ and corroborate the potential of such doping to result in an antiferromagnetic TI with exotic quantum properties. The doping with impurities introduces disorder detrimental for the QAH effect, which may be avoided in stoichiometric, well-ordered magnetic compounds. In the last part of the thesis we have investigated the recently discovered intrinsic magnetic TI (IMTI) MnBi$_6$Te$_{10}$, where we have uncovered robust ferromagnetism with $T_{\text{C}} \approx 12$ K and connected its origin to the Mn/Bi intermixing. Our measurements reveal a magnetically intact surface with a large moment, and with FM properties similar to the bulk, which makes MnBi$_6$Te$_{10}$ a promising candidate for the QAH effect at elevated temperatures. Moreover, using an advanced ab initio MLFT approach we have determined the ground-state properties of Mn and revealed a predominant contribution of the $d^5$ configuration to the ground state, resulting in a $d$-shell electron occupation $n_d = 5.31$ and a large magnetic moment, in excellent agreement with our DFT calculations and the bulk magnetometry data. Our results together with first principle calculations based on the DFT-GGA$+U$, performed by our collaborators, suggest that carefully engineered intermixing plays a crucial role in achieving a robust long-range FM order and therefore could be the key for achieving enhanced QAH effect properties. We expect our findings to aid better understanding of MTIs, which is essential to help increasing the temperature of the QAH effect, thus facilitating the realization of low-power electronics in the future. N2 - Nach der Entdeckung von dreidimensionalen topologischen Isolatoren (TIs), einer neuen Klasse von Quantenmaterialien, die sich durch ihre einzigartigen elektronischen Oberflächeneigenschaften auszeichnen – und zu denen beispielsweise die Tetradymit-Di\-chal\-kogenide Bi2Se3, Bi2Te3 und Sb2Te3 gehören –, gerieten zunehmend topologische Zustände, deren Eigenschaften von starken elektronische Korrelationen und Magnetismus bestimmt werden, in den Fokus aktueller Festkörperforschung. Eine wichtige Materialklasse bilden die magnetischen TI (MTI), die einen quantenanomalen Hall-Effekt (QAH) aufweisen, d.h. eine dissipationsfreie, quantisierte Randzustandsleitfähigkeit in Abwesenheit eines externen Magnetfeldes, die aus dem Zusammenspiel von Ferromagnetismus und einer topologisch nicht-trivialen Bandstruktur resultiert. Die beispiellosen Möglichkeiten, die solche neuen, exotischen Materialien bieten, eröffnen einen neuen Weg für die Entwicklung von Elektronik mit geringer Verlustleistung, sowie von Spintronik und von Quanten\-com\-pu\-tern. Das Hauptproblem des QAH-Effekts ist jedoch die extrem niedrige Temperatur, bei der er auftritt, was seine praktische Anwendung einschränkt. Um dieses Problem zu lösen, ist ein umfassendes Verständnis des mikroskopischen Ursprungs des zugrunde liegenden Ferromagnetismus erforderlich. V- und Cr-dotiertes (Bi,Sb)2Te3 sind die beiden prototypischen Systeme, die als Realisierungen des QAH-Zustands umfassend untersucht wurden. Die Suche nach mikro\-skopischen Unterschieden zwischen den stark korrelierten V- und Cr-Dotieratomen würde helfen, ein relevantes Modell für die ferromagnetische Kopplung zu finden und schließlich eine bessere Kontrolle des QAH-Effekts in diesen Systemen zu ermöglichen. Daher konzentriert sich diese Arbeit zunächst auf die V- und Cr-dotierten (Bi,Sb)2Te3-Systeme, um diese Unterschiede besser zu verstehen. Unter Ausnutzung der einzigartigen Möglich\-keiten der Röntgenabsorptionsspektroskopie und des magnetischen Zirkulardichroismus (XAS/XMCD), kombiniert mit fortschrittlicher Modellierung auf der Grundlage der Multiplett-Liganden-Feld-Theorie (MLFT), geben wir einen detaillierten mi\-kro\-sko\-pi\-schen Einblick in die lokalen elektronischen und magnetischen Eigenschaften dieser Systeme und bestimmen mikroskopische Parameter, die für den Vergleich mit theoretischen Modellen entscheidend sind. Wir finden einen stark kovalenten Grundzustand, der von der Überlagerung von Ein- und Zwei-Te-Liganden-Loch-Konfigurationen dominiert wird, mit einem vernachlässigbaren Beitrag einer rein ionischen 3+ Konfiguration. Unsere Ergebnisse weisen auf die Bedeutung der Te 5p$−Zustände für den Ferromagnetismus in(Bi,Sb)\(2Te3 hin und deuten auf magnetische Kopplungsmechanismen mit pd-Austausch hin. Unter Verwendung modernster Dichtefunktionaltheorie (DFT)-Rechnungen in Kombination mit XMCD und resonanter Photoelektronenspektroskopie (resPES) demonstrieren wir die wichtige Rolle der 3d-Dotieratomzustände bei der Vermittlung der magnetischen Austauschkopplung. Unsere Berechnungen zeigen, dass die Art und Stärke der Austauschkopplung mit der 3d-Schalenbesetzung der Dotieratome variiert. Wir stellen eine Abschwächung der ferromagnetischen Eigenschaften bei Erhöhung der Dotierungskonzentration fest, ebenso wie bei Substitution von Bi an der Sb-Stelle. Schließlich beschreiben wir qualitativ den Ursprung der induzierten magnetischen Momente an den Te- und Sb-Stellen im Wirtsgitter und diskutieren ihre Rolle bei der Vermittlung eines robusten Ferromagnetismus auf der Grundlage des pd$−Austauschwechselwirkungsszenarios. Unsere Ergebnisse liefern wichtige Anhaltspunkte für die Entwicklung von MTIsmithöherem\(TC. Seltenerdionen weisen typischerweise größere magnetische Momente auf als Über\-gangsmetall-Ionen und legen daher die Öffnung einer größeren Austausch\-lücke in den Dirac-Ober\-flächenzuständen von TIs nahe, was für den Hochtemperatur-QAH-Effekt günstig ist. Daher haben wir uns weiter auf Eu-dotiertes Bi2Te3 konzentriert und untersucht, ob die Bedingungen für die Bildung einer substantiellen Lücke in diesem System gegeben sind, indem wir spektroskopische und Bulk-Charakterisierungsmethoden mit theoretischen Berechnungen kombiniert haben. Für alle untersuchten Eu\hyp{}Dotierungs\-kon\-zen\-trationen zeigt unsere atomare Multiplettanalyse der M4,5-Röntgenabsorptions- und der magnetischen Zirkulardichroismus-Spektren eine Eu2+-Valenz, im Gegensatz zu den meisten anderen Seltenen Erden, und bestätigt ein großes magnetisches Moment. Bei Temperaturen unter 10 K zeigt die Magnetometrie das Einsetzen einer antiferromagnetischen Ordnung an. Dies steht in guter Übereinstimmung mit DFT-Ergebnissen, die AFM-Wechselwirkungen zwischen den Eu-Dotieratomen aufgrund des direkten Überlapps der Wellenfunktionen der Dotieratome vorhersagen. Unsere Ergebnisse unterstützen die Annahme von Antiferromagnetismus, der mit topologischen Oberflächenzuständen in mit Seltenerdatomen dotiertem Bi2Te3 koexistiert, und bestätigen das Potenzial einer solchen Dotierung, einen antiferromagnetischen TI mit exotischen Quanteneigenschaften zu erzeugen. Dotierung führt zu einer für den QAH-Effekt nachteiligen Unordnung, die in stöchiometrischen, gut geordneten magnetischen Verbindungen vermieden werden kann. Im letzten Teil der Arbeit haben wir den kürzlich entdeckten, intrinsischen magnetischen TI (IMTI) MnBi6Te10 untersucht, in dem wir robusten Ferromagnetismus mit TC≈12 K beobachtet und seinen Ursprung mit Mn/Bi-Antilagendefekte (Substitution von Mn auf Bi-Plätzen und umgekehrt) in Verbindung gebracht haben. Unsere Messungen zeigen eine magnetisch intakte Oberfläche mit einem großen Moment und mit FM-Eigenschaften, die denen im Inneren des Materials ähnlich sind, was MnBi6Te10 zu einem vielversprechenden Kandidaten für den QAH-Effekt bei erhöhten Temperaturen macht. Darüber hinaus haben wir mit Hilfe eines fortgeschrittenen ab initio MLFT-Ansatzes die Grundzustandseigenschaften von Mn bestimmt und einen vorherrschenden Beitrag der d5-Konfiguration zum Grundzustand festgestellt, was zu einer d-Schalen-Elektronenbesetzung nd=5.31 und einem großen magnetischen Moment führt, in hervorragender Übereinstimmung mit unseren DFT-Berechnungen und den Daten der Magnetometrie. Unsere Ergebnisse, kombiniert mit den auf DFT-GGA+U basierenden First-Principle-Berechnungen, die von Kollegen durchgeführt wurden, deuten darauf hin, dass sorgfältig herbeigeführte Antilagendefekte eine entscheidende Rolle bei der Erzielung einer robusten langreichweitigen FM-Ordnung spielen und daher der Schlüssel zur Er\-zie\-lung verbesserter QAH\hyp{}Eigenschaften sein könnten. Wir erwarten, dass unsere Ergebnisse zu einem besseren Verständnis von MTIs beitragen werden, was wiederum die Erhöhung der Temperatur des QAH-Effekts und damit die Realisierung von Low-Power-Elektronik in der Zukunft erleichtern wird. KW - Topologischer Isolator KW - Röntgenspektroskopie KW - x-ray spectroscopy KW - topological insulators KW - XMCD Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-303786 ER - TY - THES A1 - Swirski, Thorben T1 - Studies on the Effect of Gas Contaminations in Micromegas Detectors and Production of Micromegas Detectors for the New Small Wheel of the ATLAS Detector T1 - Untersuchung des Einflusses von Gasverunreinigungen auf Micromegas Detektoren und Produktion von Micromegas Detektoren für das New Small Wheel des ATLAS Detektors N2 - This work consists of two parts. On the one hand, it describes simulation and measurement of the effect of contaminations of the detector gas on the performance of particle detectors, with special focus on Micromegas detectors. On the other hand, it includes the setup of a production site for the finalization of drift panels which are going to be used in the ATLAS NSW. The first part augments these two parts to give an introduction into the theoretical foundations of gaseous particle detectors. N2 - Diese Arbeit beinhaltet zwei Teile. Zum einen behandelt sie die Simulation und die Messung des Effekts von Verunreinigungen des Detektorgases auf Teilchen- detektoren, im speziellen vom Typ Micromegas. Zum anderen beinhaltet sie den Aufbau einer Produktionsstätte zur Vollendung von Driftpaneelen, die im ATLAS NSW Einsatz finden werden. Der erste Teil dieser Arbeit nimmt die Rolle eines Einführungsteiles ein, der die theoretischen Grundlagen von gasgefüllten Detekto- ren bespricht. KW - Gasionisationsdetektor KW - ATLAS KW - Micromegas KW - MPGD Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-246405 ER - TY - THES A1 - Swimm, Katrin T1 - Experimentelle und theoretische Untersuchungen zur gasdruckabhängigen Wärmeleitfähigkeit von porösen Materialien T1 - Experimental and theoretical investigations on the gas-pressure dependent thermal conductivity of porous materials N2 - Als Wärmedämmstoffe werden üblicherweise makroporöse Stoffsysteme wie Schäume, Pul-verschüttungen, Faservliese und – wolle eingesetzt. Zusätzlich finden mikro- und mesoporöse Dämmstoffe wie Aerogele Anwendung. Um effiziente Wärmedämmstoffe entwickeln zu können, muss der Gesamtwärmetransport in porösen Materialien verstanden werden. Die ein-zelnen Wärmetransport-Mechanismen Festkörperwärmeleitung, Gaswärmeleitung und Wärme-strahlung können zuverlässig analytisch beschrieben werden. Bei manchen porösen Materialien liefert jedoch auch eine Wechselwirkung zwischen den verschiedenen Wärmetransport-Mechanismen, d.h. die Kopplung von Festkörper- und Gaswärmeleitung, einen hohen Beitrag zur Gesamtwärmeleitfähigkeit. Wie hoch dieser Kopplungseffekt bei einer bestimmten Probe ausfällt, kann bisher schwer abgeschätzt werden. Um den Kopplungseffekt von Festkörper- und Gaswärmeleitung besser zu verstehen, sind sowohl experimentelle als auch theoretische Untersuchungen an verschiedenen porösen Stoffsystemen erforderlich. Zusätzlich kann ein zuverlässiges theoretisches Modell dazu beitragen, die mittlere Porengröße von porösen Mate-rialien zerstörungsfrei anhand von gasdruckabhängigen Wärmeleitfähigkeitsmessungen zu bestimmen. Als Modellsystem für die experimentellen Untersuchungen wurde der hochporöse Feststoff Aerogel verwendet, da seine strukturellen Eigenschaften wie Porengröße und Dichte während der Synthese gut eingestellt werden können. Es wurden Resorcin-Formaldehyd-Aerogele mit mittleren Porengrößen von etwa 600 nm, 1 µm und 8 µm sowie daraus mittels Pyrolyse abge-leitete Kohlenstoff-Aerogele synthetisiert und jeweils hinsichtlich ihrer Struktur und Wärme-leitfähigkeiten experimentell charakterisiert. Die Gesamtwärmeleitfähigkeiten dieser Aerogele wurden für verschiedene Gasatmosphären (Kohlenstoffdioxid, Argon, Stickstoff und Helium) in Abhängigkeit vom Gasdruck durch das Hitzdraht-Verfahren bestimmt. Hierfür wurde der Messbereich der Hitzdraht-Apparatur des ZAE Bayern mittels einer Druckzelle auf 10 MPa erweitert. Die Messergebnisse zeigen, dass bei allen Aerogel-Proben Festkörper- und Gaswär-meleitung einen deutlichen Kopplungsbeitrag liefern: Die gemessenen gasdruckabhängigen Wärmeleitfähigkeiten sind um Faktor 1,3 bis 3,3 höher als die entsprechenden reinen Gas-wärmeleitfähigkeiten. Die jeweilige Höhe hängt sowohl vom verwendeten Gas (Gaswärmeleitfähigkeit) als auch vom Aerogeltyp (Festkörperwärmeleitfähigkeit und Festkörperstruktur) ab. Ein stark vernetzter Festkörper verursacht beispielsweise einen niedrigeren Kopplungsbei-trag als ein weniger stark vernetzter Festkörper. Andererseits wurde die gasdruckabhängige Wärmeleitfähigkeit von Melaminharzschaum – einem flexiblen, offenporigen und hochporösen Material – in einer evakuierbaren Zwei-Plattenapparatur unter Stickstoff-Atmosphäre bestimmt. Das Material zeichnet sich dadurch aus, dass die Addition der Einzelwärmeleitfähigkeiten gut erfüllt ist, d.h. kein Kopplungsef-fekt auftritt. Allerdings konnte gezeigt werden, dass die gestauchte und damit unregelmäßige Struktur von Melaminharzschaum die Kopplung von Festkörper- und Gaswärmeleitung deut-lich begünstigt. Je stärker die Melaminharzschaumprobe komprimiert wird, umso stärker fällt der Kopplungseffekt aus. Bei einer Kompression um 84 % ist beispielsweise die gemessene gasdruckabhängige Wärmeleitfähigkeit bei 0,1 MPa um ca. 17 % gegenüber der effektiven Wärmeleitfähigkeit von freiem Stickstoff erhöht. Die experimentellen Untersuchungen wurden durch theoretische Betrachtungen ergänzt. Zum einen wurde die Kopplung von Festkörper- und Gaswärmeleitung anhand einer Serienschal-tung der thermischen Widerstände von Festkörper- und Gasphase dargestellt, um die Abhän-gigkeit von verschiedenen Parametern zu untersuchen. Dadurch konnte gezeigt werden, dass der Kopplungsterm stets von den Verhältnissen aus Festkörper- und Gaswärmeleitfähigkeit sowie aus den geometrischen Parametern beider Phasen abhängt. Des Weiteren wurden mit dem Computerprogramm HEAT2 Finite-Differenzen-Simulationen an Modellstrukturen durchgeführt, die für poröse Stoffsysteme, insbesondere Aerogel, charakteristisch sind (Stege, Hälse, Windungen und tote Enden). Die simulierten gasdruckabhängigen Wärmeleitfähigkeiten zeigen deutlich, dass die Festkörperstruktur mit der geringsten Vernetzung, d.h. das tote Ende, am meisten zur Kopplung von Festkörper- und Gaswärmeleitung beiträgt. Dies korre-liert mit den experimentellen Ergebnissen. Darüber hinaus kann man erkennen, dass die Ge-samtwärmeleitfähigkeit eines schlecht vernetzten porösen Systems, wo also ein hoher Kopp-lungseffekt (Serienschaltung) auftritt, niemals größer wird als die eines gut vernetzten Sys-tems mit gleicher Porosität, wo hauptsächlich paralleler Wärmetransport durch beide Phasen stattfindet. Schließlich wurden drei Modelle entwickelt bzw. modifiziert, um die gasdruckabhängige Wärmeleitfähigkeit von porösen Stoffsystemen theoretisch beschreiben zu können. Zunächst wurde ein für Kugelschüttungen entwickeltes Modell für Aerogel angepasst, d.h. Kopplung von Festkörper- und Gaswärmeleitung wurde nur in den Lücken zwischen zwei benachbarten Partikeln berücksichtigt. Ein Vergleich mit den Messkurven zeigt, dass der ermittelte Kopplungsterm zu gering ausfällt. Daher wurde ein bereits existierendes Aerogelmodell mit kubischer Einheitszelle, welches zusätzlich Kopplung zwischen den einzelnen Partikelsträngen beinhaltet, verbessert. Auch dieses Modell liefert keine zufriedenstellende Übereinstimmung mit den Messwerten, denn der Kopplungsbeitrag wird immer noch unterschätzt. Das liegt daran, dass die gewählte regelmäßige kubische Struktur für Aerogel zu ungenau ist. So geht bei der Berechnung des Kopplungsterms der bereits erwähnte hohe Beitrag durch tote Enden (und auch Windungen) verloren. Erfahrungsgemäß können jedoch alle für Aerogel erhaltenen gasdruckabhängigen Messkurven mit dem sogenannten Skalierungsmodell relativ gut beschrieben werden. Das entspricht dem Knudsen-Modell für reine Gaswärmeleitung, welches mit einem konstanten Faktor skaliert wird. Die Anwendung dieses einfachen Modells auf die Messdaten hat gezeigt, dass die Akkommodationskoeffizienten von Helium in Aerogel deut-lich höher sind als die Literaturwerte (ca. 0,3 auf Metalloberflächen): In den vermessenen RF- und Kohlenstoff-Aerogelen lassen sich Akkommodationskoeffizienten nahe 1 für Helium ab-leiten. Darüber hinaus ist das Skalierungsmodell gut geeignet, die mittleren Porengrößen poröser Materialien zuverlässig aus gasdruckabhängig gemessenen Wärmeleitfähigkeitskurven zu bestimmen. Dies stellt somit eine unkomplizierte und zerstörungsfreie Charakterisierungsmethode dar. N2 - Common thermal insulation materials are macro porous material systems such as foams, powders, fleeces and fibers. Additionally, micro and meso porous thermal insulations such as aerogels are employed. In order to further optimize thermal insulation materials, the total heat transfer in porous materials has to be quantified. The individual heat transfer mechanisms solid thermal conduction, gaseous thermal conduction and thermal radiation can be described reliably by analytic models. But for some porous materials an interaction of the different heat transfer mechanisms, i.e. coupling of solid and gaseous thermal conduction, occurs and can contribute significantly to the total effective thermal conductivity. So far, it is hard to predict the amount of this coupling contribution for a certain sample. For a better understanding of the coupling effect of solid and gaesous thermal conduction, both experimental and theoretical investigations on different porous material systems are required. Additionally, a reliable theoretical model can help to determine the mean pore size of porous materials in a nonde-structive way from gas-pressure dependent thermal conductivity measurements. Highly porous aerogel was used as model system for the experimental investigations, because its structural properties such as pore size and density can be adapted relatively well during synthesis. Resorcinol formaldehyde aerogels with mean pore sizes of about 600 nm, 1 µm and 8 µm as well as corresponding carbon aerogels obtained by pyrolysis were synthesized and experimentally characterized regarding their structural and thermal properties. Their total ef-fective thermal conductivities were determined by means of hot-wire measurements in different gas atmospheres (carbon dioxide, argon, nitrogen and helium) as a function of gas pressure. For this purpose, the measurement range of the hot-wire apparatus at ZAE Bayern was extended up to 10 MPa using a pressure chamber. The measurement results show that in all aerogel samples an obvious amount of coupling between solid and gaseous thermal conduction occurs: The gas-pressure dependent thermal contributions measured are by a factor of 1.3 to 3.3 higher than the corresponding pure gaseous thermal conductivities, depending on the pore gas (gaseous thermal conductivity) and the kind of aerogel (solid thermal conductivity and solid backbone structure). For example, a strongly connected solid phase causes a lower cou-pling contribution than a loosely connected one. On the other hand, the gas-pressure dependent thermal conductivity of melamine resin foam – a flexible and highly porous material with open pores – was determined with an evacuable guarded hot-plate apparatus in a nitrogen atmosphere. For this kind of material the simple ad-dition of the individual thermal conductivities is observed, i.e. no coupling occurs for standard conditions. However, if compressed, the structure of melamine resin foam becomes irregular and coupling of solid and gaseous thermal conduction occurs. The more the melamine resin foam sample is compressed, the stronger is the coupling effect. For example, the measured gas-pressure dependent thermal coductivity belonging to a compression by 84 % exceeds the effective thermal conductivity of free nitrogen by about 17 % at 0.1 MPa. The experimental investigations were supplemented by theoretical considerations. First of all, coupling of solid and gaseous thermal conduction was described by means of a series connec-tion of the thermal resistances of the solid and the gas phase, in order to examine the depend-ence on different parameters. This investigation shows, that the coupling term depends on the ratios of solid and gaseous thermal conductivity as well as of the geometrical parameters in both phases. Furthermore, with the computer program HEAT2, finite difference calculations were performed for model structures that are characteristic of porous material systems, espe-cially aerogel (struts, necks, torsions and dead ends). The simulated gas-pressure dependent thermal conductivity data show clearly, that the solid backbone structure with the weakest connectivity, i.e. the dead end, causes the highest amount of coupling between solid and gas-eous thermal conduction. This agrees with the experimental results. Moreover, it was found that the total effective thermal conductivity of a weakly connected porous system, where a high coupling effect (serial connection) occurs, never becomes larger than that of a well-connected system with the same porosity, where the heat transfer in both phases happens mostly in parallel. Finally, three models were developed or rather modified, in order to be able to describe the gas-pressure dependent thermal conductivity of porous material systems theoretically. At first, a model originally developed for packed beds of spherical particles was adapted to aerogel, i.e. coupling of solid and gaseous thermal conduction was only taken into account for the gaps between two adjacent particles. Comparison with the experimental curves shows that the coupling term calculated is too low. Therefore, an already existing aerogel model with a cubic unit cell, which includes additional coupling between the individual particle strings, was improved. The agreement of this model with the measurement curves is also very poor, because the cou-pling contribution is still underrated. This is due to the chosen regular cubic structure being too imprecise for irregularly formed aerogel backbones. Thus, when calculating the coupling term, the above-mentioned high contribution due to dead ends (and also torsions) gets lost. Empiri-cally however, all gas-pressure dependent measurement curves received for aerogel, can be described relatively well by the so-called scaling model. This is Knudsen’s model for pure gaseous thermal conduction scaled with a constant factor. The application of this simple model to the experimental data shows that the accommodation coefficients of helium in aerogel are significantly higher than the literature values (around 0.3 on metal surfaces): Within the RF and carbon aerogels investigated accommodation coefficients close to 1 can be derived for helium. Moreover, the scaling model is suitable for a reliable determination of the mean pore sizes of porous materials from gas-pressure dependent thermal conductivity data. Therefore, a straightforward and nondestructive characterization method was found. KW - Wärmeleitfähigkeit KW - Gasdruck KW - Poröser Stoff KW - Kopplung von Festkörper- und Gaswärmeleitung KW - Porengröße KW - coupling of gaseous and solid thermal conduction KW - pore size KW - Aerogel KW - Hitzdrahtverfahren Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-153887 ER - TY - THES A1 - Suchomel, Holger Maximilian T1 - Entwicklung elektrooptischer Bauteile auf der Basis von Exziton-Polaritonen in Halbleiter-Mikroresonatoren T1 - Development of electro-optical devices based on exciton polaritons in semiconductor microresonators N2 - Exziton-Polaritonen (Polaritonen), hybride Quasiteilchen, die durch die starke Kopplung von Quantenfilm-Exzitonen mit Kavitätsphotonen entstehen, stellen auf Grund ihrer vielseitigen und kontrollierbaren Eigenschaften einen vielversprechenden Kandidaten für die Entwicklung einer neuen Generation von nichtlinearen und integrierten elektrooptischen Bauteilen dar. Die vorliegende Arbeit beschäftigt sich mit der Entwicklung und Untersuchung kompakter elektrooptischer Bauelemente auf der Basis von Exziton-Polaritonen in Halbleitermikrokavitäten. Als erstes wird die Implementierung einer elektrisch angeregten, oberflächenemittierenden Polariton-Laserdiode vorgestellt, die ohne ein externes Magnetfeld arbeiten kann. Dafür wird der Schichtaufbau, der Q-Faktor, das Dotierprofil und die RabiAufspaltung der Polariton-Laserdiode optimiert. Der Q-Faktor des finalen Aufbaus beläuft sich auf Q ~ 16.000, während die Rabi-Aufspaltung im Bereich von ~ 11,0 meV liegt. Darauf aufbauend werden Signaturen der Polariton-Kondensation unter elektrischer Anregung, wie ein nichtlinearer Anstieg der Intensität, die Reduktion der Linienbreite und eine fortgesetzte Verschiebung der Emission zu höheren Energien oberhalb der ersten Schwelle, demonstriert. Ferner werden die Kohärenzeigenschaften des Polariton-Kondensats mittels Interferenzspektroskopie untersucht. Basierend auf den optimierten Halbleiter-Mikroresonatoren wird eine Kontaktplattform für die elektrische Anregung ein- und zweidimensionaler Gitterstrukturen entwickelt. Dazu wird die Bandstrukturbildung eines Quadrat- und Graphen-Gitters unter elektrischer Anregung im linearen Regime untersucht und mit den Ergebnissen der optischen Charakterisierung verglichen. Die erhaltenen Dispersionen lassen sich durch das zugehörige Tight-Binding-Modell beschreiben. Ferner wird auch eine elektrisch induzierte Nichtlinearität in der Emission demonstriert. Die untersuchte Laser-Mode liegt auf der Höhe des unteren Flachbandes und an der Position der Γ-Punkte in der zweiten Brillouin-Zone. Die zugehörige Modenstruktur weist die erwartete Kagome-Symmetrie auf. Abschließend wird die Bandstrukturbildung eines SSH-Gitters mit eingebautem Defekt unter elektrischer Anregung untersucht und einige Eigenschaften des topologisch geschützten Defektzustandes gezeigt. Dazu gehört vor allem die Ausbildung der lokalisierten Defektmode in der Mitte der S-Bandlücke. Die erhaltenen Ergebnisse stellen einen wichtigen Schritt in der Realisierung eines elektrisch betriebenen topologischen Polariton-Lasers dar. Abschließend wird ein elektrooptisches Bauteil auf der Basis von Polaritonen in einem Mikrodrahtresonator vorgestellt, in dem sich die Propagation eines PolaritonKondensats mittels eines elektrostatischen Feldes kontrollieren lässt. Das Funktionsprinzip des Polariton-Schalters beruht auf der Kombination einer elektrostatischen Potentialsenke unterhalb des Kontaktes und der damit verbundenen erhöhten ExzitonIonisationsrate. Der Schaltvorgang wird sowohl qualitativ als auch quantitativ analysiert und die Erhaltenen Ergebnisse durch die Modellierung des Systems über die GrossPitaevskii-Gleichung beschrieben. Zusätzlich wird ein negativer differentieller Widerstand und ein bistabiles Verhalten in der Strom-Spannungs-Charakteristik in Abhängigkeit von der Ladungsträgerdichte im Kontaktbereich beobachtet. Dieses Verhalten wird auf gegenseitig konkurrierende Kondensats-Zustände innerhalb der Potentialsenke und deren Besetzung und damit direkt auf den räumlichen Freiheitsgrad der PolaritonZustände zurückgeführt. N2 - Exciton-polaritons (polaritons), hybrid quasi-particles formed by the strong coupling between quantum well excitons and microcavity photons, are promising candidates for the realization of a new generation of nonlinear and integrated electrooptical devices. Compared to photonic or electrical approaches distinguishing advantages of Polaritons are their versatile and tuneable properties that allow electrical excitation and easy manipulation, which is both advantageous for on-chip applications. The present thesis deals with the development, implementation, and improvement of compact electrooptical devices based on exciton-polaritons in semiconductor microcavities. At first the implementation of an electrically driven vertically emitting polariton laser diode, which operates without the need of an applied magnetic field, is presented. For this purpose, the layer structure, quality factor, doping profile and Rabi-splitting of the polariton laser diode is optimized. The final design consists of a high-quality factor Al0.20Ga0.80As/AlAs microcavity (Q ~ 16,000) and features a Rabi-splitting of ~ 11.0 meV. Signatures for polariton condensation under electrical excitation are shown in the processed device. It features a clear nonlinearity in its input-output characteristic, a well-pronounced drop in the emission linewidth and a persisting blueshift above the first threshold with increasing pump-power. On top of that, evidence of the systems coherence properties in the condensed phase is provided directly by utilizing interference spectroscopy. Based on the optimized microcavity structures a process for the electrical excitation of one- and two-dimensional potential landscapes is developed. At first, the linear band structures of polaritonic square as well as honeycomb lattices are studied under electrical injection and compared to the results acquired by optical excitation. The obtained dispersions are reproduced by a tight-binding model. Moreover, the capability of the device to facilitate an electrically induced nonlinear emission is demonstrated. The investigated laser mode at the high symmetry Γ points in the second Brillouin zone, is located at the low energy flatband, as verified by the kagome geometry of the measured mode structure. Subsequent, the results of a one-dimensional SSH chain are presented under electrical excitation. In addition, the properties of a built-in lattice defect, forming a topological protected state in the middle of the S band gap, are investigated, paving the way towards the realization of electrically driven topological polariton lasers. Finally, an electrooptical polariton switch is demonstrated as a prototype of a polaritonic field-effect transistor. Here, an optical generated polariton condensate propagating along a one-dimensional channel is controlled by an electrical gate. The operation of the device relies on the combination of an electrostatic potential trap underneath the contact, and the associated exciton ionization. The switching behaviour is analysed in a qualitative as well as in a quantitative manner and verified by modelling the experimental findings with the Gross-Pitaevskii equation. Furthermore, a pronounced negative differential resistance and a strong bistability is observed in the photocurrent response as a function of the carrier density. This is attributed to competing transitions of trapped condensate modes and thus directly to the spatial degree of freedom of the polariton states, which represents a completely new way to create bistability. KW - Drei-Fünf-Halbleiter KW - AlGaAs KW - Exziton-Polariton KW - Optischer Resonator KW - Quantenwell KW - Mikroresonator KW - Polariton Lasing Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-271630 ER - TY - THES A1 - Stühler, Rudolf Raul Albert T1 - Growth and Spectroscopy of the Two-dimensional Topological Insulator Bismuthene on SiC(0001) T1 - Wachstum und Spektroskopie des zweidimensionalen topologischen Isolators Bismuthen auf SiC(0001) N2 - A plethora of novel material concepts are currently being investigated in the condensed matter research community. Some of them hold promise to shape our everyday world in a way that silicon-based semiconductor materials and the related development of semiconductor devices have done in the past. In this regard, the last decades have witnessed an explosion of studies concerned with so called ‘’quantum materials’’ with emerging novel functionalities. These could eventually lead to new generations of electronic and/or spintronic devices. One particular material class, the so called topological materials, play a central role. As far as their technological applicability is concerned, however, they are still facing outstanding challenges to date. Predicted for the first time in 2005 and experimentally verified in 2007, two-dimensional topological insulators (2D TIs) (a.k.a. quantum spin Hall insulators) exhibit the outstanding property of hosting spin-polarized metallic states along the boundaries of the insulating 2D bulk material, which are protected from elastic single-particle backscattering and give rise to the quantum spin Hall effect (QSHE). Owing to these peculiar properties the QSHE holds promise for dissipationless charge and/or spin transport. However, also in today’s best 2D TIs the observation of the QSHE is still limited to cryogenic temperatures of maximum 100 K. Here, the discovery of bismuthene on SiC(0001) has marked a milestone towards a possible realization of the QSHE at or beyond room-temperature owing to the massively increased electronic bulk energy gap on the order of 1 eV. This thesis is devoted to and motivated by the goal of advancing its synthesis and to build a deeper understanding of its one-particle and two-particle electronic properties that goes beyond prior work. Regarding the aspect of material synthesis, an improved growth procedure for bismuthene is elaborated that increases the domain size of the material considerably (by a factor of ≈ 3.2 - 6.5 compared to prior work). The improved film quality is an important step towards any future device application of bismuthene, but also facilitates all further basic studies of this material. Moreover, the deposition of magnetic transition metals (Mn and Co) on bismuthene is investigated. Thereby, the formation of ordered magnetic Bi-Mn/Co alloys is realized, their structure is resolved with scanning tunneling microscopy (STM), and their pristine electronic properties are resolved with scanning tunneling spectroscopy (STS) and photoemission spectroscopy (PES). It is proposed that these ordered magnetic Bi-Mn/Co-alloys offer the potential to study the interplay between magnetism and topology in bismuthene in the future. In this thesis, a wide variety of spectroscopic techniques are employed that aim to build an understanding of the single-particle, as well as two-particle level of description of bismuthene's electronic structure. The techniques involve STS and angle-resolved PES (ARPES) on the one hand, but also optical spectroscopy and time-resolved ARPES (trARPES), on the other hand. Moreover, these experiments are accompanied by advanced numerical modelling in form of GW and Bethe-Salpeter equation calculations provided by our theoretical colleagues. Notably, by merging many experimental and theoretical techniques, this work sets a benchmark for electronic structure investigations of 2D materials in general. Based on the STS studies, electronic quasi-particle interferences in quasi-1D line defects in bismuthene that are reminiscent of Fabry-Pérot states are discovered. It is shown that they point to a hybridization of two pairs of helical boundary modes across the line defect, which is accompanied by a (partial) lifting of their topological protection against elastic single-particle backscattering. Optical spectroscopy is used to reveal bismuthene's two-particle elecronic structure. Despite its monolayer thickness, a strong optical (two-particle) response due to enhanced electron-hole Coulomb interactions is observed. The presented combined experimental and theoretical approach (including GW and Bethe-Salpeter equation calculations) allows to conclude that two prominent optical transitions can be associated with excitonic transitions derived from the Rashba-split valence bands of bismuthene. On a broader scope this discovery might promote further experiments to elucidate links of excitonic and topological physics. Finally, the excited conduction band states of bismuthene are mapped in energy and momentum space employing trARPES on bismuthene for the first time. The direct and indirect band gaps are succesfully extracted and the effect of excited charge carrier induced gap-renormalization is observed. In addition, an exceptionally fast excited charge carrier relaxation is identified which is explained by the presence of a quasi-metallic density of states from coupled topological boundary states of domain boundaries. N2 - Zahlreiche neuartige Materialkonzepte werden derzeit in der Festkörperforschung untersucht. Einige von ihnen haben das Potenzial, unsere Alltagswelt in einer Weise zu beeinflussen, wie es Halbleitermaterialien auf Siliziumbasis und die damit verbundene Entwicklung von Halbleiterbauelemente in der Vergangenheit getan haben. In diesem Zusammenhang gab es in den letzten Jahrzehnten eine regelrechte Flut von Untersuchungen zu sogenannten „Quantenmaterialien“ mit völlig neuen Funktionalitäten. Diese könnten in Zukunft schließlich zu einer neuen Generation von elektronischen und/oder spintronischen Bauelementen führen. Eine spezielle Materialklasse, die so genannten topologischen Materialien, spielen dabei eine wichtige Rolle. Hinsichtlich ihrer technologischen Anwendbarkeit stehen sie jedoch bis heute vor großen Herausforderungen. Zweidimensionale topologische Isolatoren (2D TIs) (auch bekannt als Quanten Spin Hall Isolatoren) wurden erstmals 2005 vorhergesagt und schließlich 2007 experimentell bestätigt. Diese Materialien haben die außergewöhnliche Eigenschaft, dass sie spinpolarisierte metallische Zustände entlang der Grenzen des isolierenden 2D-Volumenmaterials aufweisen, die vor elastischer Ein-Teilchen-Rückstreuung geschützt sind und damit den Quanten-Spin-Hall-Effekt (QSHE) begründen. Aufgrund dieser besonderen Eigenschaften verspricht der QSHE einen dissipationsfreien Ladungs- und/oder Spintransport. Allerdings ist die Beobachtung des QSHE auch in den gegenwärtig am besten entwickelten 2D-TIs immer noch auf kryogene Temperaturen von maximal 100 K beschränkt. In diesem Zusammenhang war die Entdeckung von Bismuthen (engl. bismuthene) auf SiC(0001) ein Meilenstein in Bezug auf eine mögliche Realisierung des QSHE bei oder oberhalb von Raumtemperatur aufgrund der massiv vergrößerten elektronischen Volumenenergielücke in der Größenordnung von 1 eV. Dieser Arbeit liegt das Ziel und die Motivation zugrunde, die Synthese von Bismuthen zu verbessern und darüber hinaus das derzeitige Verständnis der elektronischen Ein- und Zweiteilchen-Eigenschaften dieses Materials zu erweitern. Was den Aspekt der Materialsynthese betrifft, so wird ein verbessertes Wachstumsverfahren für Bismuthen erarbeitet, das die Domänengröße des Materials beträchtlich erhöht (um einen Faktor von ≈ 3.2 - 6.5 im Vergleich zu früheren Arbeiten). Die verbesserte Filmqualität stellt einen wichtigen Schritt in Hinblick auf zukünftige Anwendungen von Bismuthen dar, erleichtert darüber hinaus aber auch alle grundlegenden Untersuchungen mit diesem Material. Darüber hinaus wird die Deposition von magnetischen übergangsmetallen (Mn und Co) auf Bismuthen erforscht. So konnten geordnete magnetische Bi-Mn/Co-Legierungen hergestellt werden, deren Struktur mit Rastertunnelmikroskopie (STM) und deren elektronische Eigenschaften mit Rastertunnelspektroskopie (STS) und Photoemissionsspektroskopie (PES) aufgelöst wurden. Es wird nahegelegt, dass diese geordneten magnetischen Bi-Mn/Co-Legierungen das Potenzial bieten, die Wechselwirkung zwischen Magnetismus und Topologie in Bismuthen in Zukunft zu untersuchen. In dieser Dissertation werden eine Vielzahl von spektroskopischen Techniken eingesetzt, die darauf abzielen, die elektronische Struktur von Bismuthen auf der Ein-Teilchen- und Zwei-Teilchen-Ebene zu verstehen. Die Techniken umfassen einerseits STS und winkelaufgelöste PES (ARPES), andererseits aber auch optische Spektroskopie und zeitaufgelöste ARPES (trARPES). Darüber hinaus werden diese Experimente durch umfangreiche numerische Modellierungen in Form von GW-Rechnungen und Lösungen der Bethe-Salpeter-Gleichung unterstützt, die von unseren theoretischen Kollegen durchgeführt wurden. Durch die Verknüpfung zahlreicher experimenteller und theoretischer Methoden setzt diese Arbeit auch einen Maßstab für die Untersuchung der elektronischen Struktur von 2D-Materialien im Allgemeinen. Basierend auf den Untersuchungen mit STS werden elektronische Quasiteilchen Interferenzen in quasi-1D Liniendefekten in Bismuthen entdeckt, die an Fabry-Pérot Zustände erinnern. Dabei wird gezeigt, dass diese Interferenzen auf eine Hybridisierung zweier Paare helikaler Grenzmoden über den Liniendefekt hinweg hinweisen, was mit einer (teilweisen) Aufhebung ihres topologischen Schutzes gegen elastische Ein-Teilchen-Rückstreuung einhergeht. Mit Hilfe optischer Spektroskopie wird die elektronische Zwei-Teilchen-Struktur von Bismuthen untersucht. Dabei ist trotz der Einzelschichtdicke eine starke optische, d.h. Zwei-Teilchen-, Antwort aufgrund der starken Elektron-Loch Coulomb-Wechselwirkungen zu beobachten. Der kombinierte experimentelle und theoretische Zugang (einschließlich GW Rechnungen und Lösungen der Bethe-Salpeter-Gleichung) erlaubt den Nachweis, dass zwei markante optische Übergänge Exzitonenanregungen sind, die von Valenzbändern von Bismuthen stammen, welche durch die Rashba-Wechselwirkung getrennt sind. Im weiteren Kontext könnte diese Entdeckung Anlass zu künftigen Experimenten sein, um die Zusammenhänge zwischen exzitonischer und topologischer Physik zu untersuchen. Schließlich werden erstmals die angeregten Leitungsbandzustände von Bismuthen mit Hilfe von trARPES energie- und impulsaufgelöst gemessen. Dabei ist es gelungen, die direkte und indirekte Bandlücke zu ermitteln und zudem den Effekt einer Ladungsträger induzierten Bandlücken-Renormalisierung zu beobachten. Darüber hinaus wird eine außergewöhnlich schnelle Relaxation angeregter Ladungsträger nachgewiesen, die durch das Vorhandensein einer quasi-metallischen Zustandsdichte aufgrund gekoppelter topologischer Randmoden an Domänengrenzen erklärt wird. KW - Topologischer Isolator KW - Rastertunnelmikroskop KW - Zweidimensionales Material KW - Bismuthene KW - helical edge states KW - honeycomb lattice KW - quantum spin hall insulator KW - two-dimensional topological insulator KW - trARPES KW - exciton KW - magnetic KW - Photoelektronenspektroskopie KW - Siliziumcarbid Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-320084 ER - TY - THES A1 - Stäb, Daniel T1 - Erweiterung der Anatomischen Abdeckung in der MRT des Herzens T1 - Anatomic Coverage Extension in Cardiac MRI N2 - Die MRT hat sich in den letzten Jahren zu einem wichtigen Instrument in der Diagnostik von Herzerkrankungen entwickelt. Da sie ohne ionisierende Strahlung auskommt, stellt sie vor allem auch eine nichtinvasive Alternative zu den nuklearmedizinischen Verfahren und der Computertomographie dar. Im speziellen ermöglicht die kardiale MRT die ortsaufgelöste Darstellung des Herzens mit einer Vielzahl an Kontrasten. Neben der Morphologie können damit auch zahlreiche Funktionsparameter des Herzens, wie die Ejektionsfraktion des linken Ventrikels, oder die Viabilität und Perfusion des Herzmuskels untersucht werden. Atmung und Herzbewegung stellen allerdings große Anforderungen an die MR-Herzbildgebung. Die beiden Störfaktoren limitieren den Zeitraum, der zur Bildakquisition zur Verfügung steht und erzeugen so Konflikte zwischen räumlicher Auflösung, anatomischer Abdeckung, zeitlicher Auflösung und dem Signal-zu-Rausch-Verhältnis (SNR). Ferner ergibt sich für die meisten eingesetzten Verfahren eine erhöhte Komplexität. Die Bildgebungssequenzen müssen mittels EKG an den Herzrhythmus des Patienten angepasst und die Bildakquisitionen im Atemanhaltezustand durchgeführt werden. In manchen Fällen ist sogar eine Aufspaltung der Messung in mehrere Einzelakquisitionen nötig, was wiederum die Dauer der Untersuchungen verlängert und den Patientenkomfort reduziert. Mit technischen Entwicklungen im Bereich der Gradienten und der Empfangsspulen sowie durch den Einsatz dedizierter Bildgebungstechniken konnten in den letzten Jahren signifikante Verbesserungen erzielt und der Stellenwert der MR-Bildgebung in der Herzdiagnostik erhöht werden. Von großer Bedeutung sind dabei auch Beschleunigungsverfahren wie die Parallele Bildgebung, die eine deutliche Verkürzung der Datenakquisition ermöglichen und so den Einfluss von Atmung und Herzbewegung wirksam reduzieren. Die Beschleunigung wird dabei grundsätzlich durch eine unvollständige Datenakquisition bzw. Unterabtastung des k-Raums erzielt, welche im Zuge der Bildrekonstruktion durch Ausnutzen zusätzlich vorhandener Informationen kompensiert wird. Bei der Parallelen Bildgebung ersetzen beispielsweise mehrere um das Objekt herum angeordnete Empfangsspulen die zum Teil unvollständig durchgeführte Gradientenbasierte Ortskodierung. Die Beschleunigungsverfahren sind allerdings wegen der verringerten Datenaufnahme auch immer mit einer Reduktion des SNR verbunden. Eine alternative Strategie zur