TY - JOUR A1 - Achenbach, Leonard A1 - Huppertz, Gunnar A1 - Zeman, Florian A1 - Weber, Johannes A1 - Luig, Patrick A1 - Rudert, Maximilian A1 - Krutsch, Werner T1 - Multicomponent stretching and rubber band strengthening exercises do not reduce overuse shoulder injuries: a cluster randomised controlled trial with 579 handball athletes JF - BMJ Open Sport & Exercise Medicine N2 - Objectives Handball is associated with a high risk of overuse shoulder injury. This study investigated if an injury prevention programme effectively reduces overuse injury to the throwing shoulder of handball athletes. Methods 61 men’s and women’s handball teams (u-19 and senior athletes) were cluster-randomised into an intervention and a control group in the 2019–2020 season. Players of the intervention group regularly carried out an injury prevention programme. Both groups documented overuse shoulder injuries via an online questionnaire every second week. The primary endpoint was the prevalence of overuse injury to the throwing shoulder. Secondary endpoints were the influence of compliance on the primary endpoint and intensity of overuse shoulder symptoms measured by a shortened, handball-specific Western Ontario Shoulder Index (WOSI). Results 31 teams (295 players) in the intervention group and 30 teams (284 players) in the control group were included for analyses. The overall questionnaire response rate was 61%. The average prevalence of overuse shoulder injury did not significantly differ between the intervention group (n=109, 38.4% (95% CI 32.9% to 44.2%)) and the control group (n=106, 35.9% (95% CI 30.7% to 41.6%), p=0.542). Compliance with the intervention programme did not significantly affect overuse shoulder injury (p=0.893). Using generalised estimating equations for WOSI, the estimated mean for the intervention group was 44.6 points (95% CI 42.0 to 47.1) and 47.6 points for the control group (95% CI 44.9 to 50.3, p=0.111). Conclusions A multicomponent exercise programme using rubber bands and stretching did not significantly reduce the prevalence or symptoms of overuse throwing shoulder injury in handball athletes of both sexes. Randomised controlled study; level of evidence I. KW - handball KW - multicomponent stretching KW - shoulder injuries Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300770 SN - 2055-7647 VL - 8 IS - 1 ER - TY - JOUR A1 - Altmann, Stephan A1 - Mut, Jürgen A1 - Wolf, Natalia A1 - Meißner-Weigl, Jutta A1 - Rudert, Maximilian A1 - Jakob, Franz A1 - Gutmann, Marcus A1 - Lühmann, Tessa A1 - Seibel, Jürgen A1 - Ebert, Regina T1 - Metabolic glycoengineering in hMSC-TERT as a model for skeletal precursors by using modified azide/alkyne monosaccharides JF - International Journal of Molecular Sciences N2 - Metabolic glycoengineering enables a directed modification of cell surfaces by introducing target molecules to surface proteins displaying new features. Biochemical pathways involving glycans differ in dependence on the cell type; therefore, this technique should be tailored for the best results. We characterized metabolic glycoengineering in telomerase-immortalized human mesenchymal stromal cells (hMSC-TERT) as a model for primary hMSC, to investigate its applicability in TERT-modified cell lines. The metabolic incorporation of N-azidoacetylmannosamine (Ac\(_4\)ManNAz) and N-alkyneacetylmannosamine (Ac\(_4\)ManNAl) into the glycocalyx as a first step in the glycoengineering process revealed no adverse effects on cell viability or gene expression, and the in vitro multipotency (osteogenic and adipogenic differentiation potential) was maintained under these adapted culture conditions. In the second step, glycoengineered cells were modified with fluorescent dyes using Cu-mediated click chemistry. In these analyses, the two mannose derivatives showed superior incorporation efficiencies compared to glucose and galactose isomers. In time-dependent experiments, the incorporation of Ac\(_4\)ManNAz was detectable for up to six days while Ac\(_4\)ManNAl-derived metabolites were absent after two days. Taken together, these findings demonstrate the successful metabolic glycoengineering of immortalized hMSC resulting in transient cell surface modifications, and thus present a useful model to address different scientific questions regarding glycosylation processes in skeletal precursors. KW - hMSC-TERT KW - metabolic glycoengineering KW - glycocalyx KW - modified monosaccharides KW - click chemistry Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-259247 SN - 1422-0067 VL - 22 IS - 6 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Gilbert, Fabian A1 - Blank, Marc A1 - Papazoglou, Jannis A1 - Rudert, Maximilian A1 - Nöth, Ulrich A1 - Steinert, Andre F. T1 - The Mayo conservative hip: complication analysis and management of the first 41 cases performed at a University level 1 department JF - BMC Muskoskeletal Disorders N2 - Background: To prevent bone loss in hip arthroplasty, several short stem systems have been developed, including the Mayo conservative hip system. While there is a plethora of data confirming inherent advantages of these systems, only little is known about potential complications, especially when surgeons start