TY - THES A1 - Münsterer, Sascha Ottmar T1 - Prognostische Wertigkeit der Herzfrequenz in Abhängigkeit von implantierten Devices bei akuter Herzinsuffizienz: Ergebnisse des prospektiven AHF-Registers Würzburg T1 - Prognostic value of heart rate depending on cardiovascular implantable electronic devices in acute heart failure: results from the prospective AHF-Register Würzburg N2 - Aims This study investigated, whether an activated R-mode, a surrogate of chronotropic incompetence in patients carrying a cardiovascular implantable electronic device (CIED), is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). Methods and Results Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and follows patients admitted for AHF were studied. We compared CIED carriers with R-mode stimulation (n=37) to CIED carriers not in R-mode (n=64) and patients without CIEDs (n=511). Mean heart rate on admission was significantly lower in R-mode patients vs. patients with CIED but without R-mode or patients withour CIED. In-hospital mortality was similar across groups, but age- and sex-adjusted 12-month mortality risk was higher in R-mode group. These effects persisted after multivariable adjustment for comorbidity burden. Conclusion In patients admitted for AHF, R-mode stimulation was associated with a significantly increased 12-month mortality risk. Our findings suggest that chronotropic incompetence per se mediates an adverse outcome and may not be adequately treated through accelerometer-based R-mode stimulation during and after an episode of AHF. N2 - Ziele Diese Studie untersuchte, ob ein aktivierter R-Modus, als Surrogat für eine chronotrope Inkompetenz, bei Patienten mit kardialem Device (CIED), mit einer schlechteren Prognose während und nach einer Episode von akuter Herzinsuffizienz (AHF) verbunden ist. Methoden und Ergebnisse 623 Patienten, die an einer laufenden prospektiven Kohortenstudie zur Phänotypisierung von Patienten mit akuter Herzinsuffizienz teilnahmen, wurden untersucht. Wir verglichen CIED-Träger mit R-Modus-Stimulation (n=37) mit CIED-Trägern ohne R-Modus (n=64) und Patienten ohne CIED (n=511). Die durchschnittliche Herzfrequenz bei Aufnahme lag bei Patienten im R-Modus signifikant niedriger als bei Patienten mit CIED, aber ohne R-Modus oder Patienten ohne CIED. Zwar war die Krankenhaussterblichkeit in allen Gruppen ähnlich, jedoch zeigte sich das für Alter und Geschlecht adjustierte 12-Monats-Mortalitätsrisiko in der R-Modus-Gruppe signifikant erhöht. Diese Effekte blieben auch nach multivariabler Adjustierung anhand der Komorbiditäten bestehen. Schlussfolgerung Bei Patienten, die wegen AHF aufgenommen wurden, war die Stimulation im R-Modus mit einem signifikant erhöhten 12-Monats-Mortalitätsrisiko verbunden. Unsere Ergebnisse legen nahe, dass chronotrope Inkompetenz per se mit einer erhöhten Vulnerabilität einhergeht und möglicherweise nicht angemessen durch Beschleunigungs-basierte R-Modus-Stimulation während und nach einer AHF-Episode behandelt wird. KW - akute Herzinsuffizienz KW - Herzschrittmacher KW - Chronotrope Inkompetenz KW - Beschleunigungssensor KW - Herzfrequenz KW - cardiovascular implantable electronic device KW - chronotropic incompetence KW - accelerometer-sensor KW - heart rate KW - acute heart failure KW - cardiac device Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-287755 N1 - Aus datenschutzrechtlichen Gründen wurde der Zugriff auf den Volltext zu diesem Dokument gesperrt. Eine inhaltlich identische neue Version ist erhältlich unter: https://doi.org/10.25972/OPUS-33029 ER - TY - THES A1 - Münsterer, Sascha Ottmar T1 - Prognostische Wertigkeit der Herzfrequenz in Abhängigkeit von implantierten Devices bei akuter Herzinsuffizienz: Ergebnisse des prospektiven AHF-Registers Würzburg T1 - Prognostic value of heart rate depending on cardiovascular implantable electronic devices in acute heart failure: results from the prospective AHF-Register Würzburg N2 - Aims This study investigated, whether an activated R-mode, a surrogate of chronotropic incompetence in patients carrying a cardiovascular implantable electronic device (CIED), is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). Methods and Results Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and follows patients admitted for AHF were studied. We compared CIED carriers with R-mode stimulation (n=37) to CIED carriers not in R-mode (n=64) and patients without CIEDs (n=511). Mean heart rate on admission was significantly lower in R-mode patients vs. patients with CIED but without R-mode or patients withour CIED. In-hospital mortality was similar across groups, but