Beschleunigung der 2D-Bildgebung mit mehreren Schichten stellt die simultane Multischichtbildgebung mit Multi-Slice Controlled Aliasing In Parallel Imaging Results In Higher Acceleration(MS-CAIPIRINHA) dar. Anders als bei der konventionellen Parallelen Bildgebung wird die Beschleunigung hier nicht durch eine reduzierte Datenaufnahme erzielt. Vielmehr werden Multiband-RF-Pulse eingesetzt, um die Spins in mehreren Schichten gleichzeitig anzuregen. Durch Anwenden schichtspezifischer RF-Phasenzyklen wird die Phase der Spins individuell in jeder Schicht moduliert, wodurch sich eine gegenseitige Verschiebung der Schichten im FOV ergibt. Die Verschiebung erleichtert die Separation der gleichzeitig angeregten Schichten mit Verfahren der Parallelen Bildgebung. Sie erlaubt außerdem eine Minimierung der bei der Rekonstruktion entstehenden Rauschverstärkung. Die Multischichtbildgebungstechnik zeichnet sich gegenüber der konventionellen Parallelen Bildgebung durch ein wesentlich höheres SNR und durch eine Bildrekonstruktion mit geringeren Rekonstruktionsfehlern aus. In dieser Dissertation wurden verschiedene Strategien zur Anwendung von MS-CAIPIRINHA in der MRT des Herzens präsentiert sowie ihre Vorund Nachteile gegenübergestellt. Im Allgemeinen ermöglichen die vorgestellten Konzepte eine hinsichtlich des SNR sehr effiziente Erweiterung der anatomischen Abdeckung. Unter anderem wurde eine Möglichkeit vorgestellt, mit der es uneingeschränkt gelingt, MS-CAIPIRINHA in der Bildgebung mit bSSFP-Sequenzen anzuwenden. Die Steady-State-Sequenz wird aufgrund ihres hohen intrinsischen SNR und vorteilhaften Kontrastverhaltens sehr häufig in der MRT des Herzens bei 1,5T eingesetzt. Wie auch die simultane Multischichtbildgebung erfordert sie zum Halten der Magnetisierung im stationären Zustand die Applikation eines dedizierten RF-Phasenzyklus während der Datenakquisition. Der Phasenzyklus der Sequenz ist allerdings nicht ohne Weiteres mit den Phasenzyklen der Multischichttechnik kompatibel, so dass eine Verknüpfung der beiden Verfahren bisher nur durch Aufspalten der Bildakquisition in mehrere Teilmessungen gelang. Mit dem in Kapitel 5 vorgestellten Konzept ist diese zumeist impraktikable Segmentierung nicht mehr erforderlich. Generalisierte RF-Phasenzyklen, die sowohl die Anforderungen der Sequenz, als auch die der Multischichtbildgebung erfüllen, ermöglichen eine uneingeschränkte Anwendung der Multischichttechnik in der Bildgebung mit bSSFP oder vergleichbaren Steady-State-Sequenzen. Die Multischichttechnik ist damit auch bei Untersuchungen in Echtzeit oder mit Magnetisierungspräparation – Verfahren, die unter anderem in der MR-Herzdiagnostik Verwendung finden – einsetzbar. Anhand von Echtzeit-, Cine- und First-Pass-Herzperfusionsuntersuchungen am menschlichen Herzen konnte die Anwendbarkeit des Konzepts erfolgreich demonstriert werden. Durch die Akquisition zweier Schichten in der Zeit, die normalerweise zur Bildgebung einer einzelnen Schicht benötigt wird, gelang eine Verdoppelung der anatomischen Abdeckung bei unverändert hoher Bildqualität. Bei den Herzperfusionsuntersuchungen konnten je RR-Intervall sechs Schichten akquiriert werden. Bei Echtzeit- und Cine-Messungen erlaubt das Konzept eine signifikante Reduktion der Anzahl der Atemanhaltezustände und dementsprechend eine wirksame Verkürzung der Patientenuntersuchung und eine Verbesserung des Patientenkomforts. In Kapitel 6 wurde eine effiziente Strategie zur Anwendung der simultanen Multischichtbildgebung in der First-Pass-Herzperfusionsbildgebung bei 3T vorgestellt. Es wurde gezeigt, dass durch den Einsatz von MS-CAIPIRINHA mit Beschleunigungsfaktoren, die größer sind als die Anzahl der simultan angeregten Schichten, neben der anatomischen Abdeckung auch die räumliche Auflösung innerhalb der Bildgebungsschicht erhöht werden kann. Beide Verbesserungen sind für die MR-gestützte Diagnostik der Koronaren Herzerkrankung von Bedeutung. Während mit einer hohen räumlichen Auflösung subendokardiale und transmurale Infarktareale unterschieden werden können, erleichtert eine hohe anatomische Abdeckung die genaue Eingrenzung hypoperfundierter Bereiche. Das grundsätzliche Prinzip der vorgestellten Strategie besteht in der Kombination zweier unterschiedlicher Beschleunigungsansätze: Zur Verbesserung der anatomischen Abdeckung kommt die simultane Multischichtbildgebung zum Einsatz. Zusätzlich zur gleichzeitigen Anregung mehrerer Schichten wird der k-Raum regelmäßig unterabgetastet. Die dabei erzielte Beschleunigung wird zur Verbesserung der räumlichen Auflösung eingesetzt. Die Bildrekonstruktion erfolgt mit Verfahren der Parallelen Bildgebung. Der Vorteil des Konzepts liegt insbesondere im vollständigen Erhalt der Datenakquisitionszeit gegenüber einer unbeschleunigten Messung mit Standardabdeckung und -auflösung. Anders als bei konventionellen Beschleunigungsverfahren wirken sich lediglich die Verkleinerung der Voxelgröße sowie die Rauschverstärkung der Bildrekonstruktion SNR-reduzierend aus. Die Rauschverstärkung wird dabei, durch die gegenseitige Verschiebung der simultan angeregten Schichten im FOV, so gering wie möglich gehalten. Die Anwendbarkeit des Konzepts konnte anhand von Simulationen sowie Untersuchungen an Probanden und Herzinfarktpatienten erfolgreich demonstriert werden. Simultanes Anregen zweier Schichten und 2,5-faches Unterabtasten des k-Raums ermöglichte die Durchführung von Untersuchungen mit einer anatomischen Abdeckung von sechs bis acht Schichten je RR-Intervall und einer räumlichen Auflösung von 2,0×2,0×8,0mm3. Es konnte gezeigt werden, dass die angewandte GRAPPA-Rekonstruktion, trotz der effektiv fünffachen Beschleunigung, robust und im Wesentlichen mit geringer Rauschverstärkung durchführbar ist. Bildqualität und SNR waren für eine sektorweise Absolutquantifizierung der Myokardperfusion ausreichend, während die hohe räumliche Auflösung die Abgrenzung kleiner subendokardialer Perfusionsdefizite ermöglichte. Aufgrund seiner großen Flexibilität und recht einfachen Implementierbarkeit ist das Beschleunigungskonzept vielversprechend hinsichtlich einer Anwendung in der klinischen Routine. Die diesbezügliche Tauglichkeit ist allerdings in weiterführenden Patientenstudien noch zu evaluieren. Alternativ zu diesem Konzept wurde in Kapitel 7 noch eine weitere, ebenfalls auf MS-CAIPIRINHA basierende Strategie für die First-Pass-Herzperfusionsbildgebung bei 3T mit großer anatomischer Abdeckung und hoher räumlicher Auflösung vorgestellt. Wie zuvor bestand die Grundidee des Konzepts darin, MS-CAIPIRINHA mit Beschleunigungsfaktoren anzuwenden, welche größer sind als die Anzahl der simultan angeregten Schichten und die Vergrößerung der anatomischen Abdeckung durch simultanes Anregen mehrerer Schichten zu realisieren. Um allerdings die bei der Bildrekonstruktion und Schichtseparation entstehende Rauschverstärkung zu minimieren, wurde zur Verbesserung der räumlichen Auflösung innerhalb der Schicht das nichtlineare Beschleunigungsverfahren Compressed Sensing zum Einsatz gebracht. Die erst in den letzten Jahren entwickelte Technik ermöglicht die exakte Rekonstruktion zufällig unterabgetasteter Daten, sofern bekannt ist, dass sich das rekonstruierte Bild in eine wohldefinierte sparse Darstellung überführen lässt. Neben der Erreichbarkeit hoher Beschleunigungsfaktoren bietet Compressed Sensing den Vorteil einer Bildrekonstruktion ohne signifikante Rauscherhöhung. Zur Einbindung des Verfahrens in das Multischichtbildgebungskonzept erfolgt die für die Verbesserung der Auflösung nötige Unterabtastung des k-Raums, zufällig und inkohärent. Zur Bildrekonstruktion sind zwei Teilschritte erforderlich. Im ersten Teilschritt werden die durch die zufällige Unterabtastung entstandenen inkohärenten Artefakte mit Compressed Sensing entfernt, im zweiten die gleichzeitig angeregten Schichten mit Verfahren der Parallelen MRT separiert. Es konnte gezeigt werden, dass die Kombination aus Compressed Sensing und MS-CAIPIRINHA eine Reduktion der inhomogenen Rauschverstärkung ermöglicht und zur Durchführung von qualitativen First-Pass-Herzperfusionsuntersuchungen mit einer Abdeckung von sechs bis acht Schichten je RR-Intervall sowie einer räumlichen Auflösung von 2,0 × 2,0 × 8,0mm3 geeignet ist. Des Weiteren konnte gezeigt werden, dass das angewandte Multischicht-Bildgebungskonzept einer Anwendung des entsprechenden Compressed-Sensing-Konzepts ohne simultane Multischichtanregung überlegen ist. Es stellte sich allerdings auch heraus, dass die rekonstruierten Bilder mit systematischen Fehlern behaftet sind, zu welchen auch ein signifikanter rekonstruktionsbedingter Verlust an zeitlicher Auflösung zählt. Dieser kann zu einer Verzerrung quantitativ bestimmter Perfusionswerte führen und verhindert so robuste quantitative Messungen der Myokardperfusion. Es ist außerdem davon auszugehen, dass auch abrupte Signalveränderungen, die bei Arrhythmien oder Bewegung auftreten, nur sehr ungenau rekonstruiert werden können. Die Systematischen Rekonstruktionsfehler konnten anhand zweier Verfahren, einer Monte-Carlo-Simulation sowie einer Analyse der lokalen Punktantworten präzise Untersucht werden. Die beiden Analysemethoden ermöglichten einerseits die genaue Bestimmung systematischer und statistischer Abweichungen der Signalamplitude und andererseits die Quantifizierung rekonstruktionsbedingter zeitlicher und räumlicher Auflösungsverluste. Dabei konnte ein Mangel an Sparsität als grundlegende Ursache der Rekonstruktionsfehler ermittelt werden. Die bei der Analyse eingesetzten Verfahren erleichtern das Verständnis von Compressed Sensing und können beispielsweise bei der Entwicklung nichtlinearer Beschleunigungskonzepte zur Bildqualitätsanalyse eingesetzt werden. N2 - In the recent years Magnetic Resonance Imaging (MRI) has become a powerful clinical tool for the diagnosis of cardiovascular diseases. In fact, getting along without ionizing radiation, the technique represents a noninvasive alternative to computed tomography or nuclear medicine treatment. In cardiac MRI, the heart can be imaged with a large variety of contrasts, which helps assessing not only morphologic but also functional information like the ejection fraction of the left ventricle or the viability and perfusion of the myocardium. However, having to deal with a moving organ, cardiac MRI is very challenging. In particular, breathing and the motion of the heart restrict the time available for imaging and a trade-off has to be found between signal-to-noise ratio (SNR), spatial resolution, anatomic coverage and temporal resolution. In addition, the motion enforces complexity. In-vivo examinations have to be performed in breath hold and ECG triggering has to be applied in order to adopt the sequences to the cardiac cycle. In several cases, measurements have to be split into multiple acquisitions which significantly prolongs the examination and reduces the patient comfort. Nevertheless, recent advances in gradient and receiver coil design in addition to the development of dedicated sequences for imaging led to significant improvements and helped strengthening the role of MRI in the diagnosis of cardiovascular diseases. A major part of the improvements has been achieved by employing acceleration techniques like Parallel Imaging. By substantially shortening the data acquisition they allow reducing the impact of motion onto the examinations. The acceleration is basically achieved by undersampling k-space, i.e. performing the data acquisition incompletely. The lack of data is compensated by making use of additional information inherently available. In Parallel Imaging for example, multiple receiver coils positioned around the subject to be investigated are utilized to partially replace the spatial encoding conventionally performed by gradient switching. However, employing these acceleration strategies always comes along with a reduction of the SNR since the time utilized for data sampling is shortened. For accelerating 2D measurements of multiple slices, an alternative approach is given by the simultaneous multi-slice imaging technique Multi-Slice Controlled Aliasing In Parallel Imaging Results In Higher Acceleration (MS-CAIPIRINHA). Unlike conventional Parallel Imaging, which requires shortening of the data acquisition, the technique provides acceleration by exciting the spins in multiple slices at the same time using multi-band radio frequency (rf) pulses. The slices are provided with specific rf phase cycles that allow shifting the simultaneously excited slices with respect to each other in the FOV. The shift facilitates the separation of the slices using Parallel Imaging reconstruction techniques. Moreover, it allows minimizing the inhomogeneous noise amplification coming along with the reconstruction. With respect to conventional Parallel Imaging, MS-CAIPIRINHA benefits from considerably higher SNR and an image reconstruction with less reconstruction errors. In this thesis several strategies for employing the simultaneous multi-slice imaging technique in the field of cardiac MRI have been presented together with their advantages and disadvantages. In general, the individual concepts allow for increasing the anatomic coverage in a very SNR efficient manner. First of all, a concept was presented that allows applying MS-CAIPIRINHA to bSSFP sequences. Providing an advantageous image contrast and intrinsically high SNR, the steady-state sequence is often utilized for cardiac MR examinations at field strengths of 1,5T. Like the simultaneous multi-slice imaging technique, it requires the strict application of a dedicated rf phase cycle to keep the magnetization in steady state. However, this rf phase cycle is incompatible to the rf phase cycles usually employed in MS-CAIPIRINHA. Thus, the combination of the two methods is impaired unless the imaging procedure is split into several measurements. This rather impractical segmentation is not required utilizing the concept proposed in chapter 5. By employing generalized rf phase cycles that match the requirements of the simultaneous multi-slice imaging technique while simultaneously fulfilling the steady state condition of the sequence, MS-CAIPIRINHA can be employed unrestrictedly to bSSFP or similar steady state sequences. The simultaneous multi-slice imaging technique is thus also applicable to magnetization prepared and real-time imaging modalities. Both types of examinations are frequently utilized in cardiac MRI. The applicability of the concept was successfully demonstrated for real-time cine, segmented cine and myocardial first-pass perfusion imaging. By scanning two slices in the time conventionally required for the acquisition of one single slice, the anatomic coverage could be doubled while maintaining the image quality almost completely. The myocardial first-pass perfusion examinations for example could be performed with a coverage of six slices every RR-interval. In real-time and cine imaging, the concept allows significantly reducing the number of breath holds that have to be performed. Thus, the examination is considerably shortened and the patient comfort ameliorated. In chapter 6, an efficient strategy for applying MS-CAIPIRINHA to contrast enhanced myocardial first-pass perfusion imaging at 3T was presented. It could be shown that by employing the simultaneous multi-slice imaging technique with an acceleration factor higher than the number of simultaneously excited slices, not only the anatomic coverage but also the spatial resolution can be increased. Both improvements are of importance for the MRI based diagnosis of coronary artery disease. While a high spatial resolution allows distinguishing between transmural and subendocardial hypoperfused regions, a large anatomic coverage facilitates their exact localization. The proposed technique is based on the combination of two different acceleration approaches: For increasing the anatomic coverage the simultaneous multi-slice imaging technique is employed. In addition to exciting multiple slices at once, k-space is regularly undersampled. This supplemental acceleration is utilized to increase the spatial resolution. Image calculation and slice separation is performed using conventional Parallel Imaging reconstruction techniques. In particular, the concept benefits from conserving the image acquisition time with respect to a non-accelerated examination with standard coverage and resolution. In contrast to conventional acceleration techniques, where significantly higher undersampling has to be performed, only the voxel size and the inhomogeneous noise amplification contribute to the SNR reduction. Moreover, the noise amplification is minimized by shifting the simultaneously excited slices with respect to each other in the FOV. The applicability of the concept was demonstrated on volunteers and patients. By exciting two slices at the same time and additionally undersampling k-space by a factor of 2.5, an anatomic coverage of six to eight slices every RR-interval and a spatial resolution of 2,0×2,0×8 0mm3 were achieved. The applied GRAPPA reconstruction algorithm was shown to allow for a robust image reconstruction with basically low noise amplification. The spatial resolution facilitated the differentiation between subendocardial and transmural hypoperfused areas and the image quality as well as the SNR were sufficiently high for a sectorwise absolute quantitative estimation of the myocardial blood flow. Regarding the high flexibility and simple applicability in addition to the robustness and speed of the image reconstruction, the concept is a promising candidate for clinical perfusion studies. However, further patient studies are required to prove the applicability of the concept in clinical routine. As an alternative to this concept, in chapter 7, a different acquisition strategy for myocardial first-pass perfusion imaging with extended coverage and high spatial resolution based on MS-CAIPIRINHA was presented. As before, the underlying idea was to apply the multi-slice imaging technique with acceleration factors higher than the number of slices excited at the same time and to achieve the anatomic coverage extension by means of simultaneous multislice excitation. Nevertheless, in order to minimize the inhomogeneous noise amplification coming along with the image reconstruction, the nonlinear acceleration method Compressed Sensing was employed for increasing the spatial resolution within the imaging plane. This recently developed acceleration technique allows exactly reconstructing MR images from randomly undersampled data as far as the reconstructed image can be sparsified by applying a well-defined transformation. The technique allows for high acceleration factors and benefits from an image reconstruction without significant noise amplification. In order to apply Compressed Sensing to the multi-slice imaging concept, the undersampling for resolution improvement is performed randomly and the image reconstruction is carried out in two separate steps. First, Compressed Sensing is applied in order to remove the incoherent artifacts introduced by random undersampling. Second, the slices are separated by applying conventional Parallel Imaging reconstruction techniques. It could be shown that combining MS-CAIPIRINHA with Compressed Sensing allows reducing the noise amplification and facilitates myocardial first-pass perfusion imaging with an anatomic coverage of six to eight slices every heartbeat and a spatial resolution of 2.0×2.0×8.0mm3. Moreover, it could be shown that the technique is superior to employing the Compressed Sensing concept without simultaneous multi-slice excitation. However, the concept also comes along with an impairment of image quality by systematic reconstruction errors. Amongst the latter for example there is a loss of temporal resolution, which might induce significant errors in a quantitative perfusion analysis. Robust quantitative measurements of the myocardial blood flow are thus not feasible so far. In presence of arrhythmia or motion, significant reconstruction errors, having a major impact onto the quality and the temporal fidelity of the measurement are expected. The systematic reconstruction errors could be precisely analyzed by employing a simple Monte Carlo simulation and a dedicated local point spread function analysis. The two specific tools were utilized to reveal the systematic and statistical deviations of the signal amplitude as well as the spatiotemporal resolution losses. A lack of sparsity could thereby be identified as the basic error cause. In general, the evaluation tools provide useful information for understanding the nonlinear character of Compressed Sensing and may be utilized for image quality analysis in the development of nonlinear reconstruction concepts. KW - Kernspintomographie KW - Herz KW - MRT KW - Herz KW - Parallele Bildgebung KW - CAIPIRINHA KW - Compressed Sensing KW - MRI KW - Cardiac KW - Parallel Imaging KW - Compressed Sensing KW - CAIPIRINHA KW - Biophysik Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-93405 ER - TY - THES A1 - Sturm, Volker Jörg Friedrich T1 - \(^{19}F\) Magnetresonanztomographie zur Bildgebung von Infektionen im Zeitverlauf T1 - \(^{19}F\) magnetic resonance imaging to monitor the timecourse of bacterial infections in vivo N2 - Im Rahmen dieser Arbeit sollten die Möglichkeiten der MR Tomographie erkundet werden bakterielle Infektionen im Zeitverlauf darzustellen. Genauer gesagt sollte das Potential der MR Tomographie anhand eines durch eine Infektion induzierten lokalisierten Abszesses unter Verwendung dreier unterschiedlicher MRT Methoden untersucht werden: Mittels nativem \(T_2\) Kontrast; der Verwendung von superparamagnetischen Eisenoxid Partieln (USPIO) als \(T_2^*\) Kontrastmittel; und dem Einsatz von Perfluorkarbonen (PFC) als \(^{19}F\) MRT Marker (siehe Kapitel 3). Wie erwartet führte die durch die Infektion hervorgerufene Entzündung zu veränderten \(T_2\)-Zeiten, welche auf \(T_2\)-gewichteten MR Bildern eine Lokalisierung des Abszessbereiches erlauben. Jedoch eigneten sich diese Daten aufgrund der graduellen Änderung der \(T_2\)-Zeiten nicht, um eine klare Grenze zwischen Abszess und umliegendem Gewebe zu ziehen. Superparamagnetische Eisenoxidpartikel andererseit haben als MRT Kontrastmittel bereits in den letzten Jahren ihre Fähigkeit unter Beweis gestellt Entzündungen [53, 58, 64] darzustellen. Die Anreicherung dieser Partikel am Rande des Abszesses [53], wie sie auch in unseren MR Daten zu beobachten war, erlaubte eine relativ scharfe Abgrenzung gegenüber dem umgebenden Gewebe in der chronischen Phase der Infektion (Tag 9 p.i.). Hingegen genügte die nur sehr spärlichen Anreicherung von USPIO Partikeln in der akuten Phase der Infektion (Tag 3 p.i.) nicht für eine entsprechende Abgrenzung [58]. Aufgrund der sehr geringen biologischen Häufigkeit und den sehr kurzen Relaxationszeiten von endogenem Fluor eignen sich Perfluorkarbone als Markersubstanz in der MR Tomographie von biologischen Systemen. Insbesondere da PFC Emulsionen durch phagozytierende Zellen aufgenommen werden und im Bereich von Entzündungen akkumulieren [30, 59]. In dieser Arbeit konnte anhand der erhaltenen MRT Daten eine Akkumulation von Perfluorkarbonen nicht nur in der chronischen Phase, sondern auch in der akuten Phase nachgewiesen werden. Diese Daten erlauben somit zu allen untersuchten Zeitpunkten eine Abgrenzung zwischen Infektion und umliegenden Gewebe. Aufgrund der besagten Vorteile wurden die Perfluorkarbone gewählt, um die Möglichkeiten der MR Tomographie zu testen, quantitative Informationen über die schwere der Infektion zu liefern. Als Referenz für die Bakterienbelastung wurden die Biolumineszenzbildgebung (BLI) [49, 50] und die Standardmethode zur Bestimmung der Bakterienbelastung cfu (koloniebildenden Einheiten) herangezogen. Eine Gegenüberstellung der zeitlichen Verläufe der durch die Biolumineszenzbildgebung und durch die cfu erhaltenen Daten liefert eine qualitative Übereinstimmung mit den durch die 19F MR Tomographie erhaltenen Daten. Dies trifft hierbei sowohl auf die über den gesamten Infektionsbereich hinweg summierten Signalamplituden, als auch auf das Volumen zu, in dem Fluor am Ort der Infektion akkumuliert wurde. Im Gegensatz zur Methode der cfu Bestimmung sind die MR Tomographie und die Biolumineszenzbildgebung nicht invasiv und erlauben die Verfolgung des Infektionsverlaufes an einem einzelnen Individuum. Hierzu benötigt, im Gegensatz zur MR Tomographie, die Methode der Biolumineszenzbildgebung jedoch einen speziellen Pathogenstamm. Darüber hinaus ist hervorzuheben, dass die MR Tomographie zudem die Möglichkeit bietet auch morphologische Informationen über den Infektionsbereich und seine Umgebung zu akquirieren. Gerade weil jede dieser Methoden die mit der Infektion einhergehenden Prozesse aus einer leicht anderen Blickrichtung betrachtet, erscheint es sinnvoll diese etablierte Untersuchungsplattform bestehend aus MRT, BLI und cfu über die in dieser Arbeit bearbeitete Fragestellung hinaus näher zu untersuchen. Insbesondere der Aspekt inwieweit die drei Methoden sich gegenseitig ergänzen, könnte einen tieferen Einblick in die Wechselwirkung zwischen Pathogen und Wirt erlauben. Auch wenn für die betrachtete Fragestellung bereits der hierdurchgeführte semiquanitative Ansatz zur Bestimmung der relativen Fluormengen am Ort der Infektion ausreichte, so ist doch im Allgemeinen wünschenswert probenbezogen die Sensitivität der Spule und damit die Güte der Spulenabstimmung zu bestimmen. Hierzu ist jedoch die Aufnahme von \(B_1\)-Karten unabdingbar und wird entsprechend im Kapitel 4 \(Bloch-Siegert B_1^+-Mapping\) näher addressiert. Der Schwerpunkt liegt hierbei, wie der Kapitelname bereits andeutet, auf der Bloch-Siegert Methode, die insbesondere in der präsentierten Implementierung in einer Turbo/ Multi Spin Echo Sequenz eine effiziente Nutzung der relativ langen \(T_\)2-Zeiten der Perfluorkarbone erlaubt. Da zudem die Bloch-Siegert-Methode eine rein phasenbasierte Methode ist, kann neben der aus den Daten erzeugten \(B_1\)-Karte zugleich ein unverfälschtes Magnitudenbild generiert werden, wodurch eine sehr effiziente Nutzung der vorhandenen Messzeit ermöglicht wird. Diese Eigenschaft ist insbesondere für \(^{19}F\) Bildgebung von besonderem Interesse, da hier für jede Messung, aufgrund der üblicherweise relativ geringen Konzentration an Fluoratomen, lange Messzeiten benötigt werden. Zusammenfassend konnte anhand des untersuchten Tiermodells sowohl die Fähigkeit der MR Tomographie nachgewiesen werden Infektionen im Zeitverlauf darzustellen, als auch die Fähigkeit der MR Tomographie quantitative Informationen über den Verlauf der Infektion zu liefern. Desweiteren konnte eine Möglichkeit aufgezeigt werden, welche das Potential hat in vertretbarem Zeitrahmen auch in vivo B1+-Karten auf dem Fluorkanal zu erstellen und so einen zentralen Unsicherheitsfaktor, für Relaxometry und absolute Quantifizierung von \(^{19}F\) Daten in vivo, zu beseitigen. N2 - The main focus of this work is to investigate the potential of magnetic resonance imaging (MRI) to monitor the timecourse of bacterial infections in vivo. More specifically, it focuses on the ability to localize and assess an infection-induced localized bulky abscess using three different MRI methods: the utilization of native \(T_2\) contrast; the usage of super paramagnetic iron oxide nanoparticles (USPIO) as MRI \(T_2^*\) contrast agents; and the application of perfluorcarbons (PFC) as \(^{19}F\) MRI marker (see chapter 3). Study results demonstrated that, as expected the altered \(T_2\) values present in the abscess area permit localization of the infection when using \(T_2\) weighted data. The precise boundary of the abscess, however, could not be determined due to the gradual change of the \(T_2\) values in the area of the infection. Conforming to other studies [53, 58], the MR-detected accumulation of USPIO particles along the abscess rim allowed definition of a fairly exact demarcation line between the abscess and surrounding tissue during the chronic phase of the infection (day 9 p.i.). During the acute phase of the infection (day 3 p.i.), however, the particle accumulation at the abscess rim was too sparse for precise boundary definition [58]. Because of their extremely low biological abundance and the very short relaxation times of endogenous fluorine, PFCs can be imaged background-free in a biological system. Moreover, as emulsified PFCs were taken up by phagocytosing cells and accumulated at the site of inflammation [30, 59], the acquired MRI data showed PFC accumulation during both the chronic and acute phases of infection. It was thus possible to differentiate between the abscess and surrounding tissue at each examined time point. Due to the described advantages, PFCs were chosen to evaluate with MRI the infection severity. As a bacterial burden reference, colony forming units (cfu) and bioluminescence imaging (BLI) [49, 50] were selected. Observation of BLI, cfu and \(^{19}F\) MRI data showed qualitative correlation during the investigated time course. This was true for the accumulated \(^{19}F\) MR signal in the area of infection and for the \(^{19}F\) MR signal volume. Additionally, unlike the cfu method MRI and BLI are non-invasive and thus data can be gathered at multiple time points. However, contrary to BLI, MRI does not require a special pathogen strain. Moreover, it can provide morphological data from an abscess and the surrounding tissue. Because the data delivered by each of these three methods (MRI, BLI and cfu), are based on alternative approaches, additional examinations of the established platform are suggested. For example, the extent to which the methods supplement each other may provide deeper insight into the interaction between pathogen and host. Even though the chosen semi quantitative approach was sufficient in the context of the evaluated issues to estimate the relative fluorine amount at the site of infection, it is in general desirable for each quantification to determine the sensitivity of the coil per sample. To address this issue the Bloch Siegert (BS) based \(B_1\) mapping method implemented in a turbo/ multi spin echo (TSE/MSE) sequence is presented in Chapter 4 Bloch-Siegert \(B_1^+\)-Mapping. Such a sequence allows effective use of the relatively long PFC \(T_2\) times and encodes BS information solely into the phase data. Thus, a \(B_1\) map can be created in addition to the unaltered TSE/MSE magnitude image. In the context of \(^{19}F\) imaging, this is of special interest due to the usually low amounts of fluorine resulting in long measurement times. In conclusion, it was shown that MRI not only enables visualization of the temporal behavior of infections on the investigated animal model, but it can also provide quantitative information about the progress of the infection. Additionally, a method potentially allowing in vivo B1+ mapping was introduced. This is an important step to improve the reliability of relaxometry and absolute quantification of in vivo \(^{19}F\) MRI. KW - Kernspintomografie KW - Bakterielle Infektion KW - 19F MR KW - Perfluorkarbon KW - Infektionsbildgebung KW - Bloch Siegert KW - B1 Mapping KW - Kontrastmittel Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-122851 ER - TY - THES A1 - Strunz, Jonas T1 - Quantum point contacts in HgTe quantum wells T1 - Quantenpunktkontakte in HgTe-Quantentrögen N2 - Quantenpunktkontakte (englisch: quantum point contacts, QPCs) sind eindimensionale Engstellen in einem ansonsten zweidimensionalen Elektronen- oder Lochsystem. Seit der erstmaligen Realisierung in GaAs-basierten zweidimensionalen Elektronengasen sind QPCs sukzessive zu einem Grundbestandteil mesoskopischer Physik geworden und erfahren in einer Vielzahl von Experimenten Anwendung. Jedoch ist es bis zur Anfertigung der vorliegenden Arbeit nicht gelungen, QPCs in der neuen Materialklasse der zweidimensionalen topologischen Isolatoren zu realisieren. In diesen Materialien tritt der sogenannte Quanten-Spin-Hall-Effekt (QSH-Effekt) auf, welcher sich durch die Ausbildung von leitfähigen, eindimensionalen sowie gleichermaßen spinpolarisierten Zuständen an der Bauteilkante auszeichnet, während die restlichen Bereiche der Probe isolierend sind. Ein in einem zweidimensionalen topologischen Isolator realisierter QPC kann demgemäß dafür benutzt werden, die sich stets an der Bauteilkante befindlichen QSH-Randkanäle einander räumlich anzunähern, was beispielsweise die Untersuchung potentieller Wechselwirkungseffekte zwischen ebenjenen Randkanälen ermöglicht. Die vorliegende Arbeit beschreibt die erstmalig erfolgreich durchgeführte Implementierung einer QPC-Technologie in einem QSH-System. Überdies werden die neuartigen Bauteile experimentell charakterisiert sowie analysiert. Nach einer in Kapitel 1 erfolgten Einleitung der Arbeit beschäftigt sich das nachfolgende Kapitel 2 zunächst mit der besonderen Bandstruktur von HgTe. In diesem Kontext wird die Ausbildung der QSH-Phase für HgTe-Quantentröge mit einer invertierten Bandstruktur erläutert, welche für deren Auftreten eine Mindesttrogdicke von d_QW > d_c = 6.3 nm aufweisen müssen. Im Anschluss wird das Konzept eines QPCs allgemein eingeführt sowie das zugehörige Transportverhalten analytisch beschrieben. Überdies werden die Einschränkungen und Randbedingungen diskutiert, welche bei der Realisierung eines QPCs in einem QSH-System Berücksichtigung finden müssen. Darauf folgt die Präsentation des eigens zur QPC-Herstellung entwickelten Lithographieprozesses, welcher auf einer mehrstufigen Anwendung eines für HgTe-Quantentrogstrukturen geeigneten nasschemischen Ätzverfahrens beruht. Die im Nachgang diskutierten Transportmessungen exemplarischer Proben zeigen die erwartete Leitwertquantisierung in Schritten von ΔG ≈ 2e^2/h im Bereich des Leitungsbandes -- sowohl für eine topologische als auch für eine triviale (d_QW < d_c) QPC-Probe. Mit dem Erreichen der Bandlücke saturiert der Leitwert für den topologischen QPC um G_QSH ≈ 2e^2/h, wohingegen ebenjener für den Fall des trivialen Bauteils auf G ≈ 0 abfällt. Darüber hinaus belegen durchgeführte Messungen des differentiellen Leitwertes einer invertierten QPC-Probe in Abhängigkeit einer Biasspannung die stabile Koexistenz von topologischen und trivialen Transportmoden. Gegenstand von Kapitel 3 ist die Beschreibung der Ausbildung eines QSH-Interferometers in QPCs mit geringer Weite, welche unter Verwendung von Quantentrögen mit einer Trogdicke von d_QW = 7 nm hergestellt werden. Die Diskussion von Bandstrukturrechnungen legt dar, dass die räumliche Ausdehnung der Randkanäle von der jeweiligen Position der Fermi-Energie im Bereich der Bandlücke abhängt. Hieraus resultiert eine Transportsituation, in welcher -- unter bestimmten Voraussetzungen -- Reservoir-Elektronen mit randomisiertem Spin an beide QSH-Randkanäle mit gleicher Wahrscheinlichkeit koppeln, was in der Ausbildung eines QSH-Rings resultiert. Diese Ringbildung wird im Rahmen eines durch Plausibilitätsüberprüfung getesteten Modells erklärt und spezifiziert. Danach erfolgt eine theoretische Einführung von drei relevanten Quantenphasen, deren Akkumulation in der Folge für mehrere geeignete QPC-Proben nachgewiesen wird. Es handelt sich hierbei um die Aharonov-Bohm-Phase, um die dynamische Aharonov-Casher-Phase sowie um eine Spin-Bahn-Berry-Phase mit einem Wert von π. Diese experimentellen Ergebnisse stehen darüber hinaus im Einklang mit analytischen Modellbetrachtungen. Das anschließende Kapitel 4 stellt den letzten Teil der Arbeit dar und beschäftigt sich mit der Beobachtung einer anomalen Leitwertsignatur, welche für QPC-Proben basierend auf einer Quantentrogdicke von d_QW = 10.5 nm auftritt. Diese Proben zeigen neben der durch die QSH-Phase bedingten Leitwertquantisierung von G_QSH ≈ 2e^2/h ein weiteres Leitwertplateau mit einem Wert von G ≈ e^2/h = 0.5 x G_QSH. Diese sogenannte 0.5-Anomalie ist nur für ein kleines Intervall von QPC-Weiten beobachtbar und wird mit zunehmender Bauteilweite abgeschwächt. Weiterführende Untersuchungen in Abhängigkeit der Temperatur sowie einer angelegten Biasspannung deuten darüber hinaus darauf hin, dass das Auftreten der 0.5-Anomalie mit einem modifizierten topologischen Zustand einhergeht. Überdies wird eine zusätzliche sowie vervollständigende Charakterisierung dieses Transportregimes durch die Realisierung eines neuartigen Bauteilkonzeptes möglich, welches einen QPC in eine standardisierte Hall-Bar-Geometrie integriert. Das Ergebnis der experimentellen Analyse einer solchen Probe verknüpft das Auftreten der 0.5-Anomalie mit der Rückstreuung eines QSH-Randkanals. Demgemäß wird aus Sicht des Einteilchenbildes geschlussfolgert, dass im Kontext der 0.5-Anomalie lediglich ein Randkanal transmittiert wird. Zudem werden zwei theoretische Modelle basierend auf Elektron-Elektron-Wechselwirkungen diskutiert, welche beide jeweils als ursächlicher Mechanismus für das Auftreten der 0.5-Anomalie in Frage kommen. Abschließend ist zu deduzieren, dass die Implementierung einer QPC-Technologie in einem QSH-System eine bedeutende Entwicklung im Bereich der Erforschung von zweidimensionalen topologischen Isolatoren darstellt, welche eine Vielzahl zukünftiger Experimente ermöglicht. So existieren beispielsweise theoretische Vorhersagen, dass QPCs in einem QSH-System die Detektion von Majorana- sowie Para-Fermionen ermöglichen. Überdies ist die nachgewiesene Ausbildung eines QSH-Interferometers in geeigneten QPC-Proben eine Beobachtung von großer Folgewirkung. So ermöglicht die beobachtete dynamische Aharonov-Casher-Phase im QSH-Regime die kontrollierbare Modulation des topologischen Leitwertes, was die konzeptionelle Grundlage eines topologischen Transistors darstellt. Eine weitere Anwendungsmöglichkeit wird durch die Widerstandsfähigkeit geometrischer Phasen gegenüber Dephasierung eröffnet, wodurch die nachgewiesene Spin-Bahn-Berry-Phase mit einem Wert von π im Kontext potentieller Quantencomputerkonzepte von Interesse ist. Darüber hinaus ist die Transmission von nur einem QSH-Randkanal im Zuge des Auftretens der 0.5-Anomalie äquivalent zu 100 % Spinpolarisierung, was einen Faktor essentieller Relevanz für die Realisierung spintronischer Anwendungen darstellt. Demgemäß beinhaltet die vorliegende Arbeit den experimentellen Nachweis von drei unterschiedlichen Effekten, von welchen jedem einzelnen eine fundamentale Rolle im Rahmen der Entwicklung neuer Generationen logischer Bauelemente zukommen kann -- ermöglicht durch die Realisierung von QPCs in topologischen HgTe-Quantentrögen. N2 - Quantum point contacts (QPCs) are one-dimensional constrictions in an otherwise extended two-dimensional electron or hole system. Since their first realization in GaAs based two-dimensional electron gases, QPCs have become basic building blocks of mesoscopic physics and are used in manifold experimental contexts. A so far unrealized goal however is the implementation of QPCs in the new material class of two-dimensional topological insulators, which host the emergence of the so-called quantum spin Hall (QSH) effect. The latter is characterized by the formation of conducting one-dimensional spin-polarized states at the device edges, while the bulk is insulating. Consequently, an implemented QPC technology can be utilized to bring the QSH edge channels in close spatial proximity, thus for example enabling the study of interaction effects between the edge states. The thesis at hand describes the technological realization as well as the subsequent experimental characterization and analysis of QPCs in a QSH system for the first time. After an introduction is given in Chapter 1, the subsequent Chapter 2 starts with discussing the peculiar band structure of HgTe. The emergence of the QSH phase for HgTe quantum wells with an inverted band structure is explained. For the band inversion to occur, the quantum wells have to exhibit a well thickness d_QW above a critical value (d_QW > d_c = 6.3 nm). Subsequently, the concept of QPCs is explicated and the corresponding transport behaviour is analytically described. Following the discussion of relevant constraints when realizing a QPC technology in a QSH system, a newly developed lithography process utilizing a multi-step wet etching technique for fabricating QPC devices based on HgTe quantum wells is presented. Transport measurements of exemplary devices show the expected conductance quantization in steps of ΔG ≈ 2e^2/h within the conduction band for a topological as well as for a trivial (d_QW < d_c) QPC. For the topological case, the residual conductance within the bulk band gap saturates at G_QSH ≈ 2e^2/h due to presence of the QSH state, while it drops to G ≈ 0 for the trivial device. Moreover, bias voltage dependent measurements of the differential conductance of an inverted sample provide explicit proof of the unperturbed coexistence of topological and trivial transport modes. In a next step, Chapter 3 describes the emergence of a QSH interferometer state in narrow QPC devices with a quantum well thickness of d_QW = 7 nm. Presented band structure calculations reveal that the spatial extension of the QSH edge states depends on the position of the Fermi energy within the bulk band gap. As a consequence, reservoir electrons with randomized spin couple to both edge channels with the same probability under certain conditions, thus causing the formation of a QSH ring. A straightforward model capturing and specifying the occurrence of such a QSH interferometer is provided as well as substantiated by two experimental plausibility checks. After relevant quantum phases are theoretically introduced, the discussion of the obtained data reveals the accumulation of an Aharonov-Bohm phase, of a dynamical Aharonov-Casher phase as well as of a spin-orbit Berry phase of π in appropriate QPC devices. These results are consistent with analytic model considerations. The last part of this thesis, Chapter 4, covers the observation of an unexpected conductance pattern for QPC samples fabricated from quantum wells with d_QW = 10.5 nm. In these devices, an anomalous plateau at G ≈ e^2/h = 0.5 x G_QSH emerges in addition to the QSH phase entailed residual conductance of G_QSH ≈ 2e^2/h. This so-called 0.5 anomaly occurs only for a specific interval of QPC width values, while it starts to get lost for too large sample widths. Furthermore, presented temperature and bias voltage dependent measurements insinuate that the emergence of the 0.5 anomaly is related to a gapped topological state. Additional characterization of this peculiar transport regime is provided by the realization of a novel device concept, which integrates a QPC within a standard Hall bar geometry. The results of the experimental analysis of such a sample link the occurrence of the 0.5 anomaly to a backscattered QSH channel. Thus, following a single particle perspective argumentation, it is reasoned that only one edge channel is transmitted in the context of the 0.5 anomaly. Two theoretic models possibly explaining the emergence of the 0.5 anomaly -- based on electron-electron interactions -- are discussed. To conclude, the implementation of a working QPC technology in a QSH system represents a paramount development in the context of researching two-dimensional topological insulators and enables a multitude of future experiments. QPC devices realized in a QSH system are for example envisaged to allow for the detection of Majorana fermions and parafermions. Furthermore, the reported formation of a QSH interferometer state in appropriate QPC devices is of high interest. The observed dynamical Aharonov-Casher phase in the QSH regime enables a controllable modulation of the topological conductance, thus providing the conceptual basis for a topological transistor. Moreover, due to the resilience of geometric phases against dephasing, the presence of a spin-orbit Berry phase of π represents a promising perspective with regard to possible quantum computation concepts. Besides that, the transmission of only one QSH edge channel due to the emergence of the 0.5 anomaly is equivalent to 100 % spin polarization, which is an essential ingredient for realizing spintronic applications. Hence, the thesis at hand covers the experimental detection of three effects of fundamental importance in the context of developing new generations of logic devices -- based on QPCs fabricated from topological HgTe quantum wells. KW - Topologischer Isolator KW - Quecksilbertellurid KW - Elektronentransport KW - HgTe KW - topological insulator KW - quantum point contact KW - quantum interference Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-274594 ER - TY - THES A1 - Strauß, Micha Johannes T1 - Molekularstrahlepitaxie von niederdimensionalen GaInAs(N) Systemen für AlGaAs Mikroresonatoren T1 - Molecular beam epitaxy of GaInAs(N) low dimensional Systems for AlGaAs micro resonators N2 - Die Erforschung von Quantenpunkten mit ihren quantisierten, atomähnlichen Zuständen, bietet eine Vielzahl von Möglichkeiten auf dem Weg zum Quantencomputer und für Anwendungen wie Einzelphotonenquellen und Quantenpunktlasern. Vorangegangene Studien haben grundlegend gezeigt, wie