TY - THES A1 - Wohlfart, Jonas T1 - Analysis of Drug Impurities by Means of Chromatographic Methods: Targeted and Untargeted Approaches T1 - Analytik von Verunreinigungen in Arzneimitteln mittels chromatographischer Methoden: Gerichtete und ungerichtete Ansätze N2 - The presented works aimed on the analysis of new impurities in APIs and medicinal products. Different subtypes of LC were coupled to suitable detection methods, i.e. UV and various MS techniques, depending on the chemical natures of the analytes and the analytical task. Unexpected impurities in medicinal products and APIs caused several scandals in the past, concomitant with fatalities or severe side effects in human and veterinary patients. The detection of nitrosamines in sartans led to the discovery of nitrosamines in various other drugs, of which the antibiotic rifampicin was analyzed in this work. An examination of the synthesis of rifampicin revealed a high potential for the formation of 4-methyl-1-nitrosopiperazine (MeNP). An LC-MS/HRMS method suitable for the quantification of MeNP was applied in the analysis of drugs collected from Brazil, Comoros, India, Nepal, and Tanzania, where a single dose of rifampicin is used in the post-exposure prophylaxis of leprosy. All batches were contaminated with MeNP, ranging from 0.7-5.1 ppm. However, application of rifampicin containing up to 5 ppm MeNP was recommended by the regulatory authorities for the post-exposure prophylaxis of leprosy. In the 1990s the aminoglycoside antibiotic gentamicin attracted attention after causing fatalities in the USA, but the causative agent was never identified unequivocally. The related substance sisomicin was recognized as a lead impurity by the Holzgrabe lab at the University of Würzburg: sisomicin was accompanied by a variety of other impurities and batches containing sisomicin had caused the fatalities. In 2016, anaphylactic reactions were reported after application of gentamicin. A contamination of the medicinal products with histamine, an impurity of the raw material fish peptone used upon the production, could be identified as the cause of the adverse effects. Batches of gentamicin sulfate, which had been stored at the University of Würzburg since the earlier investigations, were analyzed regarding their contamination with histamine to determine whether the biogenic amine was responsible for the 1990s fatalities as well. Furthermore, a correlation with the lead impurity sisomicin was checked. Histamine could be detected in all analyzed batches, but at a lower level than in the batches responsible for the anaphylactic reactions. Moreover, there is no correlation of histamine with the lead impurity sisomicin. Hence, the causative agent for the 1990s fatalities was not histamine and remains unknown. Another source of impurities is the reaction of APIs with excipients, e.g. the esterification of naproxen with PEG 600 in soft gel capsules. The influence of the formulation’s composition on this reaction was investigated by means of LC-UV. Therefore, the impurity naproxen-PEG-ester (NPEG) was synthesized and used for the development of a method suitable for the analysis of soft gel capsule formulations. Different formulations were stressed for 7 d at 60 °C and the relative amount of NPEG was determined. The formation of NPEG was influenced by the concentrations of water and lactic acid, the pH, and the drug load of the formulation, which can easily be explained by the chemistry behind esterification reactions. Keeping in mind the huge variety of sources of impurities, it might be impossible to predict all potential impurities of a drug substance/product. Targeted and untargeted approaches were combined in the impurity profiling of bisoprolol fumarate. Eight versions of an LC-HRMS method were developed to enable the detection of a maximum number of impurities: an acidic and a basic buffered LC was coupled to MS detection applying ESI and APCI, both in positive in negative mode. MS and MS/MS data were acquired simultaneously by information dependent acquisition. In the targeted approach, potential impurities were derived from a reaction matrix based on the synthesis route of the API, while the untargeted part was based on general unknown comparative screening to identify additional signals. 