TY - THES A1 - Kühnreich, Raphael T1 - Development and Validation of Methods for Impurity Profiling of Amino Acids T1 - Entwicklung und Validierung von Methoden für die Reinheitsanalytik von Aminosäuren N2 - The requirements for the impurity profiling of substances for pharmaceutical use have become greater over time. They can be accomplished by the use of modern instrumental analysis techniques, which have been evolved in the last decades. New types of columns with HILIC, mixed-mode and chiral stationary phases are suitable for the separation of all kinds of substances mixtures, that were previously hardly possible with the use of common reversed phase columns. Modern, almost universal detectors like CAD, ELSD and CNLSD can be applied for a sensitive detection of substances without a chromophore. However, in addition to some small individual disadvantages to these methods, the costs are high and applications are still kind of rare. Thus, the introduction of these devices at a broader level has not yet taken place. While this presumably will change over time, there is a need for methods that enable the impurity profiling of challenging substances with widespread analytics devices. Methionine is a substance with hydrophobic and hydrophilic impurities. With the help of a mixed-mode stationary phase, which is a combination of a reversed phase and a strong cationic exchanger, the separation of all putative impurities was found possible with good sensitivity and selectivity. The method requires apart from the column only standard isocratic HPLC equipment and was successfully validated. The evaluation of the enantiomeric purity of amino acids is challenging. Two approaches were made. The first method utilizes CE by means of in-capillary derivation with OPA and the subsequent separation with a cyclodextrin. With the use of OPA/NAC and γ-cyclodextrin, a simple and cost-effective method for the indirect enantioseparation of 16 amino acids was developed. With the second approach, racemic amino acids can be analyzed with HPLC and in-needle derivatization. For this, different columns and chiral thiols were evaluated and the chromatographic parameters were optimized. A method with OPA/NIBLC, a pentafluorophenyl column made the enantioseparation of 17 amino acids feasible. A LOQ of the minor enantiomer down to 0.04 % can be achieved with UV spectrophotometric detection. A similar method was developed for impurity profiling of L-amino acids. This can be used alternatively for the amino acid analysis performed by the European Pharmacopoeia. A simple, robust, precise and accurate method for the evaluation of impurities in glyceryl trinitrate solution was developed and validated. The four impurities of glyceryl trinitrate are separated by means of an acetonitrile-water gradient and the assay for this substance is also possible. N2 - Die Anforderungen an die Reinheitsanalytik von Substanzen für pharmazeutische Zwecke sind mit der Zeit größer geworden. Diese können durch die Verwendung von modernen instrumentellen Analysetechniken, die sich in den letzten Jahrzehnten entwickelt haben, erfüllt werden. Neue Arten von Säulen mit HILIC, mixed-mode und chiralen Phasen sind geeignet für die Trennung von allen möglichen Substanzgemischen, die vorher mit der Verwendung von gewöhnlichen Umkehrphasensäulen kaum möglich waren. Moderne, fast universelle Detektoren wie CAD, ELSD und CNLSD können für eine sensitive Detektion von Substanzen ohne Chromophor verwendet werden. Allerdings, neben ein paar individuellen Nachteilen von diesen Methoden, sind die Kosten sehr hoch und die Anwendungen noch eher selten. Daher haben sich diese Geräte noch nicht auf breiter Ebene durchgesetzt. Auch wenn sich das mit der Zeit ändern wird, gibt es die Notwendigkeit für Analysemethoden mit denen die Reinheitsanalytik von herausfordernden Substanzen auf verbreiteten analytischen Geräten ermöglicht wird. Methionin ist eine Substanz mit hydrophilen und hydrophoben Verunreinigungen. Mit der