TY - JOUR A1 - Chaudry, Oliver A1 - Grimm, Alexandra A1 - Friedberger, Andreas A1 - Kemmler, Wolfgang A1 - Uder, Michael A1 - Jakob, Franz A1 - Quick, Harald H. A1 - von Stengel, Simon A1 - Engelke, Klaus T1 - Magnetic Resonance Imaging and Bioelectrical Impedance Analysis to Assess Visceral and Abdominal Adipose Tissue JF - Obesity N2 - Objective This study aimed to compare a state‐of‐the‐art bioelectrical impedance analysis (BIA) device with two‐point Dixon magnetic resonance imaging (MRI) for the quantification of visceral adipose tissue (VAT) as a health‐related risk factor. Methods A total of 63 male participants were measured using a 3‐T MRI scanner and a segmental, multifrequency BIA device. MRI generated fat fraction (FF) maps, in which VAT volume, total abdominal adipose tissue volume, and FF of visceral and total abdominal compartments were quantified. BIA estimated body fat mass and VAT area. Results Coefficients of determination between abdominal (r\(^{2}\) = 0.75) and visceral compartments (r\(^{2}\) = 0.78) were similar for both groups, but slopes differed by a factor of two. The ratio of visceral to total abdominal FF was increased in older men compared with younger men. This difference was not detected with BIA. MRI and BIA measurements of the total abdominal volume correlated moderately (r\(^{2}\) = 0.31‐0.56), and visceral measurements correlated poorly (r\(^{2}\) = 0.13‐0.44). Conclusions Visceral BIA measurements agreed better with MRI measurements of the total abdomen than of the visceral compartment, indicating that BIA visceral fat area assessment cannot differentiate adipose tissue between visceral and abdominal compartments in young and older participants. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-213591 VL - 28 IS - 2 SP - 277 EP - 283 ER - TY - JOUR A1 - Wagenbrenner, Mike A1 - Heinz, Tizian A1 - Horas, Konstantin A1 - Jakuscheit, Axel A1 - Arnholdt, Joerg A1 - Mayer-Wagner, Susanne A1 - Rudert, Maximilian A1 - Holzapfel, Boris M. A1 - Weißenberger, Manuel T1 - Impact of Tranexamic Acid on Chondrocytes and Osteogenically Differentiated Human Mesenchymal Stromal Cells (hMSCs) In Vitro JF - Journal of Clinical Medicine N2 - The topical application of tranexamic acid (TXA) helps to prevent post-operative blood loss in total joint replacements. Despite these findings, the effects on articular and periarticular tissues remain unclear. Therefore, this in vitro study examined the effects of varying exposure times and concentrations of TXA on proliferation rates, gene expression and differentiation capacity of chondrocytes and human mesenchymal stromal cells (hMSCs), which underwent osteogenic differentiation. Chondrocytes and hMSCs were isolated and multiplied in monolayer cell cultures. Osteogenic differentiation of hMSCs was induced for 21 days using a differentiation medium containing specific growth factors. Cell proliferation was analyzed using ATP assays. Effects of TXA on cell morphology were examined via light microscopy and histological staining, while expression levels of tissue-specific genes were measured using semiquantitative RT-PCR. After treatment with 50 mg/mL of TXA, a decrease in cell proliferation rates was observed. Furthermore, treatment with concentrations of 20 mg/mL of TXA for at least 48 h led to a visible detachment of chondrocytes. TXA treatment with 50 mg/mL for at least 24 h led to a decrease in the expression of specific marker genes in chondrocytes and osteogenically differentiated hMSCs. No significant effects were observed for concentrations beyond 20 mg/mL of TXA combined with exposure times of less than 24 h. This might therefore represent a safe limit for topical application in vivo. Further research regarding in vivo conditions and effects on hMSC functionality are necessary to fully determine the effects of TXA on articular and periarticular tissues. KW - tranexamic acid KW - hMSCs KW - chondrocytes KW - osteoarthritis KW - toxicity KW - differentiation capacity Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-219410 SN - 2077-0383 VL - 9 IS - 12 ER - TY - JOUR A1 - Liedtke, Daniel A1 - Hofmann, Christine A1 - Jakob, Franz A1 - Klopocki, Eva A1 - Graser, Stephanie T1 - Tissue-Nonspecific Alkaline Phosphatase—A Gatekeeper of Physiological Conditions in Health and a Modulator of Biological Environments in Disease JF - Biomolecules N2 - Tissue-nonspecific alkaline phosphatase (TNAP) is a ubiquitously expressed enzyme that is best known for its role during mineralization processes in bones and skeleton. The enzyme metabolizes phosphate compounds like inorganic pyrophosphate and pyridoxal-5′-phosphate to provide, among others, inorganic phosphate for the mineralization and transportable vitamin B6 molecules. Patients with inherited loss of function mutations in the ALPL gene and consequently altered TNAP activity are suffering from the rare metabolic disease hypophosphatasia (HPP). This systemic disease is mainly characterized by impaired bone and dental mineralization but may also be accompanied by neurological symptoms, like anxiety disorders, seizures, and depression. HPP characteristically affects all ages and shows a wide range of clinical symptoms and disease severity, which results in the classification into different clinical subtypes. This review describes the molecular function of TNAP during the mineralization of bones and teeth, further discusses the current knowledge on the enzyme’s role in the nervous system and in sensory perception. An additional focus is set on the molecular role of TNAP in health and on functional observations reported in common laboratory vertebrate disease models, like rodents and zebrafish. KW - TNAP KW - hypophosphatasia KW - HPP KW - zebrafish KW - mineralization KW - ALPL KW - craniosynostosis KW - teeth KW - nervous system Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-220096 SN - 2218-273X VL - 10 IS - 12 PB - MDPI ER - TY - JOUR A1 - Herrmann, Marietta A1 - Diederichs, Solvig A1 - Melnik, Svitlana A1 - Riegger, Jana A1 - Trivanović, Drenka A1 - Li, Shushan A1 - Jenei-Lanzl, Zsuzsa A1 - Brenner, Rolf E. A1 - Huber-Lang, Markus A1 - Zaucke, Frank A1 - Schildberg, Frank A. A1 - Grässel, Susanne T1 - Extracellular Vesicles in Musculoskeletal Pathologies and Regeneration JF - Frontiers in Bioengineering and Biotechnology N2 - The incidence of musculoskeletal diseases is steadily increasing with aging of the population. In the past years, extracellular vesicles (EVs) have gained attention in musculoskeletal research. EVs have been associated with various musculoskeletal pathologies as well as suggested as treatment option. EVs play a pivotal role in communication between cells and their environment. Thereby, the EV cargo is highly dependent on their cellular origin. In this review, we summarize putative mechanisms by which EVs can contribute to musculoskeletal tissue homeostasis, regeneration and disease, in particular matrix remodeling and mineralization, pro-angiogenic effects and immunomodulatory activities. Mesenchymal stromal cells (MSCs) present the most frequently used cell source for EV generation for musculoskeletal applications, and herein we discuss how the MSC phenotype can influence the cargo and thus the regenerative potential of EVs. Induced pluripotent stem cell-derived mesenchymal progenitor cells (iMPs) may overcome current limitations of MSCs, and iMP-derived EVs are discussed as an alternative strategy. In the last part of the article, we focus on therapeutic applications of EVs and discuss both practical