TY - JOUR A1 - Kimpel, Otilia A1 - Schindler, Paul A1 - Schmidt-Pennington, Laura A1 - Altieri, Barbara A1 - Megerle, Felix A1 - Haak, Harm A1 - Pittaway, James A1 - Dischinger, Ulrich A1 - Quinkler, Marcus A1 - Mai, Knut A1 - Kroiss, Matthias A1 - Polat, Bülent A1 - Fassnacht, Martin T1 - Efficacy and safety of radiation therapy in advanced adrenocortical carcinoma JF - British Journal of Cancer N2 - Background International guidelines emphasise the role of radiotherapy (RT) for the management of advanced adrenocortical carcinoma (ACC). However, the evidence for this recommendation is very low. Methods We retrospectively analysed all patients who received RT for advanced ACC in five European centres since 2000. Primary endpoint: time to progression of the treated lesion (tTTP). Secondary endpoints: best objective response, progression-free survival (PFS), overall survival (OS), adverse events, and the establishment of predictive factors by Cox analyses. Results In total, 132 tumoural lesions of 80 patients were treated with conventional RT (cRT) of 50–60 Gy (n = 20) or 20–49 Gy (n = 69), stereotactic body RT of 35–50 Gy (SBRT) (n = 36), or brachytherapy of 12–25 Gy (BT) (n = 7). Best objective lesional response was complete (n = 6), partial (n = 52), stable disease (n = 60), progressive disease (n = 14). Median tTTP was 7.6 months (1.0–148.6). In comparison to cRT\(_{20-49Gy}\), tTTP was significantly longer for cRT\(_{50-60Gy}\) (multivariate adjusted HR 0.10; 95% CI 0.03–0.33; p < 0.001) and SBRT (HR 0.31; 95% CI 0.12–0.80; p = 0.016), but not for BT (HR 0.66; 95% CI 0.22–1.99; p = 0.46). Toxicity was generally mild and moderate with three grade 3 events. No convincing predictive factors could be established. Conclusions This largest published study on RT in advanced ACC provides clear evidence that RT is effective in ACC. KW - adrenal tumours KW - adrenocortical carcinoma (ACC) KW - radiotherapy (RT) Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324411 VL - 128 IS - 4 ER - TY - JOUR A1 - Lisowski, Dominik A1 - Lutyj, Paul A1 - Abazari, Arya A1 - Weick, Stefan A1 - Traub, Jan A1 - Polat, Bülent A1 - Flentje, Michael A1 - Kraft, Johannes T1 - Impact of Radiotherapy on Malfunctions and Battery Life of Cardiac Implantable Electronic Devices in Cancer Patients JF - Cancers N2 - Purpose: This study analyses a large number of cancer patients with CIEDs for device malfunction and premature battery depletion by device interrogation after each radiotherapy fraction and compares different guidelines in regard to patient safety. Methods: From 2007 to 2022, a cohort of 255 patients was analyzed for CIED malfunctions via immediate device interrogation after every RT fraction. Results: Out of 324 series of radiotherapy treatments, with a total number of 5742 CIED interrogations, nine device malfunctions (2.8%) occurred. Switching into back-up/safety mode and software errors occurred four times each. Once, automatic read-out could not be performed. The median prescribed cumulative dose at planning target volume (PTV) associated with CIED malfunction was 45.0 Gy (IQR 36.0–64.0 Gy), with a median dose per fraction of 2.31 Gy (IQR 2.0–3.0 Gy). The median maximum dose at the CIED at time of malfunction was 0.3 Gy (IQR 0.0–1.3 Gy). No correlation between CIED malfunction and maximum photon energy (p = 0.07), maximum dose at the CIED (p = 0.59) nor treatment localization (p = 0.41) could be detected. After excluding the nine malfunctions, premature battery depletion was only observed three times (1.2%). Depending on the national guidelines, 1–9 CIED malfunctions in this study would have been detected on the day of occurrence and in none of the cases would patient safety have been compromised. Conclusion: Radiation-induced malfunctions of CIEDs and premature battery depletion are rare. If recommendations of national safety guidelines are followed, only a portion of the malfunctions would be detected directly after occurrence. Nevertheless, patient safety would not be compromised. KW - battery depletion KW - cardiac implantable electronic devices (CIED) KW - cardiac resynchronization therapy (CRT) KW - implantable cardioverter defibrillator (ICD) KW - CIED malfunction; pacemaker (PM) KW - radiotherapy (RT) Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-358008 SN - 2072-6694 VL - 15 IS - 19 ER -