TY - JOUR A1 - Boelch, Sebastian P. A1 - Gurok, Anna A1 - Gilbert, Fabian A1 - Weißenberger, Manuel A1 - Rudert, Maximilian A1 - Barthel, Thomas A1 - Reppenhagen, Stephan T1 - Why compromise the patella? Five-year follow-up results of medial patellofemoral ligament reconstruction with soft tissue patellar fixation JF - International Orthopaedics N2 - Purpose This study investigates the redislocation rate and functional outcome at a minimum follow-up of five years after medial patellofemoral ligament (MPFL) reconstruction with soft tissue patellar fixation for patella instability. Methods Patients were retrospectively identified and knees were evaluated for trochlea dysplasia according to Dejour, for presence of patella alta and for presence of cartilage lesion at surgery. At a minimum follow-up of five years, information about an incident of redislocation was obtained. Kujala, Lysholm, and Tegner questionnaires as well as range of motion were used to measure functional outcome. Results Eighty-nine knees were included. Follow-up rate for redislocation was 79.8% and for functional outcome 58.4%. After a mean follow-up of 5.8 years, the redislocation rate was 5.6%. There was significant improvement of the Kujala score (68.8 to 88.2, p = 0.000) and of the Lysholm score (71.3 to 88.4, p = 0.000). Range of motion at follow-up was 149.0° (115–165). 77.5% of the knees had patella alta and 52.9% trochlear dysplasia types B, C, or D. Patellar cartilage legions were present in 54.2%. Redislocations occurred in knees with trochlear dysplasia type C in combination with patella alta. Conclusion MPFL reconstruction with soft tissue patellar fixation leads to significant improvement of knee function and low midterm redislocation rate. Patients with high-grade trochlear dysplasia should be considered for additional osseous correction. KW - MPFL KW - medial patellofemoral ligament KW - patella instability KW - patella dislocation KW - trochlear dysplasia KW - patella alta Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235751 SN - 0341-2695 VL - 45 ER - TY - JOUR A1 - Boelch, Sebastian P. A1 - Roth, Magnus A1 - Arnholdt, Joerg A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Synovial fluid aspiration should not be routinely performed during the two-stage exchange of the knee JF - BioMed Research International N2 - Purpose. Detection of infection persistence during the two-stage exchange of the knee for periprosthetic joint infection is challenging. Synovial fluid culture (SFC) and synovial white blood cell count (SWBCC) before joint reimplantation are widespread diagnostic means for this indication. The sensitivity and specificity of SFC and of SWBCC for infection persistence before planned reimplantation were evaluated. Methods. 94 two-stage exchanges of the knee with synovial fluid aspiration performed after a drug holiday of at least 14 days and before reimplantation or spacer exchange (planned reimplantation) were retrospectively analyzed. Only cases with at least 3 intraoperative samples at planned reimplantation were included. SFC and SWBCC were compared to pathogen detection (SFC\(_{(culture)}\)/SWBCC\(_{(culture)}\) and to histopathological signs of infection persistence (SFC\(_{(histo)}\)/SWBCC\(_{(histo)}\) from intraoperative samples at planned reimplantation. For SFC, the sensitivity and specificity were calculated. For SWBCC, the optimal cut-off value with its sensitivity and specificity was calculated with the Youden-Index. Results. Sensitivity and specificity of SFC\(_{(culture)}\) were 0.0% and 98.9%. Sensitivity and specificity of SFC\(_{(histo)}\) were 3.4% and 100%. The optimal cut-off value for SWBCC\(_{(culture)}\) was 4450 cells/μl with a sensitivity of 50.0% and a specificity of 86.5%. The optimal cut-off value for SWBCC\(_{(histo)}\) was 3250 cells/μl with a sensitivity of 35.7% and a specificity of 92.9%. Conclusion. The detection of infection persistence remains challenging and a consented approach is lacking. The results do not warrant the routine performance of SFC during the two-stage exchange at the knee. SWBCC can be used to confirm infection persistence at high cut-offs, but they only occur in few patients and are therefore inappropriate for the routine use. KW - knee KW - two-stage exchange KW - Synovial Fluid Aspiration Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176800 VL - 2018 IS - 6720712 ER - TY - JOUR A1 - Eidmann, Annette A1 - Ewald, Andrea A1 - Boelch, Sebastian P. A1 - Rudert, Maximilian A1 - Holzapfel, Boris M. A1 - Stratos, Ioannis T1 - In vitro evaluation of antibacterial efficacy of vancomycin-loaded suture tapes and cerclage wires JF - Journal of Materials Science: Materials in Medicine N2 - Usage of implants containing antibiotic agents has been a