Quantenpunkte in Halbleiterresonatoren integriert und mit diesen gekoppelt werden können. Dazu war es zum einen notwendig, die Quantenpunkte und ihr epitaktisches Wachstum besser zu verstehen und zu optimieren. Zum anderen mussten die Bragg-Resonatoren optimiert werden, sodass Güten von bis zu 165.000 realisiert werden konnten. Eingehende Studien dieser Proben zeigten im Anschluss einen komplexeren Zusammenhang von Q-Faktor und Türmchendurchmesser. Man beobachtet eine quasi periodische Oszillation des Q-Faktors mit dem Pillar Durchmesser. Ein Faktor für diese Oszillation ist die Beschaffenheit der Seitenflanken des Resonatortürmchens, bedingt durch die unterschiedlichen Eigenschaften von AlAs und GaAs bei der Prozessierung der Türmchen. Darüber hinaus wurden in der Folge auf den Grundlagen dieser Strukturen sowohl optisch als auch elektrisch gepumpte Einzelphotonenquellen realisiert. Da in diesen Bauteilen auch die Lage des Quantenpunkts innerhalb des Resonatortürmchens einen erheblichen Einfluss auf die Effizienz der Kopplung zwischen Resonator und Quantenpunkt hat, war das weitere Ziel, die Quantenpunkte kontrolliert zu positionieren. Mit einer gezielten Positionierung sollte es möglich sein, ein Resonatortürmchen direkt über dem Quantenpunkt zu plazieren und den Quantenpunkt somit in das Maximum der optischen Mode zu legen. Besondere Herausforderung für die Aufgabenstellung war, Quantenpunkte in einem Abstand von mind. der Hälfte des angestrebten Türmchendurchmessers, d.h 0,5 μm bis 2 μm, zu positionieren. Die Positionierung musste so erfolgen, dass nach dem Wachstum eines AlAs/GaAs DBR Spiegel über den Quantenpunkten, Resonatortürmchen zielgenau auf die Quantenpunkte prozessiert werden können. Es wurden geeignete Prozesse zur Strukturierung eines Lochgitters in die epitaktisch gewaschene Probe mittels Elektronenstrahllithographie entwickelt. Für ein weiteres Wachstum mittels Molekularstrahlepitaxie, mussten die nasschemischen Reinigungsschritte sowie eine Reinigung mit aktivem Wasserstoff im Ultrahochvakuum optimiert werden, sodass die Probe möglichst defektfrei überwachsen werden konnte, die Struktur des Lochgitters aber nicht zerstört wurde. Es wurden erfolgreich InAs-Quantenpunkte auf die vorgegebene Struktur positioniert, erstmals in einem Abstand von mehreren Mikrometern zum nächsten Nachbarn. Eine besondere Herausforderung war die Vorbereitung für eine weitere Prozessierung der Proben nach Quantenpunktwachstum. Eine Analyse mittels prozessierten Goldkreuzen, dass 30 % der Quantenpunkte innerhalb von 50 nm und 60 % innerhalb von 100 nm prozessiert wurden. In der Folge wurde mit der hier erarbeiteten Methode Quantenpunkte erfolgreich in DBR-Resonatoren sowie photonische Kristalle eingebaut Die gute Abstimmbarkeit von Quantenpunkten und die bereits gezeigte Möglichkeit, diese in Halbleiterresonatoren einbinden zu können, machen sie auch interessant für die Anwendung im Telekommunikationsbereich. Um für Glasfasernetze Anwendung zu finden, muss jedoch die Wellenlänge auf den Bereich von 1300 nm oder 1550 nm übertragen werden. Vorangegangene Ergebnisse kamen allerdings nur knapp an die Wellenlänge von 1300nm. Eine fu ̈r andere Bauteile sowie für Laserdioden bereits häufig eingesetzte Methode, InAs-Quantenpunkte in den Bereich von Telekommunikationswellenla ̈ngen zu verschieben, ist die Verwendung von Stickstoff als weiteres Gruppe-V-Element. Bisherige Untersuchungen fokussierten sich auf Anwendungen in Laserdioden, mit hoher Quantenpunktdichte und Stickstoff sowohl in den Quantenpunkten als in den umgebenen Strukturen. Da InAsN-Quantenpunkte in ihren optischen Eigenschaften durch verschiedene Verlustmechanismen leiden, wurde das Modell eines Quantenpunktes in einem Wall (Dot-in-Well) unter der Verwendung von Stickstoff weiterentwickelt. Durch gezielte Separierung der Quantenpunkte von den stickstoffhaltigen Schichten, konnte e eine Emission von einzelnen, MBE-gewachsenen InAs Quantenpunkten von über 1300 nm gezeigt werden. Anstatt den Stickstoff direkt in die Quantenpunkte oder unmittelbar danach in die Deckschicht ein zu binden, wurde eine Pufferschicht ohne Stickstoff so angepasst, dass die Quantenpunkte gezielt mit Wellenlängen größer 1300 nm emittieren. So ist es nun möglich, die Emission von einzelnen InAs Quantenpunkten jenseits dieser Wellenlänge zu realisieren. Es ist nun daran, diese Quantenpunkte mit den beschriebenen Mikroresonatoren zu koppeln, um gezielt optisch und elektrisch gepumpte Einzelphotonenquellen für 1300nm zu realisieren. N2 - The research of quantum dots with their quantized, atom-like states provides many possibilities for quantum computing and for application in technologies like single photon sources and quantum dot lazers. Previous studies have demonstrated how quantum dots can be integrated with and linked to semiconductor resonator. For this reason, it is necessary to better understand and optimize the epitaxial growth of quantum dots. Within the context of this work, the Bragg-Resonators must be optimized so that Q factors of up to 165.000 can be realized. Extensive studies of these samplings indicate a complex dependency between Q factors and diameter of the micropillar. This is how a quasi-periodic Q factor oscillation looks. One factor for these oscillations is the composition of the side flanks of the resonator micropillars, caused by the various properties of AIAs and GaAs during processing the micropillar. In addition, both optically and electrically pumped single photon sources have been realized on the basis of this structure. Due to the fact that the position of the quantum dot within the resonator micropillar has a significant effect on the efficiency of the coupling between the resonator and the quantum dot, a further goal was to control the position of the quantum dot. With a precise positioning, it should be possible to place a micropillar directly over a quantum dot, thus the quantum dot is located in the center of the pillar mode. A particular challenge in the scope of work was to position the quantum dots with a distance of at least half of the target micropillar diameter,in other words, between 0,5μm and 2μm. The positioning must be done in such a way so that a AIAs/GaAs DBR micropillar can be processed over the quantum dot. Therefore processes were developed to place a lattice of holes on an MBE grown sample via Electron Beam Lithography. The lithographical process was optimized by additional steps of wet chemical cleaning, and cleaning with hydrogen under ultra high vacuum, to avoid defects during MBE overgrowth. InAs quantum dots have positions on a given structure in a distance of several micrometers to each other. It could be proved by processing gold pattern, that 30% of the quantum dots are placed within 50 nm precision and 60% within 100 nm . In the following work quantum dots have been placed in DBR micro pillars and photonic crystals. Because quantum dots have a wide spectral range and because they can be integrated in micropillars, they are also of interest for applications within telecommunication systems. Therefore the spectral range around 1300 nm and 1550 nm has to be re- ached to link them to fiber cable. Former studies have shown results tight under 1300nm. Nitrogen is an additional way to get InAs quantum emitting at 1300nm at 8 K. Until now research for InAs quantum dots containing nitrogen was focused on high density dots for laser application. The Dot- In-A-Well design was transferred, in this work, to this problem by using nitrogen in a well above the quantum dots. With this development, single quantum dots, emitting above 1300nm at 8 K, have been grown for the first time. The next step would be to integrated this InAs Quantum dots with the nitrogen well, within the micro pillar to achieve single photon sources at 1300nm. KW - Quantenpunkt KW - Molekularstrahlepitaxie KW - Mikroresonator KW - Drei-Fünf-Halbleiter KW - Optischer Resonator Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159024 ER - TY - THES A1 - Storz, Oliver T1 - Aufbau eines Rastertunnelmikroskops für Landau Level - Spektroskopie auf topologischen Isolator - Oberflächen T1 - Development of a scanning tunneling microscope for Landau level spectroscopy of topological insulator sufaces N2 - Im Rahmen dieser Arbeit wurde ein Rastertunnelmikroskop (STM) für Messungen bei tiefen Temperaturen und hohen Magnetfeldern konzipiert und aufgebaut. Die Probentemperatur kann dabei auf bis zu 1.4\,Kelvin reduziert werden, was spektroskopische Messungen mit extrem hoher Energieauflösung ermöglicht. Die thermische Verbreiterung spektroskopischer Merkmale liegt somit im Bereich eines Milli-Elektronenvolts, wie durch den Fit der Bandlücke eines supraleitenden Materials demonstriert wird. Ein linearer Bewegungsmechanismus ermöglicht die Positionierung des STM-Körpers innerhalb einer supraleitenden Spule, in der Magnetfelder von bis zu 12.5\,Tesla senkrecht zur Probenoberfläche erzeugt werden können. Das System erlaubt des Weiteren den Wechsel von Spitzen und Proben innerhalb des Kryostaten sowie das Aufdampfen von Einzelatomen auf die kalte Probenoberfläche ohne die Probe aus dem STM zu entfernen. Um den Einfluss mechanischer Vibrationen zu minimieren wurde ein innovatives Feder-Dämpfungssystem entwickelt, dass eine Stabilität des Tunnelkontakts von bis zu einem Pikometer gewährleistet. \\ \noindent Der zweite Teil dieser Arbeit präsentiert die Ergebnisse von STM-Messungen auf Antimon-Tellurid (Sb_{2}Te_{3}). Sb_{2}Te_{3}\, gehört zur relativ neu entdeckten Materialklasse der Topologischen Isolatoren (TI). Diese Verbindungen besitzen auf ihren Oberflächen Zustände mit linearer Dispersion, die durch die Zeitumkehr-Invarianz geschützt werden. Fokus unserer Messungen ist dabei der Einfluss eines magnetischen Feldes auf die Eigenschaften eines derartigen unkonventionellen 2D-Elektronengases. Dazu wurde die Entstehung von Landau Level (LL) innerhalb eines Magnetfelds genau untersucht. Die zwei in dieser Arbeit untersuchten Hauptaspekte sind: \medskip \noindent(i) Die energetische Verbreiterung, die Rückschlüsse auf die Lebensdauer zulässt\\ (ii) Die örtliche Fluktuation. \medskip \noindent Erstaunlicherweise kann die gemessene Verbreiterung der Landau Resonanzen nicht mit gängigen Mechanismen der Lebenszeit-Verbreiterung erklärt werden. Aus diesem Grund wird eine alternative Interpretation basierend auf der Heissenbergschen Unschärferelation vorgestellt, die im guten Einklang mit den von uns gewonnenen Daten steht. Des Weiteren zeigen örtlich aufgelöste Messungen systematische Abweichungen in der Dirac-Geschwindigkeit positiver und negativer Landau Resonanzen. Diese Fluktuationen stehen dabei in direktem Zusammenhang mit Änderungen im lokalen chemischen Potential. Da die physikalischen Ursachen dieser Abweichung im Rahmen dieser Arbeit nicht zweifelsfrei geklärt werden konnten, werden im letzten Teil die zugrundeliegenden Messergebnisse vorgestellt und mögliche Erklärungen des Verhaltens präsentiert. N2 - The scope of this thesis is the design and construction of a scanning tunneling microscope (STM) operating at low temperatures and high magnetic fields. The sample temperature can be reduced to 1.4\,Kelvin which permits to perform spectroscopic measurements with extremely high energy resolution. As demonstrated by fitting the gap of a superconducting material the thermal broadening of spectroscopic features is routinely found to be of the order of one milli-electronvolt. A linear travel mechanism allows to position the STM head inside a superconducting solenoid where magnetic fields up to 12.5\,Tesla can be applied perpendicular to the sample surface. Tips and samples can be exchanged in-situ and single atoms can be directly evaporated onto the cold sample surface without extracting the sample from the STM. To minimize the impact of mechanical vibrations, an innovative spring-damping system has been developed giving the tunneling junction a stability as low as one pico-meter. \\ \noindent The second part of this thesis presents the results of STM measurements on antimony telluride (\Sb_{2}Te_{3}). \Sb_{2}Te_{3}\, belongs to the relatively new class of materials known as topological insulators (TI). These compounds host on their surfaces linearly dispersing states which are protected by time-reversal symmetry. The focus of our measurements is the influence of a magnetic field on the properties of this unconventional 2D electron gas. The evolution of Landau levels (LL) in magnetic fields has been carefully analysed. Two are the main aspects which have been tackled: \medskip \noindent(i) Their energetic broadening, which can be directly linked to the lifetime \\ (ii) Their spacial fluctuation. \medskip \noindent Surprisingly, the energetic broadening of the landau peaks cannot be explained by any of the mechanisms commonly limiting the lifetime. An alternative interpretation based on Heissenberg's uncertainty principle is presented, which is found to be in good agreement with our data. Furthermore spatially resolved experiments reveal systematic deviations of the Dirac velocities for positive and negative LL. These fluctuations are intimately linked to variations of the local chemical potential. As the physical origin of this deviation could not be unambiguously identified, the last part presents the experimental data and suggests possible explanations of this finding. KW - Rastertunnelmikroskopie KW - Topologischer Isolator KW - Landau-Niveau KW - Rastertunnelspektoskopie Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-139525 ER - TY - THES A1 - Stichel, Thomas Günther T1 - Die Herstellung von Scaffolds aus funktionellen Hybridpolymeren für die regenerative Medizin mittels Zwei-Photonen-Polymerisation T1 - Fabrication of scaffolds of hybrid polymers for regenerative medicine using two photon polymerization N2 - In der vorliegenden Arbeit wurde das Verfahren der Zwei-Photonen-Polymerisation von anorganisch-organischen Hybridpolymeren (ORMOCER®e) untersucht. Untersuchungsschwerpunkte bildeten dabei die theoretischen Betrachtungen der Wechselwirkung zwischen Laser und Hybridpolymer, die experimentelle Charakterisierung unterschiedlicher ORMOCER®e sowie die Aufskalierung der Technologie im Hinblick auf die Herstellung von Scaffold-Strukturen für die regenerative Medizin. Hierbei wurde u. a. ein innovativer Belichtungsaufbau entworfen und aufgebaut, der es erlaubt makroskopische, poröse Scaffold-Strukturen mit minimalen Strukturgrößen im Bereich von wenigen Mikrometern herzustellen. ORMOCER®e sind typischerweise für optische Anwendungen konzipiert, weisen allerdings z. T. biokompatible Eigenschaften auf. Das Material ORMOCER® MB-47 wurde von M. Beyer eigens für biologische Anwendungen synthetisiert. Es zeichnet sich durch Biokompatibilität, teilweiser Biodegradierbarkeit und hervorragende Strukturierbarkeit durch die Zwei-Photonen-Polymerisation aus. Das in dieser Arbeit verwendete Mikrostrukturierungssystem beinhaltet im Wesentlichen einen Ultrakurzpulslaser, der 325 fs Pulse bei 1030 nm emittiert (verwendet wird die zweite Harmonische bei 515 nm), ein hochpräzises Positionierungssystem, bestehend aus drei luftgelagerten Lineartischen mit einer Reichweite von 10 cm (y-, z-Richtung) bzw. 15 cm (x-Richtung) sowie diversen Objektiven zur Fokussierung. Mit diesen Komponenten lassen sich komplexe dreidimensionale Strukturen mit minimalen Strukturgrößen von bis unter 100 nm erzeugen. In Kapitel 5.1 wurden theoretische Untersuchungen im Hinblick auf das Wechselwirkungsverhalten zwischen der fokalen Intensitätsverteilung und dem Materialsystem zur Bildung eines Voxels durchgeführt, wobei das technische Wechselwirkungsvolumen und das chemische Wechselwirkungsvolumen samt den reaktionskinetischen Abläufen separat betrachtet wurde. Das technische Wechselwirkungsvolumen beschreibt die Wechselwirkung zwischen der fokalen Intensitätsverteilung und dem Materialsystem im Rahmen eines Schwellwertprozesses, der es erlaubt Strukturdimensionen unterhalb des Beugungslimits zu realisieren. Die theoretischen Untersuchungen diesbezüglich ergaben, dass sphärische Aberrationen die fokale Intensitätsverteilung (Intensity-Point Spread Function (IPSF)) in Abhängigkeit der Belichtungskonfiguration z. T. sehr stark beeinflussen. Darüber hinaus wurde durch Betrachtung des Schwellwertverhaltens ein mathematischer Zusammenhang zwischen der IPSF und der Leistungsabhängigkeit der Charakteristik des technischen Wechselwirkungsvolumens geschaffen. Das chemische Wechselwirkungsvolumen beschreibt das tatsächliche Volumen der stattfindenden Polymerisationsreaktion. Dieses geht über das des technischen hinaus, was eine Folge von raumeinnehmendem Kettenwachstum im Rahmen von reaktionskinetischen Teilprozessen ist. Durch die Simulationen dieser reaktionskinetischen Abläufe wurde das leistungsabhängige, zeitliche Verhalten der Reaktionsteilnehmer (Radikale, Monomer, Photoinitiator) und des Vernetzungsgrades ermittelt. Die Simulation wurden für sehr kurze Belichtungszeiten (< 10 ms) auf der Basis von gekoppelten Differentialgleichungen nach Uppal & Shiakolas durchgeführt. Dabei wurde der Einfluss der Teilchendiffusion sowie der Temperaturentwicklung als gering erachtet und in den Berechnungen vernachlässigt. Die Simulationsergebnisse zeigen, dass eine geringe Belichtungszeit nicht unbedingt durch größere Laserleistungen ausgeglichen werden kann, um einen bestimmten Vernetzungsgrad zu erzielen. Vielmehr führt eine höhere Leistung zu einem raschen Verbrauch des Photoinitiators im Reaktionsvolumen und damit einem schnelleren Erliegen der Polymerisationsreaktion. Um dennoch hohe Vernetzungsgrade erzielen zu können, sind die Reaktionsgeschwindigkeitskoeffizienten der Propagation und der Terminierung k_P und k_T sowie eine ausreichende Photoinitiatorkonzentration von entscheidender Bedeutung. Je größer das Verhältnis k_P/k_T, desto höhere Vernetzungsgrade können auch bei kurzen Belichtungszeiten realisiert werden, wobei ein wesentlicher Teil der Polymerisation als Dunkelreaktion stattfindet. Diese Erkenntnis ist für die Aufskalierung der Technologie der Zwei-Photonen-Polymerisation von großer Bedeutung, welche mit einer Verkürzung der Belichtungszeiten einhergehen muss. Des Weiteren zeigen die Simulationen, dass das spatiale Konversionsprofil eines Voxels ein lokales Minimum im Zentrum aufweisen kann. Dieses Phänomen tritt dann auf, wenn aufgrund der applizierten Leistung, welche gemäß des Profils der IPSF im Zentrum am höchsten ist, der Photoinitiator im Zentrum rasch verbraucht wird. In Kapitel 5.2 wurde die Voxelbildung, das Vernetzungsverhalten sowie die mechanischen Eigenschaften belichteter ORMOCER®e bei unterschiedlichen Parametern und Materialsystemen experimentell untersucht. An Hand von Voxelfeldern wurden die Voxelgröße, das Aspektverhältnis und das Voxelvolumen bei unterschiedlichen Laserleistungen ermittelt. Die Ergebnisse wurden mit den berechneten technischen Wechselwirkungsvolumina verglichen, wobei die Differenz von tatsächlicher Voxelgröße und technischem Wechselwirkungsvolumen als eine weitere charakteristische Größe eingeführt wurde. Dabei zeigte sich, dass besonders die Voxellänge von der Länge des technischen Wechselwirkungsvolumens derart abweicht, dass dies nicht durch raumeinnehmendes Kettenwachstum im Rahmen der Reaktionskinetik erklärt werden kann. Mögliche Erklärungsansätze basieren hierbei auf Wechselwirkungseffekte zwischen Lichtfeld und Material. Beispielsweise könnten durch den nichtlinearen optischen Kerr-Effekt oder die Polymerisation selbst Brechzahlinhomogenitäten induziert werden, welche die Voxelbildung durch Selbstfokussierung beeinflussen. Der Unterschied der Voxelbreite, also das laterale chemische Voxelwachstum, zur Breite des technischen Wechselwirkungsvolumens wurde hingegen mit Hilfe der Reaktionskinetik erklärt. Dabei zeigte sich, dass dieser Unterschied sowohl vom Material selbst als auch von der Fokussieroptik abhängt. Des Weiteren wurde die Polymerisationsrate der unterschiedlichen Materialien aus der Auftragung des Voxelvolumens gegenüber der Laserleistung durch lineare Approximation bestimmt. Hierbei wurde festgestellt, dass die Materialsysteme z. T. erhebliche Unterschiede aufweisen. Als das Materialsystem mit der höchsten Polymerisationsrate hat sich das auf Acrylaten als vernetzbare Gruppen basierende OC-V in Kombination mit dem Irgacure® Oxe02 Photoinitiator herausgestellt. Aus diesem Grund wurde es für die Herstellung von makroskopischen Strukturen durch die Zwei-Photonen-Polymerisation bevorzugt verwendet. Die unterschiedlichen Materialien wurden ferner mit Hilfe der µ-Raman-Spektroskopie auf ihr Vernetzungsverhalten untersucht. Konkret wurden hierbei Linienfelder unter Variation der Scan-Geschwindigkeit und der Laserleistung mit Hilfe der 2PP hergestellt und vermessen. Die Vernetzungsgrade wurden semi-quantitativ aus den Spektren ermittelt. Insgesamt wurden Vernetzungsgrade im Bereich zwischen 40 % und 60 % gemessen, wobei mit OC-V und 2 Gew.-% Irgacure® Ox02 die höchsten Vernetzungsgrade erzielt wurden. Des Weiteren hat sich gezeigt, dass die Konversionsgrade für die jeweiligen Materialsysteme bei allen Scan-Geschwindigkeiten sich auf einem im Rahmen der Fehlergrenzen gleichem Niveau befinden. Damit kann der durch Simulationen theoretisch prognostizierte Abfall des Sättigungskonversionsgrades mit zunehmender Scan-Geschwindigkeit mit entsprechend variierenden Belichtungszeiten nicht als verifiziert angesehen werden. Die verschiedenen Materialsysteme wurden außerdem bezüglich ihrer mechanischen Eigenschaften charakterisiert. Zu diesem Zweck wurden zylindrische Formkörper unter verschiedenen Bedingungen (1PP, 2PP, verschiedene Photoinitiatorkonzentrationen) hergestellt und Druckfestigkeitsmessungen durchgeführt, sowie die Dichten und die Vernetzungsgrade aus den Formkörpern bestimmt. Insgesamt wurden Elastizitätsmodule im Bereich zwischen 0,40 und 1,37 GPa und Bruchfestigkeitswerte zwischen 117 bis 310 MPa ermittelt. Es konnte festgestellt werden, dass die Konzentration des Photoiniators das Vernetzungsverhalten und damit die mechanischen Eigenschaften der Formkörper stark beeinflusst. Während geringe Konzentrationen zu geringeren Vernetzungsgraden und niedrigen Elastizitätsmodulen führten, zeigten die Formkörper höherer Konzentration ein deutlich spröderes Verhalten mit höheren Vernetzungsgraden und Elastizitätsmodulen. Das höchste Elastizitätsmodul wurde an Hand von Formkörpern vermessen, welche aus OC-V mit 2 Gew.-% Irgacure® Ox02 hergestellt wurden. Darüber hinaus wurde festgestellt, dass sich die mechanischen Eigenschaften von durch 2PP hergestellten Formkörpern durch die applizierte Laserleistung beeinflussen lassen. Die Ursache hierfür ist, dass durch die Laserleistung die Voxelgröße und damit der Überlapp zwischen den Voxeln eingestellt werden kann. Im Bereich des Überlapps findet dann eine Doppelbelichtung des Materials statt, was zu höheren Vernetzungsgraden führen kann. Außerdem wurden durch die 2PP bei hinreichend großen Belichtungsleistungen auch Formkörper realisiert, welche höhere Elastizitätsmodule und Bruchfestigkeitswerte aufwiesen als Körper, welche durch UV-Belichtung hergestellt wurden. Die Aufskalierung der Zwei-Photonen-Technologie wurde in Kapitel 5.3 behandelt. Neben einer ausführlichen Diskussion zu den Herausforderungen diesbezüglich, wurden zwei Belichtungsstrategien zur Herstellung von makroskopischen Scaffold-Strukturen eingesetzt und optimiert. Hierbei ist insbesondere der Badaufbau hervorzuheben, der es erlaubte Strukturen von prinzipiell unbegrenzter Höhe mit Hilfe der Zwei-Photonen-Polymerisation herzustellen. Eine wesentliche Herausforderung der Aufskalierung der 2PP ist die Beschleunigung des Prozesses. Aus den Betrachtungen geht hervor, dass für eine gravierende Beschleunigung der 2PP-Strukturierung neben der Scan-Geschwindigkeit auch das Beschleunigungsvermögen des Positionierungssystems entscheidend ist. Des Weiteren sind auch Parallelisierungsmethoden mit z. B. diffraktiven optischen Elementen nötig, um ausreichende Prozessgeschwindigkeiten zu erzielen. Der Standardaufbau mit Luftobjektiven wurde dazu verwendet millimetergroße Strukturen mit hoher Qualität aus ORMOCER®en herzustellen. Auch wenn die maximale Strukturhöhe durch den Arbeitsabstand des Objektivs beschränkt ist, hat sich gezeigt, dass dieser Aufbau sich für die einfache Herstellung von millimetergroßen Test-Scaffold-Strukturen eignet, welche z. B. für Zellwachstumsversuche oder mechanische Belastungstest eingesetzt werden können. Das biodegradierbare MB-47 wurde hierbei ebenfalls erfolgreich eingesetzt und u. a. für die Herstellung von Drug-Delivery-Strukturen verwendet. Der Badaufbau, basierend auf einem Materialbad mit durchsichtigem Boden, einem darin befindlichen und in der Vertikalen (z-Richtung) beweglichen Substrathalter sowie einer Belichtung von unten durch eine sich in der Ebene bewegende Fokussieroptik, wurde verwendet um eine Freiheitsstatue mit 2 cm Höhe sowie millimetergroße Scaffold-Strukturen mit Porengrößen im Bereich von 40 bis 500 µm in ORMOCER-V zu realisieren. Weitere Strukturierungsresultate mit z. T. anwendungsbezogenem Hintergrund sind die Gehörknöchelchen des menschlichen Ohrs in Lebensgröße, ein Scaffold in Form eines Steigbügels des menschlichen Ohrs, Test-Scaffold-Strukturen für mechanische oder biologische Untersuchungen sowie Drug-Delivery Strukturen. Es wurden Bauraten von bis zu 10 mm^3/h erzielt. Bezüglich der Prozessgeschwindigkeit und Strukturhöhe wurde bei Weitem noch nicht das Potential des luftgelagerten Positioniersystems ausgeschöpft. Dafür bedarf es einer Gewichtsoptimierung des bestehenden Belichtungsaufbau, um höhere Beschleunigungswerte und Scan-Geschwindigkeiten realisieren zu können. Unter Annahme einer effektiven Gewichtsoptimierung und der damit verbundenen Erhöhung der Beschleunigung auf 10 m/s^2 könnte eine Baurate bei einer Scan-Geschwindigkeit von 225 mm/s und einem Slice- und Hatch-Abstand von 15 und 10 µm von etwa 60 mm^3/h erzielt werden. Im Rahmen der Aufskalierung wurde ebenfalls der experimentelle Einsatz von diffraktiven optischen Elementen zur Fokus-Multiplikation untersucht. Die Experimente wurden mit Hilfe eines Elements durchgeführt, welches eine 2 x 2 Punkte-Matrix neben der ungebeugten 0. Ordnung bereitstellt und Bestandteil eines experimentellen Setups war, welches aus Linsen, Blenden und einem Objektiv zur Fokussierung bestand. Mit Hilfe der erzeugten Spot-Matrix wurden zum einen simultan vier Drug-Delivery-Strukturen hergestellt und zum anderen einzelne Scaffold-Strukturen realisiert. In jedem Fall wurde eine Beschleunigung des Prozess bzw. eine Erhöhung der Polymerisationsrate um den Faktor 4 für die verwendeten Parameter erreicht. Bei der Herstellung der Scaffolds wurden zwei unterschiedliche Strategien verfolgt. Während zum einen die Periodizität der inneren Scaffold-Struktur auf die Fokusabstände angepasst und damit simultan vier aneinandergereihte Einheitszellen hergestellt wurden, konnte zum anderen auch demonstriert werden, dass durch die geschickte Bewegung der Fokusse eine ineinander verschobene Struktur möglich ist. Der Vorteil der letzteren Strategie ist, dass auf diese Weise eine komplette Schicht gescannt werden kann und damit hohe Scan-Geschwindigkeiten realisiert werden können. Die erzielten Bauraten waren dennoch nicht größer als die Bauraten, die mit einem einzelnen Spot im Rahmen des Standardaufbaus oder des Badaufbaus erreicht wurden. Hierfür bedarf es weiterer Optimierung der Parameter und des Setups. Transmittiert fokussiertes Licht eine Grenzfläche zweier Medien mit unterschiedlichen Brechungsindizes, dann tritt sphärische Aberration auf, welche sich durch die Verbreiterung des Fokus besonders in axiale Richtung bemerkbar macht. Da diese im Rahmen der verwendeten Belichtungsstrategien die Strukturierungsergebnisse nachweislich beeinträchtigen, wurden experimentelle Untersuchungen sowie Optimierungsroutinen diesbezüglich durchgeführt. Im Zusammenhang mit dem Standardaufbau wurde eine Leistungsanpassung während der Strukturierung vorgenommen. Auf diese Weise wurde erreicht, dass bei variabler Fokustiefe im Material die maximale Intensität trotz sphärischer Aberration konstant gehalten wurde, wodurch sich die strukturelle Homogenität der Scaffolds entlang der axialen Richtung (optische Achse) deutlich verbesserte. Des Weiteren wurde der Badaufbau dazu verwendet, die axiale Intensitätsverteilung in-situ für diskrete Fokustiefen unter der Verwendung eines Objektivs mit der NA von 0,60 abzubilden. Zu diesem Zweck wurde aus hergestellten Voxelfeldern eine Voxelfeldfunktion ermittelt und mit der axialen IPSF korreliert. Dabei wurde angenommen, dass sich das chemische Wechselwirkungsvolumen vernachlässigbar gering vom technischen Wechselwirkungsvolumen unterscheidet. Die experimentellen Ergebnisse zeigten deutlich die für sphärische Aberrationen typischen Nebenmaxima auf. Die Lage bzw. Abstände dieser entsprachen in guter Übereinstimmung den jeweiligen Simulationen. Schließlich wurde noch die sphärische Aberration durch den Korrekturring der Objektive für verschiedene Deckglasdicken korrigiert. Die resultierende IPSF wurde ebenfalls mit Hilfe des Badaufbaus abgebildet, wobei keinerlei Nebenmaxima gefunden werden konnten. Die Breite des Hauptmaximums konnte deutlich verringert werden. Zusammengefasst lässt sich sagen, dass im Rahmen dieser Arbeit erhebliche Fortschritte bei der Aufskalierung der 2PP zur Erzeugung von Scaffold-Strukturen für die regenerative Medizin erzielt wurden. Die erreichten Strukturdimensionen und die Bauraten übertreffen alle bis dato bekannten Ergebnisse. Dabei wurden auch durch theoretische Betrachtungen und experimentellen Methoden grundlegende Erkenntnisse über die Reaktionsdynamik der durch die Zwei-Photonen-Absorption initiierten Polymerisationsreaktion gewonnen. Nichtsdestotrotz sind einige Fragestellungen offen sowie Problematiken des Prozesses vorhanden, die für eine Realisierung von makroskopischen Scaffold-Strukturen gelöst werden müssen. So sind die realisierten Bauraten noch zu gering, um in angemessener Zeit makroskopische Scaffolds-Strukturen herzustellen, welche deutlich größer als 1 cm^3 sind. Aus diesem Grund müssen weitere Verbesserungen bezüglich der Scan-Geschwindigkeit sowie des Einsatzes von diffraktiven optischen Elementen zur Erhöhung der Polymerisationsrate erzielt werden. Da bei der Verwendung von Multi-Spot-Arrays, welche mit Hilfe gewöhnlicher diffraktiver optischer Elemente erzeugt wurden, die Realisierung von beliebigen und detaillierten äußeren Scaffold-Formen eingeschränkt ist, empfiehlt es sich den Einsatz von Spatial Light-Modulatoren zu verfolgen. Diese fungieren als dynamisch modulierbares DOE, mit dem einzelne Spots gezielt ein- und ausgeblendet und Spotabstände dynamisch variiert werden können. Schließlich ist es vorstellbar, den Spatial Light-Modulator mit dem Badaufbau zu kombinieren, um uneingeschränkte, große Strukturen in annehmbarer Zeit mit hochaufgelösten Details herstellen zu können. Dieses Vorgehen bedarf allerdings noch der tiefgreifenden Untersuchung der Potentiale des Spatial Light-Modulators. Darüber hinaus weisen die theoretischen und experimentellen Untersuchungen zur Reaktionskinetik darauf hin, dass die Voxelentstehung ein komplexer Prozess ist, der möglicherweise auch durch nichtlineare optische Wechselwirkungseffekte abseits der Zwei-Photonen-Absorption beeinflusst wird. Daher sind hier weitere Untersuchungen und Berechnungen zu empfehlen, um z. B. den Einfluss einer intensitätsabhängigen Brechzahl auf die Voxelbildung quantifizieren zu können. Entsprechende Ergebnisse könnten schließlich dazu dienen, dass im Rahmen dieser Arbeit entwickelte Modell zur Voxelbildung, welches auf der getrennten Betrachtung von technischen und chemischen Wechselwirkungsvolumen basiert, zu verbessern. Ein leistungsfähiges Modell, welches die Voxelbildung in Abhängigkeit des Materials und der Fokussieroptik präzise vorhersagen kann, wäre für das Erzielen optimaler Strukturierungsergebnissen ein Gewinn. N2 - In this thesis, the two photon polymerization technique using ORMOCER®s was investigated thoroughly. The main aspects of matter were the theoretical investigations of the interaction between laser and polymer, the experimental characterization of the different ORMOCER®s, and the scale-up of the photon polymerization technique in order to fabricate scaffolds for the regenerative medicine. The latter was achieved by designing and building up an innovative exposure device[38] which enables the fabrication of scaffold structures with minimal structure sizes of a view microns. The experiments were done using UV sensitive anorganic-organic hybrid polymers, also known as ORMOCER®s. These are typically synthesized for optical applications, but some are also biocompatible. The ORMOCER® MB-47 was invented by M. Beyer for biological application and possesses biocompatibility, partial biodegradability, and advanced 2PP structuring behavior. The micro-structuring system used contains an ultra-short pulse laser which emits 325 fs pulses at 1030 nm (applied was 515 nm using second harmonic generation), a highly precise positioning system which consists of three air-bearing stages with a travel range of 10 cm (y, z direction) and 15 cm (x direction), respectively, and some objectives for focusing. With these components, complex three-dimensional structures with minimal structure size below 1 µm can be produced. In Capital 5.1, theoretical studies of the interaction between the focal intensity distribution and the material, which defines voxel growth, were performed. Therefore, the technical interaction volume and the chemical interaction volume were separately investigated. The technical interaction volume describes the threshold driven interaction between the focal intensity distribution and the material system, which allows the realization of structure sizes below the resolution limit (diffraction) of the wavelength used. The theoretical investigations showed that spherical aberration influences the focal intensity distributions (Intensity-Point Spread Function (IPSF)) which were calculated for different experimental exposure configuration. The results propose a severe influence with increasing focus depth into the material. Moreover, a formal relation between the IPSF and the technical interaction volume was derived by using the threshold assumption. By using the Gaussian beam assumption as IPSF, the analogy of the derived formula to the voxel growth model of Serbin et al. was recognized. The chemical interaction volume represents the actual volume of the polymerization reaction. Its amount exceeds the technical interaction volume due to the space-consuming chain growth during the polymerization. By the simulation of the reaction kinetics of the polymerization, the time- and power-depending behavior of the different reactants (radicals, monomer, photo initiator) as well as the degree of conversion was calculated. The simulations were done for very short exposure times (< 10 ms) by using a system of coupled differential equations which are based on a model invented by Uppal & Shiakolas. Therefore, the influence of diffusion and temperature was estimated to be small on short time scales and thus neglected. The results of the simulations show that a short exposure time cannot be necessarily compensated by high laser powers to achieve a certain degree of conversion. Higher laser power leads rather to a swift consumption of the photo initiator and thus to a disruption of the polymerization. In order to achieve high degrees of conversions, the reactive rate coefficients of the propagation and termination k_P and k_T as well as a sufficient amount of photo initiator concentration is essential. The larger the ratio k_P/k_T the higher degree of conversion can be realized even with short exposure times whereas a significant part of the reaction takes place during the dark period. This finding is important for the scale-up of the photon polymerization technique which has to involve shorter exposure times. Moreover, the simulations show that the spatial profile of the degree of conversion can feature a central minimum. This phenomenon occurs when the central maximum intensity of the IPSF consumes the entire photo initiators in short times which leads to a disruption of the polymerization. In Capital 5.2, the voxel growth, the behavior of conversion as well as the mechanical properties of hardened ORMOCER®s were experimentally investigated with different parameters and material systems. By means of voxel fields, voxel sizes, aspect ratios and voxel volumes at different laser powers were determined. The results were compared with the calculated technical interaction volume, whereas the difference was invented as a new characteristic value. It has been shown that the voxel length deviates clearly from the length of the technical interaction volume which cannot be explained by space-consuming chain growth during the polymerization. Instead, it was assumed that this observation is reasoned by interaction effects between light and material (optical Kerr effect, polymerization) leading to an inhomogeneous refractive index distribution and thus to self-focusing and self-trapping. In contrast to that, the difference between the voxel diameter and the diameter of the technical interaction volume was correlated with reaction kinetic influences. Additionally, the dependency of the voxel volume on the laser power was linear approximated in order to determine the polymerization rate of different material systems. Here, strong differences between the materials were identified. The material with the highest polymerization rate was OC-V with the Irgacure® Oxe02 photo initiator which consists of acrylates as cross-linkable group. Because of this, this material system was preferred for 2PP structuring of large scale structures. The different materials were investigated concerning their conversion behavior by means of µ-Raman spectroscopy. Therefore, fields of lines were produced by 2PP with varying scan speed and laser power and measured. The degree of conversion was then semi-quantitative extracted from the spectra. All in all, the degrees of conversion were determined to be in the range of 40 to 60 % for all materials. The material with the highest degree of conversion was the OC-V with 2 wt.-% Irgacure® Ox02. Moreover, the measurements showed that the degree of conversion for each material system does not vary with the scan speed (exposure time) within the limits of measurement error. Thus, the simulations from Capital 5.1.3, which predicted that shorter exposure times cannot be necessarily compensated by higher laser powers, could not be confirmed. Furthermore, the mechanical properties of the different materials were characterized. Therefore, cylindrical samples were produced with different processes and parameters and tested with a compressive load. Also the densities and degrees of conversion were determined. All in all, elastic moduli between 0,40 and 1,37 GPa and load failures between 117 and 310 MPa were measured. It was detected that the photo initiator concentration influences the conversion behavior and thus the mechanical properties of the samples. While low concentrations led to lower degrees of conversion and lower elastic moduli, the samples produced with higher concentrations were more brittle with higher degrees of conversion and elastic moduli. The highest elastic modulus was measured for samples which were produced in OC-V with 2 wt.