TY - THES A1 - Schillinger, Judith Hanna T1 - Schmerzen und ihre Therapie in der Hüftendoprothetik. Eine retrospektive Studie zum Vergleich des minimal-invasiven direkt anterioren mit dem transglutealen Zugang nach Bauer T1 - Pain and its therapy in hip arthroplasty. A retrospective study comparing the minimally invasive direct anterior approach with the transgluteal approach according to Bauer N2 - Hintergrund: Die Entwicklung minimal-invasiver gewebeschonender Zugangswege in der Hüftendoprothetik ist im Allgemeinen mit einer schnelleren Rehabilitation, einer Verringerung der postoperativen Schmerzen und einem erhöhten Patientenkomfort verbunden. Das Ziel dieser Studie war es, einen anterioren minimal-invasiven mit einem transglutealen lateralen Zugangsweg für Hüftgelenksersatzoperationen in Bezug auf postoperatives Schmerzniveau, den Schmerzmittelgebrauch, die Länge des Krankenhausaufenthalts und die Zeit bis zum Erreichen eines definierten physiotherapeutischen Therapiezieles zu vergleichen. Methoden: In dieser retrospektiven Kohortenstudie untersuchten wir 200 Patienten, die sich einer Hüftendoprothesenimplantation unterzogen. Gruppe I (n = 100) erhielt einen minimal-invasiven anterioren Hüftzugang (modifiziert nach Smith-Peterson), Gruppe II (n = 100) erhielt einen lateralen transglutealen Zugang (nach Bauer). Die Untersuchungsziele waren der Schmerz in Ruhe und während der Physiotherapie, der Schmerzmittelgebrauch, die Länge des stationären Aufenthaltes sowie die Zeitdauer bis zum Erreichen des physiotherapeutischen Therapiezieles. Ergebnisse: Die Patienten der Gruppe I konsumierten weniger Schmerzmedikamente (19,6 ± 6,9 mg Piritramid gegenüber 23,6 ± 11,3 mg; p = 0,005) und hatten in der frühen postoperativen Phase weniger Schmerzen (Operationstag: VAS 1,3 ± 1 gegenüber 2,3 ± 1,3, p = 0,0001, erster postoperativer Tag: VAS 0,41 ± 0,8 vs. 0,66 ± 1,1, p = 0,036). Die Zeit bis zum Erreichen des definierten Therapiezieles (6,4 ± 2 Tage gegenüber 7,4 ± 2,1 Tagen; p = 0,001) und die Dauer des Krankenhausaufenthalts waren kürzer (10,2 ± 1,9 Tage gegenüber 13,4 ± 1,6 Tagen; p = 0,0001) für Gruppe I. Die Schmerzen während der Physiotherapie waren jedoch am dritten und sechsten bis neunten Tag nach der Operation im Vergleich zu Gruppe II höher (p = 0,001–0,013). Schlussfolgerung: Die Implantation einer Hüftprothese über einen minimal-invasiven anterioren Zugang führt in der direkt postoperativen Phase zu einer Reduktion des Schmerzniveaus und des Schmerzmittelgebrauchs. Zusätzlich werden das Erreichen des physiotherapeutischen Therapiezieles und die Länge des stationären Aufenthaltes positiv beeinflusst. Den höheren Schmerzen während der Physiotherapie könnte durch eine Reduktion der erlaubten Gewichtsbelastung in der frühen postoperativen Phase entgegengewirkt werden. N2 - Purpose: The development of minimal-incision techniques for total hip replacement with preservation of soft tissue is generally associated with faster rehabilitation, reduction of postoperative pain and increased patient comfort. The aim of this study was to compare a minimal-incision anterior approach with a transgluteal lateral technique for hip replacement surgery with respect to postoperative pain, consumption of rescue medication, length of hospital stay and time to reach a defined range of motion. Methods: In this retrospective cohort study we investigated 100 patients with a minimal-incision anterior approach (group I) and 100 patients with a transgluteal lateral approach (group II) retrospectively undergoing unilateral hip replacement. The study variables were pain at rest and during physiotherapy, amount of rescue medication, the time to reach a defined flexion and time in hospital. Results: The patients of group I consumed less rescue medication (19.6 ± 6.9 mg vs. 23.6 ± 11.3 mg;  p = 0.005) and experienced less pain on the day of surgery (1.3 ± 