TY - JOUR A1 - Linz, Christian A1 - Brands, Roman C. A1 - Kertels, Olivia A1 - Dierks, Alexander A1 - Brumberg, Joachim A1 - Gerhard-Hartmann, Elena A1 - Hartmann, Stefan A1 - Schirbel, Andreas A1 - Serfling, Sebastian A1 - Zhi, Yingjun A1 - Buck, Andreas K. A1 - Kübler, Alexander A1 - Hohm, Julian A1 - Lapa, Constantin A1 - Kircher, Malte T1 - Targeting fibroblast activation protein in newly diagnosed squamous cell carcinoma of the oral cavity – initial experience and comparison to [18F]FDG PET/CT and MRI JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose While [18F]-fluorodeoxyglucose ([18F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT. Methods Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [18F]FDG and [68Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUVmax) and peak (SUVpeak) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference. Results [18F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([18F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [18F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples. Conclusion FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted. KW - molecular imaging KW - fibroblast activation protein KW - head and neck cancer KW - PET Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-369331 VL - 48 ER - TY - JOUR A1 - Linz, Christian A1 - Brands, Roman C. A1 - Herterich, Theresia A1 - Hartmann, Stefan A1 - Müller-Richter, Urs A1 - Kübler, Alexander C. A1 - Haug, Lukas A1 - Kertels, Olivia A1 - Bley, Thorsten A. A1 - Dierks, Alexander A1 - Buck, Andreas K. A1 - Lapa, Constantin A1 - Brumberg, Joachim T1 - Accuracy of 18-F Fluorodeoxyglucose Positron Emission Tomographic/Computed Tomographic Imaging in Primary Staging of Squamous Cell Carcinoma of the Oral Cavity JF - JAMA Network Open N2 - Importance Squamous cell carcinoma (SCC) of the oral cavity is one of the most common tumor entities worldwide. Precise initial staging is necessary to determine a diagnosis, treatment, and prognosis. Objective To examine the diagnostic accuracy of preoperative 18-F fluorodeoxyglucose (FDG) positron emission tomographic/computed tomographic (PET/CT) imaging in detecting cervical lymph node metastases. Design, Setting, and Participants This prospective diagnostic study was performed at a single tertiary reference center between June 1, 2013, and January 31, 2016. Data were analyzed from April 7, 2018, through May 31, 2019. Observers of the FDG PET/CT imaging were blinded to patients’ tumor stage. A total of 150 treatment-naive patients with clinical suspicion of SCC of the oral cavity were enrolled. Exposures All patients underwent FDG PET/CT imaging before local tumor resection with selective or complete neck dissection. Main Outcomes and Measures The accuracy of FDG PET/CT in localizing primary tumor, lymph node, and distant metastases was tested. Histopathologic characteristics of the tissue samples served as the standard of reference. Results Of the 150 patients enrolled, 135 patients (74 [54.8%] men) with a median age of 63 years (range, 23-88 years) met the inclusion criteria (histopathologically confirmed primary SCC of the oral cavity/level-based histopathologic assessment of the resected lymph nodes). Thirty-six patients (26.7%) in the study cohort had neck metastases. Use of FDG PET/CT detected cervical lymph node metastasis with 83.3% sensitivity (95% CI, 71.2%-95.5%) and 84.8% specificity (95% CI, 77.8%-91.9%) and had a negative predictive value of 93.3% (95% CI, 88.2%-98.5%). The specificity was higher than for contrast-enhanced cervical CT imaging (67.0%; 95% CI, 57.4%-76.7%; P < .01) and cervical magnetic resonance imaging (62.6%; 95% CI, 52.7%-72.6%; P < .001). Ipsilateral lymph node metastasis in left- or right-sided primary tumor sites was detected with 78.6% sensitivity (95% CI, 63.4%-93.8%) and 83.1% specificity (95% CI, 75.1%-91.2%), and contralateral metastatic involvement was detected with 66.7% sensitivity (95% CI, 28.9%-100.0%) and 98.6% specificity (95% CI, 95.9%-100.0%). No distant metastases were observed. Conclusions and Relevance In this study, FDG PET/CT imaging had a high negative predictive value in detecting cervical lymph node metastasis in patients with newly diagnosed, treatment-naive SCC of the oral cavity. Routine clinical use of FDG PET/CT might lead to a substantial reduction of treatment-related morbidity in most patients. Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-369313 VL - 4 ER - TY - JOUR A1 - Lewis, Richard A1 - Habringer, Stefan A1 - Kircher, Malte A1 - Hefter, Maike A1 - Peuker, Caroline Anna A1 - Werner, Rudolf A1 - Ademaj-Kospiri, Valëza A1 - Gäble, Alexander A1 - Weber, Wolfgang A1 - Wester, Hans-Jürgen A1 - Buck, Andreas A1 - Herhaus, Peter A1 - Lapa, Constantin A1 - Keller, Ulrich T1 - Investigation of spleen CXCR4 expression by [68Ga]Pentixafor PET in a cohort of 145 solid cancer patients JF - EJNMMI Research N2 - Background The chemokine receptor CXCR4 is frequently overexpressed and associated with adverse prognosis in most hematopoietic malignancies and solid cancers. Recently, CXCR4 molecular imaging using the CXCR4-specific positron emission tomography (PET) tracer Pentixafor ([68Ga]Pentixafor) has become a well-established method to non-invasively measure CXCR4 expression in vivo. In previous Pentixafor imaging studies, highly variable CXCR4 tracer uptake to the spleen was observed. Results We investigated the hypothesis that enhanced spleen [68Ga]Pentixafor uptake and thus CXCR4 expression in patients with solid tumors would indicate an activated spleen state and/or an association with clinical and prognostic features and survival parameters. In this retrospective study, [68Ga]Pentixafor-PET images and patient records of 145 solid tumor patients representing 27 cancer entities were investigated for an association of spleen [68Ga]Pentixafor uptake and clinical characteristics and outcome. Based on this assessment, we did not observe differences in clinical outcomes, measured by progression-free survival, overall survival and remission status neither within the entire cohort nor within subgroups of adrenal cancer, desmoplastic small round cell tumor, neuroendocrine tumors, non-small cell lung cancer, small cell lung cancer and pancreatic adenocarcinoma patients. No tumor entity showed especially high levels of spleen [68Ga]Pentixafor uptake compared to others or a control cohort. However, when investigating laboratory parameters, there was a positive correlation of high spleen [68Ga]Pentixafor uptake with leukocyte and/or platelet counts in neuroendocrine tumors, non-small cell lung cancer and small cell lung cancer. Conclusion Spleen [68Ga]Pentixafor uptake was not associated with stage of disease and clinical outcomes in solid tumor patients. We identified positively associated platelet and/or leukocyte counts with spleen [68Ga]Pentixafor uptake in neuroendocrine tumors, non-small cell lung cancer and small cell lung cancer, suggesting that splenic CXCR4 expression could possibly play a role in systemic immunity/inflammation in some types of solid tumors or a subgroup of patients within solid tumor entities. KW - solid tumors KW - clinical studies KW - retrospective studies KW - molecular imaging KW - PET KW - CXCR4 KW - Pentixafor KW - spleen KW - uptake Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-363820 VL - 11 ER - TY - JOUR A1 - Linz, Christian A1 - Brands, Roman C. A1 - Kertels, Olivia A1 - Dierks, Alexander A1 - Brumberg, Joachim A1 - Gerhard-Hartmann, Elena A1 - Hartmann, Stefan A1 - Schirbel, Andreas A1 - Serfling, Sebastian A1 - Zhi, Yingjun A1 - Buck, Andreas K. A1 - Kübler, Alexander A1 - Hohm, Julian A1 - Lapa, Constantin A1 - Kircher, Malte T1 - Targeting fibroblast activation protein in newly diagnosed squamous cell carcinoma of the oral cavity – initial experience and comparison to [\(^{18}\)F]FDG PET/CT and MRI JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose While [\(^{18}\)F]-fluorodeoxyglucose ([\(^{18}\)F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT. Methods Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [\(^{18}\)F]FDG and [\(^{68}\)Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUV\(_{max}\)) and peak (SUV\(_{peak}\) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference. Results [\(^{18}\)F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([\(^{18}\)F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [\(^{18}\)F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples. Conclusion FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted. KW - molecular imaging KW - fibroblast activation protein KW - head and neck cancer KW - PET Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-307246 SN - 1619-7070 SN - 1619-7089 VL - 48 IS - 12 ER - TY - JOUR A1 - Weich, Alexander A1 - Higuchi, Takahiro A1 - Bundschuh, Ralph A. A1 - Lapa, Constantin A1 - Serfling, Sebastian E. A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Herrmann, Ken A1 - Buck, Andreas K. A1 - Derlin, Thorsten A1 - Werner, Rudolf A. T1 - Training on reporting and data system (RADS) for somatostatin-receptor targeted molecular imaging can reduce the test anxiety of inexperienced readers JF - Molecular Imaging and Biology N2 - Purpose For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader’s anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader’s confidence, and its implementation in clinical routine. Procedures A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader’s confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen’s d was calculated (small, d = 0.20; large effect, d = 0.80). Results Of 22 participants, Pre and Post were returned by 21/22 (95.5%). In total, 14/21 (66.7%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d =  − 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader’s confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21). Conclusions