considerations for EV production and the current state of EV-based therapies. KW - extracellular vesicles KW - exosomes KW - musculoskeletal diseases KW - MSC KW - iMP KW - cell-free therapeutics Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-222882 SN - 2296-4185 VL - 8 ER - TY - JOUR A1 - Genest, Franca A1 - Rak, Dominik A1 - Petryk, Anna A1 - Seefried, Lothar T1 - Physical Function and Health‐Related Quality of Life in Adults Treated With Asfotase Alfa for Pediatric‐Onset Hypophosphatasia JF - JBMR Plus N2 - Hypophosphatasia (HPP) is a rare, inherited, metabolic disease characterized by tissue‐nonspecific alkaline phosphatase deficiency resulting in musculoskeletal and systemic clinical manifestations. This observational study evaluated the effectiveness of enzyme replacement therapy with asfotase alfa on physical function and health‐related quality of life (HRQoL) among adults with pediatric‐onset HPP who received asfotase alfa for 12 months at a single center (ClinicalTrial.gov no.: NCT03418389). Primary outcomes evaluated physical function with the 6‐minute walk test (6MWT), timed up‐and‐go (TUG) test, Short Physical Performance Battery (SPPB), and handheld dynamometry (HHD). Secondary outcome measures included the Lower Extremity Functional Scale (LEFS), pain prevalence/intensity, and pain medication use; HRQoL was evaluated using the 36‐Item Short‐Form Health Survey version 2 (SF‐36v2). Safety data were collected throughout the study. All 14 patients (11 women) had compound heterozygous ALPL gene mutations and ≥1 HPP bone manifestation, including history of ≥1 fracture. Mean (min, max) age was 51 (19 to 78) years. From baseline to 12 months of treatment, median 6MWT distance increased from 267 m to 320 m (n = 13; p = 0.023); median TUG test time improved from 14.4 s to 11.3 s (n = 9; p = 0.008). Specific components of the SPPB also improved significantly: median 4‐m gait speed increased from 0.8 m/s to 1.1 m/s (n = 10; p = 0.007) and median repeated chair‐rise time improved from 22 s to 13 s (n = 9; p = 0.008). LEFS score improved from 24 points to 53 points (n = 10; p = 0.002). Improvements in HHD were not clinically significant. SF‐36v2 Physical Component Score (PCS) improved after 12 months of treatment (n = 9; p = 0.010). Pain level did not change significantly from baseline to 12 months of treatment. There were significant improvements on chair‐rise time and SF‐36v2 PCS by 3 months, and on TUG test time after 6 months. No new safety signals were identified. These results show the real‐world effectiveness of asfotase alfa in improving physical functioning and HRQoL in adults with pediatric‐onset HPP. © 2020 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research. KW - hypophosphatasia KW - enzyme replacement therapy KW - physical performance KW - clinical study KW - real-world evidence Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-218410 VL - 4 IS - 9 ER - TY - THES A1 - Huber, Simon T1 - Klinisch-radiologische Evaluation des Merete® BioBall™-Adapter-Systems in der Hüftendoprothetik T1 - Outcome of a modular head-neck adapter system in hip arthroplasty N2 - Die Revisionsendoprothetik des Hüftgelenkes ist eine große Herausforderung, insbesondere bei Teilwechseln von Komponenten bei fest-implantiertem Schaft. In einer retrospektiven Analyse wurde eine Implantat-Komponente des Medizinprodukteherstellers Merete Medical (Berlin) untersucht. Ziel der Untersuchung war es, eine Aussage über die Stabilität des Implantats und den klinischen Versorgungserfolg bei dessen Verwendung treffen zu können. Es wurden Daten von insgesamt 72 Patienten erhoben. Es erfolgte eine klinische und radiologische Nachuntersuchung. Die Daten wurden einer deskriptiven und explorativen Analyse unterzogen, eine Überlebenszeitanalyse wurde durchgeführt. Das Implantat zeigte mechanische Stabilität in einem mittelfristigen Zeitraum. Der Versorgungserfolg (gemessen am Harris Hip Score) war durchschnittlich bis gut. Es zeigten sich Zusammenhänge zwischen dem präoperativen Zustand der Patienten und dem Versorgungerfolg. N2 - Revision hip arthroplasty remains a challenging task, especially when it comes to a partial exchange of components with a well-fixed stem. A retrospective analysis was performed to investigate an implant component of Merete Medical (Berlin). The aim of the study was to determine the mechanical stability and quality of care by use of the implant. Data of 72 patients were collected by conducting clinical and radiological follow-up examinations. The collected data were used for an extensive analysis. The implant showed mechanical stability during a middle-term period. The quality of care was good to average (measured by Harris Hip Score). A relation between the preoperative condition and the quality of care was found. KW - Endoprothetik KW - Hüfte KW - Revision KW - modular KW - Merete KW - Revision KW - Hip Arthroplasty KW - Implant Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-228643 ER - TY - JOUR A1 - Prodinger, Peter Michael A1 - Lazic, Igor A1 - Horas, Konstantin A1 - Burgkart, Rainer A1 - von Eisenhart-Rothe, Rüdiger A1 - Weissenberger, Manuel A1 - Rudert, Maximilian A1 - Holzapfel, Boris Michael T1 - Revision Arthroplasty Through the Direct Anterior Approach Using an Asymmetric Acetabular Component JF - Journal of Clinical Medicine N2 - Despite increasing numbers of primary hip arthroplasties performed through the direct anterior approach (DAA), there is a lack of literature on DAA revision arthroplasty. The present study was performed in order to evaluate outcomes and revision rates after revision through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation. In a retrospective cohort study, we analyzed prospectively collected data of 57 patients (61 hips, 43 female, 18 male) who underwent aseptic acetabular component revision through the DAA with the abovementioned implant system between January 2015 and December 2017. The mean follow-up was 40 months (12–56). Survival rates were estimated using the Kaplan–Meier method. All complications were documented and functional outcomes were assessed pre- and postoperatively. Kaplan–Meier analysis revealed an estimated five-year implant survival of 97% (confidence interval CI 87–99%). The estimated five-year survival with revision for any cause was 93% (CI 83–98%). The overall revision rate was 6.6% (n = 4). Two patients had to undergo revision due to periprosthetic infection (3.3%). In one patient, the acetabular component was revised due to aseptic loosening four months postoperatively. Another patient suffered from postoperative iliopsoas impingement and was treated successfully by arthroscopic iliopsoas tenotomy. Two (3.3%) of the revised hips dislocated postoperatively. The mean Harris Hip Score improved from 35 (2–66) preoperatively to 86 (38–100) postoperatively (p < 0.001). The hip joint’s anatomical center of rotation was restored at a high degree of accuracy. Our findings demonstrate that acetabular revision arthroplasty through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation is safe and practicable, resulting in good radiographic and clinical midterm results. KW - anterior approach KW - revision arthroplasty KW - hip joint KW - acetabular bone defect KW - asymmetric implant KW - anatomic center of rotation Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-213184 SN - 2077-0383 VL - 9 IS - 9 ER - TY - THES A1 - Schillinger, Judith Hanna T1 - Schmerzen und ihre Therapie in der Hüftendoprothetik. Eine retrospektive Studie zum Vergleich des