age- and sex-adjusted 12-month mortality risk was higher in R-mode group. These effects persisted after multivariable adjustment for comorbidity burden. Conclusion In patients admitted for AHF, R-mode stimulation was associated with a significantly increased 12-month mortality risk. Our findings suggest that chronotropic incompetence per se mediates an adverse outcome and may not be adequately treated through accelerometer-based R-mode stimulation during and after an episode of AHF. N2 - Ziele Diese Studie untersuchte, ob ein aktivierter R-Modus, als Surrogat für eine chronotrope Inkompetenz, bei Patienten mit kardialem Device (CIED), mit einer schlechteren Prognose während und nach einer Episode von akuter Herzinsuffizienz (AHF) verbunden ist. Methoden und Ergebnisse 623 Patienten, die an einer laufenden prospektiven Kohortenstudie zur Phänotypisierung von Patienten mit akuter Herzinsuffizienz teilnahmen, wurden untersucht. Wir verglichen CIED-Träger mit R-Modus-Stimulation (n=37) mit CIED-Trägern ohne R-Modus (n=64) und Patienten ohne CIED (n=511). Die durchschnittliche Herzfrequenz bei Aufnahme lag bei Patienten im R-Modus signifikant niedriger als bei Patienten mit CIED, aber ohne R-Modus oder Patienten ohne CIED. Zwar war die Krankenhaussterblichkeit in allen Gruppen ähnlich, jedoch zeigte sich das für Alter und Geschlecht adjustierte 12-Monats-Mortalitätsrisiko in der R-Modus-Gruppe signifikant erhöht. Diese Effekte blieben auch nach multivariabler Adjustierung anhand der Komorbiditäten bestehen. Schlussfolgerung Bei Patienten, die wegen AHF aufgenommen wurden, war die Stimulation im R-Modus mit einem signifikant erhöhten 12-Monats-Mortalitätsrisiko verbunden. Unsere Ergebnisse legen nahe, dass chronotrope Inkompetenz per se mit einer erhöhten Vulnerabilität einhergeht und möglicherweise nicht angemessen durch Beschleunigungs-basierte R-Modus-Stimulation während und nach einer AHF-Episode behandelt wird. KW - Herzschrittmacher KW - Beschleunigungssensor KW - Herzfrequenz KW - akute Herzinsuffizienz KW - Chronotrope Inkompetenz KW - cardiovascular implantable electronic device KW - chronotropic incompetence KW - accelerometer-sensor KW - heart rate KW - acute heart failure KW - cardiac device Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-330293 N1 - Dieses Dokument wurde aus Datenschutzgründen - ohne inhaltliche Änderungen - erneut veröffentlicht. Die ursprüngliche Veröffentlichung war am 19.10.2022 ER - TY - JOUR A1 - Morbach, Caroline A1 - Beyersdorf, Niklas A1 - Kerkau, Thomas A1 - Ramos, Gustavo A1 - Sahiti, Floran A1 - Albert, Judith A1 - Jahns, Roland A1 - Ertl, Georg A1 - Angermann, Christiane E. A1 - Frantz, Stefan A1 - Hofmann, Ulrich A1 - Störk, Stefan T1 - Adaptive anti-myocardial immune response following hospitalization for acute heart failure JF - ESC Heart Failure N2 - Aims It has been hypothesized that cardiac decompensation accompanying acute heart failure (AHF) episodes generates a pro-inflammatory environment boosting an adaptive immune response against myocardial antigens, thus contributing to progression of heart failure (HF) and poor prognosis. We assessed the prevalence of anti-myocardial autoantibodies (AMyA) as biomarkers reflecting adaptive immune responses in patients admitted to the hospital for AHF, followed the change in AMyA titres for 6 months after discharge, and evaluated their prognostic utility. Methods and results AMyA were determined in n = 47 patients, median age 71 (quartiles 60; 80) years, 23 (49%) female, and 24 (51%) with HF with preserved ejection fraction, from blood collected at baseline (time point of hospitalization) and at 6 month follow-up (visit F6). Patients were followed for 18 months (visit F18). The prevalence of AMyA increased from baseline (n = 21, 45%) to F6 (n = 36, 77%; P < 0.001). At F6, the prevalence of AMyA was higher in patients with HF with preserved ejection fraction (n = 21, 88%) compared with patients with reduced ejection fraction (n = 14, 61%; P = 0.036). During the subsequent 12 months after F6, that is up to F18, patients with newly developed AMyA at F6 had a higher risk for the combined endpoint of death or rehospitalization for HF (hazard ratio 4.79, 95% confidence interval 1.13–20.21; P = 0.033) compared with patients with persistent or without AMyA at F6. Conclusions Our results support the hypothesis that AHF may induce patterns of adaptive immune responses. More studies in larger populations and well-defined patient subgroups are needed to further clarify the role of the adaptive immune system in HF progression. KW - adaptive immune response KW - acute heart failure