TY - JOUR A1 - Grunz, Jan-Peter A1 - Sailer, Lukas A1 - Lang, Patricia A1 - Schüle, Simone A1 - Kunz, Andreas Steven A1 - Beer, Meinrad A1 - Hackenbroch, Carsten T1 - Dual-energy CT in sacral fragility fractures: defining a cut-off Hounsfield unit value for the presence of traumatic bone marrow edema in patients with osteoporosis JF - BMC Musculoskeletal Disorders N2 - Background Demographic change entails an increasing incidence of fragility fractures. Dual-energy CT (DECT) with virtual non-calcium (VNCa) reconstructions has been introduced as a promising diagnostic method for evaluating bone microarchitecture and marrow simultaneously. This study aims to define the most accurate cut-off value in Hounsfield units (HU) for discriminating the presence and absence of bone marrow edema (BME) in sacral fragility fractures. Methods Forty-six patients (40 women, 6 men; 79.7 ± 9.2 years) with suspected fragility fractures of the sacrum underwent both DECT (90 kVp / 150 kVp with tin prefiltration) and MRI. Nine regions-of-interest were placed in each sacrum on DECT-VNCa images. The resulting 414 HU measurements were stratified into “edema” (n = 80) and “no edema” groups (n = 334) based on reference BME detection in T2-weighted MRI sequences. Area under the receiver operating characteristic curve was calculated to determine the desired cut-off value and an associated conspicuity range for edema detection. Results The mean density within the “edema” group of measurements (+ 3.1 ± 8.3 HU) was substantially higher compared to the “no edema” group (-51.7 ± 21.8 HU; p < 0.010). Analysis in DECT-VNCa images suggested a cut-off value of -12.9 HU that enabled sensitivity and specificity of 100% for BME detection compared to MRI. A range of HU values between -14.0 and + 20.0 is considered indicative of BME in the sacrum. Conclusions Quantitative analysis of DECT-VNCa with a cut-off of -12.9 HU allows for excellent diagnostic accuracy in the assessment of sacral fragility fractures with associated BME. A diagnostic “one-stop-shop” approach without additional MRI is feasible. KW - virtual noncalcium imaging KW - dual-energy computed tomography KW - fragility fracture KW - bone bruise KW - bone marrow edema Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301125 VL - 23 IS - 1 ER - TY - JOUR A1 - Grunz, Jan-Peter A1 - Pennig, Lenhard A1 - Fieber, Tabea A1 - Gietzen, Carsten Herbert A1 - Heidenreich, Julius Frederik A1 - Huflage, Henner A1 - Gruschwitz, Philipp A1 - Kuhl, Philipp Josef A1 - Petritsch, Bernhard A1 - Kosmala, Aleksander A1 - Bley, Thorsten Alexander A1 - Gassenmaier, Tobias T1 - Twin robotic x-ray system in small bone and joint trauma: Impact of cone-beam computed tomography on treatment decisions JF - European Radiology N2 - Objectives Trauma evaluation of extremities can be challenging in conventional radiography. A multi-use x-ray system with cone-beam CT (CBCT) option facilitates ancillary 3-D imaging without repositioning. We assessed the clinical value of CBCT scans by analyzing the influence of additional findings on therapy. Methods Ninety-two patients underwent radiography and subsequent CBCT imaging with the twin robotic scanner (76 wrist/hand/finger and 16 ankle/foot/toe trauma scans). Reports by on-call radiologists before and after CBCT were compared regarding fracture detection, joint affliction, comminuted injuries, and diagnostic confidence. An orthopedic surgeon recommended therapy based on reported findings. Surgical reports (N = 52) and clinical follow-up (N = 85) were used as reference standard. Results CBCT detected more fractures (83/64 of 85), joint involvements (69/53 of 71), and multi-fragment situations (68/50 of 70) than radiography (all p < 0.001). Six fractures suspected in radiographs were ruled out by CBCT. Treatment changes based on additional information from CBCT were recommended in 29 patients (31.5%). While agreement between advised therapy before CBCT and actual treatment was moderate (κ = 0.41 [95% confidence interval 0.35–0.47]; p < 0.001), agreement after CBCT was almost perfect (κ = 0.88 [0.83–0.93]; p < 0.001). Diagnostic confidence increased considerably for CBCT studies (p < 0.001). Median effective dose for CBCT was 4.3 μSv [3.3–5.3 μSv] compared to 0.2 μSv [0.1–0.2 μSv] for radiography. Conclusions CBCT provides advantages for the evaluation of acute small bone and joint trauma by detecting and excluding extremity fractures and fracture-related findings more reliably than radiographs. Additional findings induced therapy change in one third of patients, suggesting substantial clinical impact. KW - cone-beamcomputed tomography KW - extremities KW - fractures, bone KW - radiography Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235233 SN - 0938-7994 VL - 31 ER - TY - JOUR A1 - Grunz, Jan-Peter A1 - Kunz, Andreas Steven A1 - Baumann, Freerk T. A1 - Hasenclever, Dirk A1 - Sieren, Malte Maria A1 - Heldmann, Stefan A1 - Bley, Thorsten Alexander A1 - Einsele, Hermann A1 - Knop, Stefan A1 - Jundt, Franziska T1 - Assessing osteolytic lesion size on sequential CT scans is a reliable study endpoint for bone remineralization in newly diagnosed multiple myeloma JF - Cancers N2 - Multiple myeloma (MM) frequently induces persisting osteolytic manifestations despite hematologic treatment response. This study aimed to establish a biometrically valid study endpoint for bone remineralization through quantitative and qualitative analyses in sequential CT scans. Twenty patients (seven women, 58 ± 8 years) with newly diagnosed MM received standardized induction therapy comprising the anti-SLAMF7 antibody elotuzumab, carfilzomib, lenalidomide, and dexamethasone (E-KRd). All patients underwent whole-body low-dose CT scans before and after six cycles of E-KRd. Two radiologists independently