TY - JOUR A1 - Wieber, Markus A1 - Fetzer-Kremling, Isa A1 - Reith, Hildegard A1 - Burschka, Christian T1 - Synthese und Struktur von Phenyltetra(acetato)stiboran T1 - Synthesis and structure of Phenyltetra(acetato)stiborane N2 - No abstract available KW - Chemie KW - Phenyltetra(acetato)stiborane KW - Synthesis KW - X-Ray Crystal Structure Y1 - 1987 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-47137 ER - TY - JOUR A1 - Wieber, Markus A1 - Lang, Stefan A1 - Rohse, Stefan A1 - Habersack, Ralph A1 - Burschka, Christian T1 - Synthese und Kristallstruktur von Triphenyltelluroniumsulfid T1 - Synthesis and Crystal Structure of Triphenyltelluroniumsulfide N2 - No abstract available KW - Chemie KW - Triphenyltelluroniumsulfide KW - Synthesis KW - NMR Data KW - Crystal Structure KW - Secondary Bonding Y1 - 1994 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-47151 ER - TY - JOUR A1 - Darwish, Hany W. A1 - Attia, Mohamed I. T1 - New spectrofluorimetric methods for determination of melatonin in the presence of N-{2-[1-({3-[2-(acetylamino)ethyl]-5-methoxy-1H-indol-2-yl}methyl)-5-methoxy-1H-indol-3-yl]- ethyl}acetamide: a contaminant in commercial melatonin preparations N2 - Background: Melatonin (MLT) has many health implications, therefore it is of valuable importance to develop specific analytical methods for determination of MLT in the presence of its main contaminant, N-{2-[1-({3-[2-(acetylamino)ethyl]-5-methoxy-1H-indol-2-yl}methyl)-5-methoxy-1H-indol-3-yl]ethyl}acetamide (10). For development of these analytical methods, compound 10 had to be prepared in an adequate amount. Results: Compound 10 was synthesized in six steps starting from 5-methoxyindole-2-carboxylic acid (1). Analytical performance of the proposed spectrofluorimetric methods was statistically validated with respect to linearity, accuracy, precision and specificity. The proposed methods were successfully applied for the assay of MLT in laboratory prepared mixtures containing up to 60 % of compound 10 and in commercial MLT tablets with recoveries not less than 99.00 %. No interference was observed from common pharmaceutical additives and the results were favorably compared with those obtained by a reference method. Conclusions: This work describes simple, sensitive, and reliable second derivative spectrofluorimetric method in addition to two multivariate calibration methods, principal component regression (PCR) and partial least square (PLS), for the determination of MLT in the presence of compound 10. KW - Chemie KW - Melatonin KW - Contaminants KW - Synthesis KW - Spectrofluorimetry KW - Commercial preparations Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-78234 ER -