TY - JOUR A1 - Heilig, Philipp A1 - Faerber, Lars-Christopher A1 - Paul, Mila M. A1 - Kupczyk, Eva A1 - Meffert, Rainer H. A1 - Jordan, Martin C. A1 - Hoelscher-Doht, Stefanie T1 - Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions JF - Scientific Reports N2 - Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required. KW - head depression fractures KW - osteosynthesis KW - arthritis Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-299782 VL - 12 IS - 1 ER - TY - THES A1 - Sönmez, Cagla T1 - Die palmare Rahmenplatte zur Versorgung instabiler distaler Radiusfrakturen: Behandlungsergebnisse nach operativer Versorgung mit der Aptus 2,5 mm Rahmenplatte – Versorgungszeitraum 2009 bis 2011 - T1 - The palmar frame plate for the treatment of unstable distal radius fractures: Outcome after surgical management by using the Aptus 2,5 mm frame plate - Supply period 2009 - 2011 N2 - Ziel/Hintergrund: Die Behandlung der distalen Radiusfraktur machte mit der Zeit eine zunehmende Entwicklung, sodass heute eine Vielzahl von verschiedenen Behandlungsverfahren beschrieben wurden. Dabei befasst sich die vorliegende retrospektive Studie vor allem mit der objektiven, subjektiven, funktionellen und radiologischen Bewertung des Behandlungsergebnisses beim Einsatz der palmaren winkelstabilen Aptus 2,5 mm Rahmenplatte der Firma Medartis. Patienten und Methoden: Es wurden 87 Patienten mit 88 distalen Radiusfrakturen im untersuchten Zeitraum vom 01.01.2009 bis 31.12.2011 mit der palmaren winkelstabilen Aptus 2,5mm Rahmenplatte der Firma Medartis in die Studie aufgenommen. Alle Frakturen wurden nach AO klassifiziert. Während der Nachuntersuchung wurde die Patientenanamnese, der Unfallhergang, das funktionelle Outcome im Sinne der Kraft und der Bewegung am Handgelenk und die radiologischen Parameter erhoben. Eine Einordnung in den Gartland und Werley Score, eine Erhebung des subjektiven Wohlempfindens mittels DASH-Score sowie die Einteilung in die Soong Klassifikation erfolgte ebenfalls. Ergebnis: Die durchschnittliche Follow Up Zeit lag bei 57±10,9 Monaten. Das Durchschnittsalter der Patienten lag bei 58±17,2 Jahren. Es wurden zehn A2, 21 A3, eine B1, zwei B2, eine B3, sieben C1, 18 C2 und 28 C3 Frakturen erfasst. Das Ergebnis der radiologischen Untersuchung zeigt, dass alle präoperativ gemessenen Parameter höchstsignifikante Unterschiede zu postoperativen Verhältnissen aufwiesen. Nach radiologischer Sicht zeigen 68% des Patientenkollektivs ein einwandfreies Ergebnis mit einem Radiusbasiswinkel von 23°, Dorso-Palmaren Kippwinkel von 3°, einer Ulnar Varianz von +1 mm und einer Radiushöhe von 11 mm. Die Patienten erreichten 98% des Bewegungsausmaß verglichen zu ihrer gesunden Gegenseite. Zusammenfassend konnte bei 79% des Patientenkollektivs ein exzellentes bis gutes Kraftergebnis zur intakten Gegenseite ermittelt werden. Mit einem durchschnittlichen Punktewert von 10 erreichten die Patienten ein exzellentes bis gutes Ergebnis im DASH Score. Auch beim Gartland und Werley Score zeigten sich mit einem durchschnittlichen Punktewert von 1, 85% mit einem exzellenten und 15% mit einem guten Ergebnis. Insgesamt wurden 43 Platten in Klasse 0, 37 Implantate in Klasse 1 und lediglich 2 Platten in Klasse 2 nach Soong klassifiziert. Insgesamt ließ sich bei einem Patienten eine frühe Infektion erkennen, welches sich mit oralen Antibiotika gut behandeln ließ. Drei weitere Patienten wiesen eine intraartikuläre Schraubenlage auf. Schlussfolgerung: Bei der Aptus 2,5 mm palmaren winkelstabilen Rahmenplatte von MedArtis handelt es sich um ein sicheres Verfahren in der Behandlung distaler Radiusfrakturen mit sehr guten objektiven, subjektiven, radiologischen und funktionellen Ergebnissen. Die palmare Rahmenplatte kann somit als Standardimplantat empfohlen werden. N2 - Purpose/Background: Distal radius fractures are difficult to manage and so various treatment modalities have been described. This retrospective study presents our experience by using a volar variable-angle locking plate (Aptus 2.5 mm frame plate by Medartis) to evaluate the objective, subjective, functional and radiological outcomes. Patients and Methods: We reviewed 87 patients with mit 88 distal radius fractures that were treated at our institution