recorded osteolytic lesion sizes, as well as the presence of cortical destruction, pathologic fractures, rim and trabecular sclerosis. Bland–Altman analyses and Krippendorff’s α were employed to assess inter-reader reliability, which was high for lesion size measurement (standard error 1.2 mm) and all qualitative criteria assessed (α ≥ 0.74). After six cycles of E-KRd induction, osteolytic lesion size decreased by 22% (p < 0.001). While lesion size response did not correlate with the initial lesion size at baseline imaging (Pearson’s r = 0.144), logistic regression analysis revealed that the majority of responding osteolyses exhibited trabecular sclerosis (p < 0.001). The sum of osteolytic lesion sizes on sequential CT scans defines a reliable study endpoint to characterize bone remineralization. Patient level response is strongly associated with the presence of trabecular sclerosis. KW - multiple myeloma KW - bone remineralization KW - computed tomography KW - whole-body imaging Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-362526 SN - 2072-6694 VL - 15 IS - 15 ER - TY - JOUR A1 - Grunz, Jan-Peter A1 - Gietzen, Carsten Herbert A1 - Luetkens, Karsten A1 - Wagner, Matthias A1 - Kalb, Karlheinz A1 - Bley, Thorsten Alexander A1 - Lehmkul, Luka A1 - van Schoonhoven, Jörg A1 - Gassenmaier, Tobias A1 - Schmitt, Rainer T1 - The importance of radial multiplanar reconstructions for assessment of triangular fibrocartilage complex injury in CT arthrography of the wrist JF - BMC Musculoskeletal Disorders N2 - Background: Triangular fibrocartilage complex (TFCC) lesions commonly cause ulnar-sided wrist pain and instability of the distal radioulnar joint. Due to its triangular shape, discontinuity of the TFCC is oftentimes difficult to visualize in radiological standard planes. Radial multiplanar reconstructions (MPR) may have the potential to simplify diagnosis in CT wrist arthrography. The objective of this study was to assess diagnostic advantages provided by radial MPR over standard planes for TFCC lesions in CT arthrography. Methods: One hundred six patients (49 women, 57 men; mean age 44.2 ± 15.8 years) underwent CT imaging after wrist arthrography. Two radiologists (R1, R2) retrospectively analyzed three randomized datasets for each CT arthrography. One set contained axial, coronal and sagittal planes (MPR\(_{Standard}\)), while the other two included an additional radial reconstruction with the rotating center either atop the ulnar styloid (MPR\(_{Styloid}\)) or in the ulnar fovea (MPR\(_{Fovea}\)). Readers evaluated TFCC differentiability and condition. Suspected lesions were categorized using Palmer’s and Atzei’s classification and diagnostic confidence was stated on a fivepoint Likert scale. Results: Compared to standard planes, differentiability of the superficial and deep TFCC layer was superior in radial reconstructions (R1/R2; MPR\(_{Fovea}\): p < 0.001; MPRStyloid: p ≤ 0.007). Palmer and Atzei lesions were present in 86.8% (92/106) and 52.8% (56/106) of patients, respectively. Specificity, sensitivity and accuracy for central Palmer lesions did not differ in radial and standard MPR. For peripheral Atzei lesions, sensitivity (MPR\(_{Standard}\) 78.6%/80.4%, MPR\(_{Styloid}\) 94.6%/94.6%, MPR\(_{Fovea}\) 91.1%/89.3%) and accuracy (MPR\(_{Standard}\) 86.8%/86.8%, MPR\(_{Styloid}\) 96.2%/96.2%, MPR\(_{Fovea}\) 94.3%/93.4%) improved with additional styloid-centered (p = 0.004/0.008) and foveacentered (p = 0.039/0.125) reconstructions. No substantial difference was observed between both radial MPR (p = 0.688/0.250). Interrater agreement was almost perfect for each dataset (κ\(_{Standard}\) = 0.876, κ\(_{Styloid}\) = 0.894, κ\(_{Fovea}\) = 0.949). Diagnostic confidence increased with addition of either radial MPR (p < 0.001). Conclusions: Ancillary radial planes improve accuracy and diagnostic confidence for detection of peripheral TFCC lesions in CT arthrography of the wrist. KW - Triangular fibrocartilage KW - Wrist KW - Arthrography KW - Tomography KW - X-ray computed Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-236075 VL - 21 ER - TY - JOUR A1 - Grebe, Sören Jendrik A1 - Malzahn, Uwe A1 - Donhauser, Julian A1 - Liu, Dan A1 - Wanner, Christoph A1 - Krane, Vera A1 - Hammer, Fabian T1 - Quantification of left ventricular mass by echocardiography compared to cardiac magnet resonance imaging in hemodialysis patients JF - Cardiovascular Ultrasound N2 - Background: Left ventricular hypertrophy (LVH), defined by the left ventricular mass index (LVMI), is highly prevalent in hemodialysis patients and a strong independent predictor of cardiovascular events. Compared to cardiac magnetic resonance imaging (CMR), echocardiography tends to overestimate the LVMI. Here, we evaluate the diagnostic performance of transthoracic echocardiography (TTE) compared to CMR regarding the assessment of LVMI in hemodialysis patients. Methods: TTR and CMR data for 95 hemodialysis patients who participated in the MiREnDa trial were analyzed. The LVMI was calculated by two-dimensional (2D) TTE-guided M-mode measurements employing the American Society of Echocardiography (ASE) and Teichholz (Th) formulas, which were compared to the reference method, CMR. Results: LVH was present in 44% of patients based on LVMI measured by CMR. LVMI measured by echocardiography correlated moderately with CMR, ASE: r = 0.44 (0.34-0.62); Th: r = 0.44 (0.32-0.62). Compared to CMR, both echocardiographic formulas overestimated LVMI (mean increment LVMI (ASE-CMR): 19.5 +/- 19.48 g/m(2),p < 0.001; mean increment LVMI (Th-CMR): 15.9 +/- 15.89 g/m(2),p < 0.001). We found greater LVMI overestimation in patients with LVH using the ASE formula compared to the Th formula. Stratification of patients into CMR LVMI quartiles showed a continuous decrease in increment