to use these systems. Methods: In this study, we present a retrospective analysis of the patients’ outcome, complications and the complication management of the first 41 Mayo conservative hips performed in 37 patients. For this reason, functional scores, radiographic analyses, peri- and postoperative complications were assessed at an average follow-up of 35 months. Results: The overall HHS improved from 61.2 pre-operatively to 85.6 post-operatively. The German Extra Short Musculoskeletal Function Assessment Questionnaire (XSFMA-D) improved from 30.3 pre-operatively to 12.2 post-operatively. The most common complication was an intraoperative non-displaced fracture of the proximal femur observed in 5 cases (12.1%). Diabetes, higher BMI and older ages were shown to be risk factors for these intra-operative periprosthetic fractures (p < 0.01). Radiographic analysis revealed a good offset reconstruction in all cases. Conclusion: In our series, a high complication rate with 12.1% of non-displaced proximal femoral fractures was observed using the Mayo conservative hip. This may be attributed to the flat learning curve of the system or the inherent patient characteristics of the presented cohort." KW - total hip arthroplasty KW - short hip stem KW - mayo stem KW - minimal invasive surgery Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-157812 VL - 18 IS - 250 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Holzapfel, Boris Michael A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre Friedrich T1 - Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants JF - Archives of Medical Science N2 - Introduction The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. Material and methods In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. Results On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). Conclusions Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease. KW - implant fit KW - bi-compartmental knee arthoplasty KW - bi-compartmental KW - implant positioning KW - knee osteoarthritis KW - knee arthroplasty KW - patient-specific KW - knee alignment Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159668 VL - 14 IS - 6 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Horas, Konstantin A1 - Holzapfel, Boris M. A1 - Gilbert, Fabian A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre F. T1 - Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty JF - BMC Musculoskeletal Disorders N2 - Background For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA). Methods We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses. Results On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching. Conclusion The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system. KW - total knee replacement KW - knee axis KW - patient-specific knee arthroplasty KW - knee osteoarthritis KW - implant positioning Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230012 VL - 21 ER - TY - JOUR A1 - Boelch, Sebastian P. A1 - Gurok, Anna A1 - Gilbert, Fabian A1 - Weißenberger, Manuel A1 - Rudert, Maximilian A1 - Barthel, Thomas A1 - Reppenhagen, Stephan T1 - Why compromise the patella? Five-year follow-up results of medial patellofemoral ligament reconstruction with soft tissue patellar fixation JF - International Orthopaedics N2 - Purpose This study investigates the redislocation rate and functional outcome at a minimum follow-up of five years after medial patellofemoral ligament (MPFL) reconstruction with soft tissue patellar fixation for patella instability. Methods Patients were retrospectively identified and knees were evaluated for trochlea dysplasia according to Dejour, for presence of patella alta and for presence of cartilage lesion at surgery. At a minimum follow-up of five years, information about an incident of redislocation was obtained. Kujala, Lysholm, and Tegner questionnaires as well as range of motion were used to measure functional outcome. Results Eighty-nine knees were included. Follow-up rate for redislocation was 79.8% and for functional outcome 58.4%. After a mean follow-up of 5.8 years, the redislocation rate was 5.6%. There was significant improvement of the Kujala score (68.8 to 88.2, p = 0.000) and of the Lysholm score (71.3 to 88.4, p = 0.000). Range of motion at follow-up was 149.0° (115–165). 77.5% of the knees had patella alta and 52.9% trochlear dysplasia types B, C, or D. Patellar cartilage legions were present in 54.2%. Redislocations occurred in knees with trochlear dysplasia type C in combination with patella alta. Conclusion MPFL reconstruction with soft tissue patellar fixation leads to significant improvement of knee function and low midterm redislocation rate. Patients with high-grade trochlear dysplasia should be considered for additional osseous correction. KW - MPFL KW - medial patellofemoral ligament KW - patella instability KW - patella dislocation KW - trochlear dysplasia KW - patella alta Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235751 SN - 0341-2695 VL - 45 ER - TY - JOUR A1 - Boelch, Sebastian P. A1 - Roth, Magnus A1 - Arnholdt, Joerg A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Synovial fluid aspiration should not be routinely performed during the two-stage exchange of the knee JF - BioMed Research International N2 - Purpose. Detection of infection persistence during the two-stage exchange of the knee for periprosthetic joint infection is challenging. Synovial fluid culture (SFC) and synovial white blood cell count (SWBCC) before joint reimplantation are widespread diagnostic means for this indication. The sensitivity and specificity of SFC and of SWBCC for infection persistence before planned reimplantation were evaluated. Methods. 