Hilfe einer „mixed-mode“-Phase, welche eine Kombination aus Umkehrphase und starker Kationenaustauscher ist, wurde die Trennung von allen mutmaßlichen Verunreinigungen mit guter Sensitivität und Selektivität ermöglicht. Die Methode benötigt abgesehen von der Säule nur eine normale isokratische HPLC und wurde erfolgreich validiert. Die Untersuchung der chiralen Reinheit von Aminosäuren ist anspruchsvoll. Zwei Ansätze wurden durchgeführt. Die erste Methode verwendet CE mittels In-Capillary- Derivatisierung durch OPA und der anschließenden Trennung mit Hilfe von einem Cyclodextrin. Durch den Gebrauch von OPA/NAC und γ-Cyclodextrin, wurde eine einfache und kosteneffektive Methode für die indirekte Enantioseparation von 16 Aminosäuren entwickelt. Mit dem zweiten Ansatz können Aminosäuren mittels HPLC und einer In-Needle- Derivatisierung analysiert werden. Dafür wurden verschiedene Säulen und chirale Thiole getestet und die chromatographischen Parameter optimiert. Eine Methode mit OPA/NIBLC, einer Pentafluorophenyl-Säule ermöglichte die Trennung on 17 Aminosäuren. Ein LOQ des kleinen Enantiomers von 0,04 % kann mit UV-spektroskopischer Detektion erreicht werden. Eine ähnliche Methode wurde für die Reinheitsanalytik von L-Aminosäuren entwickelt. Diese kann alternativ zur Aminosäurenanalyse im Europäischen Arzneibuch verwendet werden. Zusammenfassung 163 Eine einfache, robuste, präzise und richtige Methode zur Untersuchung der Verunreinigungen in Glyceryltrinitratlösung wurde entwickelt und validiert. Die vier Verunreinigungen von Glyceryltrinitrat werden mit Hilfe eines Acetonitril-Wasser-Gradienten getrennt und die Gehaltsbestimmung dieser Substanz ist ebenfalls möglich. KW - Aminosäuren KW - HPLC KW - Enantiomere KW - Trennung KW - amino acid KW - impurity profiling KW - chiral separation KW - Aminosäure KW - Reinheitsanalytik KW - chirale Trennung Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-145718 ER - TY - THES A1 - Wahl, Oliver T1 - Impurity Profiling of Challenging Active Pharmaceutical Ingredients without Chromophore T1 - Erstellen von Verunreinigungsprofilen von anspruchsvollen Wirkstoffen ohne Chromophor N2 - The impurity profiling of pharmaceutical ingredients can oppose many challenges. The best part of active pharmaceutical ingredients (APIs) and the related substances are detectable by UV detection, a very common detection principle. However, if an API lacks a suitable chromophore other means of detection are necessary. The corona charged aerosol detector (CAD) is a detector capable of detecting substances independent of their chemical structure. This “universal” detector has only one limitation: The analyte has to have a sufficiently low vapor pressure. Another important challenge that comes often together with the lack of a chromophore concerns the separation. These substances (e.g. most amino acids and derivatives) often contain structures that make them difficult to retain on conventional reversed phase columns. Possible solutions to overcome these challenges, like the application of the CAD and the benefit of so-called mixed-mode stationary phases in impurity profiling for pharmacopoeial purposes were explored in this work. The related substances analyzed in this thesis comprise amino acids, inorganic ions, bisphosphonic acids, basic and acidic derivatives of amino acids (esters and amides). The successful development and validation of mixed-mode liquid chromatography methods with CAD detection for carbocisteine and ibandronate sodium might help to increase the acceptance of this versatile detector in the pharmaceutical industry and in official authorities dealing with the determination of related substances. The combination of UV and CAD detection proved very useful during the analysis of Bicisate. Most of the related substances and some unidentified impurities were detectable by CAD whereas a synthesis by-product, a semi-volatile ester, was only detectable in the UV trace. The simple combination covers all relevant