1 vs. 2.3 ± 1.3, p = 0.0001) and the first postoperative day (0.41 ± 0.8 vs. 0.66 ± 1.1, p = 0.036). The time to reach the defined range of motion (6.4 ± 2 days vs. 7.4 ± 2.1 days; p = 0.001) and the length of hospital stay were shorter (10.2 ± 1.9 days vs. 13.4 ± 1.6 days; p = 0.0001) for group I. However, pain during physiotherapy was higher on the third and sixth through ninth days after surgery in comparison to group II (p = 0.001–0.013). Conclusion: The implantation of a hip prosthesis through a minimal-incision anterior approach is successful in reducing postoperative pain and consumption of pain medication. Time to recovery and length of hospital stay are also influenced positively. Pain increases during physiotherapy, and may be mitigated by adopting limited weight bearing during the early postoperative period. KW - minimal-invasiv KW - vorderer Zugang KW - Hüftendoprothetik KW - Postoperativer Schmerz KW - minimally invasiv KW - THA KW - anterior approach KW - total hip arthroplasty KW - postoperative pain KW - minimalinvasive KW - hip KW - arthroplasty Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-225745 ER - TY - THES A1 - Heim, Rebecca Fabiola Natali T1 - Mechanische In-vitro-Materialprüfung von modifizierten, bioaktivierten Knochenzementen auf der Basis von Polymethylmethacrylat T1 - Mechanic in-vitro fatigue-testing of modified bioactivated bone cements based on polymethylmethacrylate N2 - Das Hauptproblem des künstlichen Gelenkersatzes stellt die aseptische Prothesenlockerung dar. Hierbei handelt es sich um ein multifaktoriell bedingtes Geschehen, das auf ein gestörtes Zusammenspiel von biologischen und mechanischen Faktoren zurückzuführen ist. Im Rahmen dieser Arbeit wurden fünf modifizierte, bioaktivierte Knochenzemente bezüglich ihrer Verbundfestigkeit mit Edelstahl und ihrer Hydrolysestabilität untersucht. Ein gemeinsamer Bestandteil aller fünf Modifikationen stellt Hydroxyethylmethacrylat-Phosphat dar. Die Verbundfestigkeit der Zemente wurde anhand unterschiedlicher Anwendungs- bzw Metallvorbehandlungsvoraussetzungen im axialen Zugtest vor und nach künstlicher Alterung ermittelt. Unabhängig von der Vorbehandlung bzw. Anwendungsmodifikation zeigte der ausschließlich mit HEMA-P modifizierte Zement und der Referenzzement annähernd gleiche Zugfestigkeitswerte während die Zementmodifikation mit HEMA-P und zusätzlich Natriumcarbonat und Calciumchlorid deutlich niedrigere Zugfestigkeiten erreichte. Diese Modifikation konnte zudem, bis auf die Testreihe mit erfolgter Silikatisierung und silanisiertem Monomer, dem künstlichen Alterungsprozess nicht standhalten, was die Hydrolysestabilität dieser Modifikation in Frage stellt. Die höchsten Zugfestigkeitswerte nach dem Alterungsprozess konnten, unabhängig von der Zementmodifikation, bei der Testreihe mit erfolgter Silikatisierung und einem mit Silanhaftvermittler angereicherten Monomer festgestellt werden. Die Zemente wurden auf ihre Druckfestigkeit und im vereinfachten dynamischen Hüftprüfstandversuch im flüssigen Milieu getestet. Die Tatsache, dass sich bei allen Zementmodifikationen relativ wenig Spalten am Zement-Metall-Interface nachweisen ließen, spricht für eine gesteigerte Hydrolysebeständigkeit unter dynamischer Belastung. Die ermittelten Druckfestigkeiten liegen im Bereich von 83,85 MPa für PM 10, 89,66 MPa für PM 11 und 82 MPa für SPM 10 was den Anforderungen an Knochenzemente gerecht wird. Diese sollten gemäß ISO 5833 eine Druckfestigkeit von über 70 MPa aufweisen. Um eine detaillierte Aussage über die mechanischen Eigenschaften dieser Zementmodifikationen treffen zu können bedarf es weiterer Materialprüfungen N2 - The main problem in artificial joint replacement is the aseptic prosthesis loosening. The causes are multifactorially conditioned since both biological and mechanical factors are playing a major role. To generate bioactive PMMA surfaces