94 two-stage exchanges of the knee with synovial fluid aspiration performed after a drug holiday of at least 14 days and before reimplantation or spacer exchange (planned reimplantation) were retrospectively analyzed. Only cases with at least 3 intraoperative samples at planned reimplantation were included. SFC and SWBCC were compared to pathogen detection (SFC\(_{(culture)}\)/SWBCC\(_{(culture)}\) and to histopathological signs of infection persistence (SFC\(_{(histo)}\)/SWBCC\(_{(histo)}\) from intraoperative samples at planned reimplantation. For SFC, the sensitivity and specificity were calculated. For SWBCC, the optimal cut-off value with its sensitivity and specificity was calculated with the Youden-Index. Results. Sensitivity and specificity of SFC\(_{(culture)}\) were 0.0% and 98.9%. Sensitivity and specificity of SFC\(_{(histo)}\) were 3.4% and 100%. The optimal cut-off value for SWBCC\(_{(culture)}\) was 4450 cells/μl with a sensitivity of 50.0% and a specificity of 86.5%. The optimal cut-off value for SWBCC\(_{(histo)}\) was 3250 cells/μl with a sensitivity of 35.7% and a specificity of 92.9%. Conclusion. The detection of infection persistence remains challenging and a consented approach is lacking. The results do not warrant the routine performance of SFC during the two-stage exchange at the knee. SWBCC can be used to confirm infection persistence at high cut-offs, but they only occur in few patients and are therefore inappropriate for the routine use. KW - knee KW - two-stage exchange KW - Synovial Fluid Aspiration Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176800 VL - 2018 IS - 6720712 ER - TY - JOUR A1 - Boelch, Sebastian P. A1 - Rueckl, Kilian A1 - Fuchs, Clara A1 - Jordan, Martin A1 - Knauer, Markus A1 - Steinert, Andre A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Comparison of elution characteristics and compressive strength of biantibiotic-loaded PMMA bone cement for spacers: Copal\(^®\) spacem with gentamicin and vancomycin versus Palacos\(^®\) R+G with vancomycin JF - BioMed Research International N2 - Purpose. Copal\(^®\) spacem is a new PMMA bone cement for fabricating spacers. This study compares elution of gentamicin, elution of vancomycin, and compressive strength of Copal\(^®\) spacem and of Palacos\(^®\) R+G at different vancomycin loadings in the powder of the cements. We hypothesized that antibiotic elution of Copal\(^®\) spacem is superior at comparable compressive strength. Methods. Compression test specimens were fabricated using Copal\(^®\) spacem manually loaded with 0.5 g gentamicin and additionally 2 g, 4 g, and 6 g of vancomycin per 40 g of cement powder (COP specimens) and using 0.5 g gentamicin premixed Palacos\(^®\) R+G manually loaded with 2 g, 4 g, and 6 g of vancomycin per 40 g of cement powder (PAL specimens). These specimens were used for determination of gentamicin and vancomycin elution (in fetal calf serum, at 22°C) and for determination of compressive strength both prior and following the elution tests. Results. Cumulative gentamicin concentrations (p < 0.005) and gentamicin concentration after 28 days (p ≤ 0.043) were significantly lower for COP specimens compared to PAL specimens. Cumulative vancomycin concentrations were significantly higher (p ≤ 0.043) for COP specimens after the second day. Vancomycin concentrations after 28 days were not significantly higher for the Copal specimens loaded with 2 g and 4 g of vancomycin. Compressive strength was not significantly different between COP specimens and PAL specimens before elution tests. Compressive strength after the elution tests was significantly lower (p = 0.005) for COP specimens loaded with 2 g of vancomycin. Conclusion. We could not demonstrate consistent superior antibiotic elution from Copal\(^®\) spacem compared to Palacos\(^®\) R+G for fabricating gentamicin and vancomycin loaded spacers. The results do not favor Copal\(^®\) spacem over Palacos\(^®\) R+G for the use as a gentamicin and vancomycin biantibiotic-loaded spacer. KW - Copal\(^®\) spacem KW - PMMA bone cement KW - elution KW - compressive strength Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177435 VL - 2018 IS - 4323518 ER - TY - JOUR A1 - Boelch, Sebastian Philipp A1 - Barthel, Thomas A1 - Goebel, Sascha A1 - Rudert, Maximilian A1 - Plumhoff, Piet T1 - Calcinosis universalis - a rare case with classical presentation JF - Case Reports in Orthopedics N2 - Juvenile Dermatomyositis (JDM) is a rare autoimmune disease in children and adolescents. In these patients calcinosis might be the most characteristic symptom. However there are only few reported cases of intramuscular calcinosis in Dermatomyositis. We report a case of calcinosis universalis (CU) of the elbow in JDM