-% Irgacure® Ox02. Moreover, the mechanical properties of samples produced with 2PP can be influenced by the utilized laser power. This is reasoned by the voxel sizes which can be adjusted by the laser power and which determine the overlap of vicinal voxels at distinct hatch and slice distances. In the overlap area double exposure takes place which can lead to higher degrees of conversion. It was found that with sufficient laser powers the 2PP leads to higher elastic moduli and load failures than the 1PP. Capital 5.3 deals with the scale-up of the photon polymerization technique. After the discussion of the challenges, two exposure strategies were used to produce macroscopic scaffold structures. Especially, the vat setup has to be emphasized which can be used to build structures with basically unlimited structure heights by means of the 2PP technique. One of the major challenges concerning the scale-up of the 2PP is the speed-up of the process. Therefore, the scan speeds as well as the acceleration of the positioning system play important roles. Moreover it was detected that further parallelizing techniques as the utilization of diffraction optical elements are needed in order to achieve a sufficient speed-up of the 2PP technology. The standard exposure setup with air objectives was used to fabricate millimeter-sized structures in ORMOCER®s which high quality. Though the maximal achievable structure height is limited by the working distance of the objective used, the setup is suitable for the fabrication of macroscopic scaffolds which can be utilized for biological or mechanical testing. Moreover, the biodegradable MB-47 was successfully used for the fabrication of Drug Delivery structures. The vat setup bases on a vat/bath as material reservoir with transparent bottom, a sample holder moveable in the vertical (z) direction, and an upside down x-y-scanning objective. The sample can be moved upwards which enables one to build structures whose heights are not limited by the working distance of the employed objective anymore. This setup was used to fabricate a model of the statue of liberty with a height of 2 cm and millimeter-sized scaffolds with pore sizes in the area between 40 and 500 µm in ORMOCER®-V. Moreover, the human ossicles in life size, a scaffold in the shape of the human stapes, different test scaffold structures for mechanical and biological investigations and drug delivery structures were build. The achieved maximum building rate was 10 mm^3/h. So far, the speed-up and scale-up potentials of the air-bearing positioning system haven’t been exhausted when using the vat setup. Therefore, the setup has to be optimized regarding weight and stability in order to realize higher accelerations of up to 10 m/s^2. This would enable build rates of up to 60 mm3/h with a scan speed of 224 mm/s and slice and hatch distances of 15 and 10 µm. Moreover, the speed-up by means of diffractive optical elements was experimentally investigated. Therefore, an optical setup was constructed which includes the diffractive optical element, some lenses, an objective, and a blind to blank the zero order. By this a 2 x 2 spot matrix was generated which was used for the simultaneous fabrication of four drug delivery structures and the production of single scaffold structures. In both cases an increase of the polymerization rate was achieved regarding to structuring without diffractive optical elements. For the fabrication of the scaffold structures two different scan strategies were performed. Using the first one, a scaffold was built up by the simultaneous structuring of four scaffolds’ gyroid unit cells. After finishing these cells, more cells were stitched to them until a millimeter-sized scaffold was achieved. For this strategy, it’s important that the size of the unit cell design is adjusted to the focal matrix distances. With the second strategy a scanning of the whole spot matrix along the whole scaffold flank is performed. By this it was possible to produce a pile of interleaved beams which represents a woodpile-like scaffold. The fact that the produce lines of each layer are as long as scaffold flank leads to the advantage that higher scan speeds and thus build rates can be achieved than with the first strategy. Nevertheless, the realized maximum build rates weren’t exceeding the build rates which were reached by using the standard setup or the vat setup. Thus, more optimization of parameters and setup is needed. If focused laser lights transmits through an interface of two materials with different refractive indices, spherical aberration occurs which leads to blurring of the focal intensity distribution especially in the axial direction. When using air objectives this blurring affects the structuring results. Hence theoretical and experimental investigations were done in order to optimize exposure routines. When using the standard exposure setup, power adoption was performed during the structuring process which allows holding the maximum focal intensity constant at varying focal depths in the presence of spherical aberration influences. By this, a clear improvement of the scaffolds’ quality and homogeneity along the axial direction was achieved. Furthermore, the vat setup with the NA 0.60 objective was used to perform an experimental in situ mapping of the focal axial intensity distribution for different focal depths. A voxel field function was extracted from produced voxel fields and correlated with the axial intensity distribution. Therefore, it was assumed that the chemical interaction volume is equal to the technical interaction volume. The experimental results showed clearly the presence of side maxima which are typical for spherical aberration influences. The distances between them were predicted quite exactly by theoretical simulations. Finally, the spherical aberrations were reduced by the correction collar of the objective. The resulting intensity distribution was also mapped with the vat setup and no side maxima were found for the experimental intensity distribution. Moreover the contrast of the main maximum was clearly improved. Overall, it can be concluded that within this work a noticeable progress in the scale-up of the two-photon polymerization technique was achieved which is important for the fabrication of scaffold structures for the regenerative medicine. The realized structure dimensions and build rates exceed all, so far, known specifications of structures fabricated by two-photon polymerization. Moreover, basic knowledge of the most important aspects of the scale-up was discovered by thoroughly theoretical and experimental investigations. Nevertheless, there is still much improvement necessary to establish the two photon polymerization technique as a competitive tool for the production of scaffold structures which are larger than 1 cm^3. Higher scan speeds and advanced setups with diffractive optical elements must be applied to achieve build rates in the range over 1 cm^3/h. Due to the lack in flexibility of usual diffractive optical elements, it is recommended to use spatial light modulators which are dynamic adjustable diffractive optical elements. With them it is possible to vary the spot intensity distribution, spot number as well as the spot distances during the process. Finally, it is imaginable that in future the vat setup combined with a spatial light modulator can be used for the fabrication of large macro structures with finest details in adequate time. But therefore, it is necessary to perform thoroughly investigations concerning the potentials of spatial light modulators. Moreover, the theoretical and experimental investigations on the reaction kinetics show that voxel growth is a complex process which is possibly affected by nonlinear optical interactions aside from the two-photon absorption phenomenon. Thus, intensive study should be done in order to, for example, quantify the influence of an intensity-dependent refractive index on the voxel growth. Maybe, results could be used to improve the voxel growth model of this work which bases on the separate consideration of the technical and chemical interaction volumes. A powerful tool enabling the prices prediction of voxel growth characteristics depending on material and focusing optics would help to improve the detail quality of fabricated scaffolds. KW - Tissue Engineering KW - Polymere KW - Mikrofertigung KW - Two-photon polymerization KW - Two-photon absorption KW - Scaffold fabrication KW - Zwei-Photonen-Polymerisation KW - Zweiphotonenabsorption KW - Reaktionskinetik KW - Raman-Spektroskopie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-130161 ER - TY - THES A1 - Stender, Benedikt T1 - Einzelphotonenemitter und ihre Wechselwirkung mit Ladungsträgern in organischen Leuchtdioden T1 - Single Photon Emitters and their Interaction with Charge Carriers inside Organic Light Emitting Eiodes N2 - In dieser Arbeit wird die Photophysik von Einzelphotonenemittern unterschiedlicher Materialklassen, wie Fehlstellen in Diamant und Siliziumcarbid sowie organischer Moleküle bei Raumtemperatur untersucht. Zu diesem Zweck wurde ein hochauflösendes konfokales Mikroskop konzipiert und konstruiert, welches die optische Detektion einzelner Quantensysteme ermöglicht. Zusätzlich werden verschiedene Methoden wie die Rotationsbeschichtung, das Inkjet-Printing und das Inkjet-Etching in Bezug auf die Reproduzierbarkeit und Strukturierbarkeit von organischen Leuchtdioden (OLEDs) verglichen. Im weiteren Verlauf werden die optoelektronischen Prozesse in dotierten OLEDs untersucht, ausgehend von hohen Dotierkonzentrationen bis hin zur Dotierung mit einzelnen Molekülen. Dadurch kann die Exzitonen-Ladungsträger Wechselwirkung auf und in der Umgebung von räumlich isolierten Molekülen analysiert werden. N2 - In this work the room-temperature photophysics of single-photon sources of different material systems such as NV-centers, vacancies in silicon carbide and organic molecules are investigated. A high resolution home-built confocal microscope is used to detect and analyse the isolated single quantum emitters. Additionally, different methods and techniques for production of organic light emitting diodes (OLEDs) such as spin-coating, inkjet-printing and inkjet-etching are compared concerning their reproducibility and feasibility for structured OLED preparation. Subsequently, the opto-electronic processes in dye-doped polymeric OLEDs are examined for various doping concentrations ranging from high concentrations down to the doping by single molecules. This provides access to the investigation of the exciton-charge carrier interaction of single organic molecules in organic matrices. KW - Einzelphotonenquelle KW - Konfokale Mikroskopie KW - OLED KW - Single Photon Sources KW - confocal microscopy KW - Einzelphotonenemission KW - Konfokale Mikroskopie KW - OLED KW - Ladungsträger Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150913 ER - TY - THES A1 - Steindamm, Andreas T1 - Exzitonische Verlustmechanismen in organischen Bilagen-Solarzellen T1 - Excitonic loss mechanisms in organic bilayer solar cells N2 - Um die Wirkungsgrade organischer Solarzellen weiter zu steigern, ist ein Verständnis der auftretenden Verlustmechanismen entscheidend. Im Vergleich zu anorganischen photovoltaischen Zellen sind in den organischen Halbleitern die durch Absorption erzeugten Elektron-Loch-Paare, die als Exzitonen bezeichnet werden, sehr viel stärker gebunden. Daher müssen sie an einer Heterogrenzfläche, gebildet durch ein Donator- und ein Akzeptormaterial, in freie Ladungsträger getrennt werden. Mit dem erforderlichen Transportweg an die Heterogrenzschicht sind Rekombinationsverluste der exzitonischen Anregungen verbunden, die aus einer Vielzahl unterschiedlicher Prozesse resultieren und einen der Hauptverlustkanäle in organischen Solarzellen darstellen. Aus diesem Grund wird der Fokus dieser Arbeit auf die Charakterisierung und mögliche Reduzierung solcher exzitonischen Verlustmechanismen gelegt. Als Modellsystem wird dazu eine planare Bilagen-Struktur auf Basis des Donatormaterials Diindenoperylen (DIP) und des Akzeptors Fulleren C60 verwendet. Durch die Kombination von elektrischen und spektroskopischen Messmethoden werden unterschiedliche exzitonische Verlustmechanismen in den aktiven Schichten charakterisiert und die zugrunde liegenden mikroskopischen Ursachen diskutiert. Dazu wird zuerst auf die strukturellen, optischen und elektrischen Eigenschaften von DIP/C60-Solarzellen eingegangen. In einem zweiten Abschnitt werden die mikroskopischen Einflüsse einer Exzitonen blockierenden Lage (EBL, exciton blocking layer) aus Bathophenanthrolin (BPhen) durch eine komplementäre Charakterisierung von Photolumineszenz und elektrischen Parametern der Solarzellen untersucht, wobei auch die Notwendigkeit der EBL zur Unterbindung von Metalleinlagerungen in den aktiven organischen Schichten analysiert wird. Die anschließende Studie der Intensitäts- und Temperaturabhängigkeit der j(U)-Kennlinien gibt Aufschluss über die intrinsischen Zellparameter sowie die Rekombinationsmechanismen von Ladungsträgern in den aktiven Schichten. Ferner werden durch temperaturabhängige spektroskopische Untersuchungen der Photo- und Elektrolumineszenz der Solarzellen Informationen über die elektronischen Zustände der DIP-Schicht erlangt, die für Rekombinationsverluste der generierten Exzitonen verantwortlich sind. Zusätzlich werden Raman-Messungen an den Solarzellen und Einzelschichten diskutiert. In einer abschließenden Studie werden exzitonische Verluste unter Arbeitsbedingungen der Solarzelle durch Ladungsträgerwechselwirkungen in der Donator-Schicht quantifiziert. In dieser Arbeit konnten verschiedene relevante Verlustprozesse in organischen Solarzellen reduziert werden. Durch die Identifizierung der mikroskopischen Ursachen dieser Verluste wurde eine wichtige Voraussetzung für eine weitere Steigerung der Leistungseffizienz geschaffen. N2 - To increase the efficiencies of organic solar cells, understanding of the occurring loss mechanisms is crucial. In comparison to inorganic photovoltaic cells the electron hole pairs, referred to as excitons, are bound much stronger in organic semiconductors. Therefore dissociation into free charge carriers takes place at a hetero interface of a donor and an acceptor material. The necessary diffusion path to this interface entails recombination loss mechanisms resulting from diverse processes which represent one of the main loss channels in organic solar cells. Thus the focus of this work is set on the characterization and potential reduction of such excitonic loss mechanisms. As a model system planar heterojunction solar cells consisting of diindenoperylene (DIP) as donor and fullerene C60 as acceptor material were used. By combining electrical with spectroscopic measurement techniques diverse excitonic loss mechanisms in the active layers are characterized and the underlying microscopic processes are discussed. Firstly the structural, optical and electrical properties of the DIP/C60 solar cells are observed. In a second section the microscopic effects of an exciton blocking layer (EBL) consisting of bathophenanthroline (BPhen) are investigated by a complementary analysis of photoluminescence and electrical parameters of the solar cells. In doing so also metal penetration into the active organic layers is analyzed and effectively suppressed. The following study of intensity and temperature dependent j(V) characteristics reveals intrinsic cell parameters as well as recombination mechanisms of charge carriers in the active layers. Moreover information about the electronic states of the DIP layer responsible for recombination losses is obtained by temperature dependent spectroscopic analyses of photo- and electroluminescence of the solar cells. Additionally Raman spectra of solar cells and the individual organic thin films are discussed. Finally excitonic losses in solar cells at working conditions due to charge carrier interaction are quantified for the donor layer. During this work diverse relevant loss mechanisms in organic solar cells could be reduced. By identifying the microscopic origins of such losses an important prerequisite was set for further power efficiency enhancement of organic photovoltaic cells. KW - Organische Solarzelle KW - Exziton KW - Diindenoperylen KW - diindenoperylene KW - C60 KW - Bathophenanthrolin KW - bathophenanthroline KW - Bilagen-Solarzelle KW - exciton blocking layer KW - Rekombination KW - Photolumineszenz KW - Elektrolumineszenz KW - Raman-Spektroskopie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124002 ER - TY - THES A1 - Stahlhut, Philipp T1 - Konzeption und Aufbau einer Nanofokus Labor CT Anlage in Reflexionsgeometrie auf Basis eines Rasterelektronenmikroskops T1 - Design and construction of a nanofocus laboratory CT system in reflection geometry based on a scanning electron microscope N2 - In der vorliegenden Arbeit werden die Konzeption und Realisierung eines Computertomographen zur Materialanalyse auf Basis eines Rasterelektronenmikroskops mit einem räumlichen Auflösungsvermögen im Nanometerbereich diskutiert. Durch einen fokussierten Elektronenstrahl, der mit einer Beschleunigungsspannung von 30 kV auf eine mikrostrukturierte Wolframnadel mit einem Spitzenradius von bis zu 50 nm gezielt wird, entsteht ein kleiner Röntgenbrennfleck über den mit geometrischer Vergrößerung hochauflösende Projektionen eines zu untersuchenden Objekts erzeugt werden. Durch Rotation des Testobjekts werden Projektionen aus verschiedenen Blickwinkeln aufgenommen und über einen speziellen Rekonstruktionsalgorithmus zu einem 3-dimensionalen Bild zusammengefügt. Bei der Beurteilung der Einzelkomponenten des Geräts wird insbesondere auf Struktur, Form und den elektrochemischen Herstellungsprozess der Röntgenquelle eingegangen. Eine ausreichend genaue Positionierung von Messobjekt und Röntgenbrennfleck wird über Piezoachsen realisiert, während die Stabilität des Röntgenbrennflecks über die Elektronenoptik des Rasterelektronenmikroskops und die Form der Quellnadel optimiert wird. Das räumliche Auflösungsvermögen wird über die Linienspreizfunktion an Materialkanten abgeschätzt. Für eine Wolfram-Block-Quelle ergibt sich dabei ein Auflösungsvermögen von 325 nm – 400 nm in 3D, während der Quellfleck einer Wolframnadel das Auflösungsvermögen der Anlage auf 65 nm – 90 nm in 2D und 170 nm – 300 nm in 3D bei Messungen an einem AlCu29-Testobjekt anhebt. Außerdem werden die Auswirkungen der Phasenkontrastcharakteristik der Röntgenquelle auf die rekonstruierten Bilder nach Anwendung eines Paganin-Filters diskutiert. Dabei zeigt sich, dass durch Anwendung des Filters ein verbessertes Signal-zu-Rausch-Verhältnis auf Kosten der räumlichen Bildauflösung erzielt werden kann. Eine Vergleichsmessung mit einem kommerziell verfügbaren Röntgenmikroskop zeigt die Stärken des vorgestellten Systems bei Untersuchung von stark absorbierenden Messobjekten. Das kompakte Design erlaubt eine Weiterentwicklung in Richtung eines nanoCT-Moduls als Upgrade Option für Rasterelektronenmikroskope im Gegensatz zu den weitaus teureren bisher verbreiteten nanoCT-Geräten. N2 - The presented thesis discusses the conceptual design and realization of a computed tomography system for material analysis based on a scanning electron microscope with a spatial resolution in the nanometer range. A focused electron beam accelerated through a field of 30 kV aimed at a microstructured tungsten needle with a tip radius of up to 50 nm creates a small X-ray focal spot enabling high-resolution projections of an object via geometric magnification. By rotating the object, projections from different angles are recorded and combined into a 3-dimensional image using a special reconstruction algorithm. When assessing the individual components of the device, particular attention is paid to the structure, shape and the electrochemical manufacturing process of the X-ray source. Sufficiently accurate positioning of the sample and the X-ray focal spot is realized via piezo axes, while the stability of the focal spot is optimized via the electron optics of the scanning electron microscope and the shape of the source needle. The spatial resolution is estimated via the line spread function at material edges. For a tungsten block source, this results in a spatial resolution of 325 nm – 400 nm in 3D, while the source spot of a tungsten needle increases the spatial resolution of the system to 65 nm – 90 nm in 2D and 170 nm – 300 nm in 3D for measurements on an AlCu29 test object. In addition, the effects of the phase contrast characteristics of the X-ray source on the reconstructed images after applying a Paganin phase retrieval filter are discussed. It is shown that by applying the filter, an improved signal-to-noise ratio can be achieved at the expense of spatial image resolution. Comparable measurements with a commercially available X-ray microscope shows the strengths of the presented system when investigating strongly absorbing samples. The compact design allows development towards a nanoCT-module as an upgrade option for scanning electron microscopes, reaching a similar resolution as the nanoCT-devices that are commercially available up to now but at reduced costs. KW - Computertomographie KW - Rasterelektronenmikroskopie KW - Nanometerbereich KW - Laborgerät KW - Materialanalytik KW - Reflexionsgeometrie Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-302648 ER - TY - THES A1 - Stahl, Andreas T1 - Röntgenstrukturuntersuchungen an spintronischen Halbleiter- und Halbmetall-Dünnschichtsystemen T1 - X-ray analysis of spintronic semiconductor and half metal thin film systems N2 - In dieser Arbeit wurden die strukturellen Eigenschaften von spintronischen Halbleiter- und Halbmetall-Dünnschichtsystemen untersucht. Mit Röntgenreflektivitätsmessungen konnten die Schichtdicken und Grenzflächenrauigkeiten der Mehrschichtsysteme sehr genau bestimmt werden. Hierfür wurde die Software Fewlay verwendet, welche den Parratt-Formalismus zur Berechnung der Reflektivität nutzt. An reziproken Gitterkarten, die an möglichst hoch indizierten Bragg-Reflexen gemessen wurden, konnte das Relaxationsverhalten der Schichtsysteme untersucht werden. N2 - In this work the structural properties of spintronic semiconductor and halfmetalic thinfilm systems were investigated. The layer thicknesses and interface routhnesses of the multi-layer systems were estimated by X-ray reflectivity measurements. The fits were performed using the software Fewlay which uses the parratt formalism to calculate the reflectivities. The relaxation of the films was analyzed by reciprocal space mapping on preferably highly indexed bragg reflexes. KW - Halbleiterschicht KW - Spintronik KW - Röntgenstrukturanalyse KW - Halbmetall KW - Röngenbeugung KW - semiconductor KW - half metal KW - x-ray diffraction Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-49309 ER - TY - THES A1 - Stadler, Christoph T1 - Strukturuntersuchungen organischer Monolagen auf Ag(111) T1 - Structural investigations of organic monolayers on Ag(111) N2 - In dieser Arbeit wurden zwei komplementäre Beugungsverfahren verwendet, um die geometrische Struktur von organischen Adsorbaten (NTCDA und verschiedenen Metall-Pcs) auf Ag(111) zu untersuchen: um die lateralen Strukturparameter zu messen wurde hochauflösende Beugung niederenergetischer Elektronen (SPALEED) verwendet. Die vertikalen Abstände der einzelnen atomaren Spezies von der Silberoberfläche wurden mit der Methode der Absorption in stehenden Röntgenwellenfeldern (XSW) bestimmt. Aus den Arbeiten von Kilian et al. [43, 42] ist bekannt, daß die relaxierte und komprimierte Monolage NTCDA/Ag(111) einen Ordnungs-Unordnungs-Phasenübergang beim Abkühlen besitzt. Dazu sollten zu Beginn dieser Arbeit stabile Parameter mithilfe von Kühlversuchen unter Beobachtung im LEED gefunden werden, um diesen Phasenübergang zu reproduzieren. Dies ist nicht gelungen. Es wurden aber die vertikalen Abstände der Kohlenstoff- und Sauerstoffatome der relaxierten Monolage zum Substrat mithilfe von XSW bestimmt. Diese bestätigen die Messungen von Stanzel et al. [88, 87], die aufgrund des geringen Abstandes auf Chemisorption schließen lassen. Darüberhinaus wurde die Methode von Stanzel et al. verfeinert, das Photoelektronensignal (O1s) und das Auger-Signal (OKLL) kohärent zu interpretieren. Dabei wurden sowohl die nichtdipolaren Parameter der Photoemission (O1s) als auch der Anteil der durch Sekundärelektronen induzierten Augerzerfälle (OKLL) berücksichtigt und iterativ angepasst. Im Fall von NTCDA ist es möglich, anhand der Peakstruktur der O1s-Photoelektronen die Anhydridsauerstoffe von den Carbonylsauerstoffen zu trennen. Diese wurden bei XSW als getrennte Detektionskanäle verwendet und zeigen für die relaxierte Monolagenstruktur von NTCDA/Ag(111) - ähnlich wie schon von Hauschild et al. für PTCDA/Ag(111) [29, 30] gemessen - daß die Carbonylsauerstoffe in den Ecken des NTCDA-Moleküls um ca. 0:10 näher am Substrat liegen als die Anhydridsauerstoffe in der Brückenposition. Solch detaillierten Messungen sind notwendig, um für die Vielzahl von verschiedenen theoretischen ab-initio Methoden und Näherungsrechnungen ein Maß für deren Genauigkeit bereitzustellen. Bei den relativ großen Einheitszellenund der deshalb hohen Anzahl von Elektronen im organischen Molekül und den darunterliegenden Silberatomen haben diese Methoden noch Schwierigkeiten in endlicher Zeit akkurate Ergebnisse zu liefern. Der Hauptteil der Arbeit beschäftigte sich mit der geometrischen Struktur von Metall-Phthalocyaninen auf Ag(111). Das Phasendiagramm der Submonolagenstrukturen von SnPc/Ag(111) besteht im wesentlichen aus drei Bereichen in Abhängigkeit der Bedeckung und der Temepratur: Bei Raumtemperatur liegt bei niedrigen Bedeckungen unterhalb von ca. 0.9ML eine gasförmige Phase vor. Zwischen 0.9ML und 1 ML treten inkommensurable Strukturen auf, deren geometrische Parameter mit der Bedeckung variieren. Bei beiden Phasen nimmt der intermolekulare Abstand kontinuierlich mit der Bedeckung ab. Zumindest bei den inkommensurablen Phasen ist das ein klarer Beweis für eine Repulsion zwischen den Molekülen. Bei tiefen Temperaturen (<45°C) gibt es in einem mittleren Bedeckungsbereich (0.5ML - 0.92ML) eine kommensurable Überstruktur mit zwei Molekülen pro Einheitszelle. Es ist sogar möglich, von der inkommensurablen Phase (0.9ML...0.92ML) durch Temperaturabsenkung zu dieser etwas dichter gepackten kommensurablen Phase zu gelangen - die Repulsion lässt sich also nur mit Hilfe einer Temperaturänderung in eine Attraktion zwischen den Molekülen umschalten. Aufgrund der Abstände der verschiedenen Spezies zum Silbersubstrat konnte die Orientierung der Moleküle zum Substrat in den verschiedenen Phasen gemessen werden. Sie deuten auf eine chemisorptive Anbindung der Moleküle. Interessanterweise liegen die Moleküle in der Monolage alle mit dem Sn-Atom zum Substrat, während das Sn-Atom in der kommensurablen Tieftemperaturphase alternierend zum Substrat hinund wegzeigt. Diese Messungen erlauben eine Begründung der Attraktion und Repulsion zwischen den Molekülen auf Basis eines Donations-Rückdonationsmodells der Bindung der Moleküle an das Substrat. Sie werden mit den Ergebnissen von CuPc/Ag(111) von Ingo Kröger verglichen [46]. Schließlich werden noch erste Messungen an TiOPc vorgestellt. Die Datenlage bei TiOPc ist noch weniger dicht, es zeigt aber ein ähnliches Verhalten. Der augenfälligste Unterschied zu SnPc ist wohl die stabile Bi-Lage im Fall des TiOPc/Ag(111), die sich nicht durch Tempern vollständig ablösen lässt - im Gegensatz zu SnPc/Ag(111). Diese ersten geometrischen Messungen stimulierten neben weiteren SPALEED und XSW Messungen [46, 85] eine Reihe weiterer Untersuchungen in der Gruppe wie UPS, Austrittsarbeitsänderungen und detaillierte XPS-Messungen an den Rumpfelektronen, die das Donations-Rückdonationsmodell und die Orientierung der Moleküle bestätigen [108, 71]. N2 - In order to study the geometry of organic Adsorbates (NTCDA and different Metal-Pcs) on Ag(111) two complementary methods were used: the lateral structural parameters were explored via high resolution low energy electron diffraction (SPALEED), the vertical distances of the different atomic species to the substrate were measured with the method of absorption profiles in x-ray standing waves (XSW). NTCDA/Ag(111) forms a relaxed and a compressed monolayer structure and shows an order-disorder phase transition upon cooling [43, 42]. In the beginning of this work the aim was to and stable parameters for this phase transition upon cooling with LEED, which was not succesful. In addition, the vertical distances of the carbon and oxygen atoms of the relaxed monolayer to the substrate was determined with XSW. These measurements confirmed the results of Stanzel et al. [88,87] which indicates a chemisorption because of the relatively small bonding lenghts. His method of using both, the photoelectron signal (O1s) and Auger signal (OKLL) for a coherent interpretation of the distances was refined. Therefore, the non-dipolar parameters of the photoemission (O1s) and the portion of secondary electron induced Auger (OKLL) were taken into account and iteratively adjusted. In the case of NTCDA/Ag(111) the O1s-peak structure allows to distinguish between anhydride and carbonyl oxygen signals. These signals have been used as independant absorption channels in the XSW-experiment and show that the carbonyl oxygens in the edge of the molecule are about 0.1Å closer to the substrate than the anhydride oxygen in the bridge position - a result similar to PTCDA/Ag(111) measured by Hauschild et al. [29, 30]. The big variaty of theoretical ab-initio calculations and approximations need such detailed input in order to evaluate the quality of these calculations. The relatively big unit-cells and therefore the high number of electrons in the organic molecules and the underlying silver atoms is a big hurdle to get accurate theoretical results in limited timeframes. The main part of this work is dedicated to the geometrical structure of different metal phthalocyanines on Ag(111). The phase diagram of the submonolayer structures of SnPc/Ag(111) shows three different parts as a function of coverage and temperature: at room temperature at lower coverages (<0.9ML) a gaseous phase appears. Between 0.9ML and 1ML incommensurate structures appear, which change their geometric parameters continously with coverage. In both phases the intermolecular distances decrease continously with coverage. At least for the incommensurate phases, this clearly proofs intermolecular repulsion. At low temperatures (<45°C) in a medium coverage region (0.5ML - 0.92ML) a commensurate structure with two molecules per unit cell occurs. It is even possible to change from the incommensurate phase (0.9ML...0.92ML) to the slightly denser packed commensurate phase via cooling: The intermolecular repulsion changes to attraction only via a temperature change. With the distance of the different species in the molecule the orientation of the molecule to the substrate could be determined for the different phases. The distances themselves indicate a chemisorption of the molecules to the Ag(111) surface. Interestingly, the molecules in the monolayer are all in „Sn-down“-configuration, whereas the molecules in the commensurate phase alternate in „Sn-up“- and „Sn-down“-configuration. These measurements allow an interpretation of the attraction and repulsion in between the molecules on a donation/back donation model of the chemisorption of the molecule to the substrate. These measurements are compared to the results on CuPc/Ag(111) of Ingo Kröger [46]. At last, first measurments on TiOPc/Ag(111) are presented. The data collection in the phase diagram is much less dense than in the case of SnPc. However, a similar behavior is already seen. The most prominent difference between SnPc and TiOPc is the stable bi-layer in the case of TiOPc, which cannot be removed via annealing - in contrast to the case of SnPc/Ag(111). These first geometric measurements stimulated other expermiment in our group on these systems like UPS, core-level XPS and determination of the work function which all are in favor of this donation/backdonation model and the different configurations of the molecules in the phase diagram [108, 71]. Also SPALEED and XSW measurements have been continued [46, 85]. KW - LEED KW - Monoschicht KW - Chemisorption KW - Ordnungs-Unordnungs-Umwandlung KW - Oberflächenphysik KW - stehende Röntgenwellenfelder KW - Repulsion organischer Moleküle KW - Repulsion of organic molecules KW - XSW KW - LEED KW - phase transition KW - chemisorption Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-35930 ER - TY - THES A1 - Sperlich, Andreas T1 - Electron Paramagnetic Resonance Spectroscopy of Conjugated Polymers and Fullerenes for Organic Photovoltaics T1 - Elektron-Paramagnetische Resonanz-Spektroskopie von konjugierten Polymeren und Fullerenen für die organische Photovoltaik N2 - In the presented thesis, the various excited states encountered in conjugated organic semiconductors are investigated with respect to their utilization in organic thin-film solar cells. Most of these states are spin-baring and can therefore be addressed by means of magnetic resonance spectroscopy. The primary singlet excitation (spin 0), as well as positive and negative polaronic charge carriers (spin 1/2) are discussed. Additionally, triplet excitons (spin 1) and charge transfer complexes are examined, focussing on their differing spin-spin interaction strength. For the investigation of these spin-baring states especially methods of electron paramagnetic resonance (EPR) are best suited. Therefore according experimental methods were implemented in the course of this work to study conjugated polymers, fullerenes and their blends with continuous wave as well as time-resolved EPR and optically detected magnetic resonance. N2 - Die vorliegende Arbeit beschäftigt sich mit den vielfältigen Anregungszuständen in konjugierten organischen Halbleitern mit Hinblick auf deren Verwendung in organischen Dünnschicht-Solarzellen. Diese verschiedenen Zustände sind zumeist Spin-behaftet und daher mit Methoden der Magnetresonanz adressierbar. Es wird unterschieden zwischen Singulett-Exzitonen (Spin 0) als primärer Photoanregung, sowie positiven und negativen polaronischen Ladungsträgern (Spin 1/2). Des Weiteren werden Triplet-Exzitonen (Spin 1) und Ladungstransferkomplexe behandelt, die sich durch unterschiedlich starke Spin-Spin Wechselwirkung auszeichnen. Zur Untersuchung dieser Spin-behafteten Zustände bieten sich insbesondere Methoden der Elektron-Paramagnetischen Resonanz-Spektroskopie (EPR) an. Im Zuge dieser Arbeit wurden dafür entsprechede Messmethoden der Dauerstrich (cw) EPR, zeitaufgelösten, transienten EPR und der optisch detektierten Magnetresonanz (ODMR) implementiert und zur Erforschung von konjugierten Polymeren, Fullerenen und deren Mischungen eingesetzt. KW - Organische Solarzelle KW - Fotovoltaik KW - Organischer Halbleiter KW - organische Photovoltaik KW - organische Halbleiter KW - organic photovoltaic KW - organic solar cells KW - Elektronenspinresonanz KW - Fullerene KW - Konjugierte Polymere KW - Photovoltaik KW - Spektroskopie Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-81244 ER - TY - THES A1 - Spanheimer, Daniela Cornelia T1 - Dynamische Leistungsverstärkung bei GHz Frequenzen und Speichereigenschaften von nanoelektronischen GaAs/AlGaAs Transistoren T1 - Dynamic power gain at GHz frequencies and memory effects of nanoelectronic GaAs/AlGaAs transistors N2 - Es wurde gezeigt, dass durch die Vorpositionierung von Quantenpunkten, diese mit einem gezielten Abstand im Bereich von einigen 100 nm zueinander und daher mit einer definierten Dichte in Speicherbauelemente eingebracht werden können. Es wurde bei tiefen Temperaturen wohldefinierte Coulombblockade demonstriert. Durch die Analyse der Coulomb-Rauten war es möglich, auf die Größe und Ladeenergie von Quantenpunkten im Kanal zu schliessen. Es wurde gezeigt, dass vorpositionierte Quantenpunkte sehr gut als Floating Gate eingesetzt werden können. Die Speichereigenschaften dieser Quantenpunkte wurden im Hinblick auf die Hysteresebreite DeltaVth in Abhängigkeit der Kanalbreite, der Drainspannung und der Temperatur untersucht und diskutiert. Hierbei konnte eine deutliche Abhängigkeit der Thresholdspannung von der Kanalbreite der Struktur ermittelt werden. Für Strukturen mit einem breiten Kanal wurde festgestellt, dass der Stromfluss bereits bei negativen Gatespannungen einsetzt, während für schmale Strukturen positive Gatespannungen nötig sind, um einen Ladungstransport hervorzurufen. Zur Bestimmung der Temperaturstabilität der Ladezustände wurde sowohl die Thresholdspannung als auch die Hysteresebreite als Funktion der Probentemperatur im Bereich von 4.2K bis Raumtemperatur bei verschiedenen Drainspannungen bestimmt. Hierbei wurde festgestellt, dass die Hysteresebreite bis zu einer kritischen Temperatur stufenförmig abnimmt und danach wieder leicht ansteigt. Bei der Untersuchung der Threshold- Spannung wurde ein Unterschied Vth,zu und Vth,auf festgestellt. Erstmals konnte ein lateral und vertikal positionierter InAs Quantenpunkt als Speicher für den Betrieb bei Raumtemperatur demonstriert werden. Ferner wurde die Wirkung eines Gate-Leckstromes auf den gemessenen Drain- Strom eines monolithischen Drei-Kontakt-Struktur untersucht und diskutiert. Die untersuchten Proben basieren auf einem neuen Parallel-Design, in welchem das Gate nicht wie üblich zwischen Source und Drain positioniert wurde, sondern in serieller Verbindung mit dem Drain- oder Sourcekontakt, d.h. mit einem zentralen Drain zwischen Source und Gate, gesetzt wurde. Hierdurch konnte eine merkliche Reduzierung des Probeninnenwiderstandes erreicht werde. Zu Beginn wurden zur Charakterisierung der Probe Transportmessungen bei Raumtemperatur durchführt. Hierbei konnte verglichen mit herkömmlichen Quantendrahttranistoren realisiert auf demselbenWafer, zum einen eine deutlich höhere Transconductance durch das parallele Design erreicht werden. Zum anderen zeigte die ermittelte Transconductance nicht den erwarteten linearen Verlauf in Abhängigkeit der Drainspannung, sondern einen quadratischen. Die Messungen zeigten außerdem einen Abfall des Drain-Stromes ab einer kritischen Größe des Gate-Leckstromwertes, welcher auf ein dynamisches Gate, hervorgerufen durch die Ladungsträger aus dem Gate, zurückgeführt wird. Diese zusätzliche virtuelle Kapazität addiert sich in paralleler Anordnung zum geometrischen Gate-Kondensator und verbessert die Transistoreigenschaften. Zum Abschluss der Arbeit wurden Hochfrequenzmessungen zur Ermittlung einer Leistungsverstärkung von Drei-Kontakt-Strukturen bei Raumtemperatur für unterschiedliche Gate- und Drainspannungen durchgeführt. Um die Hochfrequenzeigenschaften der untersuchten Probe zu erhöhen, wurde hierfür ein Design gewählt, in welchem die Goldkontakte zur Kontaktierung sehr nahe an die aktive Region heranragen. Für diese Spannungskombination konnte für eine Frequenz im Gigaherz-Bereich eine positive Spannungsverstärkung > 1 dB gemessen werden. Höhere Spannungen führen zu einem Sättigungswert in der Leistungsverstärkung. Dies wird zurückgeführt auf den maximal zur Verfügung stehenden Strom in der aktiven Region zwischen den nahen Goldkontakten. Zudem wurde eine Lösung vorgestellt, um das fundamentale Problem der Impedanzfehlanpassung für Hochfrequenzmessungen von nanoelektronischen Bauelementen mit einem hohen Innerwiderstand zu lösen. Eine Anpassung der unterschiedlichen Impedanzen zwischen Bauelement und Messapparatur ist unbedingt notwendig, um Reflexionen bei der Übertragung zu vermeiden und somit die Gewinnoptimierung zu erhöhen. Zur Behebung der Fehlanpassung wurde im Rahmen dieser Arbeit ein Impedanz-Anpassungs-Netzwerk auf einer PCB-Platine realisiert, welches mit der Probe verbunden wurde. Die Anpassung wurde durch eingebaute Strichleitungen in das Layout des Anpassungsboards vorgenommen. Durchgeführte Simulationen der Probe in Verbindung mit dem Anpassungs-Netzwerk bestätigten die experimentellen Ergebnisse. Durch die Anpassung konnte der simulierte Reflexionskoeffizient deutlich reduziert werden, bei gleichzeitiger Erhöhung des Transmissionskoeffizienten. Ebenfalls zeigten die Messungen an einer Drei-Kontakt-Struktur mit Anpassungs-Board eine signifikante Verbesserung der Leistungsverstärkung. N2 - Dynamical Charging and Discharging of laterally aligned quantum dot structures We can demonstrate that the direct positioning enables us to embed quantum dots with given periods to each other of only a few 100 nm and therefore with a defined density into the memory-structures. For low temperatures, well defined Coulombblockade can be observed. The analysis of the measured diamond patterns allows the determination of the dimension and the charging energy of the embedded quantum dots in the channel. The memory properties of these quantum dots were analyzed and discussed in terms of the hysteresis width DeltaVth which depends on the channel width, the applied drain voltage and the device temperature. The measurements reveal a dependence of the threshold voltage on the channel width of the structure. For devices with a wide channel the current transport sets in with negative applied gate voltages, in contrast to structures with narrow channels, requiring positive gate voltages to cause a current flow through the channel. To explain these results we assume that in large channels a higher negative voltage is necessary to deplete the charges out of the channel due to the higher charge density. To analyze the temperature stability of the charge states the threshold voltage as well as the hysteresis width is detected as a function of the temperature for different drain voltages in the range of 4.2K up to room temperature. It is determined that the hysteresis width decreases to a critical temperature before it rises again. For the investigation of the threshold voltage a difference between Vth,up and Vth,down is demonstrated. We assume that this difference is caused by the different charging behavior for increasing charge energies. In this work, lateral and vertical positioned InAs quantum dots could be demonstrated as a memory device operated at room temperature for the first time. Improved transistor functionality caused by gate leakage currents in nanoscaled Three Terminal Structures Further we investigate the role of gate leakage on the drain current in a monolithic, unipolar GaAs/AlGaAs heterostructure based on three leaky coupled contacts. Two in-plane barriers, defined by rows of etched holes in a two-dimensional electron gas, separate the leaky gate from the central drain and the drain from the source. Because of this the internal resistance of the structure can be appreciably decreased. It should be noted that the observed differential voltage amplification in the gate leakage regime of the studied structure is by far larger compared to the voltage amplification of any in-plane wire transistor fabricated from the same wafer, which were controlled by two non-leaking in-plane gates. The calculated transconductance increases quadratically and not in a non-linear manner, as expected. A pronounced reduction of the drain current sets in when the gate starts to leak, pointing at a large parallel gate capacitor. We associate the gate-leakage current induced gating with a virtual floating gate induced by the space charge injected from the gate. The space charge can hereby be described by a parallel gate capacitor that can control a low dimensional channel lying nearby. High frequency measurements on Three Terminal Structures High frequency measurements for determination of the power gain in Three Terminal Structures are carried out at room temperature. To improve the high frequency properties of the investigated structures a special design was chosen, where the gold contacts for contacting the sample approach very closely the active switching region. The measurements show that negative gate voltages are much more efficient to the power gain than positive ones. For these voltage combinations a power gain > 1 dB for frequencies in the GHz range is detected, whereas the power gain saturates for higher voltages. This is interpreted in terms of the maximum number of charges in the active region between the gold contacts. Furthermore an answer to the fundamental obstacle of the impedance mismatch for high frequency measurements on nanoelectronic structures with high internal resistance is given. Such a matching between the device and the measurement setup is necessary to reduce signal reflections and therefore increase the gain. To match the impedances, an impedancematching- network on a PCB-plate (printed circuit board) via integrated stubs was realized. Simulation data of the sample in connection with the matching-network is in very good agreement with the experimental data. Using the network reduces the simulated reflection coefficient and simultaneously raises the transmission coefficient. The measurements also show a significant improvement of the power gain behaviour. KW - Verstärkung KW - Hochfrequenz KW - Nanoelektronik KW - HEMT KW - Quantenpunkt KW - Coulomb-Blockade KW - Leistungsverstärkung KW - power gain Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-37589 ER - TY - THES A1 - Sochor, Benedikt T1 - Aggregation behavior of Pluronic P123 in bulk solution and under confinement at elevated temperatures near its cloud point T1 - Aggregationsverhalten von Pluronic P123 in Lösung und an Grenzflächen bei hohen Temperaturen nahe des Trübungspunktes N2 - This thesis aims to investigate the form-phase diagram of aqueous solutions of the triblock copolymer Pluronic P123 focusing on its high-temperature phases. P123 is based on polyethylene as well as polypropylene oxide blocks and shows a variety of di erent temperaturedependent micelle morphologies or even lyotropic liquid crystal phases in aqueous solutions. Besides the already well-studied spherical aggregates at intermediate temperatures, the size and internal structure of both worm-like and lamellar micelles, which appear near the cloud point, is determined using light, neutron and X-ray scattering. By combining the results of time-resolved dynamic light as well as small-angle neutron and X-ray scattering experiments, the underlying structural changes and kinetics of the sphere-to-worm transition were studied supporting the random fusion process, which is proposed in literature. For temperatures near the cloud point, it was observed that aqueous P123 solutions below the critical crystallization concentration gelate after several hours, which is linked to the presence and structure of polymeric surface layers on the sample container walls as shown by neutron re ectometry measurements. Using a hierarchical model for the lamellar micelles including their periodicity as well as domain and overall size, it is possible to unify the existing results in literature and propose a direct connection between the near-surface and bulk properties of P123 solutions at temperatures near the cloud point. N2 - Ziel dieser Dissertation ist die Untersuchung des Form-Phasendiagrams des Dreiblock-Co- polymers Pluronic P123 mit dem besonderen Fokus auf dessen Phasenverhalten bei hohen Temperaturen. P123 besteht aus Polyethylen- und Polypropylenoxid-Blöcken und zeigt in wässriger Lösung vielfältige, temperaturabhängige Mizellformen oder sogar Flüssigkristallphasen. Neben den bereits intensiv untersuchten sphärischen Aggregaten bei mittleren Temperaturen, werden die Größen und inneren Strukturen der wurmartigen und lamellearen Aggregate mittels Licht-, Neutronen- und Röntgenstreumethoden untersucht, welche nahe des Trübungspunktes der Lösungen auftreten. Durch die Kombination von zeitaufgelösten dynamischen Licht- und Kleinwinkelstreuung-Experimenten wurden die strukturellen Änderungen und kinetischen Prozesse während des Kugel-Wurm-Übergangs untersucht, welche den bereits in der Literatur vorgeschlagenen zufälligen Fusionsprozess weiter bestätigen. Es wurde beobachtet, dass wässrige P123-Lösungen unterhalb der kritischen Kristallisationskonzentration nach mehreren Stunden gelieren, was durch Neutronenreflektometrie mit dem Auftreten und der Struktur von oberflächennahen Monolagen auf den Messzellwänden in Verbindung gebracht wurde. Wenn ein hierarchisches Model für die lamellaren Mizellen verwendet wird, das deren Periodizität, Domänen- und Gesamtgröße berücksichtigt, ist es außerdem möglich, die bisherigen Ergebnisse in der Literatur zu vereinigen und eine direkte Verbindung zwischen dem Aggregationsverhalten von P123 auf Oberflächen und in Lösung bei Temperaturen nahe des Trübungspunktes zu ziehen. KW - Weiche Materie KW - Polymerlösung KW - Micelle KW - Röntgenstreuung KW - Neutronenstreuung KW - Soft matter KW - worm-like micelles KW - lamellar micelles KW - neutron reflectometry KW - SAXS KW - SANS KW - DLS KW - Pluronic KW - P123 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-246070 ER - TY - THES A1 - Slobodskyy, Taras T1 - Semimagnetic heterostructures for spintronics T1 - Semimagnetische Heterostrukturen für Spintronik N2 - Für zukünftige Technologien ist die Erforschung von der verwendeten Teilchen nötig. Spintronik ist ein modernes Gebiet der Physik, welches neben der Ladung auch die Spineigenschaften als zus¨atzlichen Freiheitsgrad nutzbar macht. Der ”conductivity mismatch” stellt ein fundamentales Problem für elektrische Spininjektion aus einem ferromagnetischem Metal in einen diffusiven Halbleiter dar. Daher müssen andere Methoden für die Injektion spin-polarisierter Ladungsträger benutzt werden. Mit einem Tunnelkontakt ist es möglich, eine hoch spin-polarisierte, Raumtemperatur Tunnel-Injektion zu erzielen. Wir benutzten einen neuen Ansatz und verwendeten magnetische RTDs zur Spinmanipulation. In dieser Arbeit wurden die Eigenschaften von magnetischen, resonanten Tunneldioden (RTDs) aus rheinen II-VI-Halbleitern in ihrer Verwendung für die Spintronik beschrieben. Wachstumsbedingungen wurden optimiert, um das Peak-to-Valley-Verhältnis zu vergrößern. Das Design der RTDs wurde optimiert, um spinbezogene Transporteffekte beobachten zu könen. Mit einem externen Magnetfeld war Spinmanipulation möglich. Selbstorganisierte CdSe Quanten-Strukturen wurden hergestelt und mit optischen Techniken untersucht. Sie würden in (Zn,Be)Se Tunnelbarrieren eingebettet, so dass ihre Eigenschaften durch resonantes Tunneln zugänglich wurden. N2 - In pursuit of a novel generation of devices, exploration of spin properties of the particles is needed. Spintronics is a