TY - JOUR A1 - Fröhlich, Matthias A1 - Serfling, Sebastian A1 - Higuchi, Takahiro A1 - Pomper, Martin G. A1 - Rowe, Steven P. A1 - Schmalzing, Marc A1 - Tony, Hans-Peter A1 - Gernert, Michael A1 - Strunz, Patrick-Pascal A1 - Portegys, Jan A1 - Schwaneck, Eva-Christina A1 - Gadeholt, Ottar A1 - Weich, Alexander A1 - Buck, Andreas K. A1 - Bley, Thorsten A. A1 - Guggenberger, Konstanze V. A1 - Werner, Rudolf A. T1 - Whole-Body [\(^{18}\)F]FDG PET/CT Can Alter Diagnosis in Patients with Suspected Rheumatic Disease JF - Diagnostics N2 - The 2-deoxy-d-[\(^{18}\)F]fluoro-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT) is widely utilized to assess the vascular and articular inflammatory burden of patients with a suspected diagnosis of rheumatic disease. We aimed to elucidate the impact of [\(^{18}\)F]FDG PET/CT on change in initially suspected diagnosis in patients at the time of the scan. Thirty-four patients, who had undergone [\(^{18}\)F]FDG PET/CT, were enrolled and the initially suspected diagnosis prior to [18F]FDG PET/CT was compared to the final diagnosis. In addition, a semi-quantitative analysis including vessel wall-to-liver (VLR) and joint-to-liver (JLR) ratios was also conducted. Prior to [\(^{18}\)F]FDG PET/CT, 22/34 (64.7%) of patients did not have an established diagnosis, whereas in 7/34 (20.6%), polymyalgia rheumatica (PMR) was suspected, and in 5/34 (14.7%), giant cell arteritis (GCA) was suspected by the referring rheumatologists. After [\(^{18}\)F]FDG PET/CT, the diagnosis was GCA in 19/34 (55.9%), combined GCA and PMR (GCA + PMR) in 9/34 (26.5%) and PMR in the remaining 6/34 (17.6%). As such, [\(^{18}\)F]FDG PET/CT altered suspected diagnosis in 28/34 (82.4%), including in all unclear cases. VLR of patients whose final diagnosis was GCA tended to be significantly higher when compared to VLR in PMR (GCA, 1.01 ± 0.08 (95%CI, 0.95–1.1) vs. PMR, 0.92 ± 0.1 (95%CI, 0.85–0.99), p = 0.07), but not when compared to PMR + GCA (1.04 ± 0.14 (95%CI, 0.95–1.13), p = 1). JLR of individuals finally diagnosed with PMR (0.94 ± 0.16, (95%CI, 0.83–1.06)), however, was significantly increased relative to JLR in GCA (0.58 ± 0.04 (95%CI, 0.55–0.61)) and GCA + PMR (0.64 ± 0.09 (95%CI, 0.57–0.71); p < 0.0001, respectively). In individuals with a suspected diagnosis of rheumatic disease, an inflammatory-directed [\(^{18}\)F]FDG PET/CT can alter diagnosis in the majority of the cases, particularly in subjects who were referred because of diagnostic uncertainty. Semi-quantitative assessment may be helpful in establishing a final diagnosis of PMR, supporting the notion that a quantitative whole-body read-out may be useful in unclear cases. KW - giant cell arteritis KW - GCA KW - [18F]FDG PET/CT KW - vasculature KW - inflammation KW - polymyalgia rheumatica KW - PMR KW - vasculitis Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-250227 SN - 2075-4418 VL - 11 IS - 11 ER - TY - THES A1 - Fritz, Dorothée Ulrike T1 - Retrospektive Analyse der computertomographisch gesteuerten Punktionen an einem Kollektiv von 951 Patienten T1 - Retrospective review of CT-guided biopsies performed on 951 patients N2 - Ziel dieser Arbeit war es, den Stellenwert der CT-gesteuerten Punktion hinsichtlich Komplikationsrate, nicht auswertbaren Biopsien, deren statistische Kenngrößen in der Gesamtheit und deren Zusammenhang bezüglich Nadelgröße, Punktionsweg und Läsionsgröße zu ermitteln. Insgesamt konnte retrospektiv ein Kollektiv von 1019 Punktionen an 951 Patienten im Institut für Röntgendiagnostik der Universität Würzburg mit einem Follow-up von 2 Jahren untersucht werden. Es konnten in 96 % der Fälle vom Pathologen auswertbare Proben gewonnen werden. Bei 951 Patienten konnten 38 Biopsien nicht histologisch ausgewertet werden. Es bestand ein signifikanter Zusammenhang bezüglich der Dicke der Biopsienadel und der histologischen Auswertbarkeit. 19/20 G Nadeln führten in 20 % der Fälle zu nicht beurteilbaren Proben, 15/16 G und 17/18 G Nadeln hingegen nur bei 1,8 % und 3,6 % der Punktionen. Bei komplikationslosen Punktionen ergaben sich seltener histologisch nicht auswertbare Proben (3,5 %) als bei Biopsien, die eine Komplikation verursachten bzw. nach sich zogen (6,3 %). Die Biopsien fanden in 57 % der Fälle mit 17/18 G Nadeln statt. Bei 40 % der Punktionen wurden 15/16 G Nadeln verwendet. In lediglich 4,3 % und 6,7 % der Fälle kamen 19/20 G Nadeln und Knochenstanzen zum Einsatz. In der Gesamtheit des Kollektivs ergab sich eine Sensitivität von 92 % bei einer Spezifität von 100 %. Die Kenngrößen variierten in den anatomischen Subgruppen. Von 951 Punktionen erwiesen sich 6,8 % als falsch negativ, 73,2 % als richtig positiv und 16,7 % als richtig negativ. 58 Bei Pankreas-Punktionen lag die falsch negativ Rate mit 23,1 % am höchsten. Niedrige falsch negativ Raten zeigten sich bei Pleura- (2,9 %), Lungen- (5,3 %) und Muskel-/Weichteilpunktionen (1,5 %). Als signifikant erwies sich der Zusammenhang zwischen Biopsienadelgröße und histologischem Ergebnis. Falsch negative Ergebnisse waren besonders bei Anwendungen von 19/20 G Nadeln zu verzeichnen (17,5 %). Bei 17/18 G Nadeln und Knochenstanzen traten insgesamt nur in 7,5 % und 7,9 % falsch negative Ergebnisse auf. Der Durchmesser der Läsion beeinflusste signifikant das histologische Ergebnis. Bei falsch negativen Ergebnissen betrug der Durchmesser im Mittelwert 3,4 cm. Bei richtig positiven Punktionen lag der Läsionsdurchmesser bei 4,1 cm. In 18,4 % der Fälle führte eine Probeentnahme zu einer Komplikation. Davon erwiesen sich 14,8 % als Minor- und 3,6 % als Majorkomplikation, wie zum Beispiel ein Pneumothorax mit Notwendigkeit einer Drainagelegung. Die meisten Komplikationen traten bei Punktionen der Lunge (14 %) auf. Dabei zeigten die Nadeln 19/20 G mit 40 % die höchste Komplikationsrate. Dies ist nicht der Tatsache geschuldet, dass die dünneren Nadeln vorwiegend bei tiefen Läsionen zum Einsatz kamen. Auch bei tieferen Punktionen ist die Komplikationsrate der dickeren Nadeln geringer, als die der dünnen. 15/16 G Nadeln kamen bei einer durchschnittlichen Tiefe von 5,6 cm zum Einsatz, 17/18 G Nadeln bei 6,6 cm und 19/20 G Nadeln bei 7,2 cm. Betrachtet man jedoch die Nadelgruppen 17/18 G und 19/20 G für sich, zeigte sich, dass der Abstand zur Haut bei Komplikationen nicht größer war, als ohne Komplikation. Bei 15/16 G Nadeln war der Punktionsweg bei Komplikationen signifikant größer als bei Punktionen ohne Komplikation. Bei Lungenpunktionen im Speziellen war der Punktionsweg ebenfalls für 15/16 G länger, wenn ein Pneumothorax aufgetreten ist, als bei komplikationslosen Biopsien. 