TY - JOUR A1 - Wurmb, Thomas A1 - Vollmer, Tina A1 - Sefrin, Peter A1 - Kraus, Martin A1 - Happel, Oliver A1 - Wunder, Christian A1 - Steinisch, Andrias A1 - Roewer, Norbert A1 - Maier, Sebastian T1 - Monitoring of in-hospital cardiac arrest events with the focus on Automated External Defibrillators – a retrospective observational study JF - Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine N2 - Background Patients with cardiac arrest have lower survival rates, when resuscitation performance is low. In In-hospital settings the first responders on scene are usually nursing staff without rhythm analysing skills. In such cases Automated External Defibrillators (AED) might help guiding resuscitation performance. At the Wuerzburg University Hospital (Germany) an AED-program was initiated in 2007. Aim of the presented study was to monitor the impact of Automated External Defibrillators on the management of in-hospital cardiac arrest events. Methods The data acquisition was part of a continuous quality improvement process of the Wuerzburg University Hospital. For analysing the CPR performance, the chest compression rate (CCR), compression depth (CCD), the no flow fraction (NFF), time interval from AED-activation to the first compression (TtC), the time interval from AED-activation to the first shock (TtS) and the post schock pause (TtCS) were determined by AED captured data. A questionnaire was completed by the first responders. Results From 2010 to 2012 there were 359 emergency calls. From these 53 were cardiac arrests with an AED-application. Complete data were available in 46 cases. The TtC was 34 (32–52) seconds (median and IQR).The TtS was 30 (28–32) seconds (median and IQR) . The TtCS was 4 (3–6) seconds (median and IQR) . The CCD was 5.5 ± 1 cm while the CCR was 107 ± 11/min. The NFF was calculated as 41 %. ROSC was achieved in 21 patients (45 %), 8 patients (17 %) died on scene and 17 patients (37 %) were transferred under ongoing CPR to an Intensive Care Unit (ICU). Conclusion The TtS and TtC indicate that there is an AED-user dependent time loss. These time intervals can be markedly reduced, when the user is trained to interrupt the AED’s “chain of advices” by placing the electrode-paddles immediately on the patient’s thorax. At this time the AED switches directly to the analysing mode. Intensive training and adaption of the training contents is needed to optimize the handling of the AED in order to maximize its advantages and to minimize its disadvantages. KW - cardio-pulmonary resuscitation KW - team-training KW - chest-compression rate KW - automated external defibrillators KW - in-hospital cardiac arrest Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-125756 VL - 23 IS - 87 ER - TY - JOUR A1 - Yu, Leo A1 - Natarajan, Chandra M. A1 - Horikiri, Tomoyuki A1 - Langrock, Carsten A1 - Pelc, Jason S. A1 - Tanner, Michael G. A1 - Abe, Eisuke A1 - Maier, Sebastian A1 - Schneider, Christian A1 - Höfling, Sven A1 - Kamp, Martin A1 - Hadfield, Robert H. A1 - Fejer, Martin M. A1 - Yamamoto, Yoshihisa T1 - Two-photon interference at telecom wavelengths for time-bin-encoded single photons from quantum-dot spin qubits JF - Nature Communications N2 - Practical quantum communication between remote quantum memories rely on single photons at telecom wavelengths. Although spin-photon entanglement has been demonstrated in atomic and solid-state qubit systems, the produced single photons at short wavelengths and with polarization encoding are not suitable for long-distance communication, because they suffer from high propagation loss and depolarization in optical fibres. Establishing entanglement between remote quantum nodes would further require the photons generated from separate nodes to be indistinguishable. Here, we report the observation of correlations between a quantum-dot spin and a telecom single photon across a 2-km fibre channel based on time-bin encoding and background-free frequency downconversion. The downconverted photon at telecom wavelengths exhibits two-photon interference with another photon from an independent source, achieving a mean wavepacket overlap of greater than 0.89 despite their original wavelength mismatch (900 and 911 nm). The quantum-networking operations that we demonstrate will enable practical communication between solid-state spin qubits across long distances. KW - atom KW - 1550 nm KW - up-conversion KW - heralded entanglement KW - emission KW - interface KW - generation KW - communication KW - downconversion Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-138677 VL - 6 ER - TY - JOUR A1 - Lee, Chang-Min A1 - Lim, Hee-Jin A1 - Schneider, Christian A1 - Maier, Sebastian A1 - Höfling, Sven A1 - Kamp, Martin A1 - Lee, Yong-Hee T1 - Efficient single photon source based on \(\mu\)-fibre-coupled tunable microcavity JF - Scientific Reports N2 - Efficient and fast on-demand single photon sources have been sought after as critical components of quantum information science. We report an efficient and tunable single photon source based on an InAs quantum dot (QD) embedded in a photonic crystal cavity coupled with a highly curved \(\mu\)-fibre. Exploiting evanescent coupling between the \(\mu\)-fibre and the cavity, a high collection efficiency of 23% and Purcell-enhanced spontaneous emissions are observed. In our scheme, the spectral position of a resonance can be tuned by as much as 1.5 nm by adjusting the contact position of the \(\mu\)-fibre, which increases the spectral coupling probability between the QD and the cavity mode. Taking advantage of the high photon count rate and the tunability, the collection efficiencies and the decay rates are systematically investigated as a function of the QD-cavity detuning. KW - tapers KW - semiconductor quantum dots KW - crystal KW - nanowire KW - generation KW - nanoactivity KW - mode KW - emission Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-145835 VL - 5 IS - 14309 ER - TY - JOUR A1 - Maier, Sebastian A1 - Gold, Peter A1 - Forchel, Alfred A1 - Gregersen, Niels A1 - Mork, Jesper A1 - Höfling, Sven A1 - Schneider, Christian A1 - Kamp, Martin T1 - Bright single photon source based on self-aligned quantum dot-cavity systems JF - Optics Express N2 - We report on a quasi-planar quantum-dot-based single-photon source that shows an unprecedented high extraction efficiency of 42% without complex photonic resonator geometries or post-growth nanofabrication. This very high efficiency originates from the coupling of the photons emitted by a quantum dot to a Gaussian shaped nanohill defect that naturally arises during epitaxial growth in a self-aligned manner. We investigate the morphology of these defects and characterize the photonic operation mechanism. Our results show that these naturally arising coupled quantum dot-defects provide a new avenue for efficient (up to 42% demonstrated) and pure (g(2)(0) value of 0.023) single-photon emission. KW - photon statistics KW - quantum communications KW - resonators KW - quantum-well -wire and -dot devices Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-119801 SN - 1094-4087 VL - 22 IS - 7 ER - TY - JOUR A1 - Elias, Johannes A1 - Heuschmann, Peter U. A1 - Schmitt, Corinna A1 - Eckhardt, Frithjof A1 - Boehm, Hartmut A1 - Maier, Sebastian A1 - Kolb-Mäurer, Annette A1 - Riedmiller, Hubertus A1 - Müllges, Wolfgang A1 - Weisser, Christoph A1 - Wunder, Christian A1 - Frosch, Matthias A1 - Vogel, Ulrich T1 - Prevalence dependent calibration of a predictive model for nasal carriage of methicillin-resistant Staphylococcus aureus JF - BMC Infectious Diseases N2 - Background Published models predicting nasal colonization with Methicillin-resistant Staphylococcus aureus among hospital admissions predominantly focus on separation of carriers from non-carriers and are frequently evaluated using measures of discrimination. In contrast, accurate estimation of carriage probability, which may inform decisions regarding treatment and infection control, is rarely assessed. Furthermore, no published models adjust for MRSA prevalence. Methods Using logistic regression, a scoring system (values from 0 to 200) predicting nasal carriage of MRSA was created using a derivation cohort of 3091 individuals admitted to a European tertiary referral center between July 2007 and March 2008. The expected positive predictive value of a rapid diagnostic test (GeneOhm, Becton & Dickinson Co.) was modeled using non-linear regression according to score. Models were validated on a second cohort from the same hospital consisting of 2043 patients admitted between August 2008 and January 2012. Our suggested correction score for prevalence was proportional to the log-transformed odds ratio between cohorts. Calibration before and after correction, i.e. accurate classification into arbitrary strata, was assessed with the Hosmer-Lemeshow-Test. Results Treating culture as reference, the rapid diagnostic test had positive predictive values of 64.8% and 54.0% in derivation and internal validation corhorts with prevalences of 2.3% and 1.7%, respectively. In addition to low prevalence, low positive predictive values were due to high proportion (> 66%) of mecA-negative Staphylococcus aureus among false positive results. Age, nursing home residence, admission through the medical emergency department, and ICD-10-GM admission diagnoses starting with “A” or “J” were associated with MRSA carriage and were thus included in the scoring system, which showed good calibration in predicting probability of carriage and the rapid diagnostic test’s expected positive predictive value. Calibration for both probability of carriage and expected positive predictive value in the internal validation cohort was improved by applying the correction score. Conclusions Given a set of patient parameters, the presented models accurately predict a) probability of nasal carriage of MRSA and b) a rapid diagnostic test’s expected positive predictive value. While the former can inform decisions regarding empiric antibiotic treatment and infection control, the latter can influence choice of screening method. KW - Methicillin-resistant staphylococcus aureus KW - Infection control KW - Clinical prediction rule KW - Predictive value of tests KW - False positive reactions KW - Calibration Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-96091 UR - http://www.biomedcentral.com/1471-2334/13/111 ER -