minimal-invasiven direkt anterioren mit dem transglutealen Zugang nach Bauer T1 - Pain and its therapy in hip arthroplasty. A retrospective study comparing the minimally invasive direct anterior approach with the transgluteal approach according to Bauer N2 - Hintergrund: Die Entwicklung minimal-invasiver gewebeschonender Zugangswege in der Hüftendoprothetik ist im Allgemeinen mit einer schnelleren Rehabilitation, einer Verringerung der postoperativen Schmerzen und einem erhöhten Patientenkomfort verbunden. Das Ziel dieser Studie war es, einen anterioren minimal-invasiven mit einem transglutealen lateralen Zugangsweg für Hüftgelenksersatzoperationen in Bezug auf postoperatives Schmerzniveau, den Schmerzmittelgebrauch, die Länge des Krankenhausaufenthalts und die Zeit bis zum Erreichen eines definierten physiotherapeutischen Therapiezieles zu vergleichen. Methoden: In dieser retrospektiven Kohortenstudie untersuchten wir 200 Patienten, die sich einer Hüftendoprothesenimplantation unterzogen. Gruppe I (n = 100) erhielt einen minimal-invasiven anterioren Hüftzugang (modifiziert nach Smith-Peterson), Gruppe II (n = 100) erhielt einen lateralen transglutealen Zugang (nach Bauer). Die Untersuchungsziele waren der Schmerz in Ruhe und während der Physiotherapie, der Schmerzmittelgebrauch, die Länge des stationären Aufenthaltes sowie die Zeitdauer bis zum Erreichen des physiotherapeutischen Therapiezieles. Ergebnisse: Die Patienten der Gruppe I konsumierten weniger Schmerzmedikamente (19,6 ± 6,9 mg Piritramid gegenüber 23,6 ± 11,3 mg; p = 0,005) und hatten in der frühen postoperativen Phase weniger Schmerzen (Operationstag: VAS 1,3 ± 1 gegenüber 2,3 ± 1,3, p = 0,0001, erster postoperativer Tag: VAS 0,41 ± 0,8 vs. 0,66 ± 1,1, p = 0,036). Die Zeit bis zum Erreichen des definierten Therapiezieles (6,4 ± 2 Tage gegenüber 7,4 ± 2,1 Tagen; p = 0,001) und die Dauer des Krankenhausaufenthalts waren kürzer (10,2 ± 1,9 Tage gegenüber 13,4 ± 1,6 Tagen; p = 0,0001) für Gruppe I. Die Schmerzen während der Physiotherapie waren jedoch am dritten und sechsten bis neunten Tag nach der Operation im Vergleich zu Gruppe II höher (p = 0,001–0,013). Schlussfolgerung: Die Implantation einer Hüftprothese über einen minimal-invasiven anterioren Zugang führt in der direkt postoperativen Phase zu einer Reduktion des Schmerzniveaus und des Schmerzmittelgebrauchs. Zusätzlich werden das Erreichen des physiotherapeutischen Therapiezieles und die Länge des stationären Aufenthaltes positiv beeinflusst. Den höheren Schmerzen während der Physiotherapie könnte durch eine Reduktion der erlaubten Gewichtsbelastung in der frühen postoperativen Phase entgegengewirkt werden. N2 - Purpose: The development of minimal-incision techniques for total hip replacement with preservation of soft tissue is generally associated with faster rehabilitation, reduction of postoperative pain and increased patient comfort. The aim of this study was to compare a minimal-incision anterior approach with a transgluteal lateral technique for hip replacement surgery with respect to postoperative pain, consumption of rescue medication, length of hospital stay and time to reach a defined range of motion. Methods: In this retrospective cohort study we investigated 100 patients with a minimal-incision anterior approach (group I) and 100 patients with a transgluteal lateral approach (group II) retrospectively undergoing unilateral hip replacement. The study variables were pain at rest and during physiotherapy, amount of rescue medication, the time to reach a defined flexion and time in hospital. Results: The patients of group I consumed less rescue medication (19.6 ± 6.9 mg vs. 23.6 ± 11.3 mg;  p = 0.005) and experienced less pain on the day of surgery (1.3 ± 1 vs. 2.3 ± 1.3, p = 0.0001) and the first postoperative day (0.41 ± 0.8 vs. 0.66 ± 1.1, p = 0.036). The time to reach the defined range of motion (6.4 ± 2 days vs. 7.4 ± 2.1 days; p = 0.001) and the length of hospital stay were shorter (10.2 ± 1.9 days vs. 13.4 ± 1.6 days; p = 0.0001) for group I. However, pain during physiotherapy was higher on the third and sixth through ninth days after surgery in comparison to group II (p = 0.001–0.013). Conclusion: The implantation of a hip prosthesis through a minimal-incision anterior approach is successful in reducing postoperative pain and consumption of pain medication. Time to recovery and length of hospital stay are also influenced positively. Pain increases during physiotherapy, and may be mitigated by adopting limited weight bearing during the early postoperative period. KW - minimal-invasiv KW - vorderer Zugang KW - Hüftendoprothetik KW - Postoperativer Schmerz KW - minimally invasiv KW - THA KW - anterior approach KW - total hip arthroplasty KW - postoperative pain KW - minimalinvasive KW - hip KW - arthroplasty Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-225745 ER - TY - THES A1 - Kramer, Lisa Sophie T1 - Charakterisierung des Einflusses von Estrogenrezeptoren auf mechanoresponsive Reporter T1 - Characterization of the influence of estrogen receptors according to mechanoresponsive reporter N2 - Osteoporose wird definiert als erworbene, generalisierte Skeletterkrankung, die durch eine verminderte Knochenfestigkeit und einen pathologischen Knochenverlust charakterisiert wird. Durch die Störung der Mikroarchitektur kommt es zu strukturellen und funktionellen Defiziten im Sinne von Fragilitätsfrakturen. Mechanische Stimulation erhält die Gewebemasse und stimuliert deren kontinuierliche Anpassung. Östrogene spielen bei der Entwicklung, dem Wachstum und der Regeneration des Knochens eine bedeutende Rolle und wirken über Bindung an die Östrogenrezeptoren ER und ER in bestimmten Zielgeweben. Östrogenrezeptoren sind unverändert sehr geeignete Targets für die Entwicklung von Medikamenten im Rahmen der Osteoporosetherapie wie z.B. die selektiven Östrogen-Rezeptor-Modulatoren (SERMs). Die molekulare Klärung der Einflüsse von ER und ER ist unverändert von großer klinischer Bedeutung. Die Herstellung stabiler Zelllinien mit Überexpression von Reportergenkonstrukten und Rezeptoren kann dabei hilfreich sein. In dieser Arbeit wurde eine stabile Zelllinie mit Überexpression von ERβ etabliert, die unterschiedliche Wirkung von ER und ER wurden analysiert und die Effekte von zyklischer Dehnung auf Reportergenexpression unter der Kontrolle von mechanosensitiven responsiven Elementen wurden charakterisiert. N2 - Osteoporosis is defined as an acquired, generalized skeletal disorder which is characterized by reduced bone stability and pathological bone loss. A disorder of the microarchitecture leads to structural and functional deficiencies in the form of fragility fractures. Mechanical strain sustains tissue and stimulates its continuous adaptation. Estrogen plays an important role in the development, growth and regeneration of bones and works by binding to the estrogen receptors ERα und ERβ in certain target tissues. Estrogen receptors continue to be significant targets in the development of pharmaceuticals for osteoporosis therapy as for example selective estrogen receptor modulators (SERMs). The clarification of the influence of ERα and ERβ on a molecular level continue to be of great clinical significance. The creation of stable cell lines with overexpression of reporter gene constructs and receptors can be helpful in this. In this thesis a stable cell line with overexpression of ERβ was established, different effects of ERα und ERβ were analyzed and the effects of mechanical strain on reporter gene constructs under