A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results. KW - PET/CT KW - neuroendocrine tumor KW - PRRT KW - peptide receptor radionuclide therapy KW - reporting and data system KW - SSTR-RADS KW - RADS Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324645 VL - 24 IS - 4 ER - TY - JOUR A1 - Brumberg, Joachim A1 - Blazhenets, Ganna A1 - Schröter, Nils A1 - Frings, Lars A1 - Jost, Wolfgang H. A1 - Lapa, Constantin A1 - Meyer, Philipp T. T1 - Imaging cardiac sympathetic innervation with MIBG: linear conversion of the heart-to-mediastinum ratio between different collimators JF - EJNMMI Physics N2 - Background The heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible. Methods We included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure. Results H/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R\(^2\) = 0.99, p < 0.001 and R\(^2\) = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 × H/M-ME + 0.63, R\(^2\) = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 ± 0.04; mean relative absolute error 3.2 ± 2.6%). Conclusions The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions. KW - MIBG KW - collimator KW - heart-to-mediastinum ratio KW - linear conversion Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-221675 VL - 6 ER - TY - JOUR A1 - Serfling, Sebastian E. A1 - Lapa, Constantin A1 - Dreher, Niklas A1 - Hartrampf, Philipp E. A1 - Rowe, Steven P. A1 - Higuchi, Takahiro A1 - Schirbel, Andreas A1 - Weich, Alexander A1 - Hahner, Stefanie A1 - Fassnacht, Martin A1 - Buck, Andreas K. A1 - Werner, Rudolf A. T1 - Impact of tumor burden on normal organ distribution in patients imaged with CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT JF - Molecular Imaging and Biology N2 - Background CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs. Methods Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden. Results Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found. Conclusions In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged. KW - CXCR4 KW - C-X-C motif chemokine receptor 4 KW - PET KW - [68Ga]PentixaFor KW - [177Lu]/[90Y]PentixaTher KW - theranostics KW - endoradiotherapy Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324622 VL - 24 IS - 4 ER - TY - JOUR A1 - Marquardt, André A1 - Hartrampf, Philipp A1 - Kollmannsberger, Philip A1 - Solimando, Antonio G. A1 - Meierjohann, Svenja A1 - Kübler, Hubert A1 - Bargou, Ralf A1 - Schilling, Bastian A1 - Serfling, Sebastian E. A1 - Buck, Andreas A1 - Werner, Rudolf A. A1 - Lapa, Constantin A1 - Krebs, Markus T1 - Predicting microenvironment in CXCR4- and FAP-positive solid tumors — a pan-cancer machine learning workflow for theranostic target structures JF - Cancers N2 - (1) Background: C-X-C Motif Chemokine Receptor 4 (CXCR4) and Fibroblast Activation Protein Alpha (FAP) are promising theranostic targets. However, it is unclear whether CXCR4 and FAP positivity mark distinct microenvironments, especially in solid tumors. (2) Methods: Using Random Forest (RF) analysis, we searched for entity-independent mRNA and microRNA signatures related to CXCR4 and FAP overexpression in our pan-cancer cohort from The Cancer Genome Atlas (TCGA) database — representing n = 9242 specimens from 29 tumor entities. CXCR4- and FAP-positive samples were assessed via StringDB cluster analysis, EnrichR, Metascape, and Gene Set Enrichment Analysis (GSEA). Findings were validated via correlation analyses in n = 1541 tumor samples. TIMER2.0 analyzed the association of CXCR4 / FAP expression and infiltration levels of immune-related cells. (3) Results: We identified entity-independent CXCR4 and FAP gene signatures representative for the majority of solid cancers. While CXCR4 positivity marked an immune-related microenvironment, FAP overexpression highlighted an angiogenesis-associated niche. TIMER2.0 analysis confirmed characteristic infiltration levels of CD8+ cells for CXCR4-positive tumors and endothelial cells for FAP-positive tumors. (4) Conclusions: CXCR4- and FAP-directed PET imaging could provide a non-invasive decision aid for entity-agnostic treatment of microenvironment in solid malignancies. Moreover, this machine learning workflow can easily be transferred towards other theranostic targets. KW - machine learning KW - tumor microenvironment KW - immune infiltration KW - angiogenesis KW - mRNA KW - miRNA KW - transcriptome Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-305036 SN - 2072-6694 VL - 15 IS - 2 ER - TY - JOUR A1 - Tutov, Anna A1 - Chen, Xinyu A1 - Werner, Rudolf A. A1 - Mühlig, Saskia A1 - Zimmermann, Thomas A1 - Nose, Naoko A1 - Koshino, Kazuhiro A1 - Lapa, Constantin A1 - Decker, Michael A1 - Higuchi, Takahiro T1 - Rationalizing the binding modes of PET radiotracers targeting the norepinephrine transporter JF - Pharmaceutics N2 - Purpose: A new PET radiotracer \(^{18}\)F-AF78 showing great potential for clinical application has been reported recently. It belongs to a new generation of