TY - THES A1 - Portmann, Johannes T1 - Accelerated inversion recovery MRI of the myocardium using spiral acquisition T1 - Beschleunigte Inversion-Recovery MR-Bildgebung des Myokards mit spiralen Auslesezügen N2 - This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality. N2 - Diese Arbeit behandelt die Beschleunigung der kardiovaskulären MRT zum Erfassen funktioneller Information bei Steady-State-Kontrast und zur Unter- suchung der Vitalität bei Wiederherstellung der Magnetisierung nach ihrer Inversion. Zwei Ansätze werden eingeführt und im Detail diskutiert: MOCO- MAP, welches ein exponentielles Modell nutzt, um dynamische Daten zu rekonstruieren, und IR-CRISPI, welches mit seinem “low-rank plus sparse"- Algorithmus mit Compressed Sensing verwandt ist. MOCO-MAP ist der Nachfolger der modellbasierten Beschleunigung des Parameter-Mappings (MAP) für die Anwendung im Bereich des Myokards. Hierzu wurde es mit einer Bewegungskorrektur (MOCO) versehen, um expo- nentielles Fitten eines unbewegten Objects in Zeitrichtung zu ermöglichen. Das Einbringen dieses physikalischen Vorwissens zusammen mit dem Erzwin- gen von Konsistenz mit den Messdaten wird dazu genutzt, iterativ eine Bildfolge aus Daten einer deutlich kürzeren Messung als herkömmlich zu rekonstruieren (< 3 s gegenüber ca. 10 s). Die Ergebnisse zeigen die Umsetz- barkeit der Methode sowie die Nachweisbarkeit von Delayed Enhancements im Myokard, aber deutliche funktionelle Abweichungen und Artefakte bereits aufgrund von kleinen Ungenauigkeiten der Bewegungskorrektur. IR-CRISPI geht aus CRISPI hervor, welches zur Auswertung von funk- tionellen Echtzeitdaten bei konstantem Kontrast dient. Mit der Rekon- struktion durch getrennte Berechnung von niedrigrangigem und dünnbe- setztem Matrixanteil wird hier bei der Datenrekonstruktion weniger stark eingeschränkt als bei einem strikten exponentiellen Modell. Die pirale Auf- nahmeweise erlaubt hierzu ausreichend effiziente k-Raumabdeckung. Die “low-rank plus sparse"-Rekonstruktion ist kompatibel mit dynamischen und mit Inversion-Recovery-Daten. Eine Bewegungskorrektur ist folglich nicht nötig. IR-CRISPI wurde mit einer Rauschunterdrückung durch räumliche Wavelet- Filterung versehen. Eine Studie, die 10 Patienten einschließt, zeigt die Eignung für die medizinische Anwendung. Der Vergleich mit herkömm- lichen Aufnahmetechniken lässt auf den gewonnenen diagnostischen Nutzen schließen. Besonders für Patienten, die Schwierigkeiten mit dem Luftanhal- ten haben, eröffnet diese Echtzeitaufnahmemethode eine wertvolle Alterna- tive und erhöhte Stabilität. Am Ende konnte gerade mittels IR-CRISPI eine bemerkenswerte Beschleu- nigung der kardiovaskulären MR-Untersuchung verwirklicht werden. Trotz der kurzen Aufnahmezeit von weniger als 100 s für den kompletten linken Ven- trikel schließt es nicht nur die Information zweier herkömmlicher Protokolle mit ein (Cine und LGE), die zusammen mehr als 9,6 min dauern, sondern es erlaubt zusätzlich auch das Einstellen der TI-Zeit im Nachhinein und liefert Ergebnisse mit geringerem Artefaktlevel bei ähnlicher Bildqualität KW - Kernspintomografie KW - Herzfunktion KW - Herzmuskel KW - Bildgebendes Verfahren KW - Echtzeit KW - cine loop KW - late enhancement KW - late gadolinium-enhancement KW - magnetic resonance imaging KW - real-time imaging KW - spiral trajectory Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-302822 ER - TY - RPRT A1 - Grigorjew, Alexej A1 - Metzger, Florian A1 - Hoßfeld, Tobias A1 - Specht, Johannes A1 - Götz, Franz-Josef A1 - Chen, Feng A1 - Schmitt, Jürgen T1 - Asynchronous Traffic Shaping with Jitter Control N2 - Asynchronous Traffic Shaping enabled bounded latency with low complexity for time sensitive networking without the need for time synchronization. However, its main focus is the guaranteed maximum delay. Jitter-sensitive applications may still be forced towards synchronization. This work proposes traffic damping to reduce end-to-end delay jitter. It discusses its application and shows that both the prerequisites and the guaranteed delay of traffic damping and ATS are very similar. Finally, it presents a brief evaluation of delay jitter in an example topology by means of a simulation and worst case estimation. KW - Echtzeit KW - Rechnernetz KW - Latenz KW - Ethernet