controlled mechanosensitive response elements were characterized. KW - Östrogene KW - Mechanorezeptor KW - Osteoporose KW - Östrogenrezeptor KW - osteoporosis KW - Mechanotransduktion KW - mechanoresponsive Elemente KW - estrogen receptor KW - mechanotransduction KW - mechanoresponsive elements Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-222709 ER - TY - THES A1 - Streck, Laura Elisa T1 - Zweizeitige Implantation reverser Schulterendoprothesen bei Infektionen des Glenohumeralgelenks - Diagnostik und Ergebnisse - T1 - Staged reverse shoulder arthroplasty for the management of glenohumeral joint infections N2 - Infektionen des Schultergelenks gehen mit hoher Mortalität und Morbidität einher. Ihre Diagnostik und Therapie stellen häufig eine Herausforderung dar. Zudem ist - im Gegensatz zu Infektionen von Hüfte und Knie - die schulterspezifische Datenlage spärlich, es mangelt an evidenzbasierten Diagnose- und Therapiealgorithmen. Diese Arbeit evaluiert unter anderem 1) den Erfolg der mehrzeitigen Implantation reverser Schulterendoprothesen zur Therapie von Infektionen des Glenohumeralelenks, 2) das schulterspezifische Keimspektrum, 3) den Stellenwert einer präoperativen Gelenkpunktion und 3) den Stellenwert einer Gelenkspunktion bei einliegendem Spacer. Es handelt sich um eine retrospektive Studie mit prospektiver Datenerfassung an insgesamt 41 Patienten, welche zwischen 2007-2015 in der Orthopädischen Klinik König-Ludwig-Haus (Würzburg) die mehrzeitige Implantation einer Schulterendoprothese mit zwischenzeitlicher Implantation eines PMMA-Spacers auf Grund einer Infektion des Glenohumeralgelenks erhalten haben. Die vorliegende Arbeit konnte zeigen, dass Infektionen des Glenohumeralgelenks gehäuft multimorbide, voroperierte Patienten betreffen. Die Haupterreger waren Cutibakterien und koagulasenegative Staphylokokken, insbesondere S. epidermidis. Diese Erreger sollten bei einer kalkulierten Antibiotikatherapie immer berücksichtigt werden. Mikrobiologische Kulturen der präoperative Gelenkpunktion zeigten eine mäßige Sensitivität (58%) bei guter Spezifität (89%). Die Punktion kann somit keinen sicheren Infektionsausschluss bieten, ermöglicht im Falle eines Keimnachweises jedoch die gezielte antibiotische Therapie sowie die Anpassung der Antibiotika im Spacer und hat somit einen berechtigten Stellenwert in der Infektionsdiagnostik. Die Punktion bei einliegendem Spacer zeigte eine Sensitivität von 0%, ihre routinemäßige Durchführung sollte daher sehr kritisch hinterfragt werden. Für die Therapie mit mehrzeitiger Implantation einer reversen Schulterendoprothese zeigte sich eine Infektionseradikationsrate von 87% und ein kumulatives infektionsfreies Überleben von 91% nach 128 Monaten. Die Funktionalität der Schulter blieb hinter der Funktion der Gegenseite zurück, war jedoch ausreichend um die eigenständige Versorgung und die Durchführung von Alltagsaktivitäten zu ermöglichen. Die große Mehrzahl der Patienten hatte keine/minimale Schmerzen. N2 - Shoulder joint infections (SJI) come along with a high morbidity and mortality. Diagnosis and treatment of SJI can be challenging. In contrast to infections of the hip and knee, shoulder specific data is rare and no shoulder specific evidence based algorithms for diagnosis and treatment are available. This study investigated 1) the outcome of treatment with staged implantation of a reverse shoulder arthroplasty (RSA), 2) the shoulder specific bacterial spectrum, 3) the validity of a preoperative joint aspiration (PA) and 4) the validity of a joint aspiration while a spacer is implanted (interstage aspiration, IA). This work was a retrospective study with prospective data capturing on a total of 41 patients who were treated with staged implantation of a total shoulder arthroplasty with temporary implantation of a PMMA-Spacer for the management of glenohumeral joint infection between 2007-2015 at the Orthopedic department of the University of Wuerzburg (Koenig-Ludwig-Haus). This study showed that SJI mainly appear in multimorbid patients with several preliminary surgeries. Cutibacteria and coagulase negative staphylococci, especially S. epidermidis, were the predominant pathogens. Calculated antibiotic therapy should therefore always cover these pathogens. Microbiological cultures form PA showed a moderate sensitivity (58%) and a good specificity (89%). A negative culture cannot definitely rule out infection but in case of detection of bacteria, systemic antibiotic therapy as well as the antibiotics in the spacer can be adjusted specifically. PA therefore plays an important role in the diagnosis of SJI. IA showed a sensitivity of 0%. For this reason, IA as a part of the routine diagnostic procedure should be discussed very critically. Infection eradication after staged implantation of RSA was 87%, the cumulative infection-free survival rate was 91% after 128 months. Shoulder function was limited in most cases but yet sufficient to cope with activities of daily life properly. The vast majority of patients had no/minimal pain. KW - Endoprothese KW - Gelenkinfektion KW - Schultergelenk KW - Diagnostik KW - Therapieerfolg KW - Reverse Schulterendoprothese KW - Schultergelenksinfektion Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-222626 ER - TY - THES A1 - Roth, Magnus Ulrich Maria T1 - Die persistierende periprothetische Kniegelenkinfektion - Nutzen der Synovia-Analyse bei einliegendem Zement-Spacer T1 - Persistent Periprosthetic Joint Infection of the Knee - Value of Synovial Analysis with indwelling Spacer N2 - Der zweizeitige Endoprothesenwechsel gilt als Goldstandard der Therapie periprothetischer Gelenkinfektionen. Ein sicherer Ausschluss einer Infektpersistenz ist für den Therapieerfolg essentiel. Es wurde der diagnostische Nutzen synovialer Marker zum Ausschluss einer Infektpersistenz bei einliegendem Kniegelenksspacer untersucht. Weder mikrobiologische noch zytologische Synovia-Analysen sind zum Ausschluss einer Infektpersistenz im Rahmen des zweizeitigen Knieendoprothesenwechsels geeignet. N2 - Two-stage exchange is considered the gold-standard for therapy of infected joint-arthroplasty. To rule out infection persistence before reimplantation is essential for treatment success. Diagnostic value of synovial markers to rule out infection persistence were evaluated. Neither microbiological nor cytological tests could rule out infection persistence with indwelling pmma-spacer during two-stage-exchange of infected knee-arthroplasty. KW - Knie KW - knee KW - Spacer KW - zweizeitiger Prothesenwechsel KW - Synovia KW - Infektpersistenz KW - spacer KW - prosthesis-exchange KW - synovia KW - infection-persistence Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-220276 ER - TY - THES A1 - Swalve, Enno T1 - Wirksamkeit von niedrig dosierter Tranexamsäure bei Implantation von Knie - Endo - Prothesen T1 - Efficacy of Low Dose Tranexamic Acid in Implantation of Knee - Endo - Prostheses N2 - Eine retrospektive Studie anhand von Patientenunterlagen zum Blutverlust, Transfusionshäufigkeit und postoperativen Komplikationen bei Knie-Endo-Prothesen mit systemischer Gabe von 500 mg Tranexamsäure kurz vor Eröffnung der Blutleere! 229 Patienten in der Studiengruppe, von denen 9 eine erlaubte Wiederholungsdosis erhalten hatten, wurden verglichen mit 231 Patienten, die keine Tranexamsäure erhalten hatten. 