LVMI with increasing CMR LVMI quartiles for the Th formula (p < 0.001) but not for the ASE formula (p = 0.772). Bland-Altman analysis showed that the Th formula had a constant bias independent of LVMI. Both methods had good discrimination ability for the detection of LVH (ROC-AUC: 0.819 (0.737-0.901) and 0.808 (0.723-0.892) for Th and ASE, respectively). Conclusions: The ASE and Th formulas overestimate LVMI in hemodialysis patients. However, the overestimation is less with the Th formula, particularly with increasing LVMI. The results suggest that the Th formula should be preferred for measurement of LVMI in chronic hemodialysis patients. KW - Teichholz formula KW - ASE formula KW - echocardiography KW - left ventricular hypertrophy KW - left ventricular mass index KW - hemodialysis Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229282 VL - 18 ER - TY - THES A1 - Grathwohl, Daniela T1 - Quantitative Sonoelastographie der Leber bei Kindern und Jugedlichen mit Cystischer Fibrose T1 - Quantitative ultrasound imaging of the liver in children and adolescents with cystic fibrosis N2 - Morbidität und Mortalität der Lebererkrankung im Rahmen der Cystischen Fiborse (Cystic fibrosis liver disease, CFLD) sind vornehmlich von Ausmaß und Progredienz der Leberfibrose abhängig. Aufgrund der fehlenden Genauigkeit der bisherigen diagnostischen Verfahren werden viele der an CF erkrankten Menschen erst in fortgeschrittenen Stadien diagnostiziert. Schwere Komplikationen einer Leberzirrhose treten häufig bereits im Kindesalter auf. Die Quantitative Sonoelastographie, hier die Acoustic Radiation Force Impulse (ARFI)-Elastographie, ist ein vielversprechendes, nicht-invasives und strahlenfreies Verfahren zur Messung der Gewebesteifigkeit. Anhand dieser retrospektiven, monozentrischen Studie soll die ARFI-Elastographie im Hinblick auf den klinischen Einsatz bei der CFLD-Diagnostik untersucht werden. Es wurde eruiert, ob sich mittels ARFI-Elastographie Rückschlüsse auf eine CFLD und deren Schweregrade ziehen lassen. Hierfür wurden die ARFI-Messungen verschiedener Lebersegmente von 62 an CF erkrankten und 19 lebergesunden Kindern und Jugendlichen verglichen. Zudem erfolgte die Korrelation der Ergebnisse mit zwei etablierten klinischen Leberfibrose-Scores (APRI, Williams-Score). Im Patientenkollektiv konnten tendenziell erhöhte Scherwellengeschwindigkeiten, entsprechend einer fibrotischen Aktivität, gemessen werden. Die transkostale Messposition in Segment VII/VIII (TC VII/VIII) erwies sich als zuverlässigste Position zur Differenzierung zwischen einer CF-Hepatopathie und einem gesunden Leberparenchym. Hingegen war das Errechnen von Cut-off Werten zur Graduierung von Fibrosestadien nicht möglich. Auch war keine Korrelation zu Leberfiborsescores feststellbar. Insgesamt zeigt sich, dass die Diagnosestellung einer CFLD aktuell nur in Kombination mit bisherigen Messmethoden wie der klinischen Untersuchung, der Laboranalytik und der Sonographie möglich ist. Die Interpretation der ARFI-cut-off Werte bleibt aufgrund mangelnder Sensitivität und Spezifität und vor dem Hintergrund der CF-typischen heterogenen Leberpathologie erschwert. Die ARFI-Elastographie kann als zusätzlicher Baustein in der Diagnostik der CFLD, bei unklaren Befundkonstellationen oder zum Therapie-Monitoring herangezogen werden. Um einen klaren klinischen Einsatz in der Routinediagnostik zu definieren bedarf es weiterer großer, multizentrischer und prospektiver Studien. N2 - The liver-associated morbidity and mortality of the patients with cystic fibrosis (CF) depends on the progression of liver fibrosis. The lack of sensitive diagnostics in the early stages of fibrosis is a key reason for delayed diagnosis, often when complications from liver cirrhosis have already developed in childhood. Quantitative ultrasound (US) imaging, such as Acoustic Radiation Force Imaging (ARFI)-Elastography, is a modern and non-invasive technique for the measurement of tissue stiffness. ARFI-Elastography could improve the detection of Liver Disease (LD) in CF over today‘s routine diagnostics. The aim of this single centre, retrospective study was to analyse the diagnostic performance and the clinical use of the ARFI-method with regard to the early detection of parenchymal changes in Cystic Fibrosis Liver Disease (CFLD). ARFI-data of 62 patients with CF were compared to 19 healthy controls. Results have been related to common and previously established scores (APRI, Williams-Score) for fibrosis in CF. ARFI measurements were higher in the patient group. In particular, the transcostal imaging of segments VII/VIII (TC CII/VIII) of the right liver lobe showed a statistically significant difference between patients with CF and healthy controls. However, because of the wide range of the measurements it was not possible to establish cutoff-values to differentiate stages of liver stiffness and there was no correlation to clinical scores of fibrosis. Due to the lack of sensitivity and specificity of the ARFI cutoff-value and the knowledge of the heterogeneous pathology of cirrhosis in CF, interpretation of ARFI measurements remains challenging. On the basis of our findings, we conclude that ARFI may have a useful role in combination with routine assessments including physical examination, screening laboratory values and US-imaging, to detect, diagnose and monitor CFLD. Larger prospective validation studies are required to establish how ARFI can best be incorporated into routine clinical practice. KW - Ultraschall-Elastographie KW - Cystische Fibrose KW - Quantitative Sonoelastographie KW - Acoustic radiation force imaging (ARFI) KW - Leberfibrose KW - Cystic fibrosis liver disease (CFLD) Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-250621 ER - TY - JOUR A1 - Gilbert, Fabian A1 - Klein, Detlef A1 - Weng, Andreas Max A1 - Köstler, Herbert A1 - Schmitz, Benedikt A1 - Schmalzl, Jonas A1 - Böhm, Dirk T1 - Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration JF - BMC Muscoskeletal Disorders N2 - Background: Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly. Methods: Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test. Results: Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle. Conclusion: These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS. KW - shoulder surgery KW - rotator cuff KW - MRI KW - ultrasound KW - fatty degeneration Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159378 VL - 18 IS - 549 ER - TY - JOUR A1 - Gilbert, Fabian A1 - Böhm, Dirk A1 - Eden, Lars A1 - Schmalzl, Jonas A1 - Meffert, Rainer H. A1 - Köstler, Herbert A1 - Weng, Andreas M. A1 - Ziegler, Dirk T1 - Comparing the MRI-based Goutallier Classification to an experimental quantitative MR spectroscopic fat measurement of the supraspinatus muscle JF - BMC Musculoskeletal Disorders N2 - Background The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy. Methods MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman’s rank correlation. Results Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01). Conclusion The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting. KW - rotator cuff KW - MRI KW - spectroscopy KW - goutallier KW - classification KW - shoulder surgery Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-147788 VL - 17 IS - 355 ER - TY - JOUR A1 - Gilbert, F. A1 - Schneemann, C. A1 - Scholz, C. J. A1 - Kickuth, R. A1 - Meffert, R. H. A1 - Wildenauer, R. A1 - Lorenz, U. A1 - Kellersmann, R. A1 - Busch, A. T1 - Clinical implications of fracture-associated vascular damage in extremity and pelvic trauma JF - BMC Muscuskeletal Disorders N2 - Background: Vascular damage in polytrauma patients is associated with high mortality and morbidity. Therefore, specific clinical implications of vascular damage with fractures in major trauma patients are reassessed. Methods: This comprehensive nine-year retrospective single center cohort study analyzed demography, laboratory, treatment and outcome data from 3689 patients, 64 patients with fracture-associated vascular injuries were identified and were compared to a control group. Results: Vascular damage occurred in 7% of patients with upper and lower limb and pelvic fractures admitted to the trauma room. Overall survival was 80% in pelvic fracture and 97% in extremity fracture patients and comparable to non-vascular trauma patients. Additional arterial damage required substantial fluid administration and was visible as significantly anemia and disturbed coagulation tests upon admission. Open procedures were done in over 80% of peripheral extremity vascular damage. Endovascular procedures were predominant (87%) in pelvic injury. Conclusion: Vascular damage is associated with high mortality rates especially in combination with pelvic fractures. Initial anemia, disturbed coagulation tests and the need for extensive pre-clinical fluid substitution were observed in the cohort with vascular damage. Therefore, fast diagnosis and early interventional and surgical procedures are necessary to optimize patient-specific outcome. KW - endovascular repair KW - extremity trauma KW - fracture-associated vascular damage KW - level of evidence: IV KW - surgical trauma room KW - pelvic trauma Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176252 VL - 19 IS - 404 ER - TY - JOUR A1 - Gilbert, F. A1 - Meffert, R. H. A1 - Schmalzl, J. A1 - Weng, A. M. A1 - Köstler, H. A1 - Eden, L. T1 - Grade of retraction and tendon thickness correlates with MR-spectroscopically measured amount of fatty degeneration in full thickness supraspinatus tears JF - BMC Musculoskeletal Disorders N2 - Background: The amount of fatty degeneration (FD) has major impact on the clinical result and cuff integrity after rotator cuff repair. A quantitative analysis with magnet resonance imaging (MRI) spectroscopy was employed to analyze possible correlation of FD with tendon retraction, tendon thickness and patients’ characteristics in full thickness supraspinatus tears. Methods: Forty-two patients with full-thickness supraspinatus tears underwent shoulder MRI including an experimental spectroscopic sequence allowing quantification of the fat fraction in the supraspinatus muscle belly. The amount of fatty degeneration was correlated with tendon retraction, tendon thickness, patients’ age, gender, smoker status, symptom duration and body mass index (BMI). Patients were divided in to three groups of retraction (A) 0-10 mm (n=), (B) 11-20 mm (n=) and (C) < 21 mm (n=) and the means of FD for each group were calculated. Results: Tendon retraction (R = 0.6) and symptom duration (R = 0.6) correlated positively, whereas tendon thickness correlated negatively (R = − 0.6) with the amount of FD. The fat fraction increased significantly with tendon retraction: Group (A) showed a mean fat mount of 3.7% (±4%), group (B) of 16.7% (±8.2%) and group (C) of 37.5% (±19%). BMI, age and smoker-status only showed weak to moderate correlation with the amount of FD in this cohort. Conclusion: MRI spectroscopy revealed significantly higher amount of fat with increasing grade of retraction, symptom duration and decreased tendon thickness. Thus, these parameters may indirectly be associated with the severity of tendon disease. KW - rotator cuff KW - MRI KW - spectroscopy KW - muscle degeneration Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176116 VL - 19 IS - 197 ER - TY - JOUR A1 - Gilbert, F. A1 - Heintel, T. M. A1 - Jakubietz, M. G. A1 - Köstler, H. A1 - Sebald, C. A1 - Meffert, R. H. A1 - Weng, A. M. T1 - Quantitative MRI comparison of multifidus muscle degeneration in thoracolumbar fractures treated with open and minimally