18 and 17 impurities were detected in the targeted and the untargeted approach, respectively. The molecular formulae were assessed based on the exact mass and the isotope pattern. Theoretical fragment spectra generated by in silico fragmentation were matched with experimental data to estimate the plausibility of proposed/elucidated structures. Moreover, the detected impurities were quantified with respect to an internal standard. N2 - In den vorgestellten Projekten wurden neue Verunreinigungen in Arzneistoffen und Arzneimitteln untersucht. Verschiedene flüssigchromatographische Methoden wurden mit geeigneten Detektionsverfahren gekoppelt. UV-Detektion und verschiedene massenspektrometrische Techniken wurden in Abhängigkeit der chemischen Eigenschaften der Analyten und der analytischen Herausforderung ausgewählt. Eine Kontamination von Wirkstoffen bzw. humanen und veterinären Arzneimittel mit unerwarteten Verunreinigungen löste mehrere Skandale aus, die mit Todesfällen oder ernsthaften Nebenwirkungen einhergingen. Die Identifikation von Nitrosamin-Verunreinigungen in Sartanen führte zur Entdeckung von Nitrosaminen in verschiedenen anderen Wirkstoffen, z.B. im Antibiotikum Rifampicin, das in dieser Arbeit untersucht wurde. Eine Betrachtung der Rifampicin-Synthese offenbarte ein hohes Potenzial der Bildung von 4-Methyl-1-nitrosopiperazin (MeNP). Arzneimittel aus Brasilien, Indien, Nepal, Tansania und von den Komoren wurden mittels LC-MS/HRMS bezüglich ihres MeNP-Gehaltes analysiert. Alle untersuchten Chargen waren mit MeNP im Bereich von 0.7-5.1 ppm belastet. Rifampicin wird in den genannten Ländern unter anderem als Einzeldosis zur Postexpositionsprophylaxe von Lepra eingesetzt. Für diese Indikation empfehlen die Zulassungsbehörden die Verwendung von Rifampicin mit bis zu 5 ppm MeNP. Das Aminoglycosid-Antibiotikum Gentamicin löste in den 1990er Jahren Todesfälle in den USA aus. Die verantwortliche Verunreinigung wurde nie eindeutig aufgeklärt, doch die verwandte Substanz Sisomicin wurde durch den Arbeitskreis Holzgrabe an der Universität Würzburg als Leitverunreinigung identifiziert: Sisomicin ging mit einer Vielzahl von weiteren Verunreinigungen einher und Sisomicin-reiche Chargen hatten die Todesfälle ausgelöst. 2016 traten anaphylaktische Reaktionen nach Gentamicin-Anwendung auf. Histamin war als Verunreinigung von Fischpepton, einem Ausgangsmaterial der Produktion, in den Wirkstoff gelangt. Um zu überprüfen, ob Histamin auch für die Todesfälle in den 1990er Jahren verantwortlich war, wurden seit den früheren Untersuchungen gelagerte Gentamicin-Chargen bezüglich ihrer Verunreinigung mit Histamin untersucht. Außerdem wurde überprüft, ob es einen Zusammenhang mit dem Sisomicin-Gehalt gibt. In allen untersuchten Proben wurde Histamin gefunden, allerdings in einer geringeren Konzentration als in Chargen, die anaphylaktische Reaktionen ausgelöst hatten. Des Weiteren konnte kein Zusammenhang mit der Leitverunreinigung Sisomicin erkannt werden. Der Auslöser der Todesfälle in den 1990er Jahren war somit nicht Histamin, sondern bleibt weiterhin unbekannt. Ein weiterer Ursprung von Verunreinigungen ist die Reaktion des Wirkstoffs mit Hilfsstoff(en), z.B. die Veresterung von Naproxen mit PEG in Weichkapseln. Der Einfluss von Veränderungen der Formulierung auf diese Reaktion wurde mittels LC-UV untersucht. Die Verunreinigung Naproxen-PEG-Ester (NPEG) wurde synthetisiert und zur Entwicklung einer Methode zur Analyse von Weichkapsel-Formulierungen verwendet. Verschiedene Formulierungen wurden für 7 Tage bei 60 °C gestresst und deren relative Gehalte an NPEG bestimmt. Dabei war die Bildung von NPEG von der Wasser- und der Milchsäure-Konzentration, dem pH und dem Wirkstoffgehalt der Formulierung abhängig. Sämtliche Einflüsse konnten durch die Art der Reaktion (Veresterung) erklärt werden. Vor dem Hintergrund der vielfältigen Quellen für Verunreinigungen erscheint es unmöglich, alle potenziellen Verunreinigungen eines Wirkstoffs/Arzneimittels vorherzusagen. Gerichtete und ungerichtete Ansätze wurden daher für die Erstellung eines Verunreinigungsprofils von Bisoprololfumarat kombiniert. Um eine möglichst große Anzahl von möglichen Substanzen zu detektieren, wurden 8 LC-MS/HRMS-Methoden entwickelt: je eine saure und eine basische mobile Phase der LC wurde mit massenspektrometrischer Detektion