common strategy to prevent implant related infections in orthopedic surgery. Unfortunately, most implants with microbial repellent properties are characterized by accessibility limitations during daily clinical practice. Aim of this in vitro study was to investigate whether suture tapes and cerclage wires, which were treated with vancomycin, show a sustainable antibacterial activity. For this purpose, we used 24 stainless steel wire cerclages and 24 ultra-high molecular weight polyethylene and polyester suture tape test bodies. The test bodies were incubated for 30 min. in 100 mg/ml vancomycin solution or equivalent volumes of 0.9% NaCl. After measuring the initial solution uptake of the test bodies, antibacterial efficacy via agar diffusion test with Staphylococcus aureus and vancomycin elution tests were performed 1, 2, 3, and 6 days after incubation. Vancomycin-loaded tapes as well as vancomycin-loaded cerclage wires demonstrated increased bacterial growth inhibition when compared to NaCl-treated controls. Vancomycin-loaded tapes showed an additional twofold and eightfold increase of bacterial growth inhibition compared to vancomycin-loaded wires at day 1 and 2, respectively. Elution tests at day 1 revealed high levels of vancomycin concentration in vancomycin loaded tapes and wires. Additionally, the concentration in vancomycin loaded tapes was 14-fold higher when compared to vancomycin loaded wires. Incubating suture tapes and cerclage wires in vancomycin solution showed a good short-term antibacterial activity compared to controls. Considering the ease of vancomycin application on suture tapes or wires, our method could represent an attractive therapeutic strategy in biofilm prevention in orthopedic surgery. KW - anti-bacterial agents / administration & dosage KW - anti-bacterial agents / chemistry KW - bone wires KW - drug liberation KW - materials testing KW - anti-bacterial agents / pharmacology KW - biocompatible Materials KW - prostheses and implants KW - Staphylococcus aureus / drug effects KW - sutures KW - Vancomycin / administration & dosage KW - Vancomycin / chemistry KW - Vancomycin / pharmacology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260089 VL - 32 IS - 4 ER - TY - JOUR A1 - Boelch, Sebastian P. A1 - Rueckl, Kilian A1 - Fuchs, Clara A1 - Jordan, Martin A1 - Knauer, Markus A1 - Steinert, Andre A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Comparison of elution characteristics and compressive strength of biantibiotic-loaded PMMA bone cement for spacers: Copal\(^®\) spacem with gentamicin and vancomycin versus Palacos\(^®\) R+G with vancomycin JF - BioMed Research International N2 - Purpose. Copal\(^®\) spacem is a new PMMA bone cement for fabricating spacers. This study compares elution of gentamicin, elution of vancomycin, and compressive strength of Copal\(^®\) spacem and of Palacos\(^®\) R+G at different vancomycin loadings in the powder of the cements. We hypothesized that antibiotic elution of Copal\(^®\) spacem is superior at comparable compressive strength. Methods. Compression test specimens were fabricated using Copal\(^®\) spacem manually loaded with 0.5 g gentamicin and additionally 2 g, 4 g, and 6 g of vancomycin per 40 g of cement powder (COP specimens) and using 0.5 g gentamicin premixed Palacos\(^®\) R+G manually loaded with 2 g, 4 g, and 6 g of vancomycin per 40 g of cement powder (PAL specimens). These specimens were used for determination of gentamicin and vancomycin elution (in fetal calf serum, at 22°C) and for determination of compressive strength both prior and following the elution tests. Results. Cumulative gentamicin concentrations (p < 0.005) and gentamicin concentration after 28 days (p ≤ 0.043) were significantly lower for COP specimens compared to PAL specimens. Cumulative vancomycin concentrations were significantly higher (p ≤ 0.043) for COP specimens after the second day. Vancomycin concentrations after 28 days were not significantly higher for the Copal specimens loaded with 2 g and 4 g of vancomycin. Compressive strength was not significantly different between COP specimens and PAL specimens before elution tests. Compressive strength after the elution tests was significantly lower (p = 0.005) for COP specimens loaded with 2 g of vancomycin. Conclusion. We could not demonstrate consistent superior antibiotic elution from Copal\(^®\) spacem compared to Palacos\(^®\) R+G for fabricating gentamicin and vancomycin loaded spacers. The results do not favor Copal\(^®\) spacem over Palacos\(^®\) R+G for the use as a gentamicin and vancomycin biantibiotic-loaded spacer. KW - Copal\(^®\) spacem KW - PMMA bone cement KW - elution KW - compressive strength Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177435 VL - 2018 IS - 4323518 ER -