modern field in physics which exploits spin properties to be used in addition to the charge degree of freedom. Since the conductivity mismatch problem presents a fundamental obstacle for electrical spin injection from a ferromagnetic metal into a diffusive semiconductor [SFM+00], other means for injecting spin-polarized carriers must be used. With a tunnel contact, it is possible to achieve a highly spin-polarized room-temperature tunnel injection [JWS+05]. We used a novel approach and applied magnetic RTDs for spin manipulation. In this work, properties of all-II-VI magnetic resonant tunneling diodes (RTDs), as applied to spintronics, were reported. Growth conditions were optimized to increase the peak-to-valley ratio, and the design of the RTDs was optimized for observation of spin related transport effects. When an external magnetic field was applied, spin manipulation became possible. Selforganized CdSe quantum structures were grown and investigated using optical means. After embedding them into a (Zn,Be)Se tunneling barrier, the properties were assessed by the resonant tunneling. KW - Heterostruktur-Bauelement KW - Semimagnetischer Halbleiter KW - Magnetoelektronik KW - Halbleiter KW - Spintronik KW - ZnMnSe KW - Semiconductors KW - Spintronics KW - ZnMnSe Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-21011 ER - TY - THES A1 - Slobodskyy, Anatoliy T1 - Diluted magnetic semiconductor Resonant Tunneling Structures for spin manipulation T1 - Verdünnt magnetische Halbleiter Resonante Tunnel-Strukturen für Spin Manipulation N2 - In this work we investigate magnetic resonant tunneling diode (RTD) structures for spin manipulation. All-II-VI semiconductor RTD structures based on [Zn,Be]Se are grown by molecular beam epitaxy. We observe a strong, magnetic field induced, splitting of the resonance peaks in the I-V characteristics of RTDs with [Zn,Mn]Se diluted magnetic semiconductors (DMS) quantum well. The splitting saturates at high fields and has strong temperature dependence. A phonon replica of the resonance is also observed and has similar behaviour to the peak. We develop a model based on the giant Zeeman splitting of the spin levels in the DMS quantum well in order to explain the magnetic field induced behaviour of the resonance. N2 - In dieser Arbeit werden magnetische resonante Tunneldioden (RTD) hinsichtlich ihrer Eignung zur Spin-Manipulation untersucht. [Zn, Be]Se basierende II-VI RTD-Strukturen wurden mittels Molekularstrahlepitaxie gewachsen. Man beobachtet eine starke, vom Magnetfeld induzierte Aufspaltung der Resonanz in der U-I Kennlinie derjenigen RTDs, die über einen Quantentrog aus [Zn, Mn]Se verdünnt magnetischen Halbleiter (DMS) verfügen. Diese Aufspaltung hat eine starke Temperaturabhängigkeit und erreicht bei hohen Feldern eine Sättigung. Eine Phononen-Replika der Resonanz wird ebenfalls beobachtet und hat ähnliche Eigenschaften wie die Resonanz selbst. Es wird ein Modell entwickelt, welches auf der Giant-Zeeman-Aufspaltung der Spin-Aufgespalteten Niveaus des DMS-Quantentrogs basiert, um das magnetfeldabhängige Verhalten der Resonanz zu erklären. KW - Resonanz-Tunneldiode KW - Semimagnetischer Halbleiter KW - Magnetoelektronik KW - spintronik KW - spin Injektion KW - verdünnt magnetische Halbleiter KW - resonante Tunneldioden KW - spintronics KW - spin injection KW - diluted magnetic semiconductors KW - resonant tunneling diode Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-18263 ER - TY - THES A1 - Simin, Dmitrij T1 - Quantum Sensing with Highly Coherent Spin Centers in Silicon Carbide T1 - Quantensensorik mit hochkohärenten Spinzentren in Siliciumcarbid N2 - In the present work, the energetic structure and coherence properties of the silicon vacancy point defect in the technologically important material silicon carbide are extensively studied by the optically detected magnetic resonance (ODMR) technique in order to verify its high potential for various quantum applications. In the spin vacancy, unique attributes are arising from the C3v symmetry and the spin-3/2 state, which are not fully described by the standard Hamiltonian of the uniaxial model. Therefore, an advanced Hamiltonian, describing well the appearing phenomena is established and the relevant parameters are experimentally determined. Utilizing these new accomplishments, several quantum metrology techniques are proposed. First, a vector magnetometry scheme, utilizing the appearance of four ODMR lines, allows for simultaneous detection of the magnetic field strength and the tilting angle of the magnetic field from the symmetry axis of the crystal. The second magnetometry protocol utilizes the appearance of energetic level anticrossings (LAC) in the ground state (GS) energy levels. Relying only on the change in photoluminescence in the vicinity of this GSLACs, this all-optical method does not require any radio waves and hence provides a much easier operation with less error sources as for the common magnetometry schemes utilizing quantum points. A similar all-optical method is applied for temperature sensing, utilizing the thermal shift of the zero field splitting and consequently the anticrossing in the excited state (ES). Since the GSLACs show no dependence on temperature, the all-optical magnetometry and thermometry (utilizing the ESLACs) can be conducted subsequently on the same defect. In order to quantify the achievable sensitivity of quantum metrology, as well as to prove the potential of the Si-vacancy in SiC for quantum processing, the coherence properties are investigated by the pulsed ODMR technique. The spin-lattice relaxation time T1 and the spin-spin relaxation time T2 are thoroughly analyzed for their dependence on the external magnetic field and temperature. For actual sensing implementations, it is crucial to obtain the best signal-to-noise ratio without loss in coherence time. Therefore, the irradiation process, by which the defects are created in the crystal, plays a decisive role in the device performance. In the present work, samples irradiated with electrons or neutrons with different fluences and energies, producing different defect densities, are analyzed in regard to their T1 and T2 times at room temperature. Last but not least, a scheme to substantially prolong the T2 coherence time by locking the spin polarization with the dynamic decoupling Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence is applied. N2 - In der vorliegenden Arbeit werden die energetische Struktur und die Kohärenzeigenschaften der Silizium Fehlstelle in dem technologisch relevanten Material Siliciumcarbid mit Hilfe der optisch detektierten Magnetresonanz (ODMR) Technik extensiv analysiert, um ihr außerordentliches Potential für verschiedene quanten-mechanische Anwendungen zu untermauern. Aus der C3v Symmetrie und dem 3/2 Spinsystem des Defekts entstehen einzigartige Attribute, die nur teilweise durch den Standard Hamiltonoperator des Modells einer einachsigen Symmetrie wahrheitsgemäß beschrieben werden. Aus diesem Grund wird ein weiterentwickelter Hamiltonoperator aufgestellt, welcher die auftretenden Eigenschaften genau wiedergibt. Aus experimentellen Messungen werden anschließend seine Parameter bestimmt. Das nun vorliegende genaue Verständnis der auftretenden Phänomene wird dazu genutzt, diverse Methoden zur Quantensensorik auszuarbeiten. Zuerst wird ein Schema für Vektormagnetometrie aufgestellt, welches sich das Auftreten von vier ODMR Linien zunutze macht. Die Methode ermöglicht simultane Detektion, sowohl von der Magnetfeldstärke, als auch von dem Winkel zwischen der Magnetfeldrichtung und der Symmetrieachse des Kristalls. Das zweite Magnetometrie protokoll nutzt das Auftreten von energetischen anticrossings (level anticrossing, LAC) im Grundzustand (ground state, GS). Durch das Verfolgen der Änderung der Photolumineszenz in der Nähe dieser GSLACs, braucht diese rein optische Technik keine Radiowellen und ist dementsprechend viel leichter umzusetzen und bietet weniger Fehlerquellen als die üblichen Magnetometriemethoden an Quantenpunkten. Eine ähnliche, rein optische Methode wird auch für Temperaturmessungen vorgestellt, welche auf der thermisch induzierten Verschiebung der Nullfeldaufspaltung und somit auch der anticrossings im angeregten Zustand (excited state, ES) basiert. Da die GSLACS keine Temperaturabhängigkeit zeigen, können die rein optischen Methoden zur Magnetfeld- und Temperaturmessung nacheinander am selben Defekt erfolgen. Um die erreichbare Sensitivität der Quantenmetrologie zu quantifizieren und auch um das Potential der Si-Vakanzen für Quantencomputing zu demonstrieren, werden die Kohärenzeigenschaften mit Hilfe der gepulsten ODMR Technik analysiert. So werden die Spin-Gitter Relaxationszeit T1 und die Spin-Spin Relaxationszeit T2 eingehend analysiert und deren Abhängigkeit von einem externen Magnetfeld und der Temperatur aufgestellt. Für tatsächliche Implementierung in einem Sensor, ist es entscheidend ein Optimum zwischen dem Signal-Rausch-Verhältnis und der Kohärenzlänge zu etablieren. Deswegen spielt die Kristallbestrahlung, durch die die Defekte erzeugt werden, eine wichtige Rolle für die Leistungsfähigkeit des Endgerätes. In der vorliegenden Arbeit werden unterschiedlich bestrahlte Proben, nämlich einmal mit Elektronen und einmal mit Neutronen unterschiedlicher Energie und mit unterschiedlichen Bestrahlungsdosen, analysiert. Anschließend wird eine Methode zur substantiellen Verlängerung der T2 Kohärenzzeit durch das locking der Spinpolarisation mit der Carr-Purcell-Meiboom-Gill (CPMG) Pulssequenz durchgeführt. KW - Siliciumcarbid KW - ODMR-Spektroskopie KW - Gitterbaufehler KW - silicon vacancy KW - pulsed ODMR KW - quantum metrology KW - quantum sensing KW - Siliciumvakanz KW - Silicium Fehlstelle KW - Quantensensorik KW - Feldstärkemessung Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-156199 ER - TY - THES A1 - Sidiropoulou, Ourania T1 - Characterization of the ATLAS-type Micromegas Detectors T1 - Charakterisierung von Micromegas-Detektoren des ATLAS-Typs N2 - Micromegas are parallel-plate gaseous detectors with micro-pattern readout structures that are able to measure precisely and efficiently at high particle rates. Their difference with respect to other gaseous detectors is that the space in which particles ionise the gas and create electrons is separated from the region in which these electrons are multiplied (or amplified) by a thin metallic mesh. In the ionisation region, typically a few mm thick, a moderate field of a few hundred V/cm is applied. The amplification region with a homogeneous electrical field of 40--50~kV/cm is only 100--150~$\upmu$m thick. The latter guarantees that the positive ions produced in the amplification process are rapidly evacuated and the possibility to build up space charge at high rate is reduced. Critical in micromegas detectors are sparks in the thin amplification region in the presence of the high electrical field. This problem was solved in 2011 by introducing a spark protection scheme. It consists of a layer of resistive strips on top of the readout strips, separated from the latter by a thin insulation layer. Micromegas with the spark protection scheme were selected as instrumentation of the first ATLAS forward muon station (NSW) in the upgrade of the ATLAS detector for the operation of the Large Hadron Collider (LHC) at high luminosity (HL-LHC), expected for 2026. The main subjects of this thesis are: the characterisation of the first micromegas quadruplet prototypes for the NSW detectors; the characterisation of the materials used in the spark-protection system; and the study of the influence of the mesh distance holders (pillars) on the detector performance. The thesis starts with a brief introduction into the LHC and ATLAS projects, followed by a chapter that explains the reason for the upgrade of the ATLAS muon system and shows the layout of the NSW. The first of the three main chapters covers the construction and the characterisation of the first two prototypes for the NSW detectors. These detectors comprise four detection layers and have the same mechanical structure as the NSW detectors. The mechanical precision as well as the homogeneity of the detector response are discussed. The latter has been measured using X-rays and cosmic rays. The spatial resolution that can be achieved with these detectors precision has been measured at the MAMI accelerator at Mainz with low-energy electrons. The chapter is completed by a section that describes the successful integration of a data acquisition system (DAQ) into the official ATLAS DAQ system that was required for an initially planned installation of one of the prototypes on the existing Small Wheel. The next chapter presents a study of the influence of temperature and humidity changes on the resistive strips used in the spark protection system. In addition the long-term stability of the resistive material has been measured accumulating charge equivalent to 100 years of operation in the HL-LHC and exposing the samples to intense gamma irradiation equivalent to 10 years of HL-LHC operation. The third part covers the impact of the mesh distance holders (pillars) on the performance of the detector. This study has been performed with a 10 x 10 cm$^2$ bulk-micromegas with two different pillar shapes. Both 5.9 keV gammas from a $^{55}$Fe and 8 keV X-rays from a Cu target were used. In this context also the electrostatic charge-up of the detector is discussed. In the Appendices one finds a summary of the fundamental physics relevant for gaseous detectors as well as some supporting material for the topics covered in the main part of the thesis. N2 - Micromegas-Detektoren sind Gas-Detektoren aus der Familie der Parallel-Platten-Detektoren mit sehr feinen Auslese-Elementen, die präzise und effizient bei hohen Teilchenraten messen können. Sie unterscheiden sich von anderen Gas-Detektoren dadurch, dass der Bereich, in dem die zu messenden Teilchen das Gas ionisieren und damit Elektronen produzieren, von dem Bereich, in dem diese Elektronen vervielfältigt werden, durch ein feines metallisches Gitter getrennt ist. Im Ionisationsbereich der gewöhnlich mehrere mm dick ist, wird ein moderates elektrisches Feld von einigen hundert Volt angelegt. Der Vervielfachungs- oder Verstärkungsbereich mit einem homogenen elektrischen Feld von $\sim$40--50 kV/cm ist nur 100--150 $\upmu$m dick. Dadurch können die positiven Ionen, die im Vervielfältigungsprozess entstehen, schnell abgeleitet werden und der Aufbau von Raumladung bei hohen Teilchenraten wird begrenzt. Ein kritisches Element der Micromegas Detektoren sind spontane Entladungen in dem starken elektrischen Feld und dem sehr dünnen Verstärkungsbereich. Diese Problem wurde 2011 durch die Einführung einer Schutzschicht gelöst. Diese besteht aus einer dünnen Isolationsschicht über den Auslesestreifen, auf die Widerstandsstreifen aufgebracht werden. Micromegas-Detektoren mit Widerstandsschutz wurden für die Instrumentierung der ersten Station des ATLAS Myon-Systems in Vorwärtsrichtung (NSW) als Mess- und Auslöse-Instrumente für den Betrieb des Large Hadron Colliders (LHC) bei höherer Luminosität (HL-LHC, ab 2020) gewählt. Das Ziel dieser Arbeit ist: 1. die Messung der Eigenschaften der ersten Micromegas NSW Prototypen; 2. die Untersuchung der Eigenschaften des Materials, das für die Widerstandsstreifen benutzt wird; und 3. die Bestimmung des Einflusses der Gitter-Abstandshalter (pillars) auf die Eigenschaften des Detektors. Die Arbeit beginnt mit einer kurzen Einführung, die den LHC und das ATLAS Projekt vorstellt, gefolgt von einem Kapitel, das erklärt, warum die jetzt installierten Myon-Detektoren ersetzt werden müssen, um bei einer konsequenten Erhöhung der LHC-Luminosität nicht an Messgenauigkeit zu verlieren. Es zeigt dann wie die neue Myon Station, das New Small Wheel (NSW), aussehen wird. Im ersten der Hauptkapitel werden der Bau und die Untersuchung der ersten beiden Prototypen für die NSW Detektoren beschrieben. Diese Detektoren (MMSW) bestehen aus vier Messlagen und haben die gleiche mechanische Struktur wie die NSW Detektoren. Sowohl die mechanische Präzision als auch die Homogenität der Signale über den gesamten Detektor und die Teilchen-Nachweiswahrscheinlichkeit werden diskutiert. Letztere wurden mit Röntgenstrahlen und Teilchen aus der kosmischen Strahlung gemessen. Die Ortsauflösung wurde am MAMI Beschleuniger in Mainz mit nieder energetischen Elektronen gemessen. Das Kapitel wird komplettiert durch einen Abschnitt, der die erfolgreiche Integration eines Datenerfassungssystems für die MMSW Detektoren in das offizielle ATLAS Datenerfassungssystem beschreibt. Solch ein System wurde für die ursprünglich geplante Installation eines der MMSW Detektoren in ATLAS gebraucht. Danach wird die Untersuchung der Eigenschaften der Widerstandsstreifen präsentiert, insbesondere deren Abhängigkeit von Temperatur und relativer Luftfeuchtigkeit, sowie ihr Langzeitverhalten. Dafür wurden die Streifen einem Stromfluss ausgesetzt der 100 Jahren Betrieb im LHC entspricht, zum anderen einer Gamma Strahlendosis ausgesetzt, wie sie bei einem 10-jährigen LHC Betrieb erwartet wird. Im dritten Teil folgt eine ausführliche Studie des Einflusses der Gitter-Abstands-halter (pillars) auf die Ortsauflösung und die Nachweiswahrscheinlichkeit. Diese Studie wurde mit einem 10 $\times$ 10 cm$^2$ großen Micromegas Detektor mit zwei verschiedenen Abstandshalterformen sowohl mit 5.9 keV Gamma-Strahlen von einer $^{55}$Fe Quelle, als auch mit 8 keV Photonen aus einer Röntgen-Quelle durchgeführt. In diesem Zusammenhang wird auch die elektrostatische Aufladung des Detektors diskutiert. Im Anhang findet sich eine Zusammenfassung der physikalischen Grundlagen, die für Gasdetektoren relevant sind, sowie zusätzliches Material zu den oben beschriebenen Kapiteln. KW - micromegas detectors KW - ATLAS New Small Wheels (NSW) KW - resistive micromegas KW - micro pattern gaseous detectors KW - muon spectrometer KW - ATLAS KW - Gasionisationsdetektor Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-167323 ER - TY - THES A1 - Shuvaev, Alexey T1 - Spectroscopic study of manganites with magnetoelectric coupling T1 - Spektroskopische Untersuchungen an Manganoxyd-verbindungen mit magnetoelektrischer Kopplung N2 - The present thesis is devoted to the spectroscopic study of rare earth manganites RMnO3 (R = Gd, Dy, Tb, Eu(1 - x)Y(x)) in the submillimeter frequency range. A dynamic manifestation of a strong magnetoelectric coupling in these systems is the existence of electromagnons - spin waves excited by the electric component of the electromagnetic wave. The exact analytical solution of the Landau-Lifshitz equations obtained for cycloidal antiferromagnets builds the bridge between the inelastic neutron scattering and the optical experiments. A semi-quantitative agreement is achieved between the theory and the results by these two experimental techniques. Two suggested mechanisms of the magnetoelectric coupling, the inverse Dzyaloshinskii-Moriya (IDM) interaction and the symmetric Heisenberg exchange (HE) striction, are introduced in a perturbative manner. The qualitative conclusions regarding both static and dynamic electric properties are also in agreement with the experiment. GdMnO3 is the system in which the electromagnons were first detected at low frequencies. Far infrared measurements in GdMnO3 presented here have confirmed the existence of a second high frequency electromagnon at 75 reciprocal centimeter. The detection of an additional mode suggests the existence of at least short range ferroelectric order. Such order has not been observed in static experiments so far. The electromagnons in Eu(1 - x)Y(x)MnO3 helped to clarify the role of the rare earth magnetism. As the Y(3+) ions are diamagnetic and Eu(3+) ions possess Van Vleck paramagnetism only, it is the Mn subsystem that is primarily responsible for the magnetoelectric properties of rare earth manganites. The electromagnons in DyMnO3 and TbMnO3 do not change their excitation conditions upon the flop of the spin cycloid in external magnetic fields. This fact still lacks consistent theoretical explanation. Detailed measurements on TbMnO3 of different orientations have allowed to prove the existence of the IDM electromagnon. The study of DyMnO3 in external magnetic fields has shown that, depending on the Dy ordering, the electromagnons and static electric polarization can be either enhanced or suppressed. Thus, the magnetic order of rare earth moments still plays an important role. As a general result of the present work, the IDM interaction is capable to describe the static electric polarization and the weak electro-active excitation in the high-field phase of TbMnO3. The HE model is successful in explaining the high frequency electromagnon, including its excitation conditions and the spectral weight. However, both models are still unable to describe the energy and the spectral weight of the low frequency electromagnon. Further theoretical and experimental efforts are required in this direction. N2 - Die vorliegende Dissertation befasst sich mit den spektroskopischen Untersuchungen von Manganaten der Seltenen Erden im Bereich der Submillimeterwellen. Spektroskopisches Merkmal der starken elektromagnetischen Kopplung ist die Existenz der Elektromagnonen - Spinwellen, die durch das elektrische Feld des Lichtes angeregt werden. Die Lösung der Landau-Lifshitz Gleichungen für die zykloidale magnetische Ordnung verbindet die inelastische Neutronstreuung mit den optischen Experimenten. Eine halbquantitative Übereinstimmung wurde zwischen der Theorie und diesen zwei experimentellen Techniken erreicht. Zwei Mechanismen der magnetoelektrischen Kopplung, die inverse Dzyaloshinskii-Moriya (IDM) Wechselwirkung und das auf den symmetrischen Heisenberg Austausch basierte Modell, werden in einer perturbativen Art eingefürt. Die Ferninfrarotmessungen an GdMnO3 zeigen die Existenz eines zweiten Elektromagnons bei 75 Reziprokzentimeter. Diese Beobachtung deutet auf die Existenz von zumindest kurzweitigen ferroelektrischen Ordnungsparameter in GdMnO3. Die Untersuchung der Elektromagnonen in Eu(1 - x)Y(x)MnO3 Mischsystemen hat die Rolle des Magnetismus der Seltenen Erden geklärt. Nachdem Y(3+) Ionen diamagnetisch sind und Eu(3+) Ionen nur Van Vleck Paramagnetismus aufweisen, ist das Mn Untersystem vorrangig für die magnetoelektrischen Eigenschaften der Selten-Erd-Manganaten verantwortlich. Die Untersuchung von DyMnO3 in äußeren Magnetfeldern hat gezeigt, dass, je nach magnetischer Ordnung von Dy, die Elektromagnonen und die statische elektrische Polarization entweder erhöht oder unterdrückt werden können. Daher spielt die magnetische Ordnung der Seltenen Erde eine wichtige Rolle. Nach der Rotation der Spinzykloide in äußeren Magnetfeldern ändern die Elektromagnonen in DyMnO3 und TbMnO3 ihre Auswahlregeln nicht. Für diese Beobachtung fehlt jedoch noch eine übereinstimmende theoretische Erklärung. Die genauen Messungen von unterschiedlich orientierten TbMnO3 Proben ermöglichten einen schwachen elektrischen Beitrag bei 21 Reziprokzentimeter zu detektieren. Das ist die erste direkte Beobachtung einer dynamischen Anregung der IDM Wechselwirkung. Zusammenfassend, kann die IDM Wechselwirkung die statische elektrische Polarization und die schwache elektrische Anregung in der Hochfeldphase von TbMnO3 gut beschreiben. Das HE Modell wird erfolgreich bei der Erklärung des Hochfrequenzelektromagnons, dessen Auswahlregeln und des Spektralgewichts angewandt. Beide Modelle sind jedoch noch nicht in der Lage die Energie und das Spektralgewicht des Niederfrequenzelektromagnons zu beschreiben. Weitere theoretische Anstrengungen sind nötig um die noch verbleibenden offenen Fragen zu klären. KW - Manganverbindungen KW - Seltenerdverbindungen KW - FIR-Spektroskopie KW - Terahertz KW - Elektromagnon KW - Seltene Erden KW - Inkommensurable Zykloide KW - Magnetoelektrischer Effekt KW - Terahertz spectroscopy KW - Rare earth manganites KW - Electromagnon KW - Magnetoelectric effect KW - Incommensurate spin structure KW - Spektroskopie KW - Multiferroikum KW - Manganate KW - Dielektrikum KW - Magnon Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-78719 ER - TY - THES A1 - Seufert, Mirjam T1 - Herstellung und Charakterisierung von abstimmbaren und Hochleistungslasern auf GaSb T1 - Fabrication and Characterisation of Widely Tunable and High Power Laser based on GaSb N2 - Ziel dieser Arbeit war es, basierend auf dem AlGaIn-AsSb Materialsystem neuartige Laserbauelemente mit bisher unerreichten Kenndaten zu entwerfen, herzustellen und zu untersuchen. Der Fokus lag dabei zum Einen auf einer Steigerung der optischen Ausgangsleistung in Kombination mit einem monomodigen spektralen Emissionsverhalten. Zum anderen lag ein wesentliches Hauptaugenmerk auf der Realisierung von monomodig emittierenden Lasern mit einem weiten Wellenlaengenabstimmbereich. N2 - The goal of this work was to design, realize and characterize innovative laser devices based on the AlGaIn-AsSb material system with previously un-reached characteristic device performance. The focus was on the one hand on the enhancement of the optical output power in combination with a singlemode spectral emission behavior. On the other hand the essential task throughout this work was the realization of singlemode emitting lasers with a broad wavelength tuning range. KW - Abstimmbarer Laser KW - Hochleistungslaser KW - Galliumantimonid KW - Gallium KW - Halbleiterlaser KW - widely tunable laser KW - semiconductor laser KW - high power laser KW - gasb Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-52122 ER - TY - THES A1 - Seres, Enikõ T1 - Ultraschnelle zeitaufgelöste Absorptionsspektroskopie im weichen Röntgenbereich T1 - Ultrafast timeresolved absorptionspectroscopy in soft X-ray regime N2 - Bis in die 50er Jahren wurden ausschließliche Röntgenröhren in der Röntgenspektroskopie benutzt. (Parratt, 1938). In den 50er Jahren wurden die ersten Synchrotrons gebaut und für die Spektroskopie im Röntgenbereich angewendet. (Blocker et al., 1950). Die auch noch heute verwendeten Techniken wurden zum ersten Mal 1948 (Elder et al. 1948) in der Literatur beschrieben. Doch es dauerte Jahrzehnte, bis mit den neu zur Verfügung stehenden Synchrotrons die statische Röngendiffraktometrie zur röntgenspektroskopischen Strukturaufklärung routinemäßig benutzt werden konnte. Diese Entwicklungen werden bis heute fortgeführt und ebneten den Weg für viele Anwendungen. Während dieser Zeit ist auch ein anderer Wissenschaftszweig entstanden, die Lasertechnik. Diese ist seit dieser Zeit auch enorm gewachsen, und jetzt fordert sie auch die Synchrotrons bei der zeitaufgelösten Röntgenspektroskopie heraus. Die Laserstrahlung war am Anfang kontinuierlich. Erst durch die späteren Entwicklungen konnte ein gepulster Betrieb realisiert werden. Mit der Zeit wurden die Laserpulse immer kürzer und die Pulsenergie ist immer mehr gewachsen. Die kurze Pulsdauer der Laser wird in so genannten Pump-Probe Messungen verwendet: damit können schnelle Änderungen, die von einem Pumppuls ausgelöst werden mit einem Probepuls verfolgt werden. Die Auflösung der Messung ist durch die Pulsdauer gegeben. Die Pulsdauer wurde in den letzten Jahrzehnten vom Nanosekunden- bis in den Femtosekundenbereich reduziert. Hier ergibt sich aber nicht etwa eine technologische Grenze sondern eine fundamentale. Die zurzeit kürzesten Laserpulse haben eine Dauer von einigen wenigen Femtosekunden und sind damit schon sehr nahe der Periodendauer einer optischen Schwingung, die ebenfalls 1 bis 2fs beträgt. Allerdings zeigt sich auch, dass mit den zur Verfügung stehenden Laserpulsen die Zeitauflösung ausreicht um fast alle Vorgängen zu beobachten. Nur ist die Interpretation manchmal sehr schwierig, wenn es gilt das gemessene Signal einer atomaren Bewegung zuzuordnen. Abhilfe schafft hier die Verwendung von Röntgenstrahlung, die hervorragend geeignet ist Strukturinformation direkt zu erhalten. Wenn die Strahlung gepulst ist kann damit auch die Dynamik der Struktur erfasst werden. Ein Erfolg versprechender Ansatz zur Erzeugung von Röntgenpulsen mit einer Dauer von einigen Femtosekunden ist die Konversion von ultrakurzen Laserpulsen in den Röntgenbereich. Heute dazu erfolgreich demonstrierte Techniken sind die Laser-Plasmaquellen oder die hoher Harmonische Erzeugung (HHG). Die Plasmaquellen erzeugen im keV Energiebereich Röntgenphotonen – aber nur mit einer Pulsdauer von einigen 100fs. HHG ist hingegen eine interessante Alternative, die Pulse mit einer Dauer im Attosekundenbereich erzeugen kann. Allerdings war der Spektralbereich bis vor kurzem auf einige 100eV beschränkt. Eine Ausweitung des Spektrums von HHG Strahlung in den keV Bereich macht die Quelle aber erst wirklich einsetzbar für Messungen an technisch und wissenschaftlich interessanten Systemen. Im Energiebereich des Wasserfensters (ca 300 bis 600eV) können biologische Prozesse mit einer Zeitauflösung im ps-fs Bereich verfolgt werden. Im höheren Energiebereich von ca. 700eV kann man die magnetischen Eigenschaften von Selten-Erdmetallen beobachten. Diese Arbeit ist der Entwicklung einer laserbasierten HH-Quelle und deren Anwendung in der zeitaufgelösten Spektroskopie gewidmet. Es sollte herausgefunden werden, welche Anforderungen werden an das Lasersystem in Bezug auf Pulsparameter gestellt, um damit Spektroskopie in einem Bereich bis zu 1keV zu machen. Auch sollte geklärt werden, welche spektroskopischen Methoden sind möglich und wo liegen ihre Grenzen. In dieser Arbeit wurde sehr viel Neuland betreten, sowohl auf dem Gebiet der Lasertechnik als auch auf der Entwicklung der HH Quelle. Darüber hinaus ist diese Arbeit die erste Arbeit die sich mit Anwendung von HH-Strahlung für zeitaufgelöste Röntgenabsorptionsspektroskopie befasst. Das zweite Kapitel befasst sich mit den Grundlagen der Röntgenspektroskopie. Bei der Wechselwirkung von Röntgenstrahlung mit Materie wird die elektronische Struktur, die Elektronenverteilungen der Atome oder Moleküle verändert: Man kann die Elektronen in das Valenzband oder in das Kontinuum anregen. Die in das Kontinuum anregten Elektronen können gleichzeitig mit den Nachbaratomen wechselwirken, und von diesen rückstreuen. Diese Wechselwirkung wird durch elektronische Struktur, die elektronische Verteilung der Atome und Moleküle beeinflusst. Diese Vorgänge verändern die Röntgenabsorption des Materials. Durch die Messung der Veränderung der Röntgenabsorption kann man auf die atomare Struktur, die atomare Abstände folgern. Diese Messungen wurden bisher mit Synchrotronstrahlung durchgeführt, deren Pulsdauer bisher nicht kürzer als einige ps war, und damit nicht den schnellsten Änderungen folgen konnte. Ein Lasersystem mit höherer Energie und kürzerer Pulsdauern ist der Schlüssel zu hochzeitaufgelösten Experimenten. Die Entwicklung eines solchen Lasersystems ist im dritten Kapitel beschrieben. Erster Teil des Kapitels erklärt die Probleme, die durch den Verstärkungsprozess auftreten. Die spektrale Einengung und der Energieverlust sind immer die am schwierigsten zu lösenden Probleme in einem Verstärkersystem. Wegen der nötigen zeitliche Pulsdehnung und der folgenden Pulskompression erleidet der Puls einen Energieverlust. Die nichtlinearen Effekte verursachen spektrale Einengung im Verstärkerkristall. Um diese Nachteile zu vermeiden dienen die unterschiedlichen Techniken, wie die Verwendung einer gasgefüllten Hohlfaser zur nichtlinearen spektralen Verbreiterung und unterschiedlicher Pulsformungstechniken (akustooptische Modulator, LCD,…). Der verbleibende Teil des Kapitels stellt diese Methoden, ihre Vorteilen und Nachteile dar. Abschließend sind die Erfolge bei der Entwicklung des Lasersystems vorgestellt: Nach allen Optimierungen wurden Pulse mit einer Energie von 3mJ und einer Dauer von 12fs realisiert. Die erste Verwendung des neuen Systems war die Erzeugung hoher Harmonischer mit konventioneller Technik. Diese Technik basiert auf einem Aufbau mit einem Gastarget in das die Laserpulse fokussiert werden. Das vierte Kapitel beschreibt die Theorie und Schwierigkeiten des Erzeugungsprozesses durch die Erklärung der grundlegenden mikroskopischen (Erzeugung) und die makroskopischen Effekte (Ausbreitungseffekte) im Gastarget. Das Problem der niederen Konversionseffizienz im hochenergetischen Bereich kann gelöst werden, wenn die neu entwickelte Technik, die als nichtadiabatische Phasenanpassung schon in der Literatur existiert hat, angewendet wird. Sie beruht auf einer starken Fokussierung von extrem kurzen Pulsen und ermöglicht Erzeugung von Röntgenphotonen mit Energien bis zu 3,5keV. Mit diesen schönen Erfolgen wurden die ersten statischen spektroskopischen Experimente durchgeführt. Die aufgenommenen Spektren zeigen schöne Absorptionskanten bei Titan, Kupfer, und Neon, Platin. Die Auswertungen dieser Spektren zeigen, dass es genügend Photonen bis 1keV gibt und ermöglichen so die Anwendung der so genannten EXAFS Technik. Im fünften Kapitel werden die gemessene Röntgenspektren und die mit der EXAFS Methode ermittelten atomaren Abständen von Silizium, Titan und Kupfer, dargestellt. Dieses Kapitel beschreibt ferner unsere ersten erfolgreichen Experimenten zur zeitaufgelöste Röntgenabsorptionsspektroskopie in der Nähe der Silizium L-Kante bei 100eV. Die Zeitauflösung, die mit Hilfe der Pump-Probe Technik erzielt werden konnte war besser als 20fs. Die Messungen wurden in einem weiten Energie – und Zeitbereichen durchgeführt: im Bereich von 0-100ps und 0-1ps, sowie von ca. 70eV bis 500eV. Die bestimmten Zeitkonstanten, stimmen mit in der Literatur angegebenen Werten für die unterschiedlichen Relaxationsprozessen sehr gut überein. N2 - Until the 50s years, the X-ray tubes were used in the X-ray spectroscopy. The first synchrotrons appeared in the 50s years and it took several tens years, when they were applied for the static X-ray diffractrometry and the X-ray structure analysis became routine technique. These techniques are under development up to now for the broadened application areas. During this time, a new area of the physics appeared as e.g. the laser technique. They developed and bloomed meantime and now they challenge the synchrotrons to make more effort in the X-ray spectroscopy. The laser light was continuum at first, but later the pulse operation spread and the aim become to reach possible shortest pulse. The pulse mode makes possible to use the pump-probe technique. The probe pulse sans and tests the effect of the first-coming pump pulse. The resolution of the measurement is defined by the pulse duration of the pulses. This tented from the nanosecond to the femtosecond timescale. Now the metrology works close to the duration of one optical period. In this area, the scientist is not only by the technological rather by a fundamental border. By the application of the commercial pump-probe technique one can gather dynamic information usually in the IR wavelength scale. Near to the atomic scale, one can observe the structure of the material – and by the application of the X-ray pulses is possible to examine the processes, their development and evolutions deeply in the material, close to the atomic and molecular structure. The available X-ray techniques deliver X-ray pulses: the plasma sources can produce keV pulses in the few hundred fs regime. The slicing technique compressed the pulse duration of the synchrotrons down to few hundred fs also. The High Harmonic Generation (HHG) is the only existing technique for single attosecond pulse generation in the 100 eV regime. The development of the HHG forward to the keV energy opens the way for fast spectroscopic measurements in the water-window with fs pulses. The biology waits for a long time for direct observation of the fast organic processes in the fs regime. The 700 eV reaches the limit of the magnetic earth-metal spectroscopy. This work is devoted to the development and application of a laser based HH Source. The exact parameterisation and optimisation of the laser system is inevitable for the keV spectroscopy. It is clarified, which methods are acceptable and which works at their edges. This work describes the development of a laser system, which - application as an X-ray source - reached and overstepped the keV regime. This is the first work, which is devoted to the application of the HH radiation for time resolved absorption spectroscopy. The second chapter describes the bases of the X-ray spectroscopy. The interaction of the X-ray and material changes the electronic structure, the electron distribution of the atoms or molecules: the electrons can be excited from the valence band into the conduction band. The electrons, which are excited in the continuum, can interact with the neighbour atoms, from when they can backscatter. This interaction is affected by the electronic structure and the electronic distribution of the atom and molecules. The processes change the X-ray absorption of the materials. Through the measurements of these modifications can conclude to the atomic structure and atomic distances. Up top now were made these measurements with synchrotron radiation, which pulse duration was not shorter as ps. Therefore they could not observe the faster modifications. These experiments demand a laser system with high energy and short laser pulses. The third chapter describes the development of such a laser system, the appeared and solved problems. The non linear effects and the energy losses are always the hardest problems at an amplifier system. Because of the necessary pulse stretching and compression, the pulse suffers significant energy loss. The non-linear affects cause spectral narrowing in the amplifier crystal. These disadvantages can be compensated and corrected by the use of the pulse shaping techniques, like the acustooptic modulator, LCD. The end of the chapter describes results of the development: after optimisation all of the possible parameters were measured, the energy and the duration of the output pulse: 3 mJ at 12 fs. The first application of the system was the High Harmonic Generation. The conventional technique based on a gas target, in which the laser beam is focused strongly. The fourth chapter describes the theoretic possibilities and limits of the process: in the microscopic (HH generation) and the macroscopic (pulse propagation) metric. These drawbacks can be compensated by the non adiabatic self phase matching, which was already detailed in the literature. This technique based on the strongly focusing of the very short laser pulses into the gas target and its application made possible to generate X-ray photons up to 3.5 keV. With these pulses were carried out the static spectroscopic experiments. The recorded spectra shows nice absorption edges at the Titanium, Copper, Neon and Platinum. The number of the genereated X-ray photons was enough to make EXAFS measurements. The fifth chapter shows the measured spectra, the evaluated EXAFS spectra with the estimated atomic distances of the silicon, titanium and copper. The time resolution of the pump-probe measurements was less than 20 fs. It was realized in two regimes: from 0-100 ps and from 0-1ps. The determined time constants are in good agreement with the literature values. KW - Röntgenabsorptionsspektroskopie KW - Femtosekundenspektroskopie KW - HHG KW - keV KW - zeitaufgelöste Spektroskopie KW - fs KW - HHG KW - keV KW - timeresolved spectroscopy KW - fs Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-16417 ER - TY - THES A1 - Semmel, Julia Birgit T1 - Herstellung von Quantenkaskadenlaserstrukturen auf InP und Entwicklung alternativer Bauteilkonzepte für den monomodigen Betrieb T1 - Quantumcascadelaserstructures on InP and development of alternative device concepts for single-mode emission N2 - Das zentrale Thema der vorliegenden Arbeit ist die Konzeptionierung und Charakterisierung verschiedener innovativer Bauteildesigns zur Optimierung der spektralen sowie elektro-optischen Eigenschaften von Quantenkaskadenlasern. Die Quantenkaskadenlaserschichten, die diesen Konzepten zu Grunde liegen wurden im Rahmen dieser Arbeit mittels Molekularstrahlepitaxie hergestellt und optimiert. Diese Optimierung machte auch die Realisierung von Dauerstrichbetrieb möglich. Dazu werden zunächst die grundlegenden Eigenschaften von den in dieser Arbeit verwendeten III-V-Halbleitern sowie des InP-Materialsystems erläutert. Für diese Arbeit ist dabei die Kombination der beiden ternären Verbindungshalbleiter InGaAs und InAlAs in einer Halbleiterheterostruktur von zentraler Bedeutung, aus denen die aktive Zone der hier vorgestellten Quantenkaskadenlaser besteht. Basierend auf dem zweiten Kapitel wird dann im dritten Kapitel auf das Zusammenspiel der einzelnen konkurrierenden strahlenden und nicht strahlenden Streuprozesse in einer Quantenkaskadenlaserstruktur eingegangen. Dabei wird die prinzipielle Funktionsweise eines solchen komplexen Systems an Hand eines 3-Quantenfilm-Designs erläutert. Das vierte Kapitel beschäftigt sich mit der Herstellung und Grundcharakterisierung der Laserstrukturen. Dabei wird kurz das Konzept der Molekularstrahlepitaxie erklärt sowie der Aufbau der verwendeten Anlage beschrieben. Da ein Betrieb der Bauteile im Dauerstrichbetrieb deren Anwendbarkeit in vielen Bereichen verbessert, wird im fünften Kapitel an Hand eines ausgewählten Strukturdesigns der Weg bis hin zur Realisierung des Dauerstrichbetriebs beschrieben. Des Weiteren wird auf einen besonderen Prozess zur Verbesserung der Wärmeleitfähigkeit der fertigen Bauteile eingegangen. Dieser sogenannte Doppelkanal-Stegwellenleiter-Prozess zeichnet sich dadurch aus, dass der entstehende Lasersteg seitlich durch zwei nasschemisch geätzte Gräben begrenzt wird.Die letzten drei Kapitel beschäftigen sich mit verschiedenen Bauteilkonzepten zur Optimierung der spektralen sowie elektro-optischen Eigenschaften der Quantenkaskadenlaser. In Kapitel sechs werden dabei Mikrolaser mit tiefgeätzten Bragg-Spiegeln zur Realisierung von monomodigem Betrieb vorgestellt. Im folgenden Kapitel werden Laser mit aktiven gekoppelten Ringresonatoren vorgestellt. Der gekoppelte Ring funktioniert dabei als Filter nach dem Vernier-Prinzip und ermöglicht so monomodigen Betrieb. Im letzten Kapitel stehen schließlich Quantenkaskadenlaser mit trapezförmigem Verstärkungsbereich im Mittelpunkt. Ziel dieses Teils der vorliegenden Arbeit war es die Ausgangsleistung der Bauteile zu erhöhen und dabei gleichzeitig die Fernfeldeigenschaften zu verbessern. N2 - Central topic of this work is the fabrication and characterization of various quantum cascade laser structures. Different concepts for optimizing the spectral as well as the electro-optical properties of quantum cascade laser devices have been investigated. In the second chapter the basic properties of III-V-compound semiconductors and those of the InP-materialsystem are explained. The composition of the two ternary compound semiconductors InGaAs and InAlAs, of which the active region of the quantum cascade laser structures introduced in this work consists, is essential for this work. Based on the second chapter the third chapter deals with the interplay of the individual radiative and non-radiative scattering processes in a quantum cascade laser structure. The principle operation mode of such a complex system is explained using a 3-quantum-well-design as a model system. The fourth chapter focuses on the fabrication and basic characterization of the laser structures. The basic concept of molecular beam epitaxy is explained as well as the configuration of the used molecular beam epitaxy system. Continuous wave operation paves the way for a better applicability in most areas, where lasers in the mid-infrared wavelength regime are needed. Therefore in the fifth chapter the realization of continuous wave operation is shown using one of the grown laser structures as an example. Furthermore a special processing technique involving chemical wet etching is described, which promises an improved heat dissipation in the devices. In this double-channel process the laser ridge is laterally defined by two trenches, which after an insulating step are then filled with electroplated gold. The last three chapters concentrate on various device designs having the potential of optimizing the spectral as well as the electro-optical properties of the quantum cascade laser devices. Microlasers with deeply etched distributed Bragg reflectors in order to obtain single mode emission are introduced in chapter six. In the following chapter ridge waveguides devices with coupled active ring resonators that function as a filter following the Vernier-principle are introduced. With this approach single-mode emission is achieved. The last chapter finally focusses on quantum cascade lasers with tapered gain sections. This device concept allows for higher output powers and improved horizontal far-field properties as compared to regular ridge waveguides and in consequence an improved coupling efficiency. KW - Quantenkaskadenlaser KW - Indiumphosphid KW - Halbleiterlaser KW - Optoelektronik KW - Molekularstrahlepitaxie KW - semiconductor laser KW - quantumcascade laser KW - opto electronics KW - molecular beam epitaxy Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-53483 ER - TY - THES A1 - Selle, Reimer Andreas T1 - Adaptive Polarization Pulse Shaping and Modeling of Light-Matter Interactions with Neural Networks T1 - Adaptive Polarisationspulsformung und Modellierung von Licht-Materie-Wechselwirkungen mit Neuronalen Netzwerken N2 - The technique of ultrafast polarization shaping is applied to a model quantum system, the potassium dimer. The polarization dependence of the multiphoton ionization dynamics in this molecule is first investigated in pump–probe experiments, and it is then more generally addressed and exploited in an adaptive quantum control experiment utilizing near–IR polarization–shaped laser pulses. The extension of these polarization shaping techniques to the UV spectral range is presented, and methods for the generation and characterization of polarization–shaped laser pulses in the UV are introduced. Systematic scans of double–pulse sequences are introduced for the investigation and interpretation of control mechanisms. This concept is first introduced and illustrated for an optical demonstration experiment, and it is then applied for the analysis of the intrapulse dumping mechanism that is observed in the excitation of a large dye molecule in solution with ultrashort laser pulses. Shaped laser pulses are employed as a means for obtaining copious amounts of data on light–matter interactions. Neural networks are introduced as a novel tool for generating computer–based models for these interactions from the accumulated data. The viability of this approach is first tested for second harmonic generation (SHG) and molecular fluorescence processes. Neural networks are then utilized for modeling the far more complex coherent strong–field dynamics of potassium atoms. N2 - Die Technik der ultraschnellen Polarisationspulsformung wird auf ein Modell-Quantensystem, das Kalium-Dimer angewandt. Die Polarisationsabhängigkeit der Ionisationsdynamik wird zunächst mit Anrege-Abfrage-Experimenten untersucht, und anschließend in einem adaptiven Optimierungsexperiment mit polarisationsgeformten Nahinfrarot-Laserpulsen ausgenutzt. Die Polarisationspulsformungstechnik wird auf den ultravioletten Spektralbereich erweitert, und es werden Methoden zur Erzeugung und Charakterisierung von polarisationsgeformten UV-Pulsen vorgestellt. Systematische Abtastungen von Doppelpulsfolgen werden für die Untersuchung und Interpretation von Kontrollmechanismen vorgestellt. Geformte Laserpulse werden verwendet, um umfangreiche Daten über die Licht-Materie Wechselwirkung zu sammeln. Neuronale Netzwerke werden erstmals dazu verwendet, um aus den Daten numerische Modelle für die Wechselwirkung von Licht und Materie zu erzeugen. Die Durchführbarkeit dieses Ansatzes wird zunächst an SHG und Fluoreszenzprozessen demonstriert. Neuronale Netzwerke werden desweiteren dazu verwendet, um die weitaus komplexere Dynamik von Kaliumatomen in starken elektromagnetischen Feldern zu modellieren. KW - Lasertechnologie KW - Impulslaser KW - Optimale Kontrolle KW - Pulsformung KW - Neuronale Netzwerke KW - adaptive Optimierung KW - Polarisation KW - pulse shaping KW - neural networks KW - adaptive optimization KW - polarization Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-25596 ER - TY - THES A1 - Seiberlich, Nicole T1 - Advances in Non-Cartesian Parallel Magnetic Resonance Imaging using the GRAPPA Operator T1 - Fortschritte in der nicht-kartesischen parallelen Magnetresonanztomographie mittels des GRAPPA-Operators N2 - Magnetic Resonance Imaging (MRI) is an imaging modality which provides anatomical or functional images of the human body with variable contrasts in an arbitrarily positioned slice without the need for ionizing radiation. In MRI, data are not acquired directly, but in the reciprocal image space (otherwise known as k-space) through the application of spatially variable magnetic field gradients. The k-space is made up of a grid of data points which are generally acquired in a line-by-line fashion (Cartesian imaging). After the acquisition, the k-space data are transformed into the image domain using the Fast Fourier Transformation (FFT). However, the acquisition of data is not limited to the rectilinear Cartesian sampling scheme described above. Non-Cartesian acquisitions, where the data are collected along exotic trajectories, such as radial and spiral, have been shown to be beneficial in a number of applications. However, despite their additional properties and potential advantages, working with non-Cartesian data can be complicated. The primary difficulty is that non-Cartesian trajectories are made up of points which do not fall on a Cartesian grid, and a simple and fast FFT algorithm cannot be employed to reconstruct images from non-Cartesian data. In order to create an image, the non-Cartesian data are generally resampled on a Cartesian grid, an operation known as gridding, before the FFT is performed. Another challenge for non-Cartesian imaging is the combination of unusual trajectories with parallel imaging. This thesis has presented several new non-Cartesian parallel imaging methods which simplify both gridding and the reconstruction of images from undersampled data. In Chapter 4, a novel approach which uses the concepts of parallel imaging to grid data sampled along a non-Cartesian trajectory called GRAPPA Operator Gridding (GROG) is described. GROG shifts any acquired k-space data point to its nearest Cartesian location, thereby converting non-Cartesian to Cartesian data. The only requirements for GROG are a multi-channel acquisition and a calibration dataset for the determination of the GROG weights. Chapter 5 discusses an extension of GRAPPA Operator Gridding, namely Self-Calibrating GRAPPA Operator Gridding (SC-GROG). SC-GROG is a method by which non-Cartesian data can be gridded using spatial information from a multi-channel coil array without the need for an additional calibration dataset, as required in standard GROG. Although GROG can be used to grid undersampled datasets, it is important to note that this method uses parallel imaging only for gridding, and not to reconstruct artifact-free images from undersampled data. Chapter 6 introduces a simple, novel method for performing modified Cartesian GRAPPA reconstructions on undersampled non-Cartesian k-space data gridded using GROG to arrive at a non-aliased image. Because the undersampled non-Cartesian data cannot be reconstructed using a single GRAPPA kernel, several Cartesian patterns are selected for the reconstruction. Finally, Chapter 7 discusses a novel method of using GROG to mimic the bunched phase encoding acquisition (BPE) scheme. In MRI, it is generally assumed that an artifact-free image can be reconstructed only from sampled points which fulfill the Nyquist criterion. However, the BPE reconstruction is based on the Generalized Sampling Theorem of Papoulis, which states that a continuous signal can be reconstructed from sampled points as long as the points are on average sampled at the Nyquist frequency. A novel method of generating the “bunched” data using GRAPPA Operator Gridding (GROG), which shifts datapoints by small distances in k-space using the GRAPPA Operator instead of employing zig-zag shaped gradients, is presented in this chapter. With the conjugate gradient reconstruction method, these additional “bunched” points can then be used to reconstruct an artifact-free image from undersampled data. This method is referred to as GROG-facilitated Bunched Phase Encoding, or GROG-BPE. N2 - Die Magnetresonanztomographie (MRT) ist ein nichtinvasives bildgebendes Verfahren ohne Strahlenbelastung und eignet sich zur biomedizinischen Darstellung verschiedener Gewebetypen mit hoher räumlicher Auflösung und sehr gutem Kontrastverhalten. In der MRT erfolgt die Datenaufnahme im reziproken Bildraum – auch k-Raum genannt - welcher typischerweise entlang eines diskreten kartesischen Gitters abgetastet wird. Ein Bild erhält man schließlich durch eine schnelle Fouriertransformation der aufgenommenen k-Raum-Daten. Neben den kartesischen Akquisitionsschemata haben sich in den letzten Jahren auch vereinzelt nichtkartesische MRT-Verfahren in der klinischen Routine durchgesetzt. Solche nichtkartesischen Trajektorien erreichen eine hohe Abtasteffizienz, was zu einer Verkürzung der Messzeit führt. Die Schwierigkeit im Umgang mit nichtkartesischen Trajektorien liegt vor allem in der Tatsache begründet, dass nichtkartesisch akquirierte Datensätze vor Anwendung der schnellen Fouriertransformation auf ein kartesisches Gitter transformiert werden müssen („Gridding“). Hierzu gibt es eine Vielzahl von Verfahren, die von zahlreichen Parametern abhängen, womit ein hoher Aufwand und hohe Fehleranfälligkeit verbunden sind. Ein weiterer Nachteil dieser Gridding-Methoden ist, dass sie auf unvollständig aufgenommene Datensätze nicht angewendet werden können. Alternativ zu den konventionellen MR-Verfahren haben sich in den letzten Jahren die sogenannten parallelen Bildgebungsmethoden (beispielsweise SENSE oder GRAPPA) in der klinischen MRT etabliert, die mittlerweile von nahezu allen Herstellerfirmen kommerziell zur Verfügung gestellt werden. Die parallele Bildgebung erlaubt es, die Bildmesszeiten um einen Faktor 2 bis 4 zu verkürzen und lässt sich prinzipiell auf jede beliebige Bilgebungsmethode anwenden ohne dabei das Kontrastverhalten zu beeinflussen. In der klinischen Routine ist diese Technik allerdings lediglich auf kartesische MRT-Verfahren beschränkt, und es ist bisher noch nicht gelungen, die Vorteile der nichtkartesischen MRT-Verfahren optimal mit den Leistungsmerkmalen der parallelen MRT zu verknüpfen. Ziel dieser Arbeit war es, neue und effiziente Strategien zu entwickeln, um die nichtkartesische Magnetresonanztomographie für ein breiteres Anwendungsspektrum in der klinischen Praxis zu etablieren. Neben der Rekonstruktion von herkömmlich aufgenommenen nichtkartesischen Datensätzen sollten auch Verfahren entwickelt werden, die eine Kombination mit Messzeitverkürzungen durch parallele MRT-Verfahren erlauben. In Kapitel 4 wird ein neues paralleles Bildgebungsverfahren zum Gridding nichtkartesischer Datensätze namens „GRAPPA Operator Gridding“ (GROG) vorgestellt. GROG benutzt GRAPPA-ähnliche Gewichtungsfaktoren, um die nichtkartesischen Punkte auf ein kartesisches Gitter zu schieben. Im Gegensatz zu anderen Gridding-Methoden (wie beispielsweise dem „Convolution-Gridding“) werden bei der Anwendung von GROG Parameter wie Faltungskerne, Regularisierungswerte oder Funktionen nicht benötigt. Dies führt nicht nur zu einer erheblichen Vereinfachung des Griddingprozesses, sondern auch zur deutlichen Reduktion der Rechenoperationen. In Kapitel 5 wird eine Erweiterung des GROG-Algorithmus vorgestellt, welche ohne Kalibrierungsdatensätze auskommt („Self-Calibrating GROG“, SC-GROG). Die Gewichtungsfaktoren für die Verschiebungen der Datenpunkte werden in dieser Methode aus den akquirierten Punkten selbst gewonnen. Die erste Anwendung von GROG zur Vereinfachung der Rekonstruktion unvollständig aufgenommener nichtkartesischer Datensätze ist in Kapitel 6 beschrieben. Die Verwendung von GROG zur Transformation der unvollständig aufgenommenen nichtkartesischen Daten auf ein kartesisches Gitter erlaubt es, anschließend einen modifizierten GRAPPA-Algorithmus anzuwenden, und somit nichtkartesische Datensätze aus beschleunigten Experimenten zu rekonstruieren. Schließlich wurde GROG in Kapitel 7 auf die „Bunched Phase Encoding“ (BPE)-Methode angewendet. Bereits zuvor wurde gezeigt, dass das BPE-Verfahren in Verbindung mit einem „Conjugate Gradient“ Rekonstruktionsverfahren eine deutliche Verkürzung der Messzeit gestattet. Basierend auf dem verallgemeinerten Abtasttheorem nach Papoulis werden die Daten bei diesem Verfahren entlang einer extrem schnell oszillierenden Trajektorie aufgenommen. Nach Papoulis ermöglicht die lokal höhere Datendichte eine artefaktfreie Bildrekonstruktion trotz Unterabtastung in anderen k-Raumbereichen. Allerdings werden dabei erhebliche Ansprüche an die Gradienten-Hardware des Tomographen gestellt, wodurch das Konzept auf geringe Beschleunigungsfaktoren beschränkt wird. Im Rahmen dieser Arbeit konnte jedoch gezeigt werden, dass es möglich ist, auf dieses aufwändige Abtastschema zu verzichten, indem lediglich entlang einer regulären nicht-oszillierenden Trajektorie akquiriert wird und die höhere Datendichte nachträglich mittels GROG erreicht wird (GROG-BPE). KW - NMR-Tomographie KW - Bildgebendes Verfahren KW - Parallele Bildgebung KW - nicht-kartesische Bildgebung KW - Magnetic Resonance Imaging KW - Parallel Imaging KW - non-Cartesian Imaging KW - Image Reconstruction Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-28321 ER - TY - THES A1 - Seibel, Christoph T1 - Elektronische Struktur von Halbleiteroberflächen mit starker Spin-Bahn-Wechselwirkung: Topologie, Spinpolarisation und Robustheit T1 - Electronic structure of semiconductor surfaces with strong spin-orbit interactions: topology, spin polarisation and robustness N2 - Neue Erkenntnisse über elektronische Eigenschaften von Festkörpern legen den Grundstein für innovative Anwendungen der Zukunft. Von zentraler Bedeutung sind insbesondere die Eigenschaften der Elektronenspins. Um diese besser zu verstehen, befasst sich die vorliegende Arbeit mit der experimentellen Analyse der elektronischen Struktur von topologischen Isolatoren (Sb$_2$Te$_3$ , Bi$_2$Se$_x$Te$_{3−x}$, Bi$_{1.5}$Sb$_{0.5}$Te$_{1.8}$Se$_{1.2} und Bi$_{1.4}$Sb$_{1.1}$Te$_{2.2}$S$_{0.3}$) und Kristallen mit starker Spin-Bahn-Wechselwirkung (BiTeI) mittels Photoelektronenspektroskopie. Zu Beginn werden die zum Verständnis dieser Arbeit benötigten Grundlagen erklärt sowie die unterschiedlichen zum Einsatz kommenden Techniken eingeführt. Der Hauptteil der Arbeit teilt sich in drei Forschungsschwerpunkte. Der erste Teil befasst sich mit den elektronischen Eigenschaften der Valenzbandstruktur von Sb2Te3 und den auftretenden Oberflächenzuständen. Durch gezielte Variation der Energie der anregenden Strahlung wird der Charakter der Wellenfunktion des topologischen Oberflächenzustands und dessen Wechselwirkung mit Valenzzuständen erforscht. Dabei spielt die Topologie der Volumenbandstruktur eine grundlegende Rolle. Der zusätzliche Vergleich zu Photoemissionsrechnungen ermöglicht detaillierte Einblicke in die Wechselwirkung zwischen Oberflächen- und Volumenzuständen und gibt Aufschluss darüber, wie diese vermittelt werden. Im zweiten Abschnitt wird durch die Analyse des gemessenen Photoelektronenspins das Zusammenspiel der Spintextur des Grundzustands und Endzuständen in Bi2Te3 untersucht. Dabei treten, im Gegensatz zu Grundzustandsrechnungen, Radialkomponenten des Polarisationsvektors in nichtsymmetrischer Messgeometrie auf. Sowohl deren Energieabhängigkeit als auch deren Auftreten in Photoemissionsrechnungen (1-Schritt-Modell) deutet darauf hin, dass diese ihren Ursprung in Übergangsmatrixelementen des Photoemissionsprozesses haben. Dieses Ergebnis wird mit Spinpolarisationsmessungen am Oberflächenzustand des nicht-topologischen Schichtsystems BiTeI verglichen. Im dritten Teil werden Auswirkungen unterschiedlicher Manipulationen der untersuchten Materialien auf deren elektronische Eigenschaften beschrieben. Die Adsorption von Bruchteilen einer monoatomaren Lage des Alkalimetalls Caesium auf die Oberfläche des topologischen Isolators Sb2Te3 wird systematisch untersucht. Dadurch kann dessen intrinsische p-Dotierung teilweise abgebaut werden, wobei die Valenzbandstruktur trotz der Reaktivität des Adsorbats intakt bleibt. Des Weiteren werden Auswirkungen von Änderungen der Kristallstöchiometrie durch Volumendotierung vergleichend diskutiert. Ausblickend befasst sich das Kapitel mit dem Verhalten geringer Mengen ferromagnetischer Materialen (Fe, Ni) auf den Oberflächen der topologischen Isolatoren. Für die verschiedenen Adsorbate werden Trends aufgezeigt, die von Temperatur und Zusammensetzung des Substratkristalls abhängen. N2 - New findings about electronic properties lay the foundation for future applications. The spin properties of systems with large spin-orbit coupling are particularly important. The content of this thesis therefore treats the experimental study of the surface electronic structure of topological insulators (Sb$_2$Te$_3$ , Bi$_2$Se$_x$Te$_{3−x}$, Bi$_{1.5}$Sb$_{0.5}$Te$_{1.8}$Se$_{1.2} and Bi$_{1.4}$Sb$_{1.1}$Te$_{2.2}$S$_{0.3}$) and topologically trivial BiTeI crystals using photoelectron spectroscopy. At the beginning basic knowledge to understand this thesis, as well as exploited techniques are addressed. The main part of this thesis separates into three research topics. The first part focuses on the electronic properties of the valence band structure and the wave functions of the occuring surface states. Via variation of the energy of the exciting radiation the character of the wavefunction of the respective topologically non trivial surface state as well as its interaction with valence states is explored. The bulk boundary correspondence and the topology of the bulk electronic structure is of special importance for this interaction. Additionally, it is concluded from photoemission calculations, that the interaction between surface and bulk valence states is mediated by a surface resonance state. The second section presents an analysis of photoelectron spins to investigate the respective contributions of the spin texture of the initial state and final states. This thesis reports on non-vanishing radial components of the polarization vector which do not appear in groundstate calculations. The energy dependance in combination with one-step photoemission calculations indicates that these radial components find their origin in transition matrix elements of the photoemission process. The result is compared to spin resolved measurements of the surface state of the layered material BiTeI which is not a topological insulator. In the third part the consequences of various manipulations of the analyzed materials on their respective electronic structure are described. The systematic adsorption of submonolayer amounts of the alkalimetal Caesium on the surface of the topological insulator Sb2Te3(0001) reduces its intrinsic p-doping without altering its valence band structure despite the reactivity of the adsorbate. Furthermore the effects of stoichiometric changes of elemental composition and bulk doping are being discussed. Finally the behavior of small amounts of ferromagnetic materials (Fe, Ni) on the surface of the respective topological insulators are being addressed. For the different adsorbates trends are shown, which depend on temperature and chemical composition of the substrate. KW - Elektronenstruktur KW - Topologischer Isolator KW - Sb2Te3 KW - ARPES Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-140418 ER - TY - THES A1 - Schütz, Philipp T1 - Dimensionality-Driven Metal-Insulator Transition in Spin-Orbit-Coupled SrIrO\(_3\) T1 - Dimensionalitätsgetriebener Metal-Isolator-Übergang in Spin-Bahn-gekoppeltem SrIrO\(_3\) N2 - In the past decades correlated-electron physics due to strong Coulomb interactions and topological physics caused by band inversion often induced by strong spin-orbit coupling have been the workhorses of solid state research. While commonly considered as disparate phenomena, it was realized in the early 2010s that the interplay between the comparably strong Coulomb and spin-orbit interactions in the $5d$ transition metal oxides may result in hitherto unforeseen properties. The layered perovskite Sr$\textsubscript{2}$IrO$\textsubscript{4}$ has attracted special attention due to the observation of an unconventional Mott-insulating phase and predictions of exotic superconductivity. Less is known about its three-dimensional counterpart SrIrO$\textsubscript{3}$, since rather than the cubic perovskite structure it adopts the thermodynamically stable hexagonal polymorph thereof. This thesis therefore sets out to establish the synthesis of epitaxially stabilized perovskite SrIrO$\textsubscript{3}$ by pulsed laser deposition and to investigate its electronic and magnetic structure by state-of-the-art x-ray spectroscopy techniques. In this endeavor the appropriate thermodynamic conditions for the growth of high-quality SrIrO$\textsubscript{3}$ are identified with a focus on the prevention of cation off-stoichiometry and the sustainment of layer-by-layer growth. In the thus-optimized films the cubic perovskite symmetry is broken by a tetragonal distortion due to epitaxial strain and additional cooperative rotations of the IrO$\textsubscript{6}$ octahedra. As a consequence of the thermodynamic instability of the IrO$\textsubscript{2}$ surface layer, the films unexpectedly undergo a conversion to a SrO termination during growth. In an attempt to disentangle the interplay between spin-orbit and Coulomb interaction the three-dimensional electronic structure of perovskite SrIrO$\textsubscript{3}$ is investigated in a combined experimental and theoretical approach using soft x-ray angle-resolved photoelectron spectroscopy and \textit{ab initio} density functional theory calculations. The experimentally found metallic ground state hosts coherent quasiparticle peaks with a well-defined Fermi surface and is theoretically described by a single half-filled band with effective total angular momentum $J_\text{eff} = 1/2$ only upon incorporation of a sizeable local Coulomb repulsion and -- to a lesser extent -- the broken cubic crystal symmetry in the film. Upon reduction of the SrIrO$\textsubscript{3}$ thickness below a threshold of four unit cells the scales are tipped in favor of a Mott-insulating phase as the on-site Coulomb repulsion surmounts the diminishing kinetic energy upon transition into the two-dimensional regime. Concomitantly, a structural transition occurs because the corner-shared octahedral network between substrate and film imposes constraints upon the IrO$\textsubscript{6}$ octahedral rotations in the thin-film limit. The striking similarity between the quasi-two-dimensional spin-orbit-induced Mott insulator Sr$\textsubscript{2}$IrO$\textsubscript{4}$ and SrO-terminated SrIrO$\textsubscript{3}$ in the monolayer limit underlines the importance of dimensionality for the metal-insulator transition and possibly opens a new avenue towards the realization of exotic superconductivity in iridate compounds. Whether the analogy between SrIrO$\textsubscript{3}$ in the two-dimensional limit and its Ruddlesden-Popper bulk counterparts extends to their complex magnetic properties ultimately remains an open question, although no indications for a remanent (anti)ferromagnetic order were found. The unprecedented observation of an x-ray magnetic circular dichroism at the O~$K$-absorption edge of iridium oxides in an external magnetic field promises deeper insights into the intricate connection between the $J_\text{eff} = 1/2$ pseudospin state, its hybridization with the oxygen ligand states and the magnetic order found in the Ruddlesden-Popper iridates. N2 - In den vergangenen Jahrzehnten waren die Physik korrelierter Elektronen aufgrund starker Coulomb- sowie topologische Physik aufgrund durch Spin-Bahn-Wechselwirkung induzierter Bandinversion die Zugpferde der Festkörperforschung. Während diese zuvor gemeinhin als disjunkt wahrgenommen wurden, setzte sich Anfang der 2010er Jahre die Einsicht durch, dass das Zusammenspiel der ähnlich starken Coulomb- und Spin-Bahn-Wechselwirkung in $5d$ Übergangsmetalloxiden zu unvorhergesehenen Eigenschaften führen kann. Bedingt durch die Entdeckung einer unkonventionellen Mott-isolierenden Phase sowie Vorhersagen exotischer Supraleitung wurde dem geschichteten Perowskit Sr$\textsubscript{2}$IrO$\textsubscript{4}$ besondere Aufmerksamkeit zuteil. Über dessen dreidimensionales Pendant SrIrO$\textsubscript{3}$ ist weniger bekannt, da es anstelle der kubischen Perowskitstruktur eine thermodynamisch stabilere polymorphe Gitterstruktur annimmt. Ziel dieser Thesis ist daher die Synthese von epitaktisch stabilisiertem Perowskit-SrIrO$\textsubscript{3}$ mittels gepulster Laserablation sowie die Untersuchung dessen elektronischer und magnetischer Struktur mit modernsten Röntgenspektroskopiemethoden. In diesem Bestreben werden zunächst die thermodynamischen Bedingungen für das Wachstum von qualitativ hochwertigem SrIrO$\textsubscript{3}$ mit dem Fokus auf der kationischen Stöchiometrie sowie dem Erreichen lagenweisen Schichtwachstums identifiziert. In derart optimierten Filmen wird die kubische Symmetrie von einer tetragonalen Verzerrung aufgrund epitaktischer Verspannung sowie von kooperativen Verdrehungen der IrO$\textsubscript{6}$ Oktaeder gebrochen. Während des Wachstums findet infolge der thermodynamischen Instabilität der obersten IrO$\textsubscript{2}$ Lage eine Umwandlung zu einer SrO-Terminierung der Oberfläche statt. Mit dem Ziel das Zusammenspiel von Spin-Bahn- und Coulomb-Wechselwirkung in SrIrO$\textsubscript{3}$ zu entwirren wird dessen dreidimensionale elektronische Struktur in Kombination von winkelaufgelöster Photoelektronenspektroskopie im weichen Röntgenbereich und \textit{ab initio} Dichtefunktionaltheorie untersucht. Der experimentell beobachtete metallische Grundzustand weist kohärente Quasiteilchenzustände mit wohldefinierter Fermifläche auf und wird theoretisch durch ein halbgefülltes Band mit effektivem Gesamtdrehmoment $J_\text{eff} =1/2$ beschrieben, sofern eine substanzielle lokale Coulombabstoßung sowie - in geringerem Maße - die gebrochene kubische Symmetrie berücksichtigt werden. Bei Schichtdicken unterhalb von vier Einheitszellen neigt sich das Gleichgewicht zugunsten einer Mott-isolierenden Phase, da die lokale Coulombabstoßung die im Zweidimensionalen reduzierte kinetische Energie zunehmend überwiegt. Gleichzeitig findet ein struktureller Übergang statt, da das Netzwerk aus Sauerstoffoktaedern deren Rotationen in dünnen Filmen Randbedingungen auferlegt. Die verblüffende Ähnlichkeit zwischen dem quasi-zweidimensionalen Mott-Isolator Sr$\textsubscript{2}$IrO$\textsubscript{4}$ und SrO-terminiertem Monolagen-SrIrO$\textsubscript{3}$ unterstreicht die Bedeutung der Dimensionalität für den Metall-Isolator-Übergang und eröffnet neue Möglichkeiten zur Realisierung exotischer Supraleitung in Iridaten. Die Frage, ob sich die Analogie zwischen SrIrO$\textsubscript{3}$ im zweidimensionalen Limes und den quasi-zweidimensionalen Ruddlesden-Popper-Iridaten auf deren komplexe magnetische Eigenschaften erstreckt, bleibt schlussendlich offen, gleichwohl keine Hinweise auf eine remanente (anti-)ferromagnetische Ordnung hindeuten. Die bisher erste Beobachtung eines magnetischen Zirkulardichroismus an der O~$K$-Absorptionskante eines Iridiumoxids in einem externen Magnetfeld verspricht tiefere Einsichten in den komplexen Zusammenhang zwischen dem $J_\text{eff} = 1/2$ Pseudospin-Zustand, dessen Hybridisierung mit den Valenzzuständen der Sauerstoffliganden sowie der magnetischen Ordnung in Iridatverbindungen. KW - Festkörperphysik Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-212781 ER - TY - THES A1 - Schömig, Herbert Richard T1 - Nanooptik an breitbandlückigen Halbleiter-Nanostrukturen für die Spintronik und Optoelektronik T1 - Nanooptics on wide-bandgap semiconductor nanostructures for spintronics and optoelectronics N2 - Die vorliegende Arbeit behandelt drei Themen aus der Forschung an nanostrukturierten Halbleitern im Umfeld der Spintronik und Optoelektronik. 1) Einzelne semimagnetische Quantenpunkte Mn-dotierte, und damit semimagnetische Halbleiter zeichnen sich durch eine sp-d-Austauschkopplung zwischen den freien Ladungsträgerspins und den Mn-Spins aus. Für ein optisch injiziertes Exziton bedeutet dies eine Austauschenergie, die sich proportional zur Mn-Magnetisierung im Exzitonvolumen verhält. Lokalisiert man das Exziton in einem Quantenpunkt, so kann man es als Sonde für die Magnetisierung in der Nanoumgebung gebrauchen. Bedingung hierfür ist die spektroskopische Selektion einzelner Quantenpunkte. Die Selektion einzelner CdSe/ZnMnSe-Quantenpunkte konnte realisiert werden durch die lithographische Präparation einer lichtundurchlässigen Metallmaske auf der Probenoberfläche, versehen mit nanoskaligen Aperturen. Die Photolumineszenz(PL)-Emission an diesen Aperturen zeigt individuelle PL-Linien entsprechend einzelner Quantenpunkte. Mittels Magneto-PL-Spektroskopie gelingt es das magnetische Moment einzelner Quantenpunkte von wenigen 10 Bohrmagneton sowie die thermische Fluktuation dieses Moments aufzuklären. Sowohl die Temperatur- als auch die Magnetfeldabhängigkeit der Exziton-Mn-Kopplung werden im Rahmen eines modifizierten Brillouinmodells konsistent beschrieben. 2) Ferromagnet-DMS-Hybride Eine lokale Beeinflussung von Spins im Halbleiter wird möglich durch die Präparation von ferromagnetischen Strukturen auf der Halbleiteroberfläche. Die magnetischen Streufelder, welche von nanostrukturierten Ferromagneten (FM) erzeugt werden, können auf mesoskopischer Längenskala eine Verbiegung der Spinbänder in einem Quantenfilm bewirken. Dies gilt insbesondere für einen semimagnetischen (DMS-)Quantenfilm vom Typ ZnCdMnSe/ZnSe, wie er im vorliegenden Fall Verwendung fand. Aufgrund der Verstärkerfunktion der Mn-Spins liegen hier nämlich riesige effektive g-Faktoren vor, welche im Magnetfeld große Spinaufspaltungen produzieren. Wie magnetostatische Rechnungen für Drahtstrukturen aus ferromagnetischem Dysprosium (Dy) offenlegen, sind bei senkrechter Magnetisierung Streufelder in der Größenordung von 0.1 bis 1 T in der Quantenfilmebene darstellbar. Magneto-PL-Messungen mit hoher Ortsauflösung demonstrieren tatsächlich einen Einfluß der nanostrukturierten Ferromagnete auf die exzitonischen Spinzustände im Quantenfilm und erlauben zudem einen Rückschluß auf die magnetische Charakteristik der FM-Nanostrukturen. 3) Einzelne Lokalisationszentren in InGaN/GaN-Quantenfilmen Die Lokalisation der Ladungsträger in nm-skaligen Materieinseln hat einen erheblichen Einfluss auf die optischen Eigenschaften eines InGaN-Quantenfilmes. Eine detaillierte Aufklärung dieses Effektes erfordert den reproduzierbaren, spektroskopischen Zugang zu einzelnen dieser Lokalisationszentren. Diese Bedingung wurde hier mit der Aufbringung einer Nanoaperturmaske auf der Halbleiteroberfläche erfüllt. PL-Spektren, gemessen an solchen Nanoaperturen bei einer Temperatur von 4 K, weisen tatsächlich einzelne, spektral scharfe Emissionlinien mit Halbwertsbreiten bis hinab zu 0.8 meV auf. Eine solche Einzellinie entspricht dabei der PL-Emission aus in einem einzelnen Lokalisationszentrum, welche an dieser Stelle erstmalig nachgewiesen werden konnte. In den folgenden Experimenten zeigte sich interessanterweise, dass diese Einzellinien gänzlich andere Abhängigkeiten an den Tag legen als das inhomogene PL-Signal eines großen Ensembles von Zentren. Dies ermöglichte eine fundierte Beurteilung bislang kontrovers diskutierter Mechanismen, welche für die PL-Charakteristik von InGaN-Quantenfilmen relevant sind. Als bestimmende Faktoren erwiesen sich das interne Piezofeld, der Bandfülleffekt und die Bildung von Multiexzitonen. N2 - This work treats three topics from the research on nanostructured semiconductors in the field of spintronics and optoelectronics. 1) Single semimagnetic quantum dots Semiconductors doped with Mn, so-called diluted magnetic semiconductors, exhibit an intense sp-d exchange interaction between free carrier spins and localized Mn spins. Due to this coupling an exciton, optically injected into the DMS semiconductor, acquires an exchange energy proportional to the Mn magnetization within the exciton volume. If the exciton localizes in a quantum dot it can be employed as a probe monitoring the magnetization in the nanoenvironment. However, this requires the spectroscopic selection of single quantum dots. In this work single CdSe/ZnMnSe quantum dots could be addressed with the help of an opaque metal mask on top of the semiconductor with nanoapertures prepared by electron lithography. The PL emission from such nanoapertures shows individual PL lines corresponding to single quantum dots. By means of magneto-PL-spectroscopy the magnetic moment of single quantum dots of only some tens of Bohrmagnetons is addressed, including its thermal fluctuations. The temperature as well as magnetic field dependence of the exciton-Mn coupling is consistently described in the frame of a modified Brillouin model. 2) Ferromagnet-DMS-Hybrids A local manipulation of spins in a semiconductor can be realized by a preparation of ferromagnetic structures on the surface of a semiconductor. Magnetic fringe fields, emerging from nanostructured ferromagnets (FM) are capable of bending the spin bands of a buried quantum well on a mesoscopic length scale. This is especially valid for a semimagnetic quantum well like the ZnCdMnSe/ZnSe heterostructure used in the following experiments. Due to the drastic enhancement of the exciton g factor by the coupling to the Mn spins, huge spin splittings become possible. Magnetostatic calculations performed for ferromagnetic dysprosium (Dy) wire structures show, that fringe fields in the range of 0.1 to 1 T can be achieved in a perpendicular magnetization configuration. Magneto-PL measurements with a high spatial resolution actually demonstrate an influence of nanostructured ferromagnets on the excitonic spin bands in the quantum well and even provide some information about the magnetic characteristics of the FM nanoelements. 3) Single localization centers in a InGaN/GaN quantum well The localization of charge carriers in nm-sized islands has a strong influence on the optical properties of InGaN/GaN quantum wells. A detailed analysis of these effects require a reproduceable, spectroscopic access to single localization centers. This prerequisite has been fulfilled by depositing a mask with nanoapertures on the semiconductor surface. PL spectra measured on these nanoapertures at a temperature of 4 K reveal individual, spectrally narrow emission lines with a halfwidth down to 0.8 meV. Such a single PL line can be attributed to the emission from a single localization center. The optical access to single centers has been demonstrated here for the first time. As the following experiments showed, there is a profound difference between the behavior of such single PL lines and the inhomogenous PL signal from a large ensemble of centers. This gives a clear picture of the impact of some mechanisms relevant for the PL characteristics of InGaN quantum films, that have been the subject of a controversial debate. The most influential factors are the internal piezo electric field, the bandfilling effect and the formation of multiexcitons. KW - Cadmiumselenid KW - Zinkselenid KW - Manganselenide KW - Semimagnetischer Halbleiter KW - Quantenpunkt KW - Halbleiteroberfläche KW - Ferromagnetische Schicht KW - Nanostruktur KW - Spin KW - Indiumnitrid KW - Galliumnitrid KW - Ferromagnete KW - Photolumineszenz KW - Quantum dots KW - semimagnetic semiconductors Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126558 N1 - Dieses Dokument wurde aus Datenschutzgründen - ohne inhaltliche Änderungen - erneut veröffentlicht. Die ursprüngliche Veröffentlichung war am: 22.10.2005 ER - TY - THES A1 - Schömig, Herbert Richard T1 - Nanooptik an breitbandlückigen Halbleiter-Nanostrukturen für die Spintronik und Optoelektronik T1 - Nanooptics on wide-bandgap semiconductor nanostructures for spintronics and optoelectronics N2 - Die vorliegende Arbeit behandelt drei Themen aus der Forschung an nanostrukturierten Halbleitern im Umfeld der Spintronik und Optoelektronik. 1) Einzelne semimagnetische Quantenpunkte Mn-dotierte, und damit semimagnetische Halbleiter zeichnen sich durch eine sp-d-Austauschkopplung zwischen den freien Ladungsträgerspins und den Mn-Spins aus. Für ein optisch injiziertes Exziton bedeutet dies eine Austauschenergie, die sich proportional zur Mn-Magnetisierung im Exzitonvolumen verhält. Lokalisiert man das Exziton in einem Quantenpunkt, so kann man es als Sonde für die Magnetisierung in der Nanoumgebung gebrauchen. Bedingung hierfür ist die spektroskopische Selektion einzelner Quantenpunkte. Die Selektion einzelner CdSe/ZnMnSe-Quantenpunkte konnte realisiert werden durch die lithographische Präparation einer lichtundurchlässigen Metallmaske auf der Probenoberfläche, versehen mit nanoskaligen Aperturen. Die Photolumineszenz(PL)-Emission an diesen Aperturen zeigt individuelle PL-Linien entsprechend einzelner Quantenpunkte. Mittels Magneto-PL-Spektroskopie gelingt es das magnetische Moment einzelner Quantenpunkte von wenigen 10 Bohrmagneton sowie die thermische Fluktuation dieses Moments aufzuklären. Sowohl die Temperatur- als auch die Magnetfeldabhängigkeit der Exziton-Mn-Kopplung werden im Rahmen eines modifizierten Brillouinmodells konsistent beschrieben. 2) Ferromagnet-DMS-Hybride Eine lokale Beeinflussung von Spins im Halbleiter wird möglich durch die Präparation von ferromagnetischen Strukturen auf der Halbleiteroberfläche. Die magnetischen Streufelder, welche von nanostrukturierten Ferromagneten (FM) erzeugt werden, können auf mesoskopischer Längenskala eine Verbiegung der Spinbänder in einem Quantenfilm bewirken. Dies gilt insbesondere für einen semimagnetischen (DMS-)Quantenfilm vom Typ ZnCdMnSe/ZnSe, wie er im vorliegenden Fall Verwendung fand. Aufgrund der Verstärkerfunktion der Mn-Spins liegen hier nämlich riesige effektive g-Faktoren vor, welche im Magnetfeld große Spinaufspaltungen produzieren. Wie magnetostatische Rechnungen für Drahtstrukturen aus ferromagnetischem Dysprosium (Dy) offenlegen, sind bei senkrechter Magnetisierung Streufelder in der Größenordung von 0.1 bis 1 T in der Quantenfilmebene darstellbar. Magneto-PL-Messungen mit hoher Ortsauflösung demonstrieren tatsächlich einen Einfluß der nanostrukturierten Ferromagnete auf die exzitonischen Spinzustände im Quantenfilm und erlauben zudem einen Rückschluß auf die magnetische Charakteristik der FM-Nanostrukturen. 3) Einzelne Lokalisationszentren in InGaN/GaN-Quantenfilmen Die Lokalisation der Ladungsträger in nm-skaligen Materieinseln hat einen erheblichen Einfluss auf die optischen Eigenschaften eines InGaN-Quantenfilmes. Eine detaillierte Aufklärung dieses Effektes erfordert den reproduzierbaren, spektroskopischen Zugang zu einzelnen dieser Lokalisationszentren. Diese Bedingung wurde hier mit der Aufbringung einer Nanoaperturmaske auf der Halbleiteroberfläche erfüllt. PL-Spektren, gemessen an solchen Nanoaperturen bei einer Temperatur von 4 K, weisen tatsächlich einzelne, spektral scharfe Emissionlinien mit Halbwertsbreiten bis hinab zu 0.8 meV auf. Eine solche Einzellinie entspricht dabei der PL-Emission aus in einem einzelnen Lokalisationszentrum, welche an dieser Stelle erstmalig nachgewiesen werden konnte. In den folgenden Experimenten zeigte sich interessanterweise, dass diese Einzellinien gänzlich andere Abhängigkeiten an den Tag legen als das inhomogene PL-Signal eines großen Ensembles von Zentren. Dies ermöglichte eine fundierte Beurteilung bislang kontrovers diskutierter Mechanismen, welche für die PL-Charakteristik von InGaN-Quantenfilmen relevant sind. Als bestimmende Faktoren erwiesen sich das interne Piezofeld, der Bandfülleffekt und die Bildung von Multiexzitonen. N2 - This work treats three topics from the research on nanostructured semiconductors in the field of spintronics and optoelectronics. 1) Single semimagnetic quantum dots Semiconductors doped with Mn, so-called diluted magnetic semiconductors, exhibit an intense sp-d exchange interaction between free carrier spins and localized Mn spins. Due to this coupling an exciton, optically injected into the DMS semiconductor, acquires an exchange energy proportional to the Mn magnetization within the exciton volume. If the exciton localizes in a quantum dot it can be employed as a probe monitoring the magnetization in the nanoenvironment. However, this requires the spectroscopic selection of single quantum dots. In this work single CdSe/ZnMnSe quantum dots could be addressed with the help of an opaque metal mask on top of the semiconductor with nanoapertures prepared by electron lithography. The PL emission from such nanoapertures shows individual PL lines corresponding to single quantum dots. By means of magneto-PL-spectroscopy the magnetic moment of single quantum dots of only some tens of Bohrmagnetons is addressed, including its thermal fluctuations. The temperature as well as magnetic field dependence of the exciton-Mn coupling is consistently described in the frame of a modified Brillouin model. 2) Ferromagnet-DMS-Hybrids A local manipulation of spins in a semiconductor can be realized by a preparation of ferromagnetic structures on the surface of a semiconductor. Magnetic fringe fields, emerging from nanostructured ferromagnets (FM) are capable of bending the spin bands of a buried quantum well on a mesoscopic length scale. This is especially valid for a semimagnetic quantum well like the ZnCdMnSe/ZnSe heterostructure used in the following experiments. Due to the drastic enhancement of the exciton g factor by the coupling to the Mn spins, huge spin splittings become possible. Magnetostatic calculations performed for ferromagnetic dysprosium (Dy) wire structures show, that fringe fields in the range of 0.1 to 1 T can be achieved in a perpendicular magnetization configuration. Magneto-PL measurements with a high spatial resolution actually demonstrate an influence of nanostructured ferromagnets on the excitonic spin bands in the quantum well and even provide some information about the magnetic characteristics of the FM nanoelements. 