mittels ESI und APCI, jeweils im positiv- und negativ-Modus kombiniert. MS- und MS/MS-Daten wurden simultan durch information dependent acquisition aufgenommen. Für den gerichteten Ansatz wurde eine Reaktionsmatrix auf Basis der Synthese des Wirkstoffs angefertigt und ausgehend davon potenzielle Verunreinigungen abgeleitet. Im ungerichteten Ansatz wurden mittels general unknown comparative screening zusätzliche Signale identifiziert. Der gerichtete Ansatz zeigte die Anwesenheit von 18, der ungerichtete von 17 Verunreinigungen. Summenformeln wurden anhand der exakten Masse und des Isotopenmusters der Signale bewertet. Die Plausibilität von Strukturformeln wurde mittels In-silico-Fragmentierung abgeschätzt, wobei experimentelle und theoretische Fragmentspektren in Einklang gebracht wurden. Außerdem wurden alle detektierten Verunreinigungen mittels eines externen Standards quantifiziert. KW - LC-MS KW - Gentamicin KW - Naproxen KW - Bisoprolol KW - Rifampicin KW - Impurity Profiling Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-273878 ER - TY - THES A1 - Jakob-Rodamer, Verena T1 - Development and validation of LC-MS/MS methods to determine PK/PD parameters of anti-infectives T1 - Entwicklung und Validierung von LC-MS/MS Methoden zur Bestimmung von PK/PD-Parametern von Antiinfektiva N2 - In the present thesis the development and validation of bioanalytical LC-MS/MS methods for the quantification of erythromycin A, erythromycin ethylsuccinate, roxithromycin, clarithromycin, 14 hydroxy clarithromycin, flucloxacillin, piperacillin and moxifloxacin in human plasma and human urine (piperacillin) is introduced. All methods were applied to analyze human plasma and urine samples from clinical trials and therefore, have been validated according to international guidelines. The methods were reliable in these studies and fulfilled all regulatory requirements known at the time of the study conduct. Moreover, the validation data of the macrolides were compared on three different mass spectrometers (API III Plus, API 3000™, API 5000™). The new innovations in the ion source (horizontal versus vertical electrospray), the ionpath (skimmer, QJet) and the diameter of the orifice resulted in better sensitivity and a larger linearity range for the majority of the analytes. Sensitivity was improved up to a factor of 12 (for clarithromycin) between API III Plus to API 3000™ and up to a factor of 8 (for erythromycin and roxithromycin) between API 3000™ and API 5000™, keeping the accuracy and precision data at about the same level. The high sensitivity was a benefit for example for the flucloxacillin study, because concentrations from all subject samples were detectable up to approximately eight half-lives, i.e. no concentrations needed to be reported below the quantification limit. Also the linearity range were extended from two orders of magnitude to up to four orders of magnitude, which increases the likelihood to allow to analyze all samples from a pharmacokinetic study in the same run. This is especially useful if a large concentration range needs to be analysed, for example, if the method shall be applied in an ascending dose study. Then, all low concentrations from the beginning of the study can be determined, as well as all high concentrations, without the need to dilute and analyse single samples repeatedly. The pharmacokinetic data were compared to previously reported literature data and correlated graphically with MIC values of popular microorganisms which might be a starting point for further PK/PD investigations. The PK/PD theory is a very helpful tool for prediction of the efficacy of given drugs against certain micro-organisms. Depending on the pharmacodynamic processes, e. g. the mode of action, three classes of drugs have been identified. In the same way this applies to adverse effects, which need to be minimised by reducing plasma concentrations. These coherences are not well-investigated, yet, and are not discussed further in this thesis. Still, a lot of research has to be done in this interdisciplinary field to minimise uncertainty in single values, like an AUC/MIC. These include: Improve accuracy and precision of bioanalytical methods determining total and free concentration data in biological matrices for calculation of AUC and Cmax These parameters are