phenethylguanidine-based norepinephrine transporter (NET)-targeting radiotracers. Although many efforts have been made to develop NET inhibitors as antidepressants, systemic investigations of the structure–activity relationships (SARs) of NET-targeting radiotracers have rarely been performed. Methods: Without changing the phenethylguanidine pharmacophore and 3-fluoropropyl moiety that is crucial for easy labeling, six new analogs of \(^{18}\)F-AF78 with different meta-substituents on the benzene-ring were synthesized and evaluated in a competitive cellular uptake assay and in in vivo animal experiments in rats. Computational modeling of these tracers was established to quantitatively rationalize the interaction between the radiotracers and NET. Results: Using non-radiolabeled reference compounds, a competitive cellular uptake assay showed a decrease in NET-transporting affinity from meta-fluorine to iodine (0.42 and 6.51 µM, respectively), with meta-OH being the least active (22.67 µM). Furthermore, in vivo animal studies with radioisotopes showed that heart-to-blood ratios agreed with the cellular experiments, with AF78(F) exhibiting the highest cardiac uptake. This result correlates positively with the electronegativity rather than the atomic radius of the meta-substituent. Computational modeling studies revealed a crucial influence of halogen substituents on the radiotracer–NET interaction, whereby a T-shaped π–π stacking interaction between the benzene-ring of the tracer and the amino acid residues surrounding the NET binding site made major contributions to the different affinities, in accordance with the pharmacological data. Conclusion: The SARs were characterized by in vitro and in vivo evaluation, and computational modeling quantitatively rationalized the interaction between radiotracers and the NET binding site. These findings pave the way for further evaluation in different species and underline the potential of AF78(F) for clinical application, e.g., cardiac innervation imaging or molecular imaging of neuroendocrine tumors. KW - positron emission tomography KW - norepinephrine transporter KW - sympathetic nervous system KW - structure–activity relationships KW - T-shaped π–π stacking Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-303949 SN - 1999-4923 VL - 15 IS - 2 ER - TY - JOUR A1 - Rasche, Leo A1 - Kumar, Manoj A1 - Gershner, Grant A1 - Samant, Rohan A1 - Van Hemert, Rudy A1 - Heidemeier, Anke A1 - Lapa, Constantin A1 - Bley, Thorsten A1 - Buck, Andreas A1 - McDonald, James A1 - Hillengass, Jens A1 - Epstein, Joshua A1 - Thanendrarajan, Sharmilan A1 - Schinke, Carolina A1 - van Rhee, Frits A1 - Zangari, Maurizio A1 - Barlogie, Bart A1 - Davies, Faith E. A1 - Morgan, Gareth J. A1 - Weinhold, Niels T1 - Lack of Spleen Signal on Diffusion Weighted MRI is associated with High Tumor Burden and Poor Prognosis in Multiple Myeloma: A Link to Extramedullary Hematopoiesis? JF - Theranostics N2 - Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM. KW - multiple myeloma KW - diffusion weighted mri KW - spleen KW - tumor burden KW - high risk KW - extramedullary hematopoiesis Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-224982 VL - 9 IS - 16 ER - TY - JOUR A1 - Zhou, Xiang A1 - Dierks, Alexander A1 - Kertels, Olivia A1 - Kircher, Malte A1 - Schirbel, Andreas A1 - Samnick, Samuel A1 - Buck, Andreas K. A1 - Knorz, Sebastian A1 - Böckle, David A1 - Scheller, Lukas A1 - Messerschmidt, Janin A1 - Barakat, Mohammad A1 - Kortüm, K. Martin A1 - Rasche, Leo A1 - Einsele, Hermann A1 - Lapa, Constantin T1 - 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor PET/CT in patients with smoldering multiple myeloma: imaging pattern and clinical features JF - Cancers N2 - This study aimed to explore the correlation between imaging patterns and clinical features in patients with smoldering multiple myeloma (SMM) who simultaneously underwent 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT). We retrieved and analyzed clinical characteristics and PET imaging data of 10 patients with SMM. We found a significant correlation between bone marrow (BM) plasma cell (PC) infiltration and mean standardized uptake values (SUV\(_{mean}\)) of lumbar vertebrae L2-L4 on 11C-Methionine PET/CT scans (r = 0.676, p = 0.031) and 68Ga-Pentixafor PET/CT scans (r = 0.839, p = 0.002). However, there was no significant correlation between BM involvement and SUV\(_{mean}\) of lumbar vertebrae L2-L4 on 18F-FDG PET/CT scans (r = 0.558, p = 0.093). Similarly, mean target-to-background ratios (TBR\(_{mean}\)) of lumbar vertebrae L2-L4 also correlated with bone marrow plasma cell (BMPC) infiltration in 11C-Methionine PET/CT (r = 0.789, p = 0.007) and 68Ga-Pentixafor PET/CT (r = 0.724, p = 0.018) PET/CT. In contrast, we did not observe a significant correlation between BMPC infiltration rate and TBR\(_{mean}\) in 18F-FDG PET/CT (r = 0.355, p = 0.313). Additionally, on 11C-Methionine PET/CT scans, we found