3 Patienten der Studiengruppe gegenüber 14 Patienten der Kontrollgruppe benötigten eine Bluttransfusion. In der Studiengruppe war der niedrigste postoperative Hb bei 71,2% der Patienten 10 g/dl oder höher. In der Kontrollgruppe war es nur bei 49,4% der Patienten der Fall. Durch die Gabe von Tranexamsäure konnte der durchschnittliche, berechnete Blutverlust bei Männern von etwa 1850 ml auf 1450 ml und bei Frauen von etwa 1300 ml auf etwa 1000 ml gesenkt werden. Die Unterschiede waren signifikant! Im beobachteten Kollektiv konnte keine Steigerung der Rate an Thrombosen oder thrombembolischen Ereignissen festgestellt werden. Das Antifibrinolytikum Tranexamsäure ist in dieser niedrigen Dosierung effektiv und scheint sicher zu sein. N2 - A retrospective study based on patient blood loss, transfusion frequency and postoperative complications in knee endo prostheses with systemic administration of 500 mg Tranexamic Acid shortly before opening of the tourniquet! 229 patients in the study Group, 9 of them had received a permitted repeat dose, were compared to 231 patients who had not received Tranexamic Acid. 3 patients in the study group versus 14 patients in the control group needed a blood transfusion. The lowest postoperative Hb was 10 g/dl or higher in 71,2% of the patients in the study Group. Only 49,4% of the patients in the Control Group did so. The Administration of Tranexamic Acid reduced the average of calculated blood loss from about 1850 ml to 1450 ml in male und from about 1300 ml to about 1000 ml in female. The differences were significant No increase in the rate of thrombosis or thrombembolic Events could be observed in the collective. The antifibronolytic Tranexamic Acid is effective at this low dosage and seems to be safe. KW - Knieprothese KW - Tranexamsäure KW - Niedrig dosierte Tranexamsäure KW - Knie Endo Prothese KW - Low Dose Tranexamic acid KW - Knee Endo Prostheses Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217446 ER - TY - THES A1 - Mausolf, Nils Henrik T1 - Klinische und radiologische Ergebnisse nach Hüftprothesenwechsel durch Implantation eines kranial aufgesockelten Revisionspfannensystems T1 - Clinical and radiological outcome of acetabular cup revisions by using a cranial raised press-fit cup N2 - Background and issue: During the last years there was an increase of acetabular cup revisions. Furthermore the quality of life in elderly patients gains importance. Particularly challenging for orthopaedic surgeons is the treatment of extended acetabular defects. This study examines the clinical and radiological outcome of acetabular cup revisions by using a cranial raised press-fit cup. Additionally potential influencing factors were surveyed. Methods: In a retrospective monocentric study 155 patients, who underwent an acetabular cup revision by implanting an oval press-fit cup between 2009 and 2016 were reviewed and scored. An ethical clearance certificate of the University of Wuerzburg was given. Results: The mean follow-up was 53 months. 9 AAOS I defects, 25 AAOS II defects, 100 AAOS III defects and 21 AAOS IV defects were examined. The cumulative cup survival rate by using the Kaplan-Meier-Method was 93,4% (CI 89,1-97,6%). The survival rate without any revision was 84,0% (CI 77,9-90,1%). A significant reduction of pain on a numeric analogue scale could be proven (5,9 preoperative vs. 1,1 postoperative). The Harris-Hip Score increased significantly from 56,4 preoperative to 73,2 postoperative. In addition an improvement of all dimensions of the Euroqol could be confirmed. The overall state of health was measured by using the SF-12. As a result there was a slightly lower physical health and a slightly higher mental health compared to the reference population. Significant factors of influence on the outcome were detected: Male gender is associated with a higher functional outcome (HHS 87,7 vs. 74,2). Moreover, men numbered their level of pain lower than women did (NAS 0,65 vs. 1,5). Furthermore an association between more extended types of acetabular defects and a lower functional outcome could be confirmed. Additionally the factor age was found to create a significant influence on the functional outcome of the surgery. Patients below the age of 70 years upon the time of surgery reached higher results in Harris-Hip Score than older patients (82,2 vs. 77,3). Septic loosening was associated with a lower functional outcome than aseptic loosening (HHS 74,6 vs. 81,9). Conclusion: By analysing the survival rate, the improvement of function and the reduction of pain, good short- to midterm results were calculated for the surveyed implant system. Factors with a significant influence on the functional outcome were found to be: Gender, underlying type of defect, age upon surgery, septic or aseptic loosening. N2 - Fragestellung: Epidemiologisch zeigt sich seit einigen Jahren ein Anstieg der Fallzahlen von Hüftpannenrevisionen. Zudem gewinnt die Lebensqualität der älter werdenden Bevölkerung zunehmend an Bedeutung. Eine Herausforderung für den behandelnden Chirurgen stellt insbesondere die Versorgung von größeren acetabulären Defekten dar. In dieser Studie wurden klinische und radiologische Ergebnisse von Hüftpfannenrevisionen, die durch ein kranial aufgesockeltes, längsovales Revisionspfannensystem versorgt wurden, untersucht. Ferner sollten mögliche Einflussfaktoren auf das Operationsergebnis ermittelt werden. Methodik: In einer retrospektiven monozentrischen Studie wurden 155 Patienten, die im Zeitraum von 2009 bis 2016 mit Kranialpfannen versorgt wurden, nachuntersucht und Scores erhoben. Ein Unbedenklichkeitsbescheid der Ethikkommission der Universität Würzburg lag vor. Ergebnisse: Das Follow-up lag im Durchschnitt bei 53 Monaten. Es wurden 9 AAOS I Defekte, 25 AAOS II Defekte, 100 AAOS III Defekte und 21 AAOS IV-Defekte nachuntersucht. Das kumulative Gesamtüberleben nach Kaplan-Meier betrug für diesen Follow-up Zeitraum 93,4% (CI 89,1-97,6%). Das revisionsfreie Überleben lag bei 84,0% (CI 77,9-90,1%). Es konnte eine signifikante Schmerzreduktion auf einer visuellen Analogskala belegt werden (5,9 präoperativ vs. 1,1 postoperativ). Der Harris-Hip-Score verbesserte sich hochsignifikant von 56,4 präoperativ auf 73,2 postoperativ. Ferner konnte in allen Dimensionen des Euroqols eine signifikante Verbesserung nachgewiesen werden. Der Gesundheitszustand der Patienten wurde anhand des SF-12 bestimmt. Als Ergebnis zeigte sich verglichen mit der Referenzpopulation eine leicht erniedrigte physische Gesundheit und eine geringgradig erhöhte psychische Gesundheit. Im Rahmen dieser Arbeit konnten einige signifikante Einflussfaktoren auf das Operationsergebnis ermittelt werden: Das männliche Geschlecht ist mit einem signifikant besseren funktionellen Outcome assoziiert (HHS 87,7 vs. 74,2). Zudem gaben Männer auf der visuellen Analogskala eine signifikant geringere Schmerzintensität an (0,65 vs. 1,5). Darüber hinaus konnte belegt werden, dass höhergradige Defekttypen mit einem schlechteren funktionellen Outcome vergesellschaftet sind. Das funktionelle Outcome unterscheidet sich zudem signifikant in Abhängigkeit vom Alter der Patienten zum Zeitpunkt der Operation. Patienten unter 70 Jahren erreichten im Durchschnitt signifikant höhere Punktzahlen im Harris-Hip-Score (82,2 vs. 77,3). Septische Indikationen standen verglichen mit aseptischen Lockerungen ebenfalls in Assoziation mit einem schlechteren funktionellen Outcome (HHS 74,6 vs. 81,9). Schlussfolgerung: Anhand der im Zuge dieser Arbeit ermittelten Überlebensrate, einer Verbesserung der Funktionalität im Hüftgelenk und einer nachgewiesenen Schmerzreduktion konnten gute kurz- bis mittelfristige Ergebnisse für das vorliegende Implantatsystem gezeigt werden. Als Einflussfaktoren