related to the MIC in pharmacodynamic considerations. Since the determination of the MIC often underlies significant variations and also differences between microbiological laboratories, the determination of concentrations of anti-infectives is particular important, being achievable by scientific exact techniques. Finally, from the volume of distribution of antibiotics can be used to derive information about intracellular concentrations and effectivity of antiinfectives. N2 - In der vorliegenden Arbeit wird die Entwicklung und Validierung von bioanalytischen LC-MS/MS-Methoden zur Quantifizierung von Erythromycin A, Erythromycin-ethylsuccinat, Roxithromycin, Clarithromycin, 14 Hydroxy-clarithromycin, Flucloxacillin, Piperacillin und Moxifloxacin in Humanplasma und Humanurin (Piperacillin) vorgestellt. Alle Methoden wurden für die Analyse von Plasma- und Urinproben aus klinischen Studien beim Menschen eingesetzt und deshalb nach international anerkannten Richtlinien validiert. In diesen Studien haben sich die Methoden bewährt und alle Anforderungen der zum Zeitpunkt der Studie bekannten behördlichen Ansprüche erfüllt. Die Validierungsdaten der Makrolid-Methoden konnten zudem an drei Massenspektrometern der selben Baureihe verglichen werden. Dabei zeigte sich, dass die Neuerungen an der Ionenquelle (horizontale versus vertikale ESI), dem Ionenpfad (Skimmer, QJet), sowie das immer größere Orifice in der Baureihe, nicht nur stetig verbesserte Sensitivität ermöglichen, sondern auch immer größere Linearitätsbereiche. So konnte ein Sensitivitätsgewinn bis zu Faktor 12 (Clarithromycin) von API III Plus auf API 3000™ und bis zu Faktor 8 (Erythromycin und Roxithromycin) von API 3000™ auf API 5000™ bei etwa gleichen Werten für die Präzision erreicht werden. Die hohe Sensitivität zeigte sich zum Beispiel bei der Flucloxacillin Studie von Vorteil, da alle Konzentrationen bis circa acht Halbwertszeiten nach Wirkstoffgabe bestimmt werden konnten, ohne dass einzelne Proben als „BLOQ“ (unter dem Quantifizierungslimit) berichtet werden mussten. Während früher noch Linearitätsbereiche um zwei Größenordnungen üblich waren, sind jetzt am API 5000™ Konzentrationsbereiche über bis zu vier Größenordnungen reproduzierbar linear. Das ist insbesondere von Nutzen, wenn bei einer Substanz ein größerer Konzentrationsbereich gemessen werden muss. Das ist beispielsweise dann der Fall, wenn die Methode für eine Dosissteigerungsstudie eingesetzt werden soll. Dann können sowohl alle kleinen Konzentrationen zu Beginn der Studie gemessen werden, als auch alle hohen Konzentrationen zum Ende der Studie, und zwar ohne, dass einzelne Proben gesondert verdünnt und wiederholt gemessen werden müssen. Die pharmakokinetischen Daten der Antibiotika wurden in den Kontext mit Literaturdaten gestellt und graphisch mit MHK-Werten für gängige Mikroorganismen verglichen, was den Ausgangspunkt für spätere PK/PD-Untersuchungen darstellt. Für die Vorhersage der Wirksamkeit einer verabreichten Substanz gegenüber bestimmten Mikroorganismen ist die PK/PD-Korrelation ein gutes Hilfsmittel. Anhand der pharmakodynamischen Parameter, wie der Wirkungsweise, können drei Antibiotikaklassen gebildet werden. In analoger Weise gilt für die Nebenwirkungen, dass die Plasma-Konzentrationen verringert werden müssen. Diese Zusammenhänge sind jedoch weniger gut untersucht und werden in dieser Dissertation nicht näher diskutiert. In diesem interdisziplinären Feld ist immer noch viel Forschung nötig um beispielsweise Unsicherheiten bei einzelnen Werten wie z.B. AUC/MIC zu minimieren. Diese beinhalten: Verbesserung der Genauigkeit und Präzision von bioanalytischen Methoden welche für die Bestimmung der Gesamtkonzentration und der freien Konzentration in biologischen Matrices verwendet werden um AUC und Cmax zu bestimmen. Diese Parameter werden in pharmakodynamischen Überlegungen in Beziehung zur MHK gesetzt. Da die MHK-Bestimmung oft erheblichen Schwankungen und auch Unterschieden zwischen verschiedenen mikrobiologischen Laboratorien unterliegt, kommt der Konzentrationsbestimmung der Antibiotika besondere Bedeutung zu, weil sie mit naturwissenschaftlich exakten Methoden möglich ist. Aus den Verteilungsvolumina von Antibiotika lassen sich schließlich auch noch Informationen über die intrazelluläre Konzentration und Wirksamkeit von