successfully treated with broaching. The patient, a 24-year-old woman, suffered from a long history of JDM. On examination she presented with a fistula lateral to the olecranon and pain of the right elbow joint. Plain X-rays displayed a diffuse pattern of multiple periarticular, subcutaneous, and intramuscular calcifications. The patient underwent surgery for histological and microbiological sampling as well as broaching. Intraoperatively sinus formation and subfascial hard calcium deposition were found. Due to the risk of collateral tissue damage, incomplete broaching was performed. A local infection with Staphylococcus was diagnosed and treated with antibiotics. On six-week and 30-month follow-up the patient was free of pain and had very good function. Calcifications on standard radiographs had almost resolved entirely. This case report gives a summary on calcinosis in Dermatomyositis and adds a new case of recalcitrant CU to the literature. Broaching surgery proved to be a reliable treatment option in symptomatic calcinosis. Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126300 VL - 2015 ER - TY - JOUR A1 - Boelch, Sebastian Philipp A1 - Rüeckl, Kilian A1 - Streck, Laura Elisa A1 - Szewczykowski, Viktoria A1 - Weißenberger, Manuel A1 - Jakuscheit, Axel A1 - Rudert, Maximilian T1 - Diagnosis of chronic infection at total hip arthroplasty revision is a question of definition JF - Biomed Research International N2 - Purpose. Contradicting definitions of periprosthetic joint infection (PJI) are in use. Joint aspiration is performed before total hip arthroplasty (THA) revision. This study investigated the influence of PJI definition on PJI prevalence at THA revision. Test quality of prerevision aspiration was evaluated for the different PJI definitions. Methods. 256 THA revisions were retrospectively classified to be infected or not infected. Classification was performed according to the 4 different definitions proposed by the Musculoskeletal Infection Society (MSIS), the Infectious Diseases Society of America (IDSA), the International Consensus Meeting (ICM), and the European Bone and Joint Infection Society (EBJIS). Only chronic PJIs were included. Results. PJI prevalence at revision significantly correlated with the applied PJI definition (p=0.01, Cramer's V=0.093). PJI prevalence was 20.7% for the MSIS, 25.4% for the ICM, 28.1% for the IDSA, and 32.0% for the EBJIS definition. For synovial fluid white blood cell count, the best ROC-AUC for predicting PJI was 0.953 in combination with the MSIS definition. Conclusion. PJI definition significantly influences the rate of diagnosed PJIs at THA revision. Synovial fluid white blood cell count is a reliable means to rule out PJI. In cases with a borderline high synovial white blood cell count before THA revision as the only sign of chronic PJI, an extended diagnostic work-up should be considered. KW - periprosthetic joint infection KW - algorithm KW - consensus Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-265762 VL - 2021 ER - TY - JOUR A1 - Boelch, Sebastian Philipp A1 - Weissenberger, Manuel A1 - Spohn, Frederik A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers JF - Journal of Orthopedic Surgery and Research N2 - Background: Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Methods: Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. Results: The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Conclusions: Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip. KW - two-stage exchange KW - hip KW - periprosthetic infection KW - joint aspiration KW - spacer Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-175576 VL - 13 IS - 7 ER - TY - JOUR A1 - Ebert, Regina A1 - Weissenberger, Manuel A1 - Braun, Clemens A1 - Wagenbrenner, Mike A1 - Herrmann, Marietta A1 - Müller‐Deubert, Sigrid A1 - Krug, Melanie A1 - Jakob, Franz A1 - Rudert, Maximilian T1 - Impaired regenerative capacity and senescence‐associated secretory phenotype in mesenchymal stromal cells from samples of patients with aseptic joint arthroplasty loosening JF - Journal of Orthopaedic Research N2 - Aseptic loosening of total hip and knee joint replacements is the most common indication for revision surgery after primary hip and knee arthroplasty. Research suggests that exposure and uptake of wear by mesenchymal stromal cells (MSC) and macrophages results in the secretion of proinflammatory cytokines and local osteolysis, but also impaired cell viability and regenerative capacity of MSC. Therefore, this in vitro study compared the regenerative and differentiation capacity of MSC derived from patients undergoing primary total hip arthroplasty (MSCprim) to MSC derived from patients undergoing revision surgery after aseptic loosening of total hip and knee joint implants (MSCrev). Regenerative capacity was examined by measuring the cumulative population doubling (CPD) in addition to the number of passages until cells stopped proliferating. Osteogenesis and adipogenesis in monolayer cultures were assessed using histological stainings. Furthermore, RT‐PCR was performed to evaluate the relative expression of osteogenic and adipogenic marker genes as well as the expression of markers for a senescence‐associated