invasive approach JF - BMC Musculoskeletal Disorders N2 - Background: Minimally invasive pedicle screw fixation has less approach-related morbidity than open screw placement and is allegedly less traumatizing on paravertebral muscles, as there is no requirement to mobilize and retract the adjacent muscle portion. The approach-related long-term effects to the morphology of the paravertebral muscles are unknown. The purpose of this study was to compare the long-term amount of fatty degeneration of the multifidus muscle in patients treated with a classical open or a minimally invasive approach. Methods: Fourteen Patients meeting inclusion criteria were selected. In all patients a singular fracture of the thoracolumbar spine with a two-level posterior instrumentation was treated, either using an open approach or a minimally invasive approach. All patients underwent quantitative MRI spectroscopy for quantification of the fatty degeneration in the multifidus muscle as a long-term proof for muscle loss after minimum 4-year follow-up. Clinical outcome was assessed using Oswestry Low Back Pain Disability Questionnaire, SF-36 and VA-scale for pain. Results: The minimally invasive approach group failed to show less muscle degeneration in comparison to the open group. Total amount of fatty degeneration was 14.22% in the MIS group and 12.60% in the open group (p = 0.64). In accordance to MRI quantitative results there was no difference in the clinical outcome after a mean follow up of 5.9 years (±1.8). Conclusion: As short-term advantages of minimal invasive screw placement have been widely demonstrated, no advantage of the MIS, displaying a significant difference in the amount of fatty degeneration and resulting in a better clinical outcome could be found. Besides the well-known short-term advantage of minimally invasive pedicle screw placement, a long-term advantage, such as less muscle degeneration and thus superior clinical results, compared to the open approach could not be shown. KW - dorsal instrumentation KW - minimal invasive surgery KW - muscle degeneration KW - spine trauma Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-175742 VL - 19 IS - 75 ER - TY - JOUR A1 - Gietzen, Carsten Herbert A1 - Kunz, Andreas Steven A1 - Luetkens, Karsten Sebastian A1 - Huflage, Henner A1 - Christopoulos, Georgios A1 - van Schoonhoven, Jörg A1 - Bley, Thorsten Alexander A1 - Schmitt, Rainer A1 - Grunz, Jan-Peter T1 - Evaluation of prestyloid recess morphology and ulnar-sided contrast leakage in CT arthrography of the wrist JF - BMC Musculoskeletal Disorders N2 - Background In wrist arthrograms, aberrant contrast material is frequently seen extending into the soft tissue adjacent to the ulnar styloid process. Since the prestyloid recess can mimic contrast leakage in CT arthrography, this study aims to provide a detailed analysis of its morphologic variability, while investigating whether actual ulnar-sided leakage is associated with injuries of the triangular fibrocartilage complex (TFCC). Methods Eighty-six patients with positive wrist trauma history underwent multi-compartment CT arthrography (40 women, median age 44.5 years). Studies were reviewed by two board-certified radiologists, who documented the morphology of the prestyloid recess regarding size, opening type, shape and position, as well as the presence or absence of ulnar-sided contrast leakage. Correlations between leakage and the presence of TFCC injuries were assessed using the mean square contingency coefficient (r\(_{ɸ}\)). Results The most common configuration of the prestyloid recess included a narrow opening (73.26%; width 2.26 ± 1.43 mm), saccular shape (66.28%), and palmar position compared to the styloid process (55.81%). Its mean length and anterior–posterior diameter were 6.89 ± 2.36 and 5.05 ± 1.97 mm, respectively. Ulnar-sided contrast leakage was reported in 29 patients (33.72%) with a mean extent of 12.30 ± 5.31 mm. Leakage occurred more often in patients with ulnar-sided TFCC injuries (r\(_{ɸ}\) = 0.480; p < 0.001), whereas no association was found for lesions of the central articular disc (r\(_{ɸ}\) = 0.172; p = 0.111). Conclusions Since ulnar-sided contrast leakage is more common in patients with peripheral TFCC injuries, distinction between an atypical configuration of the prestyloid recess and actual leakage is important in CT arthrography of the wrist. KW - prestyloid recess KW - arthrography KW - tomography KW - x-ray computed KW - triangular fibrocartilage complex Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301113 VL - 23 IS - 1 ER - TY - JOUR A1 - Gerhard-Hartmann, Elena A1 - Wiegering, Verena A1 - Benoit, Clemens A1 - Meyer, Thomas A1 - Rosenwald, Andreas A1 - Maurus, Katja A1 - Ernestus, Karen T1 - A large retroperitoneal lipoblastoma as an incidental finding: a case report JF - BMC Pediatrics N2 - Background Lipoblastoma is a rare benign mesenchymal neoplasm of infancy that most commonly occurs on the extremities and trunk but can arise at variable sites of the body. Retroperitoneal lipoblastomas are particularly rare but can grow to enormous size, and preoperative diagnosis is difficult with diverse, mostly malignant differential diagnoses that would lead to aggressive therapy. Since lipoblastoma is a benign tumor that has an excellent prognosis after resection, correct diagnosis is crucial. Case presentation A case of a large retroperitoneal tumor of a 24-month old infant that was clinically suspicious of a malignant tumor is presented. Due to proximity to the right kidney, clinically most probably a nephroblastoma or clear cell sarcoma of the kidney was suspected. Radiological findings were ambiguous. Therefore, the mass was biopsied, and histology revealed an adipocytic lesion. Although mostly composed of mature adipocytes, in