impurities in a single analysis. Two truly orthogonal methods regarding separation and detection for the enantiomeric purity of magnesium-L-aspartate helped to find the reason for elevated D aspartic acid content in the drug substance. A very quick and sensitive indirect separation using the OPA derivatization with NAC was developed as a powerful screening tool, whereas the direct separation of D- and L-CBQCA-Asp derivatives confirmed the results. Both methods were optimized in order to do without substances mentioned on the REACH list, like sodium tetraborate which is very frequently applied in standard derivatization protocols and CE separations. The importance of orthogonal detection principles in the determination of related substances of amino acids was discussed in a review article dealing with the revision of amino acid monographs in the Ph. Eur.. N2 - Die Reinheitsprüfung pharmazeutischer Wirkstoffe kann den Analytiker vor verschiedene Hürden stellen. So gilt für den größten Teil pharmazeutischer Wirkstoffe und deren verwandte Substanzen, dass sie mit Hilfe des weit verbreiteten UV-Detektors nachweisbar sind. Verfügt ein Wirkstoff hingegen nicht über ein geeignetes Chromophor, so benötigt man andere Möglichkeiten der Detektion. Der corona charged aerosol detector (CAD) ist in der Lage Substanzen unabhängig von ihrer chemischen Struktur zu detektieren, vorausgesetzt, sie sind schwerflüchtig. Eine weitere Herausforderung, die häufig mit dem Fehlen eines Chromophors einhergeht betrifft die Trennung. Verbindungen dieser Art (z.B. die meisten Aminosäuren und deren Derivate) enthalten häufig Strukturen, die eine Trennung auf konventionellen Umkehrphasen erschweren. Mögliche Ansätze um die genannten Herausforderungen zu meistern, wie zum Beispiel die Verwendung des CAD und sogenannter mixed-mode Phasen in der pharmazeutischen Reinheitsanalytik wurden erarbeitet und an konkreten Anwendungen erprobt. Die in dieser Arbeit bestimmten verwandten Substanzen sind vor allem Aminosäuren, anorganische Ionen, Bisphosphonate sowie basische und saure Derivate von Aminosäuren (Ester und Amide). Die erfolgreiche Entwicklung und Validierung von mixed-mode flüssig-chromatographischer Methoden kombiniert mit CAD für Carbocistein und Ibandronat Natrium könnte dabei helfen die Akzeptanz in der Pharmazeutischen Industrie und bei den für Reinheitsprüfungen zuständigen Behörden für diesen vielseitigen Detektor zu verbessern. Die Kombination von UV-Detektion und CAD erwies sich bei der Analyse von Bicisate als sehr nützlich. Die meisten verwandten Substanzen und einige unbekannte Verunreinigungen konnten mittels CAD detektiert werden, während ein Nebenprodukt der Synthese, ein halb-flüchtiger Ester, nur mit Hilfe des UV Detektors sichtbar war. Die Kombination zweier Detektionstechniken ermöglichte die Bestimmung aller relevanten Verunreinigungen in einer einzigen Analyse. Die Bestimmung der optischen Reinheit von Magnesium-L-Aspartat gelang mittels zweier orthogonaler Methoden und der Grund für das Auftreten von erhöhten Konzentrationen an D-Aspartat wurde gefunden. Eine schnelle indirekte Bestimmung der OPA/NAC-Derivate eignete sich als Screening-tool, während die direkte Trennung der enantiomeren CBQCA-Derivate die Ergebnisse bestätigte. Beide Methoden wurden im Hinblick darauf optimiert, dass sie ohne Substanzen wie Natriumtetraborat, eine Substanz auf der REACH Liste für besonders besorgniserregende Substanzen, sowie gebräuchlicher Puffer bei Derivatisierungsreaktionen und CZE Trennungen, auskamen. Die Bedeutung von orthogonalen Detektionstechniken bei der Bestimmung der verwandten Substanzen von Aminosäuren wurde in einem Übersichtsartikel, der in Zusammenhang mit der Revision von Aminosäuren Monographien des Europäischen Arzneibuches steht, diskutiert. KW - Chromatographie KW - Verunreinigung KW - Impurity Profiling KW - Amino acids KW - Corona charged aerosol detector KW - Aminosäuren Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-137205 ER -