secretory phenotype (SASP). MSCrev possessed a limited regenerative capacity in comparison to MSCprim. Interestingly, MSCrev also showed an impaired osteogenic and adipogenic differentiation capacity compared to MSCprim and displayed a SASP early after isolation. Whether this is the cause or the consequence of the aseptic loosening of total joint implants remains unclear. Future research should focus on the identification of specific cell markers on MSCprim, which may influence complication rates such as aseptic loosening of total joint arthroplasty to further individualize and optimize total joint arthroplasty. KW - aseptic loosening KW - mesenchymal stromal cells KW - regenerative capacity KW - senescence‐associated secretory phenotype Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-238963 VL - 40 IS - 2 SP - 513 EP - 523 ER - TY - JOUR A1 - Eidmann, Annette A1 - Eisert, Marius A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Influence of Vitamin D and C on bone marrow edema syndrome — A scoping review of the literature JF - Journal of Clinical Medicine N2 - Bone marrow edema syndrome (BMES) is a rare disease with a largely unknown etiology. The aim of this scoping review is to systematically evaluate and combine the available evidence about vitamin D and C and BMES. The analysis of the manuscripts was based on country of origin, number of patients, gender, study type, epidemiology, localization, bone mineral density measurements, vitamin status and therapy. Sixty studies were included. The overall number of patients was 823 with a male-to-female ratio of 1.55:1 and a mean age of 40.9 years. Studies were very heterogeneous and of diverging scientific scope with a weak level of evidence. The hip was the most affected joint, followed by the foot and ankle and the knee; 18.3% of patients suffered from multifocal BMES. Sixteen studies reported on vitamin D levels, resulting in a high prevalence of vitamin D deficiency (47%) and insufficiency (17.9%) among BMES patients. Three BME manuscripts were associated with vitamin C deficiency. Current therapeutic interventions include conservative measures (mainly unloading), various osteoactive drugs and iloprost. In summary, data about BMES in association with vitamin status is limited. A causal relationship between vitamin D or vitamin C status, osteopenia, and BMES cannot be determined from the existing literature. KW - lower extremity KW - regional transient osteoporosis KW - bone marrow edema KW - vitamin D KW - vitamin C KW - scoping review Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-297356 SN - 2077-0383 VL - 11 IS - 22 ER - TY - JOUR A1 - Eidmann, Annette A1 - Ewald, Andrea A1 - Boelch, Sebastian P. A1 - Rudert, Maximilian A1 - Holzapfel, Boris M. A1 - Stratos, Ioannis T1 - In vitro evaluation of antibacterial efficacy of vancomycin-loaded suture tapes and cerclage wires JF - Journal of Materials Science: Materials in Medicine N2 - Usage of implants containing antibiotic agents has been a common strategy to prevent implant related infections in orthopedic surgery. Unfortunately, most implants with microbial repellent properties are characterized by accessibility limitations during daily clinical practice. Aim of this in vitro study was to investigate whether suture tapes and cerclage wires, which were treated with vancomycin, show a sustainable antibacterial activity. For this purpose, we used 24 stainless steel wire cerclages and 24 ultra-high molecular weight polyethylene and polyester suture tape test bodies. The test bodies were incubated for 30 min. in 100 mg/ml vancomycin solution or equivalent volumes of 0.9% NaCl. After measuring the initial solution uptake of the test bodies, antibacterial efficacy via agar diffusion test with Staphylococcus aureus and vancomycin elution tests were performed 1, 2, 3, and 6 days after incubation. Vancomycin-loaded tapes as well as vancomycin-loaded cerclage wires demonstrated increased bacterial growth inhibition when compared to NaCl-treated controls. Vancomycin-loaded tapes showed an additional twofold and eightfold increase of bacterial growth inhibition compared to vancomycin-loaded wires at day 1 and 2, respectively. Elution tests at day 1 revealed high levels of vancomycin concentration in vancomycin loaded tapes and wires. Additionally, the concentration in vancomycin loaded tapes was 14-fold higher when compared to vancomycin loaded wires. Incubating suture tapes and cerclage wires in vancomycin solution showed a good short-term antibacterial activity compared to controls. Considering the ease of vancomycin application on suture tapes or wires, our method could represent an attractive therapeutic strategy in biofilm prevention in orthopedic surgery. KW - anti-bacterial agents / administration & dosage KW - anti-bacterial agents / chemistry KW - bone wires KW - drug liberation KW - materials testing KW - anti-bacterial agents / pharmacology KW - biocompatible Materials KW - prostheses and implants KW - Staphylococcus aureus / drug effects KW - sutures KW - Vancomycin / administration & dosage KW - Vancomycin / chemistry KW - Vancomycin / pharmacology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260089 VL - 32 