59 Es zeigte sich, dass bei Wiederholungspunktionen die Läsionen tiefer lagen, als bei einmaligen Punktionen. Die Läsionsgröße lag durchschnittlich bei 4 cm. Beim Auftreten einer Komplikation erwies sich der Durchmesser der Läsion, besonders für Lungenbiopsien, als signifikant kleiner (MV = 3,5), als bei komplikationslosen Biopsien. Ein wichtiger Faktor für die Treffsicherheit, den positiven Vorhersagewert und die Komplikationsrate spielte die Erfahrung des jeweiligen Punkteurs. Diese Arbeit konnte belegen, dass der Radiologe mit 20 Jahren Erfahrung die niedrigste Komplikationsrate (15 %) und gleichzeitig die geringste falsch negativ Rate (12 %) hatte. N2 - Purpose: The CT-guided biopsy is a well-established technique for the diagnosis of unknown lesions. The objective of this study was to evaluate the diagnostic accuracy of CT-guided biopsies, in the context of needle size, complication rate, lesion size and the radiologists experience in a representative number of patients. Method: The results of 1019 CT-guided biopsies in 951 patients were evaluated with regard to sensitivity, specificity and complication rate of the chosen needle sizes. A 17/18 g needle was used in 544 cases, a 19/20 g needle in 40 cases and a 15/16 g needle was used in 351 cases. Lesion size, depth and location were included as variables. Results: The biopsies yielded sufficient histology material in 913 of 951 (96%) cases. The rate of insufficient histology material increased significantly when a smaller needle size was used (20% when a 19/20 g needle was used). The false negative rate (6,8%) was influenced by needle size (17,5% at 19/29 g) and lesion size. Overall the sensitivity, specificity and diagnostic accuracy were 92%, 100% and 93%. Complications were noted in 18,4% of all cases. The most major-complication was pneumothorax (3%), which required chest tube drainages. Conclusion: With 15/16 g and 17/18 G needle sizes, diagnostic accuracy can be drastically increased without an increase in the complication rate. KW - Computertomograph KW - Punktion KW - Diagnostik KW - Komplikation KW - CT-gesteuerte Punktion KW - Maligne Tumoren KW - Raumforderung KW - Stanzbiopsie KW - Pneumothorax Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126347 ER - TY - JOUR A1 - Frey, Anna A1 - Gassenmaier, Tobias A1 - Hofmann, Ulrich A1 - Schmitt, Dominik A1 - Fette, Georg A1 - Marx, Almuth A1 - Heterich, Sabine A1 - Boivin-Jahns, Valérie A1 - Ertl, Georg A1 - Bley, Thorsten A1 - Frantz, Stefan A1 - Jahns, Roland A1 - Störk, Stefan T1 - Coagulation factor XIII activity predicts left ventricular remodelling after acute myocardial infarction JF - ESC Heart Failure N2 - Aims Acute myocardial infarction (MI) is the major cause of chronic heart failure. The activity of blood coagulation factor XIII (FXIIIa) plays an important role in rodents as a healing factor after MI, whereas its role in healing and remodelling processes in humans remains unclear. We prospectively evaluated the relevance of FXIIIa after acute MI as a potential early prognostic marker for adequate healing. Methods and results This monocentric prospective cohort study investigated cardiac remodelling in patients with ST-elevation MI and followed them up for 1 year. Serum FXIIIa was serially assessed during the first 9 days after MI and after 2, 6, and 12 months. Cardiac magnetic resonance imaging was performed within 4 days after MI (Scan 1), after 7 to 9 days (Scan 2), and after 12 months (Scan 3). The FXIII valine-to-leucine (V34L) single-nucleotide polymorphism rs5985 was genotyped. One hundred forty-six patients were investigated (mean age 58 ± 11 years, 13% women). Median FXIIIa was 118 % (quartiles, 102–132%) and dropped to a trough on the second day after MI: 109%(98–109%; P < 0.001). FXIIIa recovered slowly over time, reaching the baseline level after 2 to 6 months and surpassed baseline levels only after 12 months: 124 % (110–142%). The development of FXIIIa after MI was independent of the genotype. FXIIIa on Day 2 was strongly and inversely associated with the relative size of MI in Scan 1 (Spearman’s ρ = –0.31; P = 0.01) and Scan 3 (ρ = –0.39; P < 0.01) and positively associated with left ventricular ejection fraction: ρ = 0.32 (P < 0.01) and ρ = 0.24 (P = 0.04), respectively. Conclusions FXIII activity after MI is highly dynamic, exhibiting a significant decline in the early healing period, with reconstitution 6 months later. Depressed FXIIIa early after MI predicted a greater size of MI and lower left ventricular ejection fraction after 1 year. The clinical relevance of these findings awaits to be tested in a randomized trial. KW - blood coagulation factor XIII KW - ST-elevation myocardial infarction KW - healing and remodelling processes KW - cardiac magnetic resonance imaging Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-236013 VL - 7 IS - 5 ER - TY - THES A1 - Fischer, Monika T1 - Nicht operierte Sagittalnahtsynostosen im Verlauf T1 - Radiographic Changes in Non-Operated Sagittal Suture Synostosis N2 - Zur Darstellung des Verlaufs bei nicht operierten Kindern mit Sagittalsynostose wurden 155 Röntgenbilder von 52 Patienten im Alter zwischen 15 Tagen und 9 Jahren untersucht. Die Schädelnähte wurden hinsichtlich der Darstellbarkeit, Begrenzung, Zähnelung und Aktivität beurteilt. Weiterhin wurden acht Strecken und vier Winkel gemessen, daraus zwei Indizes berechnet. Die Sagittalnaht war bei mehr als der Hälfte der Aufnahmen im ersten Lebensjahr partiell bzw. vollständig darstellbar. Die Lambdanaht war ab dem zweiten Lebensmonat immer, die Coronarnaht bis auf wenige Ausnahmen darstellbar. Die Zähnelung der Nähte entwickelte sich altersentsprechend. Der Anteil der Nähte, die keine erhöhte Aktivität aufwiesen, sank im Verlauf von 94% auf 38%. Bei den Messstrecken und Winkeln wurden die Ergebnisse aus der Literatur weitgehend bestätigt. Der Basiswinkel war im untersuchten Patientenkollektiv signifikant erhöht. Der Höhenindex näherte sich im Verlauf der Altersnorm an, wohingegen sich die Parameter innere Schädelbreite und Breiten-Längen-Index signifikant von der Altersnorm entfernten. Der Skaphozephalus wächst sich nicht aus, aber einzelne Merkmale, wie die parietale Wölbung,nähern sich wieder etwas der Norm an. Sichere Hinweise für ein Übergreifen der Synostose auf andere Nähte wurden nicht gefunden. Im weiteren wurden digitale und konventionelle Röntgenaufnahmen von 33 Patienten mit Kraniostenosen verglichen. Untersucht wurde die Beurteilbarkeit hinsichtlich Schärfe und Kontrast. Der Zeitabstand zwischen konventioneller und digitaler Röntgenaufnahme lag im Mittel bei 24 Monaten. Die Vorteile des digitalen Röntgens hinsichtlich der Beurteilbarkeit konnten deutlich gezeigt werden. Somit ist das optimierte digitale Röntgensystem dem konventionellen vorzuziehen. N2 - Purpose: To characterize the spontaneous clinical course of isolated sagittal synostosis based on planar skull radiography. Materials and Methods: In this retrospective analysis we evaluated a total of 155 radiographs of 55 children 2 weeks to 9 years old. The sagittal, coronal and lambdoid sutures were evaluated on the basis of pairs of ap and lateral radiographs. The sutures were examined with respect to their boundary, activity, and conspicuity to be visualized (based on a 3-grade score system). Six selected points on the skull X-ray defined eight measured distances, three angles, and a width-length index. To document changes over time, the measurements were correlated to normal values. In addition, a correlation between suture activity and selected parameters was evaluated. Results: The sagittal suture could be continuously or partially depicted in more then half of all radiographs taken during the first year of life. The measured distances and angles were concordant with results from the literature. With increasing age, the width-length index deviated from standard values while other parameters approximated the norm. Conclusion: In the case of children younger than twelve months, the sagittal suture appears radiologically open in many cases despite clear-cut scaphocephaly. Definite signs of progressive plurisutural fusion were not found in this series. The dolichocephalic deformity remained unchanged while some signs of scaphocephalic appearance actually improved. Key words KW - Kraniostenose KW - Konservative Therapie KW - Radiologie KW - Vergleich konservative digitale Röntgentechnik KW - pathology KW - skull KW - radiography Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-24310 ER - TY - THES A1 - Feldner, Natascha Christina Maria T1 - Die interventionelle Therapie von Lebertumoren - Würzburger Ergebnisse und Verträglichkeit der transarteriellen Chemoembolisation (TACE) T1 - Interventional therapy of livertumours - A study from the university of Würzburg on tolerability of TACE N2 - Zusammenfassung Einleitung: Die Therapie der Lebertumore stellt nach wie vor eine Herausforderung für alle beteiligten Disziplinen dar. Die Universitätskliniken Würzburg verfügen über ein interdisziplinäres Therapiekonzept. Diese Studie aus der Abteilung für Röntgendiagnostik der Universität Würzburg ist ein Vergleich der eigenen Ergebnisse nach interventionellen Therapien von Lebertumoren, im Speziellen nach TACE, mit Daten der Literatur. Besonders berücksichtigt wurden die Auswirkungen auf die Lebensqualität und mögliche Komplikationen. Material und Methode: Von September 1994 bis April 2003 wurden die Lebertumore von 54 Patienten mit insgesamt 135 transarteriellen Chemoembolisationen (TACE) behandelt. Berücksichtigt wurden das Verhalten des Tumors, die Entwicklung des Karnofsky-Index, die Dauer des stationären Aufenthalts, die Kombination mit weiteren Therapieoptionen, die Überlebenszeit für die Monotherapie mit TACE und die Kombinationstherapie aus TACE und PEI / RFA, die Entwicklung ausgewählter Laborparameter, das Auftreten von Nebenwirkungen und Beschwerden nach TACE, die Ausprägung des Postembolisationssyndroms sowie aufgetretene Komplikationen und Embolisatverschleppungen. Ergebnisse: Die TACE hat sich unter Beachtung ihrer Kontraindikationen und der jeweiligen Situation des einzelnen Patienten als sichere und effektive Methode für die palliative Therapie von Lebertumoren erwiesen. Sie führt zu einer Verlängerung der Überlebenszeit, wobei sich die Kombination aus TACE und PEI / RFA der Monotherapie mit TACE überlegen darstellte. Auftretende Nebenwirkungen sind in der Regel vorübergehend, schwere Komplikationen und wesentliche Einschränkungen der Lebensqualität traten nur in Einzelfällen auf. Schlussfolgerung: Die Ergebnisse aus unserer Abteilung weisen eine gute Verträglichkeit der TACE für die Patienten nach und unterstreichen ihren Stellenwert in der Therapie primär inoperabler Lebertumore. N2 - Abstract Background and aims: The therapy of livertumours is still a challenge for all involved disciplines. The clinics of the university of Würzburg are using an interdisciplinary therapy concept. The following study from the department for x-ray diagnostics of the university of Würzburg is a comparison between our results of the interventional therapies of the livertumours especially using the TACE, with data from the literature. A special focus was made on the effects on the quality of life and possible complications. Materials and methods: From September 1994 to April 2003 54 patients with livertumours were treated with in all 135 transarterial chemoembolizations (TACE). Certain aspects were evaluated, such as the reaction of the tumours, the development of the Karnofsky-index, the duration of the stationary treatments, the combination with additional therapies, the survival rate with a single therapy with TACE alone and with a combination therapy consisting of TACE and PEI / RFA, the development of chosen laboratory parameters, the occurrence of side effects and complaints after the use of the TACE therapy, the development of the postembolisations syndromes as well as accruing complications and embolisations protractions. Results: The TACE has proven itself to be a safe and effective method for the palliative therapy of livertumours while considering the contraindications and the individual situations of the patients. The therapy leads a lengthening of the survival, whereas the combination of TACE and PEI / RFA has shown to be superior to the therapy consisting of TACE alone. Occurring side effects are usually only temporary, heavy complications and essential restrictions in the quality of life occurred only in isolated cases. Conclusion: The results form our department prove a good tolerability of the TACE for patients and underline its place value in the therapy of primarily inoperable livertumour. KW - Lebensqualität KW - interventionelle Therapie KW - Lebertumore KW - hepatozelluläres Karzinom (HCC) KW - transarterielle Chemomebolisation (TACE) KW - interventional therapy KW - livertumour KW - transarterial chemoembolization (TACE) KW - quality of life KW - hepatocellular carcinoma (HCC) Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-36504 ER - TY - JOUR A1 - Fabritius, Matthias Philipp A1 - Wölfer, Teresa A. A1 - Herzberg, Moriz A1 - Tiedt, Steffen A1 - Puhr-Westerheide, Daniel A1 - Grosu, Sergio A1 - Maurus, Stefan A1 - Geyer, Thomas A1 - Curta, Adrian A1 - Kellert, Lars A1 - Küpper, Clemens A1 - Liebig, Thomas A1 - Ricke, Jens A1 - Dimitriadis, Konstantinos A1 - Kunz, Wolfgang G. A1 - Zimmermann, Hanna A1 - Reidler, Paul T1 - Course of early neurologic symptom severity after endovascular treatment of anterior circulation large vessel occlusion stroke: association with baseline multiparametric CT imaging and clinical parameters JF - Diagnostics N2 - Background: Neurologic symptom severity and deterioration at 24 hours (h) predict long-term outcomes in patients with acute large vessel occlusion (LVO) stroke of the anterior circulation. We aimed to examine the association of baseline multiparametric CT imaging and clinical factors with the course of neurologic symptom severity in the first 24 h after endovascular treatment (EVT). Methods: Patients with LVO stroke of the anterior circulation were selected from a prospectively acquired consecutive cohort of patients who underwent multiparametric CT, including non-contrast CT, CT angiography and CT perfusion before EVT. The symptom severity was assessed on admission and after 24 h using the 42-point National Institutes of Health Stroke Scale (NIHSS). Clinical and imaging data were compared between patients with and without early neurological deterioration (END). END was defined as an increase in ≥4 points, and a significant clinical improvement as a decrease in ≥4 points, compared to NIHSS on admission. Multivariate regression analyses were used to determine independent associations of imaging and clinical parameters with NIHSS score increase or decrease in the first 24 h. Results: A total of 211 patients were included, of whom 38 (18.0%) had an END. END was significantly associated with occlusion of the internal carotid artery (odds ratio (OR), 4.25; 95% CI, 1.90–9.47) and the carotid T (OR, 6.34; 95% CI, 2.56–15.71), clot burden score (OR, 0.79; 95% CI, 0.68–0.92) and total ischemic volume (OR, 1.01; 95% CI, 1.00–1.01). In a comprehensive multivariate analysis model including periprocedural parameters and complications after EVT, carotid T occlusion remained independently associated with END, next to reperfusion status and intracranial hemorrhage. Favorable reperfusion status and small ischemic core volume were associated with clinical improvement after 24 h. Conclusions: The use of imaging parameters as a surrogate for early NIHSS progression in an acute LVO stroke after EVT reached limited performance with only carotid T occlusion as an independent predictor of END. Reperfusion status and early complications in terms of intracranial hemorrhage are critical factors that influence patient outcome in the acute stroke phase after EVT. KW - stroke KW - large vessel occlusion KW - multiparametric CT KW - CT perfusion KW - CT angiography KW - NIHSS KW - EVT Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-242681 SN - 2075-4418 VL - 11 IS - 7 ER - TY - JOUR A1 - Ewald, Andrea A1 - Fuchs, Andreas A1 - Boegelein, Lasse A1 - Grunz, Jan-Peter A1 - Kneist, Karl A1 - Gbureck, Uwe A1 - Hoelscher-Doht, Stefanie T1 - Degradation and bone-contact biocompatibility of two drillable magnesium phosphate bone cements in an in vivo rabbit bone defect model JF - Materials N2 - The use of bone-cement-enforced osteosynthesis is a growing topic in trauma surgery. In this context, drillability is a desirable feature for cements that can improve fracture stability, which most of the available cement systems lack. Therefore, in this study, we evaluated a resorbable and drillable magnesium-phosphate (MgP)-based cement paste considering degradation behavior and biocompatibility in vivo. Two different magnesium-phosphate-based cement (MPC) pastes with different amounts of phytic acid (IP 6) as setting retarder (MPC 22.5 and MPC 25) were implanted in an orthotopic defect model of the lateral femoral condyle of New Zealand white rabbits for 6 weeks. After explantation, their resorption behavior and material characteristics were evaluated by means of X-ray diffraction (XRD), porosimetry measurement, histological staining, peripheral quantitative computed tomography (pQCT), cone-beam computed tomography (CBCT) and biomechanical load-to-failure tests. Both cement pastes displayed comparable results in mechanical strength and resorption kinetics. Bone-contact biocompatibility was excellent without any signs of inflammation. Initial resorption and bone remodeling could be observed. MPC pastes with IP 6 as setting retardant have the potential to be a valuable alternative in distinct fracture patterns. Drillability, promising resorption potential and high mechanical strength confirm their suitability for use in clinical routine. KW - magnesium phosphate cement KW - phytic acid KW - drillability KW - bone replacement material Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-362824 SN - 1996-1944 VL - 16 IS - 13 ER - TY - THES A1 - Evangelista, Laura T1 - Innovative Anwendungen der diffusionsgewichteten MRT in der pädiatrischen muskuloskelettalen Bildgebung T1 - Innovative applications of diffusion-weighted MRI in pediatric musculoskeletal imaging analisys N2 - Die vorliegende Arbeit untesucht die Darstellung tumoröser und entzündlicher muskuloskelettaler Läsionen mit der diffusionsgewichteten MRT-Bildgebung bei Kindern und Jugendlichen. Es sollten die Machbarkeit und die Zuverlässigkeit der Methode in der klinischen Routinebildgebung überprüft werden. Zusätzlich untersuchten wir den Einsatz von ADC-Werten zur Differenzierung von malignen und benignen Tumoren sowie bei inflammatorischen Knochen- und Weichteilbefunden. Wie die klassische MRT, ist die diffusionsgewichtete Bildgebung nicht-invasiv: da der Bildkontrast allein mittels magnetischer Feldgradienten erzielt wird, erfordert sie weder eine Injektion von Kontrastmitteln, noch den Einsatz von ionisierender Strahlung. Sie garantiert eine schnelle Aquisitionstechink um Artefakte zu begrenzen und die Untersuchungen kindergerechter zu gestalten. Die von uns erfassten Daten wurden in zwei unterschiedlichen Studien aufgeteilt. Die Erste Studie erfasst Ergebnisse bzgl. der Detektion und Dignitätsabschätzung kinderlicher muskuloskelettaler Tumoren mittels diffusionsgewichteten MRT Bilder. Das zweite Forschungsprojekt, befasst sich mit dem erstmaligen Einsatz der diffusionsgewichteten MRT zur Identifikation und Differenzierung von Knochenmarködem, Weichteilödem und Synovitis bei pädiatrischen Patienten. N2 - This study investigates the presentation of tumorous and inflammatory musculoskeletal lesions by diffusion-weighted MRI imaging in children and adolescents. The feasibility and reliability of the method should be tested in clinical routine imaging. In addition, we investigated the use of ADC values ​​for the differentiation of malignant and benign tumors as well as for inflammatory bone and soft tissue findings. Like the classical MRI, diffusion-weighted imaging is non-invasive: since the image contrast is achieved solely by means of magnetic field gradients, it does not require either the injection of contrast agents or the use of ionizing radiations. This technique allows a quick aquisition to limit artefacts and to shape the investigations in a more child-friendly way. The data we collected were divided into two different studies. The first study records results concerning the detection and dignity-assessment of childhood musculoskeletal tumors using diffusion-weighted MRI images. The second research project deals with the initial use of diffusion-weighted MRI for the identification and differentiation of bone marrow edema, soft tissue edema and synovitis in Pediatric patients. KW - Diffusionsgewichtete Magnetresonanztomographie KW - Diffusions-MRT KW - DW-MRI KW - Pädiatrie KW - muskuloskelettalen Bildgebung KW - pädiatrischen Tumoren Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-145065 ER - TY - JOUR A1 - Elsner, Clara A1 - Kunz, Andreas Steven A1 - Wagner, Nicole A1 - Huflage, Henner A1 - Hübner, Stefan A1 - Luetkens, Karsten Sebastian A1 - Bley, Thorsten Alexander A1 - Schmitt, Rainer A1 - Ergün, Süleyman A1 - Grunz, Jan-Peter T1 - MRI-based evaluation of the flexor digitorum superficialis anatomy: investigating the prevalence and morphometry of the “chiasma antebrachii” JF - Diagnostics N2 - Recent dissection studies resulted in the introduction of the term “chiasma antebrachii”, which represents an intersection of the flexor digitorum superficialis (FDS) tendons for digits 2 and 3 in the distal third of the forearm. This retrospective investigation aimed to provide an MRI-based morphologic analysis of the chiasma antebrachii. In 89 patients (41 women, 39.3 ± 21.3 years), MRI examinations of the forearm (2010–2021) were reviewed by two radiologists, who evaluated all studies for the presence and length of the chiasma as well as its distance from the distal radioulnar and elbow joint. The chiasma antebrachii was identified in the distal third of the forearm in 88 patients (98.9%), while one intersection was located more proximally in the middle part. The chiasma had a median length of 28 mm (interquartile range: 24–35 mm). Its distances to the distal radioulnar and elbow joint were 16 mm (8–25 mm) and 215 mm (187–227 mm), respectively. T1-weighted post-contrast sequences were found to be superior to T2- or proton-density-weighted sequences in 71 cases (79.8%). To conclude, the chiasma antebrachii is part of the standard FDS anatomy. Knowledge of its morphology is important, e.g., in targeted injections of therapeutics or reconstructive surgery. KW - flexor digitorum superficialis KW - flexor tendon KW - chiasma antebrachii KW - magnetic resonance imaging Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-362631 SN - 2075-4418 VL - 13 IS - 14 ER - TY - JOUR A1 - Duhr, Carolin D. A1 - Kenn, Werner A1 - Kickuth, Ralph A1 - Kerscher, Alexander G. A1 - Germer, Christoph-Thomas A1 - Hahn, Dietbert A1 - Pelz, Joerg O. W. T1 - Optimizing of preoperative computed tomography for diagnosis in patients with peritoneal carcinomatosis JF - World Journal of Surgical Oncology N2 - Background and Objective This study evaluates whether Computer Tomography is an effective procedure for preoperative staging of patients with Peritoneal Carcinomatosis. Method A sample of 37 patients was analyzed with contrast enhanced abdominal Computer Tomography, followed by surgical staging. All Computer Tomography scans