Antibiotika ableiten. KW - Antimikrobieller Wirkstoff KW - Pharmakokinetik KW - Pharmakodynamik KW - LC-MS KW - LC-MS/MS KW - anti-infectives KW - Antiinfektiva KW - mass spectrometry KW - liquid chromatography KW - antibiotic KW - pharmacokinetic KW - clinical study Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-109215 ER - TY - THES A1 - ElBashir, Rasha T1 - Development of New Mass Spectrometry-based Methods for the Analysis of Posttranslational Modifications T1 - Entwicklung neuer massenspektrometrischer Methoden für die Analyse posttranslationaler Proteinmodifikationen N2 - Posttranslational modifications (PTMs) play a crucial role in many cellular processes. They are reversible, dynamic, and highly regulated events that alter the properties of proteins and increase their functional diversity. The identification and quantification of PTMs are critical for deciphering the molecular mechanisms of PTMs-related biological processes and disease treatment and prevention. Two of the most common and important PTMs that regulate many protein functions are acetylation and phosphorylation. An important role of acetylation is the regulation of DNA/RNA-protein interactions. A prominent example for this are histones, whose tail regions are lysine-rich and can be highly acetylated at their N-terminal domain. In spite of the utmost importance of this PTM, methods that allow the accurate measuring the site-specific acetylation degree are missing. One of the challenges in quantifying the acetylation degree at an individual lysine residue of the histones N-termini is the occurrence of multiple lysines in close proximity. Herein, we describe the development of the ”Fragment Ion Patchwork Quantification,” a new mass spectrometry-based approach for the highly accurate quantification of sites-pecific acetylation degrees. This method combines 13C1-acetyl derivatization on the protein level, proteolysis by low-specificity proteases and quantification on the fragment ion level. Acetylation degrees are determined from the isotope patterns of acetylated b and y ions. We have shown that this approach allows determining the site-specific acetylation degrees of all lysine residues for all core histones of Trypanosoma brucei. In addition, we demonstrate the use of this approach to identify the substrate sites of histone acetyltransferases and to monitor the changes in acetylation of the histones of canonical nucleosome and transcription start site nucleosomes. Phosphorylation is one of the most common and most important PTMs. The analysis of the human genome showed that there are about 518 kinases and more than 500,000 phosphorylation sites are believed to exist in the cellular proteome. Protein phosphorylation plays a crucial role in signaling many different cell processes, such as intercellular communication, cell growth, differentiation of proliferation and apoptosis. Whereas MS-based identification and relative quantification of singly phosphorylated peptides have been greatly improved during the last decade, and large-scale analysis of thousands of phosphopeptides can now be performed on a routine-base, the analysis of multi-phosphorylated peptides is still lagging vastly behind. The low pKa value of phosphate group and the associated negative charge are considered the major source of the problems with the analysis of multi-phosphorylated peptides. These problems include the formation of phosphopeptide-metal complexes during liquid chromatography (e.g. Fe 3+), which leads to a drastic deterioration of the chromatographic properties of these peptides (peak tailing), the decreased ionization efficiencies of phosphorylated peptides compared to their unphosphorylated counterparts, the labile nature of phosphate during CID/HCD fragmentation, and the unsuitability of low-charged phosphopeptides for ETD fragmentation are the most important factors that hinder phosphorylation analysis by LC-MS/MS. Here we aimed to develop a method for improving the identification of multi-phosphorylated peptides as well as the localization of phosphorylation sites by charge-reversal derivatization of the phosphate groups. This method employs a carbodiimide-mediated phosphoramidation to converted the phosphates to stable aromatic phosphoramidates. This chemical modification of phosphosite(s) reversed