a significant correlation between BMPC infiltration and TBR\(_{max}\) of lumbar vertebrae L2-L4 (r = 0.642, p = 0.045). In conclusion, 11C-Methionine and 68Ga-Pentixafor PET/CT demonstrate higher sensitivity than 18F-FDG PET/CT in detecting BM involvement in SMM. KW - 18F-FDG PET/CT KW - 11C-Methionine PET/CT KW - 68Ga-Pentixafor PET/CT KW - smoldering myeloma Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-211240 SN - 2072-6694 VL - 12 IS - 8 ER - TY - JOUR A1 - Werner, Rudolf A. A1 - Habacha, Bilêl A1 - Lütje, Susanne A1 - Bundschuh, Lena A1 - Higuchi, Takahiro A1 - Hartrampf, Philipp A1 - Serfling, Sebastian E. A1 - Derlin, Thorsten A1 - Lapa, Constantin A1 - Buck, Andreas K. A1 - Essler, Markus A1 - Pienta, Kenneth J. A1 - Eisenberger, Mario A. A1 - Markowski, Mark C. A1 - Shinehouse, Laura A1 - AbdAllah, Rehab A1 - Salavati, Ali A1 - Lodge, Martin A. A1 - Pomper, Martin G. A1 - Gorin, Michael A. A1 - Bundschuh, Ralph A. A1 - Rowe, Steven P. T1 - High SUVs Have More Robust Repeatability in Patients with Metastatic Prostate Cancer: Results from a Prospective Test-Retest Cohort Imaged with \(^{18}\)F-DCFPyL JF - Molecular Imaging N2 - No abstract available. KW - SUV Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300748 VL - 2022 ER - TY - JOUR A1 - Kosmala, Aleksander A1 - Serfling, Sebastian E. A1 - Dreher, Niklas A1 - Lindner, Thomas A1 - Schirbel, Andreas A1 - Lapa, Constantin A1 - Higuchi, Takahiro A1 - Buck, Andreas K. A1 - Weich, Alexander A1 - Werner, Rudolf A. T1 - Associations between normal organs and tumor burden in patients imaged with fibroblast activation protein inhibitor-directed positron emission tomography JF - Cancers N2 - (1) Background: We aimed to quantitatively investigate [\(^{68}\)Ga]Ga-FAPI-04 uptake in normal organs and to assess a relationship with the extent of FAPI-avid tumor burden. (2) Methods: In this single-center retrospective analysis, thirty-four patients with solid cancers underwent a total of 40 [\(^{68}\)Ga]Ga-FAPI-04 PET/CT scans. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were established by placing volumes of interest (VOIs) in the heart, liver, spleen, pancreas, kidneys, and bone marrow. Total tumor burden was determined by manual segmentation of tumor lesions with increased uptake. For tumor burden, quantitative assessment included maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA = TV × SUV\(_{mean}\)). Associations between uptake in normal organs and tumor burden were investigated by applying Spearman's rank correlation coefficient. (3) Results: Median SUV\(_{mean}\) values were 2.15 in the pancreas (range, 1.05–9.91), 1.42 in the right (range, 0.57–3.06) and 1.41 in the left kidney (range, 0.73–2.97), 1.2 in the heart (range, 0.46–2.59), 0.86 in the spleen (range, 0.55–1.58), 0.65 in the liver (range, 0.31–2.11), and 0.57 in the bone marrow (range, 0.26–0.94). We observed a trend towards significance for uptake in the myocardium and tumor-derived SUV\(_{max}\) (ρ = 0.29, p = 0.07) and TV (ρ = −0.30, p = 0.06). No significant correlation was achieved for any of the other organs: SUV\(_{max}\) (ρ ≤ 0.1, p ≥ 0.42), TV (ρ ≤ 0.11, p ≥ 0.43), and FTA (ρ ≤ 0.14, p ≥ 0.38). In a sub-analysis exclusively investigating patients with high tumor burden, significant correlations of myocardial uptake with tumor SUV\(_{max}\) (ρ = 0.44; p = 0.03) and tumor-derived FTA with liver uptake (ρ = 0.47; p = 0.02) were recorded. (4) Conclusions: In this proof-of-concept study, quantification of [\(^{68}\)Ga]Ga-FAPI-04 PET showed no significant correlation between normal organs and tumor burden, except for a trend in the myocardium. Those preliminary findings may trigger future studies to determine possible implications for treatment with radioactive FAP-targeted drugs, as higher tumor load or uptake may not lead to decreased doses in the majority of normal organs. KW - PET KW - [\(^{68}\)Ga]Ga-FAPI KW - theranostics KW - radioligand therapy KW - fibroblast activation protein Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-275154 SN - 2072-6694 VL - 14 IS - 11 ER - TY - JOUR A1 - Matsusaka, Yohji A1 - Werner, Rudolf A. A1 - Arias-Loza, Paula A1 - Nose, Naoko A1 - Sasaki, Takanori A1 - Chen, Xinyu A1 - Lapa, Constantin A1 - Higuchi, Takahiro T1 - Performance Evaluation of a Preclinical SPECT Scanner with a Collimator Designed for Medium-Sized Animals JF - Molecular Imaging N2 - Background. Equipped with two stationary detectors, a large bore collimator for medium-sized animals has been recently introduced for dedicated preclinical single-photon emission computed tomography (SPECT) imaging. We aimed to evaluate the basic performance of the system using phantoms and healthy rabbits. Methods. A general-purpose medium-sized animal (GP-MSA) collimator with 135 mm bore diameter and thirty-three holes of 2.5 mm diameter was installed on an ultrahigh-resolution scanner equipped with two large stationary detectors (U-SPECT5-E/CT). The