were evaluated 3 times by 2 radiologists with one radiologist reviewing 2 times. The efficacy of Computer Tomography was evaluated using the Spearman correlation coefficient. Correlations were analyzed by abdominopelvic region to assess results of the Peritoneal Carcinomatosis Index (PCI) aggregating the 13 regions. Surgical findings were compared to radiological findings. Results Results indicate high correlations between the surgical and radiological Peritoneal Carcinomatosis Indices. Analyses of the intra-class correlation between the first and second reading of one radiologist suggest high intra-observer reliability. Correlations by abdominopelvic region show higher values in the upper and middle regions and relatively lower values in the lower regions and the small bowel (correlation coefficients range between 0.418 and 0.726, p < 0.010; sensitivities range between 50% and 96%; and specificities range between 62% and 100%). Conclusion Computer Tomography represents an effective procedure in the preoperative staging of patients with PC. However, results by abdominopelvic region show lower correlation, therefore suggest lower efficacy. These results are supported by analyses of sensitivity and accuracy by lesion size. This suggests that Computer Tomography is an effective procedure for pre-operative staging but less for determining a tumor's accurate extent. KW - Carcinomatosis KW - diagnosis KW - PCI Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-138024 VL - 9 IS - 171 ER - TY - THES A1 - Dragolea, Darius T1 - Ergebnisqualität von klinischen und Vorsorgemammographien im Vergleich zu internationalen Leitlinien für Brustkrebsscreening T1 - The quality of the results of diagnostic and screening mammographic examinations in comparison with international breast cancer screening guidelines N2 - Durch den mehrfachen Führungswechsel in der Radiologischen Abteilung der Frauenklinik der Universität Würzburg seit 1995, ergab sich die Frage, ob die verantwortlichen Radiologen sich in der Mammographiebeurteilung unterscheiden. Ausgehend von 8033 Mammographien von asymptomatischen- und Patientinnen mit einem klinischen Befund, wurde die Sensitivität, Spezifität, die Biopsierate, die Tumorentdeckung- und Recallrate für die einzelnen Untersucher ermittelt. Die wesentlichen Ergebnisse dieser Arbeit sind: 1. Die Sensitivität liegt bei durchschnittlich 97,14%, die Spezifität 98,62%. Die Tumorentdeckungsrate liegt zwischen 6,59‰ und 8,99‰, die Biopsierate beträgt 1,34% und die Recallrate 3,79%. 2. Für alle Behandler liegen diese Werte innerhalb der vom American College of Radiology und den European Guidelines for Quality Assurance in Mammography Screening vorgegebenen Richtlinien. 3. Es gibt keine signifikanten Unterschiede in der Mammographiebefundung durch die verschiedenen Untersucher. 4. Durch die Einführung der standardisierten Klassifikation der Befunde wird in Zukunft eine Qualitätssicherung der Mammographieuntersuchungen und eine Kontrolle der Ergebnisse gewährleistet. N2 - The frequent changes of management in the Radiological Department of the Gynaecological Clinic of the University of Würzburg since 1995 gave rise to the question of whether the radiologists responsible differed in their assessments of mammographical examinations. The sensitivity, specifity, biopsy rate, cancer detection rate and recall rate were calculated for each inidividual examining physician on the basis of 8033 mammographies of asymptomatic patients and patients with clinical symptoms. The primary results of this study were as follows: 5. The average sensitivity came to 97.14% and the average specifity came to 98.62%. The cancer detection rate was between 6.59‰ and 8.99‰, the biopsy rate was 1.34% and the recall rate was 3.79%. 6. These values fell within the guidelines specified by the American College of Radiology and the European Guidelines for Quality Assurance in Mammography Screening for all examining physicians. 7. There were no significant differences between the individual examining physicians with respect to their mammographical assessments. 8. The introduction of the standardised classification of the assessments will in future guarantee quality assurance in mammographical examinations and ensure that the results can be monitored. KW - Mammographie KW - Sensitivität KW - Spezifität KW - Tumorentdeckungsrate KW - mammography KW - sensitivity KW - specifity KW - cancer detection rate Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12306 ER - TY - JOUR A1 - Dorn, Franziska A1 - Herzberg, Moriz T1 - Response to Letter to the Editor “Keeping Late Thrombectomy Imaging Protocols Simple to Avoid Analysis Paralysis” JF - Clinical Neuroradiology KW - neuroradiology KW - neurosurgery KW - neurology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-307023 SN - 1869-1439 SN - 1869-1447 VL - 31 IS - 3 ER - TY - THES A1 - Dietrich, Philipp T1 - Traveling Wave Magnetic Particle Imaging: Visuelle Stenosequantifizierung und Perkutane Transluminale Angioplastie im Gefäßmodell T1 - Traveling Wave Magnetic Particle Imaging: visual stenosis quantification and percutaneous transluminal angioplasty in a phantom model N2 - Magnetic Particle Imaging (MPI) ist ein innovatives tomographisches Bildgebungs­verfahren, mit dem Tracerpartikel äußerst sensitiv und schnell mehrdimensional abgebildet werden können. Die Methode basiert auf der nichtlinearen Magnetisierungs­antwort superparamagnetischer Eisenoxidnanopartikel (SPION) in einem Messpunkt, welcher ein Messvolumen rastert. In vorliegender Arbeit wurde das sog. Traveling Wave MPI (TWMPI) Verfahren eingesetzt, wodurch im Vergleich zu konventionellen MPI-Scannern ein größeres Field of View (FOV) und eine geringere Latenz bis zur Bildanzeige erreicht werden konnte. TWMPI weist einige für medizinische Zwecke vielversprechende Eigenschaften auf: Es liefert zwei- und dreidimensionale Bildrekonstruktionen in Echtzeit mit hoher zeitlicher und räumlicher Auflösung. Dabei ist die Bildgebung von Grund auf hintergrundfrei und erfordert keinerlei ionisierende Strahlung. Zudem ist die Technik äußerst sensitiv und kann SPION-Tracer noch in mikromolaren Konzentrationen detektieren. Ziel dieser Arbeit war es daher zu untersuchen, inwiefern es mittels TWMPI möglich ist, künstliche Stenosen im Gefäßmodell visuell in Echtzeit darzustellen und quantitativ zu beurteilen sowie überdies eine perkutane transluminale Angioplastie (PTA) im Gefäßmodell unter TWMPI-Echtzeit-Bildgebung durchzuführen. Alle Experimente wurden in einem speziell angefertigten TWMPI-Scanner durchgeführt (JMU Würzburg, Experimentelle Physik V (Biophysik), FOV: 65 x 29 x 29 mm³, Auflösung: ca. 1.5 - 2 mm). Die Lumen-Darstellungen erfolgten mittels des SPION-Tracers Ferucarbotran in einer Verdünnung von 1 : 50 (entspr. 