directly at the site of implantation an amphiphilic molecule phosphorylated 2‐hydroxyethylmethacrylate (HEMA‐P) had already been added to commercial bone cements.One bone cement modification had also been enriched with calcium and carbonate salts. The first part of this study was to compare two modified bio‐activated bone cements concerning their tensile strength and their hydrolytic stability to standard commercial bone cement. The Bone Cements were tested regarding different usage and pre‐treatment of the metal used before and after 15 days of storage at 70 degrees Celsius in PBS. Only the bone cement modified with HEMA‐P reached about the same results as the common bone cement. Whereas the modification with additional calcium and carbonate salts showed not only a significantly lower tensile strength but also hydrolytic instability compared to the common bone cement. The best results after the artificial aging process could be proven after silicate coating of the metal and the enrichment of the monomer with a silane coupling agent. The second part of the study was designed to proof that modified bone cements meet the common ISO standards regarding their compressive and fatigue strengths and their hydrolytic stability. All the modified samples met the common ISO standard figures for compressive strength of more than 70 MPa. Furthermore the fact that all modifications have shown little signs of fatigue and minor cracks at the cement‐metal interface in testing indicates the conclusion that the hydrolytic stability is given. However, to describe the entire range of mechanical characteristics, more experiments would have to be carried out. KW - Aseptische Lockerung KW - Druckfestigkeit KW - Zugfestigkeit KW - Knochenzement KW - Hüftgelenkprothese KW - Dauerschwingfestigkeit KW - aseptic prosthesis loosening KW - tensile strength KW - bone cement KW - total hip arthroplasty Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-81170 ER - TY - THES A1 - Kaufmann, Katharina T1 - Aktivitätsverlauf, Funktionsstatus und Lebensqualität nach minimal-invasivem anteriorem Zugang bei Hüfttotalendoprothesen T1 - Activity, functionality outcome and health-related quality of life using a minimally invasive anterior approach for total hip arthroplasty N2 - Die Studie untersucht Aktivitätsverlauf, Funktionsstatus und Lebensqualität nach minimal-invasivem anteriorem Zugang bei Hüfttotalendoprothesen (präoperativ bis sechs Wochen postoperativ) mit Hilfe der Fragebögen PHQ-D, XSMFA-D, SF-36, HHS, Täglicher Würzburger Aktivitätsfragebogen, Arzt- u. Patientenbogen Hüfte. N2 - This clinical study investigates activity, functionality outcome and health-related quality of life using a minimally invasive anterior approach for total hip arthroplasty (preoperatively up to six weeks postoperatively) using questionnaires inter alia PHQ-D, XSMFA-D, SF-36, HHS, Daily activity questionnaire (DAQ). KW - Endoprothese KW - Hüftgelenk KW - Klinisches Experiment KW - Aktivität KW - Funktion KW - Lebensqualität KW - minimal-invasiv KW - anteriorer Zugang KW - activity KW - functionality outcome KW - health-related quality of life KW - minimally invasive anterior approach KW - total hip arthroplasty Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-81583 ER - TY - THES A1 - Bockholt, Martin T1 - 9-11 Jahres Ergebnisse nach zementierter Titanschaft-Prothese (Müller-Geradschaftprothese) T1 - 9 -11 years results of cemented titanium Mueller straight stem in total hip replacement N2 - In den letzten Jahrzehnten ist die Anzahl der degenerativen Gelenkerkrankungen wie die Coxarthrose und somit die Zahl der zu implantierenden Hüfttotalendoprothesen stark gestiegen. Ziel der vorliegenden Arbeit ist es, langfristige Ergebnisse zementierter Titanschaftprothesen in Bezug auf aseptische Lockerungen zu ermitteln. Von den in der Orthopädischen Universitätsklinik Würzburg