KW - anti-myocardial KW - autoantibody KW - inflammation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-258907 VL - 8 IS - 4 ER - TY - THES A1 - Jordan, Franziska T1 - Systematische Bildanalyse des Röntgen-Thorax bei Patienten mit akuter Herzinsuffizienz. Ergebnisse des AHF-Registers Würzburg T1 - Systematic image analysis of chest x-ray in patients with acute heart failure. Results of the AHF-Register Würzburg N2 - Im Zuge der Erstdiagnostik einer Krankenhausaufnahme bei akuter Herzinsuffizienz ist die Röntgen-Thorax-Untersuchung fester Bestandteil. Ziel dieser Arbeit war es, ihren klinischen Stellenwert und die Aufnahmequalität systematisch zu untersuchen. In der AHF-Registerstudie wurden alle am Universitätsklinikum Würzburg vorstelligen Patienten mit akuter Herzinsuffizienz konsekutiv registriert und umfassend phänotypisiert. Die Röntgen-Thorax-Befunde wurden systematisch informationsextrahiert, auf Konsistenz überprüft, katalogisiert und klassifiziert. N2 - In the course of the initial diagnosis of acute heart failure is chest x-ray an integral part. The aim of this work was to systematically research the clinical value and the image quality. All patients, who presented to the Würzburg University Hospital with acute heart failure, were consecutively registered and extensively phenotyped. The chest x-ray findings were systematically extracted, checked for consistency, cataloged and classified. KW - AHF KW - acute heart failure KW - akute Herzinsuffizienz KW - Röntgen-Thorax KW - chest-x-ray Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-243324 ER - TY - JOUR A1 - Albert, Judith A1 - Lezius, Susanne A1 - Störk, Stefan A1 - Morbach, Caroline A1 - Güder, Gülmisal A1 - Frantz, Stefan A1 - Wegscheider, Karl A1 - Ertl, Georg A1 - Angermann, Christiane E. T1 - Trajectories of Left Ventricular Ejection Fraction After Acute Decompensation for Systolic Heart Failure: Concomitant Echocardiographic and Systemic Changes, Predictors, and Impact on Clinical Outcomes JF - Journal of the American Heart Association N2 - Prospective longitudinal follow‐up of left ventricular ejection fraction (LVEF) trajectories after acute cardiac decompensation of heart failure is lacking. We investigated changes in LVEF and covariates at 6‐months' follow‐up in patients with a predischarge LVEF ≤40%, and determined predictors and prognostic implications of LVEF changes through 18‐months' follow‐up. Methods and Results Interdisciplinary Network Heart Failure program participants (n=633) were categorized into subgroups based on LVEF at 6‐months' follow‐up: normalized LVEF (>50%; heart failure with normalized ejection fraction, n=147); midrange LVEF (41%–50%; heart failure with midrange ejection fraction, n=195), or persistently reduced LVEF (≤40%; heart failure with persistently reduced LVEF , n=291). All received guideline‐directed medical therapies. At 6‐months' follow‐up, compared with patients with heart failure with persistently reduced LVEF, heart failure with normalized LVEF or heart failure with midrange LVEF subgroups showed greater reductions in LV end‐diastolic/end‐systolic diameters (both P<0.001), and left atrial systolic diameter (P=0.002), more increased septal/posterior end‐diastolic wall‐thickness (both P<0.001), and significantly greater improvement in diastolic function, biomarkers, symptoms, and health status. Heart failure duration <1 year, female sex, higher predischarge blood pressure, and baseline LVEF were independent predictors of LVEF improvement. Mortality and event‐free survival rates were lower in patients with heart failure with normalized LVEF (P=0.002). Overall, LVEF increased further at 18‐months' follow‐up (P<0.001), while LV end‐diastolic diameter decreased (P=0.048). However, LVEF worsened (P=0.002) and LV end‐diastolic diameter increased (P=0.047) in patients with heart failure with normalized LVEF hospitalized between 6‐months' follow‐up and 18‐months' follow‐up. Conclusions Six‐month survivors of acute cardiac decompensation for systolic heart failure showed variable LVEF trajectories, with >50% showing improvements by ≥1 LVEF category. LVEF changes correlated with various parameters, suggesting multilevel reverse remodeling, were predictable from several baseline characteristics, and were associated with clinical outcomes at 18‐months' follow‐up. Repeat hospitalizations were associated with attenuation of reverse remodeling." KW - acute heart failure KW - left ventricular ejection fraction KW - morbidity KW - mortality KW - natriuretic peptide KW - recovery Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230210 VL - 10 ER -