TY - JOUR A1 - Verma, Shwetabh A1 - Kehrer, Tobias A1 - Hesser, Jürgen A1 - Arba Mosquera, Samuel T1 - Analysis of Impact of Humidity and Temperature on Excimer Laser Ablation of Polyethylene Terephthalate, Polymethylmethacrylate, and Porcine Corneal Tissue JF - Lasers in Surgery and Medicine N2 - Background and Objectives To analyze the impact of humidity and temperature on excimer laser ablation of polyethylene terephthalate (PET), polymethylmethacrylate (PMMA) and porcine corneal tissue, and an ablation model to compensate for the temperature and humidity changes on ablation efficiency. Study Design/Materials and Methods The study was conducted using an AMARIS 1050RS (Schwind eye‐tech‐solutions) placed inside a climate chamber at ACTS. Ablations were performed on PET, PMMA, and porcine cornea. The impact of a wide range of temperature (~18°C to ~30°C) and relative humidity (~25% to ~80%) on laser ablation outcomes was tested using nine climate test settings. For porcine eyes, change in defocus was calculated from the difference of post‐ablation to pre‐ablation average keratometry readings. Laser scanning deflectometry was performed to measure refractive change achieved in PMMA. Multiple linear regression was performed using the least square method with predictive factors: temperature, relative humidity, time stamp. Influence of climate settings was modeled for pulse energy, pulse fluence, ablation efficiency on PMMA and porcine cornea tissue. Results Temperature changes did not affect laser pulse energy, pulse fluence (PET), and ablation efficiency (on PMMA or porcine corneal tissue) significantly. Changes in relative humidity were critical and significantly affected laser pulse energy, high fluence and low fluence. The opposite trend was observed between the ablation performance on PMMA and porcine cornea. Conclusions The proposed well‐fitting multi‐linear model can be utilized for compensation of temperature and humidity changes on ablation efficiency. Based on this model, a working window for optimum operation has been found (temperature 18°C to 28°C and relative humidity 25% to 65%) for a maximum deviation of ±2.5% in ablation efficiency in PMMA and porcine corneal tissue. KW - impact of humidity and temperature KW - excimer laser ablation KW - PMMA KW - cornea KW - PET KW - refractive surgery Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-213395 VL - 52 IS - 7 SP - 627 EP - 638 ER - TY - JOUR A1 - von Hertzberg-Boelch, Sebastian Philipp A1 - Luedemann, Martin A1 - Rudert, Maximilian A1 - Steinert, Andre F. T1 - PMMA bone cement: antibiotic elution and mechanical properties in the context of clinical use JF - Biomedicines N2 - This literature review discusses the use of antibiotic loaded polymethylmethacrylate bone cements in arthroplasty. The clinically relevant differences that have to be considered when antibiotic loaded bone cements (ALBC) are used either for long-term implant fixation or as spacers for the treatment of periprosthetic joint infections are outlined. In this context, in vitro findings for antibiotic elution and material properties are summarized and transferred to clinical use. KW - spacer KW - bone cement KW - PMMA KW - polymethylmethacrylate KW - periprosthetic infection KW - antibiotic elution Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-281708 SN - 2227-9059 VL - 10 IS - 8 ER -