TY - THES A1 - Bleuel, Gabriel T1 - Entwicklung und Validierung eines quantitativen Verfahrens zur Beurteilung der Viabilität von entsprechend der GMP-Richtlinien hergestellter Knorpelimplantate für das Knie T1 - Development and validation of a quantitative assay for a viability test of cultivated knee cartilage implants N2 - Due to the reversing age pyramid in Germany, more and more people are already suffering from joint cartilage damage. But not only age, but also accidents and sports injuries and being overweight can lead to irreversible cartilage defects. Although there are various treatment options, the previous methods cannot be considered a permanent cure. As part of the international research project BIO-CHIP, a promising treatment method with novel drugs was to be investigated. The patient's own cartilage cells from the nose serve as the starting material for the drug, a manufactured cartilage implant. These are isolated, multiplied and ultimately cultivated on a matrix to form a cartilage implant. In addition to toxicological and biological safety tests, an essential prerequisite for the approval of the implant is the assessment of the viability. This was previously carried out on the basis of histology from the pathology department. The aim of the present work was the development and validation of a standardized and objective viability test for the chondrocytes within the cartilage matrix. For this, the LDH was used as a marker for irreversibly damaged cells. The LDH concentration could be measured with the CyQuant LDH assay by measuring the absorption. It could be proven that LDH has the required stability and detectability in the medium. With the help of the lysis, of cultivated mini-cartilage implants, the maximum achievable LDH concentrations could be determined. A calibration curve was generated using these concentrations. This serves to assess the viability of future measured absorptions of the supernatant medium. The developed method does not require any invasive interventions on the implant and is characterized by its simple implementation, since only the protrusion has to be measured. The validation of the method certified a high level of robustness, linearity, accuracy and precision. N2 - Aufgrund der sich umkehrenden Alterspyramide in Deutschland leiden bereits jetzt immer mehr Menschen an Gelenkknorpelschäden. Doch nicht nur das Alter, sondern auch Unfälle und Sportverletzungen und Übergewicht können zu irreversiblen Knorpeldefekten führen. Obwohl es diverse Behandlungsmöglichkeiten gibt, können die bisherige Methoden nicht als dauerhafte Heilung betrachtet werden. Im Rahmen des internationalen Forschungsprojektes BIO-CHIP sollte eine vielsprechende Behandlungsmethode mit neuartigen Arzneimitteln untersucht werden. Als Ausgangsmaterial des Arzneimittels, ein hergestelltes Knorpelimplantat, dienen patienteneigene Knorpelzellen aus der Nase. Diese werden isoliert, vermehrt und letztlich auf einer Matrix zu einem Knorpelimplantat kultiviert. Wesentliche Voraussetzung für die Implantatfreigabe stellt neben toxikologischen und biologischen Unbedenklichkeitstests die Beurteilung der Viabilität dar. Diese wurde bisher anhand von Histologieschnitten von der Pathologie durchgeführt. Ziel der vorliegenden Arbeit war die Entwicklung und Validierung eines standardisierten und objektiven Viabilitätstests für die Chondrozyten innerhalb der Knorpelmatrix. Hierfür wurde die LDH als Marker für irreversibel geschädigte Zellen verwendet. Die LDH Konzentration konnte mit dem CyQuant LDH-Assay durch die Messung der Absorption gemessen werden. Es konnte nachgewiesen werden, dass LDH die erforderliche Stabilität und Nachweisbarkeit im Medium besitzt. Mithilfe der Lyse, analog zum Herstellungsprozess, gezüchteter Mini-Knorpelimplantate, konnten die maximal erreichbaren LDH Konzentrationen ermittelt werden. Mithilfe dieser Konzentrationen wurde eine Eichkurve generiert. Diese dient als Beurteilung der Viabilität zukünftig gemessener Absorptionen des Überstandmediums. Das entwickelte Verfahren erfordert keine invasiven Eingriffe am Implantat und zeichnet sich durch eine einfache Durchführung aus, da nur der Überstand gemessen werden muss. Die durchgeführte Validierung der