IS - 4 ER - TY - JOUR A1 - Eidmann, Annette A1 - Heinz, Tizian A1 - Oberfeld, Jan A1 - Weißenberger, Manuel A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Epidemiology and trends in cartilage surgery of the foot and ankle in Germany: an analysis of national healthcare billing and reporting data from 2006 to 2020 JF - Medicina N2 - Background and objectives: Cartilage surgery constitutes a standard intervention in foot and ankle procedures. Currently, there is a lack of epidemiological data on its frequency, age distribution, and surgical options for cartilage surgery. This study aimed to investigate the current landscape of cartilage surgery in Germany and identify the most common procedures from an epidemiological standpoint. Materials and methods: Medical billing and reporting data from the Federal Statistical Office of Germany, encompassing the period 2006–2020, was examined, including all foot and ankle cartilage surgical procedures (summarized under OPS codes 5-812 and 5-801). The dataset incorporated information on the affected joint, patient age and sex, and surgery type. Each surgical procedure was categorized as “debridement”, “regeneration” or “refixation”. Linear and nonlinear regression analyses were employed, with a statistical significance threshold of 0.05. Results: From the total of 136,501 procedures conducted during the study period, the most frequently performed interventions were microfracture (58,252) and chondroplasty (56,135), and thus, debridement procedures were in the leading position. The use of acellular membranes was the most used regenerative technique (n = 11,414). At the ankle joint, interventions were mostly arthroscopic and in men, while foot cartilage surgeries were preferably performed via open surgery and mostly in women. Age distribution analysis revealed two primary peaks: the first in the 20–25-year-old group (ankle and foot) and the second in the 45–50-year-old group (ankle) and 55–60-year-old group (foot). Refixation and regenerative procedures were more frequent among younger individuals, while debriding procedures were more frequent among older individuals. Regenerative procedures, particularly in the ankle, significantly increased over time. Conclusions: Cartilage surgery of the foot and ankle was common, with two primary age groups predominantly affected. Notably, recent years have witnessed a considerable rise in cartilage regenerative procedures. KW - cartilage surgery KW - foot and ankle procedures KW - epidemiological analysis KW - regenerative therapies KW - age distribution Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-362835 SN - 1648-9144 VL - 59 IS - 7 ER - TY - JOUR A1 - Eidmann, Annette A1 - Kamawal, Yama A1 - Luedemann, Martin A1 - Raab, Peter A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Demographics and etiology for lower extremity amputations — experiences of an university orthopaedic center in Germany JF - Medicina N2 - Background and Objectives: Currently, the worldwide incidence of major amputations in the general population is decreasing whereas the incidence of minor amputations is increasing. The purpose of our study was to analyze whether this trend is reflected among orthopaedic patients treated with lower extremity amputation in our orthopaedic university institution. Materials and Methods: We conducted a single-center retrospective study and included patients referred to our orthopaedic department for lower extremity amputation (LEA) between January 2007 and December 2019. Acquired data were the year of amputation, age, sex, level of amputation and cause of amputation. T test and Chi² test were performed to compare age and amputation rates between males and females; significance was defined as p < 0.05. Linear regression and multivariate logistic regression models were used to test time trends and to calculate probabilities for LEA. Results: A total of 114 amputations of the lower extremity were performed, of which 60.5% were major amputations. The number of major amputations increased over time with a rate of 0.6 amputation/year. Men were significantly more often affected by LEA than women. Age of LEA for men was significantly below the age of LEA for women (men: 54.8 ± 2.8 years, women: 64.9 ± 3.2 years, p = 0.021). Main causes leading to LEA were tumors (28.9%) and implant-associated complications (25.4%). Implant-associated complications and age raised the probability for major amputation, whereas malformation, angiopathies and infections were more likely to cause a minor amputation. Conclusions: Among patients in our orthopaedic institution, etiology of amputations of the lower extremity is multifactorial and differs from other surgical specialties. The number of major amputations has increased continuously over the past years. Age and sex, as well as diagnosis, influence the type and level of amputation. KW - lower extremity amputation KW - major amputation KW - minor amputation KW - orthopaedic surgery Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-304856 SN - 1648-9144 VL - 59 IS - 2 ER - TY - JOUR A1 - Heinz, Tizian A1 - Eidmann, Annette A1 - Anderson, Philip A1 - Weißenberger, Manuel A1 - Jakuscheit, Axel