3) Single localization centers in a InGaN/GaN quantum well The localization of charge carriers in nm-sized islands has a strong influence on the optical properties of InGaN/GaN quantum wells. A detailed analysis of these effects require a reproduceable, spectroscopic access to single localization centers. This prerequisite has been fulfilled by depositing a mask with nanoapertures on the semiconductor surface. PL spectra measured on these nanoapertures at a temperature of 4 K reveal individual, spectrally narrow emission lines with a halfwidth down to 0.8 meV. Such a single PL line can be attributed to the emission from a single localization center. The optical access to single centers has been demonstrated here for the first time. As the following experiments showed, there is a profound difference between the behavior of such single PL lines and the inhomogenous PL signal from a large ensemble of centers. This gives a clear picture of the impact of some mechanisms relevant for the PL characteristics of InGaN quantum films, that have been the subject of a controversial debate. The most influential factors are the internal piezo electric field, the bandfilling effect and the formation of multiexcitons. KW - Cadmiumselenid KW - Zinkselenid KW - Manganselenide KW - Semimagnetischer Halbleiter KW - Quantenpunkt KW - Halbleiteroberfläche KW - Ferromagnetische Schicht KW - Nanostruktur KW - Spin KW - Indiumnitrid KW - Galliumnitrid KW - Ferromagnete KW - Photolumineszenz KW - Quantum dots KW - semimagnetic semiconductors KW - gallium nitride KW - ferromagnets KW - photoluminescence Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-15188 N1 - Aus datenschutzrechtlichen Gründen wurde der Zugriff auf den Volltext zu diesem Dokument gesperrt. Eine inhaltlich identische neue Version ist erhältlich unter: http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126558 ER - TY - THES A1 - Schöll, Achim T1 - High-resolution investigation of the electronic structure of organic thin films T1 - Hoch-aufgelöste Untersuchung der elektronischen Struktur organischer Dünnschichten N2 - Die vorliegende Arbeit befasst sich mit der elektronischen Struktur organischer Dünnfilme. Eine zentrale Frage dabei ist der Einfluss der Wechselwirkung zwischen den Molekülen in der kondensierten Phase und der Wechselwirkung an metall-organischen Grenzflächen auf die elektronischen Eigenschaften. Dazu wurden die experimentellen Methoden Photoelektronenspektroskopie (PES) und Röntgenabsorptionsspektroskopie (NEXAFS) mit höchster Energieauflösung angewandt. Zusätzlich wurden ab initio Rechnungen zur theoretischen Simulation von NEXAFS Spektren durchgeführt. Hauptsächlich wurden dünne, vakuumsublimierte Filme aromatischer Modellmoleküle mit sauerstoffhaltigen funktionellen Gruppen (NTCDA, PTCDA, NDCA, BPDCA und ANQ) auf Ag(111) Oberflächen untersucht. Die ausgewählten Moleküle besitzen wegen ihrer großen delokalisierten p-Elektronensysteme sehr interessante Eigenschaften für die Anwendung in elektronischen Bauelementen. Dank der hohen Energieauflösung von Synchrotronstrahlungsquellen der dritten Generation war es erstmals möglich, die Schwingungsfeinstruktur in den NEXAFS Spektren dieser kondensierten großen Moleküle sichtbar zu machen. Der Vergleich der Daten verschiedener Moleküle liefert dabei interessante Einblicke in den Kopplungmechanismus zwischen dem elektronischen Übergang und der Schwingungsanregung. Obwohl die Moleküle eine Vielzahl verschiedener Schwingungsmoden besitzen, kann man in deren NEXAFS Spektren beobachten, dass die elektronischen Übergänge jeweils an hauptsächlich eine Schwingungsmode koppeln. Die hochaufgelösten XPS Spektren der Moleküle NTCDA, PTCDA, NDCA, BPDCA und ANQ zeigen bestimmte systematische Unterschiede, so dass diese Spektren als Fingerabdruck für die jeweilige Substanz verwendet werden können. Durch die vergleichende Auswertung der Spektren konnten die 1s Bindungsenergien aller chemisch unterschiedlichen Kohlenstoff- und Sauerstoffatome bestimmt werden. Zusätzliche Strukturen in den Spektren können shake-up Satelliten zugeschrieben werden. Die fünf Moleküle stellen ein ideales Modellsystem dar, um fundamentale Aspekte der Rumpfelektronenspektroskopie zu untersuchen, wie Anfangs- und Endzustandseffekte und Satelliten, die durch die intramolekulare und intermolekulare Elektronendichteverteilung im Grund- und rumpfionisierten Zustand beeinflusst werden. Ein wichtiger Punkt dieser Dissertation sind spektroskopische Untersuchungen strukturell unterschiedlicher NTCDA Monolagenphasen auf Ag(111), deren Existenz aus vorangegangenen Arbeiten bekannt ist. Deutliche Unterschiede in der elektronischen Struktur der verschiedenen Phasen, die auf die Metall-Adsorbat Wechselwirkung zurückzuführen sind, konnten sowohl mittels XPS als auch mittels NEXAFS aufgezeigt werden. Sowohl für die komprimierte also auch für die relaxierte NTCDA Monolage kann die Bindung ans Substrat als schwach chemisorptiv charakterisiert werden, was eindeutig aus der Analyse der Satellitenstrukturen in den O 1s und C 1s XPS Spektren hervorgeht, die durch die dynamische Abschirmung durch Ladungstransfer vom Substrat erzeugt werden. Die NEXAFS Daten zeigen konsistent eine teilweise Besetzung des NTCDA LUMOs. Sowohl für die komprimierte als auch für die relaxierte NTCDA Monolage finden hochinteressante Phasenübergänge in ungeordnete Tieftemperaturphasen beim Abkühlen auf 160 K statt. Dabei wird die Adsorbat-Substrat Wechselwirkung stärker und das LUMO wird vollständig besetzt. Dies kann in den NEXAFS Spektren anhand des Verschwindens der zughörigen Übergänge beobachtet werden. Die XPS Spektren zeigen gleichzeitig eine deutliche Abnahme der Intensität schlecht abgeschirmter Photoemissionszustände, was auf die nun effektivere Ladungstransferabschirmung zurückzuführen ist. Für den Phasenübergang der relaxierten Monolage konnte mittels temperaturabhängiger NEXAFS Messungen eindeutig ein Hystereseverhalten gezeigt und die Hysteresekurve bestimmt werden. Die Hysterese beträgt etwa 20 K. Des weiteren wurde aus SPA-LEED Messungen die Aktivierungsenergie für den Phasenübergang der relaxierten Monolage beim Abkühlen auf ca. 60 meV bestimmt. Schließlich wurden NEXAFS Untersuchungen an Polyäthylenproben mit verschiedenem Komonomergehalt durchgeführt. Unterschiede in den Absorptionsspektren von Proben mit unterschiedlichem Komonomeranteil konnten eindeutig auf die unterschiedliche Kristallinität der Proben zurückgeführt werden, indem eine hochkristalline Probe in situ bis zur Schmelztemperatur geheizt wurde. Ab initio Rechnungen an einer Modelmatrix aus Butanmolekülen zeigen, dass die Spektren von kristallinem und amorphem Polyäthylen aufgrund der intermolekularen Wechselwirkung deutliche Unterschiede hauptsächlich für Resonanzen mit starkem Rydberg Charakter aufweisen. Damit lassen sich die Unterschiede in den Polyäthylenspektren durch die Überlagerung der Signaturen der kristallinen und amorphen Anteile erklären, die je nach Kristallinität der Probe in unterschiedlichen Verhältnissen vorliegen. N2 - This work is investigating the electronic structure of organic thin films. A central question in this respect is the influence of the interaction between the molecules in the condensed phase and the interaction at metal-organic interfaces on the electronic properties. For this purpose the experimental methods Photoelectron Spectroscopy (PES) and Near Edge X-ray Absorption Finestructure Spectroscopy (NEXAFS) were applied with highest energy resolution. In addition, ab initio calculations were performed for the theoretical simulation of NEXFAS spectra. The investigation is mainly focussing on thin, vacuum sublimated films of aromatic model molecules with oxygen-containing functional groups (NTCDA, PTCDA, NDCA, BPDCA and ANQ) and Ag(111) surfaces. Due to their large, delocalised p-systems these molecules have very interesting properties for their application in electronic devices. Due to the high energy resolution of third generation synchrotron sources the vibronic fine structure in the NEXAFS spectra of these large molecules could be resolved for the first time in the condensed phase. A comparison of the data of the different molecules provides interesting insight into the coupling between electronic transition and vibronic excitation. Although for these molecules a variety of different vibronic modes exist, the NEXAFS data show that preferentially only on mode couples to each electronic transition. The high-resolution PES spectra of the molecules NTCDA, PTCDA, NDCA, BPDCA and ANQ show distinct differences thus providing a fingerprint for each investigated substance. A comparative analysis of the spectra enabled us to define the 1s binding energies of all chemically different carbon and oxygen atoms. Additional structures in the spectra can be assigned as shake-up satellites. The five molecules are an ideal model system for the investigation of fundamental aspects of core electron spectroscopy, such as initial and final state effects and satellites, that are influenced by the intra- and intermolecular electron distribution in the ground and core ionized state. An important aspect in this thesis is the spectroscopic investigation of structurally different NTCDA monolayer phases on the Ag(111) surface. Marked differences in the electronic structures of the different phases, that can be assigned to differences in the metal-adsorbate interaction, could be demonstrated by XPS and NEXAFS. The substrate bonding can be characterized as chemisorptive for both, the compressed as well as the relaxed NTCDA monolayer, which can be unambiguously deduced from the analysis of satellite structures in the O 1s and C 1s XPS spectra. These satellites are due to dynamic screening by charge transfer from the substrate. The NEXAFS data show consistently, that the NTCDA LUMO becomes partly occupied upon adsorption. Highly interesting phase transitions into disordered low-temperature phases occur upon cooling to 160 K for both, the compressed and the relaxed NTCDA monolayer. Thereby, the adsorbate-substrate bonding is increased and the NTCDA LUMO becomes completely occupied. This can be observed in the NEXAFS data, where transitions involving LUMO final states are quenched. Simultaneously, the XPS data show a distinctly decreased intensity of unscreened photoemission states due to enhanced charge transfer screening. In addition, a hysteresis behaviour could be demonstrated for the phase transition of the relaxed monolayer by temperature dependent NEXAFS experiments and the hysteresis curve was determined. The hysteresis could be quantified to approx. 20 K. From SPA-LEED experiments the activating energy for the phase transition of the relaxed monolayer upon cooling could be determined to 60 meV. Finally, a NEXAFS investigation of polyethylene samples with different comonomer content is presented. Differences in the absorption spectra between samples with different comonomer content could be unambiguously assigned to the different crystallinities of the samples by heating a highly crystalline sample in situ close to the melting temperature. Ab initio calculations on a model matrix of butane molecules show, that the spectra of crystalline and amorphous polyethylene differ distinctly due to the intermolecular interaction, which can be observed best for resonances with strong Rydberg character. Thus, the differences in the PE spectra can be explained by the superposition of the signatures of crystalline and amorphous moieties, that are mixed according to the respective crystallinity. KW - Dünne Schicht KW - Organische Verbindungen KW - Elektronenstruktur KW - Organische Dünnschichten KW - elektronische Struktur KW - NEXAFS KW - XPS KW - Spektroskopie KW - organic thin films KW - electronic structure KW - NEXAFS KW - XPS KW - spectroscopy Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-10809 ER - TY - THES A1 - Schäfer, David T1 - Entwicklung eines Transmissionsmikroskops für weiche Röntgenstrahlung und die Anwendung an Laborquellen T1 - Table-Top Transmission Soft X-ray Microscope for laboratory applications N2 - Die vorliegende Arbeit befasst sich mit der Entwicklung und Konstruktion eines mobilen Transmissionsmikroskops für weiche Röntgenstrahlung. Dieses ist speziell für den Einsatz an Laborquellen konzipiert und erlaubt durch einen modularen Aufbau auch den Betrieb an Synchrotroneinrichtungen. Das Mikroskop basiert auf einem abbildenden System mit einer Zonenplatte als Objektiv und einer CCD-Kamera als Detektor. Das Anwendungsgebiet erstreckt sich über den spektralen Bereich des Wasserfensters zwischen 2,3 nm und 4,4 nm Wellenlänge bis hin zu extrem ultravioletter Strahlung (Wellenlänge < 20 nm). Dabei können vakuumtaugliche Proben, wie beispielsweise lithographische Testobjekte, Kieselalgen oder chemisch fixierte biologische Zellen untersucht werden. Bei den verwendeten Laborquellen handelt es sich zum einen um ein laserinduziertes Plasma mit einem flüssigen Stickstoffstrahl als Target und zum anderen um eine elektrische Stickstoffgas-Entladungsquelle mit Hohlkathoden-Elektrodengeometrie. Aufgrund der stark unterschiedlichen Quellkonzepte müssen die Quellen für die Entwicklung entsprechender Kondensorkonzepte in Bezug auf ihre spektrale Strahldichte und Brillanz charakterisiert werden. Daher wurden neben Messungen mit einem absolut kalibrierten Spektrographen auch die Quellgrößen und Linienbreiten der wasserstoff- und heliumähnlichen Emissionslinien von Stickstoff bei N-Ly-alpha = 2,48 nm und N-He-alpha = 2,88 nm untersucht. Für eine gute Bildqualität sind neben einer gleichmäßigen, monochromatischen Ausleuchtung die Intensität in der Objektebene und eine Anpassung der numerischen Apertur von Kondensor und abbildender Optik wichtige Parameter. Daher wird an der laserinduzierten Plasmaquelle eine Zonenplatte als Kondensor verwendet. Diese bildet die Quelle 1:1 in die Objektebene ab und wirkt gleichzeitig als Linearmonochromator. Aufgrund der wellenlängenabhängigen Brennweite bietet sie zudem die Möglichkeit Spektromikroskopie zu betreiben. Da die emittierende Quellfläche der Entladungsquelle etwa vier Größenordnungen größer ist als die der laserinduzierten Plasmaquelle, wird an der Entladungsquelle ein mit Gold bedampfter, rotationssymmetrischer Ellipsoid für die Objektbeleuchtung verwendet. Angesichts einer geringeren Plasmatemperatur der Entladungsquelle und der damit verbundenen schwachen Emission der wasserstoffähnlichen Linien kann die He-alpha-Linie mit Hilfe eines Titan-Filters freigestellt werden. Anhand von Testobjekten und biologischen Proben wurde die Leistungsfähigkeit der beiden Konzepte gegenübergestellt. Während die räumliche Auflösung nach dem Rayleigh-Kriterium an der laserinduzierten Plasmaquelle durch Vibrationen im Aufbau auf ca. 70 nm begrenzt ist, konnte an der elektrischen Entladungsquelle eine nahezu beugungsbegrenzte Auflösung von 40 nm nachgewiesen werden. Die Belichtungszeiten bei 1000-facher Vergrößerung liegen bei der laserinduzierten Quelle je nach Objekt zwischen 10 und 30 Minuten. Durch die zehnfach höhere Intensität in der Objektebene ist die Belichtungszeit an der elektrischen Entladungsquelle entsprechend kürzer. Neben diesen Ergebnissen wird ein neues Anwendungsgebiet im Bereich organischer Halbleiter vorgestellt und erste Experimente präsentiert. N2 - The presented work deals with the development and construction of a portable soft X-ray transmission microscope. It is specially designed for applications at laboratory sources but can also be operated at synchrotron facilities due to its modular layout. The microscope is based on a zone plate imaging system in conjunction with a CCD-camera as detector. The field of application ranges from the water-window spectral region between 2.3 nm and 4.4 nm wavelength to the extreme ultraviolet (wavelength < 20 nm). Vacuum prepared samples like lithographical test objects, diatoms or chemically fixed biological cells can be investigated. Two laboratory sources, a laser induced plasma based on a liquid nitrogen jet target and an electrical discharge source using hollow cathode electrode geometry, have been utilized. Due to the highly different source concepts the sources had to be characterized with regard to the radiant intensity and brilliance in order to determine an adequate condenser system. Therefore, beside measurements with an absolute calibrated spectrograph, the source sizes and line widths of the hydrogen- and helium-like emission lines of nitrogen at N-Ly-alpha = 2,48 nm and N-He-alpha = 2,88 nm have been investigated. For good image quality, parameters like uniform and monochromatic illumination of the object with high intensity and matched numerical aperture of condenser and imaging optics are important parameters. Therefore a zone plate is used as condenser at the laser induced plasma source. The zone plate images the source into the object plane and also acts as a linear monochromator. Due to the wavelength depending focal length of the zone plate the setup features spectral imaging capabilities. Since the emitting source area of the electrical discharge is about four orders of magnitude larger than the source size of the laser induced plasma, a gold-coated axially symmetric ellipsoid is used for object illumination at the discharge source. With respect to the lower plasma temperature of the discharge source and closely related weak emission of hydrogen like emission lines, the He-emission line can be selected by applying a titanium filter. The performance of both concepts is presented by imaging of test objects and biological cells. Whereas the spatial Rayleigh-resolution at the laser induced plasma source is limited to 70 nm due to vibrations, a nearly diffraction limited resolution of 40 nm can be demonstrated at the electrical discharge source. The exposure time at the laser induced plasma source at a magnification of 1000 depends on the object and ranges from 10 to 30 minutes. Due to a 10-times higher intensity in the object plane at the electrical discharge source the exposure time at this source is proportionate shorter. Besides performance tests a new field of application in organic semiconductors is described and first experiments are presented. KW - Röntgenmikroskop KW - Weiche Röntgenstrahlung KW - Transmission KW - Wasserfenster KW - Labormikroskopie KW - Transmissionsmikroskopie KW - Fresnel-Zonenplatte KW - Lasererzeugtes Plasma KW - Elektrische Entladung KW - Table-top KW - soft x-ray KW - transmission microscopy KW - zone plate KW - water window Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-54383 ER - TY - THES A1 - Schwertberger, Ruth T1 - Epitaxie von InAs-Quanten-Dash-Strukturen auf InP und ihre Anwendung in Telekommunikationslasern T1 - Epitaxy of InAs quantum dash structures on InP and their application in telecommunication lasers N2 - Die vorliegende Arbeit beschäftigt sich mit der Herstellung und Charakterisierung von niedrigdimensionalen Strukturen für den Einsatz als aktive Schicht in InP-Halbleiterlasern. Quantenpunktstrukturen als Lasermedium weisen gegenüber herkömmlichen Quantenfilmlasern einige Vorteile auf, wie beispielsweise geringe Schwellenstromdichten, breites Verstärkungsspektrum und geringe Temperatursensitivität der Emissionswellenlänge. Ziel dieser Arbeit ist es, diese speziellen Vorteile, die im GaAs-System größtenteils nachgewiesen sind, auch auf das InP-System zu übertragen, da dieses für die Telekommunikationswellenlänge 1.55 µm prädestiniert ist. Die vorgestellten Strukturen wurden mittels einer Gasquellen-Molekularstrahlepitaxie-Anlage unter Verwendung der alternativen Gruppe-V-Precursor Tertiärbutylphosphin (TBP) und -arsin (TBA) hergestellt. Die Bildung der Quantenpunktstrukturen wurde zunächst an Hand von Teststrukturen optimiert. Scheidet man InAs auf einem InP(100)-Substrat ab, so bilden sich – anders als auf GaAs – keine runden InAs-Quantenpunkte, sondern unregelmäßige, strichförmige Strukturen mit einer klaren Vorzugsorientierung, sogenannte Dashes. Verschiedene Wachstumsparameter, wie die Menge an deponiertem InAs, der Strukturaufbau oder der Wachstumsmodus, lassen eine Beeinflussung der Emissionseigenschaften zu, die mittels Photolumineszenz (PL)-Spektroskopie untersucht wurden. So kann die Emissionswellenlänge der Dashes sehr genau und über einen großen Bereich zwischen 1.2 und 2.0 µm über die nominelle Dicke der Dash-Schicht festgelegt werden. Dieser Zusammenhang lässt sich auch nutzen, um durch die Kombination von Schichten unterschiedlicher Dash-Größe eine extreme Verbreiterung des Verstärkungsspektrums auf über 300 nm zu erzielen. Neben der Hauptanwendung als Telekommunikationslaser sind auch Einsatzmöglichkeiten in der Gassensorik für einen Wellenlängenbereich zwischen 1.8 und 2.0 µm denkbar. Dieser ist neben der Verwendung extrem dicker Schichten durch das Prinzip des migrationsunterstützten Wachstums (engl. migration enhanced epitaxy) oder durch die Einbettung der Dash-Schichten in einen InGaAs-Quantenfilm ("Dash-in-a-Well"-Struktur) realisierbar. Letzteres zieht eine starke Rotverschiebung um etwa 130 meV bei gleichzeitiger schmaler und intensiver Emission nach sich. Da die Dashes einige sehr interessante Eigenschaften aufweisen, wurde ihre Eignung als aktive Schicht eines InP-Halbleiterlasers untersucht. Zunächst wurden der genaue Schichtaufbau, speziell die Fernfeldcharakteristik, und die Wachstumsparameter optimiert. Ebenso wurde der Effekt eines nachträglichen Ausheilschritts diskutiert. Da die speziellen Vorteile der Quanten-Dash(QD)-Strukturen nur Relevanz haben, wenn auch ihre Grunddaten einem Quantenfilmlaser (QW-Laser) auf InP ebenbürtig sind, wurde besonderer Wert auf einen entsprechenden Vergleich gelegt. Dabei zeigt sich, dass die Effizienzen ebenso wie die Absorption der QD-Laser nahezu identisch mit QW-Lasern sind. Die Schwellenstromdichten weisen eine stärkere Abhängigkeit von der Länge des Laserresonators auf, was dazu führt, dass ab einer Länge von 1.2 mm QD-Laser geringere Werte zeigen. Die Temperaturabhängigkeit der Schwellenstromdichte, die sich in der charakteristischen Temperatur T0 äussert, zeigt dagegen für QD-Laser eine stärkere Sensitivität mit maximalen T0-Werten von knapp über 100 K. Betrachtet man das Emissionsspektrum der QD-Laser, so fällt die starke Blauverschiebung mit abnehmender Bauteillänge auf. Gleichzeitig zeigen diese Laser im Vergleich zu QW-Lasern eine deutlich größere Temperaturstabilität der Emissionswellenlänge. Beide Eigenschaften haben ihre Ursache in der flachen Form des Verstärkungsspektrums. Zusätzlich wurden einige der an Hand der Teststrukturen gezeigten Dash-Eigenschaften auch an Laserstrukturen nachgewiesen. So lässt sich durch Variation der Dash-Schichtdicke von 5 auf 7.5 ML eine Verschiebung der Emissionswellenlänge um bis zu 230 nm realisieren, wobei dieses Verfahren damit noch nicht ausgereizt ist. Ebenso wurde auch ein Überlapp aus sechs jeweils verschieden dicken Dash-Schichten in eine Laserstruktur eingebaut. An Hand von Subschwellspektren wurde eine Verstärkungsbreite von etwa 220 nm nachgewiesen, die eine Abdeckung des gesamten Telekommunikationsbandes durch eine einzige Laserstruktur erlauben würde. Aus Quanten-Dash-Material prozessierte Stegwellenleiter (RWG)-Laser weisen sehr vielversprechende Daten mit hohen Ausgangsleistungen bis 15 mW pro Facette und niedrigen Schwellenströmen auf. Damit schafft diese Arbeit die Grundvoraussetzungen, um InAs-Quanten-Dashes als echte Alternative zu herkömmlichen Quantenfilmen in InP-Halbleiterlasern zu etablieren. Besonders das breite Verstärkungsspektrum und die hohe Temperaturstabilität der Emissionswellenlänge zeichnen dieses Material aus. N2 - In this work the fabrication and characterisation of low-dimensional structures that can be used as active regions in InP semiconductor lasers are presented. Compared to conventional quantum well lasers quantum dot material shows some advantages like low threshold current density, broad gain spectrum and low temperature sensitivity of the emission wavelength. Most of these special advantages have already been demonstrated in the GaAs system and should be transferred to the InP system which is the material of choice for the telecommunication wavelength 1.55 µm. The presented structures were grown in a gas source molecular beam epitaxy system using the alternative group-V-precursors tertiarybutylphosphine (TBP) and tertiarybutylarsine (TBA). In a first step the formation of the quantum dot-like structures was optimised in test samples. When InAs is deposited on an InP(100) substrate unlike on GaAs there are no circular InAs quantum dots formed, but irregular dash-like structures with a preferred orientation. Growth parameters like the amount of InAs deposited, the design of the structure or the growth mode allow an influence on the emission properties which were investigated by photoluminescence (PL) spectroscopy. Thus the emission wavelength of the dashes can be defined very accurately over a large region between 1.2 and 2.0 µm by varying the thickness of the dash layer. This dependence can be used to achieve an extreme broadening of the gain spectrum of over 300 nm by overlapping layers with different thicknesses. Beside the major application in telecommunication lasers the usage for gas sensing detectors in the wavelength range between 1.8 and 2.0 µm is also possible. In addition to the employment of extremely thick dash layers this region can be reached by the growth principle of migration enhanced epitaxy or by embedding the dash layers in an InGaAs quantum well in a so-called DWell structure. The latter involves a large red-shift of about 130 meV accompanied by a small and intense emission. With the dashes showing a very interesting behaviour their suitability as an active layer of an InP semiconductor laser needs to be investigated. The exact layer design, especially the farfield characteristic, and the growth parameters had to be optimised. Also the effect of a subsequent annealing step was discussed. As the special advantages of quantum dash (QD) lasers are only of importance if their basic data are comparable to a quantum well (QW) laser on InP much attention was paid to a corresponding comparison. It can be shown that the efficiencies and the absorption of the QD lasers are nearly similar to QW lasers. The threshold current densities have a stronger dependence on the resonator length resulting in lower values for quantum dash lasers above 1.2 mm cavity length. The temperature dependence of the threshold current density corresponding to the characteristic temperature T0 shows a stronger sensitivity for QD lasers with maximum T0 values of about 100 K. In the emission spectra of the dash lasers a strong blue-shift with decreasing device length is recognised. At the same time these lasers have a much larger temperature stability of the emission wavelength. Both effects have their reason in the smaller slope of the gain spectrum. Some of the dash properties shown for test structures were also demonstrated for laser structures. By varying the thickness of the dash layers from 5 to 7.5 MLs a shift of the emission wavelength of about 230 nm was realised bearing potential for an even further extension of this method. Also a stack of six dash layers all slightly different in thickness was embedded in a laser structure. Using subthreshold spectra a gain width of 220 nm was measured giving the opportunity to cover the whole telecommunication band with a single device. Ridge waveguide lasers processed from quantum dash material show promising results with high maximum output powers of up to 15 mW per facet and low threshold currents. This work creates the basis for establishing InAs quantum dash lasers as an alternative for conventional quantum well lasers in the InP system. Especially the broad gain spectrum and the high temperature stability of the emission wavelength distinguish this material. KW - Halbleiterlaser KW - Indiumphosphid KW - Indiumarsenid KW - Nanostruktur KW - Molekularstrahlepitaxie KW - Optoelektronik KW - Halbleiterlaser KW - Epitaxie KW - Quanten-Dash KW - InP KW - optoelectronics KW - semiconductor laser KW - epitaxy KW - quantum dash KW - InP Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-14609 ER - TY - THES A1 - Schwedhelm, Kai Florian T1 - Optimierte Methoden der Magnetresonanz-Spektroskopie zur molekularen Charakterisierung neuartiger Wirkstoffe gegen Infektionskrankheiten T1 - Optimized methods in nuclear magnetic resonance spectroscopy for charakterization of novell agents against infectious diseases N2 - In diesem Projekt wurde die Wechselwirkung des PPIase-Enzyms MIP mit Kollagen IV unter- sucht. MIP ist maßgeblich für die Infektiösität von Legionella pneumophila verantwortlich, einem Bakterium, welches im Menschen schwere Lungenentzündungen auslösen kann. Das Enzym zeigt eine hohe Affinität gegenüber einem kurzen Peptidsequenzabschnitt in Kolla- gen IV (genannt „P290”), welches unter anderem im Epithel der Lunge zu finden ist. Die Interaktionsoberfläche der Moleküle wurde durch den Einsatz eines paramagnetischen Spin-Labels in NMR-Experimenten charakterisiert. Mit Hilfe von Docking und Moleküldy- namiksimulationen konnte aus diesen Daten ein Modell des MIP-Kollagen-Komplexes be- rechnet werden. Es wurde gezeigt, dass MIP als Dimer in der Lage ist, nach Kollagen IV zu „greifen” und sich dann an das Molekül heranzuziehen. Wahrscheinlich dient dieser Mechanismus der Adhä- sion von L. pneumophila an die Wirtszelle. Neben der zuvor postulierten Destabilisierung von Kollagen IV durch MIP, welche hier nicht beobachtet wurde, könnte die Adhäsion ein wichtiger Faktor für die Virulenz von L. pneumophila sein. Weiterhin wurde die inhibitorische Wirkung des isolierten Peptids P290 auf die biologische PPIase-Aktivität von MIP untersucht. Durch NMR-Messungen und anschließenden Mole- küldynamiksimulationen konnte gezeigt werden, dass P290 sich stabil in die Bindungsta- sche von MIP einlagert und durch den Sequenzabschnitt -CYS130-PRO131---TRP134- das Enzym blockiert. Die übrigen Aminosäuren in P290 dienen der Stabilisierung des Kom- plexes und sorgen für die Selektivität von P290, welches, im Unterschied zu bekannten Wirkstoffen, das humane Homolog zu MIP nicht inhibiert. Die Vorhersagen der Simulatio- nen konnten durch ein Peptid Microarray und Messungen der enzymatischen Aktivität von MIP in PPIase-Assays bestätigt werden. Die Ergebnisse wurden zur Optimierung von P290 eingesetzt, indem die Peptidsequenz durch den Austausch zweier Aminosäuren verändert und das Molekül zu einem Ring geschlossen wurde. Die entstandene Struktur besitzt deut- lich verbesserte Bindungseigenschaften und könnte künftig als Basis für eine neue Klasse von Wirkstoffen gegen L. pneumophila dienen. In diesem Projekt wurde eine Methode zur Aufklärung der Molekülstruktur neuartiger Wirkstoffe gegen Malaria im Komplex mit ihrem paramagnetischen Zielmolekül etabliert und weiterentwickelt. Die Vorgehensweise leitet intermolekulare Distanzinformationen aus der sog. paramagnetischen Relaxation ab, einem Effekt, der den Einsatz klassischer Me- thoden zur Molekülstrukturaufklärung mittels NMR verhindert. Es werden drei Parameter durch NMR-Spektroskopie bestimmt: 1. die longitudinale Relaxationszeit der Wasserstoff- atome in Wirkstoffmolekül, 2. die effektive Korrelationszeit des Komplexes und 3. der Spin- Zustand des Eisenions im Zielmolekül. Mit Hilfe dieser Messmethode konnte die Komplexstruktur mehrerer bekannter Medika- mente gegen Malaria aufgeklärt werden. Weiterhin wurden zwei neue Klassen von Wirkstof- fen untersucht, die C,C-gekoppelten Naphthylisoquinolin-Alkaloide und die N,C-gekoppelte Naphthylisoquinolin-Alkaloide. In Übereinstimmung mit theoretischen Vorhersagen aus der Literatur lagern sich die Wirkstoffe stets um einen Winkel geneigt und in Richtung des Randes des Zielmoleküls verschoben an. Diese Konfiguration maximiert die attraktiven π- π-Wechselwirkungen zwischen den Molekülen. Aufgrund der gewonnenen Ergebnisse aus NMR, UV-Spektroskopie und Massenspektrome- trie konnte die Existenz eines bisher nicht bekannten Tetramer-Komplexes nachgewiesen werden, welcher eine wichtige Zwischenstufe in der Biokristallisation von Hämozoin durch die Malariaparasiten darstellen könnte, und Ansatzpunkte für den weiterhin nicht vollstän- dig bekannten Wirkmechanismus der meisten Antimalaria-Wirkstoffe liefert. Für die Naphthylisoquinolin-Alkaloide zeigte sich weiterhin, dass Wasser eine essenzielle Rolle in der Komplexbildung spielt. In Moleküldynamiksimulationen der N,C-gekoppelten Naphthylisoquinolin-Alkaloide konnte die Entstehung einer Wasserstoffbrücke zwischen Wirkstoff und Zielmolekül gezeigt werden, welche einen zusätzlichen Weg der Komplex- stabilisierung neben den bereits bekannten π-π-Wechselwirkungen aufzeigt. Die N,C-NIQs konnten erstmals auch bei einem pH-Wert von 5,6 beobachtet werden, einer chemischen Umgebung wie sie auch in-vivo in der Verdauungsvakuole des Malariaparasiten herrscht. N2 - Summary Even in the 21st century, infectious diseases remain the predominant cause of death world- wide. According to reports of the World Health Organisation, 2 million people die of Malaria every year, most of which are children under the age of five years. Respiratory infections claim an additional 3.9 million lives. Other infections are held responsible for a total of more than 10 million deaths. Global climate change leads to the occurrence of tropical in- fections well beyond their former endemic regions. Additional challenges arise due to the growing number of resistant organisms, rendering most known treatments ineffective. To achieve sustained success in the fight against infectious diseases, a detailed understan- ding on the mode of action of newly developed substances on a molecular level is essential. In this thesis, magnetic resonance spectroscopy is used as a tool for molecular structure determination. My results may offer incentives for the development of new agents against infectious diseases and their continuous optimization. 4.1 The MIP-collagen IV complex The scope of this project was to investigate the interaction between the PPIase enzyme MIP and the NC1 (non-collagenous 1) domain of collagen IV. The MIP (macrophage infectivity potentiator) protein is the major virulence factor of Legionella pneumophila, a bacterium causing severe lung infections in humans. MIP exhibits high affinity towards a short peptide sequence in collagen IV (“P290”). Amongst others, this type of collagen is found in the epithelial cells of the lung. In this work, the interface of interaction between P290 and MIP was mapped using a pa- ramagnetic spin label in combination with nuclear magnetic resonance spectroscopy expe- riments. Labeled P290 strongly enhances the relaxation rates of individual amino acids in MIP, which are in the immediate vicinity (within 1 nm) of the spin label. The enhancedrelaxation rates were detected through T2-sensitive HSQC experiments. Subsequently, re- sults were incorporated in docking and molecular dynamic (MD) simulations to compute a model of the MIP-collagen IV complex. Results show the MIP dimer “grabbing” collagen IV with both enzymatic domains and pul- ling the molecules closer together. We suggest that this molecular adhesion mechanism may play a key role in the invasion of host tissue by L. pneumophila. A possible destabilization of collagen IV through the enzymatic activity of MIP, as suggested previously by other groups, was not observed. Additionally, our co-operation partners were able to demonstrate that P290, as an indi- vidual peptide, inhibits the biological PPIase activity of MIP, while leaving human homo- logue enzymes untouched. My findings from NMR measurements and subsequent MD si- mulations showed that P290 occupies the MIP binding pocket via the amino acid sequence -CYS130-PRO131---TRP134-. This sequence element is stabilized via the attachment of the terminal residues of P290 to the surface of MIP, thereby enabling P290 to distinguish between MIP and human enzymes. Based on these results, we constructed optimized versions of P290 by ring closure and repla- cement of two amino acids. Our co-operation partners showed that the resulting structures exhibit improved binding properties on a peptide microarray and may provide the basis for a new class of inhibitors targeting Legionella pneumophila. 4.2 Structure elucidation of paramagnetic complexes for- med by novel antimalarial agents We used paramagnetic NMR spectroscopy to characterize the formation of complexes of several antimalarial compounds with their presumed target “heme”. A paramagnetic Fe(III) ion is located at the center of heme, which influences the longitudinal relaxation rates of nearby proton spins. This effect interferes with common strategies for NMR structure elucidation, but in this study was taken advantage of in a newly developed method to map intermolecular distances with high precision using NMR inversion recovery experiments at 9.4 T, 14.1 T, 17.6 T, and 18.8 T. This method was utilized to solve the molecular structure of known drugs against Mala- ria as well as two new classes of antimalarial agents (the C,C-coupled naphthylisoquinoline alkaloids and the N,C-coupled naphthylisoquinoline alkaloids) in complex with their target molecule: heme. In accordance with theoretical predictions from the literature, we sho- wed that the drug molecules align in a configuration maximizing attractive π-π stacking interactions between the molecules. In combination with findings from NMR, UV spectroscopy and mass spectrometry, we de- monstrated the formation of a previously unknown tetrameric complex. This complex may represent an important step in the mode of action of antimalarial drugs. Additionally, results from NMR measurements and molecular dynamics simulations provided insight into the important role of H2O for complex stabilization. We were able to demonstrate the formation of a so far undescribed hydrogen bond between drug and target. Furthermore, it was possible to investigate the N,C-coupled naphthylisoquinoline alkaloids at pH 5.6, which exactly matches the chemical environment in the food vacuole of the ma- larial parasite in-vivo. All these findings may contribute to a deeper understanding of the mode of action of new antimalarial agents. KW - NMR-Spektroskopie KW - Legionella pneumophila KW - Legionellen KW - Legionärskrankheit KW - Würzburg / Sonderforschungsbereich Erkennung KW - NMR KW - Malaria KW - Legionella KW - paramagnetic resonance KW - spin label Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-38535 ER - TY - THES A1 - Schwarz, Christoph Benjamin T1 - Full vector-field control of femtosecond laser pulses with an improved optical design T1 - Vollständige Kontrolle des Vektorfelds von Femtosekunden-Laserpulsen mit einem verbesserten optischen Design N2 - The controlled shaping of ultrashort laser pulses is a powerful technology and applied in many laser laboratories today. Most of the used pulse shapers are only able to produce linearly polarized pulses shaped in amplitude and phase. Some devices are also capable of producing limited time-varying polarization profiles, but they are not able to control the amplitude. However, for some state-of-the-art non-linear time-resolved methods, such as polarization-enhanced two-dimensional spectroscopy, the possibility of controlling the amplitude and the polarization simultaneously is desirable. Over the last years, different concepts have been developed to overcome these restrictions and to manipulate the complete vector-field of an ultrashort laser pulse with independent control over all four degrees of freedom - phase, amplitude, orientation, and ellipticity. The aim of this work was to build such a vector-field shaper. While the basic concept used for our setup is based on previous designs reported in the literature, the goal was to develop an optimized optical design that minimizes artifacts, allowing for the generation of predefined polarization pulse sequences with the highest achievable accuracy. In Chapter 3, different approaches reported in the literature for extended and unrestricted vector-field control were examined and compared in detail. Based on this analysis, we decided to follow the approach of modulating the spectral phase and amplitude of two perpendicularly polarized pulses independently from each other in two arms of an interferometer and recombining them to a single laser pulse to gain control over the complete vector field. As described in Chapter 4, the setup consists of three functional groups: i) an optical component to generate and recombine the two polarized beams, ii) a 4f setup, and iii) a refracting telescope to direct the two beams under two different angles of incidence onto the grating of the 4f setup in a common-path geometry. This geometry was chosen to overcome potential phase instabilities of an interferometric vector-field shaper. Manipulating the two perpendicularly polarized pulses simultaneously within one 4f setup and using adjacent pixel groups of the same liquid-crystal spatial light modulator (LC SLM) for the two polarizations has the advantages that only a single dual-layer LC SLM is required and that a robust and compact setup was achieved. The shaping capabilities of the presented design were optimized by finding the best parameters for the setup through numerical calculations to adjust the frequency distributions for a broad spectrum of 740 – 880 nm. Instead of using a Wollaston prism as in previous designs, a thin-film polarizer (TFP) is utilized to generate and recombine the two orthogonally polarized beams. Artifacts such as angular dispersion and phase distortions along the beam profile which arise when a Wollaston prism is used were discussed. Furthermore, it was shown by ray-tracing simulations that in combination with a telescope and the 4f setup, a significant deformation of the beam profile would be present when using a Wollaston prism since a separation of the incoming and outgoing beam in height is needed. The ray-tracing simulations also showed that most optical aberrations of the setup are canceled out when the incoming and outgoing beams propagate in the exact same plane by inverting the beam paths. This was realized by employing a TFP in the so-called crossed-polarizer arrangement which has also the advantage that the polarization-dependent efficiencies of the TFP and the other optics are automatically compensated and that a high extinction ratio in the order of 15000:1 is reached. Chromatic aberrations are, however, not compensated by the crossed-polarizer arrangement. The ray-tracing simulations confirmed that these chromatic aberrations are mainly caused by the telescope and not by the cylindrical lens of the 4f setup. Nevertheless, in the experimentally used wavelength range of 780 – 816 nm, only minor distortions of the beam profile were observed, which were thus considered to be negligible in the presented setup. The software implementation of the pulse shaper was reviewed in Chapter 5 of this thesis. In order to perform various experiments, five different parameterizations, accounting for the extended shaping capabilities of a vector-field shaper, were developed. The Pixel Basis, the Spectral Basis, and the Spectral Taylor Basis can generally be used in combination with an optimization algorithm and are therefore well suited for quantum control experiments. For multidimensional spectroscopy, the Polarized Four-Pulse Basis was established. With this parameterization pulse sequences with up to four subpulses can be created. The polarization state of each subpulse can be specified and the relative intensity, phase, and temporal delay between consecutive subpulses can be controlled. In addition, different software programs were introduced in Chapter 5 which are required to perform the experiments conducted in this work. The experimental results were presented in Chapter 6. The frequency distribution across the LC SLM was measured proving that the optimal frequency distribution was realized experimentally. Furthermore, the excellent performance of the TFP was verified. In general, satellite pulses are emitted from the TFP due to multiple internal reflections. Various measurements demonstrated that these pulses are temporally separated by at least 4.05 ps from the main pulse and that they have vanishing intensity. The phase stability between the two arms of the presented common-path setup σ = 28.3 mrad (λ/222) over 60 minutes. To further improve this stability over very long measurement times, an on-the-fly phase reduction and stabilization (OPRAS) routine utilizing the pulse shaper itself was developed. This routine automatically produces a compressed pulse with a minimized relative phase between the two polarization components. A phase stability of σ = 31.9 mrad (λ/197) over nearly 24 hours was measured by employing OPRAS. Various pulse sequences exceeding the capabilities of conventional pulse shapers were generated and characterized. The experimental results proved that shaped pulses with arbitrary phase, amplitude, and polarization states can be created. In all cases very high agreement between the target parameters and the experimental data was achieved. For the future use of the setup also possible modifications were suggested. These are not strictly required, but all of them could further improve the performance and flexibility of the setup. Firstly, it was illustrated how a “dual-output” of the setup can be realized. With this modification it would be possible to use the main intensity of the shaped pulse for an experiment while using a small fraction to characterize the pulse or to perform OPRAS simultaneously. Secondly, the basic idea of replacing the telescope by focusing mirrors in order to eliminate the chromatic aberrations was presented. Regarding the different parameterizations for vector-field shaping, some modifications increasing the flexibility of the implemented bases and the realization of a von Neumann Basis for the presented setup were proposed. In future experiments, the vector-field shaper will be used in conjunction with a photoemission electron microscope (PEEM). This approach combines the temporal resolution provided by ultrashort laser pulses with the high spatial resolution gained by electron microscopy in order to perform two-dimensional spectroscopy and coherent control on nanostructures with polarization-shaped femtosecond laser pulses. In combination with other chiral-sensitive experimental setups implemented earlier in our group, the vector-field shaper opens up new perspectives for chiral femtochemistry and chiral control. The designed vector-field shaper meets all requirements to generate high-precision polarization-shaped multipulse sequences. These can be used to perform numerous polarization-sensitive experiments. Employing the OPRAS routine, a quasi-infinitely long phase stability is achieved and complex and elaborated long-term measurements can be carried out. The fact that OPRAS demands no additional hardware and that only a single dual-layer LC SLM and inexpensive optics are required allows the building of a vector-field shaper at comparatively low costs. We hope that with the detailed insights into the optical design process as well as into the software implementation given in this thesis, vector-field shaping will become a standard technique just as conventional pulse shaping in the upcoming years. N2 - Die gezielte Formung ultrakurzer Laserpulse ist eine leistungsstarke Technik, die heutzutage in vielen Laserlaboren eingesetzt wird. Die meisten Pulsformer können jedoch nur linear polarisierte, in Phase und Amplitude geformte Laserpulse erzeugen. Einige Pulsformer können auch sich zeitlich verändernde Polarisationszustände generieren. Die möglichen Polarisationszustände sind allerdings beschränkt und eine gleichzeitige Formung der Amplitude ist dann nicht mehr möglich. Für einige moderne, nicht-lineare, zeitaufgelöste, spektroskopische Methoden, wie z.B. die polarisationsunterstützte zweidimensionale Spektroskopie, ist aber die gleichzeitige Kontrolle über die Polarisation und die Amplitude erstrebenswert. In den letzten Jahren wurden verschiedene Konzepte entwickelt, um diese Beschränkungen zu überwinden und eine vollständige Kontrolle des Vektorfeldes über die vier Freiheitsgrade Phase, Amplitude, Orientierung und Elliptizität eines ultrakurzen Laserpulses zu erlangen. Ziel dieser Arbeit war es, einen solchen Vektorfeldformer zu konstruieren. Die Grundidee für das Design unseres