implantierten Hüfttotalendoprothesen von Januar 1990 bis März 1992 konnten nach durchschnittlich 9 Jahren 110 Hüfttotalendoprothesen klinisch und radiologisch nachuntersucht werden. Zum Zeitpunkt der Kontrolluntersuchung hatten die Patienten ein mittleres Alter von 76 Jahren. In allen Fällen wurden Müller-Geradschaftprothesen mit einer Ti-6A1-7Nb-Legierung in matter Oberfläche, Biolox®-Keramik-Köpfe sowie Knochenzement Palacos-® verwendet. Es wurde bei 4 Hüft-TEPs wegen aseptischer Lockerung ein Prothesenwechsel durchgeführt. Das nachuntersuchte Patientengut wurde in 3 Gruppen eingeteilt. Gruppe A rekrutierte sich aus denjenigen Patienten, bei denen keine radiologischen Lockerungszeichen erkennbar waren. Die Patienten mit mehr als einem Lysesaum jedoch mit festem Sitz der Schaftprothese im Vergleich zu den postoperativen Röntgenbildern wurden der Gruppe B zugeordnet. Letztendlich bildeten die Patienten mit ausgeprägten Lockerungszeichen bzw. vollständig gelockerte Prothesen die Gruppe C. Der Harris-Hip-Score der Gruppe A mit 85 ( 13) Punkten und der Gruppe B mit 86 ( 14) Punkten zeigte gute Ergebnisse. Der Harris-Score lag in der Gruppe C bei 76 (± 5) Punkten und erreichte somit ein mäßiges Ergebnis. Im Vergleich zu den Gruppen A und B erwies sich diese Punktezahl als signifikant schlechter. Die Patienten mit ausgeprägten Lockerungszeichen waren signifikant jünger (im Mittel 6 Jahre) als die der Gruppe ohne Lockerungssäume. Ebenfalls fanden wir einen signifikanten Unterschied im Bezug auf das Körpergewicht, Körpergewicht im Verhältnis zu zementierter Schaftoberfläche und Harris-Score (88 vs. 75 kg; 1,5 vs. 1,0 kg/cm; 76 vs. 85). Für Geschlecht, Schaftgröße, Schaftart, Aktivität, heterotope Ossifikationen und Body-Maß-Index traf dies nicht zu. Unter Berücksichtigung der erhobenen Daten (Harris-Hüft-Score und Quotient des Körpergewichts zur zementierten Schaftoberfläche) sollte eine möglichst große Prothese implantiert werden, um das Körpergewicht auf eine große Schaftoberfläche zu verteilen. Insgesamt hat sich die zementierte Müller-Geradschaftprothese aus Titanlegierung bewährt, so dass sie für die Behandlung von Nickelallergiker zu empfehlen ist. N2 - The purpose of this study was to obtain 9-11years results after total hip arthroplasty (THA) with cemented titanium stems (Mueller-Straight-Stem). 91 patients with a total of 110 THA were examined clinically and radiologically after an average follow-up of 9,5 years. Revisions for aseptic loosening were carried out in 4 cases (4%). Subsidence or varus position could only be observed in one of these cases. Radiolucent lines (RLL) were found in 37 cases, mainly located around the proximal zones of the stem (zone 1, 7, 8 and 14). The clinical results in the Harris score were good or excellent in 78% and satisfactory in 20% of the cases. The body weight was significantly higher (88 kg; d=5.4) in the 4 patients with aseptic loosening, compared to patients without RLL (75kg; d=15), especially the ratio body weight to surface of the stem showed a significant difference (1.5 kg/cm2 versus 1 kg/cm2; p<0.05). No significant differences were found in other factors, including sex, size or type of stem, Harris-score, heterotopic ossification or body-mass index. Good long-term results can be achieved with cemented titanium stem implants. In conclusion, this titanium implant may be recommended for patients with hypersensitivity against Chrome, Cobalt and Nickel. Implanting the biggest possible stem seems to be most beneficial. KW - Aseptische Lockerung KW - Hüftgelenk KW - Prothese KW - zementierte Hüfttotalendoprothesen KW - radiologische Lysesäume KW - Körpergewicht im Verhältnis zu zementierter Schaftoberfläche KW - total hip arthroplasty KW - radiolucent lines KW - aseptic loosening KW - ratio body weight to surface of the stem Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-37635 ER -