A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Trends in computer-assisted surgery for total knee arthroplasty in Germany: an analysis based on the operative procedure classification system between 2010 to 2021 JF - Journal of Clinical Medicine N2 - Alignment strategies for primary total knee arthroplasty (TKA) have changed significantly over time with a shift towards a more individualized alignment goal. At the same time, computer-assisted surgery (CAS) has gained interest for intraoperative control and accuracy in implant positioning and limb alignment. Despite the often discussed benefits and drawbacks of robotics and navigation for TKA, the routine use of these new devices on a day-to-day basis remains obscure. Therefore, nationwide hospital billing data based on the Operation Procedure Classification System (OPS) were retrieved from the Federal Statistical Office of Germany for the period from 2010 to 2021. OPS codes for primary total knee arthroplasty (OPS code: 5-822*) were further analyzed regarding the usage of computer navigation (additional OPS code: 5-988) or robotic devices (additional OPS code: 5-987). Gender and age at the time of surgery were also assessed. The results show a total of 2,226,559 primary TKAs were implanted between 2010 and 2021, of which 2,044,914 were performed conventionally (91.84% of all TKAs). A total of 170,276 TKAs were performed using navigation technique (7.65% of all TKAs) and another 11,369 TKAs were performed using robotics (0.51% of all TKAs). For the period from 2018 to 2021, a substantial increase in robot-assisted TKA (R-TKA) was observed, with an average increase rate of 84.74% per year, while the number of navigated TKAs declined (−3.67% per year). Computer-assisted surgery, and particularly robotics for TKA, are seeing growing popularity and stepwise translation into routine clinical use in Germany, with a steep increase rate of more than 80% per year since 2018. Nevertheless, the majority of TKAs are still performed using manual instrumentation, rendering conventional TKA the currently unchanged gold standard. KW - robotic KW - TKA KW - knee replacement KW - computer navigation KW - Germany Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-304879 SN - 2077-0383 VL - 12 IS - 2 ER - TY - JOUR A1 - Heinz, Tizian A1 - Eidmann, Annette A1 - Jakuscheit, Axel A1 - Laux, Tino A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Demographics and trends for inbound medical tourism in Germany for orthopedic patients before and during the COVID-19 pandemic JF - International Journal of Environmental Research and Public Health N2 - Medical tourism is a rapidly growing sector of economic growth and diversification. However, data on the demographics and characteristics of the traveling patients are sparse. In this study, we analyzed the common demographic properties and characteristics of the inbound medical tourists seeking orthopedic medical care in Germany for the years 2010 to 2019 compared to a domestic group. At the same time, we examined how the COVID-19 pandemic outbreak of 2020 changed the field of medical tourism in Germany. Calculations were performed using administrative hospital data provided by the Federal Statistical Department of Germany. Data were analyzed from the years 2010 to 2020. A total of six elective orthopedic surgery codes (bone biopsy, knee arthroplasty, foot surgery, osteotomy, hardware removal, and arthrodesis) were identified as key service indicators for medical tourism and further analyzed. Factors including residence, sex, year, and type of elective surgery were modeled using linear regression analysis. Age and sex distributions were compared between patients living inside Germany (DE) or outside Germany (non-DE). Between 2010 and 2020, 6,261,801 orthopedic procedures were coded for the DE group and 27,420 key procedures were identified for the non-DE group. Medical tourists were predominantly male and significantly younger than the domestic population. The linear regression analysis of the OPS codes over the past years showed a significantly different slope between the DE and non-DE groups only for the OPS code “hardware removal”. With the COVID-19 pandemic, an overall decline in performed orthopedic procedures was observed for the non-DE and the DE group. A significant reduction below the 95% prediction bands for the year 2020 could be shown for hardware removal and foot surgery (for DE), and for hardware removal, knee arthroplasty, foot surgery, and osteotomy (for non-DE). This study is the first to quantify inbound medical tourism in elective orthopedic surgery in Germany. The COVID-19 pandemic negatively affected many — but not all — areas of orthopedic surgery. It has to be seen how this negative trend will develop in the future. KW - inbound medical tourism KW - orthopedic surgery KW - Germany KW - COVID-19 KW - pandemic Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-304955 SN - 1660-4601 VL - 20 IS - 2 ER - TY - JOUR A1 - Heinz, Tizian A1 - Meller, Felix A1 - Luetkens, Karsten Sebastian A1 - Anderson, Philip Mark A1 - Stratos, Ioannis A1 - Horas, Konstantin A1 - Rudert, Maximilian A1 - Reppenhagen, Stephan A1 - Weißenberger, Manuel T1 - The AMADEUS score is