auf das klinische Outcome konnten das Geschlecht, der zugrunde liegende Defekttyp, das Alter zum OP-Zeitpunkt und eine septische oder aseptische Indikation ermittelt werden. KW - Hüftprothese KW - Hip KW - Revision KW - Acetabular KW - Press-fit KW - Hüfte KW - Hüftpfanne KW - Revision KW - Kranialpfanne Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217218 ER - TY - THES A1 - Hacker, Dorothee T1 - Prospektiv randomisierte Untersuchungen zum klinischen Outcome nach Knierevisionen mit den Endoprothesen „EnduRo“ im Vergleich zur Prothese „Endo-Modell“ T1 - Clinical Outcome of two rotating hinge prostheses designs in revision total knee arthroplasty – a prospective randomized study N2 - Aufgrund des demographischen Wandels mit einer zunehmend älter werdenden Bevölkerung ist die Zahl der Knieprothesen und vor allem auch der Revisionsoperationen in den letzten Jahren deutlich gestiegen. Mit ebenfalls zunehmendem medizinischem Anspruch wurden die bestehenden Prothesenmodelle stetig weiter entwickelt. Ziel der vorliegenden Studie war es, in einer prospektiv angelegten einfach verblindeten Studie zwei verschiedene Rotating-Hinge-Revisionsprothesen unterschiedlicher Hersteller miteinander zu vergleichen und sie auf ihr klinisches Outcome zu überprüfen. Von Juni 2012 bis Mai 2013 wurden insgesamt 25 Patienten in die Studie aufgenommen und dann bis zu 12 Monate nach erfolgter Revisionsoperation nachuntersucht. Die Zuteilung der Prothesenarten erfolgte randomisiert, sodass 13 Patienten die Prothese „EnduRo“ und 12 Patienten die Prothese „Endo-Modell“ erhielten. Als Vergleichswerte wurden klinische Scores herangezogen. In der Untersuchung zeigten beiden Vergleichsgruppen insgesamt eine deutliche Schmerzreduktion sowie eine Funktionsverbesserungen in allen erhobenen Scores. Zwar erreichten die Patienten der Gruppe „Endo-Modell“ etwas höhere Punktwerte, jedoch waren die Unterschiede im Vergleich zur Patientengruppe „EnduRo“ im durchgeführten Zweistichproben-T-Test nicht statistisch signifikant. N2 - The number of revision surgerys of the knee is increasing due to demographic change and higher life expectancy. Therefore the development and constant improvement of prosthesis design is essential. Aim of this study was to compare the clinical outcome of two rotating hinge prostheses (EnduRo and Endo-Model). Twentyfive patients with the indication for a total knee arthroplasty replacement because of ligament instability were prospectively randomised to either the Link Endo-Model (n = 12) or the EnduRo (n = 13). Clinical Scores (American Knee Society Score, Oxford Knee Score, Visual Analog Scale and SF-36) were evaluated pre-operatively and up to twelve months postoperatively. Although both prostheses models showed significant improvements as well in function scores as in pain reduction there was a slight advantage in favor of the Endo-Model. KW - Kniegelenk KW - Kniegelenkprothese KW - Vergleichsstudie KW - Total knee arthroplasty KW - Link Endo-Model KW - EnduRo KW - Knievrevision Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-215658 ER - TY - THES A1 - Braun, Clemens Michael T1 - Regenerative Kapazität Mesenchymaler Stammzellen bei aseptischer Prothesenlockerung T1 - Regenerative capacity of mesenchymal Stem cells in aseptic loosening N2 - Trotz ständiger Weiterentwicklung der modernen Endoprothetik weist ein künstliches Gelenk auch heute eine begrenzte Haltbarkeit auf. Insbesondere bei der Versorgung jüngerer Patienten mit gestiegener Lebenserwartung wird häufig die Prothesenstandzeit aufgebraucht und ein komplizierter Revisionseingriff notwendig. Hierbei ist die aseptische Prothesenlockerung der häufigste Grund für den Austausch eines Implantates. Das Knochenmark des betreffenden Knochens enthält humane Mesenchymale Stammzellen (hMSC), die zur Aufrechterhaltung und Regeneration des Bindegewebes und des Knochens selbst beitragen. Ob diese Zellen z.B. durch ein Proliferations- oder Differenzierungsdefizit eine Rolle in der Ätiologie einer aseptischen Prothesenlockerung spielen, ist bisher nicht abschließend geklärt. In der vorliegenden Arbeit wurde die regenerative Kapazität von hMSC von zwei Spendergruppen untersucht und verglichen: Als Wechselgruppe dienten Patienten, bei denen es zu einer aseptischen Prothesenlockerung und der Notwendigkeit eines Revisionseingriffes (Wechseloperation) gekommen war. Patienten, denen primär eine Hüft- oder Kniegelenksendoprothese eingesetzt wurde, bildeten die Kontrollgruppe. Zur Beurteilung der regenerativen Eigenschaften der hMSC wurde zum einen das Wachstums- und Alterungsverhalten in Zellkultur zum anderen die in vitro Differenzierungskapazität untersucht. N2 - Despite constant development of modern endoprosthetics, an artificial joint still has a limited life span. Especially when treating younger patients with an increased life expectancy, the prosthesis life span is often used up and a complicated revision procedure is necessary. Aseptic loosening of the prosthesis is the most common reason for replacing an implant. The bone marrow contains human mesenchymal stem cells (hMSC) that help maintain and regenerate the connective tissue and the bone itself. Whether these cells play a role in the etiology of aseptic loosening of the prosthesis through a proliferation or differentiation deficit has not yet been conclusively clarified. In the present study, the regenerative capacity of hMSC from two groups of donors was examined and compared: Patients who had undergone aseptic loosening of the prosthesis and who had to undergo revision surgery served as the experimental group. Patients who primarily received a hip or knee joint endoprosthesis formed the control group. To assess the regenerative properties of the hMSC, on the one hand the growth and aging behavior in cell culture and on the other hand the in vitro differentiation capacity was examined. KW - Aseptische Lockerung KW - Mesenchymzelle KW - Prothesenlockerung KW - Mesenchymale Stammzellen Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-213926 ER - TY - THES A1 - Dörries, Susanne T1 - Analyse der Gründe für Revisionsoperationen bei einliegender Knieprothese T1 - Analysis of the reasons for revision surgery with inserted knee arthroplasty N2 - Die Knieendoprothetik verzeichnet in den letzten Jahren steigende Zahlen, was wiederum steigende Zahlen an Revisionen zur Folge hat. Diese Studie hat die Gründe für Revisionen ermittelt. Hierzu wurden 1245 Operationen gesammelt und ausgewertet. Instabilität, Infektion und aseptische Lockerungen stellen die Hauptgründe für eine Revisionsoperation dar. Es wurden zusätzlich verschiedene Zeiträume zwischen Primärimplantation und Revision unterteilt und die jeweiligen Gründe ermittelt. N2 - Recent years have shown an increasing number of knee arthroplasty implantations with raising numbers of revisions as a result. This study has investigated into the reasons of revisions. For this purpose 1245 operations were collected and evaluated. Instability, periprosthetic infection and aseptic loosening are the main reasons for revision surgery. In addition, different time periods between primary implantation and revision were subdivided and the respective reasons were identified. KW - Reoperation KW - Knieprothese KW - knee arthroplasty KW - Revision KW - revision surgery Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-214034 ER - TY - THES A1 - Veith, Marina T1 - Langzeitergebnisse nach Versorgung proximaler Humerusfrakturen mittels intramedullärer Drahtosteosynthese nach Kapandji T1 - Outcome after Kapandji