TY - JOUR A1 - Zinner, Christoph A1 - Hauser, Anna A1 - Born, Dennis-Peter A1 - Wehrlin, Jon P. A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Influence of Hypoxic Interval Training and Hyperoxic Recovery on Muscle Activation and Oxygenation in Connection with Double-Poling Exercise JF - PLoS One N2 - Here, we evaluated the influence of breathing oxygen at different partial pressures during recovery from exercise on performance at sea-level and a simulated altitude of 1800 m, as reflected in activation of different upper body muscles, and oxygenation of the m. triceps brachii. Ten well-trained, male endurance athletes (25.3±4.1 yrs; 179.2±4.5 cm; 74.2±3.4 kg) performed four test trials, each involving three 3-min sessions on a double-poling ergometer with 3-min intervals of recovery. One trial was conducted entirely under normoxic (No) and another under hypoxic conditions \((Ho; F_iO_2 = 0.165)\). In the third and fourth trials, the exercise was performed in normoxia and hypoxia, respectively, with hyperoxic recovery \((HOX; F_iO_2 = 1.00)\) in both cases. Arterial hemoglobin saturation was higher under the two HOX conditions than without HOX (p<0.05). Integrated muscle electrical activity was not influenced by the oxygen content (best d = 0.51). Furthermore, the only difference in tissue saturation index measured via near-infrared spectroscopy observed was between the recovery periods during the NoNo and HoHOX interventions (P<0.05, d = 0.93). In the case of HoHo the athletes’ \(P_{mean}\) declined from the first to the third interval (P < 0.05), whereas Pmean was unaltered under the HoHOX, NoHOX and NoNo conditions. We conclude that the less pronounced decline in \(P_{mean}\) during 3 x 3-min double-poling sprints in normoxia and hypoxia with hyperoxic recovery is not related to changes in muscle activity or oxygenation. Moreover, we conclude that hyperoxia \((F_iO_2 = 1.00)\) used in conjunction with hypoxic or normoxic work intervals may serve as an effective aid when inhaled during the subsequent recovery intervals. KW - triceps KW - bood KW - medical hypoxia KW - blood KW - arms KW - hyperoxia KW - breathing KW - near-infrared spectroscopy Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126299 VL - 10 IS - 10 ER - TY - JOUR A1 - Zinner, Christoph A1 - Sperlich, Billy A1 - Wahl, Patrick A1 - Mester, Joachim T1 - Classification of selected cardiopulmonary variables of elite athletes of different age, gender, and disciplines during incremental exercise testing JF - SpringerPlus N2 - Incremental exercise testing is frequently used as a tool for evaluating determinants of endurance performance. The available reference values for the peak oxygen uptake \((VO_{2peak})\), % of \(VO_{2peak}\) , running speed at the lactate threshold \((v_{LT})\), running economy (RE), and maximal running speed \((v_{peak})\) for different age, gender, and disciplines are not sufficient for the elite athletic population. The key variables of 491 young athletes (age range 12–21 years; 250 males, 241 females) assessed during a running step test protocol \((2.4 m s^{−1} ; increase 0.4 m s^{−1} 5 min^{−1})\) were analysed in five subgroups, which were related to combat-, team-, endurance-, sprint- and power-, and racquet-related disciplines. Compared with female athletes, male athletes achieved a higher \(v_{peak}\) (P = 0.004). The body mass, lean body mass, height, abs. \(VO_{2peak} (ml min^{−1})\), rel. \(VO_{2peak} (ml kg^{−1} min^{−1})\), rel. \(VO_{2peak} (ml min^{−1} kg^{−0.75})\), and RE were higher in the male participants compared with the females (P < 0.01). The % of \(VO_2\) at \(v_{LT}\) was lower in the males compared with the females (P < 0.01). No differences between gender were detected for the \(v_{LT}\) (P = 0.17) and % of \(VO_2\) at \(v_{LT}\) (P = 0.42). This study is one of the first to provide a broad spectrum of data to classify nearly 500 elite athletes aged 12–21 years of both gender and different disciplines. KW - performance KW - data KW - competition KW - reference values Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126275 VL - 4 IS - 544 ER - TY - JOUR A1 - Stöggl, Thomas A1 - Sperlich, Billy T1 - Polarized training has greater impact on key endurance variables than threshold, high intensity, or high volume training JF - Frontiers in Physiology N2 - Endurance athletes integrate four conditioning concepts in their training programs: high-volume training (HVT), “threshold-training” (THR), high-intensity interval training (HIIT) and a combination of these aforementioned concepts known as polarized training (POL). The purpose of this study was to explore which of these four training concepts provides the greatest response on key components of endurance performance in well-trained endurance athletes. Methods: Forty eight runners, cyclists, triathletes, and cross-country skiers (peak oxygen uptake: (VO2peak): 62.6 ± 7.1 mL·min−1·kg−1) were randomly assigned to one of four groups performing over 9 weeks. An incremental test, work economy and a VO2peak tests were performed. Training intensity was heart rate controlled. Results: POL demonstrated the greatest increase in VO2peak (+6.8 ml·min·kg−1 or 11.7%, P < 0.001), time to exhaustion during the ramp protocol (+17.4%, P < 0.001) and peak velocity/power (+5.1%, P < 0.01). Velocity/power at 4 mmol·L−1 increased after POL (+8.1%, P < 0.01) and HIIT (+5.6%, P < 0.05). No differences in pre- to post-changes of work economy were found between the groups. Body mass was reduced by 3.7% (P < 0.001) following HIIT, with no changes in the other groups. With the exception of slight improvements in work economy in THR, both HVT and THR had no further effects on measured variables of endurance performance (P > 0.05). Conclusion: POL resulted in the greatest improvements in most key variables of endurance performance in well-trained endurance athletes. THR or HVT did not lead to further improvements in performance related variables. KW - work economy KW - time to exhaustion KW - peak oxygen uptake KW - peak power KW - lactate threshold Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-117007 VL - 5 IS - 33 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Holmberg, Hans-Christer A1 - Goernert, Florian A1 - Sperlich, Billy T1 - A novel compression garment with adhesive silicone stripes improves repeated sprint performance – a multi-experimental approach on the underlying mechanisms JF - BMC Sports Science, Medicine and Rehabilitation N2 - Background Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors. Methods In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12). Results In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered. Conclusion Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique. KW - tissue saturation index KW - blood flow KW - clothing KW - oscillation KW - oxygenation KW - oxygen uptake KW - textile KW - venous system KW - video analysis Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-116995 UR - http://www.biomedcentral.com/2052-1847/6/21 VL - 6 IS - 21 ER -