TY - JOUR A1 - Bernuth, Silvia A1 - Vater, Adrian A1 - Fuchs, Konrad F. A1 - Meffert, Rainer H. A1 - Jakubietz, Rafael G. T1 - Perfusion changes in perforator-based propeller flaps JF - Journal of Reconstructive Microsurgery Open N2 - Background  To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible. Methods  A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected. Results  Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day. Conclusion  Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow. KW - propeller flap KW - perfusion KW - lower extremity Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-350491 SN - 2377-0813 VL - 8 IS - 1 ER - TY - JOUR A1 - Kerwagen, Fabian A1 - Fuchs, Konrad F. A1 - Ullrich, Melanie A1 - Schulze, Andres A1 - Straka, Samantha A1 - Krop, Philipp A1 - Latoschik, Marc E. A1 - Gilbert, Fabian A1 - Kunz, Andreas A1 - Fette, Georg A1 - Störk, Stefan A1 - Ertl, Maximilian T1 - Usability of a mHealth solution using speech recognition for point-of-care diagnostic management JF - Journal of Medical Systems N2 - The administrative burden for physicians in the hospital can affect the quality of patient care. The Service Center Medical Informatics (SMI) of the University Hospital Würzburg developed and implemented the smartphone-based mobile application (MA) ukw.mobile1 that uses speech recognition for the point-of-care ordering of radiological examinations. The aim of this study was to examine the usability of the MA workflow for the point-of-care ordering of radiological examinations. All physicians at the Department of Trauma and Plastic Surgery at the University Hospital Würzburg, Germany, were asked to participate in a survey including the short version of the User Experience Questionnaire (UEQ-S) and the Unified Theory of Acceptance and Use of Technology (UTAUT). For the analysis of the different domains of user experience (overall attractiveness, pragmatic quality and hedonic quality), we used a two-sided dependent sample t-test. For the determinants of the acceptance model, we employed regression analysis. Twenty-one of 30 physicians (mean age 34 ± 8 years, 62% male) completed the questionnaire. Compared to the conventional desktop application (DA) workflow, the new MA workflow showed superior overall attractiveness (mean difference 2.15 ± 1.33), pragmatic quality (mean difference 1.90 ± 1.16), and hedonic quality (mean difference 2.41 ± 1.62; all p < .001). The user acceptance measured by the UTAUT (mean 4.49 ± 0.41; min. 1, max. 5) was also high. Performance expectancy (beta = 0.57, p = .02) and effort expectancy (beta = 0.36, p = .04) were identified as predictors of acceptance, the full predictive model explained 65.4% of its variance. Point-of-care mHealth solutions using innovative technology such as speech-recognition seem to address the users’ needs and to offer higher usability in comparison to conventional technology. Implementation of user-centered mHealth innovations might therefore help to facilitate physicians’ daily work. KW - mHealth KW - digital Health KW - speech recognition KW - usability KW - user-centered design KW - clinical systems Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324002 VL - 47 IS - 1 ER - TY - JOUR A1 - Fuchs, Konrad F. A1 - Heilig, Philipp A1 - McDonogh, Miriam A1 - Boelch, Sebastian A1 - Gbureck, Uwe A1 - Meffert, Rainer H. A1 - Hoelscher-Doht, Stefanie A1 - Jordan, Martin C. T1 - Cement-augmented screw fixation for calcaneal fracture treatment: a biomechanical study comparing two injectable bone substitutes JF - Journal of Orthopaedic Surgery and Research N2 - Background The role of cement-augmented screw fixation for calcaneal fracture treatment remains unclear. Therefore, this study was performed to biomechanically analyze screw osteosynthesis by reinforcement with either a calcium phosphate (CP)-based or polymethylmethacrylate (PMMA)-based injectable bone cement. Methods A calcaneal fracture (Sanders type IIA) including a central cancellous bone defect was generated in 27 synthetic bones, and the specimens were assigned to 3 groups. The first group was fixed with four screws (3.5 mm and 6.5 mm), the second group with screws and CP-based cement (Graftys (R) QuickSet; Graftys, Aix-en-Provence, France), and the third group with screws and PMMA-based cement (Traumacem (TM) V+; DePuy Synthes, Warsaw, IN, USA). Biomechanical testing was conducted to analyze peak-to-peak displacement, total displacement, and stiffness in following a standardized protocol. Results The peak-to-peak displacement under a 200-N load was not significantly different among the groups; however, peak-to-peak displacement under a 600- and 1000-N load as well as total displacement exhibited better stability in PMMA-augmented screw osteosynthesis compared to screw fixation without augmentation. The stiffness of the construct was increased by both CP- and PMMA-based cements. Conclusion Addition of an injectable bone cement to screw osteosynthesis is able to increase fixation strength in a biomechanical calcaneal fracture model with synthetic bones. In such cases, PMMA-based cements are more effective than CP-based cements because of their inherently higher compressive strength. However, whether this high strength is required in the clinical setting for early weight-bearing remains controversial, and the non-degradable properties of PMMA might cause difficulties during subsequent interventions in younger patients. KW - arthritis KW - bone KW - calcaneus KW - cement KW - fracture KW - fixation KW - osteoporosis KW - sanders KW - screw Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230336 VL - 15 ER -