not a sufficient predictor for functional outcome after high tibial osteotomy JF - Journal of Experimental Orthopaedics N2 - Purpose The Area Measurement And Depth Underlying Structures (AMADEUS) classification system has been proposed as a valuable tool for magnetic resonance (MR)-based grading of preoperatively encountered chondral defects of the knee joint. However, the potential relationship of this novel score with clinical data was yet to determine. It was the primary intention of this study to assess the correlative relationship of the AMADEUS with patient reported outcome scores in patients undergoing medial open-wedge high tibial valgus osteotomy (HTO). Furthermore, the arthroscopic ICRS (International Cartilage Repair Society) grade evaluation was tested for correlation with the AMADEUS classification system. Methods This retrospective, monocentric study found a total of 70 individuals that were indicated for HTO due to degenerative chondral defects of the medial compartment between 2008 and 2019. A preoperative MR image as well as a pre-osteotomy diagnostic arthroscopy for ICRS grade evaluation was mandatory for all patients. The Knee Osteoarthritis Outcome Score (KOOS) including its five subscale scores (KOOS-ADL, KOOS-QOL, KOOS-Sports, KOOS-Pain, KOOS-Symptoms) was obtained preoperatively and at a mean follow-up of 41.2 ± 26.3 months. Preoperative chondral defects were evaluated using the AMADEUS classification system and the final AMADEUS scores were correlated with the pre- and postoperative KOOS subscale sores. Furthermore, arthroscopic ICRS defect severity was correlated with the AMADEUS classification system. Results There was a statistically significant correlation between the AMADEUS BME (bone marrow edema) subscore and the KOOS Symptoms subscore at the preoperative visit (r = 0.25, p = 0.04). No statistically significant monotonic association between the AMADEUS total score and the AMADEUS grade with pre- and postoperative KOOS subscale scores were found. Intraoperatively obtained ICRS grade did reveal a moderate correlative relation with the AMADEUS total score and the AMADEUS grade (r = 0.28, p = 0.02). Conclusions The novel AMADEUS classification system largely lacks correlative capacity with patient reported outcome measures in patients undergoing HTO. The MR tomographic appearance of bone marrow edema is the only parameter predictive of the clinical outcome at the preoperative visit. KW - cartilage KW - AMADEUS KW - KOOS KW - knee KW - high tibial osteotomy KW - chondral defect KW - osteoarthritis KW - PROM KW - correlation Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-357765 VL - 10 ER - TY - JOUR A1 - Heinz, Tizian A1 - Meller, Felix A1 - Luetkens, Karsten Sebastian A1 - Horas, Konstantin A1 - Schäfer, Thomas A1 - Rudert, Maximilian A1 - Reppenhagen, Stephan A1 - Weißenberger, Manuel T1 - Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system? JF - Journal of Experimental Orthopaedics N2 - Purpose The AMADEUS (Area Measurement And DEpth and Underlying Structures) scoring and grading system has been proposed for the MRI based evaluation of untreated focal chondral defects around the knee. The clinical practicability, its correlation with arthroscopically assessed grading systems (ICRS – International Cartilage Repair Society) and thereby its clinical value in terms of decision making and guiding prognosis was yet to determine. Methods From 2008 to 2019 a total of 89 individuals were indicated for high tibial valgus osteotomy (HTO) due to tibial varus deformity and concomitant chondral defects of the medial compartment of the knee. All patients received a preoperative MRI (1.5 Tesla or 3.0 Tesla) and pre-osteotomy diagnostic arthroscopy. Chondral defects of the medial compartment were scored and graded with the MRI based AMADEUS by three independent raters and compared to arthroscopic defect grading by the ICRS system. Interrater and intrarater reliability as well as correlation analysis with the ICRS classification system were assessed. Results Intraclass correlation coefficients for the various subscores of the AMADEUS showed an overall good to excellent interrater agreement (min: 0.26, max: 0.80). Intrarater agreement turned out to be substantially inferior (min: 0.08, max: 0.53). Spearman correlation revealed an overall moderate correlative association of the AMADEUS subscores with the ICRS classification system, apart from the defect area subscore. Sensitivity of the AMADEUS to accurately identify defect severity according to the ICRS was 0.7 (0.69 for 3.0 Tesla MRI, 0.67 for 1.5 Tesla MRI). The mean AMADEUS grade was 2.60 ± 0.81 and the mean ICRS score 2.90 ± 0.63. Conclusions Overall, the AMADEUS with all its subscores shows moderate correlation with the arthroscopic chondral grading system according to ICRS. This suggests that chondral defect grading by means of the MRI based AMADEUS is well capable of influencing and guiding treatment decisions. Interrater reliability shows overall good agreement. KW - MRI KW - knee KW - cartilage defect KW - grading system of chondral defects KW - AMADEUS KW - ICRS Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300781 SN - 2197-1153 VL - 9 IS - 1 ER -