with volar variableangle locking plates (Aptus 2.5 mm frame plate by Medartis) during 01.01.2009 and 31.12.2011. The fractures were classified according to AO. The follow-up examination included the study of the patient’s history, anamnese about the accident itself, the functional evaluation by measuring the range of motion at the wrist joint as well as the strength and measurment of radiographical parameters. A classification in the Gartland and Werley Score, the DASH score and Soong Classification was also done. Results: The average follow-up time was 57±10,9 months. The mean age of the examined patients was 58±17,2 years. There were ten A2, 21 A3, one B1, two B2 and one B3 fractures, seven C1,18 C2 and 28 C3 fractures. The result of the radiographical measurment shows a significant difference between the pre- and postoperativ parameters. At follow-up the average radial inclination was 23°, the palmar tilt was 3°, ulnar variance was +1 mm and the radial height was 11 mm. 98% of the patients reached an unrestricted wrist motion to their uninjured contralateral side. By testing the strength 79% of the patients reached an good to excellent result to their contralateral side. Patients regained excellent function as represented in an average DASH score of 10 points. According to Gartland and Werley, excellent results were reported in 85% cases, while good results were present in 15% cases. The mean Gartland and Werley score of 1 point was reached. 43 plates were Soong grade 0, 37 plates were Soong grade 1 and 2 plates were Soong grade 2. There was one patient with an early infection that responded to oral antibiotics. And three cases of an intraarticular screw placement. Conclusions: The use of Aptus 2.5 mm frame plate by Medartis in the treatment of distal radius fractures is associated with very good objective, subjective, radiographical and functional outcomes with minimal complications. The palmar plate can be recommended as a standard implant. KW - Distale Radiusfraktur KW - Rahmenplatte KW - palmar KW - distal radius fracture KW - Volar plate fixation KW - locking plate fixation KW - Winkelstabile Platte KW - osteosynthesis KW - DASH Score KW - Gartland and Werley Score Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-214196 ER - TY - THES A1 - Fick, Judith T1 - Wiederherstellung des radialen Bogens nach Osteosynthese von Unterarmschaftfrakturen durch Verriegelungsnagel - Klinische und radiologische Ergebnisse T1 - Reconstruction of the radial bow after interlocking nailing of forearm fractures - Clinical and radiological results N2 - Untersuchung von 35 Patientin nach Osteosynthese von Unterarmschaftfrakturen mittels Verriegelungsnagel zur Wiederherstellung des radialen Bogens. N2 - Examination of 35 patients after interlocking forearm nailing for reconstruction of the radial bow. KW - Osteosynthese KW - Radius KW - Verriegelung KW - osteosynthesis KW - radius KW - interlocking nailing Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-72488 ER - TY - THES A1 - Hipp, Matthias T1 - Modifikation elektrochemisch auf Titan aufgebrachter Calciumhydroxidbeschichtungen durch Fremdmetallionendotierung T1 - Modification of electrochemically deposited calcium hydroxide surface coatings on titanium by different metal ions N2 - Die Verwendung von im Knochen befestigten Implantaten und Endoprothesen aus Titan, sowie Osteosyntheseverfahren mittels Plattenapplikation stellen häufige Routineeingriffe in der Medizin dar. Die Infektion einer Endoprothese oder Osteosyntheseplatte mit Biofilmbildung bedeutet dabei eine schwerwiegende postoperative Komplikation. Ein Schwerpunkt medizinischer Forschung beschäftigt sich aus diesem Grunde mit der Entwicklung antiseptischer Oberflächen. Die vorliegende Arbeit beschreibt die Weiterentwicklung einer in der Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde der Universitätsklinik Würzburg entwickelten elektrochemischen Calciumhydroxidbeschichtung auf Titan. Durch die gezielte Dotierung der Ausgangsschicht mit Silberionen konnte die starke kurzfristige Antisepsis des Calciumhydroxides mit einer wirksamen und langfristigen bakteriziden Wirkung des Silbers kombiniert werden. N2 - The use of bone-fixed implants, endoprosthesis and osteosythesis