view of the age of the patient, the differential diagnosis of a (maturing) lipoblastoma was raised, which was supported by molecular analysis demonstrating a HAS2-PLAG1 fusion. The tumor was completely resected, and further histopathological workup led to the final diagnosis of a 13 cm large retroperitoneal maturing lipoblastoma. The child recovered promptly from surgery and showed no evidence of recurrence so far. Conclusion Although rare, lipoblastoma should be included in the differential diagnoses of retroperitoneal tumors in infants and children, and molecular diagnostic approaches could be a helpful diagnostic adjunct in challenging cases. KW - retroperitoneal tumor KW - pediatric KW - lipoblastoma KW - PLAG1 rearrangement KW - case report Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260173 VL - 21 ER - TY - THES A1 - Gemeinhardt, Katharina Christine T1 - Magnetresonanztomographie und -spektroskopie der Schulter nach Latissimus-dorsi-Transfer unter Berücksichtigung von Sehnenintegrität, Atrophie und fettiger Degeneration der Rotatorenmanschette T1 - Magnetic resonance tomography and spectroscopy of the shoulder N2 - Darstellung des Latissimus-dorsi-Transfers mit Hilfe des MRTs. Quantifizierung der fettigen Degeneration mit Hilfe der semiquantitativen Methode nach Goutailler und der 2D-SPLASH-Sequenz. N2 - Magnetic resonance tomography and spectroscopy of the shoulder, fatty degeneration and atrophy after rotator cuff tear KW - NMR-Tomographie KW - Breiter Rückenmuskel KW - Rotatorenmanschette KW - Atrophie KW - Fett KW - 2D-SPLASH KW - Spektroskopie KW - 2D-SPLASH Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-28035 ER - TY - JOUR A1 - Geiger, Julia A1 - Hirtler, Daniel A1 - Gottfried, Kristina A1 - Rahman, Ozair A1 - Bollache, Emilie A1 - Barker, Alex J. A1 - Markl, Michael A1 - Stiller, Brigitte T1 - Longitudinal Evaluation of Aortic Hemodynamics in Marfan Syndrome: New Insights from a 4D Flow Cardiovascular Magnetic Resonance Multi-Year Follow-Up Study JF - Journal of Cardiovascular Magnetic Resonance N2 - Background The aim of this 4D flow cardiovascular magnetic resonance (CMR) follow-up study was to investigate longitudinal changes in aortic hemodynamics in adolescent patients with Marfan syndrome (MFS). Methods 4D flow CMR for the assessment of in-vivo 3D blood flow with full coverage of the thoracic aorta was performed twice (baseline scan t1/follow-up scan t2) in 19 adolescent MFS patients (age at t1: 12.7 ± 3.6 years, t2: 16.2 ± 4.3 years) with a mean follow-up duration of 3.5 ± 1.2 years. Ten healthy volunteers (24 ± 3.8 years) served as a control group. Data analysis included aortic blood flow visualization by color-coded 3D pathlines, and grading of flow patterns (helices/vortices) on a 3-point scale (none, moderate, severe; blinded reading, 2 observers). Regional aortic peak systolic velocities and systolic 3D wall shear stress (WSS) along the entire aortic wall were quantified. Z-Scores of the aortic root and proximal descending aorta (DAo) were assessed. Results Regional systolic WSS was stable over the follow-up duration, except for a significant decrease in the proximal inner DAo segment (p = 0.02) between t1 and t2. MFS patients revealed significant lower mean systolic WSS in the proximal inner DAo compared with volunteers (0.78 ± 0.15 N/m\(^{2}\)) at baseline t1 (0.60 ± 0.18 N/m\(^{2}\); p = 0.01) and follow-up t2 (0.55 ± 0.16 N/m\(^{2}\); p = 0.001). There were significant relationships (p < 0.01) between the segmental WSS in the proximal inner DAo, DAo Z-scores (r = −0.64) and helix/vortex pattern grading (r = −0.55) at both t1 and t2. The interobserver agreement for secondary flow patterns assessment was excellent (Cohen’s k = 0.71). Conclusions MFS patients have lower segmental WSS in the inner proximal DAo segment which correlates with increased localized aberrant vortex/helix flow patterns and an enlarged diameter at one of the most critical sites for aortic dissection. General aortic hemodynamics are stable but these subtle localized DAo changes are already present at young age and tend to be more pronounced in the course of time. KW - Marfan syndrome KW - wall shear stress KW - hemodynamics KW - 4D flow cardiovascular magnetic resonance KW - follow-up KW - aorta Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-171119 VL - 19 IS - 33 ER - TY - JOUR A1 - Gassenmaier, Tobias A1 - Petritsch, Bernhard A1 - Kunz, Andreas S. A1 - Gkaniatsas, Spyridon A1 - Gaudron, Philipp D. A1 - Weidemann, Frank A1 - Nordbeck, Peter A1 - Beer, Meinrad T1 - Long term evolution of MRI characteristics in a case of atypical left lateral wall hypertrophic cardiomyopathy JF - World Journal of Cardiology N2 - We are reporting a long-time magnetic resonance imaging (MRI) follow-up in a rare case of cardiac left lateral wall hypertrophy. Hypertrophic cardiomyopathy (HCM) is the most common genetic cardiovascular disorder and a significant cause of sudden cardiac death. Cardiac magnetic resonance (CMR) imaging can be a valuable tool for assessment of detailed information on size, localization, and tissue characteristics of hypertrophied myocardium. However, there is still little knowledge of long-term evolution of HCM as visualized by magnetic resonance imaging. Recently, our group reported a case of left lateral wall HCM as a rare variant of the more common forms, such as septal HCM, or apical HCM. As we now retrieved an old cardiac MRI acquired in this patient more than 20 years ago, we are able to provide the thrilling experience of an ultra-long MRI follow-up presentation in this rare case of left lateral wall hypertrophy. Furthermore, this case outlines the tremendous improvements in imaging quality within the last two decades of CMR imaging. KW - cardiac magnetic resonance imaging KW - hypertrophic