the negative charge of the phosphate group(s) and increased the number of the positive charges within the phosphopeptide. This modification prevented the formation of phosphopeptide-metal ion complexes that dramatically decreases or completely diminishes the signal intensity of protonated phosphopeptides, specifically multi-phosphorylated peptides. Furthermore, the increased net charge the (phospho-)peptides made them suitable for ETD fragmentation, which generated a high number of fragment ions with high intensities that led to a better phosphopeptide identification and localization of phosphosite(s) with high confidence. N2 - Posttranslationale Modifikationen (PTMs) spielen eine entscheidende Rolle in vielen zellulären Prozessen. Sie sind reversible, dynamische und hochregulierte Ereignisse, die die Proteineneigenschaften verändern und ihre funktionale Diversität erhöhen. Die Identifizierung und Quantifizierung von PTMs sind wesentlich für die Entschlüsselung der molekularen Mechanismen von PTM-regulierten biologischen Prozessen und für ein besseres Verständnis der Rolle posttranslationaler Modifikationen bei einer Vielzahl von Krankheiten. Zwei der bedeutendsten PTMs, welche die Funktion unzähliger Proteine regulieren sind die Acetylierung an Lysin-Resten und die Phosphorylierung an Serin-, Threonin- und Tyrosinresten. Im Rahmen dieser Arbeit wurden eine neue Methode zur Bestimmung des positionsspezifischen Acetylierungsgrades, sowie verbesserte Methoden für die Analyse der Phosphorylierung mittels Flüssigchromatographie-gekoppelter Tandem Massenspektrometrie entwickelt. Wir haben eine neue MS-basierte Methode (”Fragment Ion Patchwork Quantification”) entwickelt, welche es erlaubt die Acetylierungsgrade an individuellen Positionen mit hoher Genauigkeit zu messen. Diese Methode kombiniert die 13C1- Acetylderivatisierung von intakte Proteine, die Proteolyse durch Proteasen mit niedriger Spezifität, und die Quantifizierung auf dem MS2-Level. Die Acetylierungsgrade werden aus den Isotopenmustern von acetylierten b- und y-Ionen bestimmt. Obwohl unsere Methode zur Quantifizierung der positionsspezifischen Acetylierungsgrade auf jedes beliebige Protein angewandt werden kann, stand bei der Methodenentwicklung die Analyse der Histonacetylierung aufgrund ihrer herausragenden Bedeutung bei der Regulation der Genexpression im Vordergrund. Wir haben gezeigt, dass mit dieser Methode die Bestimmung der positionsspezifischen Acetylierungsgrade an allen Lysin Resten aller Core-Histone von Nukleosomhistone von Trypanosoma brucei möglich ist. Darüber hinaus haben wir diese Methode angewandt, um die Substrat-Positionen von Histon Acetyltransferasen zu identifizieren und um quantitative Veränderungen der Acetylierung an Histonen aus kanonischen Nukleosomen sowie Nukleosomen an Transkriptionsstartstellen zu analysieren. Phosphorylierung ist eine der häufigsten und wichtigsten posttranslational Proteinmodifikationen. Im Verlauf des Sequenzierung des humanen Genoms wurden 518 Gene für Proteinkinasen entdeckt und es wird angenommen, dass im zellulären Proteom mehr als 500 000 Phosphorylierungsstellen existieren. Die Proteinphosphorylierung spielet eine entscheidende Rolle in der Signalisierung vieler verschiedener Zellprozesse wie zum Beispiel der interzellulären Kommunikation, dem Zellwachstum, der Differenzierung der Proliferation und der Apoptose. Während bei der massenspektrometrie-basierte Identifizierung und relativen Quantifizierung von einfach phosphorylierten Peptiden in den letzten große Fortschritte erzielt wurden, und die Analyse tausender Phosphopeptide mittlerweile häufig routinemäßig durchgeführt werden kann, bereitet die massenspektrometrische Analyse merhfach phosphorylierter Peptide nach wie vor große Probleme. Der niedrige pKa-Wert der Phosphatgruppe, und die damit einhergehende negative Ladung ist die Hauptursache für die Probleme bei der Analyse merhfach phosphorylierter Peptide. Die mehrfache negative Ladung dieser Peptide führt zu einer ausgeprägten Neigung zur Komplexbildung mit mehrwertigen Metallionen (wie z.B. Fe3+), welche zu einer drmatischen Verschlechterung der chromatographischen Eigenschaften dieser Peptide führt (Peak Tailing), zu einer Verschlechterung der Ionisierungseffizienz, und zu einem ungewöhnlich niedrigen Protonierungsgrad im