sensitivity and uniformity were investigated using a point source and a cylinder phantom containing 99mTc-pertechnetate, respectively. Uniformity (in %) was derived using volumes of interest (VOIs) on images of the cylinder phantom and calculated as , with lower values of % indicating superior performance. The spatial resolution and contrast-to-noise ratios (CNRs) were evaluated with images of a hot-rod Derenzo phantom using different activity concentrations. Feasibility of in vivo SPECT imaging was finally confirmed by rabbit imaging with the most commonly used clinical myocardial perfusion SPECT agent [99mTc]Tc-sestamibi (dynamic acquisition with a scan time of 5 min). Results. In the performance evaluation, a sensitivity of 790 cps/MBq, a spatial resolution with the hot-rod phantom of 2.5 mm, and a uniformity of 39.2% were achieved. The CNRs of the rod size 2.5 mm were 1.37, 1.24, 1.20, and 0.85 for activity concentration of 29.2, 1.0, 0.5, and 0.1 MBq/mL, respectively. Dynamic SPECT imaging in rabbits allowed to visualize most of the thorax and to generate time-activity curves of the left myocardial wall and ventricular cavity. Conclusion. Preclinical U-SPECT5-E/CT equipped with a large bore collimator demonstrated adequate sensitivity and resolution for in vivo rabbit imaging. Along with its unique features of SPECT molecular functional imaging is a superior collimator technology that is applicable to medium-sized animal models and thus may promote translational research for diagnostic purposes and development of novel therapeutics. KW - SPECT Scanner KW - medium-sized animals KW - performance Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300713 VL - 2022 ER - TY - JOUR A1 - Matsusaka, Yohji A1 - Chen, Xinyu A1 - Arias-Loza, Paula A1 - Werner, Rudolf A. A1 - Nose, Naoko A1 - Sasaki, Takanori A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Lapa, Constantin A1 - Higuchi, Takahiro T1 - In Vivo Functional Assessment of Sodium-Glucose Cotransporters (SGLTs) Using [\(^{18}\)F]Me4FDG PET in Rats JF - Molecular Imaging N2 - Background. Mediating glucose absorption in the small intestine and renal clearance, sodium glucose cotransporters (SGLTs) have emerged as an attractive therapeutic target in diabetic patients. A substantial fraction of patients, however, only achieve inadequate glycemic control. Thus, we aimed to assess the potential of the SGLT-targeting PET radiotracer alpha-methyl-4-deoxy-4-[\(^{18}\)F]fluoro-D-glucopyranoside ([\(^{18}\)F]Me4FDG) as a noninvasive intestinal and renal biomarker of SGLT-mediated glucose transport. Methods. We investigated healthy rats using a dedicated small animal PET system. Dynamic imaging was conducted after administration of the reference radiotracer 2-deoxy-2-[\(^{18}\)F]fluoro-D-glucose ([\(^{18}\)F]FDG), or the SGLT-targeting agent, [\(^{18}\)F]Me4FDG either directly into the digestive tract (for assessing intestinal absorption) or via the tail vein (for evaluating kidney excretion). To confirm the specificity of [18F]Me4FDG and responsiveness to treatment, a subset of animals was also pretreated with the SGLT inhibitor phlorizin. In this regard, an intraintestinal route of administration was used to assess tracer absorption in the digestive tract, while for renal assessment, phlorizin was injected intravenously (IV). Results. Serving as reference, intestinal administration of [\(^{18}\)F]FDG led to slow absorption with retention of % of administered radioactivity at 15 min. [\(^{18}\)F]Me4FDG, however, was rapidly absorbed into the blood and cleared from the intestine within 15 min, leading to markedly lower tracer retention of % (). Intraintestinal phlorizin led to marked increase of [\(^{18}\)F]Me4FDG uptake (15 min, %; vs. untreated controls), supporting the notion that this PET agent can measure adequate SGLT inhibition in the digestive tract. In the kidneys, radiotracer was also sensitive to SGLT inhibition. After IV injection, [\(^{18}\)F]Me4FDG reabsorption in the renal cortex was significantly suppressed by phlorizin when compared to untreated animals (%ID/g at 60 min, vs. untreated controls, ; ). Conclusion. As a noninvasive read-out of the concurrent SGLT expression in both the digestive tract and the renal cortex, [\(^{18}\)F]Me4FDG PET may serve as a surrogate marker for treatment response to SGLT inhibition. As such, [\(^{18}\)F]Me4FDG may enable improvement in glycemic control in diabetes by PET-based monitoring strategies. KW - Sodium-Glucose Cotransporters (SGLTs) KW - diabetes KW - rats Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300708 VL - 2022 ER - TY - JOUR A1 - Chen, Xinyu A1 - Werner, Rudolf A. A1 - Koshino, Kazuhiro A1 - Nose, Naoko A1 - Mühlig, Saskia A1 - Rowe, Steven P. A1 - Pomper, Martin G. A1 - Lapa, Constantin A1 - Decker, Michael A1 - Higuchi, Takahiro T1 - Molecular Imaging-Derived Biomarker of Cardiac Nerve Integrity - Introducing High NET Affinity PET Probe \(^{18}\)F-AF78 JF - Theranostics N2 - Background: Radiolabeled agents that are substrates for the norepinephrine transporter (NET) can be used to quantify cardiac sympathetic nervous conditions and have been demonstrated to identify high-risk congestive heart failure (HF) patients prone to arrhythmic events. We aimed to fully characterize the kinetic profile of the novel \(^{18}\)F-labeled NET probe AF78 for PET imaging of the cardiac sympathetic nervous system (SNS) among various species. Methods: \(^{18}\)F-AF78 was compared to norepinephrine (NE) and established SNS radiotracers by employing in vitro cell assays, followed by an in vivo PET imaging approach with healthy rats, rabbits and nonhuman primates (NHPs). Additionally, chase protocols were performed in NHPs with NET inhibitor desipramine (DMI) and the NE releasing stimulator tyramine (TYR) to investigate retention kinetics in cardiac SNS. Results: Relative to other SNS radiotracers, 18F-AF78 showed higher transport affinity via NET in a cell-based competitive uptake assay (IC\(^{50}\) 0.42 ± 0.14 µM), almost identical to that of NE (IC\(^{50}\), 0.50 ± 0.16 µM, n.s.). In rabbits and NHPs, initial cardiac uptake was significantly reduced by NET inhibition. Furthermore, cardiac tracer retention was not affected by a DMI chase protocol but was markedly reduced by intermittent TYR chase, thereby suggesting that \(^{18}\)F-AF78 is stored and can be released via the synaptic vesicular turnover process. Computational modeling hypothesized the formation of a T-shaped π-π stacking at the binding site, suggesting a rationale for the high affinity of \(^{18}\)F-AF78. Conclusion: \(^{18}\)F-AF78 demonstrated high in vitro NET affinity and advantageous in vivo radiotracer kinetics across various species, indicating that \(^{18}\)F-AF78 is an SNS imaging agent with strong potential to guide specific interventions in cardiovascular medicine. KW - norepinephrine transporter KW - T-shaped π-π stacking KW - nonhuman primates KW - radiotracer kinetics KW - cardiac innervation imaging KW - sympathetic nervous system Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300685 VL - 12 IS - 9 SP - 4446 EP - 4458 ER - TY - JOUR A1 - Hänscheid, Heribert A1 - Hartrampf, Philipp E. A1 - Schirbel, Andreas A1 - Buck, Andreas K. A1 - Lapa, Constantin T1 - Intraindividual comparison of [\(^{177}\)Lu]Lu-DOTA-EB-TATE and [\(^{177}\)Lu]Lu-DOTA-TOC JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose The radiolabelled somatostatin analogue [\(^{177}\)Lu]Lu-DOTA-EB-TATE binds to albumin via Evans blue, thereby increasing the residence time in the blood and potentially allowing more therapeutic agent to be absorbed into the target tissue during peptide receptor radionuclide therapy. It was tested in selected patients whether the substance is superior to [\(^{177}\)Lu]Lu-DOTA-TOC. Methods Activity kinetics in organs and tumours after [\(^{177}\)Lu]Lu-DOTA-EB-TATE and [\(^{177}\)Lu]Lu-DOTA-TOC were compared intraindividually in five patients with progressive somatostatin receptor-positive disease scheduled for radionuclide therapy. Resuluts In comparison to [\(^{177}\)Lu]Lu-DOTA-TOC, tumour doses per administered activity were higher for [\(^{177}\)Lu]Lu-DOTA-EB-TATE in 4 of 5 patients (median ratio: 1.7; range: 0.9 to 3.9), kidney doses (median ratio: 3.2; range: 1.6 to 9.8) as well as spleen doses (median ratio: 4.7; range 1.2 to 6.2) in all patients, and liver doses in 3 of 4 evaluable patients (median ratio: 4.0; range: 0.7 to 4.9). The tumour to critical organs absorbed dose ratios were higher after [\(^{177}\)Lu]Lu-DOTA-TOC in 4 of 5 patients. Conclusions Prior to a treatment with [\(^{177}\)Lu]Lu-DOTA-EB-TATE, it should be assessed individually whether the compound is superior to established substances. KW - intraindividual comparison KW - DOTA-EB-TATE KW - somatostatin receptor KW - evans blue KW - biokinetics Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-265470 SN - 1619-7089 VL - 48 IS - 8 ER - TY - JOUR A1 - Morales-Lozano, Maria I. A1 - Viering, Oliver A1 - Samnick, Samuel A1 - Rodriguez-Otero, Paula A1 - Buck, Andreas K. A1 - Marcos-Jubilar, Maria A1 - Rasche, Leo A1 - Prieto, Elena A1 - Kortüm, K. Martin A1 - San-Miguel, Jesus A1 - Garcia-Velloso, Maria J. A1 - Lapa, Constantin T1 - \(^{18}\)F-FDG and \(^{11}\)C-methionine PET/CT in newly diagnosed multiple myeloma patients: comparison of volume-based PET biomarkers JF - Cancers N2 - \(^{11}\)C-methionine (\(^{11}\)C-MET) is a new positron emission tomography (PET) tracer for the assessment of disease activity in multiple myeloma (MM) patients, with preliminary data suggesting higher sensitivity and specificity than \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG). However, the value of tumor burden biomarkers has yet to be investigated. Our goals were to corroborate the superiority of \(^{11}\)C-MET for MM staging and to compare its suitability for the assessment of metabolic tumor burden biomarkers