cardiomyopathy KW - follow-up KW - atypical KW - left lateral wall Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124934 VL - 7 IS - 6 ER - TY - JOUR A1 - Gassenmaier, Tobias A1 - Gorski, Armin A1 - Aleksic, Ivan A1 - Deubner, Nikolas A1 - Weidemann, Frank A1 - Beer, Meinrad T1 - Impact of cardiac magnet resonance imaging on management of ventricular septal rupture after acute myocardial infarction JF - World Journal of Cardiology N2 - A 74-year-old man was admitted to the cardiac catheterization laboratory with acute myocardial infarction. After successful angioplasty and stent implantation into the right coronary artery, he developed cardiogenic shock the following day. Echocardiography showed ventricular septal rupture. Cardiac magnet resonance imaging (MRI) was performed on the critically ill patient and provided detailed information on size and localization of the ruptured septum by the use of fast MRI sequences. Moreover, the MRI revealed that the ventricular septal rupture was within the myocardial infarction area, which was substantially larger than the rupture. As the patient’s condition worsened, he was intubated and had intra-aortic balloon pump implanted, and extracorporeal membrane oxygenation was initiated. During the following days, the patient’s situation improved, and surgical correction of the ventricular septal defect could successfully be performed. To the best of our knowledge, this case report is the first description of postinfarction ventricular septal rupture by the use of cardiac MRI in an intensive care patient with cardiogenic shock and subsequent successful surgical repair. KW - Cardiac magnetic resonance imaging KW - Ventricular septal rupture KW - Myocardial infarction KW - surgical repair KW - Extracorporeal membrane oxygenation Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-96562 ER - TY - THES A1 - Gasparyan, Artur T1 - Quantifizierung pulmonaler Blutflussgeschwindigkeit durch SENCEFUL Magnetresonanztomographie mit bewegter Schichtselektion T1 - Quantification of pulmonary blood flow velocity through SENCEFUL magnetic resonance imaging using moving slice selection N2 - Patienten mit chronischen Lungenerkrankungen leiden unter schwerwiegender Symptomatik und bedürfen regelmäßiger Verlaufskontrollen der Therapie. Dabei sollte zum Schutz der Patienten sowohl auf kanzerogene, ionisierende Strahlung verzichtet als auch der Einsatz potenziell nebenwirkungsreicher Kontrastmittel vermieden werden. Die pulmonale Blutflussgeschwindigkeit im Parenchym stellt einen quantitativen, bildgebenden Biomarker dar, mit dessen Hilfe die Dynamik des Krankheitsgeschehens untersucht werden kann. In dieser Arbeit wurde eine neue Auswertungsmethode vorgestellt, die mit Hilfe kontrastmittelfreier Magnetresonanztomographie die Blutflussgeschwindigkeit im Lungenparenchym quantifizieren kann. Die auf diese Weise bestimmten Ergebnisse entsprechen den Angaben zur Lungenperfusion, wie sie in der Literatur zu finden sind. N2 - Patients with chronic respiratory diseases suffer from severe symptoms and require regular follow ups during treatment. It is important to avoid the use of cancerogenic ionising radiation as well as potentially harmful contrast agents. The pulmonary blood flow velocity within the parenchyma can serve as a quantitative imaging biomarker, which can help analyse the course of the disease. In this work a new method for the quantification of pulmonary blood flow velocity is shown. The results correspond to physiological values in the human lung. KW - Kernspintomografie KW - Lunge KW - Blutflussgeschwindigkeit KW - Quantitativ Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-215693 ER - TY - THES A1 - Fuchs, Kilian T1 - Absolutquantifizierung der myokardialen Perfusion mit hochauflösender MRT bei 3 Tesla T1 - Absolute Quantification of Myocardial Perfusion Using High-Resolution MRI at 3 T N2 - In den letzten Jahren hat die myokardiale MR-Perfusionsbildgebung als nichtinvasives Verfahren zur Darstellung von funktionellen Veränderungen des Myokards für die Diagnostik der KHK zunehmend an Bedeutung gewonnen. Während in den letzten 20 Jahren die kardiale MRT überwiegend bei einer Magnetfeldstärke von 1,5 T durchge-führt wurde und dies auch immer noch wird, findet aktuell eine rasante Verbreitung von MR-Systemen höherer Feldstärken statt. Von der neuen Hochfeldtechnik erhofft man sich vor allem, je nach Anwendung, eine deutliche Verbesserung der Bildqualität mit höherer räumlicher und zeitlicher Auflösung, wodurch der diagnostische Nutzen noch weiter gesteigert werden könnte. In der vorliegenden Arbeit wurden mittels First-Pass-MR-Bildgebung bei einer Magnet-feldstärke von 3 T quantitative Werte für die myokardiale Perfusion von 20 gesunden Probanden unter Ruhebedingungen bestimmt. Sowohl die erhobenen absoluten Perfusionswerte (0,859 ml/g/min im Mittel) als auch die Standardabweichung des mittleren MBF (0,298 ml/g/min) entsprechen den Messungen aus den früheren Publikationen dieser Arbeitsgruppe. In der Gesamtzusammenschau bisher veröffentlichter Perfusionsstudien zeigt sich eine relativ große Variabilität der publizierten Ruheflüsse. Dabei liegt der absolute MBF dieser Arbeit im mittleren Wertebereich dieser Streubreite. Er lässt sich auch mit den in PET-Studien ermittelten Ergebnissen in Einklang bringen, welche als Goldstandard zur Bestimmung der absoluten myokardialen Perfusion beim Menschen gelten. Die vorliegende Arbeit bestätigt die bereits in anderen 3 T-Studien untersuchten Vorteile der Hochfeld-MRT. Die höhere Magnetfeldstärke ermöglicht durch das größere SNR eine signifikant bessere räumliche Auflösung und besticht vor allem durch die hohe Bildqualität. Dies könnte bei der Erkennung kleiner, subendokardial gelegener Perfusionsdefekte sowie der Erstellung von transmuralen