Methode bescheinigte eine hohe Robustheit, Linearität, Genauigkeit und Präzision. KW - Hyaliner Knorpel KW - Lactatdehydrogenase KW - Kniegelenk KW - Zellkultur KW - Entwicklung KW - development KW - Validierung KW - LDH-assay KW - Knorpelimplantate KW - validation KW - cartilage Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-242481 ER - TY - JOUR A1 - Mayr, Stefan A1 - Klein, Igor A1 - Rutzinger, Martin A1 - Kuenzer, Claudia T1 - Determining temporal uncertainty of a global inland surface water time series JF - Remote Sensing N2 - Earth observation time series are well suited to monitor global surface dynamics. However, data products that are aimed at assessing large-area dynamics with a high temporal resolution often face various error sources (e.g., retrieval errors, sampling errors) in their acquisition chain. Addressing uncertainties in a spatiotemporal consistent manner is challenging, as extensive high-quality validation data is typically scarce. Here we propose a new method that utilizes time series inherent information to assess the temporal interpolation uncertainty of time series datasets. For this, we utilized data from the DLR-DFD Global WaterPack (GWP), which provides daily information on global inland surface water. As the time series is primarily based on optical MODIS (Moderate Resolution Imaging Spectroradiometer) images, the requirement of data gap interpolation due to clouds constitutes the main uncertainty source of the product. With a focus on different temporal and spatial characteristics of surface water dynamics, seven auxiliary layers were derived. Each layer provides probability and reliability estimates regarding water observations at pixel-level. This enables the quantification of uncertainty corresponding to the full spatiotemporal range of the product. Furthermore, the ability of temporal layers to approximate unknown pixel states was evaluated for stratified artificial gaps, which were introduced into the original time series of four climatologic diverse test regions. Results show that uncertainty is quantified accurately (>90%), consequently enhancing the product's quality with respect to its use for modeling and the geoscientific community. KW - Earth observation KW - interpolation KW - MODIS KW - optical remote sensing KW - probability KW - reliability KW - validation KW - variability Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-245234 SN - 2072-4292 VL - 13 IS - 17 ER - TY - JOUR A1 - Reiners, Philipp A1 - Asam, Sarah A1 - Frey, Corinne A1 - Holzwarth, Stefanie A1 - Bachmann, Martin A1 - Sobrino, Jose A1 - Göttsche, Frank-M. A1 - Bendix, Jörg A1 - Kuenzer, Claudia T1 - Validation of AVHRR Land Surface Temperature with MODIS and in situ LST — a TIMELINE thematic processor JF - Remote Sensing N2 - Land Surface Temperature (LST) is an important parameter for tracing the impact of changing climatic conditions on our environment. Describing the interface between long- and shortwave radiation fluxes, as well as between turbulent heat fluxes and the ground heat flux, LST plays a crucial role in the global heat balance. Satellite-derived LST is an indispensable tool for monitoring these changes consistently over large areas and for long time periods. Data from the AVHRR (Advanced Very High-Resolution Radiometer) sensors have been available since the early 1980s. In the TIMELINE project, LST is derived for the entire operating period of AVHRR sensors over Europe at a 1 km spatial resolution. In this study, we present the validation results for the TIMELINE AVHRR daytime LST. The validation approach consists of an assessment of the temporal consistency of the AVHRR LST time series, an inter-comparison between AVHRR LST and in situ LST, and a comparison of the AVHRR LST product with concurrent MODIS (Moderate Resolution Imaging Spectroradiometer) LST. The results indicate the successful derivation of stable LST time series from multi-decadal AVHRR data. The validation results were investigated regarding different LST, TCWV and VA, as well as land cover classes. The comparisons between the TIMELINE LST product and the reference datasets show seasonal and land cover-related patterns. The LST level was found to be the most determinative