in comparison to \(^{18}\)F-FDG. Twenty-two patients with newly diagnosed, treatment-naïve symptomatic MM who had undergone \(^{11}\)C-MET and \(^{18}\)F-FDG PET/CT were evaluated. Standardized uptake values (SUV) were determined and compared with total metabolic tumor volume (TMTV) for both tracers: total lesion glycolysis (TLG) and total lesion \(^{11}\)C-MET uptake (TLMU). PET-derived values were compared to Revised International Staging System (R-ISS), cytogenetic, and serologic MM markers such as M component, beta 2 microglobulin (B2M), serum free light chains (FLC), albumin, and lactate dehydrogenase (LDH). In 11 patients (50%), \(^{11}\)C-MET detected more focal lesions (FL) than FDG (p < 0.01). SUVmax, SUVmean, SUVpeak, TMTV, and TLMU were also significantly higher in \(^{11}\)C-MET than in \(^{18}\)F-FDG (p < 0.05, respectively). \(^{11}\)C-MET PET biomarkers had a better correlation with tumor burden (bone marrow plasma cell infiltration, M component; p < 0.05 versus p = n.s. respectively). This pilot study suggests that \(^{11}\)C-MET PET/CT is a more sensitive marker for the assessment of myeloma tumor burden than \(^{18}\)F-FDG. Its implications for prognosis evaluation need further investigation. KW - multiple myeloma KW - methionine KW - total lesion glycolysis (TLG) KW - metabolic tumor volume (MTV) KW - total lesion methionine uptake (TLMU) Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-203686 SN - 2072-6694 VL - 12 IS - 4 ER - TY - JOUR A1 - Eissler, Cristoph A1 - Werner, Rudolf A. A1 - Arias-Loza, Paula A1 - Nose, Naoko A1 - Chen, Xinyu A1 - Pomper, Martin G. A1 - Rowe, Steven P. A1 - Lapa, Constantin A1 - Buck, Andreas K. A1 - Higuchi, Takahiro T1 - The number of frames on ECG-gated \(^{18}\)F-FDG small animal PET has a significant impact on LV systolic and diastolic functional parameters JF - Molecular Imaging N2 - Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. \(^{18}\)F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 & PLUSMN; 57.7 mu l*, 380.8 & PLUSMN; 57.2 mu l*, 398.0 & PLUSMN; 63.1 mu l*, and 444.8 & PLUSMN; 75.3 mu l at 4, 8, 12, and 16 frames, respectively; *P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed (P < 0.005), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used. KW - Myocardial-perfusion SPECT KW - left-ventricular function KW - ejection fraction KW - MRI Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-265778 VL - 2021 ER - TY - JOUR A1 - Nose, Naoko A1 - Nogami, Suguru A1 - Koshino, Kazuhiro A1 - Chen, Xinyu A1 - Werner, Rudolf A. A1 - Kashima, Soki A1 - Rowe, Steven P. A1 - Lapa, Constantin A1 - Fukuchi, Kazuki A1 - Higuchi, Takahiro T1 - [18F]FDG-labelled stem cell PET imaging in different route of administrations and multiple animal species JF - Scientific Reports N2 - Stem cell therapy holds great promise for tissue regeneration and cancer treatment, although its efficacy is still inconclusive and requires further understanding and optimization of the procedures. Non-invasive cell tracking can provide an important opportunity to monitor in vivo cell distribution in living subjects. Here, using a combination of positron emission tomography (PET) and in vitro 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) direct cell labelling, the feasibility of engrafted stem cell monitoring was tested in multiple animal species. Human mesenchymal stem cells (MSCs) were incubated with phosphate-buffered saline containing [18F]FDG for in vitro cell radiolabelling. The pre-labelled MSCs were administrated via peripheral vein in a mouse (n=1), rats (n=4), rabbits (n=4) and non-human primates (n=3), via carotid artery in rats (n=4) and non-human primates (n=3), and via intra-myocardial injection in rats (n=5). PET imaging was started 10 min after cell administration using a dedicated small animal PET system for a mouse and rats. A clinical PET system was used for the imaging of rabbits and non-human primates. After MSC administration via peripheral vein, PET imaging revealed intense radiotracer signal from the lung in all tested animal species including mouse, rat, rabbit, and non-human primate, suggesting administrated MSCs were trapped in the lung tissue. Furthermore, the distribution of the PET signal significantly differed based on the route of cell administration. Administration via carotid artery showed the highest activity in the head, and intra-myocardial injection increased signal from the heart. In vitro [18F]FDG MSC pre-labelling for PET imaging is feasible and allows non-invasive visualization of initial cell distribution after different routes of cell administration in multiple animal models. Those results highlight the potential use of that imaging approach for the understanding and optimization of stem cell therapy in translational research. KW - biomarkers KW - molecular medicine KW - stem-cell research KW - stem cells Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260590 VL - 11 IS - 1 ER -