10 mmol [Fe]/l). Das PTA-Instrumentarium wurde mit eigens hergestelltem ferucarbotran­haltigem Lack (100 mmol [Fe]/l) markiert. Für die verschiedenen Teilexperimente wurden den jeweiligen speziellen Anforderungen entsprechend mehrere Gefäßmodelle handgefertigt. Für die visuelle Stenosequantifizierung wurden fünf starre Stenosephantome unterschiedlicher Stenosierung (0%, 25%, 50%, 75%, 100%) aus Polyoxymethylen her­gestellt (l: 40 mm, ID: 8 mm). Die Gefäßmodelle wurden mehrfach zentral im FOV platz­iert und das stenosierte Lumen mittels sog. Slice-Scanning Modus (SSM, Einzel­aufnahme inkl. 10 Mittelungen: 200 ms, Bildfrequenz: 5 Bilder pro Sekunde, Latenz: ca. 100 ms) als zweidimensionale Quasi-Projektionen abgebildet. Diese Aufnahmen (n = 80, 16 je Phantom) wurden mit einer ein­heitlichen Grauskalierung versehen und anschließend entsprechend den NASCET-Kriterien visuell ausgewertet. Alle achtzig Aufnahmen waren unabhängig vom Stenosegrad aufgrund einheitlicher Fensterung sowie konstanter Scannerparameter untereinander gut vergleichbar. Niedrig­gradige Stenosen konnten insgesamt genauer abgebildet werden als höhergradige, was sich neben der subjektiven Bildqualität auch in geringeren Standardabweichungen zeigte (0%: 3.70 % ± 2.71, 25%: 18.64 % ± 1.84, 50%: 52.82 % ± 3.66, 75%: 77.84 % ± 14.77, 100%: 100 % ± 0). Mit zunehmendem Stenosegrad kam es vermehrt zu geometrischen Ver­zerrungen im Zentrum, sodass bei den 75%-Stenosen eine breitere Streuung der Messwerte mit einer höheren Standardabweichung von 14.77% einherging. Leichte, randständige Artefakte konnten bei allen Datensätzen beobachtet werden. Für die PTA wurden drei interaktive Gefäßmodelle aus Polyvinylchlorid (l: 100 mm, ID: 8 mm) mit zu- und abführendem Schlauchsystem entwickelt, welche mittels Kabelband von außen hochgradig eingeengt werden konnten. Analog zu einer konventionellen PTA mittels röntgenbasierter digitaler Subtraktionsangiographie (DSA), wurden alle erforder­lichen Arbeitsschritte (Gefäßdarstellung, Drahtpassage, Ballonplatzierung, Angioplastie, Erfolgskontrolle) unter (TW)MPI-Echtzeit-Bildgebung (Framerate: 2 - 4 FPS, Latenz: ca. 100 ms) abgebildet bzw. durchgeführt. Im Rahmen der PTA war eine Echtzeit-Visualisierung der Stenose im Gefäßmodell durch Tracer-Bolusgabe sowie die Führung des markierten Instrumentariums zum Zielort möglich. Die Markierung der Instrumente hielt der Beanspruchung während der Prozedur stand und ermöglichte eine genaue Platzierung des Ballonkatheters. Die Stenose konnte mittels Angioplastie-Ballons unter Echtzeit-Darstellung gesprengt werden und der Interventionserfolg im Anschluss durch erneute Visualisierung des Lumens validiert werden. Insgesamt zeigt sich MPI somit als adäquate Bildgebungstechnik für die beiden in der Fragestellung bzw. Zielsetzung definierten experimentellen Anwendungen. Stenosen im Gefäßmodell konnten erfolgreich in Echtzeit visualisiert und bildmorphologisch nach NASCET-Kriterien quantifiziert werden. Ebenso war eine PTA im Gefäßmodell unter TWMPI-Echtzeit-Bildgebung machbar. Diese Ergebnisse unter­streichen das grundlegende Potenzial von MPI für medizinische Zwecke. Um zu den bereits etablierten Bildgebungsmethoden aufzuschließen, ist jedoch weitere Forschung im Bereich der Scanner-Hard- und -Software sowie bezüglich SPION-Tracern nötig. N2 - Magnetic Particle Imaging (MPI) is an innovative tomographic imaging method with which tracer particles can be depicted multidimensionally quickly and extremely sensitively. The method is based on the nonlinear magnetization response of superparamagnetic iron oxide nanoparticles (SPION) in a measuring point that runs through a measurement volume. In the present work, the so-called Traveling Wave MPI (TWMPI) method was used, whereby a larger Field of View (FOV) and a lower latency from measurement to image display could be achieved compared to conventional MPI scanners. TWMPI has some promising properties for medical purposes: it delivers two- and three-dimensional image reconstructions in real time with high temporal and spatial resolution. The imaging is background-free by default and does not require any ionizing radiation. In addition, the technology is extremely sensitive and can detect SPION tracers in micromolar concentrations. The aim of this work was therefore to investigate to what extent it is possible to use TWMPI to graphically visualize and quantitatively assess artificial stenoses in a phantom model in real time and furthermore to perform a percutaneous transluminal angioplasty (PTA) in a phantom model under TWMPI real-time imaging. All experiments were carried out in a specially manufactured TWMPI scanner (JMU Würzburg, Experimental Physics V (Biophysics), FOV: 65 x 29 x 29 mm³, resolution: approx. 1.5 - 2 mm). Lumen visualization was achieved by use of the SPION tracer Ferucarbotran in a dilution of 1 : 50 (corresponding to 10 mmol [Fe] / l). The PTA instruments were marked with specially produced ferucarbotran-containing lacquer (100 mmol [Fe]/l). For the different sub-experiments, several vessel phantoms were custom-made according to the respective specific requirements. For visual stenosis quantification, five rigid stenosis phantoms of different grade of stenosis (0%, 25%, 50%, 75%, 100%) were built from polyoxymethylene (l: 40 mm, ID: 8 mm). The vessel phantoms were placed centrally in the FOV several times and the stenotic lumen was depicted as two-dimensional quasi-projections using a so-called slice scanning mode (SSM, single recording incl. averaging 10‑fold: 200 ms, frame rate: 5 frames per second, latency: approx. 100 ms). A uniform gray scaling was applied to these images (n = 80, 16 per phantom) before they were visually evaluated according to the NASCET criteria. Due to the uniform gray scaling, display settings and constant scanner parameters, all eighty images were well comparable with each other, regardless of the degree of stenosis. Overall, low-grade stenoses could be depicted more accurately than higher-grade ones, which, in addition to the subjective image quality, was also reflected in lower standard deviations (0%: 3.70 % ± 2.71, 25%: 18.64 % ± 1.84, 50%: 52.82 % ± 3.66, 75%: 77.84 % ± 14.77, 100%: 100 % ± 0). With increasing­ degree of stenosis, geometric distortions in the center increased, so that within the 75% stenoses a wider spread of the measured values led to a higher standard deviation of 14.77%. Faint, marginal artifacts could be observed over all data sets. For PTA, three interactive vessel phantoms made of polyvinyl chloride (l: 100 mm, ID: 8 mm) were developed with additional tubing to and from the phantom. These vessel phantoms could be highly constricted from the outside by use of cable ties. Analogous to a conventional PTA using X-ray-based digital subtraction angiography (DSA), all necessary steps (vascular visualization, wire passage, balloon placement, angioplasty, control imaging) were depicted by resp. carried out under (TW)MPI real-time imaging (frame rate: 2 – 4 FPS, latency: approx. 100 ms). During the PTA, real-time visualization of the stenosis in the vascular phantom by tracer bolus administration as well as guidance of the marked instruments to the destination was possible. The marking of the instruments withstood the stress during the procedure and allowed an accurate placement of the balloon catheter. The stenosis could be dilated with an angioplasty balloon under real-time imaging and the intervention success could then be validated by re-visualization of the lumen. Overall, MPI thus proves to be an adequate imaging technique in regard of the two experimental applications defined in the questions and aims of this study. Stenoses in a vascular phantom could be successfully visualized in real time and quantified visually according to NASCET criteria. Furthermore, a PTA in a vascular phantom guided by TWMPI real-time imaging was feasible. These findings underscore the fundamental potential of MPI for medical purposes. In order to catch up with the already established imaging methods, however, further research is needed in the field of scanner hard- and software as well as regarding SPION tracers. KW - Medizinische Radiologie KW - Magnetpartikelbildgebung KW - Interventionsradiologie KW - Experimentelle Bildgebung KW - Magnetic Particle Imaging KW - Traveling Wave Magnetic Particle