Aufbaus basiert auf verschiedenen literaturbekannten Konzepten. Unser Ziel war es jedoch, ein optimiertes Design zu entwickeln, bei dem Formungsartefakte minimal sind und definierte polarisationsgeformte Mehrfachpulse mit der höchstmöglichen Genauigkeit erzeugt werden können. In Kapitel 3 wurden verschiedene vorherige Ansätze für die erweiterte und vollständige Vektorfeldkontrolle detailliert geprüft und verglichen. Basierend auf dieser Analyse haben wir uns dazu entschlossen, das Konzept eines interferometrischen Vektorfeldformers zu verwenden. Bei diesem werden die spektrale Phase und Amplitude zweier orthogonal polarisierter Pulse unabhängig voneinander in den zwei Armen eines Interferometers manipuliert und durch Überlagerung dieser zwei Pulse die vollständige Kontrolle über das Vektorfeld erlangt. Wie in Kapitel 4 beschrieben, besteht der Aufbau aus drei funktionellen Gruppen: i) einer optischen Komponente, um die zwei polarisierten Strahlen zu erzeugen und zu rekombinieren, ii) einem sog. 4f-Aufbau und iii) einem Linsenteleskop, um die zwei Strahlen unter unterschiedlichen Winkeln auf das Gitter des 4f-Aufbaus zu lenken, so dass beide Strahlen über dieselben Optiken propagieren. Diese Art der Strahlführung wurde gewählt, um die interferometrische Stabilität des Aufbaus zu verbessern. Beide Strahlen werden mit demselben 4f-Aufbau geformt, indem unterschiedliche benachbarte Pixelbereiche des Flüssigkristall-Lichtmodulators (LC SLM, engl. liquid-crystal spatial light modulator) für die zwei Polarisationskomponenten genutzt werden. Das hat den Vorteil, dass nur ein einzelnes zweilagiges LC SLM benötigt wird und so ein kompakter und robuster Aufbau realisiert werden konnte. Um die Frequenzverteilung für einen breiten Spektralbereich von 740 – 880 nm anzupassen, wurden die besten Parameter für den Aufbau anhand numerischer Berechnungen bestimmt, und somit die Formungsmöglichkeiten unseres Vektorfeldformers optimiert. Im Gegensatz zu anderen Designs wird ein Dünnschicht-Polarisator (TFP, engl. thin-film polarizer) anstelle eine Wollaston-Prismas verwendet, um die zwei senkrecht zueinander polarisierten Strahlen zu erzeugen und zu rekombinieren, da ein Wollaston-Prisma Artefakte wie Winkelchirp und eine über das Strahlprofiel variierende Phase verursacht. Bei Verwendung eines Wollaston-Prismas muss zudem der rekombinierte Strahl gegenüber des einfallenden Strahls in der Höhe verkippt werden, um beide räumlich trennen zu können. Raytracing-Simulationen haben gezeigt, dass dies in Kombination mit einem Teleskop und dem 4f-Aufbau zu einer erheblichen Deformierung des Strahlprofiles führt. Diese Simulationen haben auch gezeigt, dass die Abbildungsfehler des Aufbaus weitestgehend aufgehoben werden, wenn der eingehende und ausgehende Strahl in derselben Ebene propagieren und somit die Strahlwege genau invertiert werden. Dies konnte mit Hilfe des TFPs in einer Konfiguration, die gekreuzten Polarisatoren entspricht, realisiert werden. Diese Konfiguration hat zudem den Vorteil, dass dadurch die polarisationsabhängige Effizienz des TFPs und der anderen Optiken automatisch kompensiert wird und ein hohes Auslöschungsverhältnis in der Größenordnung 15000:1 erzielt wird. Die chromatische Aberration wird allerdings durch diese Polarisator-Konfiguration nicht aufgehoben. Durch Raytracing wurde bestätigt, dass diese primär durch das Teleskop verursacht wird und nicht durch die Zylinderlinse des 4f-Aufbaus. Allerdings wurden im experimentell genutzten Wellenlängenbereich von 780 – 816 nm nur geringe Störungen des Strahlprofiles beobachtet, die daher als vernachlässigbar angesehen wurden. Die softwareseitige Umsetzung der Vektorfeldkontrolle wurde in Kapitel 5 beschrieben. Um verschiedene Experimente durchführen zu können, wurden fünf Parametrisierungen entwickelt, bei denen die erweiterten Formungsmöglichkeiten eines Vektorfeldformers berücksichtigt wurden. Die Pixel Basis, die Spectral Basis und die Spectral Taylor Basis können zusammen mit einem Optimierungsalgorithmus verwendet werden und sind damit bestens für Experimente der Quantenkontrolle geeignet. Für die multidimensionale Spektroskopie wurde die Polarized Four-Pulse Basis eingeführt. Mit dieser Parametrisierung können Mehrfach-Pulssequenzen mit bis zu vier Pulsen erzeugt werden. Dabei kann der Polarisationszustand jedes Pulses vorgegeben und die relative Intensität, Phase und der zeitliche Abstand aufeinanderfolgender Pulse festgelegt werden. Zusätzlich wurden in Kapitel 5 verschieden Softwareprogramme vorgestellt, die für die in dieser Arbeit durchgeführten Experimente notwendig sind. Die experimentellen Ergebnisse wurden in Kapitel 6 präsentiert. Die Frequenzverteilung am LC SLM wurde gemessen und dabei bewiesen, dass die optimale Frequenzverteilung experimentell realisiert werden konnte. Des Weiteren wurden die exzellenten Eigenschaften des TFPs bestätigt. Im Allgemeinen emittiert der TFP Satellitenpulse durch interne Mehrfachreflexe. Mehrere Messungen haben jedoch gezeigt, dass diese Satellitenpulse einen zeitlichen Abstand von mindesten 4,05 ps vom Hauptpuls aufweisen und dass deren Intensität verschwindend gering ist. Die Phasenstabilität des Aufbaus beträgt σ = 28,3 mrad (λ/222) über einen Zeitraum von einer Stunde. Um die Stabilität für sehr lange Messzeiten zu verbessern, wurde eine Routine zur Phasenreduktion und zur Stabilisierung (OPRAS, engl. on-the-fly phase reduction and stabilization) unter Einbeziehung des Pulsformers entwickelt. Diese Routine erzeugt automatisiert einen komprimierten Puls mit minimierter relativer Phase zwischen den zwei Polarisationskomponenten und ermöglicht so eine Phasenstabilität von σ = 31,9 mrad (λ/197) über nahezu 24 Stunden. Ferner wurden verschieden Pulssequenzen erzeugt und charakterisiert, die die Möglichkeiten der konventionellen Pulsformung übertreffen. Die experimentellen Ergebnisse zeigen, dass geformte Pulse mit beliebigen Phasen, Amplituden und Polarisationszuständen generiert werden können. In allen Fällen wurde eine sehr hohe Übereinstimmung zwischen den Zielparametern und den experimentellen Daten erreicht. Für den zukünftigen Einsatz des Aufbaus wurden mögliche Erweiterungen vorgeschlagen. Diese sind nicht zwingend erforderlich, könnten aber die Leistung und die Einsatzmöglichkeiten des Vektorfeldformers weiter verbessern. Erstens wurde aufgezeigt, wie zwei Ausgangsstrahlen erzeugt werden könnten. Mit dieser Veränderung wäre es möglich, den größten Teil der Intensität des geformten Strahls für ein Experiment zu nutzen und gleichzeitig einen geringen Anteil für die Pulscharakterisierung oder für die Phasenstabilisierung mit der entwickelten Routine zu verwenden. Um chromatische Aberration zu vermeiden, wurde zweitens die prinzipielle Idee, das Linsenteleskop durch fokussierende Spiegel zu ersetzen, diskutiert. Für die verschiedenen erarbeiteten Parametrisierungen zur Vektorfeldkontrolle wurden einige Erweiterungen vorgeschlagen, um deren Einsatzmöglichkeiten noch weiter zu erhöhen. Außerdem wurde noch die Möglichkeit einer von Neumann Basis für den präsentierten Aufbau aufgezeigt. In zukünftigen Experimenten wird unser Aufbau mit einem Photoemissionselektronenmikroskop (PEEM) kombiniert. Dadurch kann die zeitliche Auflösung ultrakurzer Laserpulse mit der hohen räumlichen Auflösung der Elektronenmikroskopie vereint werden, was die zweidimensionale Spektroskopie und Quantenkontrolle von Nanostrukturen mit Hilfe polarisationsgeformter Femtosekunden-Laserpulse ermöglicht. Der Vektorfeldformer eröffnet in Verbindung mit anderen zuvor in unserer Gruppe implementierten chiral sensitiven Versuchsaufbauten neue Perspektiven für die chirale Femtochemie und Kontrolle. Der erarbeitete Vektorfeldformer erfüllt alle Anforderungen, um polarisationsgeformte Mehrfachpulssequenzen mit hoher Präzision zu erzeugen. Diese können verwendet werden, um zahlreiche polarisationssensitive Experimente durchzuführen. Durch die Stabilisierungsroutine OPRAS wird eine quasi unendlich lange Phasenstabilität des Aufbaus gewährleistet und komplexe und aufwendige Langzeitmessungen können ausgeführt werden. Die Tatsache, dass OPRAS keine weitere Hardware benötigt und der Aufbau nur einen einzigen zweilagigen Flüssigkristall-Lichtmodulator sowie ansonsten verhältnismäßig günstige Optiken erfordert, ermöglicht den Bau eines Vektorfeldformers zu vergleichsweise niedrigen Kosten. Wir hoffen, dass andere Forschergruppen von den detailreichen Einblicken in den Designprozess und die Software-Implementierung profitieren und dass die vollständige Vektorfeldformung in den nächsten Jahren genauso wie die konventionelle Pulsformung zu einer Standard-Technologie wird. KW - Ultrakurzer Lichtimpuls KW - vector-field shaper KW - vector-field control KW - polarization pulse shaping KW - femtosecond pulse shaping KW - Vektorfeldformer KW - Vektorfeldkontrolle KW - Polarisationspulsformung KW - Femtosekunden Pulsformung KW - Femtosekundenbereich KW - Impulsformung KW - Femtosekundenlaser Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142948 ER - TY - THES A1 - Schwab, Hubert T1 - Vakuumisolationspaneele : Gas- und Feuchteeintrag sowie Feuchte- und Wärmetransport T1 - vacuum insulation panels- gas and moisture permation as well as heat and moisture transport N2 - Vakuumisolationspaneele (VIP) aus pyrogener Kieselsäure und metallisierten Folien als vakuumdichter Umhüllung wurden untersucht. Der Gas- und Feuchteeintrag durch die Folienumhüllung in das Panel wurde in Abhängigkeit von Folientyp, Panelformat und Klimabedingung ermittelt. Weiterhin wurde der Einfluss der Feuchte auf den transienten und stationären Wärme- und Feuchtetransport bestimmt. Anhand der Ergebnisse lässt sich die Degradation der Dämmwirkung der untersuchten VIPs langfristig prognostizieren. N2 - Vacuum insulation panels (IP) made of fumed silica as core material and metallized foils as vacuum tight envelope were examined. The permeation of gas and moisture through the foil envelope was determined, depending on foil type, panel format and climatic conditions. In addition, the influence of gas and moisture on the transient and stationary heat and moisture transfer was analyzed. The study makes it possible to estimate the long time degradation of the thermal conductivity of the examined VIPs KW - Wärmeschutz KW - Paneel KW - Vakuum KW - Vakuumisolationspanel KW - VIP KW - Wärmeleitfähigkeit KW - Gas KW - Feuchte KW - vacuum insulation panel KW - VIP KW - thermal conductivity KW - gas KW - moisture Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-15224 ER - TY - THES A1 - Schummer, Bernhard T1 - Stabilisierung von CdS Nanopartikeln mittels Pluronic P123 T1 - Stabilization of CdS nanoparticles using Pluronic P123 N2 - Ziel dieser Arbeit war die Stabilisierung von Cadmiumsulfid CdS mit Pluronic P123, einem Polymer. CdS ist ein Halbleiter, der zum Beispiel in der Photonik und bei optischen Anwendungen eingesetzt wird und ist deshalb äußerst interessant, da seine Bandlücke als Nanopartikel verschiebbar ist. Für die Photovoltaik ist es ein attraktives Material, da es im sichtbaren Licht absorbiert und durch die Bandlückenverschiebung effektiver absorbieren kann. Dies ist unter dem Namen Quantum Size Effekt bekannt. Als Feststoff ist CdS für einen solchen Anwendungsbereich weniger geeignet, zumal der Effekt der Bandlückenverschiebung dort nicht auftritt. Wissenschaftler bemühen sich deshalb CdS als Nanopartikeln zu stabilisieren, weil CdS in wässrigen Lösungen ein stark aggregierendes System, also stark hydrophob ist. Es wurden zwei Kriterien für die erfolgreiche Stabilisierung von CdS festgelegt. Zum einen muss das Cds homogen im Medium verteilt sein und darf nicht agglomerieren. Zum anderen, müssen die CdS Nanopartikel kleiner als 100 A sein. In meiner Arbeit habe ich solche Partikel hergestellt und stabilisiert, d.h. verhindert, dass die Partikel weiterwachsen und gleichzeitig ihre Bandlücke verschoben wird. Die Herausforderung liegt nicht in der Herstellung, aber in der Lösung von CdS im Trägerstoff, da CdS in den meisten Flüssigkeiten nicht löslich ist und ausfällt. Die Stabilisierung in wässrigen Lösungen wurde das erste Mal durch Herrn Prof. Dr. Rempel mit Ethylendiamintetraessigsäure EDTA erfolgreich durchgeführt. Mit EDTA können jedoch nur sehr kleine Konzentrationen stabilisiert werden. Zudem können Parameter wie Größe und Geschwindigkeit der Reaktion beim Stabilisieren der CdS-Nanopartikel nicht angepasst oder beeinflusst werden. Dieses Problem ist dem, vieler medizinischer Wirkstoffe sehr ähnlich, die in hohen Konzentrationen verabreicht werden sollen, aber nicht oder nur schwer in Wasser löslich sind (Bsp. Kurkumin). Ein vielversprechender Lösungsweg ist dort, die Wirkstoffe in große Trägerpartikel (sog. Mizellen) einzuschleusen, die ihrerseits gut löslich sind. In meiner Arbeit habe ich genau diesen Ansatz für CdS verfolgt. Als Trägerpartikel/Mizelle wurde das bekannte Copolymer Pluronic P123 verwendet. Aus dieser Pluronic Produktreihe wird P123 gewählt, da es die größte Masse bei gleichzeitig höchstem Anteil von Polypropylenoxid PPO im Vergleich zur Gesamtkettenlänge hat. P123 ist ein ternäres Polyether oder Dreiblockkopolymer und wird von BASAF industriell produziert. Es besteht aus drei Böcken, dem mittlere Block Polypropylenoxid PPO und den beiden äußeren Blöcken Polyethylenoxid PEO. Der Buchstabe P steht für pastös, die ersten beiden Ziffern in P123 mit 300 multipliziert ergeben das molare Gewicht und die letzte Ziffer mit 10 multipliziert entspricht dem prozentualen Gewichtsanteil PEO. Die Bildung von Mizellen aus den P123 Molekülen kann bewusst über geringe Temperaturänderungen gesteuert werden. Bei ungefähr Raumtemperatur liegen Mizellen vor, die sich bei höheren Temperaturen von sphärischen in wurmartige Mizellen umwandeln. Oberhalb einer Konzentration von 30 Gewichtsprozent wtp bilden die Mizellen außerdem einen Flüssigkristall. Ich habe in meiner Arbeit zunächst P123 mit Hilfe von Röntgenstreuung untersucht. Anders als andere Methoden gibt Röntgenstreuung direkten Aufschluss über die Morphologie der Stoffe. Röntgenstreuung kann die Mischung von P123 mit CdS abbilden und lässt darauf schließen, ob das Ziel erreicht werden konnte, stabile CdS Nanopartikel in P123 zu binden. Für die Stabilisierung der Nanopartikel ist es zunächst notwendig die richtigen Temperaturen für die Ausgangslösungen und gemischten Lösungen zu finden. Dazu muss P123 viel genauer untersucht werden, als der momentane Kenntnisstand in der Literatur. Zu diesem Zweck als auch für die Analyse des stabilisierten CdS habe ich ein neues Instrument am LRM entwickelt, sowie eine temperierbare Probenumgebung für Flüssigkeiten fürs Vakuum, um morphologische Eigenschaften aus Streuamplituden und -winkeln zu entschlüsseln. Diese Röntgenstreuanlage wurde konzipiert und gebaut, um auch im Labor P123 in kleinen Konzentrationen messen zu können. Röntgenkleinwinkelstreuung eignet sich besonders als Messmethode, da die Probe mit einer hohen statistischen Relevanz in Flüssigkeit und in verschiedenen Konzentrationen analysiert werden kann. Für die Konzentrationen 5, 10 und 30 wtp konnte das temperaturabhängige Verhalten von P123 präzise mit Röntgenkleinwinkelstreuung SAXS gemessen und dargestellt werden. Für 5 wtp konnten die Größen der Unimere und Mizellen bestimmt werden. Trotz der nicht vorhandenen Absolutkalibration für diese Konzentration konnten dank des neu eingeführten Parameters kappa eine Dehydrierung der Mizellen mit steigender Temperatur abgeschätzt, sowie eine Hysterese zwischen dem Heizen und Abkühlen festgestellt werden. Für die Konzentration von 10 wtp wurden kleinere Temperaturschritte gewählt und die Messungen zusätzlich absolut kalibriert. Es wurden die Größen und Streulängendichten SLD der Unimere und Mizellen präzise bestimmt und ein vollständiges Form-Phasendiagramm erstellt. Auch für diese Konzentration konnte eine Hysterese eindeutig an der Größe, SLD und am Parameter kappa gezeigt werden, sowie eine Dehydrierung des Mizellenkerns. Dies beweist, dass der Parameter kappa geeignet ist, um bei nicht absolut kalibrierten Messungen, Aussagen über die Hydrierung und Hysterese komplexer Kern-Hülle Modelle zu machen. Für die Konzentration von 30 wtp konnte zwischen 23°C und 35°C eine FCC Struktur nachgewiesen werden. Dabei vergrößert sich die Gitterkonstante der FCC Struktur von 260 A auf 289 A in Abhängigkeit der Temperatur. Durch das Mischen zweier Lösungen, zum einen CdCl2 und 30 wtp P123 und zum anderen Na2S und 30 wtp P123, konnte CdS erfolgreich stabilisiert werden. Mit einer Kamera wurde die Gelbfärbung der Lösung, und somit die Bildung des CdS, in Abhängigkeit der Zeit untersucht. Es konnte festgestellt werden, dass das Bilden der CdS Nanopartikel je nach Konzentration und Temperierprogramm zwischen 30 und 300 Sekunden dauert und einer logistischen Wachstumsfunktion folgt. Höhere Konzentrationen CdS bewirken einen schnelleren Anstieg der Wachstumsfunktion. Mittels UV-Vis Spektroskopie konnte gezeigt werden, dass die Bandlücke von CdS mit steigender Konzentration konstant bei 2,52 eV bleibt. Eine solche Verschiebung der Bandlücke von ungefähr 0,05 eV im Vergleich zum Festkörper, deutet auf einen CdS Partikeldurchmesser von 80A hin. Mit SAXS konnte gezeigt werden, dass sich die flüssigkristalline Struktur des P123 bei zwei verschiedenen Konzentrationen CdS, von 0,005 und 0,1 M, nicht ändert. Das CdS wird zwischen den Mizellen, also durch die Bildung des Flüssigkristalls, und im Kern der Mizelle aufgrund seiner Hydrophobizität stabilisiert. Die Anfangs definierten Kriterien für eine erfolgreiche Stabilisierung wurden erfüllt. P123 ist ein hervorragend geeignetes Polymer, um hydrophobes CdS, sowohl durch die Bildung eines Flüssigkristalls, als auch im Kern der Mizelle zu stabilisieren. N2 - Aim of this work was the stabilization of cadmium sulphide CdS with Pluronic P123, a polymer. CdS is a semiconductor, which is used for photonics and for optical applications. It is highly interesting since its band gap can be shifted if it has the size of a nanoparticle. Due to this band gap shift and the fact that CdS is absorbing in the visible range, it is highly attractive material. This is known as the quantum size effect. As a solid, CdS is less interesting in this area because of the non-existing band gap shift. Scientists endeavor to stabilize CdS as a nanoparticle, since CdS is hydrophobic in aqueous solutions and thus a strongly aggregating system. Two criteria of a successful stabilization process were set. Firstly, CdS has to be homogeneously distributed in the solution and must not aggregate. Secondly, the nanoparticles must be smaller then 100A. During my thesis I produced such particles and stabilized them homogeneously in an aqueous solution, which meant to hinder the further growth of those nanopaticles while shifting their band gap. The challenge is not the production, but the encapsulation of CdS in a carrier, since CdS is not soluble in most solutions and precipitates. Such a stabilization in an aqueous solution was succeeded by Prof. Dr. Rempel with ethylenediaminetetraacetic acid EDTA as a stabilizer for the first time. But with EDTA only very small concentrations of CdS can be stabilized. Moreover, properties like size and reaction speed during the stabilization of the CdS nanoparticles cannot be adjusted or influenced. This problem is also known from medical agents, which should be administered in high doses, but are not or barely soluble in water like Curcumin. A promising solution is to encapsulate these medical agents in big carrier, so-called micelles, which themselves are soluble in water. In my thesis I followed this approach for CdS. As a carrier/micelle the well known copolymer Pluronic P123 was used. Compared to other Pluronics, P123 was chosen since it offers the biggest mass with the highest proportion of polypropylene oxide PPO compared to the total chain length. P123 is a ternary polyether and is produced industrially by BASF. It consists of three blocks, where the middle one is PPO and the outer blocks are polyethylene oxide PEO. The letter P stands for pasty while the first two numbers in P123 multiplied with 300 equal the molar mass and the last number multiplied with 10 equals the mass proportion of PEO. The formation of micelles can be triggered on purpose with a change in temperature. Micelles are present at approximately room temperature \cite{Manet2011}, which transform from spherical to worm-like micelles at higher temperatures. Above a certain concentration of 30 weight percent, the micelles will form a liquid crystal. In my work I first examined P123 with X-ray scattering. Unlike other methods, X-ray scattering gives direct information about the morphology of the substances. X-ray scattering can also be used to study the mixture of P123 with CdS and indicates, whether the goal of encapsulate stable CdS nanoparticles in P123 could be achieved. To stabilize the nanoparticles, it is first necessary to find the right temperatures for both the staring point and the end point of the stabilization process. For this purpose, P123 has to be examined much more precisely than the current state of knowledge in the literature. For this purpose as well as for the analysis of the stabilized CdS, I have developed a new instrument at the chair of X-ray microscopy, as well as a temperature controllable sample holder for liquids in vacuum to decipher morphological properties from scattering amplitudes and angles. This X-ray scattering system was designed and built in order to be able to measure P123 in small concentrations in the laboratory. Small-angle X-ray scattering is particularly suitable as a measurement method, since the sample can be analyzed with a high statistical relevance in liquid and in various concentrations. For the concentrations 5, 10 and 30 wtp, the temperature-dependent behavior of P123 could be precisely measured and presented using small-angle X-ray scattering. The sizes of the unimers and micelles could be determined for 5 wtp without an absolute calibration. With a newly introduced parameter kappa, the dehydration of the micelles with increasing temperature could be estimated, despite the lack of the absolute calibration for this concentration, as well as a hysteresis between heating and cooling. Smaller temperature steps were chosen for the concentration of 10 wtp, furthermore the measurements were also absolutely calibrated. The sizes and scattering length densities SLDs of the unimers and micelles were precisely determined and a complete shape-phase diagram was created. Also for this concentration, a hysteresis was clearly shown in terms of size, SLD and the parameter kappa, as well as dehydration of the micellar nucleus. This proves that the parameter kappa is suitable for making statements about the hydrogenation and hysteresis of complex core-shell models in the case of measurements that are not absolutely calibrated. For the concentration of 30 wtp an FCC structure could be detected between 23°C and 35°C. The lattice constant of the FCC structure increases from 260 A to 289 A depending on the temperature. By mixing two solutions, CdCl2 in a 30 wtp P123 and Na2S in 30 wtp P123, CdS could be successfully stabilized. The yellow coloration of the solution, and thus the formation of CdS, was examined as a function of time with the help of a camera. It was found that the formation of the CdS nanoparticles takes between 30 and 300 seconds, depending on the concentration and temperature protocol and follows a logistical growth function. Higher concentrations of CdS cause a more rapid increase in growth function. Using UV-Vis spectroscopy it could be shown that the band gap of CdS remains constant at 2.52 eV with increasing concentration. The shift in the band gap of approximately 0.05 eV compared to the solid state, indicates a CdS particle diameter of 80 A. With SAXS it could be shown that the liquid-crystalline structure of the P123 does not change at two different concentrations of CdS, of 0.005 and 0.1 M. The CdS is stabilized between the micelles due to the formation of the liquid crystal and in the core of the micelles due to their hydrophobicity. The initially defined criteria for successful stabilization were met. P123 is an excellent polymer to stabilize hydrophobic CdS nanoparticles, both through the formation of a liquid crystal and in the core of the micelles. KW - Röntgen-Kleinwinkelstreuung KW - Polymere KW - Cadmiumsulfid KW - Röntgen-Weitwinkelstreuung KW - Nanopartikel KW - Stabilisierung Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-238443 ER - TY - THES A1 - Schumm, Marcel T1 - ZnO-based semiconductors studied by Raman spectroscopy: semimagnetic alloying, doping, and nanostructures T1 - Ramanspektroskopische Untersuchung ZnO-basierte Halbleiter: Semimagnetische Legierung, Dotierung und Nanostrukturen N2 - ZnO-based semiconductors were studied by Raman spectroscopy and complementary methods (e.g. XRD, EPS) with focus on semimagnetic alloying with transition metal ions, doping (especially p-type doping with nitrogen as acceptor), and nanostructures (especially wet-chemically synthesized nanoparticles). N2 - ZnO-basierte Halbleiter wurden mittels Ramanspektroskopie und komplementärer Methoden (z.B. XRD, EPS) untersucht mit den Schwerpunkten semimagnetische Legierung mit Übergangsmetallen, Dotierung (vor allem p-Dotierung mit Stickstoff als Akzeptor) und Nanostrukturen (vor allem nass-chemisch hergestellte Nanopartikel). KW - Wide-gap-Halbleiter KW - Würzburg / Sonderforschungsbereich II-VI-Halbleiter KW - Verbindungshalbleiter KW - Zwei-Sechs-Halbleiter KW - Semimagnetischer Halbleiter KW - n-Halbleiter KW - Niederdimensionaler Halbleiter KW - p-Halbleiter KW - Kolloider Halbleiter KW - Magnetisch KW - Ramanspektroskopie KW - Raman KW - Zinkoxid KW - ZnO KW - DMS KW - Raman spectroscopy KW - Raman KW - Zinc oxide KW - ZnO KW - DMS KW - Diluted Magnetic Semiconductors KW - doping KW - secondary phases Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-37045 ER - TY - THES A1 - Schumacher, Claus T1 - Herstellung und Charakterisierung von Nanostrukturen auf der Basis von II-VI-Materialien mittels der Schattenmaskentechnologie T1 - Fabrication and characterisation of nano structures based on II-VI-materials utilising the shadow mask technology N2 - Warum eigentlich Schattenmasken als neues alternatives Verfahren zur lateralen Strukturierung? Alle bislang üblichen Verfahren zur Herstellung lateral begrenzter Halbleiter-Kristalle strukturieren die zuvor epitaktisch flächig aufgewachsenen Schichten nachträglich. Hierdurch können Probleme entstehen. Etwa erzeugen nach einem nasschemischen Ätzprozess freistehende Quantentröge im Randbereich Oberflächenzustände, die zu nicht strahlender Rekombination führen können und daher die Lichtausbeute reduzieren. Der Prozess des erneuten Überwachsens solcher nachträglich geätzter Strukturen ist bislang noch nicht reproduzierbar. Weitere alternative Techniken, wie das Wachstum selbstorganisierter Quantenpunkte oder das it in-situ Spalten, bieten entweder noch keine befriedigende Kontrollmöglichkeit der Strukturgröße oder sind für eine industrielle Anwendung nur wenig praktikabel. Deshalb richtete sich der Blick auf das aus der III-V-Epitaxie bekannte Schattenmasken-Verfahren zur Herstellung makroskopischer sogenannter ,,nipi-Strukturen''. Diese zeigen den interessanten Effekt, dass sich die durch eine Schattenmaske wachsende Struktur in Wachstumsrichtung während des Wachstums von selbst zuspitzt. Die Größe der Masken-Apertur kann dadurch in einer Größenordnung bleiben, wie sie durch ein ultra-violett optisch lithographisches Verfahren hergestellt werden kann. Durch die Maske wächst dennoch, unterstützt von Schatten- und Selbstorganisationseffekten, ein Halbleiter-Kristall, der an seiner Spitze die Ausdehnung einer Nanostruktur hat. Im Rahmen dieser Arbeit gelang es erstmals mittels der Schattenmaskentechnologie eine ZnSe-Draht-Struktur herzustellen, deren Ausdehnung an der Spitze nur noch 25~nm beträgt. Da dieses Verfahren erstmals zur Herstellung von II-VI-Halbleiter-Schichten etabliert wurde, konnte auf keinerlei Vorarbeiten zurückgegriffen werden. Vor der Herstellung geeigneter Schattenmasken mussten zunächst geeignete Belichtungs-Masken für die optische Lithographie entworfen werden, bevor die Ätztechniken zur Herstellung der Schattenmasken selbst optimiert werden konnten. Am Ende der Schattenmaskenentwicklung stand ein Verfahren zur Präparation einer verlässlichen Startoberfläche für die anschließende II-VI-Epitaxie, ohne die ein reproduzierbares Wachstum durch die Schattenmaske nicht möglich ist. Nachdem die technologische Seite abgearbeitet war, mussten anhand geeigneter Epitaxieexperimente die Einflüsse durch die geänderten Wachstumsbedingungen erforscht werden. Insbesondere spielen beim Wachstum durch Schattenmasken Oberflächeneffekte wie Diffusion oder die Orientierung der Masken-Apertur bzgl. der Kristallrichtung eine wesentliche Rolle. Für die in dieser Arbeit verwendete Geometrie des Wachstums (Gruppe-II- und Gruppe-VI-Spezies werden aus bzgl. der Masken-Apertur spiegelbildlichen Raumwinkelbereichen angeboten) wurde herausgefunden, dass die Maskenöffnung entlang der [1-10]-Kristallrichtung orientiert sein sollte. Entlang dieser Richtung sind die Se-Dimere einer Se-reich rekonstruierten Oberfläche orientiert und somit verläuft die Vorzugsdiffusionsrichtung senkrecht zum Draht. Hierdurch können diffusionsgestützt schärfer definierte Flanken des Drahtes wachsen, als bei einer um 90° gedrehten Geometrie. Eigentlich soll nicht nur eine binäre Drahtstruktur entstehen, sondern es soll zum Beispiel ein ZnCdSe-Quantentrog in einen Draht aus einem geeigneten Barriere-Material eingebettet werden. Bei diesen Versuchen stellte sich anhand von Tieftemperatur-PL- und charakteristischen Röntgenphotonen-Spektren heraus, dass Cadmium in einem epitaktisch gewachsenen Draht stärker als andere Spezies auf der Wachstumsoberfläche diffundiert. Eine kontrollierte Deposition eines ZnCdSe-Quantentroges ist nicht möglich. Um Diffusionseffekte zu vermeiden kann statt eines ternären Troges ein binärer in eine nun quaternäre Barriere eingebettet werden. Dieser Ansatz wird bereits in einer parallel zu dieser Arbeit begonnenen Dissertation erfolgreich verfolgt. Bei der Etablierung eines neuen Verfahrens zur Herstellung von Halbleiter-Kristallen müssen auch Aussagen über die strukturellen Eigenschaften der gewachsenen Strukturen getroffen werden. Hierzu wurden die mittels eines ,,Lift-Off''-Prozesses nun freistehenden Drahtstrukturen einer Röntgenstrukturanalyse unterzogen. Die reziproken Gitterkarten zeigen bei senkrechter Orientierung der Beugungsebene relativ zum Draht, dass der Schichtreflex nicht auf der Relaxationsgeraden liegt. Bei einer rein plastischen Relaxation eines Halbleiter-Kristalls müsste dies jedoch für beide Orientierungen der Beugungsebene (senkrecht und parallel zum Draht) der Fall sein. Der Schichtreflex ist in Richtung des Substratreflexes verschoben. Der Netzebenenabstand ist somit also verkleinert. Eine mögliche Erklärung hierfür ist die zylinderförmige ,,Verbiegung'' der Atomebenen im Realraum und somit der Netzebenen im reziproken Raum. Die Überlegungen führen somit auf eine zusätzlich elastische anstelle auschließlich plastischen Relaxation des Kristalls. Um eine solche These erhärten zu können wurde auf der Basis der aus den REM- und AFM-Bildern ausgewerteten Geometrie der Drahtstrukturen ein atomares Modell eines verspannten Kristalls erstellt. Mittels eines Monte-Carlo-Algorithmus' kann dieses Modell seine eingeprägte Verspannungsenergie elastisch abbauen. Die Fouriertransformierte des Realraumbildes des elastisch relaxierten Drahtes lässt sich direkt mit den reziproken Gitterkarten vergleichen. Mittels dieser Simulation konnte die vertikale Verschiebung des Schichtreflexes unmittelbar den zylindrisch ,,verbogenen'' Kristallebenen zugeordnet werden. Ferner ermöglichen die Simulationen erstmalig die qualitative Interpretation der Beugungsmessungen an den Schattenmasken selbst. Die im Rahmen der Dissertation von H.R.~Ress vorgenommenen Beugungsmessungen an den Schattenmasken zeigen neben der vertikalen Verschiebung des AlGaAs-Schichtreflexes charakteristische diffuse Streifen um den Schichtreflex, die bislang unverstanden waren. Die Simulationen zeigen, dass diese Streifen erst bei der elastischen Relaxation des Drahtes durch die konvexe Wölbung der Drahtflanke entstehen. Diese diffusen Streifen lassen sich in den in dieser Arbeit gewachsenen Drähten aus II-VI-Halbleitern nicht unmittelbar nachweisen. Da die Schattenmasken bedingt durch das Herstellungsverfahren eine Rauigkeit der Schattenkanten von bis zu 150~nm aufweisen sind auch die Flanken der durch die Masken gewachsenen Strukturen stark aufgeraut. Deshalb streuen die den Draht begrenzenden Fassetten nicht kohärent und bieten entsprechend keine definierte Abbruchbedingung der Fouriertransformation. N2 - What is the motivation for the establishment of an alternative technique for lateral structuring? Till date, for definition of semiconductor nano structures, the established technology relies on the post-growth, ex-situ structuring of layer samples. The processes involved in this technology may cause a number of problems. For instance, wet chemical etching of quantum wires generate surface states which result in non radiative recombination of carriers and hence reduce the optical efficiency. Secondly, the process of overgrowth of such etched structures is not well controlled so far. Further alternative techniques like self organised growth of quantum dots or in-situ cleaved edge overgrowth either do not provide a satisfying size control or are too laborious for them to be industrially practicable. Thus, efforts were directed towards the use of shadow mask technique, a process well established for the fabrication of III-V n-i-p-i structures. These structures exhibit the interesting effect of an acuminating crystal during growth. A standard optical lithography process which achieves mask apertures down to 300~nm is sufficient: Driven by the effect of shadow and self organisation, the structure growing within the growth cavity has nano scale dimension at its tip. In the course of the work we succeeded, for the first time, to fabricate a ZnSe wire structure with a tip width of only 25nm. Since this technique was applied to the II-VI semiconductors for the first time, no relevant literature was available for the the preparatory work. Prior to the fabrication of suitable shadow masks, it is required to (a) design lithographic masks and (b) establish appropriate etching procedures. Additionally, the procedure requires the preparation of a reliable III-V surface for the subsequent II-VI growth. After successful implementation of the techniques, suitable experiments were developed which enabled the investigation of the growth conditions for the growth within a growth cavity. In particular, surface effects, like diffusion or the orientation of the mask aperture with respect to the symmetry directions of the crystal, play an considerable role. For the samples dicussed in this work, an alignment of the effusion cells was performed such that, group II and VI molecular beams impinged on the substrate at equal incident angles with respect to the surface normal. In this geometry, it was found that the highest lateral precision is achieved with mask apertures parallel to the [1-10] crystal direction. The selenium dimers are oriented along this direction and hence the main diffusion occures perpendicular to the wire. Hence the edges of the forming wire are more pronounced in this orientation. Originally, not only binary but also ternary quantum structures, for instance ZnCdSe quantum wells embedded into ZnSe barriers, were planned. Low temperature PL and EDAX experiments revealed that the cadmium diffusion coefficient is much larger than those of zinc and selenium. Therefore, a homogeneous cadmium distribution inside the ternary quantum well alloy, could not be achieved. To overcome this problem of segregation, a binary well can be embedded within a quaternary barrier. This approach was successfully pursued in a parallel endeavour. When a novel technique for fabrication of semiconductor structures is established, it is indespensable to provide evidence of high structural quality of the grown crystals. Therefore, the free standing wire structures were probed by high resolution x-ray diffraction analysis after the removal of the mask (lift-off process). The reciprocal space maps acquired in these experiments exhibit that the layer reflection does not lie on the line of relaxation only when the plane of diffraction is aligned perpendicular to the wire. Considering only plastic relaxation of the lattice, a deviation from the line of relaxation should occur for neither parallel nor perpendicular orientation. The layer reflection has moved towards the substrate reflection. The distance of lattice planes has therefore decreased. One possible explanation for this is a cylindrically shaped ''bending'' of atom planes in real space and consequentially of the lattice planes in reciprocal space. In conclusion, an additional elastic, instead of solely plastic relaxation, of the crystal has to be considered. To substantiate such a thesis, an atomic model was developed. The geometry of the modelled wire structures was choosen, based on the SEM and AFM images. The strain incorporated into the modelled crystal was relaxed by means of a Monte Carlo algorithm. The fourier transform of the real space image is related to the reciprocal space map directly. Based one this simulations, the vertically displacement of the layer reflection can be attributed to cylindrically bending of the lattice planes. Furthermore, these simulations enabled a qualitative interpretation of the diffractograms of the shadow masks themselves. In the course of this work, diffraction measurements were carried out on the III-V shadow masks by H.R. Ress. Apart from the vertical displacement of the AlGaAs layer reflection they were found to exhibit a characteristic cross-shaped diffuse reflection surrounding the layer reflection. This effect was not understood until now. The simulations clarified these features as due to a convex curvature of the wire's edges. Due to the low scattering volume of the II-VI wire structures fabricated in this work, these diffuse intensity is not observeable. Additionally, the fabrication technique itself brings in a roughness of the mask's shadow edges of roughly 150~nm, which in turn affects the roughness of wire structure. Hence the bounding facets of the wire do not scatter coherently and hence no defined termination condiction of the fourier transform is defined. KW - Zwei-Sechs-Halbleiter KW - Nanostruktur KW - Molekularstrahlepitaxie KW - Fernsehmaske KW - Schattenmaske KW - Halbleiter KW - MBE KW - Quantendraht KW - Nanostruktur KW - shadow mask KW - semiconductor KW - mbe KW - quantum wire KW - nano structure Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8754 ER - TY - THES A1 - Schreyer, Manuel T1 - Search for supersymmetry in events containing light leptons, jets and missing transverse momentum in \(\sqrt{s}\) = 8 TeV pp collisions with the ATLAS detector T1 - Suche nach Supersymmetrie in Ereignissen mit leichten Leptonen, Jets und fehlendem Transversalimpuls in pp-Kollisionen bei \(\sqrt{s}\) = 8 TeV mit dem ATLAS-Detektor N2 - The results of two analyses searching for supersymmetry (SUSY) in data of the ATLAS experiment are presented in this thesis. The data were recorded in proton-proton collisions at the Large Hadron Collider in 2012 at a centre of mass energy of \(\sqrt{s}\)=8 TeV and correspond to an integrated luminosity of 20.3 fb\(^{−1}\). The first search is performed in signatures containing an opposite-sign electron or muon pair, which is compatible with originating from a Z boson decay, in addition to jets and large missing transverse momentum. The analysis targets the production of squarks and gluinos in R-parity conserving (RPC) models with SUSY breaking via General Gauge Mediation (GGM). The main Standard Model (SM) backgrounds are \(t\overline t\), WW, W+t and Z to \(\tau \tau\) processes which are entirely estimated from data using different-flavour events. Besides that, the SM production of Z bosons in association with jets and large fake missing momentum from mismeasurements plays a role and is predicted with the data-driven jet smearing method. Backgrounds from events with fake leptons are estimated with the data-driven matrix method. WZ/ZZ production as well as smaller background contributions are determined from Monte-Carlo simulations. The search observes an excess of data over the SM prediction with a local significance of 3.0 \(\sigma\) in the electron channel, 1.7 \(\sigma\) in the muon channel and 3.0 \(\sigma\) when the two channels are added together. The results are used to constrain the parameters of the GGM model. The second analysis uses the already published results of an ATLAS search for SUSY in events with one isolated electron or muon, jets and missing transverse momentum to reinterpret them in the context of squark and gluino production in SUSY models with R-parity violating (RPV) \(LQ\overline D\)-operators. In contrast to RPC models, the lightest SUSY particle (LSP) is not stable but decays into SM particles. "Standard" analyses often do not consider SUSY models with RPV although they are in principle sensitive to them. The exclusion limits on the squark and gluino mass obtained from the reinterpretation extend up to 1200 GeV. These are the first results by any ATLAS SUSY search which systematically cover a wide range of RPV couplings in the case of prompt LSP decays. However, the analysis is not sensitive to the full parameter space of the \(LQ\overline D\)-model and reveals gaps in the ATLAS SUSY program which have to be closed by dedicated search strategies in the future. N2 - In dieser Arbeit werden die Ergebnisse von zwei Suchen nach Supersymmetrie (SUSY) in Daten des ATLAS-Experiments präsentiert. Die Messdaten wurden im Jahr 2012 in Proton-Proton-Kollisionen am Large Hadron Collider bei einer Schwerpunktsenergie von \(\sqrt{s}\) = 8 TeV gewonnen und entsprechen einer integrierten Luminosität von 20,3 fb\(^{−1}\). Die erste Suche verwendet Signaturen mit Jets, großem fehlenden Transversalimpuls sowie einem Elektron- oder Myonpaar mit entgegengesetzter Ladung, dessen Eigenschaften mit einem Leptonpaar aus dem Zerfall eines Z-Bosons vereinbar sind. Die Analyse zielt auf die Untersuchung von Squark- und Gluinoproduktion im Rahmen R-paritätserhaltender (RPC) Modelle mit SUSY-Brechung durch General Gauge Mediation (GGM) ab. Die Hauptuntergründe des Standardmodells (SM) sind \(t\overline t\), WW, W+t und Z nach \(\tau \tau\) Prozesse. Diese werden komplett aus den Daten selbst unter Verwendung von Ereignissen mit Leptonpaaren unterschiedlichen Flavours abgeschätzt. Daneben spielt der Untergrund aus der SM-Produktion von Z-Bosonen in Verbindung mit Jets und großem fehlenden Impuls, der durch Fehlmessungen fälschlicherweise rekonstruiert wird, ein Rolle. Dieser wird mit der datengestützten Jet-Smearing-Methode abgeschätzt. Der Hintergrundbeitrag von Ereignissen mit fehlidentifizierten Leptonen wird mit der datengestützten Matrix-Methode bestimmt, während die Produktion von WZ/ZZ-Paaren sowie kleinere Untergrundprozesse mit Hilfe von Monte-Carlo-Simulationen abgeschätzt werden. Die Suche beobachtet einen Überschuss an Daten über der SM-Vorhersage mit einer lokalen Signifikanz von 3,0 \(\sigma\) im Elektronkanal, 1,7 \(\sigma\) im Myonkanal und 3,0 \(\sigma\), wenn beide Kanäle zusammengezählt werden. Mit den Ergebnissen lassen sich die Parameter des GGM-Modells einschränken. Die zweite Analyse interpretiert die bereits veröffentlichten Ergebnisse einer ATLAS SUSY-Suche in Ereignissen mit einem isolierten Elektron oder Myon, Jets und fehlendem Transversalimpuls im Rahmen von Squark- und Gluinoproduktion in SUSY-Modellen, in denen die R-Parität durch \(LQ\overline D\)-Operatoren verletzt wird. Im Gegensatz zu RPC-Modellen ist das leichteste SUSY-Teilchen (LSP) dort nicht stabil, sondern zerfällt in SM-Teilchen. R-paritätsverletzende (RPV) SUSY-Modelle werden von "Standardanalysen" oft vernachlässigt, obwohl diese prinzipiell sensitiv auf RPV SUSY sind. Die Ausschlussgrenzen auf die Squark- und Gluinomasse, die sich aus der Reinterpretation ergeben, reichen bis zu 1200 GeV. Dies sind die ersten derartigen Ergebnisse einer ATLAS SUSY-Suche, die einen großen Bereich möglicher RPV-Kopplungen für den Fall prompter LSP-Zerfälle auf systematische Art und Weise abdecken. Allerdings ist die Analyse nicht im gesamten Parameterraum des \(LQ\overline D\)-Modells sensitiv und deckt somit Lücken im ATLAS SUSY-Programm auf. Diese sollten in Zukunft durch speziell optimierte Suchstrategien geschlossen werden. KW - Supersymmetrie KW - Supersymmetry KW - Supersymmetrie KW - LHC KW - ATLAS-Detektor KW - Neue Physik KW - New physics KW - ATLAS KW - Proton-Proton-Streuung Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-120863 ER -