plates made of titanium are common treatements in medicine. Post-operative infections associated with biofilm-formation are a serious complication in surgery. Therefore, a focus in medical research deals with the developement of antiseptic surface coatings. This study describes the advancement of an electrochemical deposited surface coating made of calcium hydroxide on titanium, developed at “Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde” at University Hospital Würzburg. It was possible to combine the strong short-term antisepsis of calcium hydroxide with an effective long-term bactericide action by silber ions. KW - Calciumhydroxid KW - Hydroxylapatit KW - Beschichtungsanlage KW - Antisepsis KW - Silber KW - Osteosynthese KW - calciumhydroxide KW - surface coating KW - antisepis KW - silver KW - osteosynthesis Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-55114 ER - TY - THES A1 - Gebhard, Christopher T1 - Biomechanischer Stabilitätsvergleich zwei- und dreidimensionaler, winkelstablier Miniimplantate für die Osteosynthese von Mittelhandfrakturen T1 - Biomechanical testing of two and three dimensional miniature locking-plates for the osteosynthesis of metacarpal fractures N2 - 1 Einleitung .1 1.1 Plattenosteosynthese.1 1.1.1 Frakturheilung .1 1.1.2 Geschichte der Plattenosteosynthese .4 1.2 Winkelstabilität .8 1.2.1 Prinzipien winkelstabiler Verbindungen .10 1.3 Anatomie und Biomechanik der Mittelhand .14 1.4 Frakturen der Mittelhand und Finger .17 1.4.1 Epidemiologie .17 1.4.2 Klassifikation der Mittelhandfrakturen .18 1.4.3 Therapie der Mittelhandfrakturen .20 1.4.3.1 Konservative Therapie .21 1.4.3.2 Operative Therapie .23 1.4.3.3 Funktionelle Nachbehandlung .26 1.4.4 Komplikationen .27 1.5 Ziel der Arbeit .29 2 Material und Methoden .31 2.1 Prüfkörper.31 2.2 Geprüfte Implantate .32 2.3 Versuchsvorbereitung .33 2.4 Versuchsaufbau .34 2.5 Ablauf der Testung .36 2.6 Erhobene Daten und Datenverarbeitung .39 2.7 Statistische Methoden .40 2.8 Materialliste .41 3 Ergebnisse .43 3.1 Monocorticale versus bicorticale Verschraubung von 4- Loch-Reihenplatten .43 I 3.2 4-Loch-Reihenplatte versus 6-Loch-Gitterplatte .44 3.3 6-Loch-Gitterplatte versus 8-Loch-Gitterplatte .45 3.4 8-Loch-Gitterplatte mit 4 Schrauben versus 8-Loch- Gitterplatte mit 8 Schrauben .46 3.5 Auswertung der normalisierten Werte .47 3.6 Zusammenfassung der Ergebnisse .48 4 Diskussion .50 4.1 Auswahl geeigneter Prüfkörper .50 4.2 Frakturmodell .51 4.2.1 Statistische Vorteile des Frakturmodells durch die Verwendung von normalisierten Werten .52 4.3 Versuchsaufbau .53 4.4 Statistik .53 4.5 Aufgetretene Versagensmechanismen .54 4.6 Diskussion der Ergebnisse .57 4.6.1 Monocorticale vs. bicorticale Verschraubung winkelstabiler Reihenplatten .57 4.6.2 Vergleich von 2D-Reihenplatten und 3DGitterplatten .58 4.6.3 Vergleich von 8-Loch-Gitterplatten in Verschraubung mit 4 bzw. mit 8 Schrauben .60 4.7 Ausblick .61 4.8 Limitierungen dieser Arbeit .63 5 Zusammenfassung .64 6 Literaturverzeichnis .66 7 Anhang .70 N2 - 1 Introduction .1 1.1 Plate osteosynthesis .1 1.1.1 Fracture healing .1 1.1.2 History of plate osteosynthesis .4 1.2 Angular stability .8 1.2.1 principles of angular stability .10 1.3 Anatomy and biomechanics of the hand .14 1.4 Fractures of metacarpals and phalanges .17 1.4.1 Epidemiology .17 1.4.2 Classification of metacarpal fractures .18 1.4.3 Therapy of metacarpal fractures .20 1.4.3.1 Non - operative therapy .21 1.4.3.2 Operative therapy .23 1.4.3.3 Functional treatment .26 1.4.4 Complications .27 1.5 Goals of this study .29 2 Material and methods .31 2.1 Specimen .31 2.2 Tested implants .32 2.3 Test preparations .33 2.4 Setting .34 2.5 Testing .36 2.6 Gathered data and data analysis .39 2.7 Statistics .40 2.8 List of equipment .41 3 Results .43 3.1 Monocortical versus bicortical fixation of two dimensional locking plates .43 3.2 4-hole-2D versus 6-hole-3D plates .44 3.3 6-hole-3D plate versus 8-hole-3D plate .45 3.4 8-hole-3D plate with 4 locking screws versus 8-hole-3D plate with 8 locking screws .46 3.5 Analysis of normalized results .47 3.6 Summary of results .48 4 Discussion .50 4.1 Selection of appropriate specimen .50 4.2 Fracture modell .51 4.2.1 Advantages regarding statistics