Positivionen-Modus, welcher diese Peptide für eine Fragmentierung mittels ETD ungeeignet macht. Im Rahmen dieser Arbeit wurde mittels chemischer Modifikation der Phosphatgruppe versucht sowohl die Detektion von mehrfach-phosphorylierten Peptiden, als auch die Lokalisierung von Phosphorylierungsstellen zu verbessern. Hierfür wurden die Phosphatgruppen unter Verwendung des Aktivierungsreagenzes EDC in hydrolysestabile, aromatische Phosphoramidate überführt. Die durch diese Modifikation erzielte Ladungsumkehr führt wie erwartet zu einer verbesserten Signalintensität bei den entsprechend modifizierten Phosphopeptiden, sowie zu einem verbesserten Fragmentierungsverhalten bei ETD, und somit letztlich zu einer verbesserten Lokalisierbarkeit der Phosphatgruppe inerhalb des Peptids. KW - LC-MS KW - Posttranslationale Änderung KW - Acetylierung KW - Phosphorylierung KW - Quantifizierung KW - Mass Spectrometry KW - PTMs KW - Acetylation KW - Quantitation KW - Phosphorylation Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-153731 ER - TY - THES A1 - Rodamer, Michael T1 - Development of practice-oriented LC-MS/MS methods for the determination of important drugs and their application for building PK/PD concepts T1 - Die Verwendung von praxisorientierten LC-MS/MS Methoden für die Bestimmung von wichtigen Arzneistoffen und ihre Verwendung zur Erstellung von PK/PD Konzepten N2 - In this thesis eight robust and reliable LC-MS/MS methods were developed and validated to analyze atorvastatin, clopidogrel, furosemide, itraconazole, loratadine, naproxen, nisoldipine and sunitinib in human plasma. The active metabolites 2-hydroxyatorvastatin, 4-hydroxyatorvastatin, hydroxyitraconazole, descarboethoxy-loratadine, 4-hydroxynisoldipine and N-desethylsunitinib were also included in the corresponding methods. Due to the different physical, chemical and pharmacokinetic properties of the analytes a wide spectrum regarding sample preparation techniques, chromatography and mass spectrometric detection was covered. Protein precipitation methods were developed for furosemide, itraconazole, naproxen, nisoldipine and sunitinib. Liquid-liquid extraction methods were developed for atorvastatin, clopidogrel and loratadine. Criteria to choose protein precipitation or liquid-liquid extraction were the final plasma concentrations of the drugs, which are mainly dependant on the dose, bioavailability and t1/2 and of course cost-effectiveness. Altogether, the methods have a concentration range from 0.001 ng/mL (LLOQ of clopidogrel) to 50000 ng/mL (highest calibration point for naproxen), covering 5 x 107 orders of magnitude. The runtime of the methods ranged from 2 to 4 minutes, facilitating a high sample throughput. All developed methods were validated according to recent guidelines as they were used to analyze sampes from clinical trials. Excellent linearity, intra-day and inter-day precision and accuracy were observed in the validated calibration ranges. Hemolyzed, lipemic and different batches of human plasma as well as sample dilution did not affect the determiantion of the analytes. Clopidogrel, loratadine, nisoldipine and sunitinib and if available their metabolites were subjected to a matrix effect test, resulting in no influence of different batches of human plasma on the analytical methods. Noteworthy is clopidogrel that shows a slight effect on one of the two used mass spectrometers. However, that effect was reproducible and did therefore not affect clopidogrel determination. No evidence of instability during chromatography, extraction and sample storage processes for all analytes except 4-hydroxyatorvastatin was found, for which a significant decrease was observed after three months. During incurred sample reanalysis of study samples 95 % of the samples were within ±15 % with respect to the first analysis. Moreover, the atorvastatin, loratadine and clopidogrel method were compared on two generations of triple quadrupole mass spectrometers, the API 3000™ and the API 5000™. The new ion source and the changes in the ion path of the API 5000™ provided higher sensitivity, the extend depending on the substance. However, the API 3000™ had very good precision in the performed system comparison. The validated methods showed excellent performance and quality data during routine sample analysis of