pinning of proximal humerus fractures N2 - In vorliegender Dissertation wurden die Langzeitergebnisse hinsichtlich der Lebensqualität der Patienten, die sich im Zeitraum 2002-2010 eine proximale Humerusfraktur zuzogen und mittels intramedullärer Drahtosteosynthese nach Kapandji im König Ludwig Haus in Würzburg operiert wurden, untersucht. Die Nachuntersuchung erfolgte mittels klinischer, radiologischer und sonografischer Untersuchung sowie durch Verwendung des DASH-Fragebogens, Constant Murley Score und der Visuellen Analogskala. N2 - The outcome of patients which got a proximal humerus fracture betweeen 2002-2010 and had been treated with Kapandji pinning in König Ludwig Haus in Würzburg has been investigated in this dissertation. The follow up examination includes clinical investigation, X-ray and ultrasonics as well as DASH form, Constant Murley Score and the visual analogue scale. KW - proximale Humerusfraktur KW - Kapandjidrahtosteosynthese KW - proximale Humerusfraktur KW - Kapandjidrahtosteosynthese KW - proximal humerus fracture KW - Kapandji pinning Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-209906 ER - TY - THES A1 - Glöckner, Frederik Paul Vincent T1 - Signalwege und Biomarker für die Adaptation mesenchymaler Gewebe an physikalische Kräfte T1 - Signaling pathways and biomarkers for the adaptation of mesenchymal tissues to mechanical forces N2 - Der menschliche Körper besitzt Anpassungsmechanismen, die es ihm ermöglichen, sich an verschiedene Belastungssituationen anzupassen. Es gab in letzter Zeit mehrere Hinweise darauf, dass diese Mechanismen durch die Ausschüttung von Zytokinen, bzw. Myokinen durch die betroffenen Zellen selbst ausgelöst werden. In dieser Arbeit wurden die Serumkonzentration von Myostatin, Follistatin, Follistatin-like-3, Interleukin 6, Interleukin 8 und Klotho vor und nach einer kurzen körperlichen Belastung bestimmt. Dabei konnte allerdings keine signifikante Änderung der Konzentrationen nachgewiesen werden, was die Frage aufwirft, ob mesenchymales Gewebe, insbesondere Muskelgewebe, überhaupt über einen klassischen endokrinen Sekretionsmechanismus verfügt. N2 - The human body is capable of adapting to different kinds of stress. There are some studies, that indicate, that different kind of mesenchymal tissues induces these adaptive mechanism by the secretion of cytokines and myokines. In this study we determine the serum concentration of myostatin, follistatin, follistatin-like-3, interleukine 6, interleukine 8 and klotho before and after a short, single bout of exercise. We couldn't find a signficant consistent changes of these biomarkers tough. That raises the question, if mesenchymal tissue, especially the muscle tissue, even have the ability of the classical endokrine secretion. KW - Fahrradergometer KW - Muskelgewebe KW - Anpassung KW - Zytokine KW - cytokines KW - Myokine KW - myokines Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-208918 ER - TY - THES A1 - Koschitzki, Kim Christine Cornelia T1 - Evaluation of preclinical animal models in bone tissue engineering and their success in clinical translation T1 - Evaluierung von vorklinischen Tiermodellen für Bone Tissue Engineering und von ihrem Erfolg in der klinischen Umsetzung N2 - Autologous bone still represents today’s gold standard for the treatment of critical size bone defects and fracture non-unions despite associated disadvantages regarding limitations in availability, donor site morbidity, costs and efficacy. Bone tissue engineered constructs would present a promising alternative to currently available treatments. However, research on preclinical animal studies still fails to provide clinical applicable results able to allow the replacement of currently applied methods. It seems that the idea of bone tissue engineering, which has now been integral part of academic studies for over 30 years, got somehow stuck at an intermediate level, in between intense preclinical research and striven stages of initial clinical trial phases. A clear discrepancy exists between the number of studies with preclinical animal models for bone tissue engineering and the number of clinically approved bone tissue engineered constructs available to patients. The aim of this thesis was hence to evaluate preclinical animal models for bone tissue engineering as well as the perception of scientists and clinicians towards these models. Moreover, the general role of bone tissue engineering and its clinical need assessed by scientists and surgeons was investigated. A survey was conducted questioning both scientific and clinical opinions on currently available study designs and researchers’ satisfaction with preclinical animal models. Additionally, a literature research was conducted, resulting in 167 papers from the last 10 years that report current designs of preclinical orthotopic animal studies in bone tissue engineering. Thereby, the focus lied on the description of the models regarding animal species, strain, age, gender and defect design. The outcome of the literature search was evaluated and compared to the outcome obtained from the survey. The survey data revealed that both scientists and surgeons generally remain positive about the future role of bone tissue engineering and its step to clinical translation, at least in the distant future, where it then might replace the current gold standard, autologous bone. Moreover, most of the participants considered preclinical animal models as relevant and well developed but the results as not yet realizable in the clinics. Surgeons thereby demonstrated a slightly more optimistic perception of currently conducted research with animal models compared to scientists. However, a rather inconsistent description of present preclinical study designs could be discerned when evaluating the reported study designs in the survey and the papers of the literature search. Indeed, defining an appropriate animal species, strain, age, gender, observation time, observation method and surgical design often depends on different indications and research questions and represents a highly challenging task for the establishment of a preclinical animal model. The existing lack of valid guidelines for preclinical testing of bone tissue engineering leads hence to a lack of well standardized preclinical animal models. Moreover, still existing knowledge gaps regarding aspects that affect the process of fracture healing, such as vascularization or immunological aspects, were found to hinder clinical translation of bone tissue engineered constructs. Using literature review and survey, this thesis points out critical issues that need to be addressed to allow clinical translation of bone tissue engineered constructs. It can be concluded that currently existing study designs with preclinical animal models cannot live up to the claim of providing suitable results for clinical implementation. The here presented comprehensive summary of currently used preclinical animal models for bone tissue engineering reveals a missing consensus on the usage of models such as an apparent lack of reporting and standardization regarding the study designs described in both papers from the literature review and the survey. It thereby indicates a crucial need to improve preclinical animal models in order to allow clinical translation. Despite the fact that participants of the survey generally revealed a positive perception towards the use of bone tissue engineered constructs and affirmed the clinical need for such novel designs, the missing standardization