Imaging KW - Interventionelle Radiologie KW - MPI KW - experimental imaging KW - magnetic particle imaging KW - traveling wave magnetic particle imaging KW - interventional radiology KW - Transluminale Angioplastie KW - MPI Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-352517 ER - TY - JOUR A1 - Diessner, Joachim A1 - Anders, Laura A1 - Herbert, Saskia A1 - Kiesel, Matthias A1 - Bley, Thorsten A1 - Schlaiss, Tanja A1 - Sauer, Stephanie A1 - Wöckel, Achim A1 - Bartmann, Catharina T1 - Evaluation of different imaging modalities for axillary lymph node staging in breast cancer patients to provide a personalized and optimized therapy algorithm JF - Journal of Cancer Research and Clinical Oncology N2 - Purpose The reliable detection of tumor-infiltrated axillary lymph nodes for breast cancer [BC] patients plays a decisive role in further therapy. We aimed to find out whether cross-sectional imaging techniques could improve sensitivity for pretherapeutic axillary staging in nodal-positive BC patients compared to conventional imaging such as mammography and sonography. Methods Data for breast cancer patients with tumor-infiltrated axillary lymph nodes having received surgery between 2014 and 2020 were included in this study. All examinations (sonography, mammography, computed tomography [CT] and magnetic resonance imaging [MRI]) were interpreted by board-certified specialists in radiology. The sensitivity of different imaging modalities was calculated, and binary logistic regression analyses were performed to detect variables influencing the detection of positive lymph nodes. Results All included 382 breast cancer patients had received conventional imaging, while 52.61% of the patients had received cross-sectional imaging. The sensitivity of the combination of all imaging modalities was 68.89%. The combination of MRI and CT showed 63.83% and the combination of sonography and mammography showed 36.11% sensitivity. Conclusion We could demonstrate that cross-sectional imaging can improve the sensitivity of the detection of tumor-infiltrated axillary lymph nodes in breast cancer patients. Only the safe detection of these lymph nodes at the time of diagnosis enables the evaluation of the response to neoadjuvant therapy, thereby allowing access to prognosis and improving new post-neoadjuvant therapies. KW - breast cancer imaging KW - positive nodal status KW - cross-sectional imaging KW - conventional imaging KW - post-neoadjuvant therapies KW - neoadjuvant therapies Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324047 VL - 149 IS - 7 ER - TY - JOUR A1 - Detomas, Mario A1 - Altieri, Barbara A1 - Schlötelburg, Wiebke A1 - Appenzeller, Silke A1 - Schlaffer, Sven A1 - Coras, Roland A1 - Schirbel, Andreas A1 - Wild, Vanessa A1 - Kroiss, Matthias A1 - Sbiera, Silviu A1 - Fassnacht, Martin A1 - Deutschbein, Timo T1 - Case Report: Consecutive Adrenal Cushing’s Syndrome and Cushing’s Disease in a Patient With Somatic CTNNB1, USP8, and NR3C1 Mutations JF - Frontiers in Endocrinology N2 - The occurrence of different subtypes of endogenous Cushing’s syndrome (CS) in single individuals is extremely rare. We here present the case of a female patient who was successfully cured from adrenal CS 4 years before being diagnosed with Cushing’s disease (CD). The patient was diagnosed at the age of 50 with ACTH-independent CS and a left-sided adrenal adenoma, in January 2015. After adrenalectomy and histopathological confirmation of a cortisol-producing adrenocortical adenoma, biochemical hypercortisolism and clinical symptoms significantly improved. However, starting from 2018, the patient again developed signs and symptoms of recurrent CS. Subsequent biochemical and radiological workup suggested the presence of ACTH-dependent CS along with a pituitary microadenoma. The patient underwent successful transsphenoidal adenomectomy, and both postoperative adrenal insufficiency and histopathological workup confirmed the diagnosis of CD. Exome sequencing excluded a causative germline mutation but showed somatic mutations of the β-catenin protein gene (CTNNB1) in the adrenal adenoma, and of both the ubiquitin specific peptidase 8 (USP8) and the glucocorticoid receptor (NR3C1) genes in the pituitary adenoma. In conclusion, our case illustrates that both ACTH-independent and ACTH-dependent CS may develop in a single individual even without evidence for a common genetic background. KW - Cushing’s syndrome KW - Cushing’s disease KW - hypercortisolism KW - glucocorticoid excess KW - USP8 KW - CTNNB1 KW - NR3C1 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-244596 SN - 1664-2392 VL - 12 ER - TY - JOUR A1 - Conrads, Nora A1 - Grunz, Jan-Peter A1 - Huflage, Henner A1 - Luetkens, Karsten Sebastian A1 - Feldle, Philipp A1 - Grunz, Katharina A1 - Köhler, Stefan A1 - Westermaier, Thomas T1 - Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine JF - Archives of Orthopaedic and Trauma Surgery N2 - Introduction In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. Materials and methods Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. Results Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. Conclusions Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required. KW - pedicle screws KW - vertebral pedicles KW - fluoroscopy KW - neuronavigation KW - spine Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324966 VL - 143 IS - 6 ER - TY - THES A1 - Cao, Victoria Xinghui T1 - Stichkanalembolisation nach perkutaner transhepatischer Cholangiodrainage mittels Gelatineschwamm: Eine retrospektive Analyse T1 - Catheter tract embolization after percutaneous biliary drainage using gelatin sponge: a retrospective analysis N2 - Durch die Anlage einer perkutanen transhepatischen Cholangiodrainage (PTCD), im Rahmen benigner und maligner biliärer Obstruktionen, wird eine Kommunikation zwischen Hautoberfläche, Peritoneum und dem biliären System geschaffen. Insbesondere nach Entfernung der PTCD besteht das Risiko einer Galleleckage, einer Blutung, einer biliokutanen Fistel oder einer lokalen Peritonitis, mit durchaus schwerwiegenden Konsequenzen. Die Embolisation dieses Stichkanals nach Entfernung der Drainage mittels Gelatineschwamm (Gelfoam) stellt eine einfache und effektive Lösung dar diese Komplikationen zu reduzieren und zu verhindern. Ziel dieser Studie war es, die Effektivität der Stichkanalembolisation mittels Gelatineschwamm nach PTCD retrospektiv zu evaluieren. N2 - Applying percutaneous biliary drainage (PTBD) in the context of benign and malignant biliary obstructions, communication between the skin surface, peritoneum and the biliary system is created. Particularly after removal of the PTBD, there is a risk of bile leakage, bleeding, a bilio-cutaneous fistula or local peritonitis, with serious consequences. Transhepatic catheter tract embolization after removal of the drainage using gelatin sponge (Gelfoam) is a simple and effective method to reduce and prevent these complications. The aim of this study was to retrospectively evaluate the feasibility and safety of tract embolization after PTBD using gelatin sponge. KW - Embolisation KW - Stichkanalembolisation KW - Perkutane transhepatische Cholangiodrainage KW - Interventionelle Radiologie KW - Galle KW - Gelatineschwamm KW - tract embolization KW - percutaneous biliary drainage KW - Interventional radiology KW - Biliary KW - gelatin sponge Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-210855 ER - TY - THES A1 - Bürckstümmer, Ruth T1 - Quantitative 31P-MR-spektroskopische Untersuchung globaler Herzerkrankungen