factor of the error. On average, an absolute deviation of the AVHRR LST by 1.83 K from in situ LST, as well as a difference of 2.34 K from the MODIS product, was observed. KW - Land Surface Temperature KW - AVHRR KW - MODIS KW - time series KW - Europe KW - validation KW - TIMELINE Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-246051 SN - 2072-4292 VL - 13 IS - 17 ER - TY - JOUR A1 - Szymski, Dominik A1 - Aschenbach, Leonard A1 - Krutsch, Volker A1 - Alt, Volker A1 - Meffert, Rainer A1 - Krutsch, Werner A1 - Fehske, Kai T1 - Injury epidemiology in men's professional team sports: is media analysis helpful? JF - Archives of Orthopaedic and Trauma Surgery N2 - Introduction Epidemiological injury surveillance in professional sports is often based on online media analysis in order to collect necessary data. However, the validation of this study protocol is lacking. Therefore, this study aimed to identify the validity of injury surveillance in men's professional team sports based on media reports. Methods In a retrospective cohort study, the validity of media-data-relating injuries was investigated in participating teams of the highest two German divisions in men's professional basketball (BB) and handball (HB) in the season 2018/2019. Injury protocols completed by the team physicians were compared to those of sports media injury reports. Results The study population was composed of 133 athletes (54 BB and 79 HB). Of 343 injuries reported by the team physicians, 151 (44%) could be identified by means of sports media reports. Severe injuries (n = 75, 72%) were reported more likely in sports media compared to less severe injuries (n = 76, 32%, p < 0.00001). Odds ratio (OR) was 5.33 (95% CI 3.22-8.82). No differences regarding injury reporting could be seen between the two team sports. Conclusion For severe injuries, media analysis may be a sufficient method for data collection in popular men's professional ball sports. An underestimation of true injury prevalence lies within the range of previous reported investigations concerning the validation of injury surveillance methods. Non-severe injuries could not be verified via media analysis in professional handball and basketball. KW - severe injury KW - professional KW - injury KW - media-based KW - evidence KW - validation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-266690 SN - 1434-3916 VL - 141 IS - 4 ER - TY - JOUR A1 - Urlaub, Jonas A1 - Kaiser, Reinhard P. A1 - Scherf‐Clavel, Oliver A1 - Bolm, Carsten A1 - Holzgrabe, Ulrike T1 - Investigation of isomerization of dexibuprofen in a ball mill using chiral capillary electrophoresis JF - Electrophoresis N2 - Besides the racemate, the S‐enantiomer of ibuprofen (Ibu) is used for the treatment of inflammation and pain. Since the configurational stability of S‐Ibu in solid state is of interest, it was studied by means of ball milling experiments. For the evaluation of the enantiomeric composition, a chiral CE method was developed and validated according to the ICH guideline Q2(R1). The addition of Mg\(^{2+}\), Ca\(^{2+}\), or Zn\(^{2+}\) ions to the background electrolyte (BGE) was found to improve Ibu enantioresolution. Chiral separation of Ibu enantiomers was achieved on a 60.2 cm (50.0 cm effective length) x 75 μm fused‐silica capillary using a background electrolyte (BGE) composed of 50 mM sodium acetate, 10 mM magnesium acetate tetrahydrate, and 35 mM heptakis‐(2,3,6‐tri‐O‐methyl)‐β‐cyclodextrin (TM‐β‐CD) as chiral selector. The quantification of R‐Ibu in the mixture was performed using the normalization procedure. Linearity was evaluated in the range of 0.68–5.49% R‐Ibu (R\(^{2}\) = 0.999), recovery was found to range between 97 and 103%, the RSD of intra‐ and interday precision below 2.5%, and the limit of quantification for R‐ in S‐Ibu was calculated to be 0.21% (extrapolated) and 0.15% (dilution of racemic ibuprofen), respectively. Isomerization of S‐Ibu was observed under basic conditions by applying long milling times and high milling frequencies. KW - capillary electrophoresis KW - chiral separation KW - Ibuprofen KW - isomerization KW - validation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-225852 VL - 42 IS - 17-18 SP - 1790 EP - 1799 ER -