eight clinical trials. Moreover, they are suitable for high sample throughput due to their short run times. N2 - In dieser Dissertation wurden acht robuste und verlässliche LC-MS/MS-Methoden zur Analyse von Atorvastatin, Clopidogrel, Furosemid, Itraconazol, Loratadin, Naproxen Nisoldipin und Sunitinib in Humanplasma entwickelt und validiert. Außerdem enthalten die Methoden die aktiven Metaboliten 2-Hydroxyatorvastatin, 4-Hydroxyatorvastatin, Hydroxyitraconazol, Descarboethoxyloratadin, 4-Hydroxynisoldipin und N-Desethylsunitinib. Wegen der unterschiedlichen physikalischen, chemischen und pharmakokinetischen Eigenschaften der Analyten, deckt diese Arbeit ein weites Spektrum bezüglich Probenaufarbeitung, Chromatographie und Massenspektrometrie ab. Präzipitationsmethoden wurden für Furosemid, Itraconazol, Naproxen, Nisoldipin und Sunitinib entwickelt. Flüssig-flüssig-Extraktionen wurden für Atorvastatin, Clopidogrel und Loratadin entwickelt. Kriterien für die Auswahl von Präzipitation oder Extraktion waren die erwartete Plasmakonzentration, die im Wesentlichen von der Dosis, Bioverfügbarkeit und Halbwertszeit abhängig ist, und natürlich Kosteneffektivität. Insgesamt erstrecken sich die Methoden über einen Kalibrierbereich von 0.001 ng/mL (LLOQ von Clopidogrel) bis zu 50000 ng/mL (HLOQ von Naproxen), das entspricht 5x107 Größenordnungen. Die Laufzeiten pro Probe liegen im Bereich von zwei bis vier Minuten, was einen sehr hohen Probendurchsatz ermöglicht. Alle in dieser Arbeit entwickelten Methoden wurden gemäß aktueller Richtlinien (FDA, GLP) validiert und verwendet um Proben aus Pharmakokinetikstudien zu analysieren. Ausgezeichnete Linearität, Präzision und Genauigkeit zeichnen diese Methoden aus. Hämolysiertes, lipämisches und verschiedene Batches von Humanplasma, sowie Vorverdünnung hatten bei keiner Methode Einfluss auf die Bestimmung der Analyten. Clopidogrel, Loratadin, Nisoldipin und Sunitinib und gegebenenfalls deren Metabolite wurden einem Matrix-Effekt-Test unterzogen. Dabei wurde festgestellt, dass keine der Methoden durch die Probenmatrix beeinflusst wurde. Erwähnenswert ist Clopidogrel, da an einem der Massenspektrometer ein leichter Effekt beobachtet werden konnte, der sich auf alle untersuchten Matrices gleich auswirkte und somit keinen Einfluss auf die gesamte Methode hatte. Weiterhin fand sich bei keiner der untersuchten Substanzen ein Hinweis auf Instabilität während der Probenlagerung, -aufarbeitung und -messung, außer bei 4-Hydroxyatorvastatin, dessen Konzentration nach drei Monaten signifikant abnahm. Während der Reanalyse von Studienproben (incurred samples) lagen über 95 % der Proben innerhalb von ±15 % im Vergleich zur ersten Messung. Außerdem wurden die Methoden zur Bestimmung von Atorvastatin, Loratadin und Clopidogrel an zwei Generationen von Massenspektrometern verglichen, nämlich dem API 3000™ und dem API 5000™. Die neue Ionenquelle und die Verbesserungen im Ionenpfad beim API 5000™ ermöglichten - abhängig von der analysierten Substanz - höhere Sensitivität. Allerdings konnte das API 3000™ bei den durchgeführten Experimenten mit einer hohen Präzision aufwarten. Die validierten Methoden zeigten im Alltagbetrieb bei der Messung von acht klinischen Studien hervorragende Performance und Qualitätsdaten. Darüber hinaus sind die Methoden aufgrund ihrer kurzen Laufzeiten ideal für Messungen die einen hohen Probendurchsatz erfordern. KW - LC-MS KW - Validierung KW - Tandem-Massenspektrometrie KW - Bioanalytik KW - Klinische Studie KW - LC-MS/MS KW - Tandem Mass Spectrometry KW - Method Validation KW - Pharmacokinetics Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-70809 ER - TY - THES A1 - Brink, Andreas T1 - The biological significance of chemically-induced DNA adducts in relation to background DNA damage T1 - Die biologische Bedeutung von chemisch induzierten DNA-Addukten in Relation zum Hintergrund-DNA-Schaden N2 - No abstract available KW - DNS-Schädigung KW - DNS-Strangbruch KW - HPLC-MS KW - API-Massenspektrometrie KW - LC-MS KW - Gentoxikologie KW - Mutagenitätstest KW - Dosis-Wirkungs-Beziehung KW - DNA-Addukte KW - Dosis-Wirkungs-Beziehung KW - Hintergrund-DNA-Schaden KW - Comet assay KW - DNA adducts KW - Dose response relationships KW - Background DNA damage Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-23850 ER -