through the use of normalized values .52 4.3 Test Setting .53 4.4 Statistics .53 4.5 Modes of failure .54 4.6 Discussion of results .57 4.6.1 Monocortical vs. bicortical fixation of locking plates .57 4.6.2 Comparison of 2D and 3D locking plates .58 4.6.3 8-hole 3D plates with 8 screws vs. 8 hole 3D plates with 4 screws .60 4.7 Perspective .61 4.8 Limitiations of this study .63 5 Summary .64 6 Literature .66 7 Appendix .70 KW - Osteosynthese KW - Plattenosteosynthese KW - Handchirurgie KW - osteosynthesis KW - locking plates KW - metacarpal fractures Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-54007 ER - TY - THES A1 - Rey, Katharina T1 - Knochenreaktion nach Osteosynthese mit einer Kohlenstofffaser-PEEK Platte T1 - Bone reaction after osteosynthesis with a carbon fibre PEEK plate N2 - Die Snake Plate ist ein im Composite Flow Moulding Verfahren (CFM) aus endlosen Kohlenstofffasern und PEEK (CF/P) hergestelltes neues Implantat für die Frakturbehandlung. Besondere Merkmale sind hohe Formbeständigkeit, konvergierende, winkelstabile Schrauben sowie eine völlige Strahlendurchlässigkeit. Integrierte Tantalfäden machen die Platte artefaktfrei radiologisch sichtbar. Ziel dieser in vivo Studie war ein Vergleich des Heilungsverlaufes zwischen der 7-Loch Snake Plate und der bereits klinische verwendeten 7-Loch LCP. Die Tiere wurden in 2 Gruppen (n=6) zufällig aufgeteilt. Eine 0,6mm breite Osteotomie der rechten Schafstibia wurde mit der Snake Plate bzw. der LCP und 6 winkelstabilen Schrauben versorgt. Zur postoperativen Fluoreszenzmarkierung des Kalzifizierungsprozesses erhielten die Tiere in der 5. Woche Xylenol Orange und in der 7. Woche Calcein Grün. Die Makrophagen/Histiozyten- Schichtdicke des Weichteilgewebes wurde computerunterstützt semiquantitativ vermessen. Eine qualitative Beurteilung der Gewebszonen und der Sentinel Lymphknoten folgte. Der Kalzifizierungsprozess in der Osteotomiezone wurde computerunterstützt quantitativ erfasst und qualitativ beurteilt. Die Osseointegration der Schrauben wurde quantifiziert, indem der prozentuale direkte Schrauben-Knochen-Kontakt computerunterstützt berechnet wurde. Die Knochenumbauvorgänge im Bereich des Schrauben-Knochen-Interfaces wurden erfasst, indem die Anzahl der Osteone gezählt und ihre Tiefe in den Bereich der Kortikalis errechnet wurde. Es ergaben sich zwischen den Gruppen hinsichtlich der semiquantitativen Ausmessung der Makrophagen-Histiozyten-Schichtdicke keine Unterschiede. Die zelluläre Zusammensetzung im plattennahen Weichteilgewebe zeigte keine Unterschiede. Abriebpartikel wurden in den Sentinel-Lymphknoten nicht gefunden. Zwischen den Gruppen zeigten sich keine Unterschiede im Ausmaß des kalzifizierten Kallusgewebes im Osteotomiespalt. Die knöcherne Überbrückung der Frakturzone war plattennah weiter fortgeschritten als plattenfern. Die qualitative Beurteilung war unauffällig und in beiden Gruppen ähnlich weit fortgeschritten. In der Beurteilung des Knochenumbauprozesses konnten zwischen den beiden Gruppen keine Unterschiede gefunden werden. Auch im zeitlichen Verlauf der Heilung zeigten sich in beiden Gruppen keine Unterschiede. Die Titan-Schrauben wiesen eine signifikant höhere direkte Knochen-Kontakt Zone auf als die PEEK-Schrauben. Im Allgemeinen zeigt sich das Gewebe sowohl im Kontakt mit den Kohlefaserimplantaten als auch mit den Titanimplantaten reizarm und ohne die bei Entzündungen üblichen zellulären Reaktionen. Die biologischen und mechanischen Bedingungen der beiden Plattenarten müssen offensichtlich ähnlich sein, da die Frakturheilung in beiden Gruppen gut fortgeschritten war. Der geringere direkte Knochenanteil der PEEK-Schraube ist wahrscheinlich materialbedingt. Es ist bekannt, dass Knochenzellen sich direkt auf Titanmaterialien ablagern können, wodurch das Einwachsverhalten in den Knochen begünstigt werden kann. Einen Einfluss der unterschiedlichen Biokompatibilitäten der Implantatmaterialien auf die Knochenumbauprozesse im Bereich des Schrauben-Knochen-Interfaces konnte nicht nachgewiesen werden. Die Verbesserung des Interface zwischen Knochen und Implantat ist immer noch ein ungelöstes Problem. Ziel ist es, eine geeignete Umgebung zu schaffen, durch die das natürliche Potential des Knochens zur