KW - TSN KW - jitter KW - traffic damping Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-205824 ER - TY - RPRT A1 - Grigorjew, Alexej A1 - Metzger, Florian A1 - Hoßfeld, Tobias A1 - Specht, Johannes A1 - Götz, Franz-Josef A1 - Schmitt, Jürgen A1 - Chen, Feng T1 - Technical Report on Bridge-Local Guaranteed Latency with Strict Priority Scheduling N2 - Bridge-local latency computation is often regarded with caution, as historic efforts with the Credit-Based Shaper (CBS) showed that CBS requires network wide information for tight bounds. Recently, new shaping mechanisms and timed gates were applied to achieve such guarantees nonetheless, but they require support for these new mechanisms in the forwarding devices. This document presents a per-hop latency bound for individual streams in a class-based network that applies the IEEE 802.1Q strict priority transmission selection algorithm. It is based on self-pacing talkers and uses the accumulated latency fields during the reservation process to provide upper bounds with bridge-local information. The presented delay bound is proven mathematically and then evaluated with respect to its accuracy. It indicates the required information that must be provided for admission control, e.g., implemented by a resource reservation protocol such as IEEE 802.1Qdd. Further, it hints at potential improvements regarding new mechanisms and higher accuracy given more information. KW - Echtzeit KW - Rechnernetz KW - Latenz KW - Ethernet KW - Latency Bound KW - Formal analysis Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-198310 ER - TY - THES A1 - Stamm, Heimo Helmut T1 - Parallele Echtzeitbildgebung zur Quantifizierung der linksventrikulären Herzfunktion bei freier Atmung mittels MRT T1 - Cardiac functional parameters determined under free breathing by untriggered real-time MR acquisition N2 - MRT-Untersuchungen des Herzens haben in den letzten Jahren an Häufigkeit und Bedeutung zugenommen. Die Nachfrage nach schnelleren und für den Patienten komfortableren Sequenzen steigt. Diese Arbeit untersucht, ob es mit Hilfe von parallelen Echtzeitsequenzen ohne EKG-Triggerung möglich ist, die Untersuchungszeit deutlich zu verkürzen und dabei gut reproduzierbare Messwerte zu erhalten. Hierzu wurden 9 Probanden und 21 Patienten mit A) paralleler Echtzeitbildgebung bei freier Atmung und B)einer Standard CINE Sequenz mit Atemstopp untersucht. Zur statistischen Analyse beider Methoden dienten Bland-Altman-Plots. Um Aussagen über die Reproduzierbarkeit der Ergebnisse treffen zu können wurde außerdem die Variabilität der Messungen bestimmt. Die Messzeit der neuen Echtzeitsequenz war um mehr als das zehnfache kürzer als die einer herkömmlichen CINE Sequenz. Die Ergebnisse waren mit der Standard CINE Sequenz vergleichbar und zeigten nur einen geringe Variabilität. Lediglich die linksventrikuläre Masse wurde im Gesamtkollektiv leicht überschätzt. Insgesamt scheint die Echtzeitbildgebung aufgrund der zuverlässigen Ergebnisse für den Klinikalltag geeignet. Insbesondere Patienten mit Atemnot, Herzrhythmusstörungen oder aber Kinder könnten profitieren. N2 - The increasing frequency of LV functional MRI studies demands for faster methods and for more comfort for the patient. The purpose of this work was to assess whether real-time (RT) non ECG triggered MRI allows a considerable shortening of examination time in high reproducibility. RT and standard ECG-triggered breathhold cine MRI was acquired in 9 volunteers and 21 patients. Differences between both methods were assessed by Bland-Altman analyses including variability studies. Compared to standard cine MRI, RT decreased data acquisition time by more than the factor of ten. RT produced comparable results except for a slight overestimation of LV mass. Interstudy and intraobserver variability of RT cine showed a low variability. Consequently, free-breathing RT cine proved to be a reliable and suitable tool for clinical routine and may be particularly relevant in patients with sub-optimal breath-holding ability, arrhythmia or childern. KW - MRT KW - Echtzeit KW - CINE KW - Herz KW - Atmung KW - MRT KW - Echtzeit KW - CINE KW - Herz KW - Atmung KW - real-time KW - CINE KW - MRI KW - cardiac breathing Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-47900 ER -