unterschiedlicher Genese - Verlaufsbeobachtung nach Aortenklappenersatz und unter Therapie bei Dilatativer Kardiomyopathie T1 - Quantitative 31P-NMR Spectroscopy in Global Heart Diseases of different genesis - Observations after Aortic Valve Replacement and during Therapy in Dilated Cardiomyopathy N2 - Die Arbeit zeigt bei verschiedenen Patientengruppen, dass mit Hilfe der quantitativen 31P-MR-Spektroskopie der Energiemetabolismus des Myokards beurteilt werden kann. Mit der gewählten Methode SLOOP ist nun auch eine Bestimmung der absoluten Konzentration der energiereichen Phosphate PCr und ATP möglich; im Gegensatz dazu wurde bisher nur das Verhältnis von PCr/ATP bestimmt. Die Beobachtungen bei Patienten mit Aortenklappenfehlern zeigten vor und nach Aortenklappenersatz Veränderungen, ebenso wurden bei Patienten mit Dilatativer Kardiomyopathie nach Einsatz von ß-Blockern bzw. nach Beginn regelmäßiger körperlicher Aktivität Verbessserungen des Energiestoffwechsels beobachet. N2 - The Study shows in different patient groups, that the high energy metabolism of myocardial tissue can be judged by 31P-NMR spectroscopy. With the chosen method SLOOP it is possible to do a quantitative determination of the high energy phosphates PCrand ATP unlike determining the ratio of PCr/ATP. The observations in patients with aortic valve diseases showed changes before and after valve replacement, in patients with dilated cardiomyopathy improvements of the energy metabolism could be observed as well after beginning of a ß-blocker therapy and after exercise. KW - Quantitative 31P-MR- Spektroskopie KW - Herzerkrankung KW - Aortenklappenersatz KW - DCM KW - 31P-MR-Spectroscopy KW - Heartdisease KW - Aortic Valve Replacement KW - DCM Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8976 ER - TY - THES A1 - Böck, Lena T1 - Evaluation der präoperativen Ausdehnungsbestimmung ductaler Carcinomata in situ mittels hochauflösender 3-Tesla MR-Mammographie T1 - Evaluation of the Extension of ductal Carcinoma in situ with high resolution 3-Tesla MR mammography N2 - Zusammenfassend lässt sich sagen, dass auch in dieser Studie die MRT bewiesen hat, dass sie eine Diagnostik ist, die aufgrund ihrer vielen Vorteile (röntgenstrahlenfrei, schmerzfrei, hochauflösende Diagnostik) der konventionellen Mammographie überlegen ist. Im Vergleich mit anderen diagnostischen Möglichkeiten, weist die MRT die höchsten Sensitivitäten auf. Viele falsch positive Befunde könnten so vermieden werden und unnötige Biopsien umgangen werden. Die MRT zeigte in dieser Studie eine Sensitivität von 78%, für reine DCIS 76%. Die in der präoperativen MR-Diagnostik gemessenen Größen korrelierten statistisch signifikant mit der histologisch bestimmten Größe für alle Gruppen (reines DCIS, begleitendes DCIS, mikroinvasives DCIS) zusammen genommen (c=0,378; p<0,01) sowie für reine DCIS (c=0,403; p<0,05). Desweiteren korrelierten die Größen statistisch signifikant für high-grade DCIS (c=0,493; p<0,05) und für Nekrosen positive DCIS (c=0,556; p<0,01). Hier ließen sich die Tumorgrößen verlässlich vorhersagen. In der Auswertung der Signalintensitäts-Zeit-Kurven zeigten sich signifikante Unterschiede zwischen den Gruppen hinsichtlich der initialen (p<0,05) und postinitialen Phase (p<0,01). So lässt sich anhand der KM-Kinetik eine Aussage über die Malignität treffen. Ein reines DCIS zeigte typischerweise eine initiale Phase mit einem KM-Anstieg von 50-100% oder >100%, gefolgt von einer Plateau-Phase. Ein invasives Carcinom begleitendes DCIS zeichnete sich durch einen raschen Anstieg >100% gefolgt von einem „wash-out“ und einem inhomogenen, unbegrenzten Anreicherungsverhalten aus. Mikrovinvasive DCIS zeigten ähnlich den reinen DCIS einen initialen Anstieg von 50-100% sowie eine folgende Plateau-Phase. Keinen statistisch signifikanten Einfluss hatte die präoperative Größenbestimmung auf das operativen Verfahren (BET vs. Ablatio). Trotz der präoperativen MRT waren zu 29,6 % Nachresektionen - davon ca. die Hälfte (14,1%) als sekundäre Ablatio - nötig. Mit der MRT ließen sich grundsätzlich verlässliche präoperative Vorhersagen hinsichtlich Größe und Malignität treffen. Signalintensitäts-Zeit-Kurven und höhere Feldstärken, wie die 3T-MRT, könnten sehr hilfreich sein und die Sensitivität und Spezifität verbessern. Warum trotz allem noch so viele Nachresektionen nötig sind, gilt es in folgenden Studien zu untersuchen. N2 - Evaluation of the Extension of ductal Carcinoma in situ with high resolution 3-Tesla MR mammography KW - DCIS KW - MRT KW - duktal KW - Tesla KW - evaluation Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-169153 ER - TY - THES A1 - Bärwolff, Jennifer T1 - Prognostische Marker im MRT bei diffus intrinsischen Ponsgliomen im Kindesalter T1 - Diffuse intrinsic brainstem glioma in children – prognostic marker on MRI N2 - Das DIPG ist eine für die Kindheit recht spezifische Neoplasie und geht aufgrund seiner Lage im Hirnstamm mit diffusen Ausbreitungsmuster, sowie fehlendem Therapieansprechen mit einer sehr schlechten Prognose einher. 90% der betroffenen Kinder versterben innerhalb der ersten beiden Jahre nach Diagnosestellung. Ziel dieser Arbeit war es herauszufinden ob es bildgebende oder epidemiologische Merkmale gibt, die einen Einfluss auf die Überlebenszeiten zeigen und somit als prognostische Marker genutzt werden können. Die Daten der 253 Studienteilnehmer mit neudiagnostizierten DIPG stammen aus der HIT-HGG-2007-Studie, sowie den 4 Vorgängerstudien HIT-GBM-A-D über einen Untersuchungszeitraum von 1998 - 2012. Alle Erst-MRTs und alle 3-monatige follow-up-Untersuchungen wurden statistisch ausgewertet und mit Hilfe von Kaplan-Meier-Kurven Überlebenswahrscheinlichkeiten für das OS und EFS bestimmt, sowie anschließendem Gruppenvergleich im Log- Rank-Test. Als prognostisch günstig erwiesen sich ein Erkrankungsalter bei Diagnosestellung unter 3 Jahren, sowie eine Therapie nach SKK-Schema. Auch eine fehlende Kontrastmittelaufnahme bei Diagnosestellung und eine große Tumorfläche zeigten bessere Überlebenszeiten. Dagegen hatten weder das Geschlecht, noch die Histologie, noch eine max. Flächen- oder Volumenreduktion Einfluss auf die Überlebenszeiten der betroffenen Kinder. N2 - Brainstem tumors are the most common solid neoplasm in childhood. Especially diffuse intrinsic brainstem gliomas occure diffusely in the pons. Subsequently they are difficult to treat and characterized by a dismal prognosis. More than 90% of children die within 2 years of diagnosis. The aim of this retrospective study was to find any predictive imaging or epidemiological features of overall and progression free survival, which could be used as prognostic markers. Data were analyzed from 253 children with newly diagnosed pontine glioma registered in HIT-GBM database, including the prospective multi-center studies HIT- GBM A-D and HIT-HGG 2007, from 1998-2012. To evaluate prognostic values, we performed a Kaplan-Meier survival analysis (log- rank test) that incorporated all initial MRIs and 3 month-follow-up MRIs. Favorable prognostic factors seemed to be an age younger than 3 years, as well as a therapy according to SKK, a large tumor area and absence of enhancement at baseline. But there was no survival difference between males and females. Neither histological grade, nor a maximum reduced tumor area or volume have shown a prognostic relevance. KW - DIPG KW - diffus intrinsisches Ponsgliom KW - prognostische Marker KW - MRT KW - brainstem glioma KW - prognostic marker on MRI Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-185505 ER -