Regeneration stimuliert und maximiert werden kann. In weiteren Studien sollte untersucht werden, ob die Biokompatibilität der neu entwickelten PEEK-Schraube durch unterschiedliche Oberflächen-behandlungen, beispielsweise mit Titan, erhöht werden kann und daraus eine bessere Osseointegration erzielt werden könnte. N2 - The Snake Plate, produced out of carbon fibre and PEEK (CF/P) by using the composite flow moulding method (CFM),is a new implant for fracture treatment. The special features are resistance to deformation, converging locking screws and radiolucency. The Radiological visualization free of artefacts is made possible by integrated tantal threads. The goal of this “in vivo study” was to compare the process of recovery using the seven-hole Snake Plate to the actual in clinical use seven-hole LCP. The animals were randomly divided into two groups (n=6). A 0.6 mm wide osteotomy of the right tibia was stabilized with the snake plate for the one and LCPs for the other group. All were fixed with six locking screws. The animals received Xylenol orange in week five and Calcein green in week seven as fluorescent dye in order to mark the postsurgical calcification process. The thickness of the macrophage/histiocyte layer of the soft part tissue was measured in a computer-assisted and semi-quantitative way. It was followed by a qualitative assessment of the different layers of the tissue and of the sentinel lymphatic nodes. The process of calcification in the osteotomy area was also measured computer-assisted and was qualitative assessed. The osseointegration of the screws was quantified by a computer-assisted calculation of the percentage of direct contact between screws and bone. The osteogenetic processes in the interface between screws and bone were measured by counting the osteones and calculating their depth in the area of the corticalis. Neither the semi-quantitative measurements of the macrophage/histiocyte layers nor the cellular composition of the soft part tissues near the plate showed different results for the two groups. No particles of attrition were found in the sentinel lymphatic nodes. The two groups did not show any differences concerning the semi-quantitative measurements of the macrophage/histiocyte layers. There was also no difference regarding the amount of calcified callus in the gap of osteotomy. The osseous bridging of the fracture zone was further advanced near the plate. The qualitative assessment was not unusual and the progress was comparable in both groups. There were no differences between the two groups concerning assessment of the osteogenetic processes. The chronological process of the consolidation did not show any differences between the two groups either. The area of direct bone contact was significantly higher with the titanium screws than with the PEEK-screws. In general the tissue was hardly irritable in contact with the carbon fibre implants as well as with the titanium implants. Neither were there any cellular reactions typical for inflammations. The biological and mechanical conditions of the two types of plates are apparently similar, as the healing of the fracture was advanced in both groups. The low direct bone contact of the PEEK-screws is probably associated with the material. It is well-known that osteocytes can accumulate on titanium, a fact which may favour the growing-in of the material into the bone. An influence of the different biological compatibilities of the materials of the implantations on the osteogenetic processes in the interface between screws and bone could not be proven. The improvement of the interface between bone and implant is still an unsolved problem. The aim is to create a suitable environment for stimulating and maximizing the natural regenerative potential of the bone. Further studies should be carried out in order to find out whether the biological compatibility of the new PEEK-screw can be improved by treating its surface with titanium for example. This might lead to an improvement in osseointegration. KW - Osteosynthese KW - PEEK KW - Fixateur interne KW - Osteotomie KW - bone healing KW - osteosynthesis KW - PEEK KW - LCP KW - bone reaction Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-26828 ER -