Perfusionsgradienten von Bedeutung sein und verspricht neben einer Reduktion von Partialvolumeneffekten auch eine Verminderung von „dark rim“-Artefakten. Um diese Vorteile entsprechend nutzen zu können, wird die Entwicklung von Methoden zur pixelweisen Bestimmung der absoluten Flüsse und farblich kodierten Darstellung derselben in Form von Perfusionskarten ein weiterer Schritt in Richtung klinisch einsetzbare Diagnostik sein. Eine Voraussetzung hierfür ist die Entwicklung einer exakten und sehr stabilen Bewegungskorrektur in weiterführenden Studien. Durch den Wechsel zu einer höheren Magnetfeldstärke von 3 T und den sich daraus ergebenden Vorteilen kann das Potential der MR-Perfusionsbildgebung, insbesondere der Bestimmung quantitativer Perfusionswerte, im Bereich der nichtinvasiven KHK-Diagnostik zukünftig weiter gesteigert werden. N2 - Absolute Quantification of Myocardial Perfusion Using High-Resolution MRI at 3 T KW - Kernspintomographie KW - Perfusion KW - Feldstärke KW - Quantifizierung KW - Absolutquantifizierung KW - myokardiale Perfusion KW - 3 Tesla KW - Hochfeld KW - Magnetresonanztomographie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-107015 ER - TY - THES A1 - Fuchs, Jan Christopher T1 - Quantitative MR-Spektroskopie des menschlichen Herzens mittels CORRECT-SLIM T1 - Quantitative mr-spectroscopy of the human heart by CORRECT-SLIM N2 - Die 31P-MRS ermöglicht die nicht-invasive Untersuchung des kardialen Energiestoffwechsels sowie die Absolutquantifizierung der Metaboliten des kardialen Energiestoffwechsels. Mit dem schnellen Siegeszug der MR-Bildgebung in der klinischen Routine im Bereich kardiologischer Fragestellungen konnte die MRS bis in die heutige Zeit hinein jedoch nicht Schritt halten. Bedingt durch technische Limitationen konnte der Einsatz der MR-Spektroskopie des menschlichen Herzens hier bisher noch nicht Fuß fassen. Eine Weiterentwicklung mit dem Ziel der Etablierung der MRS in der klinischen Routine würde der Medizin neue Wege in Diagnostik und Patientenmonitoring ermöglichen. So wäre die Entwicklung eines kombinierten MRI/MRS-Protokolles für ein kardiales Langzeitmonitoring bei Kindern/Jugendlichen sowie bei erwachsenen Patienten mit unterschiedlichen Herzerkrankungen eine lohnende Aufgabe. Nur sehr wenige Arbeiten konnten bisher Ergebnisse zum Energiestoffwechsel und den Verhältnissen und Konzentration im rechten Ventrikel liefern. Durch die Entwicklung eines verbesserten Auswertealgorithmus (CORRECT-SLIM) am Institut für Röntgendiagnostik der Universität Würzburg könnten nun erstmals neue Aussagen hierzu möglich werden. Mit CORRECT-SLIM stellen wir erstmals ein Verfahren zur Absolutquantifizierung vor, das die Kontamination des Myokards des linken und rechten Ventrikel aus Brustwandarealen reduziert. Das Ziel der vorliegenden Arbeit war es, das neue Auswerteverfahren CORRECT-SLIM (Contamination Reduction in the Reconstruction with Spectral Localization by Imaging) systematisch sowohl am linken als auch am rechten Ventrikel des Herzens anzuwenden um hierdurch neue Aussagen zum Energiestoffwechsel des gesamten Herzens zu erhalten bzw. die Entwicklung und Verbesserung der bisherigen Auswerteverfahren (SLOOP) im Bereich der 31P-MRS Untersuchungen voranzutreiben. Hierzu wurden spektroskopische Untersuchungen am Myokard gesunder und kardial erkrankter Probanden durchgeführt. Die kardial erkrankten Patienten wiesen alle eine Hypertrophie des linken und/oder rechten Ventrikels auf, womit ein für die spektroskopische Auswertung erhöhtes Volumen zur Verfügung stand, was gerade im Hinblick auf die geringe physiologische Wandstärke des rechten Ventrikels erwünscht war und die Festlegung der Segmentationsgrenzen erleichterte. N2 - 31P-MRS allows the non-invasive examination of the cardiac high-energy phosphate metabolism and furthermore the absolute quantification of the high-energy phosphor metabolites. Due to the rapid progress of the MR imaging techniques and applications in the field of cardiology it is now used as a common instrument in the all-day clinical routine. Despite of it’s rapid progress in the field of the cardiac imaging techniques the 31P-MRS couldn’t be integrated into the clinical routine until today, due to technical limitations. Integration and development of the 31P-MRS technique in the clinical routine could offer new possibilities in diagnostic approaches and patient monitoring. The development of a combined MRI/31P-MRS-protocol for a cardiovascular long-time monitoring of cardiac diseases could be of great benefit. Only few publications concerning the energy metabolism of the right human cardiac ventricle have been made until today. By the development of a new evaluation- and quantification-algorithm (CORRECT-SLIM) new findings could be possible. With CORRECT-SLIM we introduce a new method for the absolute quantification of cardiac high-energy phosphates. It reduces the contamination of the left and right ventricle signal by the skeletal-muscle of the chest wall. The aim of the following study was to evaluate the CORRECT-SLIM algorithm (Contamination Reduction in the Reconstruction with Spectral Localization by Imaging) systematically for the cardiac high-energy metabolism of the left as well as for the right ventricle of the human heart and compare it to other evaluation/quantification-methods (SLOOP). The spectroscopic analysis involved the left and right ventricle of healthy volunteers and patients with hypertrophic heart disease as well as severe aortic stenosis. KW - Phosphor-31-NMR-Spektroskopie KW - Herzstoffwechsel KW - Quantifizierung KW - 31P-MRS KW - MR-Spektroskopie KW - Absolutquantifizierung KW - Phosphormetaboliten KW - mrs KW - cardiac spectroscopy KW - high-energy-phosphate metabolism Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-49005 ER -