constitutes a main weak point for the provision of reliable study outcome and the translational success of the models. The optimization of reproducibility and reliability, as well as the further understanding of ongoing mechanisms in bone healing in order to develop effective tissue engineered constructs, need to form the basis of all study designs. The study outcomes might then fulfill the requirements of maybe today's and hopefully tomorrow's aging population. N2 - Über die letzten 30 Jahre hat die Rolle von Bone Tissue Engineering vielversprechenden Fortschritt gemacht und immer neue Ansätze werden etabliert. Somit stellt Bone Tissue Engineering eine aussichtsvolle Alternative zu dem heutigen Goldstandard (autogene Knochenersatzmaterialien) dar, nachdem diese häufig mit Nachteilen einhergehen: limitierte Verfügbarkeit, Morbidität durch Zweiteingriffe, ungenügend Stabilität und Kosten. Die klinische Umsetzung findet jedoch nicht so schnell statt, wie ursprünglich erhofft und es scheint, als würde die vorklinische Forschung auf der Stelle treten. Das Ausbleiben von reproduzierbaren und standardisierten vorklinischen Studien verhindert dabei eine "bench to bedside" Translation. Ziel dieser Doktorarbeit war es, derzeitige präklinische Tiermodelle für Bone Tissue Engineering zu evaluieren und dabei zu untersuchen, woran es liegen könnte, dass die Lücke zwischen vorklinischen Studienergebnissen und klinischer Umsetzung noch immer existiert. Es wurde ein Fragebogen erstellt, anhand dessen die generelle Meinung gegenüber Bone Tissue Engineering und die Effizienz derzeitiger präklinischer Studienmodelle aus sowohl klinischer, als auch wissenschaftlicher Sicht hinterfragt wurde. Hier wurde außerdem auf die Beurteilung der Zufriedenstellung solcher Modelle seitens der Forscher eingegangen. Darüber hinaus erfolgte eine systemische Literatursuche auf der Online-Plattform “Pubmed” mit dem Ziel Studien der letzten zehn Jahre über präklinische orthotopische Tiermodelle in Bone Tissue Engineering zusammenzufassen und die verschiedenen Studiendesigns zu evaluieren. Der Fokus lag dabei auf der Beschreibung der Tiermodelle bezüglich Tierart, Geschlecht, Alter und Defektdesign. Ergebnisse der Literatursuche wurden anschließend evaluiert und mit den Antworten aus dem Fragebogen verglichen und diskutiert. Es hat sich anhand des Fragebogens gezeigt, dass sowohl Wissenschaftler, als auch Chirurgen positiv gestimmt sind, was die zukünftige Anwendung von Bone Tissue Engineering in den Kliniken betrifft. Jedoch beurteilten die meisten Teilnehmer des Fragebogens die präklinischen Tiermodelle zwar als relevant und gut entwickelt, deren Ergebnisse als klinisch allerdings nicht anwendbar. Dabei fiel die Einschätzung präklinischer Forschung mit Tiermodellen unter den Chirurgen etwas optimistischer aus als unter den Forschern. Die Evaluierung der Studien aus dem Fragebogens und der Literatursuche zeigte jedoch auch, dass die darin beschriebenen Tiermodelle einen eher uneinheitlichen Studienaufbau aufweisen. Tatsächlich stellt die Etablierung eines fundierten Studiendesigns im Anbetracht der zahlreichen Möglichkeiten eine immense Herausforderung dar. Die Festlegung eines Versuchsaufbaus hängt dabei von der Wahl der Tierart, dessen Geschlecht und Alter, des chirurgischen Ablaufs, sowie der technischen und zeitlichen Beobachtungsmöglichkeit ab. Es stellte sich heraus, dass für viele Studien eine diesbezüglich notwendige Standardisierung kaum existiert und dadurch Studienergebnisse entstehen, die schwer reproduzierbar sind und somit den Ansprüchen einer klinischen Umsetzung nicht gerecht werden können. Hinzu kommen außerdem die noch immer bestehenden Wissenslücken in Bezug auf Knochenheilung beeinflussende Faktoren wie Vaskularisation und Abläufe des Immunsystems. Abschließend lässt sich sagen, dass die durchgeführte Evaluierung von Studien mit präklinischen Tiermodellen eine fehlende Standardisierung derzeit existierender Studiendesigns darlegt und eine klinische Umsetzung der daraus resultierenden Studienergebnissen somit noch nicht möglich ist. Auch wenn die Teilnehmer des Fragebogens den Bedarf an neuen, klinisch anerkannten Methoden für Knochenaufbauten nahelegten und eine generell positive Einstellung gegenüber dem potentiellen Gebrauch von Bone Tissue Engineering Konstrukte in den Kliniken zeigten, ist die Ablösung von autologem Knochen durch solch neuartige Designs nicht realisierbar, solange die Reproduzierbarkeit der Daten aus präklinischen Tiermodellstudien fehlt. Zusammen mit wegweisenden Richtlinien und fundiertem Wissen über grundliegende Mechanismen im Knochenheilungsprozess, sollte sie die Basis eines jeden Studienaufbaus mit präklinischen Tiermodellen darstellen, um schließlich zu den Ergebnissen zu gelangen, die es für eine klinische Umsetzung von Bone Tissue Engineering bedarf. KW - bone KW - tissue KW - engineering Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-207593 ER - TY - JOUR A1 - Dotterweich, Julia A1 - Schlegelmilch, Katrin A1 - Keller, Alexander A1 - Geyer, Beate A1 - Schneider, Doris A1 - Zeck, Sabine A1 - Tower, Robert J. J. A1 - Ebert, Regina A1 - Jakob, Franz A1 - Schütze, Norbert T1 - Contact of myeloma cells induces a characteristic transcriptome signature in skeletal precursor cells-implications for myeloma bone disease JF - Bone N2 - Physical interaction of skeletal precursors with multiple myeloma cells has been shown to suppress their osteogenic potential while favoring their tumor-promoting features. Although several transcriptome analyses of myeloma patient-derived mesenchymal stem cells have displayed differences compared to their healthy counterparts, these analyses insufficiently reflect the signatures mediated by tumor cell contact, vary due to different methodologies, and lack results in lineage-committed precursors. To determine tumor cell contact-mediated changes on skeletal precursors, we performed transcriptome analyses of mesenchymal stem cells and osteogenic precursor cells cultured in contact with the myeloma cell line INA-6. Comparative analyses confirmed dysregulation of genes which code for known disease-relevant factors and additionally revealed upregulation of genes that are associated with plasma cell homing, adhesion, osteoclastogenesis, and angiogenesis. Osteoclast-derived coupling factors, a dysregulated adipogenic potential, and an imbalance in favor of anti-anabolic factors may play a role in the hampered osteoblast differentiation potential of mesenchymal stem cells. Angiopoietin-Like 4 (ANGPTL4) was selected from a list of differentially expressed genes as a myeloma cell contact-dependent target in skeletal precursor cells which warranted further functional analyses. Adhesion assays with full-length ANGPTL4-coated plates revealed a potential role of this protein in INA6 cell attachment. This study expands knowledge of the myeloma cell contact-induced signature in the stromal compartment of myelomatous bones and thus offers potential targets that may allow detection and treatment of myeloma bone disease at an early stage. KW - marrow stromal cells KW - Endothelial growth-factor KW - precedes multiple-myeloma KW - monoclonial gammopathy KW - in-vitro KW - mesenchymal stem-cells KW - undetermined significance KW - angiogenic cytokines KW - peripheral-blood KW - gene-expression KW - Multiple myeloma KW - Bone disease KW - Angiopoietin-like 4 KW - Gene expression profiling KW - Mesenchymal stem cells KW - Osteogenic precursor cells Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-186688 VL - 93 ER -